HomeMy WebLinkAboutRESPONSESI
2
architecture + design
February 29, 2016
St. Lucie County
Planning + Development Services
Building + Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
RE: Permit Application Number: 1601-0245
Project Number: 15-0159 - FPL Shooting Center
Dear Building Officials,
SCANNED
BY
St. Lucie Countv
Please accept these responses to your conditions of approval:
ADDRESSING ASSIGNMENT
COMPLETE Lydia Galbraith
1/28/16
1/29/16
1/29/16
DOCUMENTS MISSING
PENDING Lashahna Ingram
1/19/2016
NEED MECH/HVAC SUB
1/19/2016
NEED SUB SUMMARY.
1/27/2016
PLUMBING SUB
1/27/2016
FILLED LANDS AFFIDAVIT
1/27/2016
RECORDED NOTICE OF COMMENCEMENT
ENVIRONMENTAL REVIEW
COMPLETE Jennifer Evans
1/26/16
1/26/16
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
FRONT COUNTER REVIEW
COMPLETE Lashahna Ingram
1/19/16
1/19/16
1/19/16
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride
2/8/16
2/8/16
2/8/16
PLANS EXAMINER MECHANICAL
COMPLETE Carl Peterson
2/1/16
2/8/16
2/1/16
PLANS EXAMINER PLUMBING
COMPLETE Greg Smyth
2/2/16
2/2/16
PLANS EXAMINER REVIEW
INCOMPLETE Greg Smyth
2/1/16
2/1/2016 PLS SUMIT A THRID, ORIGINAL SIGNATURED, SEALED AND DATED ENERGY
CALC W/SYSTEM SIZING CALCULATIONS [ NEED A TOTAL OF THREE]
Response: An additional energy calculation has been provided.
2/1/2016 SUBMIT [ 3 ] SETS OF THE METAL BUILDING PLANS IN ORIGINAL FORMAT,
SIGNED, SEALED AND DATED BY RONALD MAYS P.E. * METAL BUILDING
PLANS MUST BE DESIGNED TO THE 2014 FBC NOT THE 2010 AS STATED ON
SHEET C-1 AND F-2 * PLS CHECK ALL PAGES FOR COMPLIANCE WITH THE
2014 FBC ** NIKKI NORTON TO REVIEW AND APPROVE STAMP ALL [ 3 ] SETS
OF THE METAL BUILDING PLANS PRIOR TO RESUBMITTAL * STRUCTURAL
PLANS BY WEIDER ENGINEERING MUST BE DESIGNED TO THE 2014 FLORIDA
BUILDING CODES NOT THE 2010
Response: The metal building plans have now been approved by Weider
Engineering and we have inspected and stamped all (3) sets. The engineers
have corrected the code references on their respective plans.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
2/1/2016 FL#12152 FOR THE DCBI ROLL UP DOORS, AS SHOWN ON THE BUCK STEEL
PLANS, IS NOT AN APPROVED COMPONENT NUMBER UNDER THE 2014 DBPR
PRODUCT APPROVAL REGISTRY * NOA# 14-02032.01 HAS BEEN
SUPERCEEDED FOR THE FIXED WINDOWS * NEED THE PRODUCT APPROVAL
NUMBER FOR ALL SWING DOORS ON PLANS / PLS CORRECT PLANS ***SUBMIT
[ 3 3 ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS COMPLETELY FILLED
OUT, SIGNED, SEALED AND DATED BY YOUR DESIGN PROFESSIONAL
Response: The correct NOAs have now been provided for all exterior swing
doors and exterior roll -up doors. We have prepared a revised affidavit which
you may find on our resubmitted Cover Page on AO. I.
2/1/2016 NEED [ 3 ] ORIGINAL ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD
COMPLIANCE SHEETS " COMPLETELY FILLED OUT AND S.S.D. BY THE PROJECT
DESIGN PROFESSIONAL NIKKI NORTON AR. PLS INCLUDE THE CALCULATED
DESIGN PRESSURES FOR THE OPENINGS W/ OVERHEAD DOORS
Response: Please find that (3) Design Load Compliance Sheets has been
submitted.
