Loading...
HomeMy WebLinkAboutSTRUCTURAL OPINION LETTER.i CROWN FILE COPOCCASTLE Date: December21, 2015 David Robertson Crown Castle Crown Castle SCANNED 2000 Corporate Drive 12725 Moms Road Extension, Suite 400 BY Canonsburg, PA 15317 Alpharetta, GA 30004 St. Lucie County (724) 416-2000 Subject: Structural Opinion Letter Carrier Designation: Metro PCS Co -Locate Carrier Site Number: A2P0322M Carrier Site Name: Hutchinson Island Club Crown Castle Designation: Crown Castle BU Number: 851971 Crown Castle Site Name: Hutchinson Metro PCS FTP247 Crown Castle JDE Job Number: 352961 Crown Castle WO Number: 1152921 Crown Castle APP Number: 312224 Rev. 2 Site Data: 10410 S Ocean Dr, Jensen Beach, St. Lucie County, FL Latitude 27°16'21.5", Longitude-80012'21.2" Existing Rooftop Penthouse Dear David Robertson, Crown Castle is pleased to submit this "Structural Opinion Letter" for the structural integrity of the aforementioned rooftop penthouse. This evaluation has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 1152921. The purpose of the opinion letter is to determine the suitability of the existing rooftop penthouse for the replacement of existing antennas as specified in Tables 1 & 2 on the next page. This opinion is consistent with the guidelines as stated in the 2014 Florida Building Code, 5a' edition, Section 1509 and Existing Building, Section 1103.3, Exception 2. Based on a comparison of the existing antenna configuration and the proposed loading, we have determined the existing rooftop penthouse /S sufficient for the proposed loading. Evaluation of the existing antenna mount and attachment fasteners is beyond the scope of this letter. We at the Crown Castle Engineering Department appreciate the opportunity of providing our continuing professional services to you. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted, y •y e.�A f Ste?' Bradley Earl Byrom, P.E. =m; No. 63698 u _ Protegg)gnal Engineer License: #63698 Bradley E. Bryom, P.E. Senior Project Engineer ^.0` ; CertlilceteofAuthurization:#28970 STATE OF s �,= r fi, —k �11Z1aO/ 6 ENG-FRM-10035, Rev — (10/09/106) ri Existing Rooftop Penthouse Structural Opinion Letter Project Number 1152921, Application 312224, Revision 2 Table 1 — Proposed Antenna and Cable Information December 21, 2015 CCI BUNo. 851971 Page 2 Center Number Line Number of Antenna Antenna Mount of Feed Elevation Antennas Manufacturer Model Information Feed Line (ft) Lines Size 3 ANDR_EW _ LNX-6514DS-Al M 120 3 CELLMAX CMA-B/6520/EO-8 TECHNOLOGIES 3*J COMMSCOPE* TMAT1921B78-21A* *Equipment to be installed inside penthouse. Equipment does not contribute to wind area. Table 2 — Existing Antenna and Cable Information Center Number Feed Line Number of Antenna Antenna of Elevation Antennas Manufacturer Model Feed Line (ft) Lines Size (in) 120 6* 1 Andrew* DB950F5E* 6 7/8 'Existing Equipment, to be removed ENG-FRM-10035, Rev — (10/09/06)