Comp nent Performance Method for Commercial Buildings
Form 40OB-97
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
FLA/COM-97 Version 2.2
PROJECT NAME_A T X FORMS
ADDRESS: _FT. PIERCE
OWNER:
AGENT:
—F, T X FORMS
PERMITTING OFFICE:
_ST. LUCIE COUNTY
CLIMATE ZONE: 6
PERMIT NO: _00-000
JURISDICTION NO:_661000
BUILDING TYPE: _Business (Office)
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Finished Building
CONDITIONED FLOOR AREA: _15000 NUMBER OF ZONES: 1
MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5
COMPLIANCE CALCULATION:
METHOD B
DESIGN
CRITERIA
RESULT
------
-----------------
ENVELOPE PERFORMANCE
------
37.59
--------
71.57
PASSES
OTHER ENVELOPE REQUIREMENTS
PASSES
LIGHTING
INTERIOR LIGHTING
27000.00
27000.00
PASSES
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
10.00
10.00
PASSES
HEATING EQUIPMENT
1. Et
1.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS
1. Unconditioned Space
6.00
4.20
PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
PIPING INSULATION REQUIREMENTS
----------------------------------------------------------------------------
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE:
I hereby certify that this building is
in compliance with the Florida Energy
Efficiency Code.
OWNER/AGENT:
DATE:
I hereby ce
Energy Effi
ARCHITECT :
MECHANICAL•
PLUMBING
ELECTRICAL:
LIGHTING
(*) Signatu
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
Section 553:908, Florida Statutes.
BUILDING OFFICIAL:
DATE:
rL7_Lyl'1 LctaL UuC aYaU u, ucoiyu i
ciency Code.
SYSTEM DESIGNER
ure
+.,. .. ..yam+..+...... ..�.... �.... .�..�.......
_
REGISTRATION/STATE
kt
is required where Florida law
quires design to be performed
by registered design professionals. Typed names and registration numbers may
be used where all relevant information is contained on signed/sealed plans.
- BUILDING ENVELOPE SYSTEMS COMPLIANCE
CHECK
4A1------- GLAZING --ZONE 1------------------------------------------------
v-
Elevation Type U SC VLT Shading Area(Sgft)
------------------------
---- ---- ---- -------------- ----------
North Commercial 1.31 .01 0 None 568
.
South Commercial 1.31 .01 0 None 432
East Commercial 1.31 .01 0 None 128
West Commercial 1.31 .01 0 None 56
Total Glass_ Area in_ Zone- L = 1184
Total Glass Area = 1184
402------- WALLS --ZONE 1-----------------------=------------------------
---
Elevation Type U Insul R Gross(Sgft)
----------------------------------------- ----- ------- -----------
North 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 4 1350
South 811CMU/3/4"ISO Stwn 24"oc/5/8"Gyp 0.151 4 1350
East 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 4 900
West 811CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 900
Total Wall.Area in Zone 1 = 4500
Total Gross Wall Area = 4500
403.------DOORS--ZONE 1------------------------------------------------
---
Elevation Type U Area(Sgft)
--------------------------------------------------- -----
North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 21
Total Door Area in Zone 1 = 21
Total Door Area = 21
404------- ROOFS --ZONE 1------------------------------------------------
---
Type Color U Insul R Area(Sgft)
------------------------------------ ------ ----------------------
Shngl/1/2"WD Deck/WD Trus.s/9" B Medium 0.027 30 15000
Total Roof Area in Zone 1 = 15000
Total Roof Area = 15000
405------- FLOORS -ZONE 1------------------------------------------------
---
Type Insul R Area(Sgft)
-----------------------------------------------------------------
S1ab on Grade/Uninsulated 0 15000
Total Floor Area in Zone 1 = 15000
Total Floor Area = 15000
406.------INFILTRATION --------------------------------------------------
---
Infiltration Criteria in 406.1.ABCD have been met. ICHECK
MECHANICAL SYSTEMS
CHECK
------------------------------------------------------------ ---- ---
HVAC load sizing has been performed. (407.1.ABCD)
407.------COOLING SYSTEMS----------------------------------------------- ---
Type No Efficiency IPLV Tons
---------------------------- ------------- -------------------
1. Split System 4 10 0 5.00
408.------HEATING SYSTEMS----------------------------------------------- ---
Type No Efficiency BTU/hr
------------------------ ----------- ------
1. Electric Resistance 4 1 31420
409------- VENTILATION --------------------------------------------------- ---
ICHECK
Ventilation Criteria in 409.1.ABCD have been met.
'410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- ---
CHECK
--------------------------------------------------------- --- ---
Duct sizing and design have been performed. (410.1.ABCD)
AHU Type Duct Location R-value
--------------------------------------------------------------
1. Packaged Constant Volume Unconditioned Space 6
CHECK
--- - --------------------------- ----- -
Testing and balancing will be performed. (410.1.ABCD)
411.-----PUMPS-AND PIPING -ZONE ----------------------------------------- ---
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411.-----PUMPS AND PIPING -ZONE 1--------------------------------------- ---
Type R-value/in Diameter Thickness
------------------------ ---------- ---------------
412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- ---
Type Efficiency StandbyLoss InputRate Gallons
ELECTRICAL SYSTEMS
CHECK
413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- ---
Metering criteria in 413.1.ABCD have been met.
414------ MOTORS --------------------------------------------------- ----- ---
Motor efficiencies in 414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- ---
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
---------- ----------------- ----------------- --- ------ ----------
Reading, T 1 On/Off 34 27000 15000
Total Watts for Zone 1 = 27000
Total Area for Zone 1 = 15000
Total Watts = 27000
Total Area = '15000
CHECK
Lighting criteria in 415.1.A13CD have been met_
-
----------------------------------------------------------------- ----- ---
16.. Operation/maintenance manual will be provided -to owner.. (102...1)
----------------------------------------------------------------------------
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
BUILDING ENVELOPE COMPONENT PERFORMANCE
WALL ORIENTATION WEIGHTED AVER.
