1. Design is in accordance with the Florida Building Code 5th Edition (2014) for
use within and outside the High Velocity Hurricane Zone (HVHZ).
2. Wind loads have been calculated per the requirements of ASCE 7-10 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly specified
herein and/or in accompanying engineering drawings. The existing host
`'structure (if any) must be capable of supporting the loaded system as
verified by building department or architect / engineer of record. No
warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
S. Where site conditions deviate from those noted herein, revisions may be
required or a separate site -specific engineering evaluation performed.
6. Aluminum components in contact with steel or embedded in concrete shall
be protected as prescribed in the 2019 Aluminum Design Manual, Part 1.
Steel components in contact with, but not encased in, concrete shall be
coated, painted, or otherwise protected against corrosion.
7. Engineer seal effixed'hereto validates structural design as shown only. Use
of this specjfi�atjon by contractor, et. AI, indemnifies and saves harmless
this engineer f1'r all costs & damages including legal fees & apellate fees
resulting frpm deviation from this design.
SCABNNED
St. Lucie County
THEM PLANS AND ALL SROPOS50 WOMK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTOIJS THAT
WAY BE NEC£SSAXY M OMM TO
CUMLY W M ALL APPMABLE CODES.
Index:
Pg 1
Cover
Pg 2
Wind Loads
Pg 3
Anchor Design
Engineer.'s signature and seal valid
focpages 1 through'_y3
ov 02W
Christian-;.anglePEW 67382
Easy Sea(S ce AuthIt31124
Federal 3432nzoo Easy Setals .com Page 1
B0000 Raton,
Baton, FL 33432
J-1
ASCE 7-10 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs
V= 170mph Basic wind speed
Exposure C
Calculations
a= 9.5 3-sec gust speed power law exponent
zg = 900, Nominal hL of atmos. boundary layer
Gcpi = 0 Internal pressure coed
ASD Load Combo CDeff. 0.6
Kd = 0.85 Directionalityfactor
KA = 1.0 Topogrophicfactor
A = 10sqft Tributary area
170 mph - Exp "C'
WALL -MOUNTED SIGNS
ASD WIND PRESSURES
SIGN CENTER CORNER
HEIGHT (Zone 4) t (Zone 5) qz
is It 35.2 psf 44.8 psf 53.4
0 ft 37.4 psf 47.6 psf 2 56.7
39.2 psf 49.9 psf 25ft 59.4
30ft 40.8 psf E 51.9 psf 61.8
35ft 42.1 psf 53.6 psf r. 63.8
40ft 43.3 psf 55.1 psf 65.6
45ft t4. 44A psf E 56.S psf 67.3
50ft 45A psf E S7.8 psf 68.8
it 55 ft 463 psf 58.9 psf J 70.2
60ft 47.2 psf 60.0 psf 71.5
70ft 39.9 psf 79.7 psf 73.8
80ft 41.0 psf E 82-0 psf 75.9
90ft 42.0 psf S&I psf 77.8
®p Y
10D It 43.0 psf 86.0 psf 79.6
E COP
1, 110 ft 43.8 psf 87.7 psf Z- 81.2
120 It 44.7 psf E 893 psf 82.7
130 ft 45.4 psf E 90.9 psf q 2 84.1 -z
140 ft 46.1 psf 923 psf 85.4
150 It 46.8 psf 93.6 psf 86.7
175 ft 48A psf 96.7 psf 89-S _r,
200 ft
49.7 psf 99.5 psf 92.1
250 ft j 52.1 psf 104.2 psf 96.5 THEOr..PLQIS AND ALL PROPdS5D WORK
ARE SUBJECT TO ANY COMECTIoNG
REQUIRED BY KLD INSPECTORS TEAT
MAY BE NECLOSSA%y IN OADR TO
CM-OU WI il-I ALL APPUCA&E CODES.
Page 2
WaN Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure:
Sign type:
Sign size:
Wall material:
Anchor type/size:
Anchor tensile capacity:
.Check Anchors for Paaiiout
P = 51.9 psf
Channel Letter
A = 4.0 sgft (per letter, critical)
Wood CDX or eguly, thickness to match Min Embed
1/4" Toggle Bolt (r)
Ref: Powers Toggle Bolt, catalog
Min Embedment: 0.5"
Min edge dirt: 2"
Tcap = 87.5 lb (per anchor)
Total Reaction: Rt = 208 lb ... = P*A (per letter)
No. of anchors req'd: n = 2.4 anchors per letter ... = Rt/rcap
Total anchors required: 3 anchors per letter
Min Spacing: 1.5"
OK, critical anchor option shown.