Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTRECrC SEP 14 2015 September 4, 2015 SCANNED BY Luke Price St. Lucie County SBA Communications Corporation 9900 WestPoint Drive, Suite 116 Indianapolis, IN 46256 (205) 908-5792 Subject: Structural Analysis Report T-Mobile Designation: Site Number: Site Name: SBA Communications Corporation Designation: Site Number: Site Name: Application Number: Engineering Firm Designation: Site Data: Dear Luke Price, B+T Group Project Number: JPB+T GRP B+T Group 1717 S. Boulder, Suite 300 Tulsa, OK 74119 (918)587-4630 btwo@btgrp.com A2P0309M A2P0309M FL17050-A TC SR-70 22456, v2 100926.001.01 24880 Okeechobee Road, Ft. Pierce, St. Lucie County, FL 34945 Latitude 27° 22' 35.72", Longitude -80' 35' 16.13" 250 Foot - Self Support Tower g+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foun n, (rjppyad case, to be: Existing + Reserved + Proposed Equipment icient Capacity Note: See Table 1 and Table 2 for the proposed and existing 1 din e i Tower: 69.2% Foundation: 47.0% This analysis has been performed in accordance with the 2014 Florida Building Code 5tn Edition based upon an ultimate 3-second gust wind speed of 151 mph converted to a nominal 3-second gust wind speed of 117 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. All equipment proposed in this report.shall be installed .in accordance with the attached drawings for the determined available structural capacity to be effective. --- - --------- ------ We a-B+TGroup-appreciaate-the opportb6lty-ofproviditTd'o=ntihbirrgpiofessionat sery ces toyouand BA- =-- - Communications Corporation. If you have any questions or need further assistance on this orany other projects please give us a call. Respectfully submitted by: B+T Engineering, Inc. Brandon Sevier, E.I. Project Engineer John W. Kelly, P.E., S.E. Engineer of Record COA:27496 Expires:2/28/2017 �W. KEZ�y o. 6 4 OF r�rnnmatta� "lr tnxTower Report - version 6.1.4.1 i 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 — Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations September 4, 2015 Site No. FL17050-A Page 2 tnxTower Report - version 6.1.4.1 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL 1) INTRODUCTION September 4, 2015 Site No. FL17050-A Page 3 This tower is a 250 ft. Self -Support tower designed by Central Tower, Inc. in September of 2003. The tower was originally designed for a wind speed of 120 mph per TIA/EIA-222-F. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 117 mph with no ice and 60 mph under service loads, exposure category C with topographic category 1 and crest height of 0 feet. Table 1 - Final T-Mobile Loading Antenna and Cable Information Mounting Level (ft), Center, Lme Elevation O 9 Number99] Of Antennas j Antenna i Manufacturer i I Antenna Model Number of Feed Lines Feed Line Size (in) Note 3 Andrew DBXNH-6565B-A2M 3 1.24 T-Mobile Proposed 6 Cellmax Tech. CMA-BDHH/6520/EO-8 3 Nokia FRIE 248.0 248.0 6 1-5/8 T-Mobile Existing 3 Nokia FRIG 3 Nokia FXFB 3 Raycap ASU9338TYP0l 3 -- Sector Mount Table 2 - Existina Antenna and Cable Information Mounting Level (ft),' Center Line'of Elevation - Numberd Antennas { Antenna i Manufacturer Antenna Model j Number of Feed Lines' Feb Line Size (in) Note ; T-Mobile 3 Cellmax Tech. CMA-BDHH/6520/EO-8 3 1.584 To Be Removed 6 Cellmax Tech. CMA-BDHH/6520/EO-8 248.0 248.0 3 Nokia FRIE 3 Nokia FRIG - 6 1-5/8 T-Mobile Existing_ - 3- Nokia FXFB- - ASU9338TYP01 Mount__ - tnxTower Report - version 6.1.4.1 A N l 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL Table 3 - Desiqn Antenna and Cable Information September 4, 2015 Site No. FL17050-A Page 4 { Mounting, Center. Le - I Elevation) I r Numbe 1 of AntennasI Anten Manufacturer , Antenna Model Number of Feed Lines `. Feedlinena , LineLevel(ft)� S¢e (in (ft) J j 250 250 12 Decibel DB982F105E-M 12 1-5/8 1 Generic 13' Gate Mounts/T-Arms 225 225 9 Decibel DB982F105E-M 9 1-5/8 1 Generic 13' Gate Mounts/T-Arms 220 220 9 Decibel DB982F105E-M 9 1-5/8 1 Generic 13' Gate Mounts/T-Arms 150 150 2 Generic HP6-S7W 2 7/8 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document Remarks I Reference 11 Source Tower Data Tower Drawing by Central Tower Inc., Date:09/1012003 SBA Project No. SS1366 Foundation Data Foundation Drawing by Central Tower Inc., Date:0911012003 SBA Project No. SS1366 Soil Properties I Morrison Hershfield, I Date:08/01/2003 SBA Existing Loading I SBA Site Summary Form, Site Id: FL17050-A Date:06/23/2015 SBA Proposed Loading T-Mobile Application# 22456, v2 Date:09102/2015 SBA 3.1) Analysis Method tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3)- The -configuration of antennas, -transmission cables; mounts and other appurtenances are as - - - - - specified in Tables 1 and 2 and the referenced drawings. A\ KAn,mf araa and wainhM ara aeenmerl hacari nn nhnfnnrnnhc nrnvir-iu ttoit aetaiis were not provtoea. tson size. by the same manufacturer. This analysis may be affected if any assumptions are not valid or have been made in error. B+T Group should be notified to determine the effect on the structural integrity of the tower. tnxTower Report - version 6.1.4.1 / p A 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL 4) ANALYSIS RESULTS Table 5 - Section Caoacitv (Summary) September 4, 2015 Site No. FL17050-A Page 5 $ecttort No i tie vaLon ft ( ). -" i Com orient Type P _ - Size .Y -i Critical 1 Element% P (� SF P allovi (iQ / Gapacit7% Y 'Pass I Fail T1 250-240 Leg 21/4 1 -21.391 130.399 16.4 Pass T2 240-220 Leg 2 1/2 28 -82.625 167.374 49.4 Pass T3 220-200 Leg 3 1/2 73 -106.954 256.230 41.7 Pass T4 200 - 180 Leg 4 94 -135.211 378.448 35.7 Pass T5 180-160 Leg 41/4 115 -163.640 447.281 36.6 Pass T6 160 -140 Leg 4 112 136 -193.191 521.096 37.1 Pass T7 140 -120 Leg 4 314 157 -224.217 599.797 37.4 Pass T8 120 -100 Leg 4 314 178 -257.162 599.797 42.9 Pass T9 100 - 80 Leg 5 199 -292.242 683.313 42.8 Pass T10 80-60 'Leg 51/4 220 -329.438 771.566 42.7 Pass T11 60-40 Leg 5 112 241 -369.358 864.519 42.7 Pass T12 40 - 20 Leg 5 3/4 262 -411.623 962.128 42.8 42.8 (b) Pass T13 20 - 0 Leg 5 314 283 455.600 962.128 47.4 Pass T1 250- 240 Diagonal 1 15 -4.228 13.997 30.2 Pass T2 240-220 Diagonal 1118 42 -5.769 18.668 30.9 Pass T3 220-200 Diagonal L2x2x1/4 92 -4.569 15.422 29.6 37.9 (b) Pass T4 200 -180 Diagonal L2 1/2x2 1/2x3/16 101 -4.381 14.728 29.7 42.4 (b) Pass T5 180-160 Diagonal 1-21/2x21/2x1/4 122 -5.121 15.499 33.0 37.2 (b) Pass T6 160-140 Diagonal L21/2x21/2x5/16 143 -6.003 14.284 42.0 Pass T7 140 - 120 Diagonal L3x3xl/4 164 -7.172 16.000 44.8 47.7 (b) Pass TS 120-100 Diagonal L3x3x3/8 185 -8.340 18.227 1 45.8 Pass T9 100 - 80 Diagonal L3 1/2x3 1/2x5/16 206 -9.765 20.218 48.3 Pass T10 80- 60 Diagonal L4x4x1/4 227 -11.248 20.530 54.8 63.5 (b) Pass T11 60-40 Diagonal L4x4x3/8 248 -12.943 24.883 52.0 54.1 (b) Pass T12 40-20 Diagonal L5x5x5/16 269 -14.796 35.576 41.6 62.5 (b) Pass T13 20 - 0 Diagonal L5x5x5/l6 290 -16.429 30.474 53.9 Pass Tt 250 - 240 Top Girt 1 5 -0.065 10.727 0.6 Pass -Jbip Girt - 32 -1.5 1 - 16.396 - 9.3 - Pass _ T- 250--240-- --- .Bottom. Girt- 1- - B. -1.196 10.727 11.2 _ .Pass T2 240 - 220 Bottom Girt 1 1/8 36 -0.218 16.396 1.3 Pass Summary Leg (T2) 49.4 Pass Diagonal (T13) 69.2 Pass Top Girt (T2) 9.3 Pass Bottom Girt (T1) 11.2 Pass Bolt Checks 69.2 Pass RATING = 69.2 Pass tnxTower Report - version 6.1.4.1 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL Tahle 6 - Tower Component Stresses vs. Canacitv September 4, 2015 Site No. FL17050-A Page 6 Notes , " Component . 61 Elevation (ft)' ; %Capacity Pass /Fail 1I Anchor Rods I Base J 47.6 Pass 1,2 1 Base Foundation (Structure) I Base 1 47.0 Pass 1,2 IBase Foundation (Soil Interaction) Base 1 42.6 Pass Structure Rating (max from all components) 69:2% Notes' 1) See additional documentation in "Appendix C— Additional Calculations" for calculations supporting the % capacity consumed. 2) Two foundation drawings were provided. The worst capacity was reported in this analysis. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing and proposed loads. No modifications are required at this time. tnxTower Report - version 6.1.4.1 APPENDIX A TNXTOWER OUTPUT D y N N no N N N C �p6 on J � N @ on 4 on C rc h F - � a d @ tt ot � c y s a � to g 0 p g E 3 250A R 240OIt 220 0 It 2000It 180.0 R DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION Lightning Ron W x 4' on 6' Pole (E) 255 FRIE (E) 248 seobe(E) 251 FRIE(E) 248 (2)CMA-BDHW6520R08 .1 Mount Pipe(E) 248 ASU9338r l(E) 248 muic BTYP01(E) 248 ((2) MA-BOHW65ii01E041 w/Mount 248 ASU!)ntl P01(E) 248 DBXNHE5658- 2Mw/Mount Pipe (P) 248 (2)CMA-BOHH/6KoIEM w/Mount Pipe(E) 248 DBXNHBS65B-A Mw/Mount Pipe (P) 248 FXFB(E) 248 FXFB IE) 248 D9XN11E55519-AeA w/Mount Pipe (P) 248 FXFBIE) 248 FRIG (E) 248 Se=r Mount ISM I (E) 248 FRIG (E) 248 Side Ughting(E) 1125.5 FRIG (E) 1248 Side UghOng (E)1 125.5 FRIE(E) 1248 1 Bide UghtIng(E) 125.5 SYMBOL LIST MARK SIZE MARK ISIZE A 3@3AB333 160.0 ft TOWER DESIGN NOTES 1. Tower is located in Saint Lucie County, Florida. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 117 mph basic wind In accordance with the TIA-222-G Standard. 1a0o rtrt 4. Deflections are based upon a 60 mph wind. 5. Tower Structure Class II. 6. Topographic Category 1 with Crest Height of 0.000 ft 7. TOWER RATING: 69.2% 120.0 It 100.0 ft 80_0ft 60.0 ft ALL REACTIONS AREFACTORED MAX. CORNER REACTIONS AT BASE: 40.0 ft DOWN: 463 K SHEAR: 47 K 20A R AXIAL 93 K SHEAF MOMENT 79 K���y ` 9347 kip -It 0.0 ft TORQUE 51 kip-ft REACTIONS - 117 mph WIND B+T Group �� lob: 100926.001.01 - TC SR-70, FL Site# FL 17050-A P,olex 1717 S Boulder Ave, Suite 300 B-T GRP Tulsa, OK 74119 Clap SBA Communications Corpore[io °fe"A1 br. B. Sevie Ayp'd: code' TIA-222-G °aht' 09I04/15 scale: NITS Phone: (918) 587-4630 Palh: Dw No. E-1 FAX: 918 295-0265 4 TIA-222-G - 117 mph Exposure C Leg Capacity Leg Compression (K) 15M 1000 311V <. minimum L Mammum-> -SW -Imm -IOU. 250. 60.000 240.00 I I I I 40.000 I I I 1 1 1 I I I I I I I I I I I 1 1 1 1 I I I I I I I I I I I 1 I I I I I I I I I I I 120.00 F 7 -F I --_ I I I 0.000 1 I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 20000 I _� _L_J _L I I I I _L_1 _I _1 I i _I _L I I I _L _L I I I �_� _L_� I I I I _� _L_4 _I I I 00.000 1 I I I I I I I I I I I I I 1 I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 180.000 I I I I 1 -F-y I I + -F-i -I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 11 160.00 I I I 1 I I I 1 1 I I I I 1 I I 1 1 I I I I I I I I I I I I I I I I I I I I I I 1 1 I I 160.000 - r`r-i- -i - I I I I __r-r-- 1 1 1 I I I I 1 I I I i I 140.00 I I I I 1 I I I i i i 1 I I I I I_ i t I I I I 1 I _LI�_L_ i I 1 i I I I 1 I I I I i _� I I I I _�L_LI 1ao.00a I I I I 1 I I I I I I I I I I I I I I C I I I I I I I I I I I I I I O I 1 I I V I I I R I20.00 uo.aoo 1__I i R I 1 1 1 I 1 1 1 1 I I I I I I I I I I I I I I I I I Lu 1 1 1 1 I I 1 I I I 1 I 1 I I ( 1 I 1 I 1 I I 1 100.00 1 1 I I 1 I 1 1 I I 1 I I I I I 1 1 l I 100.000 I I I I I I 1 I I I I r__I_ r_. _1__ 1 I I I __1__r_�__r_ I I I __r____ 1 i I I I I I I I I I I 1 1 1 1 1 1 1 I I I 1 l i I I I I 60.00 ___________ 1 _ --- _ ___ I 1 _ _ I 1 I I I I I 0.000 I I L 60.00 _ 0.000 I I I I I I I I I I I I I I 1 I I I I I I I I I I I d0 L_J_.I 1 I # 1 O 1 1 F I I I I 1 I I I I I I I I I I 1 I za. I 1 i I I i I i i i I I 1 i I I i I I i I I i 1 i i i I I I 1 1 i li 1 i I I 1 i 1 i i i i i 1 I i i t i o.aoo 0.06 l I 1 I I I I i I i 1 I I I I I I i i I i I I 1 1 1 1 I 1 I I I I I I i i 1 I I I 1 I I I I I I 600 lsnn lnnu firm <_Minimum -0 Mazimuma -500 .1000 -16M B+T Group 1717 S Boulder Ave, Suite 300 BST GRP Tulsa, OK 74119 Phone: (918) 5874630 FAX: 918 295-0265 °b. 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) Pmi� C°`"b SBA Communications Co oratio ---by B. Sevie 'wad` Loue' TIA-222-G °meo 09/04/15 sale' NTS Path' c"'a N0 E-3 e C 0 d W TIA-222-G -117 mph Exposure C Maximum Values Vx ------------Vz Mx ------------ Mz Global Mast Shear (K) Global Mast Moment (kip-ft) ° 100 u 5000 10D 1 I I I I I I 1 I 1 I I I I I 1 I I I I I I I I I I I I I I I 1 I I I I 1 I I I I I I 1 I 1 I I 1 I 1 1 I I I 1 I I I� I I I 1 I 1 I 1 I I I I I I 1 1 I I I I I I I I I I I I I I I I I •4 I 11 I I y I t 1 I I f I 1 I I I 1 7 I I I • I I I i I I 1 1 I I I I I I 1 1 I I I I I I I l I I 1 I I 1 I 1 I 1 I I I I I I I I I I 1 I I 1 I I I I I 1 I I I 1 I I I I I I I I -__I___ I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I I ; I i I 7 I I I I I 1 I 1 I I I I I II I I I I L I I I I I I I I I I I I •y I I I I I I I I I I I I I I I � I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I -------------- I I I 1 I I i I i I I I I I I I I I I I I I I I 1 I I I I I \I I r1 I I I I I 1 I �•\ I I I I I I I I I I I 1 I I I I I I I L ___I ___I___ I I I __ I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I 1 I I _1 _L _ _J 140 I I I I I 120 I I I I I 100 0.1 I I I I I I I 1 I I I I I I I 1 •\I I I I B+T Group j= 1717 S Boulder Ave, Suite 300 BST GRP Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 ab:100926.001.01- TC SR-70, FL Site# FL 17050-A pmi° Cnem SBA Communications Co oratio °awn by B. Sevie App°' code: TIA-222-G °ale:09104115 SEa1a NTS Pa°' °"'° N0 E4 TIA-222-G - Service - 60 mph Maximum Values C 0 Iti W Deflection (in) I 1 I I I I I I I I I I I 1 I 1 I I I I 1 i I I I I I 1 I I I I I I 1 I I I 1 1 I I I I I I I I I I I I I I I I I i I I I I I I I 11 I I I 1 I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I i 1 I 1 I 1 I I I I 1 I I I I I 1 I I I I I 1 I 1 1 I I I I I I I I I I i I Tilt (deg) Twist s 0.1 o.1s a ac r T T I , L_L _J_.1_L_I_ __I__1 -L-J__ __L_J__1__L_ -r7-r-r---1- -r-r---I-r-r-I- --I- r--r--I----r--I--r--r- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I _ ___I _ _I__I __I_____I J_ L_L__J_ 1_ L J_ __I -1__L_J-- __L_J__1__L_ I I I 11 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I i I I I I I I I -r-t t-r---1-7-r-r---I-r-r-r T-r--r-7----r-7--r--r- I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I r r I I I I I I I t I I i- I I I I I I I I A 1 ! I I I I 1 1 1 1 I I I I I I I I I I I I I 1 I 1 i I I I I I i 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I B+T Group Job: 100926.001.01- TC SR-70, FL Site# FL17050-A ea 1717 S Boulder Ave, Suite 300 c elntt. SB-222-G ni�ations Corporatio D. br. B. Sevie Aaad: a=+�ao Tulsa, OK 74119 twee: TIA-222-G Da�B'09I04/15 alale: NTS Phone: (916) 567�630 PaN:1D� ao. 1-5 FAX: 918 295-0265 B+T Group 0b:100926.001.01 - M SR-70, FL Site# FL17050-A Pf li r � 1717 S Boulder Ave, Suite 300 ear �rxa Tulsa, OK 74119 Glens SBA Communications Corporatio Drawn by B. Sevie A001 c e: TIA-222-G Deg: 09/O4/15 S-�' NTS Phone: (918)587-1630 PaN: re Dwe No. F 6 FAX: 918 295-0265 4 Rouen Flat Feed Line Distribution Chart 0' - 250' App In Face . - , - . App Out Face .„.„. T uss Leg 140.000 sva W c s i•� __y 2� _______ -------- --- cc 120000 ru _ r 100000 --- -- -- ---- -- -- -- -- - -- 80.000 80.000 20A00 --- -------- -------- --- Face B Face C 248000 _________________________ ____________ ________ ___ _________________________ ____________ ________ ___ _________________________ ___________a ________ ___ V W T _________________________ 125500 ---------------------- --- --------------- -- _________________________ __r ----------------- ___ 3 _________________________---- ._______-_________ B+T Group 1717 S Boulder Ave, Suite 300 BST GRP Tulsa, OK 74163 Phone: (918)587-4630 FAX: 918 295-0265 lob: 100926.001.01 - TIC SR-70, FL Site# FL17050-A F`iea SBA Communiw8ons Co oratio Drawn �'B. Sevia Appd: Cone: TIA-222-G Dale: 09/04/15 Sfata: NTS RaN: 0a9 Na. E-7 WxTower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 1 of 26 B+T Group 1717SBoulderAve, Suite 300 Project Date 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX (918) 295-0265 SBA Communications Corporation B. Sevier Tower Input Data The main tower is a 3x free. standing tower with an overall height of 250.000 ft above the ground line. The base of the tower is set at an elevation of 0.000 ft. above the ground line. The face width of the tower is 4.000 ft at the top and 25.000 ft at the base. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Saint Lucie County, Florida. Basic wind speed of 117 mph. Structure Class H. Exposure Category C. Topographic Category 1. Crest Height 0.000 ft. Deflections calculated using a wind speed of 60 mph. A non -linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in tower member design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) - - Add 113C;61>+W Combination- - O tions_ Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For KLr Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing -UseTIA-222-G Tension Splice Capacity Exemption Treat Feedline Bundles As Cylinder Use ASCE 10 X-Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in PEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check t� Poles Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets t=Tower Job 100926.001.01 - TC SR-70, FL (Site# FL17060-A) Page2 of 26 Project Date 08:51:59 09/04/15 $+T Group 1717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX- (918) 295-0265 SBA Communications Corporation B. Sevier Wind 180 Leg A Wind 90ce Leg C Z Leg B Face C Wind Normal Triangular Tower Tower Section Geometry Tower Tower Assembly Description Section Number Section Section Elevation Database Width of Length Sections R ft ft TI 250.000-240.000 4.000 1 10.000 T2 240.000-220.000 4.000 1 20.000 T3 220.000-200.000 4.000 1 20.000 T4 200.000-180.000 5.910 1 20.000 T5 180.000-160.000 7.820 1 20.000 T6 160.000-140.000 9.730 1 20.000 T7 140.000-120.000 11.640 1 20.000 'TB. 120.000100.000 13550 _ I _ 20.000 T9 100.000-80.000 15.460 l 20.000 T13 20.000-0.000 23.090 1 20.000 Tower Section Geomet cont'd -._ Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End ft ft Panels in in Tl 250.000-240.000 3.083 XBrace No No 4.500 4.500 T2 240.000-220.000 3.208 X Brace No No 4.500 4.500 T3 220.000-200.000 6.167 X Brace No No 9.000 9.000 T4 200.000-180.000 6.167 X Brace No No 9.000 9.000 tnx T ow.er Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page3 of 26 Project Date 08:51:59 09/04l15 B+T Group 1717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone. (918) 587-4630 FAX.- (918) 295-0265 SBA Communications Corporation B. Sevier Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End ft It Panels in in T5 180.000-160.000 6.167 XBrace No No 9.000 9.000 T6 160.000-140.000 6.167 XBrace No No 9.000 9.000 T7 140.000-120.000 6.167 XBrace No No 9.000 9.000 T8 120.000-100.000 6.167 X Brace No No 9.000 9.000 T9 100.000-80.000 6.167 X Brace No No 9.000 9.000 TIO 80.000-60.000 6.167 XBrace No No 9.000 9.000 Tll 60.000-40.000 6.167 XBrace No No 9.000 9.000 T12 40.000-20.000 6.167 X Brace No No 9.000 9.000 T13 20.000-0.000 6.167 XBrace No No 9.000 9.000 Tower Section Geometry (cont'd Tower Leg Leg Leg Diagonal Diagonal Diagonal Elevation Type Size Grade Type Size Grade n TI Solid Round 21/4 A572-50 Solid Round 1 A36 250.000-240.000 (50 ksi) (36 ksi) T2 Solid Round 21/2 A572-50 Solid Round 11/8 A36 240.000-220.000 (50 ksi) (36 ksi) T3 Solid Round 31/2 A572-50 Equal Angle L2x2xl/4 A36 220.000-200.000 (50 ksi) (36 ksi) T4 Solid Round 4 A572-50 Equal Angle L2 l/2x21/2x3/16 A36 200.000-180.000 (50 ksi) (36 ksi) T5 Solid Round 41/4 A572-SO Equal Angle L2I/2x21/2xl/4 A36 180.000-160.000 (50 ksi) (36 ksi) T6 Solid Round 41/2 A572-50 Equal Angle L21/2x21/2x5/16 A36 160.000-140.000 (50 ksi) (36 ksi) T7 Solid Round 43/4 A572-50 Equal Angle L3x3xl/4 A36 140.000-120.000 (50 ksi) (36 ksi) T8 Solid Round 4 3/4 A572-50 Equal Angle L3x3x3/8 A36 120.000-100.000 (50 ksi) (36 ksi) T9 Solid Round 5 A572-50 Equal Angle L3 1/20 1/2x5/16 A36 100.000-80.000 (50 ksi) (36 ksi) T10 Solid Round 51/4 A572-50 Equal Angle LAx4xl/4 A36 80.000-60.000 (50 ksi) (36 ksi) Tll Solid Round 51/2 A572-50 Equal Angle Lx4x3/8 A36 6.0.000-00.000_ (50 ksi) - (36 ksi) _ TI2 _ _ Solid Round _ 5314 A572-50 Equal Angle -L5k5z5/16 A36 Tower Section Geometry cont'd Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girl Bottom Girt Elevation Type Size Grade Type Size Grade ft TI Solid Round I A36 Solid Round 1 A36 250.000-240.000 (36 ksi) (36 ksi) T2 Solid Round 11/8 A36 Solid Round 11/8 A36 240 000-220.000 (36 ksi) (36 ksi) tllxTower .lob 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) Page4 of 26 Project Date 08:51:59 09/04/15 B+T Group 7717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX (918) 295-0265 SBA Communications Corporation B. Sevier Tower Section Geometry cont'd Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt (perface) A, Spacing Spacing Diagonals Horizontals ft It, in in in Tl 0.000 0.000 A36 1 1 1 0.000 0.000 250.000-240.0 (36 ksi) 00 T2 0.000 0.000 A36 l 1 1 0.000 0.000 240.000-220.0 (36 ksi) 00 T3 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 220.000-200.0 (36 ksi) 00 T4 0.000 0.000 A36 1.05 l 1.05 0.000 0.000 200.000-180.0 (36 ksi) 00 T5 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 180.000-160.0 (36 ksi) 00 T6 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 160.000-140.0 (36 ksi) 00 T7 0.000 0.000 A36 1.05 l 1.05 0.000 0.000 140.000-120.0 (36 ksi) 00 T8 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 120.000-100.0 (36 ksi) 00 T9 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 100.000-80.00 (36 ksi) 0 T10 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 80.000-60.000 (36 ksi) T11 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 60,000-40.000 (36 ksi) T12 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 40.000-20.000 (36 ksi) T13 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 20.000-0.000 (36 ksi) -- ----- Tower-Section-Geomet , c)n - KFactorst Tower Cale Cale Legs X K Single Girts Horiz. Sec. Inner Elevation K K Brace Brace Diags Horiz. Brace Single Solid Diags Diags Angles Rounds X X K X X X X y y y y Y y y T1 No Yes 250.000-240.0 00 T2 No Yes 240.000-220.0 00 T3 Yes Yes 220.000-200.0 A �+ �iix over Job Page 100926.001.01 - TC SR-70, FL (Site# FL17O5O-A ) 5 of 26 Project Date B+T Group 1717 SBoulder Ave, Suite300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Tower Cale Elevation K Single Angles T4 Yes 200.000-180.0 00 T5 Yes 180.000-160.0 00 T6 Yes 160.000-140.0 00 T7 Yes 140.000-120.0 00 T8 Yes 120.000-100.0 00 T9 Yes 100.000-80.00 0 T10 Yes 80.000-60.000 Tll Yes 60.000-40.000 T12 Yes 40.000-20.000 T13 Yes 20.000-0.000 'Note: Kfactors are apt the overall length Cale Legs X K Single Girts Hertz. See. timer K Brace Brace Diags Hertz: Brace Solid Diags Diags Rounds X X X X X X X y Y Y Y Y Y y Yes 1 1 1 1 l l I 1 1 1 1 1 l l 1 Yes I 1 1 1 l 1 I 1 1 1 1 1 1 1 Yes I l ] 1 I 1 1 1 1 1 l l 1 1 1 Yes I l l I 1 l l 1 1 I I l l l 1 Yes l 1 I 1 l 1 1 1 1 1 1 1 I t 1 Yes 1 1 1 1 I 1 I I 1 I l 1 1 1 1 Yes 1 1 1 1 1 1 1 1 I 1 I 1 1 1 1 Yes I 1 1 1 1 l l 1 1 I 1 l l l 1 Yes 1 I 1 1 l l l 1 1 1 1 1 Yes 1 1 1 1 1 1 1 1 i 1 l I 1 1 1 to member segment [engtns. K-Daces inner supporting 'Tower Section Geometry ( cont'd applied to Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation ft. _ _ Net Width U Net Width U Net Width U Net U Net U Net U Net U - - -- -- -- educt - -- -Deduct-_--Deduct - Width- --M,*h --Width - -Fh-in - -- - - _ . ... - -Deduct- _ - -D in in in in - TI 0.000 1 0.000 l 0.000 I 0.000 1 0.000 0.75 0.000 --- _- 1 --- 0.000 - 0.75 250.000-240.0 00 T2 0.000 1 0.000 1 0.000 1 0.000 1 0.000 0.75 0.000 1 0.000 0.75 240.000-220.0 00 T3 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 220.000-200.0 00 T4 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 200.000-180.0 00 T5 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 180.000-160.0 00 tnxTo11 er Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) Page6 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX.- (918) 295-0265 SBA Communications Corporation B. Sevier Tower Ele ation ft Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Net 11 <dth U Net Width U Net Width U Net U Net U Net U Net U Deduct Deduct Deduct Width Width Wdth Width in in in Deduct Deduct Deduct Deduct in in in in T6 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 160.000-140.0 00 T7 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 140.000-120.0 00 T8 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 120.000-100.0 00 T9 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 100.000-80.00 0 T10 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 80.000-60.000 Tll 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 60.000-40.000 T12 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 40.000-20.000 T13 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 20.000-0.000 Tower Section Geometry cont'd Tower Leg Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Elevation Connection ft Type Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. in in in in in in in T1 Flange 1.125 6 0.000 0 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 250.000-240.0 A325N A325N A325N A325N A325N A325N A325N 00 T2 Flange 1.125 6 0.000 0 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 240.000-220.0 - A325N A325N A325N A325N A325N A325N A325N- 00 T3 Flange 1.125 _. 6 0.875 1_ 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 - 220.000-200.0. - _.A325N _A325N A325N A325N A325N A325N A_325N 00 - _. _ - - T4 -- - --Flange - 1.125 - 8- 0.975- 1 -0.000 0- - 0.000 0 -0.625 0 -0.000 0 0.625 0 200.000-180.0 A325N A325N A325N A325N A325N A325N A325N 00 T5 Flange 1.125 8 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 180.000-160.0 A325N A325N A325N A325N A325N A325N A325N 00 T6 Flange 1.125 8 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 160.000-140.0 A325N A325N A325N A325N A325N A325N A325N 00 T7 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 140.000-120.0 A325N A325N A325N A325N A325N A325N A325N 00 T8 Flange 1.125 12 0.975 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 120.000-100.0 A325N A325N A325N A325N A325N A325N A325N 00 t Tower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 7 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX. (918) 295-0265 SBA Communications Corporation B. Sevier Tower Elevation jt Leg Connection Type Leg Bolt Size No. Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. in in in in in in in T9 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 100.000-80.00 A325N A325N A325N A325N A325N A325N A325N 0 TIO Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 80.000-60.000 A325N A325N A325N A325N A325N A325N A325N Tit Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 60.000-40.000 A325N A325N A325N A325N A325N A325N A325N T12 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 40.000-20.000 A325N A325N A325N A325N A325N A325N A325N T13 Flange 1.375 0 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 20.000-0.000 A449 A325N A325N A325N A325N A325N A325N Feed Line/Linear Appurtenances- Entered As -Round Or Flat Description Face Allow Component Placement Face Lateral # # Clear Width or Perimeter Weight or Shield Type Offset Offset Per Spacing Diameter Leg ft in (Frac FW) Row in in in klf LDF7-50A(I- A No At (CaAa) 248.000 - 0.000 0.000 -0.42 6 6 0.850 1.980 0.001 5/8) 0.750 (E) LDF6-50A(1- A No At (CaAa) 248.000 - 0.000 0.000 -0.38 3 3 0.850 1.550 0.001 1/4") 0.750 Fe dline A No Af (CaAa) 248.000 - 0.000 0.000 -0.4 1 1 3.000 3.000 0.008 Ladder (All (E) a<da• 9207(5/8") C No Ar (CaAa) 125.500 - 0.000 0.000 0.48 2 2 0.350 0.330 0.001 (E-lighting Cable) 9207(5/8") C No Ar (CaAa) 250.000 - 125.500 0.000 0.48 1 1 0.350 0.330 0.001 (E-lighting Cable) aidaa ,Safety Line C -No At (CaAa) - 250.000 - 0.000 _ 0.000 -__ 0.5 ._ 1 _ _ 1 0.375 _ 0.375 0.000 _ 3/8 Feed Line/Linear Appurtenances Section Areas Tower Tower Face As AF C�AA CA, Weight Section Elevation In Face Out Face R ft, f? fit f? K TI 250.000-240.000 A 0.000 0.000 17.224 0.000 0.122 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 0.705 0.000 0.008 T2 240.000-220.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T3 220.000-200.000 A 0.000 0.000 43.060 0.000 0.306 taxTower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) Page8 of 26 B+T Group 1717 S Boulder Ave, Suite 300 Project Date 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX: (918) 295-0265 SBA Communications Corporation B. Sevier Tower Tower Face AR Ar CA, C, 4h Weight Section Elevation In Face Out Face ft I f fr ft, K B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T4 200.000-180.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T5 180.000-160.000 A 0,000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T6 160.000-140.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T7 140.000-120.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.591 0.000 0.020 T8 120.000-100.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T9 100.000-80.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T10 80.000-60.000 A 0.000 0.000 43.060 0.000 0.306 B 0,000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 Tit 60.000-40.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T12 40.000-20.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T13 20.000-0.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 Feed Line Center of Pressure Section Elevation CPx CPz CPx Cps Ice Ice ft in in in in - -T1 _- --250.000-240.000- - -3.854' -- - - 1.633- - 4.432 - -- 1i859- T2 240.000-220.000 -4.032 1.703 -4.642 1.942 O. _ _180.000-160.000 _ . .Yr39 - ,6.852. _ 2A 3.043_ _ -7.878 _ _ 3.476 - T5. T6 160.000-140.000 -7.947 3.556 -9.134 4.062 T7 140.000-120.000 -8.519 3.838 -9.786 4.382 T8 120.000-100.000 -9.494 4.309 -10.889 4.912 T9 100.000-80.000 -9.698 4.414 -11.122 5.032 T10 80.000-60.000 -9.763 4.453 -11.195 5.077 Tit 60.00040.000 -10.264 4.690 -11.769 5.348 T12 40.000-20.000 -9.610 4.398 -11.019 5.016 T13 20.000-0.000 -10.009 4.587 -11.476 5.231 0 WxTonler Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 9 of 26 Project Date B+T Group 1717 SBoulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Shielding Factor Ka Tower Feed Line Description Feed Line K. K. Section Record No. Se merit Elev. No lee Ice TI 2 LDF7-50A(1-5/8) 240.00- 0.6000 0.6000 248.00 T1 3 LDF6-50A(1-1/4") 240.00- 0.6000 0.6000 248.00 T1 4 Feedline Ladder (At) 240.00- 0.6000 0.6000 248.00 T1 7 9207(5/8") 240.00- 0.6000 0.6000 250.00 T1 9 Safety Line 318 240.00- 0.6000 0.6000 250.00 T2 2 LDF7-50A(l-5/8) 220.00- 0.6000 0.6000 240.00 T2 3 LDF6-50A(l-1/4") 220.00- 0.6000 0.6000 240.00 T2 4 Feedline Ladder (At) 220.00- 0.6000 0.6000 240.00 72 7 9207(5/8") 220.00- 0.6000 0.6000 240.00 T2 9 Safety Line 3/8 220.00- 0.6000 0.6000 240.00 T3 2 LDF7-50A(1-5/8) 200.00- 0.6000 0.6000 220.00 T3 3 LDF6-50A(l-1/4") 200.00- 0.6000 0.6000 220.00 T3 4 Feedline Ladder (At) 200.00- 0.6000 0.6000 220.00 T3 7 9207(5/8") 200.00 - 0.6000 0.6000 220.00 T3 9 Safety Line 3/8 200.00- 0.6000 0.6000 220.00 T4 2 LDF7-50A(1-5/8) 180.00- 0.6000 0.6000 200.00 T4 3 LDF6-50A(1-1/4") 180.00- 0.6000 0.6000 200.00 T4 4 Feedline Ladder (At) 180.00- 0.6000 0.6000 200.00 T4 7 9207(5/8") 180.00- 0.6000 0.6000 200.00 T4 9 Safety Line 3/8 180.00- 0.6000 0.6000 200.00 _ ___ T5 2 LDF7-50A(1-5/8) 160.00- 0.6000 0.6000 - 80.00 - `_- - - - - - - - _ _ _ _ _ _ 180.00 T5 4 Feedline Ladder (Al) 160.00- 0.6000 0.6000 180.00 T5 7 9207(5/8") 160.00- 0.6000 0.6000 180.00 T5 9 Safety Line 3/8 160.00- 0.6000 0.6000 180.00 T6 2 LDF7-50A(1-5/8) 140.00- 0.6000 0.6000 160.00 T6 3 LDF6-50A(I-1/4") 140.00- 0.6000 0.6000 160.00 T6 4 Feedline Ladder (At) 140.00- 0.6000 0.6000 160.00 T6 7 9207(5/8") 140.00- 0.6000 0.6000 160.00 T6 9 Safety Line 3/8 140.00- 0.6000 0.6000 WxTUWer Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 10 of 26 Project Date B+T Group 1717SBoulderAve, Suite300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Tower Feed Line Description Feed Line K" P Section Record No. Se ment Elev. No lee Ice 460.00 T7 2 LDF7-50A(1-5/8) 120.00- 0.6000 0.6000 140.00 T7 3 LDF6-50A(l-1/4") I20.00- 0.6000 0.6000 140.00 T7 4 Feedline Ladder (Af) 120.00 - 0.6000 0.6000 140.00 T7 6 9207(5/8") 120.00- 0.6000 0.6000 125.50 T7 7 9207(5/8") 125.50 - 0.6000 0.6000 140.00 T7 9 Safety Line 3/8 120.00- 0.6000 0.6000 140.00 T8 2 LDF7-50A(1-5/8) 100.00- 0.6000 0.6000 120.00 T8 3 LDF6-50A(I-1/4") 100.00- 0.6000 0.6000 120.00 T8 4 Feedline Ladder (At) 100.00- 0.6000 0.6000 120.00 T8 6 9207(5/8") 100.00- 0.6000 0.6000 120.00 T8 9 Safety Line 3/8 100.00- 0.6000 0.6000 120.00 T9 2 LDF7-50A(l-5/8) 80.00-100.00 0.6000 0.6000 T9 3 LDF6-50A(l-1/4") 80.00-100.00 0.6000 0.6000 T9 4 Feedline Ladder (Af) 80.00 - 100.00 0.6000 0.6000 T9 6 9207(5/8") 80.00- 100.00 0.6000 0.6000 T9 9 Safety Line 3/8 80.00 - 100.00 0.6000 0.6000 T10 2 LDF7-50A(I-5/8) 60.00-80.00 0.6000 0.6000 T10 3 LDF6-50A(1-1/4") 60.00-80.00 0.6000 0.6000 T10 4 Feedline Ladder (Ai) 60.00 - 80.00 0.6000 0.6000 T10 6 9207(5/8") 60.00-80.00 0.6000 0.6000 T10 9 Safety Line 3/8 60.00 - 80.00 0.6000 0.6000 Tll 2 LDF7-50A(1-5/8) 40,00-60.00 0.6000 0.6000 Tll 3 LDF6-50A(1-1/4") 40.00-60.00 0.6000 0.6000 T11 4 Feedline Ladder (At) 40.00 - 60.00 0.6000 0.6000 T11 6 9207(5/8") 40.00-60.00 0.6000 0.6000 TI1 9 Safety Line 318 40.00 - 60.00 0.6000 0.6000 T12 2 LDF7-50A(1-5/8) 20.00-40.00 0.6000 0.6000 T12 3 LDF6-SOA(1-1/4") 20.00-40.00 0.6000 0.6000 T12 4 Feedline Ladder (Af) 20.00 - 40.00 0.6000 0.6000 T12 6 9207(5/8") 20.00-40.00 0.6000 0.6000 -- - T12 - - - 9 -- -- -Safety Linea/8 20.00-40.00 - -0.6000 ---0:6000 T13 2 LDF7-50A(l-5/8) 0.00-20.00 0.6000 0.6000 -T13 -- 3 - - L-DF6--50A(l-V ") -mine-lad 0.00-2"0 .6000 -"000 der -(rt$ - : - - . 0 _T13 6 9207(5/8') 0.00-20.00 0.6000 0.6000 T131 91 Safety Line 3/81 0.00 -2 0 0.6000 0.6000 l MxTower Job Page f 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 11 of 26 B+T Group Project Date 1717SBoulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX' (918) 295-0265 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CrAA C.AA Weight or Type llorz Adjustment Front Side Leg Lateral Vert ft 0 fi fr ft, K Lightning Rod 5/8" x4' on 6' A From Leg 0.000 0.000 255.000 No Ice 2.339 2.339 0.085 Pole 0.000 (E) 0.000 Strobe C From Leg 0.000 0.000 251.000 No Ice 5.250 3.500 0.020 (E) 0.000 0.000 Side Lighting A From Leg 0.500 0.000 125.500 No Ice 0.133 0.133 0.005 (E) 0.000 0.000 Side Lighting B From Leg 0.500 0.000 125.500 No Ice 0,133 0.133 0.005 (E) 0.000 0.000 Side Lighting C From Leg 0.500 0.000 125.500 No Ice 0.133 0.133 0.005 (E) 0.000 0.000 sxd<x (2) CMA-BDHH/6520/E0-8 A From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 (2) CMA-BDHH/6520/EO-8 B From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 (2) CMA-BDFIH/6520/EO-8 C From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 FXFB A From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 FXFB B From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 FXFB C From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 _ - -- - - -FRIG- - - - A From Leg 4.000 0.000- - '248.000 - -No Ice- 2.'197 - -1.096 - -0.048 - ---- -- =-- (E) 0.000 000 -- - - - - Ri - - - - _ - ... -- : 00- B:EiO^o - - -34&000�N le;.:-2. 97 1._ (E)- 0.000 0.000 FRIG C From Leg 4.000 0.000 248.000 No Ice 2.797 1.096 0.048 (E) 0.000 0.000 FRIE A From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 FRIE B From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 FRIE C From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 ASU9338TYPOI A From Leg 4.000 0.000 248.000 No Ice 3.737 1.155 0.019 (E) 0.000 Wx ower j Job Page F 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 12 of 26 Project Date B+T Group 1717 S BoulderAve, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Description Face Offset Offsets: Azimuth Placement CAAA C,v1,, Weight or Type Hors Adjustment Front Side Leg Lateral Vert f R f? ft, K R _ ft 0.000 ASU9338TYPOI B From Leg 4.000 0.000 248.000 No Ice 3.737 1.155 0.019 (E) 0.000 0.000 ASU9338TYPOI C From Leg 4.000 0.000 248.000 No Ice 3.737 1.155 0.019 (E) 0.000 0.000 DBXNH-6565E-A2M w/ A From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0.072 Mount Pipe 0.000 (P) 0.000 DBXNH-6565B-A2M w/ B From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0.072 Mount Pipe 0.000 (P) 0.000 DBXNH-6565B-A2M w/ C From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0.072 Mount Pipe 0.000 (P) 0.000 Sector Mount [SM 1303-3] C None 0.000 248.000 No Ice 30.200 30.200 1.104 (F) --it** Load Combinations Comb. Description No. 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg -No Ice 5 0.9 Dead+1.6 Wind 30 deg -No Ice 6 1.2 Dea1+1.6 Wind 60 deg - No Ice 7 0.9 Dead+1.6 Wind 60 deg -No Ice 8 1.2 Dead+1.6 Wind 90 deg -No Ice• - - - - -- 9 0.9 Dead+1.6 Wind 90 dee - No Ice 0.9-Dead±t 6MPd420-deg-No-ke_ 12 1.2 Dead+1.6 Wiad 150 deg - No Ice 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg - No Ice 15 0.9 Dead+1.6 Wind 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wind 210 deg - No Ice 18 1.2 Dead+1.6 Wind 240 deg - No Ice 19 0.9 Dead+1.6 Wind 240 deg - No Ice 20 1.2 Dead+1.6 Wind 270 deg - No Ice 21 0.9 Dead+1.6 Wind 270 deg -No Ice 22 1.2 Dead+1.6 Wind 300 deg -No Ice 23 0.9 Dead+1.6 Wind 300 deg -No Ice 24 1.2 Dead+1.6 Wind 330 deg - No Ice 25 0.9 Dead+1.6 Wind 330 deg -No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg -Service l WxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 13 of 26 Project Date B+T Group 1717 S BoulderAve, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. $eVlef FAX (918) 295-0265 Comb. Description No. 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg - Service 31 Dead+Wind 150 deg - Service 32 Dead+Wind 180 deg - Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service Maximum, Member Forces Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip ft kip-R TI 250-240 Leg Max Tension 7 19.049 0.821 -0.491 Max. Compression 18 -21.391 0.263 -0.156 Max. Mx 20 -1.027 -1.511 0.002 Max. My 2 -0.323 0.023 -1.513 Max. Vy 20 -3.206 0.276 -0.053 Max. Vx 2 -3.361 -0.011 0.304 Diagonal Max Tension 4 4.213 0.000 0.000 Max. Compression 16 -4.228 0.000 0.000 Max. Mx 18 0.543 -0.004 -0.000 Max. My 16 -3.809 -0.002 0.002 Max. Vy 18 -0.005 -0.004 -0.000 Max. Vx 16 -0.001 -0.002 0.002 Top Girt Max Tension 18 0.069 0.000 0.000 Max. Compression 7 -0.065 0.000 0.000 Max. Mx 6 -0.065 0.006 0.000 Max. My 24 0.004 0.000 -0.000 Max. Vy 6 -0.006 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 Bottom Gin Max Tension 6 1.202 0.000 0.000 Max. Compression 19 -1.196 0.000 0.000 Max. Mx 6 1.202 0.006 0.000 Max. My 24 0.058 0.000 -0.000 Max. Vy 6 -0.006 0.000 0.000 - - - -Max..-Vx 24 0.000 0.000 0.000 - ----- T2 240 - 220 Leg Max Tension 7 78.362 0.984 -0.590 *"ax.-Compression-N -82:625 1:083 - 0.63. - - - *"az..R4,: _ _ _ _ _20. _ _ °3A93_ W78-_ _- Max. My 2 -26.069 -0.061 1.563 _ Max. Vy 10 5.849 -1.085 -0.591 Max. Vx 2 -6.627 -0.032 1.238 Diagonal Max Tension 4 5.710 0.000 0.000 Max. Compression 16 -5.769 0.000 0.000 Max. Mx is 4.541 -0.012 -0.000 Max. My 24 -5.129 0.004 -0.004 Max. Vy 18 0.009 -0.012 -0.000 Max. Vx 24 0.002 0.004 -0.004 Top Girt Max Tension 18 1.523 0.000 0.000 Max. Compression 6 -1.521 0.000 0.000 Max. Mx 6 -1.521 0.008 0.000 Max. My 24 -0.038 0.000 -0.000 Max. Vy 6 -0.008 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 Bottom Girt Max Tension 11 0.083 0.000 0.000 tnxTower Job Page14 100926.001.01 - TC SR-70, FL (Site# FL17050-A) of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918)195-0265 Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip ft kip ft Max. Mx 6 0.055 0.008 0.000 Max. My 24 0.029 0.000 -0.000 Max. Vy 6 -0.008 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 T3 220 - 200 Leg Max Tension 7 105.276 1.668 -0.030 Max. Compression 18 -112.181 0.709 -0.011 Max. Mx 18 -82.909 2.813 -0.059 Max. My 12 -2.680 0.016 -1.326 Max. Vy 10 -3.617 0.712 -0.054 Max. Vx 12 1.854 0.016 -1.326 Diagonal Max Tension 15 4.235 0.000 0.000 Max. Compression 2 -4.569 0.000 0.000 Max. Mx 16 1.658 0.038 -0.006 Max. My 4 -4.260 -0.016 0.022 Max. Vy 16 -0.015 0.038 -0.006 Max. Vx 4 -0.007 0.000 0.000 T4 200-180 Leg Max Tension 7 129.430 2.356 -0.034 Max. Compression 18 -140.218 0.635 -0.008 Max. Mx 10 -110.725 3.419 -0.269 Max. My 12 -4.026 -0.017 -1.649 Max. Vy 10 -4.564 0.636 -0.047 Max. Vx 12 1.974 -0.001 -0.432 Diagonal Max Tension 4 4.420 0.000 0.000 Max. Compression 4 -4.391 0.000 0.000 Max. Mx 20 1.811 0.031 0.001 Max. My 2 4.163 -0.013 0.009 Max. Vy 20 0.014 0.031 0.001 Max. Vx 2 -0.002 0.000 0.000 T5 I80 - 160 Leg Max Tension 7 153.275 3.068 -0.037 Max. Compression 18 -168.868 0.708 -0.007 Max. Mx 10 -138.571 4.058 -0.319 Max. My 12 -5.529 -0.016 -1.924 Max. Vy 10 -5.874 0.710 -0.050 Max. Vx 12 2.450 -0.007 -0.500 Diagonal Max Tension 4 5.167 0.000 0.000 Max. Compression 4 -5.121 0.000 0.000 Max. Mx 20 2.118 0.039 0.002 Max. My 2 -4.933 -0.005 0.011 Max. Vy 20 0.019 0.039 0.002 Max. Vx 2 -0.002 0.000 0.000 - T6 160-140 Leg Max Tension '7 177.393 3.883- -0.042 - Max. Compression 18 -198.663 0.733 -0.005 Max. Vy 10 -7.257 0.734 -0.040 Max. Vx 12 2.980 -0.014 -0.485 Diagonal Max Tension 4 6.095 0.000 0.000 Max. Compression 4 -6.003 0.000 0.000 Max. Mx 20 2.470 0.049 0.004 Max. My 2 -5.807 0.008 0.012 Max. Vy 20 0,026 0.049 0.004 MM Vx 2 -0.002 0.000 0.000 T7 140 - 120 Leg Max Tension 23 202.442 5.091 -0.327 Max. Compression 18 -230.116 0.485 -0.005 Max. Mx 10 -227.815 -6.262 0.426 MU. My 12 -9.365 -0.006 -2.733 Max. Vy 10 -8.993 0.485 -0.040 Max. Vx 12 3.644 0.012 -0.421 Diagonal Max Tension 4 7.270 0.000 0.000 Max. Compression 4 -7.172 0.000 0.000 WxTower l Job Page 4 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 15 of 26 Project Date B+T Group 1717SBoulderAve, Suite300 _ 08:51:5909/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX- (918) 295-0265 Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip ft kip ft Max. Mx 20 2.916 0.062 0.005 Max. My 2 -6.966 0.013 0.016 Max. Vy 20 0.029 0.062 0.005 Max. Vx 2 -0.003 0.000 0.000 T8 120 - 100 Leg Max Tension 23 228.401 5.724 -0.371 Max. Compression 18 -263.427 0.918 -0.006 Max. Mx 10 -227.922 7.235 -0.510 Max. My 12 -11.637 0.041 -3.169 Max. Vy 10 -10.863 0.920 -0.049 Max. Vx 12 4.302 -0.015 -0.598 Diagonal Max Tension 4 8.504 0.000 0.000 Max. Compression 4 -8.340 0.000 0.000 Max. Mx 20 3.361 0.102 0.009 Max. My 2 -8.129 0,036 0.021 Max. Vy 20 0.047 0.102 0.009 Max. Vx 2 -0.004 0.000 0.000 T9 100 - 80 Leg Max Tension 23 255.733 6.931 -0.434 Max. Compression 18 -298.996 0.996 -0.005 Max. Mx 10 -261.042 9.127 -0.593 Max. My 12 -14.268 0.056 -3.839 Max. Vy 10 -12.985 0.997 -0.039 Max. Vx 12 5.066 -0.018 -0.580 Diagonal Max Tension 4 10.000 0.000 0.000 Max. Compression 4 -9.765 0.000 0.000 Max. Mx 20 3.977 0.123 0.011 Max. My 2 -9.560 0.047 0.026 Max. Vy 20 0.052 0.123 0.011 Max. Vx 2 -0.004 0.000 0.000 TI O 80 - 60 Leg Max Tension 23 284.328 7.801 -0.430 Max. Compression 18 -336.669 1.619 -0.015 Max. Mx 10 -296.433 10.678 -0.656 Max. My 12 -17.131 0.040 4.395 Max. Vy 10 -15.288 1.624 -0.120 Max. Vx 12 5.897 0.032 -1.041 Diagonal Max Tension 4 11.406 0.000 0.000 Max. Compression 4 -11.248 0.000 0.000 Max. Mx 20 4.557 0.136 0.013 Max. My 2 -11.060 0.059 0.029 Max. Vy 20 0.053 0.136 0.013 Max. Vx 2 -0.004 0.000 0.000 Tit 60 - 40 Leg. Max Tension 23 313.909 9.263 -0.521 - - - - - -"- -" " - - -- -- Max. -Compression --- 18 --377.161- "'1.333 -0.007 Max. Mx 10 -333.921 13.086 -0.806 ---=--In- K7Yfd6 GS3t»t.067- _ Max. Vx_ _ 12 6.670 -0.008 -0.818. Diagonal Max Tension 4 13.182 0.000 0.000 Mu. Compression 4 -12.943 0.000 0.000 Max. Mx 20 5.160 0.219 0.021 Max. My 2 -12.751 0.123 0.039 Max. Vy 20 0.085 0.219 0.021 Max. Vx 2 -0.005 0.000 0.000 T12 40-20 Leg Max Tension 23 344.639 I1.483 -0.612 Max. Compression 18 -419.997 0.361 0.001 Max. Mx 10 416.724 -14.862 0.808 Max. My 12 -24.006 0.197 -5.837 Max. Vy 10 -20.273 0.359 0.003 Max. Vx 12 7.593 -0.017 -0.385 Diagonal Max Tension 2 15.232 0.000 0.000 Max. Compression 4 -14.796 0.000 0.000 Max. Mx 20 5.887 0.283 0.026 WxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 16 of 26 B+T Group Project Date 1717SBoulderAve, Suite-300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone. (918) 587-4630 SBA Communications Corporation B. Sevier FAX.' (918) 295-0265 Section Elevation No. jt Component Type. Condition Gov. Load Comb. Axial K Major Axis Moment kiDft Minor Axis Moment kip-ft Max. My 2 -14.584 0.139 0.053 Max. Vy 20 0.099 0.283 0.026 Max. Vx 2 -0.007 0.000 0.000 T13 20 - 0 Leg Max Tension 23 376.311 13.157 -0.644 Max. Compression 18 -464.430 0.000 0.000 Max. Mx 10 -460.971 -17.283 0.860 Max. My 12 -28.237 0.214 -6.096 Max. Vy 10 -23.017 0.000 0.000 Max. Vx 12 8.108 0.000 -0.000 Diagonal Max Tension 2 16.847 0.000 0.000 Max. Compression 4 -16.429 0.000 0.000 Max. Mx 8 6.752 0.310 -0.030 Max. My 2 -16.083 0.158 0.055 Max. Vy 8 0.105 0.310 -0.030 Max. Vx 2 -0.007 0.000 0.000 .Maximum Reactions Location Condition Gov. Vertical Horizontal, X Horontal, Z Load K K K Leg C Max. Vert 18 462.653 40.309 -23.413 Max. H, 18 462.653 40.309 -23.413 Max. H, 5 -327.300 -28.056 21.186 Min. Vert 7 -373.724 -34.092 19.814 Min. H. 7 -373.724 -34.092 19.814 Min. H. 18 462.653 40.309 -23.413 Leg B Max. Vert 10 459.274 40.799 -22.385 Max. H, 23 -374.594 34.598 18.884 Max. H, 25 -328.027 28.898 19.565 Min. Vert 23 -374.594 34.598 18.884 Min. 11, 10 459.274 40.799 -22.385 Min. H. 10 459.274 -40.799 -22.385 Leg Max. Vert 2 459.554 -1.077 46.529 Max. H, 19 -192.180 7.029 -21.081 Max. H. 