N NE E SE S SW W NW DESIGN CRITERIA
GL
SC
PF
VLT
Uof
W Uo
HC
IP
HEAT
COOL
SUM
1350-
568
0.010
0.00
0.00
1.310
0.15
21.00
3
1.618
9.627
11.245
900
128
0.010
0.00
0.00
1.310
0.15
21.00
3
0.424
7.073
7.497
1350
432
0.010
0.00
0.00
1.310
0.15
21.00
3
L O A D S
1.039
11.133
12.173
******** PASSES *-******
900
0.26
0.267-
56
WWR
WWR
0.010
0.01
0.500
0.00
0.00
0.00
0.00
0.00
N/A
1.310
1.31
1.150
0.15
0.15
0.371
21.00
21.00
1
3
3
N/A
TOT
0.279
3.360>
3.262
6.394
34.228<
68.307
6.673
37.588<
71.569
OTHER ENVELOPE REQUIREMENTS
MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN CRITERIA
Percentage of Roof Area in Skylights 0.000 = 0.0000
1 MAXIMUM ALLOWABLE Uo:
Roof 0.027 < 0.0868
******** PASSES *******
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office.)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
LIGHTING SYSTEM PERFORMANCE
BUILDING DESIGN':
Interior Lighting Power 27000 W 1.80 W/Gross ft2
Exterior Lighting Power 0 W
INTERIOR LIGHTING CRITERIA:
Space No.
Type Area Clg Ht Spaces AF
I -
UPD PB LPB Total LPB
26 15000.0 9.0 1 ][ 1.00 1.8U 1.80 27000 27000
Unit Power Density 1.80 W/Gross ft2
Interior Lighting Power Allowance 27000 W
******** PASSES ********
EXTERIOR LIGHTING CRITERIA:
AREA AREA AREA OR ALLOWANCE
CODE DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
**** Not 'Applicable ****
LIGHTING SYSTEM CONTROL REQUIREMENTS:
SPACE NO.
NO. DESCRIPTION AREA TASKS TYPE 1
TOTAL EQUIVALENT
CONTROLS CONTROL POINTS
NO. TYPE 2 NO. DESIGN CRITERIA
26 Reading, T 15000.0 1 IIOn/Off 34I 011 34 > 18
******** PASSES ********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
HVAC SYSTEM REQUIREMENTS:
Cooling System
.. Type
Measure
#1 #2
Minim.
#1
Minim.
#2
System
Eff.#1
System
Eff.#2
Result
for #1
Result
for #2
Split Sys.
SEER
10.00
0.00
10.00
0.00
PASSES
Heating System
Measure
Minimum Req.
Efficiency
Result
Ele. Resis.
Et
1.00
N/A
******** PASSES ********
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS:
Zone # Duct Location Minimum R-Value Design R-Value Result
1. Unconditioned Space 4.20 6.00 PASSES
******** PASSES ********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
WATER HEATING SYSTEM REQUIREMENTS
System Measure Minimum Maximum Design I Design Result
Type l fiF / Et SL I EF / Et I SL
**** Not Applicable ****
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thickness(in)
System Type O.D.(in) Minimum Req. Design Result
**** Not Applicable ****
PAUL WELCH INC.
Mechanical - Electrical - Civil - Engineering
1984 S.W. Blihnore SL #114
Port St. Lucie, FL 34984
Phone (407) 785-9888
FAX (407) 785-9933
AP4 4 2000
data:
sheet I of
EM
MANUAL "N"
C WORK SHEET
ROOM: AREA:
(S o u o
JOB:
Q Tx
ZONE:
i
WALL ...............
4540 SF x
09
S WAIL............
45¢O SF X
9,34
32II4-
C WALL ...............
l200 SF x
WALL ...............
IZUd SF x
4 =
1 $ 7Z
--hi-GLASS .. ............
SPIS SF x
41 =
Z 345ti
S GLASS...............
3 Z SF x
41 =
I rI'l (I-
5 GLASs ..............
13 o SF x
GLASS..............
(PC SF x
ROOF..... ..............
15000 SF x
2,2 =
32600
LIGHTS• .................
30000 W X
3.41 =
(D Z 30 0
PEOPLE...................
INPIL (62-89)...........
Z000 C:E3MX
S+ =
109000
sutr Iota-1 =
5- duct losses — 1 241 o
TOTAL. = 4. Z S IG Q
u52 C2) -Stogy tit A-% fit) - 2 tbv, kK;{ ,
C4}- 4 to., uV%,+s.
Component Performance Method for Commercial Buildings Form 400B-97
ENERGY EFFICIENCY CODE
FOR BUILDING
CONSTRUCTION
Florida Department
of Community
Affairs
FLA/COM-97
Version 2.2
PROJECT
NAME -A T X FORMS
PERMITTING OFFICE:
ADDRESS:
_FT. PIERCE
_ST. LUCIE COUNTY
CLIMATE ZONE: _6
OWNER:
_A T X FORMS
PERMIT NO: _00-000
AGENT:
JURISDICTION-NO:_661000-
BUILDING TYPE: _Business (Office)
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Finished Building
CONDITIONED FLOOR AREA: _15000 NUMBER OF ZONES: 1
MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5
COMPLIANCE CALCULATION:
METHOD B
-----------------
ENVELOPE PERFORMANCE
OTHER ENVELOPE REQUIREMENTS
LIGHTING
INTERIOR LIGHTING
LIGHTING CONTROL REQUIREMENTS
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
HEATING EQUIPMENT
1. Et
DESIGN
37.59
27000'.00
AIR DISTRIBUTION SYSTEM INSULATION
1. Unconditioned Space
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
PIPING INSULATION REQUIREMENTS
10.00
1.00
REQUIREMENTS
6.00
CRITERIA RESULT
71.57 PASSES
PASSES
27000.00 PASSES
PASSES
10.00 PASSES
N/A
4.20 PASSES
----------------------------------------------------------------------------
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE:
I hereby certify that this building is
in compliance with the Florida Energy
Efficiency Code.
OWNER/AGENT:
DATE:
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
Section 553:908, Florida Statutes.
BUILDING OFFICIAL:
DATE: _
I hereby certify(*) that the system design is in
Energy Efficiency Code.
SYSTEM DESIGNER
ARCHITECT :
MECHANICAL:
PLUMBING
ELECTRICAL:
LIGHTING
(*) Si at
compliance with the Florida
REGISTRATION/STATE
u - - 7.a
by registered design professionals. Typed n mes; and registration numbers may
be used where all relevant information is cc tained on signed/sealed plans.
by registered design professionals. Typed n mes; and registration numbers may
be used where all relevant information is cc tained on signed/sealed plans.
