Loading...
HomeMy WebLinkAboutPLANS 2r ' IivA%I ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR OONi��1NCE REVIEWED BY MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE 5�TQv(-T I FI ITEM QTY. DESCRIPTION 0 2 12" HINGE EXTRUSION O2 2 12" HINGE EXTRUSION Q 2 1 1/2"X 1" "F" RETAINER ® 4 1 1/2"X 1" "F" RETAINER Q 2 1 Z" HINGE RETAINER © 10 HINGE BRACKET O7 4 2" X 3" X 16" ALUMINUM ANGLE 1 2" X 4" X 16" STEEL TUBE O9 2 5" X 5" X6' STEEL SQUARE TUBE 10 1 2" X 4" X 16" STEEL TUBE 11 2 12" X 12" X 4' STEEL BASE PLATE 1© 1 1 2' X 1 2' X 8' STEEL ANGLE 13 1 2" X 4" X 8" STEEL CAP 14 1 z'EYEBOLT 15 1 REPLACEMENT BOLT FOR EYEBOLT 16 4 4" X 4" X 8GUSSET 17 4 2" X 2" X6" ALUMINUM ANGLE 18 4 2"X2"X6ALUMINUM ANGLE 19 4 PROP ROD BRACKET WELDED TO "F" RETAINER @33 16' ©0 4 PROP ROD BRACKET WELDED TO CABINET @ 37 a' Date: 8-21-15 Sign Model: Page ��EBBSSCCONSign roiup Drawn by: DCH J.M.S. TEMPLATE MUST BE USED TO SET THREADED RODS INTO CONCRETE TEKSTAR 58, 32x112 1 OF 3 IWStxraao-m-tee ° Drawing #: Sketch M Customer #: Customer Name: Customer Address: tewartsigns m.ha,�n�r.� TEK-20mm-R-32x112 860�09—� 1106146 THECROSSING CHURCH 5200OLEANDER L34982AVENUE COMMUNITY CHURCH FORT PIECRCE, FL 34982-4063 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 7Y,ESE .S AND ALL PROPOSED WORK, ARE SUBJECT TO ANY CORRECTIONS REQUIRE:) BY FIELC !,�.SPECTGRS THAT MAY BE NECESSARY IN OS,02P TO COMPLY WITH ALL APPLICABLE CODES. JOHN FRANCIS BARRETT, PE 8259 BAR T ON FARMS BLVD. SARASOTA, FL 34240 P.E. NO.44816 w a a 'v X z 0 w z a w M 0 1-- z W ❑ 0 z ❑ som0so ,t, Lucie County CONCEALED FASTENERS OR ATTACHMENT. ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD "LEFT VIEW" TEKSCREWS TEKSTAR TEKSCREWS BILL OF MATERIALS ITEM QTY. DESCRIPTION LENGTH O2 2" X 2" x $" Aluminum Angles 1' O2 4 7"Aluminum bracket 11.25" .3 20 Tek Screws #10 x 1" ® 2 Tek Screws #12 x 14' O5 2 2" X 3" x 16" Aluminum Angles 7 8" " FRONT VIEW" TEKSC1REWS TEKSCREWS �IJ 2x1I4" TEKSCREWS— #10; 1" 4 #1 \ 2 Req1" 'd #10 x 4 Req'd per angle 4 Req'd per angle 32X112 TEKSTAR #10 x 1" 4 Req'd TEKSCREWS 3 4 Req'd0 x 4 Req'd per "Z" TEKSCREWS 3 #10 x 1" q 4 Req'd per "X 9" 2$" —I^ —lix ' T' Mtg Bracket "' Aluminum "RIGHT VIEW" 6 y r� n i K"I"�i PIL-Ai't8 r wit rs G LEKvi P11Vi Ei t j [ .t]` ML ➢���. r3F �lY�'�Y�f A F- B�16��p+ a y� yypyp S,9fE !?i ���0., IRIBell CUSTOMER #1106146 THE CROSSING COMMUNITY CHURCH Date: 8-21-15 - sign moaer. Page EBBSCO Sign GroupiDrawn by: DCH J.M.S. TEMPLATE MUST BE USED TO SET THREADED RODS INTO CONCRETE TEKSTAR 58, 32x112 2 OF 3 vs v�uEwa�Lm