2/1/2016 DESIGN PROFESSIONAL OF RECORD TO DO A RAINWATER LAYOUT FOR
DOWNSPOUT LOCATIONS AND SIZES * NOT DESIGNED BY METAL BLDG P.E.
SEE SHEET E-1 * NOT SHOWN ON ELEVATION SHEETS A3.1
Response: Client -requested change order provided by the metal building
fabricator, please see the revised metal building drawings. Additionally, see our
annotations on El regarding the downspout locations and Sheet DET4 for the
Downspout Detail.
2/1/2016 SUBMIT A SEPARATE PERMIT W/ ENGINEERING FOR THE CANVAS EYEBROWS
AROUND THE BUILDING * PLANS STATE BY OTHERS
Response: Canvas eyebrows shall be By Others in a separate permit at a later
date. They are not being installed in the same permit application.
2/1/2016 SUBMIT AN ORIGINAL SIGNED, DATED AND SEALED SOIL REPORT FOR
REVIEW [ KSM 152133-B I
Response: Please find the soils report to be submitted.
2/1/2016 DESIGN PROFESSIONAL TO CHANGE ITEM #1 / SUMMARY OF WORK AO-1 /
PROJECT DESCRIPTION TO THE CORRECT WORK CLASSIFICATION FOR THIS
PROJECT
Response: Please find the Cover Sheet A0.1 to include this correction.
2/1/2016 SUBMIT THE PRODUCT APPROVAL IN TRIPLICATE FOR THE GREENHECK
EXHAUST LOUVERS * MUST MEET THE CRITERIA AS STATED IN FBC
1609.1.2.1 * PLS STATE THE CORRECT MODEL NUMBERS ON M2
Response: Please find the updated Cover Sheet to include this NOA for the
Greenheck Exhaust Louvers.
2/1/2016 DESIGN PROFESSIONAL TO INCLUDE A TABLE ON PLANS IDENTIFYING ALL
GYPSUM BOARD MATERIALS AND ACCESSORIES * INCLUDE A FASTENER
TABLE DESIGNED PER FBC 2508.1 AND CHAPTER 35
2081 SE Ocean Blvd. Suite lA Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Response: The metal building kit is designed with pre -welded connections
from the anchor bolts up, so no additional fasteners are required.
The gypsum board material locations can be found noted upon the plan on A2.1
and correspond to the Wall Type in drawing 2 on this page. 5/8" gypsum
wallboard has been used.
2/8/2016 COMMENTS E-MAILED AS OF THIS DATE
ZONING REVIEW INCOMPLETE Lydia Galbraith 1/27/16
1/27/2016 PLEASE PROVIDE A PERMIT FROM THE HEALTH DEPARTMENT FOR THE
SEPTIC.
Response: The septic permit has been issued as of February 26, 2016.
1/27/2016 PLEASE PROVIDE 3 FLOOR PLANS AND 3 SURVEYS STAMPED BY HEALTH DEP.
FOR APPROVAL.
Response: The Health Department has approved and stamped the floor plans.
1/28/2016 SURVEYS ARE REQUIRED FOR ALL BUILDING PERMITS INVOLVING A PRIMARY
STRUCTURE AND FOR ALL ACCESSORY STRUCTURES WITH A CONSTRUCTION
VALUE EXCEEDING $ 10,000.00. THE SURVEYS ARE REQUIRED TO BE SIGNED
& SEALED BY A REGISTERED FLORIDA SURVEYOR. ALL COPIES ARE
REQUIRED TO BE STAMPED BY THE HEALTH DEPARTMENT IF A SEPTIC
PERMIT IS REQUIRED. PLEASE SEE OUR SURVEY REQUIREMENT SHEET FOR
SPECIFIC REQUIREMENTS.
Response: Please find the (3) surveys to be submitted.
1/28/2016 PLEASE PROVIDE THREE UP TO DATE SIGNED AND SEALED SURVEYS
INDICATING THE PROPOSED BUILDING WITH DIMENSIONS, SETBACK AND
PROPOSED FINISHED FLOOR ELEVATION, ALL EXISTING BUILDINGS AND
PARKING AREA. ELEVATION OF THE CENTER LINE OF THE DRIVEWAYAND
FEMA FLOOD ZONE INFORMATION. THE SURVEY CAN BE A SITE SPECIFIC
SURVEY. THE FRONT MAIN SECURE AREA DOESN'T HAVE TO BE INCLUDED.