BUILDING ENVELOPE SYSTEMS COMPLIANCE
CHECK
401------- GLAZING --ZONE 1------------------------------------------------
v-
Elevation Type U SC VLT Shading Area(Sgft)
------------------------ ---- ---- ---- -------------- ----------
North Commercial 1.31 .01 0 None 568
South Commercial 1.31 .01 0 None 432
East Commercial 1.31 .01 0 None 128
West Commercial 1.31 .01 0 None 56
Total Glass Area -in Zone l = 1184
Total Glass Area = 1184
402.------WALLS--ZONE 1------------------------------------------------
---
Elevation Type U Insul R Gross(Sgft)
----------------------------------------- ----- ------- -----------
North 811CMU/3/4"ISO Btwn 24"oc/5/8"Gyp G.151 4 1350
South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 1350
East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 900
West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4 900
Total Wall Area in Zone 1 = 4500
Total Gross Wall Area = 4500
403.------DOORS--ZONE 1------------------------------------------------
---
Elevation Type U Area(Sgft)
--------------------------------------------------- ----- ----------
North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 21
Total Door Area in Zone 1 = 21
Total Door Area = 21
404.------ROOFS--ZONE 1------------------------------------------------
---
"Type Color U Insul R Area(Sgft)
------------------------------------ ------ ----------------------
.Shngl/1/2"WD Deck/WD Truss/9" B Medium 0.027 30 15000
Total Roof Area in Zone 1 = 15000
Total Roof Area = 15000
405.------FLOORS-ZONE 1-----------------------------------------------=
---
Type Insul R Area(Sgft)
----------------------------------------------------------
-------
Slab on Grade/Uninsulated 0 15000
Total Floor Area in Zone 1 = 15000
Total Floor Area = 15000
406.------INFILTRATION --------------------------------------------------
---
Infiltration Criteria in 406.1.ABCD have been met. ICHECK
MECHANICAL SYSTEMS
CHECK
---- ----- ------- ---- ----- ----------- -------------------------- ---- ---
HVAC load sizing has been performed. (407.1.ABCD)
407.------COOLING SYSTEMS----------------------------------------------- ---
Type No Efficiency IPLV Tons
------=--------------------- ------------- -------------------
1. Split System 4 10 0 5.00
408.------HEATING SYSTEMS----------------------------------------------- ---
Type No Efficiency BTU/hr
-------------------------------- ---------------------------
1. Electric Resistance 4 1 31420
409.------VENTILATION --------------------------------------------------- ---
I CHECK
Ventilation Criteria in 409.1.ABCD have been met.
410------- AIR DISTRIBUTION SYSTEM---------------------------------------- ---
CHECK
-------------------------------------------------------- ----- ---
Duct sizing and design have been performed. (410.1.ABCD)
AHU Type Duct Location R-value
----------------------------------------------------------------
1. Packaged Constant Volume Unconditioned Space 6
--------- CHECK
--------------------------------------------- --- ---
Testing and balancing will be performed. (410.2-ABCD)
411 ------ PUMPS AND PIPING -ZONE ------------------------------------------ ---
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411.-----PUMPS AND PIPING -ZONE 1--------------------------------------- ---
Type R-value/in Diameter Thickness
---------------------------------------------------
412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- ---
- Type Efficiency StandbyLoss InputRate Gallons
ELECTRICAL SYSTEMS
CHECK
413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- ---
Metering criteria in 413.1.ABCD have been met.
414.-----MOTORS --------------------------------------------------- ----- ---
Motor efficiencies in 414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- ---
Space Type No Control Type 1 No Control Type 2 No Watts Area (Sgft)
---------- ----------------- ----------------- --- ------ ----------
Reading, T 1 On/Off 34 27000 15000
Total Watts for Zone 1 = 27000
Total Area for Zone 1 = 15000
Total Watts = 27000
Total Area = '15000
CHECK
Lighting criteria in 415.1.ABCD have been met.
------------------------------------------------------------------ ----- -
1,6. Operation/maintenance manual will be provided- to owner..(102...1)
PROJECT TITLE
A T X
FORMS
BUILDING TYPE
Business (Office)
BUILDING LOCATION
ST. LUCIE COUNTY
BUILDING AREA(ft2):
15000
BUILDING ENVELOPE COMPONENT
PERFORMANCE
WALL
ORIENTATION
WEIGHTED
AVER.
N NE
E
SE S SW
W
NW DESIGN CRITERIA
WALL
1350
900
1350
900
0.26
0.267
GL
568
128
432
56
WWR
WWR
SC
0.010
0.010
0.010
0.010
0.01
0.500
PF
0.00
0.00
0.00
0.00
0.00
0.00
VLT
0.00
0.00
0.00
0.00
0.00
N/A
Uof
1.310
1.310
1.310
1.310
1.31
1.150
W Uo
0.15
0.15
0.15
0.15
0.15
0.371
HCJ
21.00
21.00
21.00
21.00
21.00
1
IP
3
3
3
3
3
N/A
L O A D S
TOT
HEAT
1.618
0.424
1.039
0.279
3.360>'
3.262
COOL
9.627
7.073
11.133
6.394
34.2284
68.307
SUM
11.245
7.497
12.173
6.673
37.588<
71.569
******** PASSES *******
OTHER ENVELOPE REQUIREMENTS
MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN CRITERIA
Percentage of Roof Area in Skylights 0.000 0.0000
MAXIMUM ALLOWABLE Uo:
Roof 0.027 < 0.0868
i
******** PASSES *******
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
LIGHTING SYSTEM PERFORMANCE
BUILDING DESIGN-:
Interior Lighting Power
27000
W 1.80 W/Gross ft2
Exterior Lighting Power
0
W
INTERIOR LIGHTING CRITERIA:
Space No.
Type Area Clg Ht Spaces AF
I
UPD
PB LPB Total LPB
26 15000.0 9.0 1 1.00
1.80
1.80 27000 27000
Unit Power Density
1.80 W/Gross ft2
Interior Lighting Power Allowance
27000
W
******** PASSES ********
EXTERIOR LIGHTING CRITERIA:
AREA AREA AREA OR ALLOWANCE
CODE DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
**** Not Applicable ****
LIGHTING SYSTEM CONTROL REQUIREMENTS:
TOTAL EQUIVALENT
SPACE NO. CONTROLS CONTROL POINTS
NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA
26 Reading, T 15000.0 1 On/Off -34 0 34 > 18
******** PASSES ********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
HVAC SYSTEM REQUIREMENTS:
Cooling System
..• Type
Measure
#1 #2
Minim.
#1
Minim.
#2
System
Eff.#1
System
Eff.#2
Result
for #1
Result
for #2
Split Sys.