a - - wuamnrma ssl�erPu Drawing #: Sketch #: Customer #: Customer Name: Customer Address: ��tewartsigns AVENUE TEK-20mm-R-32x112 860109-1 1106146 COMMUNITY CHURCH FORT P ECRCEDFL34982-4063 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY N ORDER TO COMPLY WITH ALL APPUCAELE CODES. JOHN FRA"!CSS BARRETT• PE 8259 B.qR i ON F R S BL4 D. SARASOTAr— P.E. NO. 4 of W Q D. x 00 z 0 w z z a W m 0 H w z w 0 z ❑ T I 9 FOOTER - FRONT VIEW NOT TO SCALE THREADED ROD EMBED IN CONCRETE FOOTER BOTTOM EBSCO Sign Group mtcwrvoanB;aulEns vxla ar FRR�190E4flns sfewatNsi F�.•I•w"� FACE DETAIL NOT TO SCALE FOOTER - SIDE VIEW NOT TO SCALE BOTTOM FIGURE B EMBED IN CONCRETE FOOTER FACE DETAIL I-12 A. HEADER PANEL SECTION, 1}" THERMO-FORMED UV �1Y- RESISTANT MAKROLON SL POLYCAR13ONATE DECORATION PER STEWART SIGNS ARTWORK. DECORATED WITH 3M HIGH 1 1/4' DIAMETER T-F PERFOMANCE TRANSLUCENT VINYL. HOLES 77 B. TEKSTAR LED, MOUNTED INSIDE SEAMLESS, 12' 9' 3' HOLES FOR 9' 12" SINGLE PIECE, FACE OF MAKROLON SL POLYCARBONATE ELECTRICAL &DATA FOOTER DETAIL O OUTLETS O 1. 12"X12"X3/4" STEEL BASE PLATES, 2 REQUIRED 2� 2. 1"X30" ANCHOR ROD, 8 REQUIRED TAPE THE EXPOSED TOP OF THE THREADED RODS BASE PLATE DETAIL FOR PROTECTION AGAINST CONCRETE. NOT TO SCALE - 3. #5 REBAR OR BETTER, TIED AT EACH JOINT. SUPPLIED 6Y THE CUSTOMER 4. CONDUIT, SUPPLIED BY THE CUSTOMER THREADED ROD NOTES NUT • DESIGNED FACTOR MEETS OR EXCEEDS 150 MPH WIND LOAD AT EXPOSURE C. WASHER BASE -SIGN • 3,000 PSI CONCRETE - LESS THAN 4.17 CUBIC YARDS NECESSARY PLATE BASE s .LEG PLATE ELECTRICAL INFO • (1) 20 AMP CIRCUIT, 120 VOLTS, MAX DRAW 9.52 AMPS 7 712' - • UL LISTED - E50724 • SIGNS SHALL BE GROUNDED BY CONNECTION TO THE 3 1/2" - EQUIPMENT GROUNDING CONDUCTOR OF THE SUPPLY - BRANCH CIRCUIT. • LED COMMUNICATION METHOD: SHORT RANGE WIRELESS c CONCRETE a FOOTING d'a .WASHER d ' ° ONCEALED F STENERS OR ATTACHMENTS THESE PLANS AND ALL FRGFGSEU 41C?•� < LEVELING NUT ARE SUBJECT 70 ANY CO^r.RECTIOi.'B a ° ARE THE ESPONSIBILITY OF THE REQUIRED BY FIELD IPISPECTORS -LLHAT a ° ° MAY BE NECESSARY 1N ORDER IQ a CONT ACTOR OF RECORD COMPLY WITH,gLLAPPLICASLE Q.ODIM, Li-dI iLE�lii.���U- u 1 i 4 fi f{�� 01gK.5- j Pk; Date: 8-21-15 Drawn by: DCH J.M.S. TEMPLATE MUST BE USED TO SET THREADED RODS INTO CONCRETE DRAWING DESIGNED TO BE PRINTED ON 8 -2'X14" PAPER ign Model: Page TEKSTAR 58, 32x112 3 OF 3 TEK-20mm-R-32x112 I 860109-1 1106146 I THE CROSSING COMMUNITY CHURCH JOHN FRANCIS BARRETT, PE 8259 BAR' ON FARMS BLVD. SARASOTA, FL 34240 P.E. NO.44816 5200 OLEANDER AVENUE FORT PIECRCE, FL 34982-40