2 459.554 -1.077 46.529 Min. Vert 15 -374.385 0.994 -39.401 - - - - Min; H. - 9 -23374- -6.408' - - h704' - - - - - - - -- - Min. H� 15 -374.385 0.994 -39AOI Tower_Mast .Reaction Suininary Load Combination Vertical K Shear, K Shear, K Overturning Moment, M. kip ft Overturning Moment, M, kip-/t Torque kip ft Dead Only 77.314 0.000 0.000 11.209 25.217 0.000 1.2 Dead+1.6 Wind 0 deg - No 92.776 0.047 -78.989 -9280.083 18.550 48.181 Ice 0.9 Dead+1.6 Wind 0 deg - No 69.582 0.047 -78.989 -9275.082 10.958 48.150 Ice 1.2 Dead+1.6 Wind 30 deg - No 92.776 36.443 -63.026 -7594.805 4375.955 -26.087 Ice 0.9 Dead+1.6 Wind 30 deg -No 69.582 36.443 -63.026 -7591.243 -4379.543 -26.068 MxTower ( Job Page Q 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 17 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Load Vertical Shear, Shear. Overturning Overturning Torque Combination Moment, M, Moment, M_ K K K kin-1t kin-(t kin-8 1.2 Dead+1.6 Wind 60 deg - No 92.776 61.258 -35.368 4299.616 -7440.137 4.777 Ice 0.9 Dead+1.6 Wind 60 deg - No 69.582 61.258 -35.368 -4299.044 -7440.900 4.773 Ice 1.2 Dead+1.6 Wind 90 deg - No 92.776 72.804 -0.047 1.650 -8761.772 20.693 Ice 0.9 Dead+1.6 Wind 90 deg -No 69.582 72.804 -0.047 -1.720 -8761.359 20.681 Ice 1.2 Dead+1.6 Wind 120 deg - 92.776 68.430 39.454 4650.052 -8024.013 45.401 No Ice 0.9 Dead+1.6 Wind 120 deg - 69.582 68.430 39.454 4642.493 -8024.356 45.374 No Ice 1.2 Dead+1.6 Wind 150 deg - 92.776 36.361 62.979 7609.911 -4355.352 50.568 No Ice 0.9 Dead+1.6 Wind 150 deg - 69.582 36.361 62.979 7599.621 4358.962 50.534 No Ice 1.2 Dead+1.6 Wind I80 deg - 92.776 -0.047 70.654 8619.093 42.309 41.841 No Ice 0.9 Dead+1.6 Wind I80 deg - 69.582 -0.047 70.654 8607.833 34.692 41.813 No Ice 1.2 Dead+1.6 Wind 210 deg - 92.776 -36.443 63.026 7621.725 4436.756 26.088 No Ice 0.9 Dead+1.6 Wind 210 deg- 69.582 -36.443 63.026 7611.408 4425.128 26.069 No Ice 1.2 Dead+1.6 Wind 240 deg - 92.776 -68.477 39.535 4670.556 8096.644 5.452 No Ice 0.9 Dead+1.6 Wind 240 deg - 69.582 -68.477 39,535 4662.976 8081.765 5.448 No Ice 1.2 Dead+1.6 Wind 270 deg - 92.776 -72.804 0.047 25.419 8822.474 -20.694 No Ice 0.9 Dead+1.6 Wind 270 deg- 69.582 -72.804 0.047 22.025 8806.851 -20.682 No Ice 1.2 Dead+1.6 Wind 300 deg- 92.776 -61.211 -35.286 -4278.964 7488.993 -39.736 No Ice 0.9 Dead+1.6 Wind 300 deg - 69.582 -61.211 -35.286 -4278.412 7474.559 -39.712 No Ice 1.2 Dead+1.6 Wind 330 deg - 92.776 -36.361 -62.979 -7582.857 4416.187 -50.568 No Ice 0.9 Dead+1.6 Wind 330 deg- 69.582 -36.361 -62.979 -7579.321 4404.596 -50.534 No Ice -- Dead+Wind'0 deg -Service 77.314 0.008 -12.983 -1515.408 23.330 -7.914 - Dead+Wind 30 deg - Service 77.314 5.990 -10.359 -1238.560 -698.540 -4.291 Dead+Wind-60 deg-Semite--------7"14 - -- 10:069 --5:813 -697268 -12017882 -0..785 Dead+Win 90-deb-Service-�fi3t4 1-1:966- 0.00 -- _ - -1418:983-- --3.406 Dead+Wind 120 deg- Service 77.314 11.248 6.485 772.868 -1297.806 _ 7.457 Dead+Wind 150 deg -Service 77.314 5.976 10.352 1259.079 -695.158 8.305 Dead+Wind 180 deg - Service 77.314 -0.008 11.613 1424.859 27.236 6.872 Dead+Wind 210 deg - Service 77.314 -5.990 10.359 1261.028 749.105 4.291 Dead+Wind 240 deg -Service 77.314 -11.255 6.498 776.247 1350.319 0.896 Dead+Wind 270 deg -Service 77.314 -11.966 0.008 13.189 1469.545 -3.405 Dead+Wind 300 deg - Service 77.314 -10.061 -5.800 -693.883 1250.492 -6.527 Dead+Wind 330 deg -Service 77.314 -5.976 -10.352 -1236.605 745.724 -8.305 l WxTower Job Page [ 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 18 of 26 Project Date B+T Group 1717 S Boulder Ave, Suile 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Solution Sumthiry Load Comb. PX K Sum of Applied Forces PY K PZ K PX K Sum of Reactions PY K PZ K %Error 1 0.000 -77.314 0.000 0.000 77.314 0.000 0.000% 2 0.047 -92.776 -78.989 -0.047 92.776 78.989 0.000% 3 0.047 -69.582 -78.989 -0.047 69.582 78.989 0.000% 4 36.443 -92.776 -63.026 -36.443 92.776 63.026 0.000% 5 36.443 -69.382 -63.026 -36.443 69.582 63.026 0.000% 6 61.259 -92.776 -35.368 -61.258 92.776 35.368 0.000% 7 61.259 -69.582 -35.368 -61.258 69.582 35.368 0.000% 8 72.804 -92.776 -0.047 -72.804 92.776 0.047 0.000% 9 72.804 -69.582 -0.047 -72.804 69.582 0.047 0.000% 10 68.430 -92.776 39.454 -68.430 92.776 -39.454 0.000% 11 68.430 -69.582 39.454 -68.430 69.582 -39.454 0.000% 12 36.361 -92.776 62.979 -36.361 92.776 -62.979 0.000% 13 36.361 -69.582 62.979 -36.361 69.582 -62.979 0.000% 14 -0.047 -92.776 70.654 0.047 92.776 -70.654 0.000% 15 -0.047 -69.582 70.654 0.047 69.582 -70.654 0.000% 16 -36.443 -92.776 63.026 36.443 92.776 -63.026 0.000% 17 -36.443 -69.582 63.026 36.443 69.582 -63.026 0.000% 18 -68.477 -92.776 39.535 68.477 92.776 -39.535 0.000% 19 -68.477 -69.582 39.535 68.477 69.582 -39.535 0.000% 20 -72.804 -92.776 0.047 72.804 92.776 -0.047 0.000% 21 -72.804 -69.582 0.047 72.804 69.582 -0.047 0.000% 22 -61.211 -92.776 -35.286 6L211 92.776 35286 0.000% 23 -61.211 -69.582 -35.286 61.211 69.582 35.286 0.000% 24 -36.361 -92.776 -62.979 36.361 92.776 62.979 0.000% 25 -36.361 -69.582 -62.979 36361 69.582 62.979 0.000% 26 0.008 -77.314 -12.983 -0.008 77.314 12.983 0.000% 27 5.990 -77.314 -10.359 -5.990 77.314 10.359 0.000% 28 10.069 -77.314 -5.813 -10.069 77.314 5.813 0.000% 29 11.966 -77.314 -0.008 -11.966 77.314 0.008 0.000% 30 11.248 -77.314 6.485 -11.248 77.314 -6.485 0.000% 31 5.976 -77.314 10.352 -5.976 77.314 -10.352 0.000% 32 -0.008 -77.314 11.613 0.008 77.314 -11.613 0.000% 33 -5.990 -77.314 10.359 5.990 77.314 -10.359 0.000% 34 -11.255 -77.314 6.498 11.255 77.314 -6.498 0.000% 35 -11.966 -77.314 0.008 11.966 77.314 -0.008 0.000% 36 -10.061 -77.314 -5.800 10.061 77.314 5.800 0.000% 37 -5.976 -77.314 -10.352 5.976 77.314 10.352 0.000% -�-"--: - -_-- -Non-Linear Conver ence Results --- -`-_---- Load Converged? Number Displacement Force Combination ofCvcles Tolerance Tolerance I Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00000206 3 Yes 4 0.00000001 0,00000194 4 Yes 4 0.00000001 0.00000131 5 Yes 4 0.00000001 0.00000126 6 Yes 4 0.00000001 0.00000107 7 Yes 4 0.00000001 0.00000110 8 Yes 4 0.00000001 0.00000128 9 Yes 4 0.00000001 0.00000124 10 Yes 4 0.00000001 0.00000203 11 Yes 4 0.00600001 0.00000192 WxTower Job Page 100928.001.01 - TC SR-70, FL (Site# FL17050-A) 19 of 25 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone., (918) 587-4630 SBA Communications Corporation B. Sevier FAR.- (918) 295-0265 12 Yes 4 0.00000001 0.00000153 13 Yes 4 0.00000001 0.00000146 14 Yes 4 0.00000001 0.00000121 15 Yes 4 0.00000001 0.00000121 16 Yes 4 0.00000001 0.00000132 17 Yes 4 0.00000001 0.00000127 18 Yes 4 0.00000001 0.00000187 19 Yes 4 0.00000001 0.00000176 20 Yes 4 0.00000001 0.00000129 21 Yes 4 0.00000001 0.00000125 22 Yes 4 0.00000001 0.00000119 23 Yes 4 0.00000001 0.00000120 24 Yes 4 0.00000001 0.00000153 25 Yes 4 0.00000001 0.00000146 26 Yes 4 0.00000001 0.00000001 27 Yes 4 0.00000001 0.00000001 28. Yes 4 0.00000001 0.00000001 29 Yes 4 0.00000001 0.00000001 30 Yes 4 0.00000001 0.00000001 31 Yes 4 0.00000001 0.00000001 32 Yes 4 0.00000001 0.00000001 33 Yes 4 0.00000001 0.00000001 34 Yes 4 0.00000001 0.00000001 35 Yes 4 0.00000001 0.00000001 36 Yes 4 0.00000001 0.00000001 37 Yes 4 0.00000001 0.00000001 Maximum_Tower Deflections Service Wind Section Elevation Horr. - Gov. Tilt Twist No. Deflection Load ft in Comb. o ° T 1 250 - 240 3.322 34 0.149 0.036 T2 240 - 220 3.006 34 0.146 0.035 T3 220-200 2.423 34 0.118 0.032 T4 200 - 180 1.957 34 0.096 0.025 TS 180 -160 1.569 34 0.081 0.021 T6 160 - 140 1.240 34 0.068 0.017 T7 140 - 120 0.960 34 0.057 0.015 T8 120 - 100 0.719 34 0.048 0.012 T9 100 -.80 0.521 34 0.038 0,010 -TIO- --' 80-60-- - ---0357" -- - - - 34- - -- - 0.029 - '-- --- 0.008' - - - _ -- - - - ---- - -- - - T11 60 - 40 0.222 34 0.021 0.005 0.123- - 34- - - - - - OUY4 - "04____. ---Ti _ -_ Critical Deflections and Radius of Curvature-- Service Wind ; . Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature f Comb. in ° ft 255.000 Lightning Rod 5/8" x 4' on 6' Pale 34 3.322 0.149 0.036 186839 251.000 Strobe 34 3.322 0.149 0.036 186839 248.000 (2) CMA-BDHH/6520/EO-8 w/ 34 3.258 0.149 0.036 186839 Mount Pipe 125.500 Side Lighting 34 0.781 0.050 0.013 113280 WxL over Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 20 of 26 Project Date B+T Group 1717 SBoulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Maximum Tower Deflections -.Design Wind Section Elevation Hon-. Gov. Tilt Twist No. Deflection Load R in Comb. o TI 250 - 240 19.936 18 0.893 0.222 T2 240 - 220 18.043 18 0.875 0.215 T3 220 - 200 14.555 18 0.704 0.195 T4 200 - 180 11.762 18 0.576 0.154 T5 180 - 160 9.435 18 0.486 0.126 T6 160 - 140 7.459 18 0.409 0.106 T7 140 - 120 5.780 18 0.343 0.090 T8 120-100 4.338 l8 0.285 0.073 T9 100 - 80 3.146 18 0.226 0.060 TIO 80-60 2.161 18 0.173 0.047 Tll 60-40 1.348 18 0.126 0.033 T12 40-20 0.747 18 0.082 0.022 T13 20-0 0.305 10 0.041 0.011 Critical Deflections and Radius of Curvature = Desig in Wind Elevation Appurtenance Gov. Deflection Till Twist Radius of Load Curvature ft Comb. in 0ft 255.000 Lightning Rod 5/8" x 4' on fi Pole 18 19.936 0.893 0.222 31194 251.000 Strobe 18 19.936 0.893 0.222 31194 248.000 (2) CMA-BDHH/6520/EO-8 w/ 18 19.555 0.892 0.221 31194 Mount Pipe 125.500 Side Lighting 18 4.710 0.300 0.077 18919 !Bolt Design Data Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria No. Type Grade._ Of Loadper -Load- Load Ratio ft in Bolts Bolt K Allowable - TI -250 - Leg -- Ai7SN_ I I75 6 K 1171 67-09fi _ _✓ -- - I RnIRTr"a _nn - _ --- T2 _240. Leg A325N 1.125. 6. 13.060 67.096. 0.195 1 Bolt Tension T3 220 Leg A325N 1.125 6 17.546 67.096 0.262 1 Bolt Tension Diagonal A325N 0.875 1 4.235 11.166 0.379 1 Member Block Shear T4 200 Leg A325N 1.125 8 16.179 67.096 0241 l Bolt Tension Diagonal A325N 0.875 1 4.420 10.413 0424 1 Member Block Shear T5 180 Leg A325N 1.125 8 19.159 67.096 0286 1 Bolt Tension Diagonal A325N 0.875 1 5.167 13.884 0372 1 Member Block Shear T6 160 Leg A325N 1.125 8 22.174 67.096 0.330 1 Bolt Tension Diagonal A325N 0.875 1 6.095 17.355 0.351 I Member Block Shear WxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 21 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Section Elevation Component Bolt Bolt See Number Maximum Allowable Ratio Allowable Criteria No. Type Grade Of Loadper Load Load Ratio ft in Bolts Bolt K Allowable K T7 140 Leg A325N 1.125 12 16.870 67.096 1 Bolt Tension 0251 Diagonal A325N 0.875 1 7.270 15.244 1 Member Block 0477 Shear T8 120 Leg A325N 1.125 12 19.033 67.096 1 Bolt Tension 0.284 �/ Diagonal A325N 0.875 1 8.504 22.866 1 Member Block 0372 Shear T9 100 Leg A325N 1.125 12 21.311 67.096 1 Bolt Tension 0318 Diagonal A325N 0.875 1 10.000 22.453 1 Member Block 0445 �/ Shear T10 80 Leg A325N 1.125 12 23.694 67.096 1 Bolt Tension 0.353 Diagonal A325N 0.875 1 11.406 17.962 1 Member Block 0.635 Shear Tll 60 Leg A325N 1.125 12 26.159 67.096 1 Bolt Tension 0.390 Diagonal A325N 0.875 1 13.182 24.354 1 Bolt Shear 0.541 T12 40 Leg A325N 1.125 12 28.720 67.096 1 Bolt Tension 0428 Diagonal A325N 0.875 1 15.232 24.354 I Bolt Shear 0.625 T13 20 Diagonal A325N 0.875 1 16.848 24.354 1 Bolt Shear 0.692 Compression Checks Leg Design Data Compression Section Elevation Size L L. KYr A P. vtP„ Ratio No. P. ft ft ft in K K 60D„ Tl 250-240 - 2 1/4 10.000 3.083 65.8 3.976-21.391 130.399 0.164' K=1.00 V - - -- - --- T2----240-220 - - - - 21/2- - ---20.000- 3..208 -6L6-- 4:909-82.625 167.374- - 0.494'-- -- - K=1.00 I/ T4 200--180 - - 4 - - - 20.030 -6.176 - 74.1- 12.566 -135.211 378.448 0.357' - - K=1.00 V T5 180 -160 4 1/4 20.030 6.176 69.8 14.186 -163.640 447.281 0.366' K=1.00 `/ T6 160 -140 4 1/2 20.030 6.176 65.9 15.904 -193.191 521.096 0.371 ' K=1.00 V T7 140 -120 4 3/4 20.030 6.176 62.4 17.721 -224.217 599.797 0.374' K=1.00 9/ T8 120-100 43/4 20,030 6.176 62.4 17.721 -257.162 599.797 0.429' K=1.00 `/ T9 100-80 5 20.030 6.176 59.3 19.635 -292.242 683.313 0.428' K=1.00 I/ TIO 80-60 51/4 20.030 6.176 56.5 21.647 -329.438 771.566 0.427' K=1.00 j WxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 22 of 26 Project Data B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAR.- (918) 295-0265 Section Elevation Size L L; KI1r A P. OP„ Ratio Na. P. ft ft ft n' K K Tit 60 -40 5 1/2 20.030 6.176 53.9 23.758-369.358 864.519 0.427' K=1.00 T12 40-20 5 314 20.030 6.176 51.6 25.967-411.623 962.128 0.428� K=1.00 V T13 20 -0 5 3/4 20.030 6.176 51.6 25.967-455.600 962.128 0.474 ' K=1.00 `/ 1 P„ / n P. controls Diagonal Desi n Data (Compression) Section Elevation Size L L. Kl/r A P. �P„ Ratio No. P ft ft ft in° K K �P� TI 250-240 1 5.050 2.407 106.6 0.785 -4.228 13.997 0.302' K-0.92 t/ T2 240-220 11/8 5.128 2.430 101.8 0.994 -5.769 18.668 0.309' K-0.98 V T3 220-200 L2x2xl/4 7.558 3.628 113.5 0.938 4.569 15.422 0.296' K=1.02 6/ T4 200- 180 L2 1/2x2 1/2x3/16 9.676 4.625 114.1 0.902 -4.381 14.728 0.297' K=1.02 V T5 180-160 L2 1/2x2 1/2xl/4 11.213 5.383 131.6 1.190 -5.121 15.499 0.330' K=1.00 V T6 160-140 L2 1/2x2 1/2x5/16 12.851 6.192 152.0 1.460 -6.003 14.284 0.420' K=1.00 `/ T7 140 -120 L3x3xl/4 14.556 7.034 142.6 1.440 -7.172 16.000 0.448' K=1.00 V T8 120-100 L3x3x3/8 16.306 7.911 161.7 2.110 -8.340 18.227 0.458' K=1.00 T9 ( 100-80 L3 1/20 1/2x5/16 18.081 8.787 152.8 2.090 -9.765 20.218 `/ 0.483 ' K=1.00 __ T10 80-60 IAx4xl/4 19.885 9.680 146.1 1.940 -11.248 20.530 0.548' - - -- r � Tll 60=40-IA5E43378 - -21:709 `10:581--161:1--2:860-- --I2:943-`24:8830:5201-"- --- - - - - - - - K=1.00. V T12 40-20 L5x5x5/16 23.546 11.490 138.7 3.030 -14.796 35.576 0.416' K=1.00 `/ T13 20 -0 L5x5x5/16 25.395 12.415 149.9 3.030 -16.429 30.474 0.539' K=1.00 1 P. / �P„ controls Wx ower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 23 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Top Girt Design Data (Compression) Section Elevation Size L L„ Kl/r A P. r P. Ratio Na. P. ft ft ft tR K K r P- TI 250-240 1 4.000 3.813 128.1 0.785 -0.065 10.727 0.006 K=0.70 V T2 240-220 1 1/8 4.000 3.792 113.2 0.994 -1.521 16.396 0.093 K=0.70 t/ I P. / e. Controls Bottom Girt Design Data (Compression) Section Elevation Size L L. K1/r A P. i1Pq Ratio No. P. h Tl T2 240 - 220 1 118 I P. / �P„ wntrO1S ft ft in2 K=0.70 V 4.000 3.792 113.2 0.994 -0.218 16.396 0.013 K=0.70 V Tension Checks Leg Design Data Tension Section Elevation Size L L. KI1r A P. rpp„ Ratio No. P. ft. ft ft- - in' K K 0P: TI 250-240 21/4 10.000 0.375 8.0 3.976 19.049 178.924 0.106' - - - - - - - --4:909-- 78.362-- -220.893--0:355 - -- --- ---- T3 220-200 3 1/2 20.030 0.751 10.3 9.621 105.276 432.951 0.243 T4 200 - 180 4 20.030 0.751 9.0 12.566 129.430 565.487 0.229 TS 180- 160 4 1/4 20.030 0-751 8.5 14.186 153.275 638.381 0.240� T6 160 - 140 4 1/2 20.030 0.751 8.0 15.904 177.393 715.694 0.249 T7 140 - 120 4 3/4 20.030 0.751 7.6 17.721 202.442 797.425 0.254 T8 120 - 100 4 3/4 20.030 0.751 7.6 17.721 228.401 797.425 0.286 ' MxTower MxTower Job - TC SR-70, FL (Site# FL17050-A) Page 24 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 S Boulder Ave, Suite 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX.- (918) 295-0265 SBA Communications Corporation B. Sevier Section Elevation Size L L„ K1/r A P. �P, Ratio No. P. ft ft f in' K K OP, T9 100-80 5 20.030 0.751 7.2 19.635 255.733 883.573 0.289' T10 80 -60 5 1/4 20.030 0.751 6.9 21.647 284.328 974.139 0.292' T11 60-40 5 1/2 20.030 0.751 6.6 23.758 313.909 1069.120 0.294' T12 40-20 5 3/4 20.030 0.751 6.3 25.967 344.639 1168.530 0.295' T13 20-0 5314 20.030 0.751 6.3 25.967 376.311 II68.530 0.322' P. / �P„ controls Diagonal Design Data Tension Section Elevation Size L L„ KI1r A P. r P„ Ratio No. P. ft ft ft in' K K op, TI 250-240 1 5.050 2.407 115.5 0.785 4.213 25.447 0.166' T2 240 -220 1 1/8 5.128 2.430 103.7 0.994 5.710 32.206 0.177' T3 220-200 L2x2xl/4 7.558 3.628 75.2 0.516 4.235 22.446 0.189, T4 200- 180 L2 1/2x2 1/2x3/16 9.676 4.625 74.2 0.536 4.420 23.311 0.190, T5 180-160 L2 1/2x2 1/2xl/4 11.213 5.383 86.9 0.705 5.167 30.668 0.168' T6 160-140 L21/2x21/2x5/16 12.851 6.192 100.6 0.861 6.095 37.437 0.163' T7 140 -120 L3x3xl/4 14.556 7.034 93.2 0.892 7.270 38.824 0.187' T8 '120-100 L3x3x3/8 16.306 7.911 106.4-- 1.301 8.504 56.604 0.150' T9 100=80 L�3-t12x7-t12x5it6-18:081-8:787-99:7-1-.333-10:000 57:991-0r172a _ T10 -80-60 L4x4xl/4 -19.885 9.680 94.7 1268 11.406 55.136 0.207' Tll 60-40 L4x4x3/8 21.709 10.581 105.1 1.864 13.182 81.073 0.163' T12 40-20 L5x5x5/16 23.546 11.490 89.3 2.038 15.232 88.658 0.172' T13 20-0 L5x5x5/16 25.395 12.415 96.3 2.038 16.848 88.658 0.190, I P. / �P„ controls WxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 25 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone. (918) 587-4630 SBA Communications Corporation B. Sevier FAX. (918) 295-0165 Top Girt Design Data Tension Section Elevation Size L La Kl/r A Pa 6P, Ratio No. P.. in' K K T2 240-220 1 1/8 4.000 3.792 161.8 0.994 1.523 32.206 0.047600, 1 P a / �Pa Controls _ Bottom Girt Design Data; (Tension). Ratio Section Elevation Size L La KI/r A P„ QP„ No. P. ft ft ft in2 K K V. TI 250-240 1 4.000 3.813 183.0 0.785 1.202 25.447 0.047 ' 72 240-220 11/8 4.000 3.792 161.8 0.994 0.083 32.206 0.003' V 1 P u / r Pa controls Section Capacity Table Section No. Elevation ft Component Type. Size Critical Element P K ePall .. K % Capacity Pass Fail TI 250-240 Leg 21/4 1 -21.391 130.399 16.4 Pass T2 240 - 220 Leg 2 1/2 28 -82.625 167.374 49.4 Pass T3 220-200 Leg 3 1/2 73 -106.954 256.230 41.7 Pass T4 200- 180 Leg 4 94 -135.211 378.448 35.7 Pass - -T5---180.=160- - -Leg . - - - 4-1/4- -- - -115 - --163.640- -447281- 36:6- - Pass- - T6 160 -140 Leg 4 1/2 136 -193.191 521.096 37.1 Pass _ T9_ _ _ 100 - 8.0 _ _ Leg. _ 5 199 -292_242 683.313 _ 42.8 Pass TIO 80 -60 Leg 5 1/4 220 -329.438 771.566 42.7 Pass Tll 60-40 Leg 51/2 241 -369.358 864.519 42.7 Pass T12 40-20 Leg 53/4 262 -411.623 962.128 42.8 Pass 42.8 (b) T13 20-0 Leg 53/4 283 -455.600 962.128 47A Pass TI 250-240 Diagonal 1 15 -4.228 13.997 30.2 Pass T2 240-220 Diagonal 1 1/8 42 -5.769 18.668 30.9 Pass T3 220-200 Diagonal L2x2xl/4 92 -4.569 15.422 29.6 Pass 37.9 (b) T4 200-180 Diagonal L2 1/2x2 1/2x3/I6 101 -4.381 14.728 29.7 Pass 42.4 (b) T5 180- 160 Diagonal L2 1/2x2 1/2xl/4 122 -5.121 15.499 33.0 Pass 37.2 (b) T6 160-140 Diagonal L2 1/2x2 12x5/16 143 -6.003 14.284 42.0 Pass T7 140-120 Diagonal L3x3xl/4 164 -7.172 16.000 44.8 Pass ower Job Page f.:hj 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 26 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Section No Elevation ft Component Type SLe Critical Element P K opy. . K % Capacity Pass Fail 47.7 (b) T8 120-100 Diagonal L3x3x3/8 185 -8.340 18227 45.8 Pass T9 100-80 Diagonal L3 1/2x3 1/2x5/16 206 -9.765 20.218 48.3 Pass T10 80-60 Diagonal L4x4xl/4 227 -11.248 20.530 54.8 Pass 63.5 (b) T11 60-40 Diagonal L4x4x3/8 248 -12.943 24.883 52.0 Pass 54.1 (b) T12 40 -20 Diagonal L5x5x5/16 269 -14.796 35.576 41.6 Pass 62.5 (b) T13 20-0 Diagonal L5x5x5/16 290 -16.429 30.474 53.9 Pass 69.2 (b) Tl 250 -240 Top Girt 1 5 -0.065 10.727 0.6 Pass T2 240 - 220 Top Girt 1 1/8 32 -1.521 16.396 9.3 Pass T1 250 -240 Bottom Girt 1 8 -1.196 10.727 11.2 Pass T2 240 - 220 Bottom Girt 1 1/8 36 -0.218 16.396 1.3 Pass Summary Leg (T2) 49.4 Pass Diagonal 69.2 Pass (T13) Top Gut 9.3 Pass (T2) Bottom Gut 11.2 Pass (Tl) Bolt Checks 69.2 Pass RATING= 69.2 Pass Program Version 6.1.4.1 - 12/17/2013 APPENDIX B BASE LEVEL DRAWING Feed Line Plan B+T Group 1717 S Boulder Ave, Suite 300 BST GRP Tulsa, OK 741 Phone: (918)587-4630 FAX: 918 295-0265 Job: 100926.001.01- TC SR-70, FL (Site# FL17050-A) °mje` G1-" SBA Communications Co oratio 8' D1e by. B. Sevie Mp¢ coae_ TIA-222-G oeIe: sale: 09/04/15 NTS P8N: D N N.. B-7 APPENDIX C ADDITIONAL CALCULATIONS r PROJECT TC SR-70 - FL37050-A, FL SUBJECT Anchor Rod Check for Self Supporting Towers DATE 09/04/1S PAGE 1 OF 1 Number of Anchor Rods Diameter: Strength (Fu): Eta Factor, rl: Down load, Pu: Shear, Vu: Anchor Rod Result Max Rod (Cu+ Vu/r ): Allowable Axial, 0)*Fu*Anet: Anchor Rod Capacity: �FB+T GRP 1717 S. Boulder, Suite 300 Tulsa, OK 74119 (918) 587-4630 12 1.375 in 105 ksi 0.5 TIA-222-G Figure 4-4 & Section 4.9.9 463 Kips 47 Kips 46.4 Kips 97.4 Kips =47�6 —.=— Pass 55 Drilled Pier Site Number: TCSR-70 Site Name: FWOSG5 A, FI Input TIA Revision: G AC1318 Revision: 2008 Seismic Category: B Compression 463 kips Compression Shear 49 kips Uplift 375 kips Uplift Shear 39 kips Add'I Moment 0 k-ft Swelling Force 0 kips ' Faunddtlair Oimerlslorrs Pier Diameter: 12 ft EA. above grade: 0.5 ft Depth below grade: 35 ft Bell Diameter. ft Bell Angle: deg Mat'enaTPropeNes Number of Rebar: 90 Reba, Sire: 9 re Size 4 Rebar tensile strength: 60 ksi Concrete Strength: 3000 psi Ultimate Concrete Strain 0.003 in/in Clear Cover to Ties: 6 in 5oifPmfile goili T� To Data: a6"CC SP,T'N'. Lobnis -`-_2_.-'4'i-'-.'t `-' -`5 - 53- --'01; -'0 0 -. 0____.. a___ �... ._ 3 1 5 6 57 Iwo 0 0.4 0.4 D .._57 _-0 __....40 ... -0.4.. 0.4 _. "0-_.., .. _.... .___..._. 5 2 _. ...__.___.__-,_.v,_ - 8 10 .. 52 _._.,_ 3000 _ _ 0 .__ _ 0.4 _..—. 0.4 _-.__.. � 0 ._._,30 __ 29' __ ...SJ ._ .. 0 - -35 ._ "-08 _. .