SEER
10.00
0.00
10.00
0.00
PASSES
Heating System
Measure
Minimum Req.
Efficiency
Result
Ele. Resis.
Et
1.00
N/A
******** PASSES ********
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS:
Zone # Duct Location Minimum R-Value Design R-Value Result
1. Unconditioned Space 4.20 6.00 PASSES
******** PASSES ********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
WATER HEATING SYSTEM REQUIREMENTS
System Measure Minimum I Maximum I Design I Design Result
Type I ] EF / Et -I SL I EF / Et SL
**** Not Applicable ****
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thickness(in)
System Type O.D.(in) Minimum Req. Design Result
**** Not Applicable ****
PAUL WELCH INC.
V Mechanical • Electrical • civil • Engineering
1984 S.W. Bilhnore SL #114
Port SL Lucie, FL 34984
Phone (407) 785-9888
FAX (407) 785-9933
date • h r R 4 2000
sheet I Of
ROOM: �l.D%. AREA' l 5 0 0 o JOB • 6'Tx
ZONE: 1
WALL ...............
4540
sF
x
'2,,4$ _
([e,7 oI
S WALL ...............
4S4o
SF
x
�l•Sl. _.
3-2A 4
G WALL ...............
(SOO
SF
x
59SZ
WALL ...............
1200
sF
x."
4,S6 =
9 9j ri2
GLASS.. ................
572
sF
x
41 =
2 340-
S GLASS ...............
4 3 Z
sF
x
41 =
1 rl rl 1 Z
GLASS ..............
136
SF
x
Q I =
1 a'5 a
Lk) GLASS ..............
U o
SF
x
q I
5 4 G 0
ROOF............... ...
15060
SF
X.
3 �1000
LIGHTS .................
30000 W
x
3.41
10 Z 30 O
PEOPLE...................
IpO
x
Sao �:
SOOoo
INFM (62-89) ...........
2000
cfm: x
54 =
1043 000
Suit Total 4156 $l 9
5t duct. losses 1 24f7 o
TOTAL. _ 4. Q u IG
use (2) ' Stogy fA Vb4�5 IANt
(6) - 4 to., NYC,+s.
VB/L0/VV lY. YU lAA JV1YV11 JVV
Y
CMJYL\ 4l\Vll\uv�\
FRASER ENGINEERING AND TESTING, INC.
1504 INDUSTRIAL74d STREET • FORT PIERCE • FLORIDA' 14W
VERO BEACH (561) %7-6167 FORT PIERCE (5611 /61-75M STUART (561)263-7711 FT. PIERCE 1-0M2319W I
L Report
P\e�'v f' Zoo4o;v i of
7305 c&vAvAtm ai eA-i cff-
V- n 5 9wy Zw us4Izl ►qrK
CLTE.iT; Carlton Paving, Inc.
CONTRACTOR; Client
DENSITY OF SOIL IN PLACE
ASTM D2922
SITE: ATX. Kings Hwy. Industrial Park.
Foundation Fill
DRIe: 5i2/00
-
L1ENSfry
TEST
NU.
393
DATE
LOCATION
51101STURE-DENSITY
RELATIONSHIP
IN PUCE
DRY
DENSITY
PERCENT
CO1(PACTIO-4
�•TESTED
ELEATION
TEST
NO.
)LL%.
DRYU-r-
92/00 S.)A. Comer
0- 11
592
126.3
124.5
98.6
594
Corner
0 - 1'
124.3
98.4
-
595
Center
0 - 1'
133.8
98.0
596
N.E. Comer
0 - I
124.0
98.2
597
S.E. Comer
0 - 1'
124.8
98.8
ALL ELEVATIONS BELOW SLAB GRADE
Copies: Client-2
MAY,
Respcctfully submillcd,
D)I FRASER
AND TESTING, INC.
Alexander H. Frascr/P:E_fla ivo"76t78
IPUOLI.CWWORKS
ST_ LUC I,. COUI111Y, FL ^ :/�.`• ._
GEOIEQOOC4 EH AEER FpONDA7IGN PNESTGATQIS GGHCRETE, SOL. ANDASPHLT TESTJIG
Ub/ZO/UU 14:4U YAA 0014DIfOU0 rNADZA nAulilnnn
FRASER ENGINEERING AND TESTING, INC.
J] INMS IXw. Jim's I xkr' I h()K I f1LKCh,kL1)R1UA J4%46
VACT PFRCE 1561).61-75a6 STUART 1561)2&�7711 Fr PIERCE t�06231.901t
Report
of
MOISTURE DENSITY RELATIONSHIP
ASTM 0-1557
CLIENT: Carlton paving
CO'N-F*ACTOR. Client
SITE; ATX Kings Hwy, Industnal Park
Foundation Fill
P.0 F.
on 'Acigh
Too I Tma
NO.
mlhw s--1
592 I A Composite
GWTECJNfa1 E�
13
mWillum
-rDn'Wjphj
oplm=
momW %
9.8
DATE: 5/2/00
126.3 Brox%n. 5lightlysiltv slighdy clayey,
Ifine sand
Respectfully submitted,
FRASFR ENGfNEERING AND TESTLNG, INC.
..... .....
.Mcxander H. Frai P�.E.. F larida'.Rcg--No. 16)78
PUBLIC WORKS DEPARTMENT
MEMORANDUM
TO: Kathy Cicio, Building Division
FROM: Charles A. Cangianelli, Building & Zoning Manager
SUBJECT: ATX Forms
As -Built Denied
DATE: April 21, 2000
***DENIED***
******************************************************************
Engineering has reviewed the paving and drainage for this project and does not accept
the installation for completion at this time.
The submittal is insufficient in the following manner:
1. A Driveway Permit is required by Road & Bridge Division.
If I can be of further assistance to you in this matter, please let me know.
CAG/sra
CC: County Attorney
Don West, P.E., County Engineer
Velcon
RK Davis
t PAIIL WIP4I,CH INC.
Maehenkel • Eloodcel • CWU • Englnaedng
1984 S.W. @iRmore St. i114
Pon SL Lucie, FL 3084
Phone (561) 785-9868
FAX (661) 785-9933
May 10, 2000
St. Lucie County Building Department
2300 Virginia Ave.
Ft. Pierce, FL 34982
Attn: Charles A. Cangianelli
Re: ATX
Permit No. Zoo4OZ9l
To Whom It May Concern:
Please be advised that the central corridor for the above
referenced project will be 1 hour fire rated with 20
minute, Class C fire doors.