Response: Please find the (3) surveys to be submitted.
1/28/2016 A THIRD SET OF MANUAL N'S AND ENERGY CALCS.
Response: Please find the additional energy calculation to be submitted.
1/28/2016 A THIRD SIGNED AND SEALED SET OF THE METAL BUILDING PLANS.
Response: Please find (3) sets of signed & sealed metal building plans.
1/29/2016 IS THE WATER GOING TO BE CITY WATER OR WELL?
Response: The utility connection to the building will be from the City of Fort
Pierce.
1/29/2016 PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING
REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 O: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Please contact our office should you have any further questions.
Cordially,
ik. Norton, R.A.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 O: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
February 29, 2016
St. Lucie County
Planning + Development Services
Building + Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
RE: Permit Application Number: 1601-0245
Project Number: 15-0159 - FPL Shooting Center
Dear Building Officials,
Please accept these responses to your conditions of approval:
ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 1/28/16 1/29/16
DOCUMENTS MISSING
1/19/2016
1/19/2016
1/27/2016
1/27/2016
1/27/2016
ENVIRONMENTAL REVIEW
FIRE DEPARTMENT REVIEW
FRONT COUNTER REVIEW
PLANS EXAMINER ELECTRIC
PENDING Lashahna Ingram
NEED MECH/HVAC SUB
NEED SUB SUMMARY.
PLUMBING SUB
FILLED LANDS AFFIDAVIT
RECORDED NOTICE OF COMMENCEMENT
COMPLETE Jennifer Evans
PENDING Tony Jerger
COMPLETE Lashahna Ingram
COMPLETE Walter Pride
PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson
PLANS EXAMINER PLUMBING COMPLETE Greg Smyth
PLANS EXAMINER REVIEW INCOMPLETE Greg Smyth
1/26/16
1/29/16
1/26/16
1/19/16 1/19/16
1/19/16
2/8/16 2/8/16
2/8/16
2/1/16 2/8/16
2/1/16
2/2/16
2/2/16
2/1/16
2/1/2016 PLS SUMIT A THRID, ORIGINAL SIGNATURED, SEALED AND DATED ENERGY
CALC W/SYSTEM SIZING CALCULATIONS [ NEED A TOTAL OF THREE]
Response: An additional energy calculation has been provided.
2/1/2016 SUBMIT [ 3 ] SETS OF THE METAL BUILDING PLANS IN ORIGINAL FORMAT,
SIGNED, SEALED AND DATED BY RONALD MAYS P.E. * METAL BUILDING
PLANS MUST BE DESIGNED TO THE 2014 FBC NOT THE 2010 AS STATED ON
SHEET C-1 AND F-2 * PLS CHECK ALL PAGES FOR COMPLIANCE WITH THE
2014 FBC ** NIKKI NORTON TO REVIEW AND APPROVE STAMP ALL [ 3 ] SETS
OF THE METAL BUILDING PLANS PRIOR TO RESUBMITTAL * STRUCTURAL
PLANS BY WEIDER ENGINEERING MUST BE DESIGNED TO THE 2014 FLORIDA
BUILDING CODES NOT THE 2010
Response: The metal building plans have now been approved by Weider
Engineering and we have inspected and stamped all (3) sets. The engineers
have corrected the code references on their respective plans.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
2/1/2016 FL#12152 FOR THE DCBI ROLL UP DOORS, AS SHOWN ON THE BUCK STEEL
PLANS, IS NOT AN APPROVED COMPONENT NUMBER UNDER THE 2014 DBPR
PRODUCT APPROVAL REGISTRY * NOA# 14-02032.01 HAS BEEN
SUPERCEEDED FOR THE FIXED WINDOWS * NEED THE PRODUCT APPROVAL
NUMBER FOR ALL SWING DOORS ON PLANS / PLS CORRECT PLANS ***SUBMIT
[ 3 ] ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS COMPLETELY FILLED
OUT, SIGNED, SEALED AND DATED BY YOUR DESIGN PROFESSIONAL
Response: The correct NOAs have now been provided for all exterior swing
doors and exterior roll -up doors. We have prepared a revised affidavit which
you may find on our resubmitted Cover Page on A0.1.
