Loading...
HomeMy WebLinkAboutCERTIFICATE FOR DESIGN LOAD COMPLIANCEi Planning & Development Services Department jCHNNE® Building & Code Regulations Division BY 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 3p LuCie COUnfy Certification for Design Load Compliance Project Name: FPL Security Training Building Project Address: (os0/ 5'06171-1 ir£',-AI bP111 `' PermitM /&0/— 0-2ZI5 Occupancy Type: 9 Construction Type: INSTRUCTIONS FOR USE: - • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): roc Enclosed _Partially Enclosed _Open 3. Risk Category: _I Xx II _III _ IV Exposure Category: _B _C roc D 4. Design Wind Velocity 170 mph xX ASD _LRFD End Zone Width: 5•4 ft 5. Mean Roof Height >15 ft Roof Pitch: 2 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +26.4142.0 Zone 2: +26.4F73.1 Zone 3: +26.4/-108.1 Zone 4: *42.0/-0s's Zone 5: +42.0/s6.0 Garage: +36.71-45.4 7. Design Loads: Floor: n/a PSF Roof/Dead: 3.65 PSF - Roof/Live: 20 psf Balcony: me PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: moment frames and cross bracing were used 9. Is A Continuous Load Path Provided? xx Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressul�PSF Soil Test Reports Submitted? Xx Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Allen Wieder, PE 43444 Print Name Cert # & Co. Cert Auth. Wieder Engineering, Inc Signature, Date, and Seal 11718 SE US Hwy 1, Hobe Sound, FL 33455 Company Name &Address _ Revised 07/25/2014 FILE Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Florida Power + Light Security Training Building Project Address: 6501 S. Ocean Drive, Jensen Beach, Florida 34957 Permit #: 1601-0245 Occupancy Type: 'B' Business Construction Type:11B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X 11 _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph _ASD X LRFD End Zone Width: ft S. Mean Roof Height 12 ft Roof Pitch: 1 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 31.11-76.4 Zone 2: 31.1/-128.3 Zone 3: 31.1/193.1 Zone 4: 70.0/-75.8 Zone 5: 70.01-93.1 Garage: 61.1/-75.6 7. Design Loads: Floor: n/a PSF Roof/Dead: 3.65 PSF Roof/Live: 20 Balcony: Na PSF Dock: n/a PSF Deck: n/a PSF .Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: moment frames and X bracing used 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 7 2016 nature, Date, and Seal Niki Norton AR91827 Print Name N2 architecture + design, Inc. Cert # & Co. Cert Auth. 2081 SE Ocean Blvd Suite 1A, Stuart, FL 34996 Revised 07/25/2014 Company Name & Address