Revised plans will he provided.
Thank you for your attention to this matter.
submitted by:
INC.
P.E.
u
Component Performance Method for Commercial Buildings Form 400B-97
ENERGY EFFICIENCY CODE
FOR BUILDING
CONSTRUCTION
Florida Department
of Community
Affairs
FLA/COM-97
Version 2.2
PROJECT
NAME_A T X FORMS
PERMITTING OFFICE:
ADDRESS:
_FT. PIERCE
_ST. LUCIE COUNTY
CLIMATE ZONE: 6
OWNER:
--A T X FORMS
PERMIT NO: _00-000
AGENT:
JURISDICTION-NO:_661000
BUILDING TYPE: mousiness (Office)
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Finished Building
-CONDITIONED FLOOR AREA: _15000 NUMBER OF ZONES: 1
MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5
COMPLIANCE CALCULATION:
METHOD B
DESIGN
CRITERIA
RESULT
------
-----------------
ENVELOPE PERFORMANCE
------
37.59
--------
71.57
PASSES
•. OTHER ENVELOPE REQUIREMENTS
PASSES
LIGHTING
.INTERIOR LIGHTING
27000.00
27000.00
PASSES
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
10.00
10.00
PASSES
HEATING EQUIPMENT
1. Et
1.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS
1. Unconditioned Space
6.00
4.20
PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
PIPING INSULATION REQUIREMENTS
------------------------------------
---------------------------------------
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE:
I hereby certify that this building is
in compliance with the Florida Energy
Efficiency Code.
OWNER/AGENT:
DATE:
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
Section 553:908, Florida Statutes.
BUILDING OFFICIAL:
DATE:
I hereby certify(*) that the system design is in compliance with the Florida
Energy Efficiency Code.
ARCHITECT
MECHANICAL:
PLUMBING
ELECTRICAL:
LIGHTING u (*) Signatu
SYSTEM DESIGNER
REGISTRATION/STATE
PAUL WELCH IN
AP
re is required where Florida
requires design to be performed
by registered design professionals. Type mes and registration numbers may
be used where all relevant information is ntained on signed/sealed plans.
BUILDING ENVELOPE SYSTEMS
COMPLIANCE
CHECK
401.------GLAZING--ZONE 1------------------------------------------------ v-
Elevation Type U SC VLT Shading
----
Area(Sgft)
------------------------ ---- ---- --------------
North Commercial 1.31 .01 0 None
----------
568
South Commercial 1.31 .01 0 None
432
East Commercial 1.31 .01 0 None
128
West Commercial 1.31 .01 0 None
56
Total Glass Area. in_ Zone. 1 =
1184.
Total Glass Area =
1184
402-------- WALLS --ZONE 1-----------------------=------------------------
---
Elevation Type U Insul R
Gross(Sgft)
----------------------------------------- ----- -------
North 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4
-----------
1350
South 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 4
1350
East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4
900
West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4
900
Total Wall Area in Zone 1 =
4500
Total Gross Wall Area =
4500
403------- DOORS --ZONE 1------------------------------------------------
---
Elevation Type U
---------
Area(Sgft)
------------------------------------------ -----
North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60
----------
21
Total Door Area in Zone 1 =
21
Total Door Area =
21
404.------ROOFS--ZONE 1------------------------------------------------
---
Type Color U InSul R
Area(Sgft)
------------------------------------ ------ ------------
Shngl/1/2"WD Deck/WD Truss/9" B Medium 0.027 30
----------
15000
Total Roof Area in Zone 1 =
15000
Total Roof Area =
15000
405.------FLOORS-ZONE 1------------------------------------------------
---
Type Insul R
Area(Sgft)
-------------------------------------------------------
Slab on Grade/Uninsulated 0
----------
15000
Total Floor Area in Zone 1 =
15000
Total Floor Area =
15000
406------- INFILTRATION --------------------------------------------------
---
CHECK
Infiltration Criteria in 406.1.ABCD have been met.
MECHANICAL SYSTEMS
CHECK
-------- ----- ------- ---- ----- ----------- -
------------------------- ---
HVAC load -sizing has been performed. (407.1.ABCD)
407-------- COOLING SYSTEMS -------------------------------------- =-------- ---
Type No Efficiency IPLV Tons
---------------------------- ------------- ----------- -------
'I. Split System 4 10 0 5.00
408.------HEATING SYSTEMS----------------------------------------------- ---
Type No Efficiency BTU/hr
-------------------------------- ---------------------------
1. Electric Resistance 4 1 31420
409.------VENTILATION --------------------------------------------------- ---
IVentilation Criteria in 409.1.ABCD have been met. CHECK
410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- ---
CHECK
------------------------------------------------------ ---- ---
Duct sizing and design have been performed. (410.1.ABCD)
AHU Type Duct Location R-value
----------------------------------------------------------------
1. Packaged Constant Volume Unconditioned Space 6
CHECK
------------ - ---------------------------------------- ---
Testing and balancing will be performed. (410.1.ABCD)
411.-----PUMPS AND PIPING -ZONE ----------------------------------------- ---
.Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411------ PUMPS AND PIPING -ZONE 1--------------------------------------- ---
Type R-value/in Diameter Thickness
----------------------------------------------------
41.2.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- ---
Type Efficiency StandbyLoss InputRate Gallons
ELECTRICAL SYSTEMS
CHECK
413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- ---
-Metering criteria in 413.1.ABCD have been met.
414.-----MOTORS --------------------------------------------------- ----- ---
Motor efficiencies in 414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- ---
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
---------- ----------------- ----------------- --- ------ ----------
Reading, T 1 On/Off 34 27000 15000
Total Watts for Zone 1 = 27000
Total Area for Zone 1 = 15000
Total Watts = 27000
Total Area = 15000
CHECK
Lighting criteria in 415.1.ABCD have been met.
------------------------------------------------------------------ ----- ---
i6. Operation/maintenance manual will be provided to owner...(102...1)
----------------------------------------------------------------------------
PROJECT TITLE
A T X
FORMS
BUILDING TYPE
Business (Office)
BUILDING LOCATION
ST. LUCIE COUNTY
BUILDING AREA(ft2):
15000
BUILDING ENVELOPE COMPONENT
PERFORMANCE
WALL
ORIENTATION
WEIGHTED
AVER.
