HomeMy WebLinkAboutCETIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SCANN
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553St tuCl@
County
rtq"I t�inQ for Design Load Compliance
Project Name: Family Doll Wall Sign
Project address: 10331 SE Lennard Rd. Port St Lucie, FL 34952
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single mrmulti-family)
o Residential Addition
o Any accessory structure requiring a building permit
Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 2oL 14 Supplements using ASCE 7-30
2. Structure Designed as (check one): N/A Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _111 _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft
5. Mean Roof Height 20R ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:+37.4 Zone 2: -46.9 Zone 3: Zone 4: Zone S: Garage:
7. Design Loads: Floor. PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? Yes _XNot Applicable Explain Why Not:
Monument Sign
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
I DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I`jotptfifylthat structural elements depicted on these plans provide adequate resistance to the design
force�$p fi®.;Z(LB9s�i/� PF "?-7-/
'tc�sF''.,y �. rTG/ Q/2/LL36YS/i
No 50221 * Print Name Cert # & Co. Cert Auth.
Sigry;re, DatUMOGEal i ��: �IPa.Q C!!rW4dF_5 i</t/B B/lSTiitwl '� .329rv8
%� C�.�•.LOR�O?: ���\� Company Name & Address
`
Revised 0S•