Loading...
HomeMy WebLinkAboutGFA SOIL REPORTLL 0 IL rn z w 0 SCANNED V� " - BY MAR 0 7 2016 '�FRNA'ftD�Pv St. Lucie County _ ----------- Laboratory Compaction Characteristics of Soil Using M r roc ASTM D 1557 Project: FPL Security Training Building Project ID: 16-0036.00 Address: 6401 South Ocean Blvd., Jensen Beach Report ID: P-1 Client: Commercial Contracting Division Permit Number: N/A Soil Location: Stockpile Sampled By: K. Thomas Date Sampled: 11/12/2015 Tested By: R. Robinson Date Tested: 11/17/2015 Soil Description: Brown fine sand, trace clay Test Method Used: Method C Preparation Method Used: Dry Type of Rammer: Mechanical As -received Water Content: N/A Specific Gravity: N/A Specific Gravity Test Type: N/A Comments: Sieve Results Sieve Size (mm) Weight Retained Percent Retained 314" 19 N/A N/A 3/8" 9.5 N/A N/A # 4 4.75 N/A N/A Pan 0 N/A N/A 6 7 8 9 10 11 12 13 14 MOISTURE % Dry Density c Moisture 107.1 8.9 108.1 10.3 109.2 11.8 107.9 13.1 Maximum Dry Density (pcf) 109.2 Optimum Moisture (%) 11.8 jeO, e e eMr eo�pl®f 9u l�i ; 171i t6a. 'eo NATIO AL"N�C�� S 493gQ No/ •srt? W m 2116116 W. Moe€, ZE. : c iorlal EnginqirJf&,075' '•Elo7(d� P�. ` Environmental • Geotechnical • Construction Materials Testing • Special 8 Threshold InspeoVons . Florida's Leading Engineering Source wvnv.teamgfaxom kiifi32 L�BdtBtle Compliance GFh �#xsn0�' Pont SL Lucie FBPECA#4930 521 NW EnteTdse DMe Pod St. Lude, R 34986 Phone: Tn.W4-35751 FW.772-924-3580 Soil Nuclear Gauge Report Date: 2/16/2016 Test Method: ASTM D 6938 Client: Commercial Contracting Division 709 SE 5th Street Stuart, FL 34994 project: 16-0036.00 Commercial Contracting Division - Various Projects WEnCHV _ ED MAR 0 7 2016 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. % Remark Test# of Date ProctorlD Method Classification (%) (pef) (%) (pc (in) Compaction 1 1211115 P-1 WA 11.8 109.2 12.6 107.3 12 98 951105 Pass 2 12 I115 P-1 WA 11.8 109.2 11.8 107.9 12 99 95/105 Pass 3 1211/15 P-1 N/A 11.8 109.2 12.5 107.7 12 99 951105 Pass 4 12/1115 P-1 WA 11.8 109.2 12.8 108.3 12 99 95/105 Pass 5 12/9115 1 P-1 N/A 11.8 109.2 12.3 108.1 12 99 95/105 Pass 6 1219115 P-1 WA 11.8 109.2 11.5 107.7 12 99 951105 Pass 7 12/9/15 P-1 NIA 1 11.8 1 109.2 12.9 108.5 12 1 99 95/105 Pass 8 1219115 P-1 NIA 1 11.8 1 109.2 12.0 107.9 12 99 95/ 105 Pass Test Information Gauge Elevation Reference Make freed-, I ow Fte T chnician Test# Test Location Troxler T3440 27974 Thomas, enneln 1 Below Slab Grade: Building Pad, Northeast End 0-1 Troxler T3440 27974 Thomas, Kenneth 2 Below Slab Grade: Building Pad, Northwest End 0-1 Troxler T3440 27974 Thomas, Kenneth 3 Below Slab Grade: Building Pad, Center Area 0-1 4 Below Slab Grade: Building Pad, South Area 0-1 , TroxlerT3440 27974 Thomas, Kenneth 5 Below Slab Grade: Building Pad, Northeast End 1-2 TroxlerT3430 22260 Thomas, Kenneth 6 Below Slab Grade: Building Pad, Northwest End 1 - 2 Troxler T3430 22260 Thomas, Kenneth 7 Below Slab Grade: Building Pad, Center Area 1 - 2 Troxler T3430 22260 Thomas, Kenneth 8 Below Slab Grade: Building Pad, South Area 1 - 2 Troxler T3430 22260 IThomas, Kenneth Remarks Comments Related Tests Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth Is noted as "Backsrader. Gauge calibration data on file with the testing agency. I Test # I Related Test # Test Type_ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 2 �axLuc Port St. Luele FBPE CA # 4930 521 NW Enterprise Drive Port St Lucie, FL M986 Phone: 772-924-35751 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 2/16/2016 Test Method: ASTM D 6938 Client: Commercial Contracting Division 709 SE 5th Street Stuart, FL 34994 Project: 16-0036.00 Commercial Contracting