2/1/2016 NEED [ 3 ] ORIGINAL ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD
COMPLIANCE SHEETS " COMPLETELY FILLED OUT AND S.S.D. BY THE PROJECT
DESIGN PROFESSIONAL NIKKI NORTON AR. PLS INCLUDE THE CALCULATED
DESIGN PRESSURES FOR THE OPENINGS W/ OVERHEAD DOORS
Response: Please find that (3) Design Load Compliance Sheets has been
submitted.
2/1/2016 DESIGN PROFESSIONAL OF RECORD TO DO A RAINWATER LAYOUT FOR
DOWNSPOUT LOCATIONS AND SIZES * NOT DESIGNED BY METAL BLDG P.E.
SEE SHEET E-1 * NOT SHOWN ON ELEVATION SHEETS A3.1
Response: Client -requested change order provided by the metal building
fabricator, please see the revised metal building drawings. Additionally, see our
annotations on El regarding the downspout locations and Sheet DET4 for the
Downspout Detail.
2/1/2016 SUBMIT A SEPARATE PERMIT W/ ENGINEERING FOR THE CANVAS EYEBROWS
AROUND THE BUILDING * PLANS STATE BY OTHERS
Response: Canvas eyebrows shall be By Others in a separate permit at a later
date. They are not being installed in the same permit application.
2/1/2016 SUBMIT AN ORIGINAL SIGNED, DATED AND SEALED SOIL REPORT FOR
REVIEW [ KSM 152133-B ]
Response: Please find the soils report to be submitted.
2/1/2016 DESIGN PROFESSIONAL TO CHANGE ITEM #1 / SUMMARY OF WORK AO-1 /
PROJECT DESCRIPTION TO THE CORRECT WORK CLASSIFICATION FOR THIS
PROJECT
Response: Please find the Cover Sheet A0.1 to include this correction.
2/1/2016 SUBMIT THE PRODUCT APPROVAL IN TRIPLICATE FOR THE GREENHECK
EXHAUST LOUVERS * MUST MEET THE CRITERIA AS STATED IN FBC
1609.1.2.1 * PLS STATE THE CORRECT MODEL NUMBERS ON M2
Response: Please find the updated Cover Sheet to include this NOA for the
Greenheck Exhaust Louvers.
2/1/2016 DESIGN PROFESSIONAL TO INCLUDE A TABLE ON PLANS IDENTIFYING ALL
GYPSUM BOARD MATERIALS AND ACCESSORIES * INCLUDE A FASTENER
TABLE DESIGNED PER FBC 2508.1 AND CHAPTER 35
2081 SE Ocean Blvd. Suite lA Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Response: The metal building kit is designed with pre -welded connections
from the anchor bolts up, so no additional fasteners are required.
The gypsum board material locations can be found noted upon the plan on A2.1
and correspond to the Wall Type in drawing 2 on this page. 5/8" gypsum
wallboard has been used.
2/8/2016' COMMENTS E-MAILED AS OF THIS DATE
ZONING REVIEW INCOMPLETE Lydia Galbraith 1/27/16
1/27/2016 PLEASE PROVIDE A PERMIT FROM THE HEALTH DEPARTMENT FOR THE
SEPTIC.
Response: The septic permit has been issued as of February 26, 2016.
1/27/2016 PLEASE PROVIDE 3 FLOOR PLANS AND 3 SURVEYS STAMPED BY HEALTH DEP.
FOR APPROVAL.
Response: The Health Department has approved and stamped the floor plans.
1/28/2016 SURVEYS ARE REQUIRED FOR ALL BUILDING PERMITS INVOLVING A PRIMARY
STRUCTURE AND FOR ALL ACCESSORY STRUCTURES WITH A CONSTRUCTION
VALUE EXCEEDING $ 10,000.00. THE SURVEYS ARE REQUIRED TO BE SIGNED
& SEALED BY A REGISTERED FLORIDA SURVEYOR. ALL COPIES ARE
REQUIRED TO BE STAMPED BY THE HEALTH DEPARTMENT IF A SEPTIC
PERMIT IS REQUIRED. PLEASE SEE OUR SURVEY REQUIREMENT SHEET FOR
SPECIFIC REQUIREMENTS.