N NE
E
SE S SW
W
NW DESIGN CRITERIA
WALL
1350
900
1350
900
0.26
0.267
GL
568
128
432
56
WWR
WWR
Sc
0.010
0.010
0.010
0.010
0.01
0.500
PF
0.00
0.00
0.00
0.00
0.00
0.00
VLT
0.00
0.00
0.00
0.00
0.00
N/A
Uof
1.310
1.310
1.310
1.310
1.31
1.150
W Uo
0.15
0.15
0.15
0.15
0.15
0.371
He
21.00
21.00
21.00
21.00
21.00
1
IP
3
3
3
3
3
N/A
L 0 A D S
TOT
HEAT
1.618
0.424
1.039
0.279
3.360>'
3.262
COOL
9.627
7.073
11.133
6.394
34.228<
68.307
SUM
11.245
7.497
12.173
6.673
37.588<
71.569
******** PASSES *******
OTHER ENVELOPE REQUIREMENTS
MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN CRITERIA
Percentage of Roof Area in Skylights 0.000 = 0.0000
MAXIMUM ALLOWABLE Uo:
Roof 0.027 < 0.0868
n
******** PASSES *******
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
LIGHTING SYSTEM PERFORMANCE
BUILDING DESIGN":
Interior Lighting Power 27000 W 1.80 W/Gross ft2
Exterior Lighting Power 0 W
INTERIOR LIGHTING CRITERIA:
Space No.
Type Area Clg Ht Spaces AF UPD PB LPB Total LPB
26 15000.0 9.0 EIF
n 1.00 1.80 1.80 27000 27000
Unit Power Density 1.80 W/Gross ft2
Interior Lighting Power Allowance 27000 W
******** PASSES ********
EXTERIOR LIGHTING CRITERIA:
AREA AREA AREA OR ALLOWANCE
CODE DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
**** Not Applicable ****-
LIGHTING SYSTEM CONTROL
REQUIREMENTS:
TOTAL EQUIVALENT
SPACE
NO.
CONTROLS
CONTROL POINTS
NO. DESCRIPTION AREA
TASKS TYPE 1
NO. TYPE 2
NO. .DESIGN CRITERIA
26 Reading, T 15000.0
1
On/Off
341
0
34 > 18
******** PASSES
********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(£t2): 15000
HVAC SYSTEM REQUIREMENTS:
Cooling System
..' Type
Measure
#1 #2
Minim.
#1
Minim.
#2
System
Eff.#1
System
Eff.#2
Result
for #1
Result
for #2
Split Sys.
SEER
10.00
0.00
10.00
0.00
PASSES
Heating System
Measure
Minimum Req.
Efficiency
Result
Ele. Resis.
Et
1.00
N/A
******** PASSES ********
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS:
Zone # Duct Location Minimum R-Value Design R-Value Result
1. Unconditioned Space 4.20 6.00 PASSES
******** PASSES ********
PROJECT TITLE A T X FORMS
BUILDING TYPE Business (Office)
BUILDING LOCATION : ST. LUCIE COUNTY
BUILDING AREA(ft2): 15000
WATER HEATING SYSTEM REQUIREMENTS
System lMeasurel Minimum l Maximum I Design I Design (Result
Type L J EF / Et I SL I EF / Et I SL
**** Not Applicable ****
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thickness(in)
System Type O.D.(in) Minimum Req. Design Result
**** Not Applicable ****
PAUL WELCH INC.
Mechanical • Electrical . Civil • Engineering
1984 S.W. BBhnore St. #114
Port St Lucie, FL 34984
Phone (407) 785-9888
FAX (407) 785-9933
h R 4 2000
I
date.
sheet of
MANUAL "NIT
H4AC WORK SHEET
ROOM: �t_DK. AREA;
(S o u o
JOB.
�TK
ZONE:
1
WALL...............
454o sip x
4Zo1
S wALI+...............
45+0 SF x
9•3L
a
3 A 4
G WALL ...............
(Lo o SF x
4,114
1 WALL ...............
/ Z0O SF x '
"6
►-� GLASS ................
5'72 SF x
1
=
2 345ti
S GLASS ...............
4 $Z sF x
41
=
1 rl `1 I z
' GLASS ..............
13 o SP x
4 I
=
II � 3 0
GLASS ..............
00 Sr x
q 14
G O
ROOF...... .............
15000 SF x
LIGHTS.................
0000 W x
3.41
=
1 0 Z 30 O
PEOPLE..................
10,0 x
$ao
=:
rjd 000
INFIL (62-89) ...........
7006 cfm x
54
=
I O9 000
4.1 S6 _,
Sub Total
St duct losses
=
—
120 o
of=
use (2)-s-tov. Hwt-kz
(6). 4 to., IAV%t+s.
ST. LUCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
2300 VIRGINIA AVENUE, ROOM 201
•.�` FT. PIERCE, FL. 34982-5652
407-462-1553
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all
applications for building permit involving the construction of now residence (single or mufti-famiy), residential addition, any accessory
structure requiring a building permit and any nonresidential structure. This Certification shall not apply to interior renovations (provided
that no structural walla, columns or other similar component is being affected) and certain other minor building_ permits. For further
assistance, please contact the Budding inspection Office at 462-1553 or 462-2172
PROJECT NAME �%j. G <:::.:DFFICE:�iISE"ONLY ..:
NEI
STREET ADDRESS C-CMVAtMI" Cl'( e— .PR NUMBER
O(• 3 PERMrT NUMBER
OCCR TYPE
CST. TYPE
CERTIFICATION STATEMENT:
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS
HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL
ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND
FORCES SPECIFIED BY CURRENT CODE PROVISIONS.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (Mr check or ownp ete the aDDroor®te box)
1...' BUILDING CODE EDITION USED rrEAm lqqZ SBCCI ASCE 7-98 OTHER (SPECIFY)
2 BUILDING DESIGN IS (afar OUE) ENCLOSED X PARTIALLY ENCLOSED OPEN BUILDING
S. BUILDING HEIGHT: O FT 4. WIND SPEED USED IN BUILDING DESIGN:: o MPH
6. WIND EXPOSURE CLASSIFICATION (wt lD owomm TABLES IN waLDING CODE memFED IN UNs at): C-
e. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: ._5 PSF
7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE 35' PSF
e. IMPORTANCEMSE FACTOR (OBTAIN FROM BUILDING CODE).
B. LOADS: FLOOR U� PSF ROOFIDEAD: 15'— PSF ROOFAJVE ZO PSF-
10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE Or= crq YES NO _ If NO, why? (aearll.