__._._•.0.8_ _ _0_, .. _ 7 Analysis Results Soil lateral Capacity Uplift4ase'. Soli Axial Capacity Cq'haete VJeiglilT 326.Skips Skin Faction: 656.0 Gips Soil Cone: kips Uplift Capadiry'(k), Vm 982.0 kips Uplift(k),Su: " 375.0'kiP5 _ SddFiidion (k)( -� ------6560 kips - End Bearing (k): 1696.5 kips I Camp: Capacity(k), �Cm 43524 kips ComR. (k), Co: 463.0 k Ps .. _ "IRATING: 19.689�"`_.. _ ^ Concrete/Steel Check Uplift Czse - Compase, p Mu (from soil ahalysa) -- 4159 k-ft "" 593.5 k ft 17.2 ft -- - - mMn - 236231 k-ft- 26249.9 k ft 523.5 k-ft 1 IRAPNG- ""230%--2:18% y✓ provided -- ----- _rho rhorequired: AP, RebarSrdu g 3-4 Spadngrequired - 18.0 OK DO- lengthrequlred- -1)3 Dev.ledg[h provided 49AUK—�-`,� --luveraill Foundation Ra Ing:- Page 1 of 1 PROJECT 100926.001.01 - TC SR-70,FL BWS SUBJECT Pad Footing Analysis DATE 09/04/15 PAGE 1 OF 1 JimB+T GRP 1S. Boulder, Suite 300 Tulsuls a, OK 74119 (918) 587-4630 Combined Footing Foundation Analysis Design Loads: Saftev Factors Rev. Type: G Input factored loads Compression per leg (Pc) = 463.0 (k) Tension per leg (PT) = 375.0 - (k) Overturning Moment (MO) = 9,347.0 (k) Total Tower Horizontal Load — 79.0 (k-ft) Tower + Appurtenances = 93.0 (k) Pad & Pier Dimensions / Properties: Tower Shape (triangle or square) — T Pier Shape (round or square) = R Pier Diameter ( Hp ) = 3.00 (ft ) Pier height above grade ( Dp) = 0.50 (ft ) Footing Width ( WF ) = 47.00 (ft ) Footing Thickness ( HF) = 3.00 (ft ) Depth to BOC ( D) = 7.00 (ft ) Concrete Strength ( Pc ) = 3.00 ( ksi ) Rebar Strength ( Fy ) = 60.00 ( ksi) Ultimate Load Factor = 1.30 Min. Cover over Rebar = 3.00 ( in ) Qty of footing Rebar (1 layer) — 47 Size of footing Rebar — # 9 ( bar ) Qty of Vertical Rebar per Pier = 33 Size of Pier Vertical Rebar — # 9 ( bar ) Qty of Rebar Ties per Pier — 11 Size of Pier Rebar Ties = # 4 ( bar) -- -I -Soil bearing -(ultimate) - - - - _ - 4000— (-psf ) Soil Cone for Uplift (B) 30 ( degrees ) Cohesion (C) 0.00 (ft ) Top Soil to Neglect ( N) 3.00 (ft ) Base Sliding (p) = 0.35 ( ksf ) Dry Soil Density ( ypay) = 63 ( pcf ) Uplift S.F. (Cons. Wt.) = 1.25 Uplift S.F. (Soil Wt.) = 2.00 Overturning S.F. = 1.50 Bearinging S.F. _ - 2.00 _- Tower Information Tower base width = 25.00 ft Plan View for Triangle or Square Tower f!M! _I 1 HF i 'L F_ Summary of Results Overturing 42.6% Soil Bearing 34.7% Base Sliding 16.8% One way Shear 8.3% Punching Shear 42.6% Pad Moment Capacity 47.0% Pier Moment Capacity 12.5% Kimley) Horn August 12, 2015 MetroPCS Attn: Denise Correa 1000 Sawgrass Corporate Parkway, Suite 400 Ft. Lauderdale, FL 33323 RE: Antenna Mount De-s'M 'Letter SCANNED By St. Luce County Carrier Designation: MetroPCS 760:MU Upg ade. Carrier•'Site Number: i92P0309M Caiiier.4iteNaM6 GTPWLNY7�0 Site Data: 20000.0keechobee Road Fort Pierce; FL34§49, St. Lucie"County To whom it may concern: In accordance with our agreement, Kimley-Horn and Associates, Inc. ("Kimley-Horn"), has performed an evaluation of the existing antenna mount for the above referenced site for the replacement of MetroPCS antennas. The purpose of this analysis is to compare the existing manufacturer's mount design specification with the proposed carrier loading conditions to determine if the proposed mount is structurally capable of supporting the proposed MetroPCS equipment under the loading of the TIA-222-G standard and the 2014 Florida Building Code. The proposed mount was checked against the required 117 mph nominal design wind loading (151 mph ultimate wind speed, Risk Category II, Exposure C per 2014 Florida Building Code). Per the specifications provided by MetroPCS, the existing and proposed antennas are as follows: • (Existing) 6- CMA-BDHHI6520/EO-8 antenna:'64.6"x 15.W x 5"; 62 Ibs - — • (Existing) 3- FRIE RRU's: 19.3" x 22" x 5.2"; 55.1 Ibs • (Existing) 3- FRIG RRU's: 15.24" x 18.88" x 5.98"; 57.3 Ibs • (Existing) 3- FRLB RRU'st 15.75" x 15.75" x 5.9"; 59.52 Ibs • (Proposed) 3- DBXNH-6565B-A2M: 72.7" x 11.9" x 7.1"; 46.3 Ibs The existing mount, a Connect -It Wireless, 13' V-Frame Boom Gate, VF13-XX-96 is to be reused. Conservatively, no shielding is assumed on the RRU's. The COVP's are considered to be on a separate mount. kimley-horn.com-1920'Wekiva Way, Suite 200, West Palm Beach, FL'33411 561 845 0665' Kimley»>Horn Page 2 Based on the comparative analysis listed below, it is our opinion that the existing mount will have sufficient capacity for the proposed carrier equipment. Please contact me at (561) 840-0232 or Kevin.Maraiti(ftimley-horn.com should you have any questions. Sincerely, KIMCE)rilORN AND ASSOCIA°TES; (NC: CA 00060696 1 IVIIUQ r.L. / IYVU/, /IIIIIIII1\ Attachments: - Kimley-Horn 700-MHz Upgrade Plans dated November 26, 2013, Sheet C-2. Connect -it Wireless 13' V-Frame Boom Gate VF13-XX-96, Design Specifications. 2014 Florida Building Code -Building Section 1620.2 RFDS Data Configuration Sheet Page 1 of 4 U...: YALWASH — -Mobile' L]r` lack to RFDS home RFDS Data Configuration Sheet Dale: 7/2712016 to Back 'Print RFDS Site Information: :Atnymt FL :Radio Vendor. �NSN Plan Year, 2f114 NLPDeeC: OWSMe appOved pohg0n ISH.Ur "00991 isle Nalm: WBW-3_200-WPHWY70 Clmdamlovmer. iTYPetc_la:s:_. Stmeture lNn?BMeln9)l salt SW,aATMgT,.- ' _.__.. _.... .... .. ... _.. _._.. ....... ... ;Address: 2a9¢¢OkeeHmbeaRoad (SR]0) Gty Fort Pieme SNta:, FL Zip: 31945 latltdds 27AM0957 ,..__ilnngRede;=,: Id0.57965a2 Crea@d Date: Jun2a2014.,.. RFMana.er. Armand Gmymmteyn :pF Eashur. ., Ayad ataddar last save Date:Jul n 20164:lVM Iasi Modirad Fly. YP1WAsd Project Type: 1.70011.1900 RFDS Upgraded? Upgraded Template? Standard Cell Site Configuration Configuration Type: Canri9OmLmh701A_OUSy ;L7WAmmma Wotic SWAP Flnal Confiaaailen (AntammA.InPRNA1RRUi: 9161019 „-ISelutiOn Tyne: Tozer TOP pF0.n SMIOe: PmOminay_______.__,-...--. :Float Setter Count ] IDealan Type: Final UmwinO TYPe: Cualhm Sectorinformatlon MPCS CDMA Design A B C D E F :AFlmaa Me Centel: �Demm Decom .,.,,-, Dowm ._....__... IMachenmal❑Ib s.._____..._.. I .:. _. ___.__.__... _.— ..... ... . ....... .. .._.. _ _. ...........__ ._.... ...... _._ _. ilhcviaai Tin: .. PCS UNITS Design A B C D E F .amwna MD choler: xtp..._._, 12ae-.-,.,24e-, _ --------- �Ananna Arhnam: i za ! 0 240 .rlealnaal nli: %2, :.z 2 ... AWS UMTS Design A B C D E F .Antenna RAD center. I249... _, NS, 249 Mechanlwl TlL' le '0 .. ...... a .i ... .EIedR ITI¢ 12 :2. - 3 . .._.... ._... ' L2100 Design A B C D E F :Antenna Me Center. IT/s ' 124e ___..._....... _.. 24e .. .. ... . ...... .. ... .. .._..... .. .. _. ... ...... .,,. :Antenna Azimuth: �20 .95 . .. 0 iDa_atRcal TJt 14 !3 2 .. L700 Design A B C D E F :Antenna FADCanten 1246 �218 Ne a iAmm�na AalmuO: 120 .25.. 240 „ :Mulm.l.ml TIN: ... _ 10 '..a ......... :. :. 0: FJeurlW nm 8 a 4 - Antenna Configuration (Site Level) Antenna ReUse Antenna Model Antenna Qty Antenna and (or) Ports Shared E ISUng?tQty MPCS CDMA .S_—___.- _:_. ... ... ...............__.....___ --- —------ __. .... oewm ..... .__.... _.._. --- MS UMTS IRa.Uae EtlalNgl3 - CeW.- CMAEDH14e52W£0­0 - 3 NO AWSUMTS ,NewlO __..._..._.... fAndrrn-OBXNH-05658 A2M ..... _. - .0 .__. .... _.. __—._. ............... Bbamwim... ..... L2100 IRe41sh FJtlsEngl3 . _ �CefMax-CMA410HW85z11(E0.e :3 ... .. .. .. .... :. No Pod Sham - V00 p.. (Now.a_„ AMrrn ABXNHd5656A2M 3,.. .., ShamwlM1 Uz100 -. TMA(ReUse ]AM conrwrenon(She ie.eg existing TMAINM/Not TMA Model TMA cry TMA Location Needed) "US COMA PeSUMTe AWS UMTS wao L700 ._.. :DlPleaerQryltl: i {CombinerAIDplenW Model:_,_...__.... :COmbInmlDUPiexer0.ry: .. .. .. Antenna Fibe r Coax Solution(Ske'Loveli iuse HCaryulbio)] Uah NSNMar&OW for ROWWP IN. Sae .U. Chou, CdoCablerya (_. ..... . ..... .... .. . a ealNPl] Hybrid Cable Configuration (Silo Level) �Hybrrd cable Type: :Hybrid Cabla LangN: 1300 'Hybrid Cable etr. .... ... .. _ .._ .... _ .. Hybrid Cable Config(Sector Leval) A B C D ._..._._.._._.i E F http://natdev.eng.t-mobile.com/Central/RFDS/RFDSPrint.asp?Siteid=A2P0309Vi_F_UG 7/27/2015 RFDS Data Configuration Sheet Page 2 of 4 HCe MR bvt mn SmI*M(e.g Ro¢flePl Ztentank nay Hybtltl Cable Lengm (fll_ COVP Configureflon (Site Level) .coW.Twelf@_... . i Lalpe cow .............. .. cow otX(fF.:I 'Cawiype R): Lag- row CCVP My (2), a ... .. Coax Configuration A B C D E F :Fxisnn9 Cnaa CM 112 :2 2 !Etlsnnrc.She: 161a (1S2 Gry.at excess wax We¢¢o rsmovet _„ 'Naw iNew Co Lens],Wne: ... . �Naw CvxCy:. _. .. _. ........... .._..:�.... - '__._............ ... .._ ... ..... ._......... ... ... ... ..... !RET N¢meRun Cables ` ! _.. __....._. _... . . __ __... ... _._ _ ........ .. _.. ... _... iRET XomeAvn Cable Lnnetbgt} _ .._..._.. _...__ .... .. . http://natdev.cng.t-mobile.comICentraliRFDSIRFDSPrint.asp?Siteid=A2PO309M_F_UG 7/27/2015 RFDS Data Configuration Sheet Page 3 of 4 System Modules (Site Level) System Module System Module sty System Module System Module Mode a Type Mode a sty MPCS COMA PCSUMTS FSMF .i Me UMTS iFSME d LTE iFSMF.1 RF Modules (Site Level) Ri, Module Type RF Module Qty(1) RF Module Type(2) RF Module Qty(2) MPCS COMA PCs UMTS FM 3 AWS UNITS ME 3 L21eo :FRIG 3 ! LT00 'FRLB :3 Sector/BTS/Node-B (Site Level) Sector Count: BTS/Node-B Count MPCS COMA PCSUMTS �:3. 1- AWSUMTS i3 it L210C 3 I1 .. ......... .. . Ly0n .... .... ....... ........ :3 .: 1 Comments 0mlTRote: Upeated Ne RAD waterfmm236 W 248 as per Ne SACNformagoe 'Anlwna helgMverif alien roan wmp@led by Jacobs. �tER312018: RFOSb .prated In awommod de 1.700. :Ws k a Me0p keep 3sectors Ste. My modernized, wewill dswm CDMAand swap ouleailNg quad aMermas sunenilyspartd behveen CDMAand WIM iFor Quad L?W wmpa4blata be shared behewn U2100 and L700. WewUNg211 LT00 radios as 08 end use Ore Was harvaasE Gam COMA. 'Um00 hwn5gwed IS have2danlers andcan be upgraded 1o3 carriers une, ebslidg a 1pmerA(FSMFIFBBP/FXF@ UVO b conGgursdw3629 MHz, WMIM0. Note SNce coaslength a less Nan 27C, no TMAis mgWred OF (3dnlbp, Ian arousal FBBA/ 11900 _,1 FSME/Mi(s).1 MW ♦ 1 FBSA e 1 FE9CTt2100 MA ells eweaping Nempenot on ground)(eainNg) .,,1 FSMETIld10o„1 PROF ♦ 1 FBBAS 1 FBMIL2100 (eealhy) http://natdev.eng.t-mobile.com/CentraVRFDSIRFDSPrint,asp?Siteid=A2PO309M_F_UG 7/27/2015 RFDS Data Configuration Sheet Page 4 of 4 SIN: A2P0309M - Configuration Drawing 1 Drawing (1) Comments: New [gNymeN _.__.UP9mded egwpment '.. Rewnpqu,ed �l l equipment , `a http://natdev.eng.t-mobile.comICentraURFDSIRFDSPrint.asp?Siteid=A2PO309M_F_UG 7/27/2015 KimleyoHorn MetroPCS 700 MHz Upgrade A2P0309M 7 GTP HWY 70 Antenna SDecificabons Find wind areas on proposed antennas to check proposed mount capacity. EquipmentVe: 6* Total number of Appurtenances i := 0.. EquipmentVe — I * 0.. EquipmentVe — 2 ui .No. Name Hei ht Width Depth Weieht EquipVe0:= "CMA-BDHH/6520/EO-8"* HVe0 64.6in WVe0:= 15.9in DVe0 5in WTVe0 621bf EquipVel "DBXNH-6565B-A2M"* HVeI 72.7in WVeI := 11.9in DVeI := 7.1in WTVe1 46.31bf EquipVe2:= TRIG" * I1Ve2 15.24hVrVe2� 18.88inDVe2� 5.98inWTVe2� 57.31bf EquipVe3°FRIE"* HVe3 = 19.3in WVe3:= 22in DVe3:= 5.2in WTVe3 55.I1bf EquipVe4'= FRLB* HVe4� 15.75iiWVe4� 15.75inDVe4:=5.9in WTVe4� 59.521bf EquipVe5.— FXFB HVe5 5.2in WVe5:= 17.6in DVe5:= 15.6in WTVe5:= 55.11bf Area F.:=HVe.•WVe. Page 1 of 3 Date: 8/7/2015 Designed by: CRM MetroPCS 700 MHz Upgrade KAmley*Horn GTPHWY 0 Notes: 1. SectorA is considered to be the maximum loading case scenario. 2. Conservatively assumed no shielding of the RRU's. Only the TMA's are assumed to be shielded in this analysis. 3. The COUP is considered to be on a separate mount. Proposed ITV -Frame Boom Gate Specifications Proposed Platform a Connect -It Wireless 13' V-Frame Boom Gate, VF13-XX-96. Max Combined Load Weiebt Max Area Mount0 WF13-XX-96" WTVF13:= 6501bf AreaVF13 5600in2 Proposed Final Configuration - Per Sector Sector A• (2) CMA-BDHH/6520/EO-8, (1) DBNXNH-6565B-A2M, (1) FRLB, (1) FRIG, (1) FRIE, (1) FXFB Areamax :_ (2Area_F)0 + Area_FI + Area_F2 + Area F3 + Area_F4 + Area _F5 = 3971.32 -in WeighlmILK:= (2WTVe)0+ WTVeI+ WTVe2+ WTVe3+ WTVe4+ WTVcS= 347.321bf -Resin - - - -- - - - WTResult; t WT > Wei t ,"Pass':' 'Tad' "Pass"' AteaResult Area,Fl3>A!aiaa� 'Pass" '.Fare' '.amass"_. Page 2 of 3 Date: 8/7/2015 Designed by: CRM I I axAne I sing e n�riu:b r ANTENNA ORIF ATON DIAGRAM c vm m er xsee'�nou,wm u �/ IM1M1CL N 1 P �rAOp0. ll m- lll,� 1 aexm ro ee wssJ vo-, visRa J-+�rmaw a,.oa e.mrEo.o ¢ rdv... mo.P�a un limuinwic'�a?'i v�iam' mru�e metroPCS FLORIDA, LLO. ,Jm vmav mornae.wwru, mRR.w rt. wvaiwc n fvn 'RWELf IRM1ORWfMRt M FL-5302 FL-880, A2PO309M Msml.P M 25 NOVEMBER 2013 sum w IW UR�UUE ATE 0- WlS'PRPLId Bl .. ❑�❑'Riclr;n Y.cm r mtl Afv,cEle2, N raly vSLVP WAY, 2':IE aN Ms(rYW FlA➢4 ieWN1 JN�I llY mF-fWPI YGW (f6r)va5-W,If 0� d P�w�v�M9iuumixn�OIX�MN,wN wort u,mw�'curm 4 wiwvr°a�"6cw DETAILS AND TOWER ELEVATION r xlAmea—_.�.a�mswn C 22 dm F. 041417163 4 3 2 1 PENSION STATUS OF SHT I 2 3 4 5 6 7 REV WC N/C N/C WC N/C N/C N/C NOTES: I. ALL STRUCTURAL STEEL SHALL CO qM TO ASTM A36 GRADE O 2. ALL CONNECTIONS SHALL CONFORMS O AISC MANUAL OF STEEL CONSTRUCTION ALL BOLTS SHALL BE A325-X; 6145 15 SHOWN ON DRAWING. ALL RODS SHALL BE ASTM A36; SIZE PAS SHOWN ON DRAWING. 3. ALL STRUCTURAL STEEL 51-IALL BE ABRICATEO TO FIT AT BOLTED CONNECTIONS WITHIN Ill INCH TOL RANGE 4. STRUCTURAL STEEL SHALL NOT BE 1 LAME CUT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGIN ER: S. ALL WELDING SHALL BE DONE BY AN AWS CERTIFIED WELDER AND IN COMPLIANCE WITH AWS OR ALL V ELIop SIZES SHALL BE THE MAXIMUM ALLOWEDBY THE MATERIAL BEING ED WITH 0.30 WIRE WIRE -WELD. 6. HOT DIP GALVANIZE ALL STRUCTURL ,STEEL. TOUCH UP ALL FIELD WELDS AND ABRADED AREAS WITH TWO C AT5 OF, .GALVANIZED PAINT. dQAD 7. DO NOT EXCEED THE FOLLOWING, L WEIGHT & AREA LIMITS MAX. COMBINED LOAD WEIGHT 650 LOS. L MAX. COMBINED LOAD FORCE (P-, 1 2,765 LBS. MAX. COMBINED LOAD AREA AT 81 MPH (V ULTI OR 140 MPH (V ASM 7,945 SO. -IN. MAX COMBINED LOAD AREA AT 1 4 H (V ULT) OR 150 MPH IV ASO} 6.910 SQ.4N. S. -LOAD AREA' IS LARGEST X•SECTION; ArxF OF ANTENNA. 9. LOAD RATING DETERMINED IN ACCORDANCEWITH T1A•EIA•222-G-2, FLORIDA BUILDING CODE 2010, 'A AS.CE. 7.10. IQ ALL 1/2- FASTENERS MUST BE TOR UED so-60 FT:-LBS. 11. ALL 5/8" FASTENERS MUST BE TORQUED 100-120 FTA-ES. 12 ALL 3/4- FASTENERS MUST BE TO QUED 175-195 FT. -CBS. 13, MIN 2 STIFF ARMS REOD. FOR LOA & WIND RATING. 14. AVERAGE ASSEMBLY WEIGHT : 562 LOS. B MAX. PROJECTED ASSEMBLY AREA ' 2,711 50. IN. IEPATI MAX. NORMAL PROJECTED ASSEMBLYAREA- 1289 Sa IN. IEPAM �RO ANGLE PROJECTION AgWcQ �^I A ,L_,,, —,. �, FRAM( ANDRE I FORE, RE DATE LI OEgGN Q mot PIi'CPARED UN NH C M=r 571UCNRES ETJGNEF3l a APAFTSMPROVED LIC. N0. SEAL flAN95F® UM]Bi CtlNiNACf APPROVED BY. I JOB N¢ 13EN0028 SHEETS 8 9 10 B 12 q ONNOE rv¢ cEsaxvn°N DAMumovm N/C N/L WL N/C N/C N/C il G C B A SpcP� S ? U15H eLAL MP ZL f 23 GPIsa25 Pu'E 2.1/2" SCIi40 A36 GALV. STEEL t 22 P5204 PIPE SADIXE A36 GALV. STEEL 2 21 BAKI50 STIFF ARM KIT VARIOUS NOTE 13 10 z 12 1 118144 12NA I NUTIEX• 1/2"•13 NOTE 10 10 2 12 1 1 f8l 1 1 43 w I WASFE$LOCK- 011T q 2 2 za 42 WTE ' 1/2 1 al Ue12.FW 2-25 - 1--o NOTE 10 10 20 U912.25.4 uBa SET- Z112"x4" VARIOUS NOTE 10 1 40 UBi2-3a514.1 UAOLT 1/7-13 NOTE 10 to 9 UB12-30514 U-BOLT SEr- 3"x5.1/4 VAROUS NOTE 10 4 4 39 12112BA I BOLT- 1/2--I3xW2' NOTE 10 1 2 38 MSBA BOLT- 1/2'13x6' NOTE t0 4 t8 GRI2.6 ROa 1/2'43W NOTE m B n GR -14 ROD. OV2'-13)14' NOTE 101 12 12 37 58NA NUT)iEX- 05/8'•9 NOTE 0 12 t2 36 S8LW WASHER OCK- 5/8" 24 24 35 58FW WASHER FLAT- 5/B- 12 21 34 58209A BOLT- 5/8"•tIY2" NOTE 11 2 2 1 33 34NA NUTHE(_ 3/4"-t0 NOTE 12 2 2 1 32 1 34LW WASHER OCK- 3/4' 1 1 14 a 1 31 1 34FW WASFERl•1AT• 3/4' 1 1 12 2 1 30 1 342149A BOLT- 3/4'AW25' NOTE 12 5 16 ANW96 PIPE• 2-3/8' SCH40 A36 GALV. STEEL. 5 15 GP9B•30 PIPE• 3- SCH4o A36 GALV. STEEL 1 1 4 4 114 1 R013.O2 ANGLE• 3/16 x2"x2" A36 GALV. STEEL 1 1 2 2 113 1 VFI301 ANGLE- 1/4'x3-x3- A36 GALV. STEEL 2 2 111 ASWG WELDED GATE VARIOUS 2 2 II O FOOT FS-FA-UFS+AP OTTADPTUBEFAFOOT 2 9 UFSFA-W FOOT PLATE A36 GALV. STEEL 2 1 B. UFSfA-02 FOOT 50 TUBE A36 GALV. STEEL 2 2 7 UFSFA OOT ADAPTER YARIOUS 2 6 CFBC CLAMP FOOT BACK A36 GALV. STEEL 1 5 CFM-HO CLAMP FOOT- MULTI VARIOUS 1 4 CFSfD CLAMP FOOT" SINGLE VARIOUS 1 1 3 UFSHO HD UNIV. FOOT SET VARIOUS 2 VF13-25.96 IT V-FRAME 2.3/8' MAST VARIOUS NOTE q Nz 1 VF13-30.95 IT V+RAME 3" MA5T 1 VARIOUS NOTE 13 21 20 19 UNITS/ASsY 7 3 12 1 1 O A FAYI NO 2WE PART M IG6YIFliNG N6 NQ.4NMTURi NATFNR RFM/fIXs GAG ROOTS 177 US HW3 GIVE TA, L33469 A Sll M TEOUE 156 74 0510 USA 1560 744�0510 CONNECT -IT WIRELESS, INC VF13-xx-96 13' V-FRAME BOOM GATE ENGINEER I DATE I FA. FORE.PE. 1 0405-13 F.A. FORE,P.E. 0413-13 C CAGE CODE DwG Na L13EN0028 cA0 FaE NAA'E Jvfq-xx-96esm I REVISION N/C IWAM N/A 4 3T i 2 C —1 B A i I i 4�3 y 2 1 1 i xewsara , c�rrvoe Bn oEsommw are AAmoven EE DETAIL !IL TOWER TOWER I, TOWER TOWER A~ TOWER FACE I 3 I EE DETAIL B 7 SCALE OA32 D O 12 456 A I G e f e l r o czi DETAIL 0 OR PO A SCALE 0.126 TWRD ANGLE PROJECTION f77 US HWY ONE CONNECT -IT WIRELESS, INC � M.33�9 TEOIJEAWLYSES A SOLUM USA I6611 74+MO ', VF13-Xx-96 ENGINEER DATE FRANKAfd1REW FORE, RE DATE 13' V•FRAME BOOM GATE DE9CN ENSugR F.A. FORE P.E 04-05•13 wwEB mv.RACr anwAREo MUCTURES EMM: F.A. FORE,P.E 0413-13 yg CAGE CODE: DWG NR DRAFTSMAN 42561 C I L13ENG028 FUWASHEB'IMER APPFIDVFB BY: VG N0. SEAL COMACT I JOB NO, 13EN0028 CAD FU N , Jvfl3- -96a SHEET. 2 of 13 R r* WC SCALE VARIOUS 4 III {.1 3 T 2 1 1 V I I I I 0 C B A 4 3 2 1 1¢N90n15 nuwe ua ova>Tv++ ogre �rn+ovm TOWER D V D n � s L i 000e i , n o 7 c e c I t1 - s F G - 12 12 Ii 0 E 0 a I I � 9 � F+J smi S AL'E ON A -A DETAn. B 02 SCALE Q375 DTYP 2 PU i,T�ilD ANGLE PROJECTION r" u °NE BATE -3W CONNECT -IT WIRELESS, INC A FRANK APMREW FORE. PE DATE ANLLYffS 8 SOLUfpHS TEOUEVA, FL 33469 USA 1561 744-OS A VF13-xx-96 13' V-FRAME BOOM GATE EMNEER WMN a>Gume F.A. FORE,P.E 04-05-13 42561 UC. N0. SEAL tPW CONTRACT Um CmmCT PREPARED SIMCTiREi SWUM F.A. FOREPE. 04-013 5� C CAGE CODE DWG Na L13ENG028 °i�f5°'"'� FlRMSED � By: • Joe Na 13ENGMB CAD RE Wr4 lvfY3•nn96.e� 3 of 13 T1EY60N WC scat!= VARIdIS 4 it 3 2 1 4 3 2 7 FE Woa wwoe rn tzorbkml wre ervaovm D i ❑ I TOWFA TOWER 4 I 4 6 I n s � 5 c 4 C Iz a a I a 4 4 4 4 a 4 SECTION 7 SCALE 050000 RTP 4 PLI 7 SECTION DD SECTION E4: I SCALE OEOO SCALE 0500 I 'T°R° ANGLE PROJECTION m�+G CONNECT -IT WIRELESS, INC TEOUESTA,.FL 334GG ANu-YffSE6aLU07K USA ISSA 744A510 o ^ VF13-xx-96 A •, ENGINEER DATE FRAM( AI�REW FORE. P.E DATE 13' V-FRAME BOOM GATE A Dam �ra� FA. FORE,P.E. 04-05-13 UNDM CWIRACT PIUMED STRUCTUIIE9 HTHER F.A FOREPE 04-13-13 s CAGE CODE DWG Na.. °"�uvw 42561 C L13ENG028 'FlIiALL9iFD AF4ROVED BY: LTC. ND SEAL LL�i CENLRACi im xa W6028 Den 4 of A fmv�gn N/C ISCALE VARIOUS 4 I I 3 T 2 1 4 0 THS FACE CAN POLAR OUT OR IN C 9 A FRANK AImREW FORE PE GATE 42561 LIC Na SEAL 4 AL 0 OR O SCALE 0.100 D ANGLE PROJECTION D 3 .E7 THS FACE CAN POINT OIIT CR IN 2 SECTION FF SCALE OE00 (TYP 9 PLI a Lo C 9 SECTION 0-0 SCALE 0.500 RYP 2 PU "' 06 HINTONECONNECT-IT WIRELESS, INC TEOTA, L 156 7 33469 USA IS6A 44-0510 GATE VF13-xx-96 P.E. 04-05-13 13' V-FRAME BOOM GATE A PE 04-13.13 E CAGE CODE 0WG NP. C L13ENGO28 Dili AR- STET. 5 of 13 IRVIISM we la .. VARIOUS 2 4 3 2 + nevoia�a uunte en orE � oesmrnm tare AwBovm D t6 i LS IS 15 is D d 1 19 19 19 19 + I c 13 c 14 14 36.000 I 9 I' 13 19 19 19 i9 E E oErAO ID TFrRD ANGLE PROJECTIONqp 1n SUM us Hff3M CONNECT -IT WIRELESS, INC A 64�ENGNEERORr:, MESTA, FL 33469 �$ 6 Ng USA F6Q 744.010 A -96 VF13 XXANK DATE OWSWEucirmc FA FORE,P.E oa-0s-�3 FRANDREW FORE PE LATE 13" V-FRAME BOOMIU7 GATE UMM wvnucr PREPAFM STM)M s Eua'fm FA FORE.PE. 0413.13 97E CAGE CODE Dwo NO: 42%1c- C L13ENG028 AMOM . LIC. N0. SEAL UMM CBN ,= i JDB Na 13ENG028 cm fa.E NAME Jvf13-X%-96� MUM N/C 1vei F 0500/1 4 I 3 2 1 4 13 2 1 I ' I I ouxoe xa ¢vma �so+�nw ogre Iasuavm D I , 1 0 I6 i6 16 16 I I I6 I 2O 20 20 20 20 D I. I D 13 4 mom I 4 J J .. •• H B 13 I.20 I 20 • 20 20 20 g mra 0 ANGLE FRaEcnoN r"� M CONNECT -IT WIRELESS, INC TE00ESTA, FL 33469 ANOI E 9]AIIOS USA 740DATE VF13-xx-96 ENGINEER A FRANK AIMREW FORE, PE DAiE 13" V-FRAME BOOM GATE A DmGm INGNm FA FORE,P.E 04-05-13 lrmrn CaBmACT PWAHM sTwMullis FriBufm: FA FORE,P.E 04-1313 � CAGE COOS DWG N0: �MN 42561 1 c L13ENG028 I FVIB+s1m AMOVE0 BY: LIE. N0. SEAL Omm rarmncr JOB BO 13MG028 CO RE r Jvfl3-la-96asn SHEEI: 7 of 13 BEMM WC IXALr 0,094/1 4 l 3 T 2 4 bT C B A FRANK AM31EW FORE PE DATE 42561 LIC. NO. SEAL 4 3 MASTS 3MA MASTS ANGLE PROJECTION \17 / •_•• AN omm EJGPgR 9 IRDQt CWIMCT SIRLCTIDES EIGI DRAFTSIAR fD CWCONTRACT APMVEO By: I. d® N¢ L'IE 3 2 1 1 C 5 ANTENNA MASTS is NOTE L 3, 4, OR 5 MASTS ARE THE ONLY ALLDWABLE CONFIGURATIONS 2 MLY THE CONFIGURATIONS SHOWN ARE AU.OWABLE 3 MASTS MUST BE SPACED AS %MM 4. IT IS PERMISIBLE TO MX MAST PPE CIAMETERS, BUT NOT LENGTHS f77 US HWY ONE �0�S 69 CONNECT -IT WIRELESS, INC USA 150 744-0510 ENGINEER I DATE VF13-XX-96 FA FORE,PE 04.05-13 13' V-FRAME BOOM GATE A FA FORE PE 04-13.13 52E CAGE CODE DWG Na c I L13EN0028 C40 RE NAAE ./03xzASesm SIffT: 8 of 13 REMS09 WC JWALr Q048/1 2 1 1 4 G C G A FNANK ANOREW FORE, PE OAIE 42561 Ea -No. SEAL 4 SECTION H-H SCALE 0500 ' IT1P 4 PL1 ANGLE PROJECTION 3 3 2 SECTION " SCALE 0.600 0TP 10 PLI u 7 C G rn 06 H 01� CONNECT -IT WIRELESS, INC ms 9J TE 3f0 MPLYg58 51U0@S TEGUE6TA, FL 33469 GSA ISM 744-WO ENGINEER GATE VF13-xx-96 A fm FA FORE.P.E 04-05-13 13' V-FRAME BOOM GATE FN0Um FA FORE.PE 0413.13 CAGE COGS OWG Na. Si7E r: C L13ENG028 1300028 CAD FU � ./vfllm-S6= RRVI a* N/C VARIOUS 2 1 4 7 c 6 SECTION K-K SCALE 0500 W 2 PLI A FRANK ANDREW FOSS, PE DATE 42561 EF-R-a SEAL ANGLE PROJECTION / EE]• 3 2 DETAIL L SECTION R4M SCALE 0500 SCALE OSDO TIYP 2 PLI RYP 2 PU MaEalm m D6 HWY ov9 - SITE3L CONNECT -IT WIRELESS, INC 33469 MW.YffS 6 Sd.IfTIWI.S_ TEOUF M M.OM USA 1560 744.OSNI ENGINEER I DATE VF13-XX-96 DMON FTC F.A. FORE.PE. 04-05-13 13' V-FRAME BOOM GATE STRUCTURES MMM FA FORE,PE. 04-1343 g2E CAGE CODE I DWG NO. AFMM ,: C L13ENG028 Jog N¢ MENG029 role /VfG-U-96a SRE1iT: f0 of 13 REVL90k WC SCALE VARIOU 3 2 1 1 0 c D A i 4 3 2 I rsn�a GwnE N4 K oEStmvaal wre armovm D 1 I D I C C 9 g __—_—_____—_—_—_______—_—_—_—_—_____—_ — a=aFU —L 10 ------------------------------------- 61 I O O I DETAJL( SCALE 0250 7HIRD ANGLE PROJECTION "9 SUITE �3q CONNECT -IT WIRELESS, INC A ///mil I \ mys s 8 6LLUIIGVS 7EOIIEGTA, FL 33469 GSA (561) 74+0510 VF13-xxOO 6TFOREA GATE FRANK AWREw FORE, P.E. OATS \W/ 13" V-FRAME BOOM GATE A �� �� F.A. FORE,P.E 04-05-13 MM tMM CONTUaT Fli SR=FIES EN6MM F.A. FOREPE 04-i3-i3 S� CAGE CODE DwG NO. DRA�S� 4256, c L13ENG028 A� �: cFei Jai NM 13MG028 CAD FE NAME /vfl3•u.g6,asm am if d f3 mmsm N/C SCALE VARIOUS 4 I 3 T 2 1 4 3 2 1 a@ ssaru CYfiIE N2 1 OAIE IIHAOVFD 3.500 -+I D D 0.813 4250 5.000 Oz375 33.000 I' _—_—_______—_—_—_____—_____—_______ no DETAIL 10 1 R4.750 SCALE 0250 375 —� I O C C TI SCALE LE 0.375 18.000 I0.500 275 I ¢ bl3 I LSao 13.000 �- 2 0 r3000 y 063 -tjj- B 9 RS63 LJLI 3.000 0.688 250 I� 14 PLI 3A00 2S0 0563 i OETAILO 16000 SCALE 0.375 I' DETAIL II SALE 0375 THRD ANGLE PROJECTION 177 t HWY ONE " CONNECT -IT WIRELESS, INC TEG �„� A01-'3:5 51L6 USA 15611 744-MM ENGINEERDATE A A cesGN EM,umt FA FOREORE. E. 04-05.13 FAAM1IX At�REW FORE, PE DATE 13' V-F AME BOOM GATE MM� UM C tAU S1u'C M aaGmme FA FOREP.E 041313 ScM CAGE COOS DWO NO, 4561 C L13ENG028 � FUWMlM Irmal CONDIACi APPROM"L APPROVE] BY. LIC N0. SEAL 1 Joe N¢ 13EY40028 CAD FiE NAME J43-m-K2 n SHEET: 12 of 13 Immax N/C IMAM VAFUGIIS 4I 3 2 1 4 I 3 2 i nrvman aw�os nn acsawnax u�re �avm 156.GDo 25209 fo5583 t500 12 PLI I t-L 0563 u PLI 0.688 12 PLI I DETAIL N Pub— 0� �--- M3,5 I ► uP� o4,1 1, + A. A. I 34.)00 (2 Pt! (Z' Ll' SCALEE QU ai25 3250 Lszs - ---- - ED t000 563 6z000 DETAIL N SCALE 0250 I ITYP 5 PLI J t25p i I 49.50° I250 aoo0 L 67EF1 mfi 4:� ao9° I_ I, z00000 I(_ 0563 {--�{z0oo a PLIS ON� ® DETAIL SCALE SCALE 0.188 TWO ANGLEPp°'E°n°" m� 3 ME WIRELESS, INC A � 6 SVJmo1s TEOUEUX FL 33469 USA MI) A VF13-XX-96 ENGIENGINEER�, °EM � F.A. FOREP.E 0405-13 FRAM( ANDREW PORE• P.E. DATE 13" V-FRAME BOOM GATE P,AMV MM CMMa SIRUCNIRES ENWMt F.A. FOREP.E 0413.13 � CAGE CODE DWG Na I DRAB 42561 C L13ENG028 FLVMm ttmm cofmAcf APPRo BY: LIC. Na SEAL J08 BR 13ENS028 CAD FU NAf.E ./vfl3sa•96asm En 13 of 13 11EY198N WC ISCALr VAt0011S 4 I I 3 T 2 1 Kimley>>> Horn Carrier Designation: MetroPCS 700 MHz Upgrade Carrier Site Number: A2P0309M Carrier Site Name: GTP HWY 70 Site Data: 2000 Okeechobee Road, Fort Pierce, FL 34945 St. Lucie County dates: 150 I. Values are v.1.1 dosign a-amcand gust � Wind speeds in miles per hour (,Is) at 33 ft (IM above ground for Eapusmvn C cab egmry. 