Response: Please find the (3) surveys to be submitted.
1/28/2016 PLEASE PROVIDE THREE UP TO DATE SIGNED AND SEALED SURVEYS
INDICATING THE PROPOSED BUILDING WITH DIMENSIONS, SETBACK AND
PROPOSED FINISHED FLOOR ELEVATION, ALL EXISTING BUILDINGS AND
PARKING AREA. ELEVATION OF THE CENTER LINE OF THE DRIVEWAYAND
FEMA FLOOD ZONE INFORMATION. THE SURVEY CAN BE A SITE SPECIFIC
SURVEY. THE FRONT MAIN SECURE AREA DOESN'T HAVE TO BE INCLUDED.
Response: Please find the (3) surveys to be submitted.
1/28/2016 A THIRD SET OF MANUAL N'S AND ENERGY CALCS.
Response: Please find the additional energy calculation to be submitted.
1/28/2016 A THIRD SIGNED AND SEALED SET OF THE METAL BUILDING PLANS.
Response: Please find (3) sets of signed & sealed metal building plans.
1/29/2016 IS THE WATER GOING TO BE CITY WATER OR WELL?
Response: The utility connection to the building will be from the City of Fort
Pierce.
1/29/2016 PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING
REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Please contact our office should you have any further questions.
Cordially,
iki L. orton, R.A.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
February 29, 2016
St. Lucie County
Planning + Development Services
Building + Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
RE: Permit Application Number: 1601-0245
Project Number: 15-0159 — FPL Shooting Center
Dear Building Officials,
Please accept these responses to your conditions of approval:
ADDRESSING ASSIGNMENT
COMPLETE Lydia Galbraith
1/28/16
1/29/16 1/29/16
DOCUMENTS MISSING
PENDING Lashahna Ingram
1/19/2016
NEED MECH/HVAC SUB
1/1912016
NEED SUB SUMMARY.
1/27/2016
PLUMBING SUB
1/27/2016
FILLED LANDS AFFIDAVIT
1/27/2016
RECORDED NOTICE OF COMMENCEMENT
ENVIRONMENTAL REVIEW
COMPLETE Jennifer Evans
1/26/16 1/26/16
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
FRONT COUNTER REVIEW
COMPLETE Lashahna Ingram
1/19/16
1/19/16 1/19/16
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride
2/8/16
2/8/16 2/8/16
PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson
2/1/16
2/8/16 2/1/16
PLANS EXAMINER PLUMBING
COMPLETE Greg Smyth
2/2/16 2/2/16
PLANS EXAMINER REVIEW
INCOMPLETE Greg Smyth
2/1/16
2/1/2016 PLS SUMIT A THRID, ORIGINAL SIGNATURED, SEALED AND DATED ENERGY
CALC W/SYSTEM SIZING CALCULATIONS [ NEED A TOTAL OF THREE]
Response: An additional energy calculation has been provided.
2/1/2016 SUBMIT [ 3 ] SETS OF THE METAL BUILDING PLANS IN ORIGINAL FORMAT,
SIGNED, SEALED AND DATED BY RONALD MAYS P.E. * METAL BUILDING
PLANS MUST BE DESIGNED TO THE 2014 FBC NOT THE 2010 AS STATED ON
SHEET C-1 AND F-2 * PLS CHECK ALL PAGES FOR COMPLIANCE WITH THE
2014 FBC ** NIKKI NORTON TO REVIEW AND APPROVE STAMP ALL [ 3 ] SETS
OF THE METAL BUILDING PLANS PRIOR TO RESUBMITTAL * STRUCTURAL
PLANS BY WEIDER ENGINEERING MUST BE DESIGNED TO THE 2014 FLORIDA
BUILDING CODES NOT THE 2010
Response: The metal building plans have now been approved by Weider
Engineering and we have inspected and stamped all (3) sets. The engineers
have corrected the code references on their respective plans.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
2/1/2016 FL#12152 FOR THE DCBI ROLL UP DOORS, AS SHOWN ON THE BUCK STEEL
PLANS, IS NOT AN APPROVED COMPONENT NUMBER UNDER THE 2014 DBPR
PRODUCT APPROVAL REGISTRY * NOA# 14-02032.01 HAS BEEN
SUPERCEEDED_ FOR THE FIXED WINDOWS * NEED THE PRODUCT APPROVAL
NUMBER FOR ALL SWING DOORS ON PLANS / PLS CORRECT PLANS ***SUBMIT
[ 3 ] ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS COMPLETELY FILLED
OUT, SIGNED, SEALED AND DATED BY YOUR DESIGN PROFESSIONAL
Response: The correct NOAs have now been provided for all exterior swing
doors and exterior roll -up doors. We have prepared a revised affidavit which
you may find on our resubmitted Cover Page on A0.1.
