HomeMy WebLinkAboutSOIL REPORTm
.13LEngnuinengers
orrerwa Intl Estamisnetr l 7
Y.., irgj"t Is owc..mhment
MOISTURE - DENSITY
RELATIONSHIP REPORT
PROJECTNO. PSL-1297
TO CLIENT Polo Construction, Inc.
Polo Construction, Inc. C.C.
5500 Military Tr./ Ste 22-321
Jupiter, FL 'Aunoo aton-I'IS
33458 6t;ANNED 01a1ulw8ae.
)i Luce Countv 910Z h 1130
ATTN: John Kay
PROJECT Proposed Residence
CONTRACTOR
8060 Plantation Lakes Drive
Port St. Lucie, FL
PROCTOR NO. 1 DATETESTEDMar 15,2016 DATERECEIVEDMar 14,2016 DATESAMPLEDMar 14,2016
INSITU MOISTURE
N/A %
SAMPLED BY
J.Molina
TESTED BY
C.Costantino
SUPPLIER
On -site Material
SOURCE
Building Pad
MATERIAL IDENTIFICATION
MAJOR COMPONENT Brown Sand
MINOR COMPONENT
ROCK TYPE
iFEx1111
112.5
M
110.0
107.5
Z
W
0 105.0
0 102.5
100.0
COMMENTS
Page 1 of 1
COMPACTION STANDARD Modified Proctor,
ASTM D1557
COMPACTION PROCEDURE C: 6" Mold,
Passing 3/4"
RAMMER TYPE Automatic
TOTAL NUMBER OF TRIALS 4
3
4
1
6 7 8 9 10 11 12
MOISTURE CONTENT I%)
Mar 18,2016
of
TRIAL
NUMBER
WET
DENSITY
(Iblft3)
DRY
DENSITY
(Iblft3)
MOISTURE
CONTENT
(%)
1
112.4
105.3
6.7
2
116.6
107.3
8.6
3
120.5
109.0
10.5
4
120.7
107.5
-12.3
MAXIMUM
OPTIMUM
DRY
MOISTURE
DENSITY
CONTENT
(Iblft3)
(%)
CALCULATED
109.0
11.0
PER. / .
Inc. Richard G. loss!, P.E. #42003
Reporting of these test results constitutes a testing service only. Engineering interpretation or evaluation of test results is provided only on written request
IE �iV /col - oo7gro�
nuu'ng FIELD DENSITY
Engineers REPORT
Your Project is Our commitment
To
Polo Construction, Inc.
1533458
500 Military Tr./ Ste 22-321
upiter, FL
ATTN: John Kay
PROJECT Proposed Residence
REPORT NO. 1 NO.OF DENSITIES 12
PROJECTNO. PSL-1297
CLIENT Polo Construction, Inc.
C.C.
LOCATION 8060 Plantation Lakes Drive
Port St. Lucie, FL
TESTED BY J. Molina
DATE TESTED Mar 14 , 2016
CONTRACTOR
See Supporting Lab Testing
AREA Building Pad
Reports for Detailed Material
CONSTRUCTION TYPE (0-12")
Descriptions
MOISTURE
DRY DENSITY
DENSITY
LOCATION
Laboratory
COMPACTION
NUMBER
Soil Identifier
FIELD
LAB
FIELD
LAB
1
Proof -roll @ NE corner
Brown Sand
9.5
11.0
107.2
109.0
98
2
Proof -roll @ NW corner
Brown Sand
9.2
11.0
108.5
109.0
100
3
Proof -roll @ SE corner
Brown Sand
9.7
11.0
108.1
109.0
99
4
Proof -roll @ SW corner
Brown Sand
9.1
11.0
108.7
109.0
100
5
let lift @ NE corner
Brown Sand
9.3
11.0
108.3
109.0
99
6
let lift @ NW corner
Brown Sand
8.1
11.0
108.5
109.0
100
7
lot lift @ SE corner
Brown Sand
8.5
11.0
108.7
109.0
100
8
1st lift @ SW corner
Brown Sand
8.7
11.0
107.5
109.0
99
9
2nd lift @ NE corner
Brown Sand
8.1
11.0
107.2
109.0
98
10
2nd lift @ NW corner
Brown Sand
8.9
11.0
108.1
109.0
99
FIELD METHOD Nuclear ASTM D6938 SPECIFIED COMPACTION 98
LABORATORY METHOD Modified Proctor ASTM D1557
LOW DENSFTIES INDICATED
COMMENTS
(l
r�/ Ac
��
Page 1 of 2 Mar 18,2016 I J
Nutting Engineers of Florida, Inc. PER. I
y/
These test results only represent compaction measured at the location reported to a maximum depth of 12 inches below the surface tested. Richard G. loss!, P.E. #42603
This report does not reflect bearing capacity or deeper soil conditions.