'11. IS A CONTINUOUS LOAD PATH PROVIDED taEm oW YES NO_ 1( NO, why? (attach
eaplanatlon)
12 ARE COMPONENT AND CLADDING DETAILS PROVIDED (aEac GrE1 YES NO _ If NO. why? (attach
1�. MINIMUM SOIL BEARING PRESSURE 71.5700 PSF
AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLU WITH THIS
CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIE
NAME. • PAI11 WE�lrf�Q�— CERTIFICATION NO: - AP Z 2000
DESIGN FI1984 S.W. BILTMORE ST. S DATE: APR T i Pnnn I ERE]
f T-
34984 eomoao
4
ST. LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
2400 Rhode Island Ave Telephone (561)-462-2312
Fort Pierce, Florida 34950 Fax:: (561)-462-2323
TYPE OF PERMIT
( X ) New Construction ( ) Tenant Improvement ( ) Addition ( ) Renovation/alteration ( ) Shell Only
Jurisdiction: St Lucie County
Occupancy: OFFICE BUILDING
Address: Commercial Circle
Contractor: R. K.
Davis
Contractors address:
P. O. Box 186
ArchitecVEngineer:
Paul Welch, Inc
Building owner:
Steve & Glynn Willett
Occupancy type:
Business
Gross sq. ft.
14,776 sq ft
Occupant load:
Construction type ( NFPA-220)
Type:
F.P.B.: B-00-118
Building Dept: 20040291
Number of stories: 1
Phone # 561461-8335
City: Ft Pierce, FL Zip: 34954
Phone: 561-785-9888
Review date: 4-27-00
Automatic sprinklers:
Net sq ft:
Based on: 100 sq ft per person
SBCCI: Type: V
NOTE
1. All revisions must be in compliance before the final inspection, or so noted.
2. The Fire Marshal required 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Failed inspections require payment of fee prior to scheduling of any further inspections.
5. Permit fees are required to be paid in full prior to any inspections.
6. A copy of the required revision/s have been transmitted to the Architect ( ) Contractor ( ).
REVISIONS REQUIRED
1. Exit access corridors are required to be one hour rated with 20 minute door and jamb
assemblies, if the occupancy is subject to thirty or more persons and not protected by
an automatic fire sprinkler system. SBC 1997 704.2.4 and Table 704.2.4
2. Automatic fan shut down is required for all HVAC systems. Duct type smoke detectors
are required. See attached for further requirements.
t
3. Provide portable fire protection. One 2A-10BC rated extinguisher every 75' of travel
Q distance.
4. Penetrations through rated assemblies shall be by proper UL Design.
Reviewed By:
Tony Liento
Date: April 27, 2000
t�
FIRE MARSHAL'S
OFFICE v
r- o
w a
x x
F9FDISjR���
St. Lucie County
Fire District
(561)462-2312 • FAX (561)462-2323
AUTOMATIC FAN SHUT DOWN REQUIREMENTS
FOR AIR HANDLING SYSTEMS.
2400 Rhode Island Ave.
Fort Pierce, FL 34950
The requirements for automatic fan shut down in air handling systems are the
requirements of the Standard Mechanical Code, 1997 Edition, Chapter 4, Section 406,
and the National Fire Protection Association, Life Safety Code NFPA 101.
In determining which code to comply with, the following information is necessary.
1. A/C units make up a system and is referred to in the codes as an air
handling system
2. The NFPA Life Safety Code, Occupancy Chapters 8 through 31 references
Heating, Ventilation, and air Conditioning and shall comply with Section
101-7-2 of the Life Safety Code.
3. Section 101-7-2 requires air conditioning, heating, ventilating ductwork,
and related equipment to be installed in accordance with NFPA 90A,
Standard For The Installation Of Air Conditioning and Ventilation
Systems, or NFPA 90B, Standard For The Installation of Warm Air
Heating and Air Conditioning Systems.
4. NFPA 90A. Scope: This standard applies to all systems for the movement
of environmental air in structures that:
a. Serves spaces over 25,000 cubic feet in total volume, or
b. Serve buildings of Type III, IV, and V construction over three
stories in height, regardless of volume. The construction types
indicated are in accordance with NFPA 220.
5. NFPA 90A. For the purpose of this standard, a space is considered as the
entire building or a portion thereof separated from other portions of the
building by fire resistance rated construction and whose environmental air
does not mix with that of any other space. For spaces not exceeding
25,000 cubic feet in volume, reference the Standard Mechanical Code,
Chapter 4, Section 406.
6. Spaces not exceeding 25,000 cubic feet in total volume shall be in
accordance with the Standard Mechanical Code, 1997 Edition.
7. Automatic fan shut down requirements. NFPA 90A.
a. Location: Smoke detectors listed for use in air distribution systems
shall be located:
1.) Downstream of the air filters and ahead of any branch
connections in air supply systems of greater than 2,000 cfin
capacity.
2.) At each story prior to the connection to a common return
and prior to any recirculation or fresh air inlet connection in
air return systems over 15,000 cfin capacity and serving
more than one story.
Exception #1: Return systems smoke detectors are not
required when the entire space served by the air distribution
system is protected by a system of area smoke detectors.
Exception #2: Fan units whose sole function is to remove
air from inside the building to outside the building.
b. Function. Required smoke detectors shall automatically stop their
respective fan(s) upon detecting the presence of smoke.
Exception: Where the return air fan is functioning as part of an
engineered smoke control system and a different mode is required.
C. Installation. Listed duct type smoke detectors shall be installed in
accordance with NFPA 72, National Fire Alarm Code.
1.) When an approved protective signaling system (fire alarm)
is installed in the building the smoke detectors shall be
connected to the protective signaling system in accordance
with NFPA 72. Activation of any air distribution system
smoke detector will cause a supervisory signal to be
indicated at a constantly attended location or will cause an
alarm signal.
2.) All detection devices used for the operation of smoke
dampers, fire dampers, fan control, smoke doors, and fire
doors shall be monitored for integrity in accordance with
NFPA 72, 1-5.8 where connected to the fire alarm system
serving the protected premises.
3.) When smoke detectors are installed in a building not
equipped with an approved protective signaling system,
the system shall
a.) cause a visual and audible signal in a normally
occupied area, and
b.) smoke detector trouble conditions shall be indicated
visually or audibly in a normally occupied area and
shall be identified as air detector trouble.
c.) The above signal requirements can be annunciated
with a simple remote test station with a sounder.
8. Smoke detectors having power supplied separately from the signaling
system (fire alarm) for the sole function of stopping fans do not require
standby power.
