Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEt COL)NTY v F L 0 R i D A a; alop oyoLl Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46 Certification for Design Load Compliance Project Name: Queen Island Preserve Lot 6 Residence Project Address: 4440 Al (North Hutchinson Island); Fort Pierce, Florida 34949 SEP 21 2015 Permit #: Occupancy Type: R-3 Construction Type: Type Vb INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. LUCI@ COUI1tV o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: X 1 _II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 76o Vult mph X ASD _LRFD End Zone Width: 5.1 ft S. Mean Roof Height 30' ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:42.0 Zane 2: 73.0 Zone 3: 108.0 Zone 4:49•7 Zone 5:61.4 Garage: N/A , 7. Design Loads: Floor: 55 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 100 PSF Dock:`WA PSF Deck: 100 PSF Stairs: 60 PSF Fence: N/A PSF Railings: 200 PSF 8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF. Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the'best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced. by St. Lucie County. I alsd''certify that structural elements depicted on these plans provide adequate resistance to the design r. forces specifie&" .. David S. Knight, P.E. Print Name Knight McGuire & Associates, Inc. 41060 Cert # & Co. Cert Auth. 80 Royal Palm Pointe Suite 401; Vero Beach, F666L���32960 Company Name & Address COPY