2/1/2016 NEED [ 3 ] ORIGINAL ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD
COMPLIANCE SHEETS " COMPLETELY FILLED OUT AND S.S.D. BY THE PROJECT
DESIGN PROFESSIONAL NIKKI NORTON AR. PLS INCLUDE THE CALCULATED
DESIGN PRESSURES FOR THE OPENINGS W/ OVERHEAD DOORS
Response: Please find that (3) Design Load Compliance Sheets has been
submitted.
2/1/2016 DESIGN PROFESSIONAL OF RECORD TO DO A RAINWATER LAYOUT FOR
DOWNSPOUT LOCATIONS AND SIZES * NOT DESIGNED BY METAL BLDG P.E.
SEE SHEET E-1 * NOT SHOWN ON ELEVATION SHEETS A3.1
Response: Client -requested change order provided by the metal building
fabricator, please see the revised metal building drawings. Additionally, see our
annotations on ES regarding the downspout locations and Sheet DET4 for the
Downspout Detail.
2/1/2016 SUBMIT A SEPARATE PERMIT W/ ENGINEERING FOR THE CANVAS EYEBROWS
AROUND THE BUILDING * PLANS STATE BY OTHERS
Response: Canvas eyebrows shall be By Others in a separate permit at a later
date. They are not being installed in the same permit application.
2/1/2016 SUBMIT AN ORIGINAL SIGNED, DATED AND SEALED SOIL REPORT FOR
REVIEW [ KSM 152133-B ]
Response: Please find the soils report to be submitted.
2/1/2016 DESIGN PROFESSIONAL TO CHANGE ITEM #1 / SUMMARY OF WORK AO-1 /
PROJECT DESCRIPTION TO THE CORRECT WORK CLASSIFICATION FOR THIS
PROJECT
Response: Please find the Cover Sheet AO.1 to include this correction.
2/1/2016 SUBMIT THE PRODUCT APPROVAL IN TRIPLICATE FOR THE GREENHECK
EXHAUST LOUVERS * MUST MEET THE CRITERIA AS STATED IN FBC
1609.1.2.1 * PLS STATE THE CORRECT MODEL NUMBERS ON M2
Response: Please find the updated Cover Sheet to include this NOA for the
Greenheck Exhaust Louvers.
2/1/2016 DESIGN PROFESSIONAL TO INCLUDE A TABLE ON PLANS IDENTIFYING ALL
GYPSUM BOARD MATERIALS AND ACCESSORIES * INCLUDE A FASTENER
TABLE DESIGNED PER FBC 2508.1 AND CHAPTER 35
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Response: The metal building kit is designed with pre -welded connections
from the anchor bolts up, so no additional fasteners are required.
The gypsum board material locations can be found noted upon the plan on A2.1
and correspond to the Wall Type in drawing 2 on this page. 5/8" gypsum
wallboard has been used.
2/8/2016 COMMENTS E-MAILED AS OF THIS DATE
ZONING REVIEW INCOMPLETE Lydia Galbraith 1/27/16
1/27/2016 PLEASE PROVIDE A PERMIT FROM THE HEALTH DEPARTMENT FOR THE
SEPTIC.
Response: The septic permit has been issued as of February 26, 2016.
1/27/2016 PLEASE PROVIDE 3 FLOOR PLANS AND 3 SURVEYS STAMPED BY HEALTH DEP.
FOR APPROVAL.
Response: The Health Department has approved and stamped the floor plans.