2. Ilnoar interpolation botwaen contours is permitted. 3. Islands end coastal areas outside the last contour shall Use the last bind speed contour of the coastal area. 4. Mountainous termia, garges, me" praeantmAes, and special wind reeions shall be e%aeined for uhusaal wind condi- tions. 5. wind speeds correspond to approxiewt.ly i a 79 probability of meedaace In 50 years (Annual Ezceedance Probability a 0.00143. MUI a 7Be years). Vnominal — Vultimate X 0.6 151 mph x 0.6 = 117 mph 2014 Florida Building Code — Figure 1609A 1920 Wekwa Wdy, Suite 200;': West Palm Beach % 113,3411 RECEI'.'-D SEP 14.2015 J g+T GRP September 4, 2015 Luke Price �� BY E� B+T Group SBA Communications Corporation 1717 S. Boulder, Suite 300 9900 WestPoint Drive, Suite 116 St. Lucie County Tulsa, OK 74119 Indianapolis, IN 46256 (918) 587-4630 (205) 908-5792 btwo@btgrp.com Subject: Structural Analysis Report T-Mobile Designation: Site Number: A2P0309M Site Name: A2P0309M SBA Communications Corporation Designation: Site Number: FL17050-A Site Name: TC SR-70 Application Number: 22456, v2 Engineering Firm Designation: B+T Group Project Number: 100926.001.01 Site Data: 24880 Okeechobee Road, Ft. Pierce, St. Lucie County, FL 34945 Latitude 27' 22' 35.72", Longitude -80° 35' 16.13" 250 Foot - Self Support Tower Dear Luke Price, g+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: Existing + Reserved + Proposed Equipment Note: See Table 1 and Table 2 for the proposed and ebsbng loading respectively. Sufficient Capacity Tower: 69.2% Foundation: 47.0% This analysis has been performed in accordance with the 2014 Florida Building Code 5th Edition based upon an ultimate 3-second gust wind speed of 151 mph converted to a nominal 3-second gust wind speed of 117 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. All equipment proposed in this report shall be installed in accordance with the attached -drawings for the determined available structural capacity to be effective. - e a +T Group -appreciate- the opportunityof providing our continuing professional services to you and SBA Communications Corporation. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: B+T Engineering, Inc. Brandon Sevier, E.I. Project Engineer tnxTower Report - version 6.1.4.1 John W. Kelly, P.E., S.E. Engineer of Record COA:27496 Expires:2/28/2017 ``.� off.: -•.....( ��%; a. 6 4 - %�o,� �•. ( �0@:-� to .� rrmm�utu�"'� "It 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 — Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations September 4, 2015 Site No. FL17050-A Page 2 tnxTower Report - version 6.1.4.1 t v 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL 1) INTRODUCTION September4, 2015 Site No. FL17050-A Page 3 This tower is a 250 ft. Self -Support tower designed by Central Tower, Inc. in September of 2003. The tower was originally designed for a wind speed of 120 mph per TIA/EIA-222-F. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 117 mph with no ice and 60 mph under service loads, exposure category C with topographic category 1 and crest height of 0 feet. Table 1 - Final T-Mobile Loading Antenna and Cable Information Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (In) Note 3 Andrew DBXNH-65658-A2M 3 1.24 T-Mobile Proposed 6 Cellmax Tech. CMA-BDHH/6520/EO-8 3 Nokia FRIE 248.0 248.0 6 15/8 T-Mobile Existing 3 Nokia FRIG 3 Nokia FXFB 3 Raycap ASU9338TYP0I 3 Sector Mount Table 2 - Existing Antenna and Cable Information Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed' Line Size (in) Note T-Mobile 3 Cellmax Tech. CMA-BDHH/6520/EO-8 3 1.584 To Be Removed 6 Cellmax Tech. CMA-BDHH/6520/EO-8 248.0 248.0 3 Nokia FRIE 3 Nokia FRIG - - 6 15/8 - T-Mobile Existing 3 - `Nokia ---FXFB - Raycap —ASU9338T-YRG:1 -- - -- - - - ccrorivroan-- -- -- - tnxTower Report - version 6.1.4.1 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL Table 3 - Design Antenna and Cable Information September 4, 2015 Site No. FL17050-A Page 4 Mounting Center '. Line Number Antenna Number Feed . of Antenna Model of Feed Line Level (ft) Elevation Manufacturer Antennas • Lines Size (in) 12 Decibel DB982F105E-M 250 2,90 12 1-5/8 1 Generic 13' Gate Mounts/T-Arms 9 Decibel DB982F105E-M 225 225 g 1-5/8 1 Generic 13' Gate Mounts/T-Arms 9 Decibel DB982F105E-M 220 220 g 15/8 1 Generic 13' Gate Mounts/T-Arms 150 150 2 Generic HP6-S7W 1 2 1 7/8 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document Remarks Reference Source Tower Data Tower Drawing by Central Tower Inc., Project No. SS1366 Date:09/1012003 SBA Foundation Data Foundation Drawing by Central Tower Inc., Project No. SS1366 Date:09/1012003 SBA Soil Properties Morrison Hershfield, Date:08/0112003 SBA Existing Loading SBA Site Summary Form, Site Id: FL17050-A Date:06/23/2015 SBA Proposed Loading T-Mobile Application# 22456, v2 Date:09/02/2015 SBA 3.1) Analysis Method tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. -3) The configuration of antennas, transmission cables, mounts and other appurtenances are as Bolt details were not provic by the same manufacturer. were on similar towers This analysis may be affected if any assumptions are not valid or have been made in error. B+T Group should be notified to determine the effect on the structural integrity of the tower. tnxTower Report - version 6.1.4.1 250 Ft Self Support Tower Structural Analysis Report Project Number 100926.001.01, TC SR-70, FL 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) September4, 2015 Site No, FL17050-A Page 5 Section No, - - - Elevation (ft)' e Compoheiit Type Size Critical Element P (� S'.; SF`P-allow CK) Capacity Pass /Fail T1 250-240 Leg 2114 1 -21.391 130.399 16.4 Pass T2 240 - 220 Leg 21 /2 28 -82.625 167.374 49.4 Pass T3 220 - 200 Leg 3112 73 -106.954 256.230 41.7 Pass T4 200 - 180 Leg 4 94 -135.211 378.448 35.7 Pass T5 180 - 160 Leg 4114 115 -163.640 447.281 36.6 Pass T6 160 - 140 Leg 4112 136 -193.191 521,096 37.1 Pass T7 140 - 120 Leg 4 314 157 -224.217 599.797 37.4 Pass T8 120 - 100 Leg 4 314 178 -257.162 599.797 42.9 Pass T9 100 - 80 Leg 5 199 -292.242 683.313 42.8 Pass T10 80 - 60 Leg 51/4 220 -329.438 771.566 42.7 Pass T11 60 - 40 Leg 5112 241 -369.358 864.519 42.7 Pass T12 40 - 20 Leg 5 314 262 -411.623 962.128 42.8 42.8 (b) Pass T13 20 - 0 Leg 5 3/4 283 -455.600 962.128 47.4 Pass T1 250 - 240 Diagonal 1 15 -4.228 13.997 30.2 Pass T2 240-220 Diagonal 11/8 42 -5.769 18.668 30.9 Pass T3 220-200 Diagonal L2x2xl/4 92 -4.569 15.422 29.6 37.9 (b) Pass T4 200-180 Diagonal 1_21/2x2112x3/16 101 -4.381 14.728 29.7 42.4 (b) Pass T5 180-160 Diagonal L21/2x21/2x1/4 122 -5.121 15.499 33.0 37.2 (b) Pass T6 160-140 Diagonal L21/241/2x5/16 143 -6.003 14.284 42.0 Pass T7 140- 120 Diagonal L3x3xl/4 164 -7.172 16.000 44.8 47.7 (b) Pass T8 120- 100 Diagonal L3x3x3/8 185 -8.340 18.227 45.8 Pass T9 100-80 Diagonal L31/2x31/2x5/16 206 -9.765 20.218 48.3 Pass T10 80 - 60 Diagonal L4x4xl/4 227 -11.248 20.530 54.8 63.5 (b) Pass T11 60-40 Diagonal L4x4x3/8 248 -12.943 24.883 52.0 54.1 (b) Pass T12 40-20 Diagonal L5x5x5/16 269 -14.796 35.576 41.6 62.5 (b) Pass T13 - 20 - 0 -- - - Diagonal - L5x5z5/16 290 -16.429 30.474 53.9 - 69.2 (b).. Pass T1 250-240 Top Girt 1 5 -0.065 10.727 _0.6_ Pass -- - -- -- -8--1.196 T1-- 250-240 Bottom Girt 1- 10.727 11,2---Pass T2 240-220 Bottom Girt 11/8 36 -0.218 16.396 1.3 Pass Summary Leg (T2) 49.4 Pass Diagonal (T13) 69.2 Pass Top Girt (T2) 9.3 Pass Bottom Girt (T1) 11.2 Pass Bolt Checks 69.2 Pass RATING = 69.2 Pass tnxTower Report -version 6.1.4.1 t 250 Ft Self Support Tower Structural Analysis Report Project Number 100926. 001. 01, TC SR-70, FL Table 6 - Tower Component Stresses vs. Capacity September4, 2015 Site No. FL17050-A Page 6 Notes Component Elevation (ft) % Capacity Pass 1 Fail 1 Anchor Rods I Base 47.6 Pass 1,2 Base Foundation (Structure) Base 47.0 Pass 1,2 Base Foundation (Soil Interaction) Base 42.6 Pass Structure Rating.(max from all components) = 69.2% Notes: 1) See additional documentation in 'Appendix C -Additional Calculations' for calculations supporting the % capacity consumed. 2) Two foundation drawings were provided. The worst capacity was reported in this analysis. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing and proposed loads. No modifications are required at this time. tnxTower Report - version 6.1.4.1 APPENDIX A TNXTOWER OUTPUT a rc rc a oppe N r F tl N w tl h N 7 C L`4 to o a to tl 7 p � N � a d e C ON g C N N '3 250 0 It 240_a It 220_0 n 2000It DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION Lightning Rod W x 4' on 6 PnIe(E) 255 FRIE(E) 248 Strobe(E) 251 FRIE(E) 248 (2)CMA-SOM652 0/ 8w/Mount Pipe (E) 248 ABu9338 l(E) 248 ASU9MIP1(P01(E) 248 wl Mount p (2)CMA-BDHHIfi5 CGM w/Mount Pipe (E) 2" 248 Y)cMA-BD*1I65IIM0a Asugmaol(E) 248 DBXNHE585&A2M wI Maunt Pipe (P) 24fl DB%NH-fi5658-A2M w/Mourd Pipe (p) 248 F%FB (E) 248 F%FB(E) 248 DEIMI-1 65BA2M w/Mount Pipe (P) 248 F%FB(E) 248 FRIG (EI 248 Setl Mount ISM IW0 3] (E) 248 FRIG (E) 1248 Side Ugh" (E) 125.5 FRIG (E) INS Sid. ❑gh8ng (E) 125.5 PRIE (E) 248 ISIde LlghBng(E) 125.5 SYMBOL LIST 1ee.ort1 MARK 1 SIZE 1 MARK SIZE A 13 ®3.08333 / MATERIAL STRENGTH GRADE Fy Fu 1 GRADE I Fy Fu 180.0 fl A512-50 50 w 651¢I 1A 6 jstik t Iss W TOWER DESIGN NOTES 1. Tower is located in Saint Lucie County, Florida. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 117 mph basic wind in accordance with the TIA-222-G Standard. 1400 It 4. Deflections are based upon a 60 mph wind. 5. Tower Structure Class I. 6. Topographic Category 1 with Crest Height of 0,000 ft 7. TOWER RATING: 69.2% 120.0 n 1000n 8aon 60.0 n ALL REAC7ONS ARE FACTORED MAX. CORNER REACTIONS AT BASE ao.an DOWN: 463K - - - - - - - SHEAR: 47 K UPLIFT' 375 K - __ _ _ __ SHEAR: 39K z5.0n AXIAL — - - — 93I K SHEAR MOMENT 79 K / J. 9347 kip-R O.01 TORQUE 51 klp-R REACTIONS- 117 mph WIND B+T Group 1717 S Boulder Ave, Suite 300 B-T GF:P Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 m: 100926.001.01. TC SR-70, FL Site# FL17050-A)_ Prgact Cnene SBA Communications Comomfo Dnnen"' B. Sevie Apptl. Coda' TIA-222-G D3nu 09/04/15 son"; NTS Pao: m,w.cee.mg o,xvx a. Dwg li, E-1 Plot Plan Total Area - 0.07 Acres A \ 1 \ -.� Base eer-0.000fl 12500 12500 15.000 25000 15.000 55.000 B+T Group 1717 S Boulder Ave, Suite 300 e+r �«xr Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 a": 100926.001.01 - TIC SR-70, FL Site# FL17050-A aroiex am"e SBA Communications Co omfi 0ra'""�y B. So pd; CaO: TIA-222-G oam:09/04/15 Scale MS Pafl1° .1 ms—a Nn— TIA-222-G -117 mph Exposure C Leg Capacity Leg Compression (F) 15W 1000 5W Mlnlmum-0 Maximum -500 -1000 -1500 250.00 50.000 I I I I I I I I 1 I I I I I I I I I I I 11 1 1 I I I I 240 I I I 1 I I I I I 1 i , 1 1 1 1 1 I I 40.000 1 I 11 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 I 1 1 11 1 i I I I I 1 1 1 1 I 1 I I I I I I 1 I 1 I I 1 1 r I 1 1 1 1 1 1 1 220.00 I 1 I 1 1 I 1 1 1 I I 1 1 I 1 1 °.000 I 1 1 1 1 I I 1 1 I I 1 1 1 I I 1 1 1 1 1 1 I 1 1 1 I I I I 1 1 1 1 1 1 1 I I 1 1 1 1 1 I I I 1 1 1 1 1 1 1 I 1 1 I 1 1 1 1 1 1 200.0 _J _L_J _L _L _J _1 _♦_ 1 1 _L _L � L_J _L_J _J _L_J _I 00.000 1 I I I I I I I I 1 I I I I I I I I I I I 1 I I I I I I 1 I I I I 1 1 1 I 1 I I I I I I I I I I 1 1 I I I I I I I I I I I I I I 1 I I I I I I 1 160. I I I I I I 1 1 11 I I 1 I_ -I- 80.000 I I I I I 11 I 1 I I I I 1 1 I I I I I I I I I I I I 1 1 I I I I I I I I I 1 I 1 I I 11 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I 160.0 I I I I I I I I I 1 1 I I I 1 1 I I I fio.OW 1 1 i I I I 11 1 1 1 I I I i 1 i i i I I I I I 1 I I i i 1 1 i 1 1 I 1 I I I I I I 1 1 1 1 1 I I 1 1 I I I I I 1 1 1 I I I I 1 1 1 1 i I I I 1 I 1a°.o _J__I__J__I__ __I__� I__!____!_!__L_ i__ _!__ _JL_ I 40.000 � 1 1 1 1 1 1 1 1 r 1 1 1 1 p p I I 1 I 1 1 1 I I 1 I 1 I 1 1 I I I I 120.00 _ _ _ _ ~ 120.000 I I I I 1 I 1 I I I I I I I I I I I I I I I i I W I I I I I I I I I I I I 1 I 1 I I I I I I I I I I I I I I I I I I I I I I 1 1 100.00 I I I 1 1 1 I I I I I i I I I I I 1 1 1 00.060 _�__r_i__r_ __r_ __1__.,____r__I_ r__1__ __I__r_�__r_ __r____ __ _�__r _�__r_ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 I 1 1 1 1 1 I 1 1 1 I I I I 1 I I I I 1 1 1 11 1 1 1 1 1 I r l 60. 1 1 I 1 I I I 1 1 1 I I a.°o0 I I I 11 1 1 1 I i I I I I I 1 1 1 1 1 1 I 1 t I 1 I I 1 I I I I 1 1 l i l l 1 1 I I 1 1 I I I I 1 1 1 I I I I I i I 1 1 1 1 I 1 I I I I I 1 1 1 I I 1 1 I I I I I I I 1 I I I I 1 1 1 I I I 1 I 60. a ------- _L---- L_�______ I I I I 1 I 1 i I I I I 1 1 I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I 11 I 1 I I 1 _ O° _ I 1_ 1 1 1 1_ I I 10 fi I I I I I I I I I I 11 I 1� I I I I I I I 11 I I I I I I I I I 1 I I I 1 I I I I I I I I I I I I I I I I I I I 1 I I I I I 1 20.00 I I1 I I 1 IIII � I 1 0fi°0 _ _.I _ _I _II _ _II _ _II_ _ _ _I _ 1 11 1 I I I I I I 11 1 I 11 I 1 1 11 I I I I I 1 I 1 1 I 1 I 11 I I I I I I 11 1 I I I I I I I I 1 I I I I I I I I I 1 I I I I I I I I I I I I I I 11 1 1 I 11 I I I I 1 1 1 1 I 1 1 0. OW 15133 1000 5W Mlnlmum -0Maxlmum-+ -SW -iW0 -15W B+T Group 1717 S Boulder Ave, Suite 300 a.T GRP Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 J.b. 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Pmlec Glen SBA CommunicationsCorporatio °mini°>'B. Seme App°; ° 01 TIA-222-G °ar8 09/04/15 sum. NTS aam: 0,w Na.E-3 TIA-222-G - 117 mph Exposure C Maximum Values Vx----------- -Vz Mx ------------ Mz Global Mast Shear (K) Global Mast Moment (kip-ft) I I 24000 � 1 1 I I 1 1 1 I I I 1 I I 1 I 1 1 1 I 1 I 1 I 1 I I I I 1 zW.40 I 1 I 1 I I I 1 I I 1 I 1 1 I I I I 1 160.00 I I I I I I I 1 I I 1 1 I 1 I 1 i I 1 1 I I 1 I I 1fi0.00 1 I I I I I I 1 I I I ;I 140.06 1r I I I� I I I 1 I I O 1 I• 1 I 0 1 f0 120.00 I 1 I 41 W I I I y I I I �.� I I I I I I I I I I I I I I I i I � I I I I I I I I I I I I I I I I I I I i I I I I 1 I I I I I I I I 1 1 I I I I I I I I 1 I 1 I 1 1 1 1 I I I 1 I 1 � 1 I I I I I I I I I 1 1 1 I I I I I I I 1 1 I 1 1 1 I 1 1 I � I I 1 1 1 1 1 1 1 I 1 I 1 I 1 1 1 1 I 1 1 1 1 I I ' I I 1 4 1 } 1 I I 1 I i ' t 1 I i I � 1 I I 1 1 1 I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 I 1 1 I I I I I I I I I 1 I 1 � � I 1 I � I 1 1 I I I I 1 I I I I I I I I 1 I �I I I I I I 1 \ f� I I` 1 I 1 I) 1 I I I I \1 I I I I I 1 I I 1 I I I I I L t I I i 1 1 I I I 1 I I I 1 I 1 1 1 1 I 1 1 1 I I I I 1 1 � I I 1 I I I 1 I I I I I I I I I I I I I I 1 I i I I I I I I I I 1 � I I 1 I I 1 I I I 1 i 1 I I I 1 I I I I I I I I I I I I I 1 I 1 I I I I I I 1 1 I I 1 i 1 1 1 I 1 r 1 1 I i I 1 I I 1 I I I I 1 E I I \ I I 1 I �- B+T Group 1717 S Boulder Ave, Suite 300 B+T GHP Tulsa, OK 7 Phone: (918)587-4630 FAX: 918 295-0265 ab1100926.001.01 - TC SR-70, FL Site# FL17050-A PmIec cuenc SBA Communications Corporado o`a'"nbv'B. Sevle APWd° code: TIA-222-G oam: 09/04115 scald: NTS Palb: 2 e 1 E-4 TIA-222-G - Service - 60 mph Maximum Values Deflection (in) Tilt (deg) Twist (deg) a 5 a 0.05 0.1 0.15 a 0.05 0.1 zsoa o.mo 1 I I 40W y 1 1 I I I 11 1 I I I 1 I j I I I T r I I I I I 1 IT I UOM 1 I 1 1 I T_____I__ __r____T____ 1 1 I I 1 1 I 1 1 1 1 ____________________ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I zao.ao 1 I I I I I I IIIIIII IIIIII IIIIII I I I I _LIIIIIII _JIIIIII I I I I I I I I _FLIIIIIII I I I I 180. _____,iII1i __ILIIIIIII __JIIIII -_}_k__A__ _. _ __I_4} oo 00 6e000..ma --- ,-- - --r -_--- -r I I -r--T-r---I- I I I I I I I I i-r-I- I I I I -I-- I I I I --r-7--T--r- I I I I 14000 ' I I I I 1 1 i I I I I I I I I I I I I I I 40M I I 1 I I I I I I I I I I I I I I I I ! I I I I C I I I I 120. �_J_1_L 20.o0o ? -____y_____�____.____ _�_i_1_I___J_1_L_I_ _! _1__L_J__ __I__!__!__I__ W I I I I I I I I I I I I I I I I I I I I I I I I I I I IW.W i i i i I I I I I I I I I I I I I I I I I I I I 1 I I 1 I I 1 I I I I I I I I I I I I I I I I I I I e0.00 I I I I i 1 I 1 I 1 1 I i 1 I I I I I I I I i I I I I I I I I I I I i I I I I I I I I I I I I I i I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I 0ooa sa.aa 1 I i i I I I I I I I I I I I I a.aoo ---4----------`----`---- 1 1 I I -r7 T-r--7--1-r-r--7-r-r-I- ---T--r-�-- --r----T--r- I - 1 I I _ 1 I I l r--I -- z0.0 1 1 I i I I 1 I 1 I I I 1 I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0.aoa B+T Group 1717 S Boulder Ave, Suite 300 s.r�Rp Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 ab:100926.001.01- TC SR-70, FL Site# FL17050-A Pf J.a - C°enO SSA CommunlcaBons Corporatio O1H1'" by e. Sevle^I" Ca6a: TIA-222-G Dale: 09/04/15 smI°` NTS Pap''111.11111. —, w1 °I r1.—, a �. E5 B+T Group 1717 S Boulder Ave, Suite 300 BK GLP Tulsa, OK 74119 Phone: (918) 587-0fi30 FAX: 918 2950265 lob: 100926.001.01- TC SR-70, FL Site# FL17050-A Pf* B SBA Communlcabons Conoomflo Dm nbp B. Sevie ^P°^ Ca°B' TIA-222-G 081 :09104115 Stale: NTS Pa°' D�N.. E-6 1 Feed Line Distribution Chart 0' - 250' Round Flat App In Face . , . - . App ON Face buss Leg 250.000 Face A 248.a00 Face B Face C 250.000 248.000 240.000 _ _ _ 240.000 22a_000 _ _ _ 220.000 2o0.ma _________________________ ___________n ________ ___ 200.000 U 160_000 980.000 ____________ ________ ___ 160.000 _ _ _ 160.000 140.000 140.000 C a m 0 m _______o _ _ _ 1255W _________________________ 125500 ___ ________ ______ - ___ 120_000 0 120.0na W 100_000 _ _ _ 100.000 eo.000 ___ ________ ________ ___ _________________________ __,- _________________ ___ e0_1M V m fia.000 60.000 a E ao.000 -- __. _ _ _ _ _ _ _ _ _ _ _ - 40.000 - Z0.000 20.000 B+T Group ,r 1717 S Boulder Ave, Suite 300 Tulsa, OK 74119 Phone: (918) 5874630 FAX' 918 295-0265 ab: 100926.001.01 - TC SR-70, FL Site# FL17050-A pmlaR Glen" SBA Communications Corpora8o D'a"'" by B. Sevia App'a: Co°e' TIA-222-G DB1e: 09/04/15 spele. MS pa": ae,e.,x,.v.,w.n a„on. asr. . OwO tI.E-7 tnxTower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page1 of 26 Project Date 08.51:59 09/04/15 B+T Group 1717 SBoulder Ave, Suile 300 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 FAX..- (918) 295-0265 SBA Communications Corporation B. Sevier Tower Input Data The main tower is a 3x free standing tower with an overall height of 250.000 ft above the ground line. The base of the tower is set at an elevation of 0.000 ft above the ground line. The face width of the tower is 4.000 ft at the top and 25.000 ft at the base. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Saint Lucie County, Florida. Basic wind speed of 117 mph. Structure Class R. Exposure Category C. Topographic Category 1. Crest Height 0.000 ft. Deflections calculated using a wind speed of 60 mph. A non -linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in tower member design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC.6D+W-Combination — -- Options Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For KLJr Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area ofAppurt. Autocalc Torque Am Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Use TIA-222-G Tension Splice Capacity Treat Feedline Bundles As Cylinder Use ASCE 10 X-Bmce Ly Rules 4 Calculate Redundant Bracing Forces Ignore Redundant Members in PEA J SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation 4 Consider Feedline Torque J Include Angle Block Shear Check Poles Include Shear-Torsiou Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets MxTowei Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 2 of 26 Project Date B+T Group 1717SBoulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAY: (918) 295-0265 Wind 180 1 Lea A Wind 90 Lem 2Leg B Face C Wind Normal Triangular Tower Tower Section,lGeometry Tower Tower Assembly Description Section Number Section Section Elevation Database Width of Length Sections Tl n 250.000-240.000 n 4.000 1 A 10.000 T2 240.000-220.000 4.000 1 20.000 T3 220.000-200.000 4.000 1 20.000 T4 200.000-180.000 5.910 I 20.000 TS 180.000-160.000 7.820 1 20.000 T6 160.000-140.000 9.730 I 20.000 T7 140.000-120.000 11.640 1 20.000 T8 _ 120.000-100.000 _ _ _ 13.550 _.1- _ 20.000. T9 100.000-80.000 15.460 1 20.000 --T13-- - 20.000-0.000- 23.090 I 20.000 Tower Section Geometry cont'd Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End ft ft Panels in in TI 250.000-240.000 3.083 X Brace No No 4.500 4.500 T2 240.000-220.000 3.208 X Brace No No 4.500 4.500 T3 220.000-200.000 6.167 X Brace No No 9.000 9.000 T4 200.000-180.000 6.167 X Brace No No 9.000 9.000 t=Tower Jab 100926.001.01 - TC SR-70, FL (Site# FL17O5O-A) Page3 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX' (918) 295-0165 Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt Section Elevation Spacing Type KBrace Horizontals Offset Offset End T5 180.000-160.000 6.167 X Brace No No 9.000 9.000 T6 160.000-140.000 6.167 XBrace No No 9.000 9.000 T7 140.000-120.000 6.167 X Brace No No 9.000 9.000 T8 120.000-100.000 6.167 XBrace No No 9.000 9.000 T9 100.000-80.000 6.167 X Brace No No 9.000 9.000 T10 80.000-60.000 6.167 X Brace No No 9.000 9.000 Tll 60.00040.000 6.167 XBrace No No 9.000 9.000 T12 40.000-20.000 6.167 XBrace No No 9.000 9.000 T13 20.000-0.000 6.167 XBrace No No 9.000 9.000 Tower Section Geometry cont'd Tower Leg Leg Leg Diagonal Diagonal Diagonal Elevation ft Type Size Grade Type Sine Grade TI Solid Round 21/4 A572-50 Solid Round 1 A36 250.000-240.000 (50 ksi) (36 ksi) T2 Solid Round 21/2 A572-50 Solid Round 11/8 A36 240.000-220.000 (50 ksi) (36 ksi) T3 Solid Round 3112 A572-50 Equal Angle L2x2xl/4 A36 220.000-200.000 (50 ksi) (36 ksi) T4 Solid Round 4 A572-50 Equal Angle L21/2x21/2x3/16 A36 200.000-I80.000 (50 ksi) (36 ksi) TS Solid Round 41/4 A572-50 Equal Angle L21/2x21T1xl/4 A36 180.000-160.000 (50 ksi) (36 ksi) T6 Solid Round 4W A572-50 Equal Angle L2 I/W 1/2x5/16 A36 160.000-140.000 (50 ksi) (36 ksi) T7 Solid Round 43/4 A572-SO Equal Angle L3x3xl/4 A36 140.000-120.000 (50 ksi) (36 ksi) T8 Solid Round 43/4 A572-50 Equal Angle L3x3x3/8 A36 120.000-100.000 (50 ksi) (36 ksi) T9 Solid Round 5 A572-50 Equal Angle L31/2x31/2x5/16 A36 100.000-80.000 (50 ksi) (36 ksi) TIO Solid Round 51/4 A572-50 Equal Angle L4x4xl/4 A36 80.000-60.000 (50 ksi) (36 ksi) Tll Solid Round 51/2 A572-50 Equal Angle L4x4x3/8 A36 60,000-40.000- _ (50 ksi) _ (36 ksi) _ T12 Solid Round 5 3/4 A572-50 Equal Angle L5x5x5/l6 A36 Tower Section Geometry cont'd Tower Top Girt Top Girt Top Girt Bottom Girt Bottom Girt Bottom Girt Elevation Type Size Grade Type Size Grade ft Tl Solid Round I A36 Solid Round I A36 250.000-240.000 (36 ksi) (36 ksi) T2 Solid Round 11/8 A36 Solid Round 11/8 A36 