Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL1 FILE Force Entgineering & Testing Inc. 19530 Ramblewood Drly Hu blc l'X 77338 SCANNEL) Product Evaluation Report BY WHIRLWIND STEEL BUILDINGS, INC St. Lucie Collar 26 Ga. Super Span X Wall Panel over open framing Florida Product Approval # FL 17702.3 Florida Building Code 2014 Per Rule.61G20.3 Method: 2 —B Category: Structural Components Subcategory: Structural Wall Compliance Method:61G20-3.005(2)(B) NON HVHZ Product Manufacturer: Whirlwind Steel Buildings, Inc. 8234 Hansen Road Houston, TX 77075 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Locke Bowden, P.E., FL#49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1-3 E'F 4rQ�Vl CEAlS0 No. 49 STATE OF O Ri ar A�nm imps . FL# 17702.3 04/30/2015 Force Engineecing & Testing Inc. 19530 Rwnblewood Drive Homble;IX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the. Florida Building Code 2014, Sections 1709.2. Product Description: Super Span X Wall Panel, 26 Ga. Steel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, panel material shall comply with Florida Building Code 2014 Section 1405.2. Yield Strength: Min. 80.0 ksi Panel Dimension(s): Thickness: 0.0185" min. Width: 36" coverage Rib Height: 1-1/4" major rib at 12" O.C. Panel Fastener: #12-14 x 1-1/4" Ultimate HWH SD with sealing washing or approved equal at 12"- 12"-12" fastener pattern. Panel side laps fastened together w/ Y,14 x 7/8" Ultimate HWH SD w/ sealing washer at 20" O.C. Corrosion Resistance: Per Florida Building Code 2014. Substrate Description: Design Pressures: Min.16 Ga. Steel Framing. Framing must be designed in accordance w/ Florida Building Code 2014. Table "A" Maximum Design Pressure: -46.9 psf -135.3 psf t52.1 psf Fastener Pattern: 12"-12"-3Y 12"-12"-12" 12"-12"-12" Fastener Spacing: 5'-W O.C. 2'-W O.C. 5'-0" O.C. 'Design Pressure includes a Safety Factor =2.0. %%c E , E'I? E lg��//37 No. 449, �•�• STATE OF 4, �F AlOR�4,: FIL# 17702.3 04/30/2015 y Force Engineenng & Testing Inc. 195M Ramble od Drive AumblgTX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2014, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards:- The product described herein has demonstrated compliance with: • ASTM E 1592-05 Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference. Reference Data: 1. ASTM E 1592-05 Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 14-0286T-14A-C. 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering &Testing, Inc. (FBC Organization # ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturers recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2014 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2014 Chapter 22 for steel, and Chapter 16 for structural loading. E'E No. *0Q A•?� STATE OF : a ��F FLORI9A•�+`"� •xmlil§rnt►?t FL# 17702.3 04/30/2015 "y � 9 ` e .. .� s C w C 26 GA. SUPER SPAN X PANEL FASTENER PATTERN 12" � 1 � 12" 12" 1 1 --� #12-14 x 1 1/4" ULTIMATE HWH w/ SEALER WASHER 3/4" FASTENER OFFSET 3/4" FROM RIB 1/4-14 X 7/8" ULTIMATE LAP SCREW ® 20" O.C. i l41gea1FlaAEp - O.OA; alum — ++�„uueeeedae �. ENScr No. 44923 S 3. "0 : STATE OF �• i �. , 00 ,v APR 2 8 2015 Q�QOPuC.1 ,Aep kuvNL A k -F'x i-6A_ta R FL# 17702.3 Force EngineVesting Inc. 19530 Ramblenvod Drive HumhLe,TC 17339 Product Evaluation Report WHIRLWIND STEEL BUILDINGS, INC 26 Ga. Super Span X Wall panel over open framing Florida Product Approval # FL 17702.3 Florida Building Code 2014 Per Rule 61G20-3 Method: 2 —B Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(B) NON HVHZ Product Manufacturer: Whirlwind Steel Buildings, Inc. 8234 Hansen Road Houston, TX 77075 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Locke Bowden, P.E., FL #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1-3 SCANNtL, BY • LuCiiP Cnantl 1119111111, `�� F1•C E• E• iy lle Na. 4492s STATE GF : ce 0 0 P' l 1) -4V .LXGS,� llll O R L I l it 04/30/2015 Force Engineenng - Testing Inc. 19530 Ratnblc.vood Im,e Hnmble.TX 77339 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1709.2. Product Description: Super Span X Wall Panel, 26 Ga. Steel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, panel material shall comply with Florida Building Code 2014 Section 1405.2. Yield Strength: Min. 80.0 ksi Panel Dimension(s): Thickness: 0.0185"min. Width: 36" coverage Rib Height: 1-1/4" major rib at 12" O.C. Panel Fastener: i112-14 x 1-114" Ultimate HWH SD with sealing washing or approved equal at 12". 12"-12" fastener pattern. Panel side laps fastened together w/'/,-14 x 7/8" Ultimate HWH SD w/ sealing washer at 20" O.C. Corrosion Resistance: Per Florida Building Code 2014. Substrate Description: Min. 16 Ga. Steel Framing. Framing must be designed in accordance w/ Florida Building Code 2014. Design Pressures: Table ^A" Maximum Design Pressure: -06.9 psf -135.3 psf +52.1 psf Fastener Pattern: 12"-12"-12" 12"-12"-12" 12"-12"-12" Fastener Spacing: 5'-0" O.C. 2'-0- O.C. 5'-0" O.C. FL# 17702.3 uesign rremure mcmaes a 5arety a�=2.0. ttttllltllrI'rI �v.• b F 4� STATE OF :or :P. A4 0 R I I1 imrc is 'r •JqAL •NG ��, '',,Orlllll0 %`%' 04/30/2015 Force Engineering & Testing Inc. I9530 Rambimvood Drive Hum61c,TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2014, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ASTM E 1592-05 Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference. Reference Data: 1. ASTM E 1592-05 Force Engineering & Testing, Inc (FBC Organization #TST-5328) Report No. 14-0286T-14A-C. 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2014 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2014 Chapter 22 for steel, and Chapter 16 for structural loading. NtCrE rk . ", , c. ! : NO.4W2s� (%j�i�21n.(Qy✓ . STATE OF P DUAL FL#17702.3rirrrt1 A`, 04/30/2015 26 GA. SUPER SPAN X PANEL FASTENER PATTERN 12" 1.E 12" 12" 1 1 ` #12-14 x 1 1/4" ULTIMATE HWH w/ SEALER WASHER 3/4" FASTENER OFFSET 3/4" FROM RIB 1/4-14 X 7/8" ULTIMATE LAP SCREW 0 20" O.C. ftwotFlodda oaena $peeaaaeaeaaenaa NGP— E. j 1✓rasa No.44923 `.. 1R' • 'Gi • 7ti e a STATE OF .•fie p•A- P•4: APR 202015