This report shall not be reproduced, except in full or relied upon without prior written approval of Nutting Engineers of Florida, In"
Palm Beach (561) 736-4900 * Broward (954) 941-8700 * Miami Dade (305) 824.0060 * Port St. Lucie (772) 408.1050
nulting
Engineers
ffk�k� IEemMs1e1W
Your Project is Our Commitment
FIELD DENSITY
REPORT
TO
Polo Construction, Inc.
5500 Military Tr./ Ste 22-321
Jupiter, FL
33458
ATTN: John Kay
PROJECT Proposed Residence
REPORT NO. I NO. OF DENSITIES 12
PROJECTNO. PSL-1297
CLIENT POlo Construction, Inc.
C.C.
LOCATION 8060 Plantation Lakes Drive
Port St. Lucie, FL
TESTED BY J.Molina
DATETESTED Mar 14, 2016
CONTRACTOR
See Supporting Lab Testing
AREA Building Pad
Reports for Detailed Material
CONSTRUCTION TYPE (0-12")
Descriptions
DRY DENSITY
DENSITY
LOCATION
LaboratoryMOISTURE
COMPACTION
NUMBER
Soil Identifier
FIELD
LAB
FIELD
LAB
%
11
2nd lift @ SE corner
Brown Sand
7.3
11.0
108.5
109.0
100
12
2nd lift @ SW corner
Brown Sand
7.5
11.0
108.0
109.0
99
FIELD METHOD Nuclear ASTM D6938 SPECIFIED COMPACTION 98
LABORATORY METHOD Modified Proctor ASTM D1557
LOW DENSITIES INDICATED
COMMENTS
Page 2 of 2 Mar 18, 2016
Nutting Engineers of Florida, Inc. PER.(
These test results only represent compaction measured at the location reported to a maximum depth or 12 Inches below the surface tested. Richard G. �0551 P.E. #42603
This report does not reflect bearing capacity or deeper soil conditions. r
This report shall not be reproduced, except In full or relied upon without prior written approval of Nutting Engineers of Florida, Inc..
Palm Beach (561) 736-4900 * Broward (954) 941-8700 * Miami Dade (305) 824-0060 * Port St. Lucie (772) 408-1050
u "maa uK.r esu+pmnca reor
rumRv(csnh oeoCommhmenr
RELATIONSHIP REPORT
PROJECTNO. PSL-1297
To CLIENT Polo Construction, Inc.
Polo Construction, Inc. C.C.
5500 Military Tr./ Ste 22-3 SCANNED
Jupiter, EL hECEIVED BY
33458 St. Lucie County
MAR 2 1 2016
ATTN: John Kay
PROJECT Proposed Residence
CONTRACTOR
8060 Plantation Lakes Drive
Port St. Lucie, FL
PROCTOR NO. 1 DATETESTEDMar 15,2016 DATERECEIVEDMar 14,2016 DATESAMPLEDMar 14,2016
INSITU MOISTURE
N/A rya
SAMPLED BY
J.Molina
TESTED BY
C.Costantino
SUPPLIER
On -site Material
SOURCE
Building Pad
MATERIAL IDENTIFICATION
MAJORCOMPONENT Brown Sand
MINOR COMPONENT
ROCK TYPE
115.0
112.5
M
110.0
a
107.5
z
LU
G 105.0
100.0
COMMENTS
COMPACTION STANDARD Modified Proctor,
ASTM D1557
COMPACTION PROCEDURE C: 6" Mold,
Passing 3/4"
RAMMER TYPE Automatic
TOTAL NUMBER OF TRIALS 4
6 7 8 9 10 11 12
MOISTURE CONTENT (%}
TRIAL
NUMBER
WET
DENSITY
(lbw)
DRY
DENSITY
ohm)
MOISTURE
CONTENT
(%)
1
112.4
105.3
6.7
2
116.6
107.3
8.6
3
120.5
109.0
10.5
4
120.7
107.5
12.3
MAXIMUM
OPTIMUM
DRY
MOISTURE
DENSITY
CONTENT
(IbNt3)
(%)
CALCULATED
�\J'QBU D)*
11.0
`
Page 1 of 1 Mar 18, 2016 Nutting Engineers of Florida, Inc.
Reporting of these test results constitutes a testing service only. Engineering interpretation or evaluation of test a
provided only bij i
't pROFZ�y
FIELD DENSITY
C>a Engen�� REPORT
Your project IS our commuted
PROJECTNO. PSL-1297
TO CLIENT P010 Construction, Inc.