Division -Various Projects Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture % Maximum Dry Density (p In Place Moisture % In Place Dry Density (Pe Probe Depth (in) Percent Compaction Min/Max Comp. % Remark " 9 1/5/16 P-1 N/A 11.8 109.2 11.3 108.2 12 99 95/105 Pass 10 115/16 P-1 N/A 11.8 109.2 11.5 110.0 12 101 95/105 Pass 11 1/5/16 P-1 N/A 11.8 109.2 11.9 109.2 12 100 95/105 Pass 12 115/16 P-1 N/A 11.8 109.2 11.0 108.5 12 99 95/105 Pass 13 1/5/16 P-1 N/A 11.8 109.2 10.7 108.0 12 99 95/105 Pass 14 j 1/5/16 P-1 N/A 11.8 109.2 11.8 109.5 12 100 95 / 105 Pass 15 1/5/16 P-1 N/A 11.8 109.2 - 11.5 109.0 12 100 951105 Pass 16 1/5/16 P-1 N/A 11.8 109.2 10.8 108.7 12 100 95/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 9 Below Footing Grade: Column Pads, East Column Pads North, tat Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 10 Below Footing Grade: Column Pads, East Column Pads North, 2nd Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 11 Below Fooling Grade: Column Pads, East Column Pads South, 3rd Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 12 Below Footing Grade: Column Pads, East Column Pads South, 4th Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 13 Below Footing Grade: Column Pads, West Column Pads North, 1st Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 14 Below Footing Grade: Column Pads, West Column Pads North, 2nd Column from North End 0-1 Troxler T3440 27974 Thomas, Kenneth 15 Beiow Footing Grade: Column Pads, West Column Pads South, 3rd Column from North End10-1 Troxler T3440 27974 Thomas, Kenneth 16 Below Footing Grade: Column Pads, West Column Pads South, 4th Column from North End 0-1 Troxler T3440 27974 IThomas, Kenneth Remarks I Comments Related Tests Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscetter". Gauge calibration data on file with the testing agency. Test # Test # Test Type Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. \N M0� seoeee eNS a p; T5 ° 2/16/201� Dpnald W. Mol er, "CA-1 oil Page 2 of 2 I I 621 NW Entemrise-0rive •Port St Lucie. Florida 34986 . [1I , ■ AM", MAR' 0 7 2016 Laboratory Compaction Characteristics of Soil UsM ASTM D 1557 Project: FPL Security Training Building Project ID: 16-0036.00 Address: 6401 South Ocean Blvd., Jensen Beach Report ID: P-1 Client: Commercial Contracting Division Permit Number: N/A Soil Location: Stockpile Sampled By: K. Thomas Date Sampled: 11/12/2015 Tested By: R. Robinson Date Tested: 11/17/2015 Soil Description: Brown fine sand, trace clay. Test Method Used: Method C Preparation Method Used: Dry Type of Rammer: Mechanical As -received Water Content: N/A Specific Gravity: N/A Specific Gravity Test Type: N/A Comments: Sieve Results Sieve Size:(mm) Weight Retained Percent Retained 3/4" 19 N/A N/A 3/8" 9.5 NIA N/A # 4 4.75 N/A N/A Pan 0 N/A _ N/A 112 111 110 U. CL 109 H 108 z w 107 0 W. 105 104 F 6 7 8 9 10 11 12 13 MOISTURE % Environmental • Geotechnical • Construction Materials Testing • Special & Threshold I Florida's Leading Engineering Source w .teamgfa.com Dry Density c Moisture 107.1 8.9 . 108.1 10.3 109.2 . 11.8 107.9 13.1 Maximum Dry Density (pcf) 109.2 optimum; Moisture (%) 11.8 i SuDtrtmed''s�` . 561. Cr �^. • t11 ._ 2116116_ doler,OPE, ul= I Engine�g75 Jdao` t••. , 13ifae Compliance 0 Pon at Luc,, FBPE CA a 4930 521 NW E.WpA a 00ve von St. Wcb, FL 34%89 Plmn, 7R.924:3575I FW M-924a580' Soil Nudlear Gauge Report Date: 2/16/2016 Test Method: ASTM D 6936' .Client: Commercial Contracting Division 709 SE 5th Street Stuart, FL 34994 Project: , 16-0036.00 - Commercial Contracting Division- Various Projects (I��(� //��l� _ 9U11skL UVE-D MAR 0 7 2pi6 - TesfResults" Test Retest Of Test Date. Proctor iD Method Soil .Classification. Optimum :Moisture 9, Maximum Dry Density in Place Moisture -' /a In Place Dry Density . p - Probe " Depth- • In '.., Percent. compaction MiNMax Comp. . /, Remark 1 1211115 P-1 N/A 11.8 1092, 12.6 107.3. 