HomeMy WebLinkAboutSTRUCTURAL CALCULATIONSNational Consulting Engineers, Inc. Certificate of Authorization # 8755 7255 SW 126th Street Pinecrest, FL 33156 Phone: (305) 321-7041 Fax: (305)238-2362 Structural Calculations for Garage Door Framing Plan At New Metal Stair and Railing New Roll -up Doors and Doors Project Number NC15-207 September 28, 2015 s(;Aw ED BY St. Lt cie COU>ntY Total Number ofPages:37 Not Including This Page and the Table of Content Page To the best of my knowledge, I performed, reviewed and checked all the structural calculations including computer generated calculations New v Structural Design And FEM Analysis Certificate of Authorization #8755 7255 S.W. 126th Street Pinecrest, FL 33156 Phone: (305) 321-7041 Fax (305) 238-2362 Mohamed W Fahmy, PhD, PE# 54794 DL (psf) LL (psf) OW of Channel (#/ft) TL (psf) Horizontal Span L (ft) Vertical (ft) u (ft) Tributary Width (ft) N (#/ft) = Tributary Width'TL M (in.K) = w'L"U8'12/1000 Allowable Stress (ksi) Section I (in4) S (in) f (ksi) = M/S (ksi) (in) Materials Allowable Stress (ksi) Thickness (in) Riser Height (in) S (in) Consider Riser (Vertical Part) only Span (ft) Case 1: Uniform LL (100 psf) M1 (in.#) Case 2: Live of load of 300 # M2 (in.#) f (ksi) = Max.(M1, M2)/S 15.000 /.. 100 15.000 115.000 15.500 10.500 18.722 1.500 98.578 I } ASTM A-36 24.000 L MC12x14.3 76.300 12.700 7.762 OK 29000 0.23422718 Ratio = LID Steel ASTM A-36 24.000 0.188 2.000 0.125 3.000 1350.000 2902.5 23.220 OK 959.1532 OK 1300 # OR W -- - -- .. L V INC. New Structural Design And FEM Analysis Certificate of Authorization #8755 7255 SW 126 Street Pinecrest, FL. 33156 Phone: (305) 321-7041 Fax: (305) 238-2362 Stress (Ksi) Sx (in3) Sy (in3) Span (in) P (#) M = P*U2 (in.#) W (#/ft) M=W*L*U1218 (in.#) (ksi) = Mmax/Smin (ksi) = Mmax/Smin Material: Section: Sy (in3) Allowable Stress (Ksi) L (in) Spacing (in) w (#/ft) = 25*Spacing/12 M (in.#) = W*L*U12*8 f (ksi) = Mmax/Sy Sy (in3) Allowable Stress (Ksi) L (in) w (#/ft) = 25*Lpicket/2/12 M=W*L*L/12/8 (in.#) f (ksi) = My/Sy S1 (in3) Allowable Stress (Ksi) Maximum Post Spacing (ft) P (#p= Max(200#,50*Post Spacing) H (in) M (in.#) = P*H1 f = M/S (ksi) 812015 Steel ASTM A53 Grade B 24 0 1 1/4" schedule 40 0.235 0.235 48 200 2400.00 Case 1 50 1200.00 Case 2 10.21 Status 10.21 Status M]A T 200# L L I OR W I L I Steel ASTM A53 Grade B � 1 1/4" schedule 40 25 W 0.041 24 48 I 4.5 9.38 225.00 5.49 Status OK Steel ASTM A-500 Grade B ¢ 1 1/4" schedule 40 0.235 W 24 48 50.00 L 1200.00 5.11 Status OK P Steel ASTM A-500 Grade B ¢ 1 1/4" schedule 80 0.291 28.14 POST 4 = 200 40.5 Post is welded above stringer 8100.00 27.84 Status OK 1UH 11UNAL CONSULTING ENGINEERS, INC. Project:D and D Welding New North Shop Structural Design And FEM Analysis Certificate of Authorization #8755 7255 S.W. 126th Street SUBJECT: Wind Cacluations and Design for Doors SHEET N": Pinecrest, FL. 33156 3 Phone: (305) 321-7041 Fax (305) 238-2362 JOB NO: DATE: DESIGNED BY: Mohamed W Fahmy, PhD, PE # 54794 NC15-207 9/27/2015 Mohamed Code: FBC 2010 Wind Calculations: ASCE7-10 Risk Category 2 Exposure C Wind Speed (mph) 170 Average Roof Height of the Building (h) (ft) 20 (Kz) from Table 30.3-1 0.94 Kd 1 Kzt 1 qz = 0.00256"Kz.Kn.Kd-V2 (lb/ft2) (30.3-1) 69.54 Working qz = qz'.6 41.73 Length of the Building (ft) 91.00 Width of the Building (ft) 100.00 a (ft) 8.00 Width (ft) 3 Averahge Height of Door (ft) 7 Tribuary Area Use (ft) 21.00 Gcp -ve -1.05 Ccpi +ve 0.95 Ccpi 0.18 -ve wind pressure (pst) -51.32 +ve wind pressure (psf) 47.15 Use Door with NOA # 15.0123.01 from DAB with Assembly 7 Allowable +ve pressure (psf) 65 Allowable -ve pressure (psf) -53.50 Width (ft) 12 Averahge Height of Door (ft) 16 Tribuary Area Use (ft?) 192.00 Gcp -ve -0.88 Ccpi +ve 0.80 Ccpi 0_18 -ve wind pressure (psf) -44.23 +ve wind pressure (psf) 40.89 Use Door with NOA # 14.0814.06 from DAB with Assembly 7 Allowable +ve pressure (psf) 60 Allowable -ve pressure (psf) -60.00 Width (ft) Averahge Height of Door (ft) Tribuary Area Use (ft) Gcp'-ve Ccpi +ve wind pressure (pst) wind pressure (psf) Wall Panel with FL 17702.3 6.666666667 Use Width = Height/3 20 133.33 -0.88 0.80 0.18 -44.23 40.89 iat+t IUIVHL GUNJULTING ENGINEERS, INC. Project:D and D Welding New North Shop Structural Design And FEM Analysis Certificate of Authorization #8755 7255 S.W. 126th Street SUBJECT: Design of Door SHEET N': Pinecrest, FL. 33156 4 Phone: (305) 321-7041 Fax: (305) 238-2362 JOB NO: DATE: DESIGNED BY: Mohamed W Fahmy, PhD, PE # 54794 NC15-207 9/27/2015 Mohamed With Fastening Spacing at 5' feet Vertically and 12" Horizontalivl '"'a`v""• Steel ASTM A-36 Section: C8x11.5 ` Sx (in3) 8.14 Allowable Stress (Ksi) 24 Maximum Span (in) 180 Tributray Width (ft) 6.00 q(#/ft) = p*Dw/2 307.95 q L M (in.#) = q*L*L/12/8 103931.47 f (ksi) = M/Sx 12.77 Status OK Maximum Shear on the Bottom (#) 2309.59 Use (2) If 5/8" HUS HILTI By inspection, bolts are adequate. Check of Steel Jamb to Roll -Up Door Material: Steel ASTM A-500 Grade B Section: HSS 8"x4"x1/4" Sx (in3) 11.9 Sy (in3) 7.9 Allowable Stress (Ksi) 30.82 Width (ft) 22 Tension (#/it) 510 Shear(#/ft) 2281 Maximum Span (in) 192 M (in.#) = Tension*L*L/12/8 195840.00 f (ksi) = M/Sx 16.46 Status OK The shear Force is transmitted to the Puffin Purline Spacing (ft) 5.000 Force per Purlin = Shear * Pruline Spacing ( 11405 Purline Area (in2) 0.84 Compressive Stress (ksi) 13.58 Status OK Welding Thickness 0.1875 Effective welding (in) 0.09 Welding Length (in) g Welding Filler EXX 70 Allowable Stress (Ksi) 21 Allowable Force by Weld (#) 15120 Status OK