HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1553
for Design Load Compliance
Project Name: Family Dollar
Project Address: 10331 SE Lennard Rd. Port St. Lucie, FL 34952
Permit #:
Type: Construction Type:
SCANNED
BY
St. Luce Countt,
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies far commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessary structure requiring a building permit
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 2014 Supplements using ASCE 7-10
2.
Structure Designed as (check one):
WA Enclosed _Partially Enclosed
_Open
3.
Risk Category: X I _II _III
_IV Exposure Category: _B X
C _D
4.
Design Wind Velocity 150
mph ASD X LRFD End Zone Width:
ft
S.
Mean Roof Height 10ft
ft Roof Pitch: 712 Parapet:
ft
6.
Components & Cladding Design Pressures Used: (PSF, based an 10sgft @ 15'MRH, dearly label an all plan openings):
Zone 1: +34.5 Zone 2:
Zone 3: Zone 4: Zone 5:
Garage:
7.
Design Loads: Floor. PSF
Roof/Dead: PSF Roof/Live:
Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not:
Monument Sign
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not
10. Design Sail Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I al i?�ggrft t t structural elements depicted on these plans provide adequate resistance to the design
forces s*0edaIZl(e9So��� n PE et(ooza/
.��: •'��ceNSF'••.'S• �. �TL/ �I l2/C-B�frf G'e�A !�• � /�H
* Print Name Cert # & Co. Cert Auth.
Q' No.60221
P200SSi✓E Ei,tlsl�/EE.2ir�Cr �SE2vie�S LLG
hY� X�
Sigrig 'rDatI ;' t(/� /6e CAWOZ -s 4t/_ SESAST/Qs/. 01:1— 329s41
r . PLOR10P.•'' _: Company Name &Address
Revised 07%35 AL � o
.19*
D
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project
Project Address: 10331 SE Lennard Rd. Port St. Lucie, FL 34952
Permit#: Occupancy Type: Construction
,(TANNED
BY
St Luce Countv
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): WA Enclosed _Partially Enclosed Open
3. Risk Category: X—' _II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 750 mph ASD X LRFD End Zone Width: ft
S. Mean Roof Height 10ft ft Roof Pitch: :12 Parapet: fit
6. Components & Gadding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +34.5 Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor. PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not:
Monument Sign
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces spe``ARM I I I I I I I 1 I//// PE tl-6022/
�P, QI..... 9 /I >�1 L/ �)!Z/LE+g�N ee�A 46- d2& leH
Q�,• ' �tOFNs@ '• sf Print Name Cert # & Co. Cert Auth.
^No. 60221 P0,060�Ssi✓E Ei�rl9l�lEsE2viers LLG
Ap e•At �A A!i -�
ati Date, and Sella (Zg�w ` /0� C1H4+2G6S .�Ft/_ SESaSTiA�✓. �L 3295'd�
�Q� •. STATE OF : •�lV� Company Name & Address
i; fiVAI-I;t��