12 98 951105 Pass 2 7211115 P-1 N/A 11.8 109.2 11.8 107.9 12 99 951105 Pass 3 12lt175 P-1 WA 11.8 109.2 12.5 107.7 12 99 951105 Pass q 12/1/15 P_7 NIA 11.8 109.2 12.8 108.3 12 99 951 105 Pass 5 - 1219/15 P-1 N/A 11.8 1092 12.3 108.1 12. 99951 105 Pass 6 ' -r 1219115 P-1 .. N/A 11:8 1092 11.5 107.7 12. 99. 951405 Pass 7 1219115 P-1 NIA 11.8 109.2 1 12.9 1085 12 99 ;95/105 Pass 8 1219/15 - P-1 WA 11.8 1092 1 12.0 107.9 12 99 95/105 Pass - ' Test Information ' Test# Testtocation .Elevation. Reference Gauge Make/Model I SN Field Technician 1 BelowSlab 'Gmde: Building Pad, Northeast Eno' 0.1 _. .. _ Troxler T3440 27974 ` Thomas, Kenneth 2 . Bet. Slab Gmdo: Building Pad, Northwest End 0-1 Troxler T3440 27974 Thomas, Kenneth 3 Below Slab Grade: Building. Pad, Center Area 0.1 Troxler T3440 27974 Thomas, Kenneth 4 Below Slab Grade: Building Pad, South Area 0-1 Troxler T3440 27974 Thomas, Kenneth 5. Below Slab Grade: Building Pad, Northeast End 1-2 TroxierT343022260 Thomas, Kenneth 6 Below Slab Grade: Building Pad, Northwest End - 1-.2 Trader T3430 22260 Thomas. Kenneth 7 Below Slab Greda: Building Pad, Center Area 1 .2 , . Troxler T3430.22260' Thomas, Kenneth 8 Below Slab Gmde: Building Pad, South Area _ b-2 Troxler T343022260 Thomas, Kenneth Remarks Comments Related Tests Pass: Tests results compty.with spec rations Tests are'Direct Transmission' (Method A) unless probe depth is noted as'Backsraaer'. n.,-,olibratlan data oo ele with the testing agency. Test # I Related Test # F ToatT Test Reports shall not be reproduced,except: in full, Without the written approval of GFA International Inc. Page 1 of 2 0 "N Port St. Wale FBPECA04930 521 NW EntetpOse con Pod St Ludo, FL 34986 Peono: 772-924 n751 Far, M-924458D Soil Nuclear Gauge' Report Date::2/16/2016 Test Methodi ASTM D 6938 Client:. .Project:, , x Commercial Contracting Division 1"036.OD 709 SE Sth Street Commercial Contracting Division - Various Stuart, FL 34994 Projects Test Results - Test q. Retest '- Of, - Test Date ..Proctor ID Method, Soil Classification, Optimum : Moisture % .• Maximum Dry Density. .. p • In Place Moisture e( In Place Dry Density c Probe Depth In .: Percent Compaction •MinfMax Comp. A Remark g 115116 P-1 NIA 11.8 '1092 11.3 108.2 12 ` 99 951105 Pass 10 1151 66 P-1 N/A 11.8 109.2 11.5. 110.0 12 101 951105 Pass 11 1/5116 P-1 NIA 11.8 109.2 11.9 109.2 .12 100 95/105 Pass 12 115116 P-1 WA 11.8 1092 11.0 108.5 12. 99 951105 Pass 13 115116 P-1 , NfA 11:8 109.2 .1D.T 108.0 12 99 951105 Pass .14 - 9i5116 P-1. - �• N/A 11.8. 109,2 11,8 109.5 12 100 95I 105 Pass, 15 1I5116: P-1 WA - 11.8 109.2: 11.5 109.0 12 100 r. 951105 Pass 16 1fy16 P-1 NIA 11.8 109.2 10.8 108.7 12• 100 951105 Pass - Test Information' Test # Test Location .' 'Elevation Reference. Gauge Make/Model ISN Fleld:Techniclan 9 Below Footing Greda:,Column Pads,; East Column Pads North, let Column from North End - 0-1 _ Troxier T3440 27974 Thomas, Kenneth 10 Below, Footing Grade: Column Pads,East. Column Pads North, 2nd Column from North End • 0-1 Troxfer T3440 27974 + Thomas, Kenneth 11 Below Footing Grade: Column Pads; East Column Pads South,.3rd Column from North End 0-1 Troxier T3440 27974 Thomas, Kenneth 12 Below Footing Grade: Column Pads. East Column Pads South, 4111 Column from North End 0. 1 Troxler T3440 27974 _ Thomas, Kenneth 13, - Below. Fooling Grade: Column Pads, West Cclumn cads North, lst Column from North End 0-1 TroxlerT344027974 Thomas, Kenneth 14' '. Below Footing.Gradw Column Pads, West Column Pads North; 2nd Column from North End _. 