STANDARD MECHANICAL CODE
Automatic Fan Shutdown Requirements:
a. Systems serving buildings or spaces less than 25,000 cubic
feet in volume shall comply with the requirements of the
Standard Mechanical Code, Chapter 4, Section 406, 1997
Edition.
b. Capacity greater than 2,000 cfm.
Recirculating air systems with a fan capacity greater than 2,000
cfin shall automatically shut down by means of an approved smoke
detector placed in the return air stream prior to any exhausting
from the building or mixing with fresh air makeup.
C. Capacity 2,000 cfm or less.
Reciculating air systems with a fan capacity of 2,000 cfm or less,
but serving an area used for egress, shall have automatic fan
shutdown. This would be foyers, lobbies, stairways, corridors, and
passageways.
Code Conflicts.
a. There is some confusion as to the installation of duct type
detectors in the supply air or return air systems. The important
advantages of detectors being installed in the supply air is the
supply air is filtered and will be free of dust that can collect on the
detector(s). Some manufacturers specify the installation in supply
air only.
b. When duct type detectors are connected to a protective
signaling system (fire alarm), detectors shall be installed in the
sun UI air in accordance with NFPA 90A. Fire alarm systems are
Uniform Fire Safety Standards and the requirements shall be in
accordance with NFPA 101 Life Safety Code and not the Standard
Mechanical Code.
4W. o134
4 .46z Z 3
REQUEST FOR 30 DAY TEMPORARY POWER RELEASE
DATE:
q "76 /00
PERMIT NUMBER:
z60 40 Z21
St. Lucie County Comm. Devel. Dept.
Code Compliance Division
2300 Virginia Avenue
PROPERTY ADDRESS: A I X
7305 lowua2.Fua� 61,rc.l�
p
lerce, FL 34982-5652
Ph. (561) 462- 2165
56v/1� 462
D
SEP 2 12900
St. Lucie blic Works
THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO
THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOTTO EXCEED THIRTY (30)
DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARA-
TION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF, THIS
REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS:
1. This temporary power release is requested for the above stated purpose
only, and there will be no occupancy of any type, other than that permitted
by construction during this time period.
2. As witness by our signatures, we hereby agree to abide by all terms and
conditions of this agreement, including Building Division Policy, which is
incorporated herein by reference.
3. All conditions and requirements listed in the attached document entitled
"Requirements for 30 Day Power for Testing" have been fulfilled and the
premises is ready for compliance inspection.
We hereby release and agree to hold harmless, St. Lucie County, and their employees
from all liabilities and claims of any type or nature which may arise now or in the future
out of this transaction, Including any damages which may be incurred due to the
disconnection of electrical power in the event of violation of this agreement.
P£:TT 00, TE d3S Tod L0£ Sinucl Wd S99L59bT95
1 PAIII4 VM14CH INC.
Meohenieel • EloOrfeel • Civil • Engineering
1884 S.W. SL
' Pon 6L Lucie.
ro FL 8g984a4
Phone (581)185-9889 [ /�
FAX (561) 786-9833
May 10, 2000
St. Lucie County 9uilding Department ill
2300 Virginia Ave.
Ft. Pierce, FL 34982
Attn: Charles A. Cangianelli
Re: ATX
Permit No. 2oo407-91
To Whom It Way Concern:
Please be advised that the central corridor for the above
referenced project will be 1 hour fire rated with 20
minute, Class C fire doors.
, Revised plans will be provided.
Thank you for your attention to this matter.
Submitted by:
INC.
a
"4G7-mf3+
D1111 In Dip W
Radio Dispatched
" 24-Hour Service"
Corporate Center
1959 W. 9th Street Riviera Beach, FL 33404
1-800-285-PEST (7378)
CERTIFICATION OF PREVENTIVE SUBTERRANEAN
TERMITE SOIL TREATMENT (SLAB -PRETREATMENT
Owner ATX '
Lot Block
Sub -Division
StreetAddress 7305 COMMERCIAL CIR
City FORT PIERCE, FL
General Contractor RK DAVIS CONSTRUCTION
Sub Contractor
Main ILin Footage
Garage XX
Porches XX
Pool Patio N/A
Material Used N/A DURS13AN TC
ACCOUNT#. 3596160
Comments
Bldg.#
SQ Footage
14,776
Date
06/07/00
ld`lzt i -� <4
During the term of your unlimited warranty, any further treatment found necessary due to evidence of subterranean termites
(including Formosan Termites) will be done free of charge to the covered stmcture(s), and any structural damage necessitating
repairs (up to $1;000,000) caused by the subterranean termites (including Formosan Termites) will be paid by Hulett
Environmental Services. Hulett Environmental Services will annually reinspect the property only at your request. The
unlimited warranty term shall be one (1) year from date of treatment. The homeowner shall have the option of extending
the unlimited warranty annually (after the first year) for no less than four (4) additional years with payment gf annual
renewal ee. Please contact our office for further details.
Your contract covers all materials, labor, and service needed to control any active
-
infestation of subterranean termites, including Formosan Termites. An unlimited
warranty holder can, at anytime during the warranty period, request consultation
and advice concerning termites or other pests, at no charge to the owner. This
E
unlimited warranty is transferable should the property be sold or otherwise
' '-Zzr
v -
transferred. Hulett Environmental Services shall be notified in writing of new
- — =
ownership of the property. Your unlimited warranty has a $0 deductible.
d c ' : , t
Please contact our office for further details.
✓ :- v
".: ` _� ;
DEPARTMENT OF AGRICULTURE -BUREAU OF ENTOMOLOGY -RULE 5E 14.105 (3) F.A.0
irk
CERTIFICATIONSIGNED
A copy of this form must be obtained by the builder at the completion and files with the Building
Department before a certificate can be issued.
JUN 2 8 2000
5614657665 R.K. DAVIS
Mechanfcel • f9ectdcW • CIVII • Enginsedng
1984 S.W. BgtnW a St.'fIM
Pod SL Lucie, FL 34994
Phone (561) 7es-96M
FAX (561) 765-9933
November 03,, 2000
Re: ATX
Permit No. 20040291
TO Whom It May Concern:
996 P02 DEC 04 100 13:17
ZSAe&,O fotyf(0
Please be advised that our office has inspected the fire
wall for the above referenced project as indicated on sheet
A-2 of the plans and find that it meets with the plan and
our engineering requirements.
Thank you for your attention to this matter.