1/28/2016 SURVEYS ARE REQUIRED FOR ALL BUILDING PERMITS INVOLVING A PRIMARY
STRUCTURE AND FOR ALL ACCESSORY STRUCTURES WITH A CONSTRUCTION
VALUE EXCEEDING $ 10,000.00. THE SURVEYS ARE REQUIRED TO BE SIGNED
& SEALED BY A REGISTERED FLORIDA SURVEYOR. ALL COPIES ARE
REQUIRED TO BE STAMPED BY THE HEALTH DEPARTMENT IF A SEPTIC
PERMIT IS REQUIRED. PLEASE SEE OUR SURVEY REQUIREMENT SHEET FOR
SPECIFIC REQUIREMENTS.
Response: Please find the (3) surveys to be submitted.
1/28/2016 PLEASE PROVIDE THREE UP TO DATE SIGNED AND SEALED SURVEYS
INDICATING THE PROPOSED BUILDING. WITH DIMENSIONS, SETBACK AND
PROPOSED FINISHED FLOOR ELEVATION, ALL EXISTING BUILDINGS AND
PARKING AREA. ELEVATION OF THE CENTER LINE OF THE DRIVEWAYAND
FEMA FLOOD ZONE INFORMATION. THE SURVEY CAN BE A SITE SPECIFIC
SURVEY. THE FRONT MAIN SECURE AREA DOESN'T HAVE TO BE INCLUDED.
Response: Please find the (3) surveys to be submitted.
1/28/2016 A THIRD SET OF MANUAL N'S AND ENERGY CALCS.
Response: Please find the additional energy calculation to be submitted.
1/28/2016 A THIRD SIGNED AND SEALED SET OF THE METAL BUILDING PLANS.
Response: Please find (3) sets of signed & sealed metal building plans.
1/29/2016 IS THE WATER GOING TO BE CITY WATER OR WELL?
Response: The utility connection to the building will be from the City of Fort
Pierce.
1/29/2016 PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING
REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
2081 SE Ocean Blvd. Suite lA Stuart, Florida 34996 O: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
Please contact our office should you have any further questions.
Cordially,
i L. rton, R.A.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 O: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
E
1
architecture + design
March 16, 2016
St. Lucie County MAR 19 20%
Planning + Development Services
Building + Code Regulation Division p:dFe4IITTING
2300 Virginia Avenue St. Luc: ",Iray, FL
Fort Pierce, FL 34982
RE: Permit Application Numbe
Project Number: 15-0159 — FPLF:Sffbbflng center
Dear Building Officials,
MAR 18 RECD
Please accept these responses to your conditions of approval:
ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 1/28/16 1/29/16 1/29/16
DOCUMENTS MISSING PENDING Lashahna Ingram
1/27/2016 FILLED LANDS AFFIDAVIT
ENVIRONMENTAL REVIEW COMPLETE Jennifer Evans 1/26/16 1/26/16
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 1/19/16 1/19/16 1/19/16
PE REVIEW COMMENTS (21 INCOMPLETE Joe Cicio 3/7/16
3/7/16 THE SOIL TEST FROM KSM STATES THAT THE ALLOWABLE SOIL BEARING PRESSURE
IS 2000 P.S.F. OR LESS / PLANS ARE DESIGNED TO 2500 P.S.F. * EITHER MODIFY
SOIL REPORT OR RE -DESIGN THE PLANS * COMMENT ENERATED AFTER REVIEW OF
THE SOIL REPORT AS SUBMITTED W/PACKAGE ON 2/29/16
RESPONSE: Please refer to the attached Revised Sheet 52.0. Note #3 under the
"Foundation" section of notes has been revised and clouded to state that the
foundation has been designed to meet the 2,000 psf soil bearing pressure. In
addition, Note #1 sites the Geotechnical Report which was used to assist in
the design of the foundation.
