Loading...
HomeMy WebLinkAboutGENERATOR PAPPERSGENERAC® I INDUSTRIAL POWER SG035 Standby Power Rating 35 kW 44 WA 60 Hz Prime Power Rating* 32 kW 39 kVA 60 Hz Industrial Spark -ignited Generator Set SCANNED EPA Certified Stationary Emergency BY St. Lucie County 'EPA Certified Prime ratings are not available in the U.S. or its Territories Codes and Standards Generac products are designed to the following standards: c®us UL2200, UL508, UL142, UL498 tH NFPA70, 99,110, 37 racwar nec NEC700, 701, 702, 708 IS09001, 8528, 3046, 7637, Pluses #2b, 4 jl l NEMA ICs10, MG1, 250, ICS6, AB1 ANSI C62.41 Amortean World sfandad, hutlfaro } , IBC 2009, CBC 2010. IBC 2012, ASCE 7-05, w osl /pd ASCE 7-10, IMES AC-156 (2012) Image used for iflwtrabon puryases arty Powering Ahead For over.50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. of options, ing us to cally every. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. Generac is committed to ensuring our customers' service support continues after their generator purchase. GENERAC' I INDUSTRIAL --��- POWER SGO35 60 and FeOke"s: ENGINE SYSTEM General • Oil Drain Extension • Air Cleaner • Fan Guard • Stainless Steel flexible exhaust connection • Critical Exhaust Silencer (enclosed only) • Factory Filled oil • Radiator duct adapter (open set only) Fuel System • Primary and Secondary Fuel Shutoff • Flexible Fuel Line - NPT Connection Cooling System • Closed Coolant Recovery System • UV/Ozone resistant hoses • Factory -installed Radiator • Radiator drain extension • 50/50 Ethylene glycol antifreeze Engine Electrical System • Battery charging alternator • Battery Cables • Battery Tray • Solenoid activated starter motor • Rubber -boated engine electrical connections CONTROL SYSTEM ALTERNATOR SYSTEM • UL2200 GENprotect'" • Class H insulation material • 2/3 Pitch • Skewed Stator • Brushless Excitation • Sealed Bearings • Amortisseur winding • Full load capacity alternator GENERATOR SET • Internal Genset.Vibration Isolation • Separation of circuits - high/lowvoltage • Separation of circuits - multiple breakers • Wrapped Exhaust Piping • Standard Factory Testing • 2 Year Limited Warranty (Standby rated Units) • 1 Year Warranty (Prime rated units) • Silencer mounted in the discharge hood (enclosed only) ENCLOSURE (if selected) • Rust -proof fasteners with nylon washers to protect finish • High performance sound -absorbing material • Gasketed doors • Stamped air-intake louvers • Air discharge hoods for radiator -upward pointing • Stainless steel lift off door hinges • Stainless steel lockable handles • Rhino Coat'" -Textured polyester powder coat • Real/Reactive/Apparent Power • Single point ground • All Phase AC Voltage • 15 channel data logging • All Phase Currents • 0.2 msec high speed data logging _ • oil Pressure • Alarm information automatically comes up • Coolant Temperature on the display • Coolant Level Alarms • Engine Speed • Oil Pressure (Pre -programmable Low • BatleryVoltage _ Pressure Shutdown) Control Panel • Frequency • Coolant Temperature (Pre-programmed High • Digital H Control Panel - Dual 420 Display • Date/rime Fault History (Event Log) Temp Shutdown) • Programmable Crank Limiter • Isochronous Governor Control • Coolant Level (Pre-programmed Low Level • 7-Day Programmable Exerciser • Waterproof/sealed Connectors Shutdown) • Special Applications Programmable PLC • Audible Alarms and Shutdowns • Low Fuel Pressure Alarm • RS-232/485 • Not in Auto (Flashing Light) • Engine Speed (Pre-programmed Over speed • All -Phase Sensing DVR • Auto/Off/Manual Switch Shutdown) • E-Stop (Red Mushroom -Type) • Battery Voltage Warning • Full System Status • NFPA110 Level I and II (Programmable) • Alarms & warnings time and date stamped • Utility Monitoring • Customizable Alarms, Warnings, and Events • Alarms & warnings for transient and steady • Low Fuel Pressure Indication • Modbus protocol stale conditions • 2-Wire Start Compatible • Predictive Maintenance algorithm • Snap shots of key operation parameters • Power Output (kW) • Sealed Boards during alarms & warnings • Power Factor • Password parameter adjustment protection • Alarms and warnings spelled out (no alarm • kW Hours, Total & Last Run codes) GENERAC' I INDUSTRIAL o -�..m� POWER SG035 �C?i9g le Qpt = ENGINE SYSTEM General O Engine Block Heater O Oil Heater O Air Filter Restriction Indicator O Stone Guard (Open Set Only) O Critical Exhaust Silencer (Open Set Only / Standard on Ultra Low Emissions Option) Engine Electrical System O 10A UL battery charger O 2.5A UL battery charger O Battery Warmer ALTERNATOR SYSTEM O Alternator Upsizing O Anti -Condensation Heater O Tropical coating O Permanent Magnet Excitation CONTROL SYSTEM GENERATOR SET O Gen -Link Communications Software (English Only) O Extended Factory Testing (3 Phase Only) O IBC Seismic Certification O 8 Position Load Center O 2 Year Extended Warranty O 5 Year Warranty O 5 Year Extended Warranty CIRCUIT BREAKER OPTIONS O Main Line Circuit Breaker O 2nd Main Line Circuit Breaker O Shunt Trip and Auxiliary Contact O Electronic Trip Breakers ENCLOSURE O Standard Enclosure O Level Sound Attenuation O Level 2 Sound Attenuation O Steel Enclosure O Aluminum Enclosure O 150 MPH Wind Kit O 12 VDC Enclosure Lighting Kit O 120 VAC Enclosure Lighting Kit O AC/DC Enclosure Lighting Kit O Door Alarm Switch O 21-Light Remote Annunciator O Remote E-Slop (Break Glass -Type, Surface O Remote Communication - Modem O Remote Relay Panel (8 or 16) Mount) O Remote Communication - Ethernet O Oil Temperature Sender with Indication O Remote E-Stop (Red Mushroom Type, O 1 OA Run Relay Alarm Surface Mount) O Ground fault indication and protection O Remote E-Stop (Red Mushroom Type, functions Flush Mount) ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM O Coolant heater ball valves O Fluid containment pans O Special Testing O Battery Box ALTERNATOR SYSTEM ENCLOSURE O 3rd Breaker Systems O Motorized Dampers O Enclosure Ambient Heaters O Spare inputs (x4) / outputs (x4) - H Panel Only O Battery Disconnect Switch Rating Definitions .-� Standby —Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. Prime —Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10%overload capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications. Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP). GENERAC' I INDUSTRIAL POWER SG035 application and engineering data ENGINE SPECIFICATIONS General Make Gylinder� '- Type Displacehent -1 Cu n) Bore - mm (in) ( Stroke -ruin (In)' Compression Ratio Intake Air Methodm_ Number of Main Bearings Connecting Ro_d_s_ Cylinder Head Cylinder Liners Ignition Rstoms, Crankshaft LiflerType Intake Valve Material Exhaust Valve Material Hardened Valve Seats Generac 8i V 5.4 (32953) 90.17 (3.55) 105.92. (4.17) 9:1 Naturally Aspirated ; 4 Forged Aluminum No Single Fire Aluminum Alloy Nodular Iron Hydraulic Steel Alloy - HardenedSteel Yes Engine Governing Governor Electronic Fnquency)ieguladon(SteadyState) +1-0.25% ALTERNATOR SPECIFICATIONS Standard Model UPoles Field Type Insulafion:Class Rotor Insulation Class - Stator Total Harmonic Distortion ., Telephone Interference Factor (TIF) Standard! Excitation Bearings Coupling;:.. Prototype Short Circuit Test 390 4', Revolving H, H <5% <50 Bfushless Sealed Ball Flexibile Disc Yes Lubrication System Oil Pump Type Gear Oil Filter Type Fult-(lowspin-oncarrwge Crankcase Capacity- L (qts) 5.7 (6) Cooling System Cooling System Type Pressurized