Certification for Design Load Compliance
Project Name: FPL Security Training Building
Project Address: (os0/ 5'06171-1 ir£',-AI bP111 `'
PermitM /&0/— 0-2ZI5 Occupancy Type: 9 Construction Type:
INSTRUCTIONS FOR USE: -
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): roc Enclosed _Partially Enclosed _Open
3. Risk Category: _I Xx II _III _ IV Exposure Category: _B _C roc D
4. Design Wind Velocity 170 mph xX ASD _LRFD End Zone Width: 5•4 ft
5. Mean Roof Height >15 ft Roof Pitch: 2 :12 Parapet: n/a ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +26.4142.0 Zone 2: +26.4F73.1 Zone 3: +26.4/-108.1 Zone 4: *42.0/-0s's Zone 5: +42.0/s6.0 Garage: +36.71-45.4
7. Design Loads: Floor: n/a PSF Roof/Dead: 3.65 PSF - Roof/Live: 20 psf Balcony: me PSF
Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
moment frames and cross bracing were used
9. Is A Continuous Load Path Provided? xx Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressul�PSF Soil Test Reports Submitted? Xx Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Allen Wieder, PE 43444
Print Name Cert # & Co. Cert Auth.
Wieder Engineering, Inc
Signature, Date, and Seal 11718 SE US Hwy 1, Hobe Sound, FL 33455
Company Name &Address _
Revised 07/25/2014 FILE
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Florida Power + Light Security Training Building
Project Address: 6501 S. Ocean Drive, Jensen Beach, Florida 34957
Permit #: 1601-0245 Occupancy Type: 'B' Business Construction Type:11B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X 11 _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 170 mph _ASD X LRFD End Zone Width: ft
S. Mean Roof Height 12 ft Roof Pitch: 1 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 31.11-76.4 Zone 2: 31.1/-128.3 Zone 3: 31.1/193.1 Zone 4: 70.0/-75.8 Zone 5: 70.01-93.1 Garage: 61.1/-75.6
7. Design Loads: Floor: n/a PSF Roof/Dead: 3.65 PSF Roof/Live: 20 Balcony: Na PSF
Dock: n/a PSF Deck: n/a PSF .Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF
8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not:
moment frames and X bracing used
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
7 2016
nature, Date, and Seal
Niki Norton AR91827
Print Name
N2 architecture + design, Inc.
Cert # & Co. Cert Auth.
2081 SE Ocean Blvd Suite 1A, Stuart, FL 34996
Revised 07/25/2014
Company Name & Address