240.000-220.000 (36 ksi) (36 ksi) WxTower Job Page4 100926.001.01 - TC SR-70, FL (Site# FL17050-A) of 26 B+T Group Project Date 1717 SBoulderAve, Suite 300 08:51:59 09/04/15 Take, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Tower Section Geometry cont'd Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weighs Mull. Double Angle Double Angle Elevation Area Thickness AI Factor Stitch Bolt Stitch Bolt (perface) A, Spacing Spacing Diazonals Horizontals 250,000-240.0 (36 ksi) 00 T2 0.000 0.000 A36 I 1 1 0.000 0.000 240.000-220.0 (36 ksi) 00 T3 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 220.000-200.0 (36 ksi) 00 T4 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 200.000-180.0 (36 ksi) 00 T5 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 180.000-160.0 (36 ksi) 00 T6 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 160.000-140.0 (36 ksi) 00 T7 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 140.000-120.0 (36 ksi) 00 T8 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 120.000-100.0 (36 ksi) 00 T9 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 100.000-80.00 (36 ksi) 0 TIO 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 80.000-60.000 (36 ksi) Tll 0.000 0.000 A36 1.05 I 1.05 0.000 0.000 60.00040.000 (36 ksi) T12 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 40.000-20.000 (36 ksi) T13 0.000 0.000 A36 1.05 1 1.05 0.000 0.000 20.000-0.000 (36 ksi) --- - T-ower-Section GeomE -1 OlTt'd - - - - - - Tower Cale Cale Legs X K Single Girls Horiz. Sec. Inner Elevation K K Brace Brace Diags Hone. Brace Single Solid Diags Diags Angles Rounds K K K X K K K h Y Y Y Y Y Y Y 250.000-240.0 00 T2 NO Yes 240.000-220.0 00 T3 Yes Yes 220.000-200.0 �i`�xTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) 5 of 26 Project Date B+T Group 1717SBoulderAve, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Tower Cale Cale Legs K K Single Gins Horiz. Sec. Borer Elevation K K Brace Brace Diags Horiz. Brace Single Solid Diags Diags Angles Rounds X X X X X X X ft Y Y Y Y Y Y Y 00 ' T4 Yes Yes l 1 l 1 I 1 1 1 200.000-180.0 1 1 1 1 1 1 1 00 T5 Yes Yes 1 1 1 1 1 1 1 1 180.000-160.0 1 1 1 I 1 1 1 00 T6 Yes Yes 1 1 1 l 1 1 1 1 160.000-140.0 1 1 l I 1 1 1 00 T7 Yes Yes 1 1 1 1 1 1 1 1 140.000-120.0 1 1 1 1 1 1 1 00 T8 Yes Yes 1 1 1 1 1 l I 1 120.000-100.0 1 1 I l I I 1 00 TO Yes Yes I 1 1 l l 1 I 1 100.000-80.00 1 1 I 1 1 I 1 0 TIO Yes Yes 1 1 1 1 1 1 1 1 80.000-60.000 1 1 1 1 1 1 1 TII Yes Yes 1 1 I 1 1 1 1 1 60.000-40.000 1 1 1 1 1 l 1 T12 Yes Yes 1 1 1 1 1 I 1 1 40.000-20.000 1 1 1 l 1 1 1 T13 Yes Yes 1 1 1 1 1 1 1 1 20.000-0.000 1 1 1 1 1 1 1 'Note: Kfactars are applied to member segment lengths. K-braces without inner supporting members will have theKfactor in the out -of --plane direction applied to the overall length. Tower Section Geometry cont'd Tower Elevation n Leg Diagonal Top Girt Bottom Gin Mid Girt Long Horizontal ShortHorizontal Net Width U Net Width U Net Width U Net U Net U Net U Net U - -- - =Deduci -Deduct-- -Deduct- Width - - - -ilridlh Width - - -Width -in- ___ _ _-Deduct-edn in in in in T1 0.000 1 0.000 1 0.000 1 0.000 1 0.000 0.75 0.000 1 0.000 0.75 250.000-240.0 00 T2 0.000 1 0.000 1 0.000 1 0.000 1 0.000 0.75 0.000 1 0.000 0.75 240.000-220.0 00 73 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 220.000-200.0 00 T4 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 200.000-180.0 00 T5 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 180.000-160.0 00 MxTQwer Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) 6 of 26 B+T Group Project Date 1717 S Boulder Ave, Suite300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Tower Elevation ft Leg Diagonal Top Girt Bottom Gin Mid Girt Long Horizontal Short Horizontal Net Width U Net Width U Net Width U Net U Net U Net U Net U Deduct Deduct Deduct Width Width Width Width in in in Deduct Deduct Deduct Deduct in in in in T6 0.000 l 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 160.000-140.0 00 17 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 140.000-120.0 00 T8 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 120.000-100.0 00 T9 0.000 1 0.000 0.75 0,000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 100.000-80.00 0 T10 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 80.000-60.000 T11 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 60.000-40.000 T12 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 40.000-20.000 T13 0.000 1 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 0.000 0.75 20.000-0.000 Tower Section Geometry cont'd Tower Leg Leg Diagonal Top Gin Bottom Gin Mid Girt Long Horizontal Short Horizontal Elevation Connection Jl Type Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Site No. Bolt Size No. in in in in in in in Tl Flange 1.125 6 0.000 0 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 250.000-240.0 A325N A325N A325N A325N A325N A325N A325N 00 T2 Flange 1.125 6 0.000 0 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 240.000-220.0 ___ .- A325N A325N _ A325N A325N -- A325N A325N 'A325N - 00 13 - -Flange 1.125-6- -0.875- - -0.000_0- -0.000-n _L.625-0- n nOG---D-- - .625-0 - 220 000-200 0 - A32 - - - --T4---Flange 1.125 8 0.875 7 0.000 0 0.000 -0 0.625 0 -0.000 -0- 0.625 0 200.000-180.0 A325N A325N A325N A325N A325N A325N A325N 00 T5 Flange 1.125 8 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 180.000-160.0 A325N A325N A325N A325N A325N A325N A325N 00 T6 Flange 1.125 8 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 160.000-140.0 A325N A325N A325N A325N A325N A325N A325N 00 77 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 140.000-120.0 A325N A325N A325N A325N A325N A325N A325N 00 T8 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 120.000-100.0 A325N A325N A325N A325N A325N A325N A325N 00 )!`nxT(lw,er Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 7 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0165 Tower Elevation f Leg Connection Type Leg Bolt Size No. Diagonal Top Gin Bottom Girt Mid Girt Lang Horizontal Short Horizontal Bolt Size No. Bolt Size No. Bolt Size No. Bolt Sue No. Bolt Size No. Bolt Size No. in in in in in in in T9 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 100.000-80.00 A325N A325N A325N A325N A325N A325N A325N 0 T10 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 80.000-60.000 A325N A325N A325N A325N A325N A325N A325N Tll Flange LM 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 60.00040.000 A325N A325N A325N A325N A325N A325N A325N T12 Flange 1.125 12 0.875 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 40.000-20.000 A325N A325N A325N A325N A325N A325N A325N T13 Flange 1373 0 0.975 1 0.000 0 0.000 0 0.625 0 0.000 0 0.625 0 20.000-0.000 A449 A325N A325N A325N A325N A325N A325N Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Face Allow Component Placement Face Lateral # # Clear Width or Perimeter Weight or Shield Type Offset Offset Per Spacing Diameter Leg ft in (Frac FW) Row in in in ldf LDF7-50A(1- A No At (CaAa) 248.000 - 0.000 0.000 -0.42 6 6 0.850 1.980 0.001 5/8) 0.750 (E) LDF6-50A(1- A No Ar(CaAa) 248.000 - 0.000 0.000 -0.38 3 3 0.850 1.550 0.001 1/4") 0.750 (F) Feedline A No Af (CaAa) 248.000 - 0.000 0.000 -0.4 1 1 3.000 3.000 0.008 Ladder (Ai) (E) •adw> 9207(5/8") C No As (CaAa) 125.500 - 0.000 0.000 0.48 2 2 0.350 0.330 0.001 (E-lighting Cable) 9207(5/8") C No At (CaAa) 250.000-125.500 0.000 0.48 1 1 0.350 0.330 0.001 (E-ligbting Cable) -*ds. Safety Line ._C No Ar(CaAa) 250.000 - 0.000 0.000 -_ - OS 1. I 0.375 0.375 0.000 3/8 Feed Line/Linear Appurtenances Section Areas Tower Tower Face Aft Ar CA, CtA� Weight Section Elevation In Face Out Face ft ftr fl, fr ft' K T1 250.000-240.000 A 0.000 0.000 17.224 0.000 0.122 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 0.705 0.000 0.008 T2 240.000-220.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 73 220.000-200.000 A 0.000 0.000 43-060 0.000 0.306 MxTower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) Page 8 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 SBoulder Ave, Suite 300 Tulsa, OK 74119 Phone: (918) 587-4630 FAX.- (918) 295-026S Client SBA Communications Corporation Designed by B. Sevier Tower Tower Face AR AF C�A� CA Weight Section Elevation In Face Out Face R f' fit Its fit, K B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T4 200.000-180.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 TS 180.000-160.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 IAIO 0.000 0.016 T6 160.000-140.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.410 0.000 0.016 T7 140.000-120.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 1.591 0.000 0.020 T8 120.000-100.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T9 100.000-80.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T10 80.000-60.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 Tll 60.00040.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T12 40.000-20.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 T13 20.000-0.000 A 0.000 0.000 43.060 0.000 0.306 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 2.070 0.000 0.028 Feed Line Center of Pressure Section Elevation CPa CPi CPa CPz Ice Ice T1 250.000-240.000 -3.854 1.633 4.432 1.859 - --T5 180.000-160.000 -6.852 3.043 -7.878 - 3-.476 T6 160.000-140.000 -7.947 3.556 -9.134 4.062 T7 140.000-120.000 -8.519 3.838 -9.786 4.382 T8 120.000-100.000 -9A94 4.309 -10.889 4.912 T9 100.000-80.000 -9.698 4.414 -11.122 5.032 TIO 80.000-60.000 -9.763 4.453 -11.195 5.077 T11 60.00040.000 -10.264 4.690 -11.769 5348 T12 40.000-20.000 -9.610 4.398 -11.019 5.016 T13 20.000-0.000 -10.009 4.587 -11.476 5231 �( Wx Qwer Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 9 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 SBoulder Ave, Suite 300 Tulsa, OK 74119 Phone. (918) 587-4630 FAX (918) 295-0265 Client SBA Communications Corporation Designed by B. Sevier Shielding Factor Ka Tower Feed Line Description Feed Line F. K. Section Record No. Se ent Elev. No ke Ice TI 2 LDF7-50A(1-5/8) 240.00- 0.6000 0.6000 248.00 T1 3 LDF6-50A(I-1/4") 240.00- 0.6000 0.6000 248.00 T1 4 Feedline Ladder (Al) 240.00- 0.6000 0.6000 248.00 T1 7 9207(5/8'� 240.00- 0.6000 0.6000 250.00 Tl 9 Safety Line 3/8 240.00- 0.6000 0.6000 250.00 T2 2 LDF7-50A(1-5/8) 220.00- 0.6000 0.6000 240.00 T2 3 LDF6-50A(I-I/4") 220.00- 0.6000 0.6000 240.00 T2 4 Feedliue Ladder (At) 220.00- 0.6000 0.6000 240.00 T2 7 9207(5/8") 220.00- 0.6000 0.6000 240.00 T2 9 Safety Line 3/8 220.00- 0.6000 0.6000 240.00 T3 2 LDF7-50A(I-5/8) 200.00- 0.6000 0.6000 220.00 - T3 3 LDF6-50A(1-1/4") 200.00- 0.6000 0.6000 220.00 T3 4 Feedline Ladder (Al) 200.00- 0.6000 0.6000 220.00 T3 7 9207(5/8") 200.00- 0.6000 0.6000 220.00 T3 9 Safety Line 318 200.00- 0.6000 0.6000 220.00 T4 2 LDF7-50A(1-5/8) 180.00- 0.6000 0.6000 200.00 T4 3 LDF6-50A(I-1/4") 180.00- 0.6000 0.6000 200.00 T4 4 Feedline Ladder (Al) 180.00- 0.6000 0.6000 200.00 T4 7 9207(5/8") 180.00- 0.6000 0.6000 - T41----__ 9 T5 4 Feedline Ladder (Al) 160.00- 0.6000 180.00 T5 7 9207(5/8") 160.00- 0.6000 180.00 T5 9 Safety Line 318 160.00- 0.6000 180.00 T6 2 LDF7-50A(I-5/8) 140.00- 0.6000 160.00 T6 3 LDF6-50A(1-1/4") 140.00- 0.6000 160.00 T6 4 Feedline Ladder (A1) 140.00 - 0.6000 160.00 T6 7 9207(5/8") 140.00- 0.6000 160.00 T61 9 Safety Line 3/81 140.00- 0.6000 WXToxver Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 10 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 SBoulder Ave, Suite 300 Tulsa, OK 74119 Phone: (918) 587-4630 FAX. (918) 295-0265 Client SBA Communications Corporation Designed by B. Sevier Tower Feed Line Description Feed Line K. K. Section Record No. Se mentBlev. No ke Ice 160.00 T7 2 LDF7-50A(1-5/8) 120.00- 0.6000 0.6000 140.00 T7 3 LDF6-50A(1-1/4") 120.00- 0.6000 0.6000 140.00 T7 4 Feedline Ladder (At) 120.00- 0.6000 0.6000 140.00 T7 6 9207(5/8") 120.00- 0.6000 0.6000 125.50 T7 7 9207(5/8") 125.50- 0.6000 0.6000 140.00 T7 9 Safety Line 318 120.00- 0.6000 0.6000 140.00 T8 2 LDF7-50A(1-5/8) 100.00- 0.6000 0.6000 120.00 T8 3 LDF6-50A(1-1/4") 100.00- 0.6000 0.6000 120.00 TS 4 Feedline Ladder (Ai) 100.00- 0.6000 0.6000 120.00 TS 6 9207(5/8") 100.00- 0.6000 0.6000 120.00 T8 9 Safety Line 3/8 100.00- 0.6000 0.6000 120.00 T9 2 LDF7-50A(1-5/8) 80.00-100.00 0.6000 0.6000 T9 3 LDF6-50A(1-1/4") 80.00-100.00 0.6000 0.6000 T9 4 Feedline Ladder (At) 80.00 - 100.00 0.6000 0.6000 T9 6 9207(5/8") 80.00- 100.00 0.6000 0.6000 T9 9 Safety Line 3/8 80.00 - 100.00 0.6000 0.6000 T10 2 LDF7-SOA(1-5/8) 60.00-80.00 0.6000 0.6000 TIO 3 LDF6-50A(1-1/4") 60.00-80.00 0.6000 0.6000 TIO 4 Feedline Ladder (At) 60.00 - 80.00 0.6000 0.6000 TIO 6 9207(5/8") 60.00 - 80.00 0.6000 0.6000 T10 9 Safety Line 3/8 60.00 - 80.00 0.6000 0.6000 T11 2 LDF7-50A(1-5/8) 40.00-60.00 0.6000 0.6000 Tit 3 LDF6-50A(1-1/4") 40.00-60.00 0.6000 0.6000 Tit 4 Feedliae Ladder (At) 40.00 - 60.00 0.6000 0.6000 Tll 6 9207(5/8') 40.00-60.00 0.6000 0.6000 T11 9 Safety Line 318 40.00 - 60.00 0.6000 0.6000 T12 2 LDF7-50A(1-5/8) 20.00-40.00 0,6000 0.6000 T12 3 LDF6-50A(I-1/4") 20.00-40.00 0.6000 0.6000 T12 4 Feedline Ladder (At) 20.00 - 40.00 0.6000 0.6000 T12 9207(5/8") 20.00-40.00 0.6000 0.6000 TL2 _ _6 9 _ _ __ Safety Line 3/8 20.00-40:00 0.6000- 0.6000 T13 2 LDF7-50A(I-5/8) 0.00 - 20.001 -U00=-20:00-03000-`0:600 0.60001 0.6000 �173 - 3--LI5Fb3DX(1=I74') ��eedhne Ladder - - - . 13 --6- 9 -- - --9207(5/8") Safety Line 3/8 0.00-20.00 0.00 - 20.00 -0.6000 0.6000 -0.6000 0.6000 T13 tnxTow,e Job Page' 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 11 of 26 Project Date B+T Group 1717SBoulderAve, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX- (918) 295-0265 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement C, 41 CylA Weight or Type llorz Adjustment Front Side Leg Lateral Iren fr fi fr' f? K !t fr Lightning Rod 5/8" x 4' on b' A From Leg 0.000 0.000 255.000 No Ice 2.339 2.339 0.085 Pole 0.000 (E) 0.000 Strobe C From Leg 0.000 0.000 251.000 No Ice 5.250 3.500 0.020 (E) 0.000 0.000 Side Lighting A From Leg 0.500 0.000 125.500 No Ice 0.133 0.133 0.005 (E) 0.000 0.000 Side Lighting B From Leg 0.500 0.000 125.500 No Ice 0.133 0.133 0.005 (E) 0.000 0.000 Side Lighting C From Leg 0.500 0.000 125.500 No Ice 0.133 0.133 0.005 (E) 0.000 0.000 •rdri (2) CMA-BDBH/6520/E0-8 A From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 (2) CMA-BDMV6520/E0-8 B From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 (2) CMA-BDM6520/E0-8 C From Leg 4.000 0.000 248.000 No Ice 10.224 5.099 0.085 w/ Mount Pipe 0.000 (E) 0.000 FXFB A From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 FXFB B From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 FXFB C From Leg 4.000 0.000 248.000 No Ice 4.128 1.123 0.050 (E) 0.000 0.000 FRIG A From Leg 4.000 0.000 248.000 No Ice 2.797 1.096 0.048 0.000 FRIG H From Leg 4.000 0:000---248.000-No cF a 2.797 1-.096 0.048 0.000 0.000 FRIG C From Leg 4.000 0.000 248.000 No Ice 2.797 1.096 0.048 (E) 0.000 0.000 FRIE A From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 FREE B From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 FRIE C From Leg 4.000 0.000 248.000 No Ice 4.128 1.112 0.055 (E) 0.000 0.000 ASU9338TYPOI A From Leg 4.000 0.000 248.000 No Ice 3.737 1.155 0.019 (E) 0.000 tuxTowei Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page12 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717 SBoulderAve, Suite 300 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 FAX (918) 295-0265 SBA Communications Corporation B. Sevier Description Face Offset Offsets: Azimuth Placement C Al CA41 Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft fil fr' K 0.000 ASU9338TYPOI B From Leg 4.000 0.000 248.000 No Ice 3.737 1.153 0.019 (E) 0.000 0.000 ASU9338TYPOI C From Leg 4.000 0.000 248.000 No Ice 3.737 1.155 0.019 (E) 0.000 0.000 DBXNH-6565E-A2M w/ A From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0.072 Mount Pipe 0.000 (P) 0.000 DBXNH-6565B-A2M w/ B From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0.072 Mount Pipe 0.000 (P) 0.000 DBXNH-6565B-A2M w/ C From Leg 4.000 0.000 248.000 No Ice 8.648 7.082 0,072 Mount Pipe 0.000 (P) 0.000 Sector Mount ISM 1303-3] C None 0.000 248.000 No Ice 30.200 30.200 1.104 (E) ..d.. Load Combinations Comb. Description Na. 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dcad+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg - No Ice 5 0.9 Dead+1.6 Wind 30 deg -No Ice 6 1.2 Dead+1.6 Wind 60 deg -No Ice 7 0.9 Dead+1.6 Wind 60.de- -No Ice - 9 0.9 Dead+1.6 Wind 90 deg -No Ice - - 12 L2Dcad+1.6-Wind-150.deg-.No Ice. 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg -No Ice 15 0.9 Dead+1.6 Wind 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wind 210 deg -No Ice 18 1.2 Dead+1.6 Wind 240 deg -No Ice 19 0.9 Dead+1.6 Wind 240 deg -No Ice 20 1.2 Dead+1.6 Wind 270 deg -No Ice 21 0.9 Dead+1.6 Wind 270 deg -No Ice 22 1.2 Dead+1.6 Wind 300 deg -No Ice 23 0.9 Dead+1.6 Wind 300 deg -No Ice 24 1.2 Dead+1.6 Wind 330 deg -No Ice 25 0.9 Dead+1.6 Wind 330 deg -No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service tnac1 over Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 13 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717SBoulderAve, Suite300 Tulsa, OK 74119 Phone: (918) 587-4630 FAX (918) 295-0265 Client SBA Communications Corporation Designed by B. Sevier Comb. Description No. 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg -Service 31 Dead+Wind I50 deg - Service 32 Dead+Wind 180 deg -Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service Maximum Member Forces Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip-ft .lip-ft TI 250-240 Leg Max Tension 7 19.049 0.821 -0.491 Max. Compression 18 -21.391 0.263 -0.156 Max. Mx 20 -1.027 -1.511 0.002 Max. My 2 -0.323 0.023 -1.513 Max. Vy 20 -3.206 0.276 -0.053 Max. Vx 2 -3.361 -0.011 0.304 Diagonal Max Tension 4 4.213 0.000 0.000 Max. Compression 16 -4.228 0.000 0.000 Max. Mx 18 0.543 -0.004 -0.000 Max. My 16 -3.809 -0.002 0.002 Max. Vy 18 -0.005 -0.004 -0.000 Max. Vx 16 -0.001 -0.002 0.002 Top Girt Max Tension 18 0.069 0.000 0.000 Max. Compression 7 -0.065 0.000 0.000 Max. Na 6 -0.065 0.006 0.000 Max. My 24 0.004 0.000 -0.000 Max. Vy 6 -0.006 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 Bottom Girt Max Tension 6 1.202 0.000 0.000 Max. Compression 19 -1.196 0.000 0.000 Max. Mx 6 1202 0.006 0.000 Max. My 24 0.058 0.000 -0.000 Max. Vy 6 -0.006 0.000 0.000 -- - - - - -Maxrvx 24 0:000 0.000 _ 0.000 - -- T2 240 - 220 Leg Max Tension 7 78.362 0.984 -0.590 ' -- - Max.`Compression-]S - 2.fr251:083 - 0;63 -- - - _ Max. My 2 -26.069 -0.061 1.563 _ Max. Vy 10 5.849 -1.085 -0.591 Max. Vx 2 -6.627 -0.032 1.238 Diagonal Max Tension 4 5.710 0.000 0.000 Max. Compression 16 -5.769 0.000 0.000 Max. Mx 18 4.541 -0.012 -0.000 Max. My 24 -5.129 0.004 -0.004 Max. Vy 18 0.009 -0.012 -0.000 Max. Vx 24 0.002 0.004 -0.004 Top Girt Max Tension 18 1.523 0.000 0.000 Max. Compression 6 -1.521 0.000 0.000 Max. Mx 6 -1.521 0.008 0.000 Max. My 24 -0.038 0.000 -0.000 Max. Vy 6 -0.008 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 Bottom Girt Max Tension 11 0.083 0.000 0.000 tnxTf wer Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 14 of 26 Project Date B+T Group 1717SBoulderAve, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918)295-0265 Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft 7ype Load Moment Moment Comb. K kipJl kip-/1 Max. Compression 10 -0.218 0.000 0.000 Max. Mx 6 0.055 0.008 0.000 Max. My 24 0.029 0.000 -0.000 Max. Vy 6 -0.008 0.000 0.000 Max. Vx 24 0.000 0.000 0.000 T3 220 - 200 Leg Max Tension 7 105.276 1.668 -0.030 Max. Compression 18 -112.181 0.709 -0.011 Max. Mx 18 -82.909 2.913 -0.059 Max. My 12 -2.680 0.016 -1.326 Max. Vy 10 -3.617 0.712 -0.034 Max. Vx 12 1.854 0.016 -1.326 Diagonal Max Tension IS 4.235 0.000 0.000 Max. Compression 2 -4.569 0.000 0.000 Max. Mx 16 1.658 0.038 -0.006 Max. My 4 4.260 -0.016 0.022 Max. Vy 16 -0.015 0.038 -0.006 Max. Vx 4 -0.007 0.000 0.000 T4 200 - 180 Leg Max Tension 7 129.430 2.356 -0.034 Max. Compression 18 -140.218 0.635 -0.008 Max. Mx 10 -110-725 3.419 -0.269 Max. My 12 4.026 -0.017 -1.649 Max. Vy 10 4.564 0.636 -0.047 Max. Vx 12 1.974 -0.001 -0.432 Diagonal Max Tension 4 4.420 0.000 0.000 Max. Compression 4 -4381 0.000 0.000 Max. Mx 20 1.811 0.031 0.001 Max. My 2 -4.163 -0.013 0.009 Max. Vy 20 0.014 0.031 0.001 Max. Vx 2 -0.002 0.000 0.000 TS 180 - 160 Leg Max Tension 7 153.275 3.068 -0.037 Max. Compression 18 -168.868 0.708 -0.007 Max. Mx 10 -138.571 4.058 -0.319 Max. My 12 -5.529 -0.016 -1.924 Max. Vy 10 -5.874 0.710 -0.050 Max. Vx 12 2.450 -0.007 -0.500 Diagonal Max Tension 4 5.167 0.000 0.000 Max. Compression 4 -S.121 0.000 0.000 Max. Mz 20 2.118 0.039 0.002 Max. My 2 -4.933 -0.005 0.011 Max. Vy 20 0.019 0.039 0.002 _ _Max.Vx. 2 -0.002 _ 0.000 0.000. T6 160 - 140 Leg Max Tension 7 177.393 3.883 -0.042 - - Max Vy 10 -7.257 0.734 -0.040 - - Max.Vx 12 2.980 -0.014 -0.485 Diagonal Max Tension 4 6.095 0.000 0.000 Max. Compression 4 -6.003 0.000 0.000 Max. Mx 20 2.470 0.049 0.004 Max. My 2 -5.807 0.008 0.012 M= Vy 20 0.026 0.049 0.004 Max. Vx 2 -0.002 0.000 0.000 T7 140 - 120 Leg Max Tension 23 202.442 5.091 -0.327 Max. Compression 18 -230.116 0.485 -0.005 Max. Mx 10 -227.815 -6.262 0.426 Max. My 12 -9.365 -0.006 -2.733 Max. Vy 10 -8.993 0.485 -0.040 Max. Vx 12 3.644 0.012 -0.421 Diagonal Max Tension 4 7.270, 0.000 0.000 Max. Compression 4 -7.172 0.000 0.000 WxTC wer Job Page15 100926.001.01 - TC SR-70, FL (Site# FL17050-A) of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Section Elevation Component Condition Gan Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip-Jt kip-ft Max. Mx 20 2.916 0.062 0.005 Max. My 2 -6.966 0.013 0.016 Max. Vy 20 0.029 0.062 0.005 Max. Vx 2 -0.003 0.000 0.000 T8 120 - 100 Leg Max Tension 23 228A01 5.724 -0.371 Max. Compression 18 -263.427 0.918 -0.006 Max. Mx 10 -227.922 7.235 -0.510 Max. My 12 -11.637 0.041 -3.169 Max Vy 10 -10.863 0.920 -0.049 Max. Vx 12 4.302 -0.015 -0.598 Diagonal Max Tension 4 8.504 0.000 0.000 Max. Compression 4 -8340 0.000 0.000 Max. Mx 20 3.361 0.102 0.009 Max. My 2 -8.129 0.036 0.021 Max. Vy 20 0.047 0.102 0.009 Max. Vx 2 -0.004 0.000 0.000 T9 100 - 80 Leg Max Tension 23 255.733 6.931 -0.434 Max. Compression 18 -298.996 0.996 -0.005 Max. Mx 10 -261.042 9.127 -0.593 Max. My 12 -14.268 0.056 -3.839 Max. Vy 10 -12.985 0.997 -0.039 Max. Vx 12 5.066 -0.018 -0.580 Diagonal Max Tension 4 10.000 0.000 0.000 Max. Compression 4 -9.765 0.000 0.000 Max. Mx 20 3.977 0.123 0.011 Max. My 2 -9.560 0.047 0.026 Max. Vy 20 0.052 0.123 0.011 Max. Vx 2 -0.004 0.000 0.000 T10 80 - 60 Leg Max Tension 23 284.328 7.801 -0.430 Max. Compression 18 -336.669 1.619 -0.015 Max. W 10 -296A33 10.678 -0.656 Max. My 12 -17.131 0.040 4.395 Max. Vy 10 -15288 1.624 -0.120 Max. Vx 12 5.897 0.032 -1.041 Diagonal Max Tension 4 11.406 0.000 0.000 Max. Compression 4 -11.248 0.000 0.000 Max. Mx 20 4.557 0.136 0.013 Max. My 2 -11.060 0.059 0.029 Max. Vy 20 0.053 0.136 0.013 Max. Vx 2 -0.004 0.000 0.000 Tll 60-_40 Leg - - -Max Tension 23 -313.909: - - 9.263 -0.521. -- --- Max. Compression 18 -377.161 1.333 -0.007 10 -33392t 13.086 -0.806-_.