Polo Construction, Inc. C.C.
5500 Military Tr./ Ste 22-321
Jupiter, FL
33458
ATTN: John Kay
PROJECT Proposed Residence
REPORT NO. 1 NO. OF DENSITIES 12
LOCATION 8060 Plantation Lakes Drive
Port St. Lucie, FL
TESTED BY J.Molina
DATETESTED Mar 14, 2016
CONTRACTOR
See Supporting Lab Testing
AREA Building Pad
Reports for Detailed Material
CONSTRUCTION TYPE (0-1211)
Descriptions
MOISTURE
DRY DENSITY
DENSITY
LOCATION
COMPACTION
NUMBER
Soillderltifer
FIELD
LAB
FIELD
LAB
%
1
Proof -roll 0 HE corner
drawn Sand
9.5
11.0
107.2
109.0
98
2
Proof -roll 0 NH corner
Brawn Sand
9.2
11.0
108.5
209.0
100
3
Proof -roll a se mraer
Brows sand
9.7
11.0
108.1
109.0
99
4
Picof-roll 0 SW wrnar
Brown Sand
9.1
11.0
108.7
109.0
100
5
let lift 0 NE tamer
Brown sand
9.3
11.0
108.3
109.0
99
6
lat lift a NW mrner
Brown Sand
8.1
11.0
108.5
109.0
100
7
ist lift 0 SE corner
Brown sand
8.5
11.0
100.7
109.0
100
8
lat lift @ SW comer
Brown sand
8.7
11.0
107.5
109.0
99
9
2nd lift 0 NE corner
arowa sand
8.1
11.0
107.2
109.0
98
10
2nd lift 0 NW corner
Brows. sand
8.9
11.0
106.1
109.0
99
FIELD METHOD Nuclear ASTM D6938 SPECIFIED C ffl TON 98
`1"ND�
LABORATORYMEfHOD Modified Proctor ASTM D1557 LO fS
COMMENTS
v
0
Page 1 of 2 Mar 18, 2016 Nutting Engineers of Flodda, Inc, PER. C 1
ThCaa leatraaWte m1yr6preeent C0M2Cion measured at the location reported to madmum oyt2 lachae balwib, a� %m tuatad `
d`A"'
ltdareportawstat ntlectbemtng capacity ardeeperson condhlora
Tw teporteha0nutberepmducad. oi- lnmwrWNdupmethoutpdwwrsum pmvalotNumnBEngine crfRodda,lam j V:
Palm Beach (661) 736-4900 * Broward (964) 941-8700 * Miami Dade (305) 824-0060 * Port
E�gin�s--vs, FIELD DENSITY
"j REPORT
Yois Pro$cris ourcmnmemem _ ' '
PROJECTNO. PSL-1297
To CLIENT Polo Construction, Inc.
[33458
olo Construction, Inc. C.C.
500 Military Tr./ Ste 22-321
upiter, FL
ATTN: John Kay
PROJECT Proposed Residence
REPORT NO. 1 NO. OF DENSITIES 12
LOCATION 8060 Plantation Lakes Drive
Port St. Lucie, FL
TESTED BY J. Molina
DATE TESTED Mar 14 , 2 016
CONTRACTOR
See Supporting Lab Testing
AREA Building Pad
Reports for Detailed Material
CONSTRUCTION TYPE (0-12 rt)
Descriptions
DENSITY
LOCATION
boratory
3oail
MOISTURE
DRY DENSITY
COMPACTION
FIELD
LAB
FIELD
LAB
NUMBER
deer
11
2nd 11ft 0 BE corner
Brown Sand
7.3
11.0
108.5
109.0
100
12
2nd lift @ Se corner
Brown Bend
7.5
11.0
10B.0
109.0
99
FIELD METHOD Nuclear ASTM D6938 �Ht�1�'I N 98
"
LA80RATORYMETHOD Modified Proctor ASTM D1557 LPECIA
COMMENTS \\ /
i/ Page 2 of 2 Mar 16, 2016
�o
Nutting Engineers of Florida, Inc. PER K
Them t ntromdteomytepreaea Kittle,
location rewtoemaddepther4YindmbeawemeembsLdThasredo0w"a:tb6ueapdtyiwd id,"Card
sKBwu, &I d551� rt'grrrti(�
ro
TbiainmberePanN.dWonwNmutPdwwanoPPOvaiornoUj;fim ofRmki%bw
Palm Beach (561) 736-4900 * *
Broward (954) 941-8700 A iiami Dade (305) 824-0060 * Part
ri 1111111"'