HomeMy WebLinkAboutDESIGN CALCULATIONSr" easyseals.com �ES!C^ C,�.l_CULl�T ONS FOR GENERAL NOTES: 1. Design is in accordance with the Florida Building Code Sth Edition (2014) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2_ Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host 1''structure (if any) must be capable of supporting the loaded system as verified by building department or architect / engineer of record. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. S. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2010 Aluminum Design Manual, Part L Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. SCHNNELr BY St. Lucie Counts Index: PR 1 Cover P92 Wind Loads Pg 3 Anchor Design Engineer's signature and seal valid IX ,.forpages 1 through' x Easy SealsP'' " CeXAuth ft 31124 Raton, &SY Federal Hwy, g200 Sealls .coal Page 1 Bocaaca Raton, FL 33432 7 CAALCULA II®Mir'®R@ ALL -MOUNTED SIGNS WaH Sign Anchov Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: Wall material: Anchor type/size: p = 51.9 psf Channel Letter A= 4.0 sgft (per letter, critical) Wood CDA or equiv, thickness to match Min Embed 1/4" Toggle Bolt (r) Ref: Powers Toggle Bolt, catalog Min Embedment: 0.5" Min edge dist: 2" Anchor tensile capacity: Tcap = 87.5 lb (per anchor) Check Anchors -folr Pu lout Total Reaction: Rt= 208 lb ... =PaA (per letter) No. of anchors req'd: n = 2.4 anchors per letter ... = RVFcap Total anchors required: 3 anchors per letter Min Spacing: 1.5" OK, critical anchor option shown. Page 3 !!lam '- - '• ASCE 7-10 Design Wand Loads WALL -MOUNTED SIGNS Building Specs V = 170 mph Basic wind speed Exposure C Calculations a = 9.5 3-sec gust speed power law exponent 2e = 900' Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff 170 mph - Exp "V WALL MOUNTED -SIGNS ASD WIND PRESSURES SIGN " CENTER CORNER HEIGHT (Zone 4) (Zone 5) 15 ft L' 352 Psf 44.8 psf 20 ft 37A psf 47.6 psf 25 ft 39.2 psf 49.9 psf .; 30 ft 40.8 psf SL9 psf 35 ft 42.1 psf 53.6 psf i 40 ft 433 psf 55.1 psf 45 ft t 44A psf 56.5 psf 50 ft 45A Psf 57-8 psf 55 ft 463 psf 58.9 psf� f 60 ft 47.2 psf 60.0 psf 70 ft 39.9 psf 79.7 psf 80 ft 41.0 psf SLO psf i' 90 ft .: 42.0 psf 84.1 psf '-; 100 ft f " 43.0 psf 96.0 psf !� 110 ft `.; 43.8 psf 87.7 psf j' 120 ft 44.7 psf 893 psf i, 130 ft 45A psf 90.8 psf ii 140 ft 46.1 psf 92.3 psf 150 ft 46.8 psf 93.6 psf 175 ft 48A psf 96.7 psf 200 ft Y -•- 49.7 psf 99.5 psf 250 ft 52.1 ad E 1042 psf sl ASD Load Combo Coeff: q: 53.4 56.7 59A 61.8 63.8 65.6 67.3 68.8 70.2 71.5 73.8 75.9 77-8 79.6 81.2 82.7 84.1 85.4 86.7 89.5 92.1 96.5 M Kd = 0.85 Directionality factor KA = 1.0 Topographic factor A = 10 sq ft Tributary area i�•��-�r- ki Page 2