__. 479 -- - - - - - -- -- - M * My Max. Vy 12 - 10 - - -20 176 _ ---17.666 _ 0 142 1.336 -5 -0.062 - -- Max. Vx 12 - 6.670- -0.008 -0.818 - Diagonal Max Tension 4 13.182 0.000 0.000 Max. Compression 4 -12.943 0.000 0.000 Max. Mx 20 5.160 0.219 0.021 Max. My 2 -12.751 0.123 0.039 Max. Vy 20 0.085 0.219 0.021 Max. Vx 2 -0.005 0.000 0.000 T12 40 - 20 Leg Max Tension 23 344.639 11.483 -0.612 Max. Compression 18 -419.997 0.361 0.001 Max. Mx 10 416.724 -14.862 0.808 Max. My 12 -24.006 0.197 -5.837 Max. Vy 10 -20.273 0.359 0.003 Max. Vx 12 7.593 -0.017 -0.385 Diagonal Max Tension 2 15232 0.000 0.000 Max. Compression 4 -14.796 0.000 0.000 Max, NIX 20 5.887 0.283 0.026 tt xTower Jab Page 16 of 26 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Project Date B+T Group 1717 SBoulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 5874630 SBA Communications Corporation B. Sevier FAX: (918) 295-0265 Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-f7 Minor Ads Moment kO-ff Max. My 2 -14.584 0.139 0.053 Max. Vy 20 0.099 0.283 0.026 Max. Vx 2 -0.007 0.000 0.000 T13 20-0 Leg Max Tension 23 376.311 13.157 -0.644 Max. Compression 18 -464.430 0.000 0.000 Max. Mx 10 -460.971 -17.283 0.860 Max. My 12 -28.237 0.214 -6.096 Max. Vy 10 -23.017 0.000 0.000 Max. Vx 12 8.108 0.000 -0.000 Diagonal Max Tension 2 16.847 0.000 0.000 Max. Compression 4 -16.429 0.000 0.000 Max Mx 8 6.752 0.310 -0.030 Max. My 2 -16.083 0.158 0.055 Meet. Vy 8 0.105 0.310 -0.030 Max. Vx 2 -0.007 0.000 0.000 Maximum Reactions Location Condition Gov. Vertical Horizontal, X Horbontal, Z Load K K K Comb. Leg C Max. Vert 18 462.653 40.309 -23.413 Max. H, 18 462.653 40.309 -23.413 Max. H: 5 -327.300 -28.056 21.186 Min. Vert 7 -373.724 -34.092 19.814 Min. H. 7 -373.724 -34.092 19.814 Min. H, 18 462.653 40.309 -23.413 Leg Max. Vert 10 459.274 40.799 -22.385 Max. H, 23 -374.594 34.598 18.884 Max H. 25 -328.027 28.898 19.565 Min. Vert 23 -374.594 34.598 18.884 Min. H. 10 459.274 -40.799 -22.385 Min. H, 10 459.274 -40.799 -22.385 Leg Max. Vert 2 459.554 -1.077 46.529 Max. H, 19 -192.180 7.029 -21.081 Max H, 2 459.554 -1.077 46.529 Min. Vert 15. -374.385 0.994. _-39.401 Min. H. 9 23.274 -6.408 1.704 Tower Mast Reaction Summary Load Yertical Shear. Shear. Overturning Overturning Torque Combination Moment, M. Moment, M_ K K K Idp ft kip-ft kip-ft Dead Only 77.314 0.000 0.000 11.209 25.217 0.000 1.2 Dead+1.6 Wind deg -No 92.776 0.047 -78.989 -9280.083 18.550 -48.181 Ice 0.9 Dead+1.6 Wind deg -No 69.582 0.047 -78.989 -9275.082 10.958 -48.150 Ice 1.2 Dead+1.6 Wind 30 deg -No 92.776 36.443 -63.026 -7594.805 -4375.955 -26.087 Ice 0.9 Dead+1.6 Wind 30 deg -No 69.582 36.443 -63.026 -7591.243 -4379.543 -26.068 WxTower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 17 of 26 Project Date B+T Group 1717 SBouLder Ave; Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Load Vertical Shear, Shear. Overturning Overturning Torque Combination Moment, M, Moment, At K K K kin-(t kip-11 kip-)? 1.2 Dead+1.6 Wind 60 deg -No 92.776 61.258 -35.368 -4299.616 -7440.137 4.777 Ice 0.9 Dead+1.6 Wind 60 deg - No 69.582 61.258 -35.368 -4299.044 -7440.900 -4.773 Ice 1.2 Dead+1.6 Wind 90 deg -No 92.776 72.804 -0.047 1.650 -8761.772 20.693 Ice 0.9 Dead+1.6 Wind 90 deg - No 69.582 72.804 -0.047 -1.720 -8761.359 20.681 Ice 1.2 Dead+1.6 Wind 120 deg - 92.776 68.430 39.454 4650.052 -8024.013 45.401 No Ice 0.9 Dead+1.6 Wind 120 deg - 69.582 68.430 39.454 4642.493 -8024.356 45.374 ' No Ice 1.2 Dead+1.6 Wind 150 deg - 92.776 36.361 62.979 7609.911 -4355.352 50.568 No Ice 0.9 Dead+1.6 Wind 150 deg - 69.582 36.361 62.979 7599.621 -4358.962 50.534 No Ice 1.2 Dead+1.6 Wind 180 deg - 92.776 -0.047 70.654 8619.093 42.309 41.841 No Ice 0.9 Dead+1.6 Wind 180 deg - 69.582 -0.047 70.654 8607.833 34.692 41.813 No Ice 1.2 Dead+1.6 Wind 210 deg- 92.776 -36,443 63.026 7621.725 4436.756 26.088 No Ice 0.9 Dead+1.6 Wind 210 deg- 69.582 -36.443 63.026 7611AOS 4425.128 26.069 No Ice 1.2 Dead+1.6 Wind 240 deg- 92.776 -68.477 39.535 4670.556 8096.644 5.452 No Ice 0.9 Dead+1.6 Wind 240 deg - 69.582 -68.477 39.535 4662.976 8081.765 5.448 No Ice 1.2 Dead+1.6 Wind 270 deg - 92.776 -72.804 0.047 25.419 8822.474 -20.694 No Ice 0.9 Dead+1.6 Wind 270 deg- 69.582 -72.804 0.047 22.025 8806.851 -20.682 No Ice 1.2 Dead+1.6 Wind 300 deg- 92.776 -61.211 -35.286 4278.964 7488.993 -39.736 No Ice 0.9 Dead+1.6 Wind 300 deg - 69.582 -61.211 -35.286 -4278.412 7474.559 -39.712 No Ice 1.2 Dead+1.6 Wind 330 deg - 92.776 -36.361 -62.979 -7582.857 4416.187 -50.568 No Ice 0.9 Dead+1.6 Wind 330 deg- 69.582 -36.361 -62.979 -7579.321 4404.596 -50.534 No lee - -- Dead+Wiud0 deg - Service 77.314 0.008 -12.983 -1515.408 23.330 -7.914 Dead+Wind30:deg-Service 77.3L4 - s-990 -10359- ---- -4238.560 -698.540--- ----4.291 Dead+Wind 90 deg - Service 77.314 11.966 -0.008 9.285 -1418.983 Dead+�✓ind120deg-Service 77.314 11.248 6.485 772.868 -1297.806 _ _3.406 - 7.457 Dead+Wind 150 deg -Service 77.314 5.976 10.352 1259.079 -695.158 8.305 Dead+Wind 180 deg - Service 77.314 -0.008 11.613 1424.859 27.236 6.872 Dead+Wind 210 deg - Service 77.314 -5.990 10.359 1261.028 749.105 4.291 Dead+Wind 240 deg - Service 77.314 -11.255 6.498 776247 1350.319 0.896 Dead+Wind 270 deg - Service 77.314 -11.966 0.008 13.189 1469.545 -3.405 Dead+Wind 300 deg - Service 77.314 -10.061 -5.900 -693.883 1250,492 -6.527 Dead+Wind 330 deg - Service 77.314 -5.976 -10.352 -1236.605 745.724 -8.305 MxTower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A ) 18 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tuisa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX- (918) 295-0265 Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ %Error Camb. K K K K K K 1 0.000 -77.314 0.000 0.000 77.314 0.000 0.000% 2 0.047 -92.776 -78.989 -0.047 92.776 78.989 0.000% 3 0.047 -69.582 -79.989 -0.047 69.582 78.989 0.000% 4 36.443 -92.776 -63.026 -36.443 92.776 63.026 0.000% 5 36.443 -69.582 -63.026 -36.443 69.582 63.026 0.000% 6 61259 -92.776 -35.368 -61.258 92.776 35.368 0.000% 7 61.259 -69.582 -35.368 -61.258 69.582 35.368 0.000% 8 72.804 -92.776 -0.047 -72.804 92.776 0.047 0.000% 9 72.804 -69.582 -0.047 -72.804 69.582 0.047 0.000% 10 68.430 -92.776 39.454 -68.430 92.776 -39.454 0.000% 11 68.430 -69.582 39.454 -68.430 69.582 -39.454 0.000% 12 36.361 -92.776 62.979 -36.361 92.776 -62.979 0.000% 13 36.361 -69.582 62.979 -36.361 69.582 -62.979 0.000% 14 -0.047 -92.776 70.654 0.047 92.776 -70.654 0.000% 15 -0.047 -69.582 70.654 0.047 69582 -70.654 0.000% 16 -36.443 -92.776 63.026 36.443 92.776 -63.026 0.000% 17 -36.443 -69.582 63.026 36.443 69582 -63.026 0.000% 18 -68.477 -92.776 39.535 68.477 92.776 -39.535 0.000% 19 -68.477 -69.582 39.535 68.477 69.582 -39.535 0.000% 20 -72.804 -92.776 0.047 72.804 92.776 -0.047 0.000% 21 -72.804 -69.582 0.047 72.804 69.582 -0.047 0.000% 22 -61.211 -92.776 -35.286 61.211 92.776 35.286 0.000% 23 -61.211 -69.582 -35.286 61.211 69582 35.286 0.000% 24 -36.361 -92.776 -62.979 36.361 92.776 62.979 0.000% 25 -36.361 -69.582 -62.979 36.361 69.582 62.979 0.000% 26 0.008 -77.314 -12.983 -0.008 77.314 12.983 0.000% 27 5.990 -77.314 -10.359 -5.990 77.314 10.359 0.000% 28 10.069 -77.314 -5.813 -10.069 77.314 5.813 0.000% 29 11.966 -77.314 -0.008 -11.966 77.314 0.008 0.000% 30 11.248 -77.314 6.485 -11.248 77.314 -6.485 0.000% 31 5.976 -77.314 10.352 -5.976 77.314 -10.352 0.000% 32 -0.008 -77.314 11.613 0.008 77.314 -11.613 0.000% 33 -5.990 -77.314 10.359 5.990 77.314 -10.359 0.000% 34 -11.255 -77.314 6.498 11.255 77.314 -6.498 0.000% 35 -11.966 -77.314 0.008 11.966 77.314 -0.008 0.000% 36 -10.061 -77.314 -5.800 10.061 77.314 5.800 0.000% 37 -5.976 -77.314 -10.352 5.976 77.314 10.352 0.000% ---- ---Non-Unear Convey ence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00000206 3 Yes 4 0.00000001 0.00000194 4 Yes 4 0.00000001 0.00000131 5 Yes 4 0.00000001 0.00000126 6 Yes 4 0.00000001 0.00000107 7 Yes 4 0.00000001 0.00000110 8 Yes 4 0.00000001 0.00000128 9 Yes 4 0.00000001 0.00000124 10 Yes 4 0.00000001 0.00000203 11 Yes 4 0.00000001 0.00000192 t Tower Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 19 of 26 Project Date B+T Group 1717 SBoulderAve, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAR.- (918) 295-0265 12 Yes 4 0.00000001 0.00000153 13 Yes 4 0.00000001 0.00000146 14 Yes 4 0.00000001 0.00000121 15 Yes 4 0.00000001 0.00000121 16 Yes 4 0.00000001 0.00000132 17 Yes 4 0.00000001 0.00000127 18 Yes 4 0.00000001 0.00000187 19 Yes 4 0.00000001 0.00000176 20 Yes 4 0.00000001 0.00000129 21 Yes .4 0.00000001 0.00000125 22 Yes 4 0.00000001 0.00000119 23 Yes 4 0.00000001 0.00000120 24 Yes 4 0.00000001 0.00000153 25 Yes 4 0.00000001 0.00000146 26 Yes 4 0.00000001 0.00000001 27 Yes 4 0.00000001 0.00000001 28 Yes 4 0.00000001 0.00000001 29 Yes 4 0.00000001 0.00000001 30 Yes 4 0.00000001 0.00000001 31 Yes 4 0.00000001 0.00000001 32 Yes 4 0.00000001 0.00000001 33 Yes 4 0.00000001 0.00000001 34 Yes 4 0.00000001 0.00000001 35 Yes 4 0.00000001 0.00000001 36 Yes 4 0.00000001 0.00000001 37 Yes 4 0.00000001 0.00000001 Maximum Tower Deflections - Service Wind Section Elevation Harz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° TI 250-240 3.322 34 0.149 0.036 T2 240-220 3.006 34 0.146 0.035 T3 220 - 200 2.423 34 0.118 0.032 T4 200 - 180 1.957 34 0.096 0.025 TS 180 - 160 1.569 34 0.081 0.021 T6 160 - 140 1.240 34 0.068 0.017 T7 140 - 120 0.960 34 0.057 0.015 T8 120 - 100 0.719 34 0.049 0.012 - T9 _ _ __100_:80 _ 0.521- _ _34 0.038 ___0.010 _ T10 80-60 0.357 34 0.029 0.008 T12 - 40-20 ___0.123 _34 0.014_ 0.004 T13 2b - 0 0.056 30 - 0.007 0.002 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Till Twist Radius of Load Curvature ft Comb. in ft 255.000 Lightning Rod 5/8" x 4' on 6' Pole 34 3.322 0.149 0.036 186839 251.000 Strobe 34 3.322 0.149 0.036 186839 248.000 (2) CMA-BDHH/6520/EO-8 w/ 34 3.258 0.149 0.036 186839 Mount Pipe 125.500 Side Lighting 34 0.781 0.050 0.013 113280 t=TO' er Job Page20 100926.001.01 - TC SR-70, FL (Site# FL17050-A) of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX: (918) 295-0265 Maximum Tower Deflections - Design Wind Twist Section Elevation Har_. Gov. Tilt No. Deflection Load p in Comb. ° Tl 250-240 19.936 18 0.893 0222 T2 240 - 220 18.043 18 0.875 0.215 T3 220 - 200 14.555 l8 0.704 0.195 T4 200 - 180 11.762 18 0.576 0.154 T5 180 - 160 9.435 18 0.486 0.126 T6 160 - 140 7.459 18 0.409 0.106 77 140 - 120 5.780 18 0.343 0.090 T8 120 -100 4.338 18 0.285 0.073 T9 100 - 80 3.146 18 0.22.6 0.060 T10 80-60 2.161 18 0.173 0.047 T11 60-40 1.348 18 0.126 0.033 T12 40 - 20 0.747 18 0.082 0.022 T13 20-0 0.305 10 0.041 0.011 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature R Comb. in oft 255.000 Lightning Rod 5/8" x 4' on 6' Pole 18 19.936 0.893 0.222 31194 251.000 Strobe 18 19.936 0.893 0.222 31194 248.000 (2) CMA-13DHH/6520/EO-8 w/ 18 19.555 0.892 0221 31194 Manor Pipe 125.500 Side Lighting 18 4.710 0.300 0.077 18919 Bolt Design Data Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria - - - NO. - - - - -7)pe -- -Grade - - - , Of -Loadper Load- - -Load - Ratio- - - - - - - - ft in Bobs Bolt K Allowable Eeg- 325N_1:WS as t --13.060- �c <� na _ _ -- 67.096- _I 0.195 V- --I- -- R - itTrnsicla - Bolt Tension- - - - -- - - - - - - T2 240 - Leg--- -A325N - 1.125- - - 6 T3 220 Leg A325N 1.125 6 17.546 67.096 0262 1/ 1 Bolt Tension Diagonal A325N 0.875 1 4235 11.166 0.379 I Member Block T4 200 Leg A325N 1.125 Diagonal A325N 0.875 T5 180 Leg A325N 1.125 Diagonal A325N 0.875 T6 160 Leg A325N 1.125 Diagonal A325N 0.875 Shear 8 16.179 67.096 I Bolt Tension 0241 1 4.420 10.413 1 Member Block 0424 ,� Shear 8 19.159 67.096 1 Bolt Tension 0286 1 5.167 13.884 1 Member Block 0372 Shear 8 22.174 67.096 1 Bolt Tension 0330 1 6.095 17.355 1 Member Block 0.351 Shear 1 'A Over Job Page 100926.001.01 - TC SR-70, FL (Site# FL17050-A) 21 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Client Designed by Tulsa, OK 74119 Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX- (918) 295-0265 Section Elevation Component Bolt Bolt Sze Number Maximum Allowable Ratio Allowable Criteria No. Type Grade Of Loadper Load Load Ratio ft in Bolts Bolt K Allowable K T7 140 Leg A325N 1.125 12 16.870 67.096 0.251 1 Bolt Tension Diagonal A325N 0.875 1 7.270 15.244 0.477 1 Member Block Shear T8 120 Leg A325N 1.125 12 19.033 67.096 0284 1 Bolt Tension Diagonal A325N 0.875 1 8.504 22.866 0372 1 Member Block Shear T9 100 Leg A325N 1.I25 12 21.311 67.096 0.318 1 Bolt Tension Diagonal A325N 0.875 1 10.000 22.453 0.445 1 Member Block Shear T10 80 Leg A325N 1.325 12 23.694 67.096 0.353 1 Bolt Tension Diagonal A325N 0.875 1 11.406 17.962 0.635 1 Member Block Shear Tit 60 Leg A325N 1.125 12 26.159 67.096 0.390 1 Bolt Tension Diagonal A325N 0.875 1 13.182 24.354 0.541 1 Bolt Shear T12 40 Leg A325N 1.125 12 28.720 67.096 0428 1 Bolt Tension Diagonal A325N 0.875 1 15.232 24.354 0.625 1 Bolt Shear T13 20 Diagonal A325N 0.875 1 16.848 24.354 0.692 1/ 1 Bolt Shear Compression Checks Leg Design Data Compression Section Ratio Elevation See L L. KUr A P. No. P. ft ft ft in' K K OP„ TI 250-240 2 114 10.000 3.083 65.8 3.976-21.391 130.399 0.164' K=1.00 V -- - T2 - -240-220 21/2 - - 20.000" 3:208- - 6L6 --4.909- --82.625- '167.374 -0.494' - - - - K=1.00 _ T3_- - 220-200.. _ 3112 20.030 6.176 84.7 9.621 -106.954 256.230- 0.417' K=C00 T4 200 - 180 4 20.030 - -6.176 - 74.1 - -12.566- -135.211 378.448 0.357-' - - K=1.00 T5 180- 160 4 1/4 20.030 6.176 69.8 14.186 -163.640 447.281 0.366 ' K=1.00 T6 160- 140 4 1/2 20.030 6.176 65.9 15.904 -193.191 521.096 0.371' K=1.00 T7 I40-120 43/4 20.030 6.176 62.4 17.721 -224.217 599.797 0.374' K=1.00 `/ T8 120-100 43/4 20.030 6.176 62.4 17.721 -257.162 599.797 0.429' K=1.00 T9 100- 80 5 20.030 6.176 59.3 19.635 -292.242 683.313 0.428' K=1.00 T10 80-60 5 1/4 20.030 6.176 56.5 21.647 -329.438 771.566 0.427' K=1.00 tnxTow,er Job Page22 100926.001.01 - TC SR-70, FL (Site# FL17050-A) of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Section Elevation Mw L L„ Mr A P. Ratio No. P. ft ft jt in K K T11 60-40 5 12 20.030 6.176 53.9 23.758 -369.358 864.519 0.427' K=1.00 V T12 40-20 53/4 20.030 6.176 51.6 25.967 -411.623 962A28 0.428' K=1.00 I/ T13 20-0 53/4 20.030 6.176 51.6 25.967 -455.600 962.128 0.474' K=1.00 V t P. / r P„ controls Diagonal Design Data Compression Section Elevation Size L L KI/r A P. Ratio No. P ft ft ft in° K K V. Tl 250 -240 1 5.050 2.407 106.6 0.785 -4.228 13.997 0.302' K=0.92 `/ T2 240-220 1118 5.128 2.430 101.8 0.994 -5.769 18.668 0.309' K=0.98 `/ T3 220-200 L2x2xl/4 7.558 3.628 113.5 0.938 -4.569 15.422 0296' K=1.02 T4 200-180 L2 1/2x2 1/2x3/16 9.676 4.625 114.1 0.902 -4.381 14.728 0297' K=1.02 V T5 180-160 L2 1/2x2 1/2xl/4 11.213 5.383 131.6 1.190 -5.121 15.499 0.330' K=1.00 V T6 160-140 L2 1/2x2 1/2x5/16 12.851 6.192 152.0 1.460 -6.003 14.284 0.420' K=1.00 `/ T7 140 -120 L3x3xl/4 14.556 7.034 142.6 1.440 -7.172 16.000 0.448' K=1.00 `/ T8 120 -100 L3x3x3/8 16.306 7.911 161.7 2.110 -8.340 18.227 0.458' K=1.00 ,/ T9 100-80 L3 1/2x3 1/2x5/16 18.081 8.787 152.8 2.090 -9.765 20.218 0.483 ' K-1.00. _ _ _ 600,. T10 80 60 L4x41/4 19885 9680 1461 1940 11248 20530 0548' x T11 60-40 L4x4x3/8 21.709 10.581 16L1 2.860 -12943 24.883 0.520' - _ - - K=1.00. ___ _ - _ _ _ _`/. _ _ T12 40-20 L5x5x5/16 23.546 11.490 138.7 3.030 -14.796 35.576 0.416' K=1.00 `/ T13 20-0 L5x5x5/16 25.395 12.415 149.9 3.030 -16.429 30.474 0.539' K=1.00 `/ 1 P. / OP. controls WxTo er Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 23 of 26 Project Date 08:51:59 09/04/15 B+T Group 1717SBoulderAve, Suite 300 Tulsa, OK 74119 Phone: (918) 587-4630 FAX.(918) 295-0265 Client SBA Communications Corporation Designed by B. Sevier Top Girt Design Data Compression Section Elevation aze L L. KI/r A F. op. Ratio No. P. ft. ft Ji in2 K x 8,p- K=0.70 T2 240-220 11/8 4.000 3.792 113.2 0.994 -1.521 16.396 0.093' K=0.70 Pcontrols Bottom Girt Design Data Compression Section Elevation Sue L L. KI1r A P. gyp„ Ratio NO. P. ft ft ft in2 K K ,hp„ K-0.70 T2 240-220 1 1/8 4.000 3.792 113.2 0.994 -0.218 16.396 0.013' K=0.70 t P„ / QiP, controls Section Elevation No. Site Tension Checks Leg Design Data Tension L L KUr A P. �P„ Ratio P. - n'- - ft' - in' ' _ _ _ K K' IM1P_ T2 240 - 220 212 20.000 0.375 7.2 4.909 78.362 220.893 0.355 ' T3 220-200 3 12 20.030 0.751 10.3 9.621 105.276 432.951 0.243 ' T4 200-180 4 20.030 0.751 9.0 12.566 129.430 565.487 0.229' T5 180-160 41/4 20.030 0.751 8.5 14.186 153.275 638.381 0240' T6 160-140 4 112 20.030 0.751 8.0 15.904 177.393 715.694 0.248' T7 140 - 120 4 3/4 20.030 0.751 7.6 17.721 202.442 797.425 0.254' T8 120 - 100 4 314 20.030 0.751 7.6 17.721 228AOI 797.425 0286' tli,�Tower Job 100926.001.01 - TC SR-70, FL (Site# FL17050-A) Page 24 of 26 Project Date 08:51:59 09/04/15 B+T Group 1777 SRoulder Ave, Suite 300 Tulsa, OK 74119 Phone: (918) 587-4630 FAX.- (918) 295-0265 Client SBA Communications Corporation Designed by B. Sevier Section Ehnnulan Site L L„ KUr A P. �P„ Ratio No. P ft ft ft in' K K 6P„ TIO 80-60 51/4 20.030 0.751 6.9 21.647 284.328 Tl l 60 - 40 5 112 20.030 0.751 6.6 23.758 313.909 T12 40-20 5314 20.030 0.751 6.3 25.967 344.639 T13 20-0 53/4 20.030 0.751 6.3 25.967 376.311 I P. l V. controls 974.139 0.292' 1/ 1069.120 0294' 1168.530 0295' 1168.530 0.322' Diagonal Design Data Tension Ratio Section Elevation Size L L KUr A P. OP. No. P ft It S W K K W, Tl 250-240 1 5.050 2.407 115.5 0.785 4.213 25.447 0.166' T2 240-220 11/8 5.128 2.430 103.7 0.994 5.710 32.206 0.177' T3 2.20-200 L2x2xl/4 7.558 3.628 75.2 0.516 4.235 22.446 0.189' T4 200-180 L2 1/2x2 1/2x3/16 9.676 4.625 74.2 0.536 4.420 23.311 0.190, T5 I80-160 L21/2x21/2x1/4 11.213 5.383 86.9 0.705 5.167 30.668 0.168' T6 160-140 L2 1/2x2 1/2x5/16 12.851 6.192 100.6 0.861 6.095 37.437 0.163 ' T7 140-120 L3x3xl/4 14.556 7.034 93.2 0.892 7.270 38.824 0.187' T8 "120= 100 L3x3x3/8 ----"- 16:306 7.911 106.4 1-.301 -- 8.504 56.604-- -0.150-' - - --- -T10 80-60 LAx4xl/4 -19.885 9.680 94.7 1.268 11.406 55.136 0.207' T11 60-40 L4x4x3/8 21.709 10.581 105.1 1.864 13.182 81.073 0.163 ' T12 40-20 L5z5x5/l6 23.546 11.490 89.3 2.038 15.232 88.658 0.172' T13 20 - 0 LSx5x5/16 25.395 12.415 96.3 2.038 16.848 88.658 0.190, I P � / e. controls WxTowe Job Page 100926.001.01 - TC SR-70, FL (Site# FL17O50-A) 25 of 26 Project Date B+T Group 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX (918) 295-0265 Top Girt Design Data Tension Section Elevation Site L L. Kl/r A P. ell Ratio No. P ft ft ft in' K K V. Tl 250-240 1 4.000 3.813 183.0 0.785 0.069 25.447 0.003' T2 240-220 11/8 4.000 3.792 161.8 0.994 1.523 32.206 0.047' I P u / OP. controls Bottom Girt Design Data Tension Section Elevation Size L L. K71r A P. �P, Ratio No. P ft ft ft in2 K K mP„ TI 250 - 240 12 240 - 220 1 1/8 I P„ / V, controls 4.000 3.813 183.0 0.785 4.000 3.792 161.8 0.994 Section Capacity Table 1.202 25.447 0.047 0.083 32.206 0.003' Section Elevation Component Size Critical P oPyr„. % Pass Na ft Type Element K K Capacity Fail TI 250-240 Leg 21/4 1 -21.391 130.399 16.4 Pass T2 240-220 Leg 212 28 -82.625 167.374 49.4 Pass T3 220-200 Leg 3 12 73 -106.954 256.230 41.7 Pass T4 200 -180 Leg 4 94 -135.211 378.448 35.7 Pass - TS 180=160 Leg 4114 1.15 -163.640 447.281 36:6 Pass "- T6 160 -140 Leg 4 12 136 -193.191 521.096 37.1 Pass T7�40=120L-eg � - -- 43/4 157------224217--599:7973`Y.4--P T9 10080 _ _ Leg _ 5 _199 _-292.242 683.313 42.8 _ --Pass T10 80-60 Leg 51/4 220 -329.438 771.566 42.7 Pass Tll 60-40 Leg 51/2 241 -369.358 864.519 42.7 Pass T12 40-20 Leg 53/4 262 411.623 962.128 42.8 Pass 42.8 (b) T13 20 - 0 Leg 5 314 283 -455.600 962.128 47.4 Pass TI 250-240 Diagonal 1 15 4.228 13.997 302 Pass T2 240-220 Diagonal 1 118 42 -5.769 18.668 30.9 Pass T3 220-200 Diagonal L2x2xl/4 92 -4.569 15.422 29.6 Pass 37.9 (b) T4 200- 180 Diagonal L2 1/2x2 1/20/16 101 -4.381 14.728 29.7 Pass 42.4 (b) T5 180-160 Diagonal L212x212xl/4 122 -5.121 15.499 33.0 Pass 37.2 (b) T6 160-140 Diagonal L212x21/2x5/16 143 -6.003 14.284 42.0 Pass T7 140-120 Diagonal L3x3xl/4 164 -7.172 16.000 44.8 Pass f t"XTOW,er Job Page 100926.001.01 - TC SR-70, FL (Site# FL17O50-A) 26 of 26 B+T Group Project Date 1717 S Boulder Ave, Suite 300 08:51:59 09/04/15 Tulsa, OK 74119 Client Designed by Phone: (918) 587-4630 SBA Communications Corporation B. Sevier FAX.- (918) 295-0265 Section Elevation Component See Critical P epwi, % Pass No. .h Type Element K K Capacity Fail 47.7 (b) T8 120- 100 Diagonal L3x3x3/8 185 -8.340 18227 45.8 Pass T9 100- 80 Diagonal L3 1/2x3 112x5/16 206 -9.765 20.218 48.3 Pass T10 80 -60 Diagonal L4x4xl/4 227 -11.248 20.530 54.8 Pass 63.5 (b) T11 60 -40 Diagonal L4x4x3/8 248 -12.943 24.883 52.0 Pass 54.1 (b) T12 40-20 Diagonal L5x5x5/16 269 -14.796 35.576 41.6 Pass 62.5 (b) T13 20- 0 Diagonal L5x5x5/16 290 -16.429 30.474 53.9 Pass 692 (b) Tl 250 - 240 Top Girt 1 5 -0.065 10.727 0.6 Pass T2 240 - 220 Top Girt 1 1/8 32 -1.521 16.396 93 Pass Tl 250-240 Bottom Girt 1 8 -1.196 10.727 11.2 Pass T2 240-220 Bottom Girt 11/8 36 -0.218 16.396 1.3 Pass Summary Leg (T2) 49.4 Pass Diagonal 69.2 Pass (T13) Top Girt 9.3 Pass (T2) Bottom Girt 112 Pass (TO Bolt Checks 69.2 Pass RATING= 69.1 Pass Program Version 6.1.4.1 - 12/17/2013 APPENDIX B BASE LEVEL DRAWING Feed Line Plan (6) 7 C n B+T Group 1717 S Boulder Ave, Suite 300 s.r Gr:p Tulsa, OK 74119 Phone: (918) 587-4630 FAX: 918 295-0265 °b: 100926.001.01- TC SR-70, FL Site# FL17050-A F' II Crene SBA Communications Corpombo °ra'xn B. S Me ^PP'd' Code: TIA-222-G Care:09/04/15 Smte: NTS . °v'9 Na. E_7 APPENDIX C ADDITIONAL CALCULATIONS PROJECT TC SR-70 - FL17050-A, FL SUBJECT Anchor Rod Check for Self Supporting Towers DATE 09/04/15 PAGE 1 OF 1 CfB+T GRP 1717 S. Boulder, Suite 300 Tulsa, OK 74119 (918) 587-4630 Number of Anchor Rods: 12 Diameter: 1.375 in Strength (Fu): 105 ksi Eta Factor, q: 0.5 TIA-222-G Figure 4-4 & Section 4.9.9 Down load, Pu: 463 Kips Shear, Vu: 47 Kips Anchor Rod Result Max Rod (Cu+ Vu/�): 46.4 Kips Allowable Axial, m*Fu*Anet: 97.4 Kips Anchor Rod Capacity: tA7,!6/f Pass SS Drilled Pier Site Number. TCSR-70 Site Name: FL17050-A, FI Input TIA Revision: G AD 318 R naislon: 2008 Seismic Category: B �,orces i Compression 463 kips Compression Shear 47 kips Uplift 375 kips Uplift Shear 39 kips Add'1 Moment 0 k-ft Swelling Force 0 kips Faundallon Dimensions �• Pier Diameter: 12 ft EA. above grade: 0.5 it Depth below grade: 35 it Bell Diameter. it Bell Angie: deg MaNumb rr Number of Reborn of 90 Rebar Size: 9 Tie Size 4 Rebar tensile strength: 60 ksl Concrete Strength: 3000 psi Ultimate Concrete Strom D.003 infin Clear Cover to Ties: 6 in 5m1 Profile ' s6)r=1 7incknes_ From ;Ta Uni[Weight-Cdheiion '- Angle , UpliftSkin Comp.Skin .