Loading...
HomeMy WebLinkAboutCETIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SCANN Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553St tuCl@ County rtq"I t�inQ for Design Load Compliance Project Name: Family Doll Wall Sign Project address: 10331 SE Lennard Rd. Port St Lucie, FL 34952 Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single mrmulti-family) o Residential Addition o Any accessory structure requiring a building permit Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 2oL 14 Supplements using ASCE 7-30 2. Structure Designed as (check one): N/A Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _111 _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: ft 5. Mean Roof Height 20R ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:+37.4 Zone 2: -46.9 Zone 3: Zone 4: Zone S: Garage: 7. Design Loads: Floor. PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes _XNot Applicable Explain Why Not: Monument Sign 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes I DESIGN PROFESSIONAL CERTIFICATION STATEMENT: 1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I`jotptfifylthat structural elements depicted on these plans provide adequate resistance to the design force�$p fi®.;Z(LB9s�i/� PF "?-7-/ 'tc�sF''.,y �. rTG/ Q/2/LL36YS/i No 50221 * Print Name Cert # & Co. Cert Auth. Sigry;re, DatUMOGEal i ��: �IPa.Q C!!rW4dF_5 i</t/B B/lSTiitwl '� .329rv8 %� C�.�•.LOR�O?: ���\� Company Name & Address ` Revised 0S•