Closed Recovery Water PumpFloyi-gpm(I'prn) '` 38044) Fan Type Pusher fanSpewrpm) ;2143,4 Fan Diameter mm (in) 508 (20) ,Coolant Heater Wattage Coolant Heater Standard Voltage 120V Fuel System Fuel Type Carburetor Secondary Fuel Regulator Fuel Shut Off Solenoid Operating Fuel Pressure Enaine Electrical System Battery Size Ground Polarity Natural Gas, Propane Vapor Dovm Draft Standard Shandard� _ .:..7° - It" H20 12 VDC Negative Voltage Regulator Type Full Digital Number of Sensed Phases All, Regulation Accuracy (Steady State) +/-0.25% GENERAC I INDUSTRIAL memlIiiiiiiiiiiiii POWER SG035 operating data POWER RATINGS Single -Phase 120/240 VAC @1.Opl M(ee-Phase120/208VAC'@0:8pt - Three -Phase 120/240 VAC @O.8pf ¢¢ hree PPhase 2771480 VAC @a Bpi: Three -Phase 346/600 VAC @0.8pt STARTING CAPABILNTES (sKVA) Natural Gas Propane Vapor 35 kW Amps: 146 35 kW Amps: 146 35:MW Amps: `1Z1 _ 35 kW Amps: '12t 35 kW Amps: 1" 35 kW Amps: 105 35 "kW _,_ Amps.. 53.. ._ 35kW "; Amps: 53 35 kW Amps: 42 35 kW Amps: 42 sl vs. Voltage Dip 480 VAC 208/240 VAC Alternator kW ' 10% 15,% 20% 25% `': 30% - 35%1 10% 15% ' 20% ,r25%' 30% 35% Standard 35 24 : 35 48 60 :. 72 84 18 27 36 45 54 63 '1 Upsiie1 40 27 41. 54 68 :L. 81 95„ 20 3t 41 :; 51 ` 61 ,, 71 Upsize2 50 34 .- 52 -: 69 `86 103 120 26 39 52 ;. 65 6 77 90 ; UPsize3 60 42 63: 83 704 `:.. 125 146' 32 47 62 t10 FUEL CONSUMPTION RATES' Natural Gas -ION (m3/hr) Percent Load Standby 25% 239 (6.8) 50% 409(11%) -' 75% 553 (15.7) UK - 68.2(t93) :. `Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Propane Vapor -X3/hr (m3/hr) Percent Load Standby 25% 69.8(2.0) "50% 1191(3.d) 75% 161.E 1100% 219.8 Standby Air Flow (inlet air combustion and radiator) fP/min (m3/min) 2460 (69.7) Coolant Flow per Minute. gpm Rpm) 38(144) Coolant System Capacity gal (L) 3(11.36) Heaf Rejection to Gdoladt ' ` BTU/hr 444,000 ' Max Operating Air Temp on Radiator OF (OC) 122 (50) Max Operating Ambient Temperature(betmederate) OF(OC) 110(6.3) Maximum Radiator Backpressure in H 0 0.5 COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power char (m3/min).r 87(2.5) ENGINE EXHAUST Standby Rated Engine Speed rpm 1800 HorsepoweratRatedkW" hp .. 54 Piston Speed f /mm (in/min) 1251 (381) BMEP _ Psi: 72 - Niel to'EMMCns Data Sheet' for mt taw bHP for EPA and SCAdMO permitanp purposes Standby Exhaust Flow (Rated Output) rim (m3/min) 260 (7.4) Maximum Recommended Back Pressure InHg - _ 1.5 Exhaust Temp (Rated Output) T (OC) 900 (482) Fxhausi Outfbt Sim (Open Set) in 25^'1,D, Flex (NO muffler):: Deacon - Operational characters ics consider maxnnum ambient candi8ans. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with IS03046, BS5514, IS08528 and DIN5271 standards. GENERAC' I INDUSTRIAL _�r•�I! POWER SG035 dimensions and weights 1—L-I OPEN SET (Includes Exhaust Flex) L x W x H in (mm) 76 (1930) x 37.4 (949.9) x 47 (1193.8) Weight Ibs (kg) 1575 (714) STANDARD ENCLOSURE L x W x H in (mm) 94.8 (2408.9) x 38 (965.1) x 49.5 (1258.1) Weight Ibs (kg) Steel: 2100 (952) Aluminum: 1754 (795) LEVEL 1 ACOUSTIC ENCLOSURE Lx W x H in (mm) 112.5(2857.1) x 38(965.1) x 49.5(1258.1) Weight Ibs (kg) Steel: 2140 (970) Aluminum: 1767 (8011 LEVEL 2 ACOUSTIC ENCLOSURE L x W x H in (mm) 94.8 (2407) x 38 (965.1) x 62 (1573.9) Weight Ibs (kg) Steel: 2328 (1056) Aluminum: 1831 (830) YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER I Snecileatten ChaaNedstics may change wimoN notice. Neaseconsuft a Generate Nwzr Systems Intlustrul Dealer for detailed installation t awings. Generac Power Systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac.com @2013 senate Power Systems, Ine. All rights reserved. AD snecifsa5ons are subject to charge wNwN matloe. Part No. OK4265-0( Primed in U.SA 12/10/13