Loading...
HomeMy WebLinkAboutSIGN DESIGN CALCULATIONSn EnCon Services, Inc. Sign Design Calculations 6GANNED BY St. Lucie Countv Job Description PREPARED BY: SP #205 EnCon Services, Inc., FLEB #9394 2475 Midway Rd. 2272 Jaudon Road, Dover, FL 33527 Fort Pierce, Florida 813-655-3373 1 OFT Monument Sign Design per Florida Building Code, 5th Edition (2014), Section 16 Wind Load, DATE SIGNED: 11130/2015 ASCE 7-10, Load Case: D + 0.6W ,``,11p1tt11111!!lp7�7j'' Risk Category II 1 `��,<.�.•C E !yKzt Exposure C No 77G Kd 0.85 Kz 0.85 V 170 mph A =• STATE OF : I Cf G 1.44 0.85 ��'•• �iilOR%OP' N �'ossZO/NIAL4-- Number of Poles 1 *o0v Wind Pressure (PSF) af, Sign Area Distance to Center P = Force Moment (s ft Ib ft-Ib Top 120.72 5.53 4755 26311 Middle 0 0 Bottom 0 0 Poles 0 0 Totals 4,755 26,311 Required Flexural Strength (kip-ft) 26.3 per pole Provided Flexural Strength (kip-ft) 44.1 HISS 8 x 8 x 1/4 A500 B Steel Base Plate Design Distance Between Bolts 11 14351 Tension on Bolts (LB) Number of Bolts per Base Plate 4 Use 01" x 36" Long Anchor Bolts, F1664 Gr55 with Double Nuts Embedded Plate Width B (IN) 14 0.83 Plate thickness (IN) Bolt Spacing d (IN) 11 Use 1-1/4" A36 Plate Diameter of Pole (IN) 8 Base Design Number of Bases 1 Diagonal B (FT) 10.20 Base Size Required Lateral soil pressure (LB/SF/FT) 150 5.0 FT Deep Depth (Estimated) (FT) 5 10.0 FT Wide S1 500 2.0 FT Long Design Depth (FT) 4.88 Ft 11/30/2015 BP 205 Fort Pierce LOFT man creative signs