Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEt :.ning & Development Services Departme, , Building & Code Regulations Division • 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15 3 Certification for Design Load Compliance S$ LuC11?COunN Project Name: PSL Reserve at Port St. Lucie Signage Project Address: 1500 Tiffany Club Place Port St. Lucie, FL 34952 1-0143, Permit #: 151Occupancy Type: Construction Type, } INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. t•'i ' • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving thqfollowin�g:' o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. , Structure Designed as (check one): _Enclosed _Partially Enclosed _Open 3. Risk Category: X_I _II _III _ IV Exposure Category: X B _C _D 4. Design Wind Veloci* 150 mph _ASD X LRFD End Zone Width: 5. Mean Roof Height -- Roof Pitch: -- :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -- Zone 2: -- Zone 3: Zone 4:. Zone 5: Garage: 7. Design Loads: Floor: -- PSF Roof/Dead: -- PSF Roof/Live: -- Balcony: PSF Dock: -- PSF Deck:---:- PSF Stairs: -- PSF Fence: -- PSF Railings:. -- PSF 8. Were Shear Walls Considered For Structure 7 _ Yes X Not Applicable Explain Why Not: Proposed Work is not a Structure (Building) 9. Is A Continuous Load Path Provided? x Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on.these plans provide adequate resistance to the design forces specified: 2' t? Signature, Date, and Seal C. Calvert Montgomery 00160 Print Name Cert # & Co. Cert Auth. C. Calvert Montgomery & Associates, Inc. P.O. Box 92 - Stuart, FL 34995 Company Name & Address a Revised 07/25/2014 ,.