0-1 ., .. : (. Troxier T3440 27974, ThomaSiXenneth 15 Below Footing Grade: Column Pads. West Column Pads South. 3rd-Column from North End 0 -1. Troxier T3440 27974 . Thomas, Kenneth 16 Below For lingGrode:-Column.Pads, West Column Pads South; 4tii Column from North End e 0 -1 Troxier T3440 27974 Thomas, Kenneth Rernarks� • Comments Related Tests ' Pass: Tests results comply with, specifications Tests are'Dired Transmission' (Mothod A) union pmbo depth is noted as -Bad Ratter-. Gauge calibration dnta on fila with the testing agency. Test N % RB Test N Test Type Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. �PN'gNS Q • - 21162018; -.� . Donald.W: Molar,P& LU Ittt Page 2 of 2 1 I E 521 NW Enterprise Drive • Port St. Lucie, Florida 34966 CONCRETE Project ID: L Project Name: r LV Project Address: C Client Name: CCa Placement Location: No of Samples Cast: Contractor: Ad Mixture: Supplier: Batch Time: Load Size (CY): Total Yards: Mix Designation: Mix Type: Slump (in): Mix Strength (psi): Age1n Days Date Tested Total Load (lbs): Cross Sectional Area (Sq in): Computed Strength (PSI): Fracture Type Security (772) 924-3580 (fax) 'RNATt�aPv LG= 7 ✓1PRESSION STREaF Report ID: 5348-1 Permit NoC: r.Division. Inc. Various Proiects Drive, Jensen Beach - Slab on Time: 7i20AM Cast by GFA: Yes Water Added (Gal): L� Truck No: 25324 �� Ticket No: L 34154714 j Field Tech: Ken Thomas Air Temp, (°F): 46 —� Mix Temp ff): 63 Air Content (%): N/A Unit Weight (PCF): Specimen Size (in): 4s.8l, Field ID: LAB RESULTS 017 28 28 1/2612016 2/16/2016 2/16/2016 3/15/2016 53,270 12.88 —4,140 ' Remarks: Test Method ASTM : C31 1 C39 1 C 143 1 C 172 1 C 173 1 C 1064 Fracture Type Respectfully Submitted: n GFA A tF # 493tional, Inc. C FBPE'A 4930 -. 2/1/2016 Trp,r Trp) Trpe] Typ,4 TrW5 Try,e Donald W. Moler, P.E. Professional Engineer# 60675 Test report shall not be reproduced, except In full, without the written approval of GFA International State of Florida Environmental • Geolechnical T Construction Materials Testing • Special and Threshold Inspections. • Plan Review and Code Compliance Florida's Leading Engineering Source www.teamg%.com I Soil Nuclear Gauge Client: Project: 0,0� Report Date: 8/9/2016 Commercial Contracting Division 16-0036.00 E Test Method:,ASTM D6938: 709 SE 5th Street Commercial Contracting Division - Various Por1S1. Ld, Stuart, FL 34994 Projects FBPECAa4930 521 N Enterprise Drive .Poll St: Ludej FL U986 Phmo: 77M,13575 IF. M-924-0580 Test Results Test#; Retest Of. Test Date. ;LBR-1;L thod Sail Classltieation Optimum. Moisture % Maximum Dry Density _ pe In Place Moisture "h In Place Dry Density pe) - Probe Depth in Percent Com action: Min/Max Comp. %) ,Remark 70 717/1( N/A 11.0 116.0 8.1 114.8 12 99 98/105 Pass Test Information . Test #.. Test Location Elevation Reference Gauge Make I Model I SN Field Technician 70 Subgrade: FPL Security Training Building, 6401 South Ocean Blvd., Jensen Beach - 15' North& 15' West of Northeast Comer of Building. 0-1 Troxler T343036442 Isberner, Todd Remafks Comments- Related Tests Pass: Tests results comply with specifications Tests are'Direct Transmission' (Method A) union probe depth is noted as'Baokseaaer'. Gauge calibration data on file with the testing agency. I Test # I 'Related Test # Test T e A r V'a .; 8/012016 Donald W. Moler, P.E. Pr ftsigrlal Engineer.#,60675 ''. State of Florida ` a - Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1 Digitally signed, printed copies of this document are: not' considered signed and sealed and the signature must be verified on any electronic copies.