Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISIONS 1
16eASIi "&-�o' mw70)27 Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive SCANNED Ft. Pierce, FL 34982 (772)631-5709 BY St. Lucie County Revisions from County Comments May 31, 2016 St. Lucie County Plan Review Building Department For Pierce, FL Re: PSL Plaza (Shonnine Center) — Revisions i Permit #:�— ,.y,` /S/G- o/27 The following changes are in response to Plan Review comments by Joe Cicio and have been clouded and dated. Revisions: 1. See A4 for correct 1 hour fire rated drive thru ceiling 2014 FBC reference; 2, See (3) copies of Gut sheets for exhaust fan; If you have any questions, please contact me at a ' e. 'OF-Ft:oR�ov Sincerely, y' ADVANCED ARCHITECTURE V. • ; ING LLC qA-26002573 Raymond Chladny, STFREn nc` ✓"` B.arch.Sc., March, AIA MAAA, MFAID, NCARB Florida License No. AA26002573 Upblast Ventilator, Wheel 11 In, 115V DAYTONIZoro #: G1156285IMfr #: 5DVP0 Technical Specifications •O Assembled/Unassembled: Assembled CFM ® 1.250-In. SP: -/-/- CFM H 0.750-In. SP: -/-/- CFM N 2.000-In. SP: - CFM ® 1.000-In. SP: -/-/- Drive Type: Direct -Drive Speed Controllable: Yes CFM ® 2.75-In. SP: - CFM'® 2.500-In. SP: - CFM ® 1.500-In. SP: -/-/- Wheel Material: Aluminum RPM: 1050/1300/1650 Includes: NEMA,1 Junction Box Adj. 6 3/8"H Roof Curb Stock No.: 4C453 Fixed UL 762 Kitchen Roof Curb Stock No.: 4HX54 Standards:'UL/cUL 705, AMCA Sound and Air CFM M 0.125-In. SP: 247/343/431 JUN - 3 REUD getrt,41+ �G slo -(2c7-7 i��Kx�a�k' o � -•z. i--Gd Hz: 60 CFM 8 2.250-In. SP: - CFM @ 0.875-In. SP: -/-/- Phase: 1 CFM 8 1.75-In. SP: - Max. Inlet Temp.: 130 Degrees Motor Voltage: 115 Housing Material: Spun Aluminum Item: Upblast Ventilator with Motor Speed Control: 48C172 Number of Speeds: 3 Requires: Roof Curb For New Installation Adj. 12 3/8"H Roof Curb Stock No.: 2ZV82 Recommended 8 In. Fixed Curb Item No.: 4HX38 Adj. UL,762 Kitchen Roof Curb Stock No.: 4HX61 CFM ® 0.000-In. SP: 325/403/480 CFM ® 0:250-In. SP: 133/272/376 Recommended Damper Stock No.: 3TZ50 ;°'Shaft D a Wheel End. 1/2" Wheel Dia.: 11' Dimension D: 11-1/2' Dimension A: 19' CFM ® 0.500-In. SP:-/-/235 Max. Operating Amps: 1.48/1.82/2.44 Max BHP '0 02/0 03/0 05� A' �. Speed Controllable: Yes Dimension B: 21' Sones @ 0.500-In. SP @ 5 Ft.:-/-/7.6 Dimension C: 13-3/8' Zoro Number: G1156285 9=1/2 o Upblast Ventilator with Motor, Drive Type Direct -Drive, Number of Speeds 3, Wheel Dia. 11 In., CFM @ 0.000-In. SP 325/403/480, Sones @ 0. 125-In. SP @ 5 Ft. 3.6/5.4/7. 3, Assembled, Motor Voltage 115, 1 Phase, 60 Hz, Max. Operating Amps 1.48/1. 82/2. 44, Motor HP 1/20, Max. BHP 0.02/0.03/0.05, RPM 1050/1300/1550, Base Length 19 In., Base Height 1-3/4 In., Overall Dia. 21 In., Base Width 19 In., Shaft Dia. Wheel End 1/2 In., Overall Height 13-3/8 In., Max. Inlet Temp. 130 Degrees