*Copal (ft) . (n (it) " (po) - .(Psr) .(deg) Friction(ksf) .FUNon(ksfl ' (W 1 1 0 1 115 0 a a 0 0 2 4 1 5 53 0 0 0 0 0 3 1 5 6 57 1000 0 0.4 DA a 4 2 6 8 57 0 40 0.4 0.4 0 5 2 8 10 57 100 a 0.4 0.4 a 6 19 10 29 57 0 35 0.8 0.8 0 7 6 29 35 57 0 32 1 1 20 AnalWls Remits Soil lateral Capacity Upliftoon, - Depth to Zero Shear. _ -- 17.2ft Max Moment, Mu: 4]5.9 k-ft Soil Axial Capacity — Concrete Weight 326.1 kips Skin FrlNon: 656.0 kips Soil Cone: kips Uplift Capacity (k), tiTn: 992.0 kips Uplift (it), To: 375.0 kips RATING;'--- 38106 Skin Friction (k): 655.0 kips End Bearing (k): 1695.5 kips Comp. Capacity (k), 4,Cn: 2352.4 kips Comp. (it), Cu: 40.0 kips RATING:—'--" 'IT.68% Concrete/Starl Check Me (From soil m.1ys_) QMn the provlded she required Rebar Spacing Spacing required Dev. Length required Dev. Length provided 0.55 033'01( EA 18.0 Ol i 173 _ 49.4`K Page 1 of 1 PROJECT 100926.001.01 - TC SR-70, FL laws B+T GRP SUB]ECi pad Footing Analysis 1717 S. Boulder, Suite 300 Tulsa, OK 74119 DATE 09/04/15 PAGE 1 OF 1 (918) 587-4630 100926 001 01_SSDnfledPierrivn Combined Footinq Foundation Analysis Design Loads: Input factored loads Compression per leg (Pc) = 463.0 (k) Tension per leg (PT) = 375.0 (k) Overturning Moment (Mo) = 9,347.0 (k) Total Tower Horizontal Load = 79.0 (k-ft) Tower + Appurtenances = 93.0 (k) Pad & Pier Dimensions / Prooertles: Tower Shape (triangle or square) = T Pier Shape (round or square) = R Pier Diameter ( HP ) = 3.00 ( ft) Pier height above grade ( DA) = 0.50 ( ft) Footing Width ( WF ) = 47.00 ( ft) Footing Thickness ( HF) = 3.00 (ft) Depth to BOC ( D) = 7.00 ( ft) Concrete Strength ( F'c) = 3.00 ( ksi ) Reber Strength ( Py ) = 60.00 ( ksi) Ultimate Load Factor = 1.30 Min. Cover over Rebar = 3.00 ( in ) Qty of footing Rebar (1 layer) = 47 Size of footing Reber = # 9 ( bar ) Qty of Vertical Reber per Pier = 33 Size of Pier Vertical Reber = # 9 ( bar ) Qty of Rebar Ties per Pier = 11 Size of Pier Rebar Ties = # 4 ( bar ) Soil Data: -Soif�nng(ultimate) = 4000 ( psf ) Soil Cone for Uplift (0) = 30 ( degrees ) Cohesion (C) = 0.00 (ft) Top Soil to Neglect ( N) = 3.00 (ft) Base Sliding (p) = 0.35 ( ksf ) Dry Soil Density ( yDar) = 63 ( pcf ) Saftev Factors Uplift S.F. (Conc. Wt.) Uplift S.F. (Soil Wt.) Overturning S.F. Bearinging S.F. Tower Information Tower base width Plan View for Triangle or Sauare Tower V 0 47.00 ft Total Overview Rev. Type: G = 1.25 2.00 1.50 — 2.00 25.00 ft Summary of Results Overturing 42.6% Soil Bearing 34.7% Base Sliding 16.8% One way Shear 8.3% Punching Shear 42.6% Pad Moment Capacity 47.0% Pier Moment Capacity 12.5% Kimley*Horn August 12, 2015 MetroPCS Attn: Denise Correa 1000 Sawgrass Corporate Parkway, Suite 400 Ft. Lauderdale, FL 33323 RE: Antenna Mount Design L,e'tter Carrier Designation: MefroRE§ 700,MHz =Upgrade, CarnerSite Number: A2P03091W Cainer.Site Name: GTP 14WY 70 Site Data: 96666.Okeechobee Road, Fort Pierce;.F ,34945 St. Lucie Couirty To whom it may concern: In accordance with our agreement, Kimley-Horn and Associates, Inc. ("Kimley-Horn"), has performed an evaluation of the existing antenna mount for the above referenced site for the replacement of MetroPCS antennas. The purpose of this analysis is to compare the existing manufacturer's mount design specification with the proposed carrier loading conditions to determine if the proposed mount is structurally capable of supporting the proposed MetroPCS equipment under the loading of the TIA-222-G standard and the 2014 Florida Building Code. The proposed mount was checked against the required 117 mph nominal design wind loading (151 mph ultimate wind speed, Risk Category II, Exposure C per 2014 Florida Building Code). Per the specifications provided by MetroPCS, the existing and proposed antennas are as follows: - - • --(Existing) 6- CMA-BDHH16520/E0-8 antenna: 64 6"'x 15.9"x 5"; 62 lbs —(Existing)3= FRI E-RRU's:-1 9.3" x22" x 52"; 55.1-Ibs -- - — ---- - - • (Existing) 3-FRIG RRU's: 15.24" x 18.88" x 5.98"; 57.3 Ibs • (Existing) 3- FRLB RRU's: 15.75" x 15.75" x 5.9"; 59.52 Ibs (Proposed) 3- DBXNH-6565E-A2Mi 72.7" x 11.9" x 7.1"; 46.3 Ibs The existing mount, a Connect -It Wireless, 13' V-Frame Boom Gate, VF13-XX-96 is to be reused. Conservatively, no shielding is assumed on the RRU's. The COVP's are considered to be on a separate mount. kimley-horn.com '1920'Wekiva Way, Suite 200, West Palm Beach, FL'33411 561 845 0665` 0 Kimley»)Horn Page 2 Based on the comparative analysis listed below, it is our opinion that the existing mount will have sufficient capacity for the proposed carrier equipment. Please contact me at (561) 840-0232 or Kevin.Maraih(c kimley-horn.com should you have any questions. Sincerely, KfMLEY=HQRMA, NDASSOCIAT t;:tIV i CA 00000696 Kevin MarajKi Florida P.E. 71 Attachments., -'�rU111111W`' - — Kimley-Horn-700 MHz Upgrade -Plans -dated November-26,-2013, Sheet C-2. Connect -it Wireless 13' V-Frame Boom Gate VF13-XX-96, Design Specifications, 2014 Florida Building Code -Building Section 1620.2 (ki, ml'e'y�MUrnYcoml 10920'WdkivatWayj'Suife 200,"W,6!;t'Palm- each,-FL°33411 i RFDS Data Configuration Sheet Page I of 4 Uea. YALWASH T - -Mobilem 13;P Seek In RFDS home RFDS Data Configuration Sheet Date; 712712016 Go Seek 'Print RFDS Site Information: M.Open; FL RedE.Varid.n iNSN Plan Year.. 2014 M-P Dean: Caftweempanvandpalygm :Site Ed: A2UP03091A STaNlarp SF1880 - 3_;20 - Grp HVVr 70 Strunt,tral Oninar. rylaal(CraS; Strdte NOW-UEagl SOU SUEdqW,. ....... Adjd.s: 200000barlbobeaRoan iSR70) Cly. Ircetardin, stale:; In. Zip: UNS "tiluda. -Eatsara56Z IrFelanatn AnnEed Gnninal., Cullman. jAyad Sandier teal Save INEW J.12)20164A]nuA Leal Media" B,. YALWASH ProjectType: L7001LISDO RFDS Upgraded? Upgraded Template? Standard Cell Site Configuration CoaFi,,v,atb*nTVe: Carildmllon701A_9031 L70GAndausaWorn SWAP M.n.lCmflg"ian(Ant onn41n!qMAIPRUj: Senate . ... ... TpESrTd, "FIS, sbays,. prelinflnuz_ FlinalSeder Count. 3. Design Type: Red nreaeIng TM: Capture Sactor Information MPCS CDMA Design A B C D E F Apler. READ center: -Dppdn 1, C... on. 'Ant.. Merited Sbavolealmn: PCS UMTS Design A B C D E F Antenna RAD Career 4.248 .248 248 Ante... 240 EeEcUlaalml: 1 2 AWS UMTS Design A B C D E F Antenna RAOC.nW,. 1248 :NEt 20 Anterse Mated: .20 95 NO "iddeal run 0 a 0 .2 3 .. .... . ...... . .. ... — L2103 Design A a c D E F :Ant... RAD C..Ia,. V5 iAs us ... ..... .... ...... ...... ... — :Arten.Aahripthe '20 No !a j0 0 sectrical 1111, 1 a* 13 2 L700 Design A B C D E F 'Antenna RAD Cablon BNB 249 243 .8 fivflenpaAaltaotb i20 115 240 ;o .0 a lundKcal till: .6 5 4 Antenna Configuration (Site Level) Antenna ReUse Antenna Model Antenna Cry Antenna and (or) Ports Shared Fxlstlng?IQIY MPCS cow t anarn PCSIATIS Re.w. Geeing 13 CeWax, CMA4mNMS2CS(,S .3 MD AWSUMTS :0 on. eon USE) 1.2100 ;RE,AASIWuE,,IS CrIEIPX- CMA43OEHAIMIIEEE-O L700 AE,ddpv-DBXNHSWSS-AlM Shapavolnt.)2100 TMA(ReLlse existing TMA Model TMA Cry TMA Location TMA]NeydNot Needed) PCs uffir's AWS UMTS E Won L700 -Olpl"erlCombinerCont[guraton—A�B—C— 13 E IF DI'leae, Cry Ni:TIN pteaer Minitit2l: ZI'laaa, Cry 12): . . . CppEbIRndUq,,E.XcrMp,Nft .CombinulDuplaxerQty: Antenna Fiber/ Coax Solution (Site Level) UattICS(Yeadi Y" uaaNSNFIbar&OVPfor Rooftop .. . ..... .... UEraCoaXCa0b(Ye3aN*l7 Y.., Hybrid Gable Configuration (Site Level) Hybrid Cable Type: :Hybrid Cable Length: Hybrid Cable CUT. 3 Hybrid Cable Config(Sector Lovell A S C D K http://natdev.eiig.t-mobile.conVCentralIRFDSIRFDSPrint.asp?Siteid=A2PO309M—F—UG 7/27/2015 RFDS Dafa Configuration Sheet Page 2 of 4 ;HCB rvn betvxan Seelerz (c.e. RooRepl -WaW4ankch.) .. ..... _. ...... . ,HYbndO W LensN 1R1:' ..._ . . .. .. _ .. r COVP Configuration [Sib Level) [coup Type (tA: jLa,COVP._ - .. COUP nIYIIg:1 .. .. coup type PC ; Um. COW coup MY l2F a Coax Configuration A B C D E F :F�ieNnO ewx Oty. '2 12 2 - iFaIsM9OoazSiza: t se : i 518 :Reu a xlsWg near rest TOOA(YenMel) `Ns- - --� - - uNorexcesacoaxlNestommevel itJewC xTYpe_:.... . ,'New Caaa Len9lMlne: !RETH Ava Cables. _RETHomHtun Ceble Len9lh(It} _ __' ., http://natdcv.eng.t-mobile.conilCentral/RFDS/RFDSPrint.asp?Siteid=A2PO309M_F UG 7/27/2015 RFDS Data Configuration Sheet Page 3 of 4 System Module System Module city System Module SystemMotlule System Modules (Site Level) Mode a Type MPCS COMA FCSUMTS -FSMF .i AWE UMTs LIE FWF .1 RF Modules (Site Level) RF Module Type RF Module city(d) RF Module Type(2) RF Module gty(2) MPCS COMA PCSUMTS F%B J AWE UMT9 FRIE 0 L21O0 TFRIG .0. L1OO i FRLB - _ .1 - SectorlBTSRJode-B(Site Level) Sector Count: BTS[Node-S Count: MPCS CDMA PCSUMTS :J 1 AWS UMTS iO �1 Ulm LTOO :0 11 Comments A reMer rmm206 to 2/Easperthe SAC Mbrmawn, roan mmpiebtl by ue. swap ONeWlly quN1 anbmms..rdiy5Oamd tE..B CDMASM WIN A L1nO radws as GB end use 0. k henened N. COMA. etlsltn9 equymeM( FSMFIFRBNFJIFB) less Oren 270, no WA reeWmd. Ow (0 N Wp. Ton ground) 1 FBBA I U1900,,, I FSME I U21OO„ 1 FSMF «I FBBA+i FBBC/UIOO DMA eOeraweepNg O�emOVew) 1 on Oroa� (eaklMO) 0,,,1 F8ME/1R1OO., 1 FEMF s 1 FBBA-I FBDD)Ul 0(eAffiM) itlias. System Sub Module city http://natdev.eng.t-mobile.com/Central/RFDS/RFDSPrint.asp?Siteid=A2P0309M_F_UG 7/27/2015 RFDS Data Configuration Sheet Page 4 of 4 Site: A2PO309M - ConflquraUon Omwing I Drawing (1) Comments: a T AMER bttp:llnatdev.eng.t-iiiobile.comICentraVRFDSIRFDSPrint.asp?Siteid=A2PO309M—F—UG 7/27/2015 Kimle y�>- orn H Upgrade MelroPCS 700 MHA2P0309M GTP HWY 70 Antenna Specifications Find wind areas on proposed antennas to check proposed mount capacity. EquipmentVe:= 6.1 Total number of Appurtenances i:= 0.. EquipmentVe— 1 := 0.. EquipmentVe — 20 Enuip. No. Name Height Width Denth Weight EquipVe0:= "CMA-13DH14/6520/E0-8"* HVe,:= 64.6in WVeo:= 15.9in DVeO Sin WTVe0:= 621bf EquipVel :_ "DBXNH-6565B-A2M"* HVe1 72.7in WVe1 := 11.9in DVe1 := 7.1in WTVe1 := 46.31bf EquipVe2:="FRIG"* HVe2:= 15.24iiWVe2;=18.88inDVe2:=5.98inWTVe2 57.31bf EquipVe3' FRIE * HVe3:= 19.3in WVe3:= 22in DVe3:= 5.21n WTVe3 55.11bf Equipve4:= "FRLB"* HVe4 15.75ii WVe4:= 15.75inDVe4:= 5.9in WTVe4 59.521bf EquipVe5.— FXFB * lives 5.2in We. := 17.6in DVe5 := 15.6in WTVe5 = 55.11bf Area — Fr.:= HVer .•WVe. i Page 1 of 3 Date: 8/7/2015 Designed by: CRM Kimley>),Horn MetroPC5700 MHA2P0309M GTP HWY 70 1 Notes: 1. SectorA is considered to be the maximum loading case scenario. 2. Conservatively assumed no shielding of the RRU's. Only the TMA's are assumed to be shielded in this analysis . 3. The COVP is considered to be on a separate mount. i i s i i { Proposed 13' V-Frame Boom Gate Specifications i Proposed Platform a Connect -It Wireless 13' V-Frame Boon Gate, VF13-XX-96. i I Max Combined Load Weight MaxArea 3 MountO:= "VF13-XX-96" WTVF13:= 6501bf AreaV1713 5600in2 3 t a a i d a Proposed Final Configuration - Per Sector Sector A: s 3 (2) CMA-BDHH/6520/EO-8, (1) DBNXNH-6565B-A2M, (1) FRLB, (1) FRIG, (1) FRIE, (1) FXFB i F 3 i Aream :_ (2Area_P)0 + Area_F l + Area_FZ + Area _P3 + Area_P4 + Area_F5 = 3971.32 •in 3 1 I 1 Weightmm,:= (2WTVe)0+ WTVc,+ WTVe2+ WTVe3+ WTVe4+ WTVeS= 397.3216E —Results - - - 3 - - - WTResut£' AroaResuli P.rea�13>Areamaa 'Pass' ">=a�(" 'Pass"� gi Page 2 of 3 Date:8/7/2015 Designed by: CRM M -f vcm.• ANTENNA ORIFNTATION DIAGRAM Y�' �n ar er xrewmr �>.m.r run umr wdrr xo. wimnmswmm. EMI OI�3 MmCWO�INb of Lio�m 46G ttl crR� NmH FW1 omR� m_IDw iM�dRoO{d mf mOIN� ad fN �K�(� N�tl W W lOuwNfICD rt MrRer. miw y metroPCS FLORIDA, LLO. 100 Y.dY6 m41&VL IMMVIi NOL.W rt. WIIAIW[ M1 Yvu fldER IIS@�L.M`L M FL-5302 FL-860. A2PO309M 25 NOVED3ER 2013 osu®w � I sP uPaun[ I rna env. w+v u¢ rm n r.ur Irnor nMron n.n DETAILS AND TOWER ELEVATION lff�l �NIN dm F 041417163 4 1 NOTES: L ALL STRUCTURAL STEEL SHALL C( D 2. ALL CONNECTIONS SHALL CONFOR ALL BOLTS SHALL BE A325-X; ALL RODS SHALL BE ASTM A36; 3. ALL STRUCTURAL STEEL SHALLB CONNECTIONS WITHIN V16 INCH IT 4. STRUCTURAL STEEL SHALL NOTEE WITHOUT APPROVAL OF THE ENG. 5, ALL WELDING SHALL BE DONE BY COMPLIANCE WITH AWS OIL ALL ALLOWEDBY THE MATERIAL BEINC 6. HOT DIP GALVANIZE ALL STRUCTL AND ABRADED AREAS WITH TWO 7, 00 NOT EXCEED THE FOLLOWING MAX. COMMNED LOAD WEIGHT C MAX COMBINED LOAD FORCE I MAX. COMBINED LOAD AREA A' 7,945 SEWN. MAX. COMBINED LOAD AREA AT 6,910 S0.4N 8. "LOAD AREA" IS LARGEST X-SECT'I S. LOAD RATING DETERMINED IN ACC FLORIDA BUILDING CODE 2010„ A 10. ALL 1/2" FASTENERS MUST BE TI II. ALL 5/8" FASTENERS MUST BE,TI 12 ALL 3/4" FASTENERS MUST BE',1 13, MIN. 2 STIFF ARMS REOD. FOR L( 14. AVERAGE ASSEMBLY WEIGHT G MAX PROJECTED ASSEMBLY ARE. A FRANK AFIDAEW FORE, RE DATE 42561 DC. NO. SEAL 4 3 REVISION STATUS M TO ASTM A36 GRADE AISC MANUAL OF STEEL CONSTRUCTION kS SHOWN ON DRAWING. AS SHOWN ON DRAWING. IRICATED TO FIT AT BOLTED UQCE IME CUT UNDER ANY CIRCUMSTANCES IWS 'CERTIFIEO WELDER AND IN ) SIZES SHALL BE THE MAXIMUM OED WITH 0.30 WIRE WIRE -WELD. )TEEL. TOUCH UP ALL FIELD WELDS 5 OF GALVANIZED PAINT. WEIGHT & AREA LIMITS: 650 LEIS. 2,765 LBS. MPH IV ULTI OR 140 MPH IV ASDk 0PH'.(V ULT) OR 150 MPH IV ASDk 1EA OF ANTENNA. LICE WITH TIA-EIA-222-13-2, S.C.E. 7-10. 562 LBS. 2,711 SO. IN. EPATI L2B9 SO. IN IEPANI .E PROJECTION RV OE9. ExSBPEE@ 3 2 U IE C B IY 3 L 1 G D PPAT tli SPElS/ w IMTS/ASSY full xo zw✓E ioFxlFnxs xa x^ xAT° rmauacs iw�s E T77US SITEHW310 E CONNECT -IT WIRELESS, INC TEOVESTA, FL 33469 USA 156E 744-OUM ENGINEER DATE VF13-xx-96 P.A. FORE,P.E. 0+05-13 13" V-FRAME BOOM GATE A FA FORE,P.E. 04-1343 i1 CAGE CODE DWG No- C L13ENG028 CAO FIE W & JV 13-xx96aw S�T 1 of 13 Rwwm N/C SCALE, N/A 2 1 1 4 i 3 2 1 i Rewow ourvoe nn oesammw are ,rexareo AIL L FTCWER C TOWER i D TOWER TOWER A�— TOWER FACE C C 3 I DETAIL B 7 SCALE 0.032 0 45.6 A B B B� I I I' C - DETAIL Q ORQ SCALE O.VS R R RD rsfcLE PRGaEcnDN i7US HWY °� SUM 3 CONNECT IT WIRELESS, INC A FRANK ANOREW FORE, P.E. DATE 3469 1MY95 A AG.UTIM TEaIESTA. FL SM I'll I> USA f559 744-OSW A 13' V-FRAME ME XBOOM GATE ENGINEER DATE oESIGu BaOlrtm F.A.FORE,P.E. 04-05•13 42561 GC. NO. SEAL vrmm LONIRACT MM CWMCT PRFPrJ� STRUCTURBB EMN3R: F.A.FORE P.E. 04-13-13 gg C CAGE CODE DWG N0: L13EN0028 nWZS= APPROVED BY. JOB Bo: 13ENS028 CAD FLF BARE Jvfl3-M-B5A= SHET: 2 of 13 IREmrk WC SCALE VARIOUS 4 3 T2 j 4 3 2 1 owns n¢ �I ogre Invpnorm TOWERp FT D i 5 R 7 6 0000 OO Oe .I 1 _..0 A ^ D D 7 C D C I I n 11 7 I a s F I �_ , 12 I 12 O ! O E' E Q - O e a D I I ECn0 CALE Ff_f N A -A o2s" DETAIL 13 SCALE 0.375 (M 2 P4 T11Ro ANGLE PRDJECT1aN ""'T E °NE SUT-310 CONNECT -IT WIRELESS, INC A fit ml TEDl1ESTA, FL 33469 AmuUSA 15611 744,0510 VF13-xx-96 ENGINEER DATE FRANK ANDREW FORE PE DATE W 13' V-FRAME BOOM GATE A DEM erc FA FORE,P.E 04-05-13 I worn Cm PREPAM smnvm MOM F.A. FORE P.E 04.13.13 sE CAGE CODE DWO N0 am"s�` 42M C L13ENG028 ru6NSEo APMV Affnovm ar: uc. Aro. SEAT uNoa1 caORAcr .qe NR T.9-AG026 CAD FLE NUE JvRIn-962m 3 Of 13 jHmift N/C Istea VARIOUS 4 I 3 2 1 1 4 3 2 1 PC wRv9 I auxGE umml onre iamavm D o I a TOWER 4 TOWER 4 5 i s 17 c 4 c T2 4 a 4 4 4 4 � 4 4 4 B T3 B SECTION GC 7 SCALE 0500 ITYP 4 PQ I � SECTION D-0 SECTION E-E SCALE 0500 SCALE 0500 THIRD ANGLE PROJECTION TT1� 31 CONNECT -IT WIRELESS, INC TEOUESTA, FL 33488 A 8 AMYOUSA I5511 744-0510 VF13-xx ENGINEER DATE FRAM( ANCREW FORE P.E OATE _ 13" V-FRAME BOOM GATE A F.A. FORE,P.E. 0405.13 u mEa 'ACT�� vAEPAEm TB� F.A. FOREP.E. 0413013 SUE CAGE CODE DWG NO GRAB 42551 C L13ENG028 APrTtOvm BY: LIC. Na SEAL � �� u�otn C0N1BACT - .wB M 13ENG028 cm Jvfl3a REASM N/C MALE VARICUS 4 3T 2 1 4 3 2 1 �E sua ouwe 'a oesmm�w o.re ucxavm O O i 12 TOWER it 3 11 THS FAC TF45 FACE CAN POINT CAN POINT OUT OR IN OUT OR IN 12 12 C .• C SECTION FF SCALE 0.600 i ITYP 9 PLI II 31 7 31 B B O OR O DETAIL SECTION G-6 SCALE 0.100 SCALE 0.500 ITYP 2 PLI TT��pppp ANGLE PRo.lEcnoN 1 1n us IfWY °`� am 10 CONNECT -IT WIRELESS, INC ! TEOUESTA. FL 33469 L A �j ply b yT U3A I563 744-M VF13-xx-96 ENGINEER DATE FRANC ANDREW FORE, PE DATE 13" -FRAME BOOM GATE A DESMN m6NFP.R F.A. FORE P.E 0405-13 1mn m Mmm mN xacr MUCILM SW� FA. FORE.P.E 0413.13 SIZE CAGE CODE OWG NO. Uy: 4256 C L13ENG028 A� L mm mu �RA� - im Nm 13ENG028 CM FLE NAME JvR3-xx-SEasm SIM.. 5 of 13 RENSON WC ISME VARIOUS LTC. NO. 4 3 T 2 1 1 4 3 2 1 nevmwx c OE IEMJMI DAM nw.ovm 0 15 15 IS 15 15 D 19 19 � 19 C 13 C 14 36.000 :. 19 13 19 19 19 19 R 9 DETAO_ 1O RD ANGLE PROJECTION f77 U5 3"`- W ONE SUITE CONNECT -IT WIRELESS, INC A ANALYs3 6 50.NIOtL TEDUESTA, FL 33469 USA I5611 74+0510 VF13-xx-96 ENGINEER DATE DATE FRANK ANDREW FORE, P.E.MINMt 13' V-FRAME BOOM GATP.E. A DESSN FA. FOREP.E 04-05.13 1 UI cuvlRAa ERFrAREO s1RLCTW ES FA. FOREP.E. 0413=13 �g CAGE CODE DWG Na.4Y56, C L13EN0028 ,CRAFT� Y: VC. N0. SEAL D 11 DEAR I. ,qB ND 13ENOOM MOME Nm. .Nf13 .Suw SIEE7. Go of 13 REVI90N, WC jwALE 0500A 4 3 7 2 1 1 4 3 2 I xEv dao auxos xa arc oFsaumwI oAT6 Iamnovm i D D fi i6 16 16 I6 20 20 211 20 20 ICI' p O 13 4 36.000 114 I J J LK B 13 20 ZO 20 20 20 B OEMZO TW. RO ANGLE RIaECnaN m us Rwx ONE CONNECT -IT WIRELESS, INC TEOIIESTA, FL 3309 A .�...—...J� AML,Ms a MUJM 74 USA 1S6p VF13-xx-96 ENGINEER DATE FRANK ANOREW FORE, PE FATE L1'.JI 13' V-FRAME BOOM GATE A DEBGB EMWMt FA FORE P.E 04-05-13 TEPAIED ua0w MWMCT SMLT06ES BNsDM FA FORE,P.E 04.1313 612E CAGE CODE: DWG N0: � C I L13ENG028 1vNU� BY: c42561 NF sEnL MEA CtHIBACT JOB N4 13ENS028 cm R.E NFAE ✓vfi3-m-96AM WET. 7 of 13 IREVSM N/C U„ E Q094/1 4 I. I 3 2 4 3 2 1 C A � I I I I. ill I FRANK ANDREW FORE P.E. DATE 42561 I H1C. N0. SEAL EEWIQS PNA�VEL GIfNAE N6pq ri ix I ANTENNA MASTS zl 5 ANTENNA MASTS NOTE T 3, 4, OR 5 MASTS ARE THE ONLY ALLOWABLE CONFIGURATIONS. 2. ONLY THE CONFIGURATIONS SHOWN ARE ALLOWABLE. 3 MASTS MUST BE SPACED AS SHOWN 4. IT IS PFRMI SIBLE TO MIX MAST PIPE DIAMETERS, BUT NOT LENGTHS. ANTENNA MASTS C A 4 THIRD ANGLE PROJECTION nA , LWOM CaNIRACT IAOER CMEACT "' `LA ""E -3W ONE SUT AWLYSES a 50.VIgY5 TEGUESTA, FL 33469 USA 156I T 4-510 CONNECT-IT WIRELESS, INC VF13-XX-96 13' V-FRAME BOOM GATE ENGINEER DAOTTE !2m ENGIAEtIt FA FOREPE. 1 04-05.13 sNRucnIIrE6 Imo' F.A. FORE,P.E. 04.13-13 sM C I CAGE cane DWG Na L13ENG028 °RAF'� FLFN9i'D APFflOVEG By' J® Nm MG028 CM F E NAnE JV 3- 96a SHEET: 8 of 13 PENSION N/C SCALE, Q048/1 4 3 T 2 1 1 4 r C D A FRANK ANDREW FORE, P.E DATE 425a LIC. NO. see 4 3 SECTION H-H SCALE 0.900 (TYP 4 Pl.) s SECTION " SCALE 0.500 (TYP 10 PLI R 7 C 0 jANGLE PROJECTION "' S I- "�o I -3 ONE CONNECT -IT WIRELESS, INC ANwYgsa TEGUESTAL FL 33469 USA IBM 744-0a0 v SNEER DATE VF13 xx 96 GEAGN FA FORE,P.E o4-05-I3 13' V-FRAME BOOM GATE A 11 mWaNm crow MNMCT s6 MRB ENGNEER FA FORE.P.E 1 04-13-13 SZE CAGE COGS DWG NO: DRAFTS C L13ENG028 co Fu our z i 4 0 C 9 SECTION K-K SCALE 0.500 M?2RJ \\ANGLE PROJECTICN A FRANK AMMEW FORE, PE. DATE 42561 LIC. NOND. SEAL 4 3 2 DETAIL L SECTICN %m SCALE 0500 SCALE 0.500 RYP 2 PLI (M 2 PU u n 9 177 9S HWY ONE - CONNECT -IT WIRELESS, INC TRW -FL R&VS?S 6 SfLBIlOM1S T USA $65 744-OW 9 ° ENGINEER DATE VF13-xx-96 SRN F ° F.A. FORE,PE. 04-05-13 13' V-FRAME BOOM GATE A smucTm Boom FA FORE,P.E. 04-13-13 iFE CAGE cope DwG No- �V ,, C L13ENG028 JOB Na f3EN029 CAB RP Rvx= /Vft3-u-96= SKEET. 10 of 13 RSVL90iY WC S E VARIOUS 3 T 2 1 1 4 10 c 9 a] NGLE PROJECTION A FRANK ANOREW FORE, PE DATE 42M LIC. NONO. SEAL 4 -I ENGNM R DETAAO SCALP 0250 2 1.1 F Rl c 9 °' n5 "N G`� SLATE • CONNECT -IT WIRELESS, INC 3K TEOUESfA, FL. 33469 USA 1561) 744090 A0413-13 VF13-xx-96 P.E. 13' V-FRAME BOOM GATE A P.ESIZI CAGE CODE DWG NO c I L13ENG028 'vf%fnP96emi stE7: n of 13 REVISM N/C V! F VAWOUS 2 1 1 4 3 2 1 awne on o�mermax wx wrnwm 3.500 +I D 0.613 5,000 (623%5 31000 I .120 DETAIL® R4.750 . SCALE 0250 .375 --� F--- O c C OZ7 SCALE LE 0375 16.000 10500 375 LSOO la000 � �— 00 t a00o -� y 6.563 2 R.563 aa6o )711' �.668 0563 IO� 250 14 PLI 3.000 2250 �. DETA2(�D 16000 SCALE 0.375 DETA211 SCALE 0275 PRo EcnoN fJ7 05 IT3 °"� sTA. CONNECT -IT WIRELESS, INC JlW7 L uw.rsss a saulwrx TEDDEsra, a. 33469 o • • e USA 15611 7444MW VF13-xx -96 ENS A A MF DESM ENM FA. FORE PP.E. 04-05.13 FRAM AREW FORE, PF DATE � 13' V-FRAME BOOM GATE WD:R LOMRACT FAEPAAFD 5IPoICiIWES EMNEUt F.A. FORE,P.E 04•13.13 SIZE CASE COOS ON NO: ORAFUM 42561 C L13ENG028 FM.%M AMVE0 0Y: LIC N0. eFEI i MOM COMMCT J0S rya 13EN6026 DO FU RAOE Ivffl-=-SFAam 9FFE 12 of Ti Rkl' m WC SUIE VARIOUS 4 3 T 2 1 1 B A PeYJuo 61MIDE N6 OEYAQ'I�oN O/TE /.GAIGVED I lssooe 25209 105563 L500 i2 PLI J1I�. 1f1 OE63 IM PLI 95.688 12 PLI --.44.3751-- DETAIL N 12 PLI �563 52375 � (4 PU p.�j 12 PLI G + + I I p �.—t3.GGG -{-34300-{ MAIL (2 PLI (2; PLI SCALP 0.125 3250 tm --- - t000 563 52000 CEiAd N SCALE 0250 FVGPU 49.500 I2501flEPl �^— L 3.000 �. U`8 2000 L +} -T7-�.{I 3000 I-- �{� 1 ' [z PLIO63 f-I-Z000 C2 PLI SECTIONLF OETAL SCALE 02SO50 I SCALE 0.188 THRO Ark E PROJECTION "' us "WY ONE SUn2 WYW CONNECT -IT WIRELESS, INC TEOUESTA. FL M469 6 USA 03 74+0510 • VF13-xx -96 I DATE P FRAM( ANOAEW FORE. PE. GATE V FRAME BOOM GATE 9ESM ENMEM FA.. FOR RE 0+05.13 UM eae18ae7 I PREPARED slRUCTUR 6 BUM F.A. FORE 0413.13 c� CAPE CAGE CODE; OWD N0: 42561 C L13E VG028 APPROM BY. 11G SEAL ,EDRAFrSM .pa M 13ENG028 CAD Jvfrj. SHEET 13 of 13 6Evauaz we p6wkVAPoWS� 4 II 11 3 T 2 1 1 C c B A Kim[epMorn Carrier Designation: MetroPCS 700 MHz Upgrade Carrier Site Number: A2P0309M Carrier Site Name: GTP HWY 70 Site Data: 2000 Okeechobee Road, Fort Pierce, FL 34945 St. Lucie County 13e 320 J.Z115 1 0 115 130 150 / I a�" ' 140 a 140 rw. �. `-`�'e«j n �f � AHW V 150 fltan St. Lucie 140 County 160 i Notes' 150 1. values are noeinal design 3-eac.mi gust Xe I wind speeds in miles per hour (mis) at 33 .. It (10n) above ground for Exposure C cab egary �.. sV ne 2. Linear interpolation between contepr6 160 is permitted. f' 3. islands and coastal areas outside the - lest contour shall use the lost wind speed 170 a mw co.taur of the coaztal are.. I 'i 4. Mauntstuous terrain, gorges, me" F b„ promontories, and special wind regions we shall be etmnined for unusual wind cendl- tions. 5. wind speeds correspond to approximately y, i a 9X probability of exceedance in N yews (Anneal Exceedance Probability a 0.09143, - _ _ - -l— M3I n7ea years). _— Vnominal — Vultimate X NrO,6 151 mph x0 6 = 117 mph 2014 Florida Building Code— Figure 1609A Briley horno < 1920 WekiVd Wayr,Swt q00;- st Pale -Beach FL'.334'1 1 r561 845 O96