HomeMy WebLinkAboutWORKSHEETVolumetric Con Dispenser Mix Des'- i Worksheet OWNER Mobil Crete Technologies Unit Serial # N91-83R YOUR MIX DESIGN (This sheet must be filled out for each mix design) r 9 — Q MIX DESIGN I Date F 10/16/2015—� (max 8 characters) Materials of one cubic yard: Cement F-600—j LBS. F-101161o7 Cement Discharge Speed 44 Counts per Bag of Cement (1n Percent) Cement 6.4 BAGS 1.99 Cubic Yard Discharge Time (Minute) Aggregate Pounds of Aggregate Name # Desired Aggregate Name Aggregate (enter 1, 2, 3, or4) 1 Pea Rock Aggregate 1 F-2!1 Ortona Sand r1744 � 2 Ortona Sand Aggregate 2 Pea Rock r900'1 3 Rock #67 4 0 Color h-- �OUNCES Low, Mid, or High Sys Dilution Oz/bag Admix # 1 Admix # 2 Admix # 3 (Mid Range available on 130, 150, & 200 Series units only) 1. Determine the count per cubic yard. Fiber Chopper Pounds per Yard SCANNED BY St. Lucie Count% DF.QC�vF.oeE OCT 3 0 RECD 6.4 bags/cubic yard x 44 counts per bag = 281 count per cubic yard. 2. AGGREGATE 1: Divide the lbs. of fine aggregate per cubic yard by the count per cubic yard. 1744 lbs. fine aggregate divided by 281 counts per cu. yd = 6.22 lbs. per count. GATE SETTING (from graph) 3.5 3. AGGREGATE 2: Divide the lbs. of coarse aggregate per cubic yard by the count per cubic yard. 900 lbs. coarse aggregate divided by 281 counts per cu. yd.= 3.21 lbs. per count. GATE SETTING (from graph) 2.7 Description 4000 Total_ _ _ _281 Counts / Cubic Yard Cement 2.14 IbsJ Count Dial —Aggregate-1— = 6.22.lbs./ Count_ _ Setting OzlMin n....ro—f- 1- 1 14 M. /. r--* AA...:.. II A _ =0n^0 n n *Water 2.49 IbsJ Count Admix # 2 ERROR 0.0 Aggregate 1 Gate 3.5 Admix # 3 ERROR 0.0 Aggregate 2 Gate 2.7 Color #DIV/01 0.0 Water Meter 42 Fiber Chopper #DIV/01 0 At this point we recommend that you run a 1/4 yard yield test. You must have a box that is 1/4 cubic yard. You can build one with internal dimensions of 36" x 36" x 9". You start the unit producing concrete. Stop both the conveyor and mixer at the same instant. Set the 1/4 cubic yard yield box under the discharge. Start the mixer and conveyor at the same time. Run the unit to the amount indicated for 114 cubic yard (1/4th of the meter count per cubic yard from step 1). Shut off the mixer and conveyor at the same instant. The box should be full. It may be necessary to adjust the aggregate gates slightly to adjust the yield. 1/4 Yard Count 70 If you have a water recording meter your lbs./Count will be approximately 1.0425. SRM 08-10 :, Volumetric Con" 'ate Dispenser Mix Des i Worksheet OWNER Mobil Crete Technologies Unit Serial # N91-85R YOUR MIX DESIGN (This sheet must be filled out for each mix design) MIX DESIGN 4000 "j Date I 10/16/2015 (maz 8 characters) Materials of one cubic yard: Cement ['600-7 LBS. j -f 60%-1Cement Discharge Speed 102 Counts per Bag of Cement (In Percent) Cement 6.4 BAGS 1.61 Cubic Yard Discharge Time (Minute) Aggregate Name 1 Pea Rock 2 Orions Sand 3 Rock #67 4 0 Aggregate # Desired (enter 1, 2, 3, or4) Aggregate 1 j-2--] Aggregate 2 Color F_____10UNCES Low, Mid, or High Sys Dilution Oz/bag Admix # 1 1 Admix # 2 Admix # 3 (Mid Range available on 130, 150. & 200 Series units only) 1. Determine the count per cubic yard. Aggregate Name Ortona Sand Pounds of Aggregate j 1V97 Pea Rock 900-1 Fiber Chopper �-1 Pounds per 6.4 bags/cubic yard x 102 counts per bag = YrdDLS- OCT 3 0 RECD 649 count per cubic yard. 2. AGGREGATE 1: Divide the lbs. of fine aggregate per cubic yard by the count per cubic yard. 1744 lbs. fine aggregate divided by 649 counts per cu. yd = 2.69 lbs. per count. GATE SETTING (from graph) 5.2 3. AGGREGATE 2: Divide the lbs. of coarse aggregate per cubic yard by the count per cubic yard. 900 lbs. coarse aggregate divided by 649 counts per cu. yd.= 1.39 lbs. per count. GATE SETTING (from graph) 2.9 Description 4000 -----Total 649 Counts Cubic Yard Cement 0.93 lbs./ Count Dial - .aggregate_= _�saios.1-t ouM 'Water 0.87 lbs./ Count Aggregate 1 Gate 5.2 Aggregate 2 Gate 2.9 Water Meter _ 42 Oz1Min Admix # 2 ERROR 0.0 Admix # 3 ERROR 0.0 Color #DIV/0! 0.0 Fiber Chopper #DIV101 0 At this point we recommend that you run a 114 yard yield test. You must have a box that is 1/4 cubic yard. You can build one with internal dimensions of 36" x 36" x 9". You start the unit producing concrete. Stop both the conveyor and mixer at the same instant. Set the 1/4 cubic yard yield box under the discharge. Start the mixer and conveyor at the same time. Run the unit to the amount indicated for 1/4 cubic yard (1/4th of the meter count per cubic yard from step 1). Shut off the mixer and conveyor at the same instant. The box should be full. It may be necessary to adjust the aggregate gates slightly to adjust the yield. 1/4 Yard Count 162 If you have a water recording meter your lbs./Count will be approximately 1.0425. SRM 08-10