3/7/16 THE PRODUCT REVIEW AFFIDAVITS ARE INCOMPLETE AS DESIGNED ON PLAN SHEET
A0.1 * PREVIOUS COMMENT CALLED FOR THE ST LUCIE COUNTY PRODUCT
AFFIDAVIT WHICH INCUDES ALL DESIGN PRESSURES AND ALL MEATHODS OF
ATTACHMENT FOR ALL BUILDINNG CLADDING [ DOORS, WINDOWS ETC]
RESPONSE: The Product Approval Affidavit has been revised and included on the Cover
Sheet (AO.1). The St. Lucie County form has been added to the drawing in
CAD format. Items that have been specified by the Architect have been listed
along with design pressures and attachment methods. Refer to remaining
items within the metal building shop drawings prepared by Buck Steel Inc.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 O: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
0
I
2
architecture + design
PLANS EXAMINER ELECTRIC
COMPLETE
Walter Pride
PLANS EXAMINER MECHANICAL COMPLETE
Carl Peterson
PLANS EXAMINER PLUMBING
COMPLETE
Greg Smyth
PLANS EXAMINER REVIEW
COMPLETE
Greg Smyth
ZONING REVIEW
COMPLETE
Lydia Galbraith
2/8/16
2/8/16
2/8/16
2/1/16
2/8/16
2/1/16
2/2/16
2/2/16
2/1/16
3/7/16
3/7/16
1/27/16
3/7/16
3/7/16
Please contact our office should you have any further questions.
Cordially,
r -
NW . Norton, R.A.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
March 16, 2016
St. Lucie County
Planning + Development Services
Building + Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
RE: Permit Application Number: 1601-0245
Project Number: 15-0159 - FPL Shooting Center
Dear Building Officials,
Please accept these responses to your conditions of approval:
ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 1/28/16 1/29/16 1/29/16
DOCUMENTS MISSING PENDING Lashahna Ingram
1/27/2016 FILLED LANDS AFFIDAVIT
ENVIRONMENTAL REVIEW COMPLETE Jennifer Evans 1/26/16 1/26/16
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 1/19/16 1/19/16 1/19/16
PE REVIEW COMMENTS (2) INCOMPLETE Joe Cicio 3/7/16
3/7/16 THE SOIL TEST FROM KSM STATES THAT THE ALLOWABLE SOIL BEARING PRESSURE
IS 2000 P.S.F. OR LESS / PLANS ARE DESIGNED TO 2500 P.S.F. * EITHER MODIFY
SOIL REPORT OR RE -DESIGN THE PLANS * COMMENT ENERATED AFTER REVIEW OF
THE SOIL REPORT AS SUBMITTED W/PACKAGE ON 2/29/16
RESPONSE: Please refer to the attached Revised Sheet S2.0. Note #3 under the
"Foundation" section of notes has been revised and clouded to state that the
foundation has been designed to meet the 2,000 psf soil bearing pressure. In
addition, Note #1 sites the Geotechnical Report which was used to assist in
the design of the foundation.
3/7/16 THE PRODUCT REVIEW AFFIDAVITS ARE INCOMPLETE AS DESIGNED ON PLAN SHEET
A0.1 * PREVIOUS COMMENT CALLED FOR THE ST LUCIE COUNTY PRODUCT
AFFIDAVIT WHICH INCUDES ALL DESIGN PRESSURES AND ALL MEATHODS OF
ATTACHMENT FOR ALL BUILDINNG CLADDING [ DOORS, WINDOWS ETC]
RESPONSE: The Product Approval Affidavit has been revised and included on the Cover
Sheet (A0.1). The St. Lucie County form has been added to the drawing in
CAD format. Items that have been specified by the Architect have been listed
along with design pressures and attachment methods. Refer to remaining
items within the metal building shop drawings prepared by Buck Steel Inc.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853
2
architecture + design
PLANS EXAMINER ELECTRIC
COMPLETE
Walter Pride
PLANS EXAMINER MECHANICAL COMPLETE
Carl Peterson
PLANS EXAMINER PLUMBING
COMPLETE
Greg Smyth
PLANS EXAMINER REVIEW
COMPLETE
Greg Smyth
ZONING REVIEW
COMPLETE
Lydia Galbraith
2/8/16
2/8/16
2/8/16
2/1/16
2/8/16
2/1/16
2/2/16
2/2/16
2/1/16
3/7/16
3/7/16
1/27/16
3/7/16
3/7/16
Please contact our office should you have any further questions.
Niki L. Norton, R.A.
2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 0: (772) 220-4411
www.n2archdesign.com Lic# AA26002853