HomeMy WebLinkAboutMISC EMAILSJoe Cicio From: Sent: To: Cc: Subject: Good afternoon Mr. Hart P.E, Joe Cicio Friday, July 08, 2016 1:31 PM 'Adam Hart' 'gene'; Joe Cicio; Carl John Peterson RE: Coastal Floors Project SUANN- St. Luce Crnlnfi I asked the contractor to meet with me this morning regarding some issues that were still incomplete or not corrected on the revised plans designed by yourself as the second design professional on this job . Mr. Gene Santoro of Coastal Construction has a partial list of what is still needed or needs to be corrected starting with the delegated engineering being reviewed by you and approved via an approval stamp on the plans. The barjoist plans are still in a preliminary state and are stated hot for construction on said un-sealed plans . The stack of product approval paperwork can be eliminated with our product review affidavits being completely filled out then signed, sealed and dated by you as the design professional of record including all methods of attachment thus making everyone's task more efficient including our inspectors. We can accept the product approvals as long as all tables, methods of attachment, design pressures etc: are tagged for compliance then all product approvals must be approved by you via your approval stamp so that we know that you have accepted this cladding to be used in your building designs. There are still references to the Florida Residential Code in the plans with reference to the residential pressure table,R301.2 . Commercial buildings design from ASCE7-10 criteria for all pressures and must be indicated on the plans . There is also a reference in the wind table that this is a single family dwelling. With all of these items still open it is difficult to perform a full review and will await a re -submittal from Mr. Santoro to perform a complete final review. Thank You Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner StL-azie.Co-ww FLa.awui/" a*.d/DewAo�Serv,.c From: hrcdesigns@gmaii.com [mailto:hrcdesigns@gmail.com] On Behalf Of Adam Hart Sent: Friday, July 08, 2016 12:25 PM To: Joe Cicio <cicioj@stlucieco.org> Subject: Coastal Floors Project ij. Mr. Clcio, I received a message today regarding the permit documents for the Coastal Floors project. I would like to speak to you directly if possible about these drawings and your feedback to the Client. We feel that we have provided everything as required to proceed with this permit and we would like to know exactly what you feel is lacking in the package that we have been trying to submit to your office so that we can address this immediately. Please let me know if there is a time I can reach out to you on the phone this afternoon. Thank you in advance for your help on this. Attached you will find a copy of the comment responses we submitted for your reference. Adam Hart, PE HRC Designs PO Box 2999 Stuart, F134995 772-215-8521 ahart@hrcdesigns.co www.hrcdesigns.com Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. F3[ ENGINEERS O SURVEYORS December 13, 2017 Joseph M. Cicio Plans Examiner oil SCANNEL, BY St. Lucia CdUntt St. Lucie County Planning and Development Services 2300 Virginia Avenue Fort Pierce, FL 34982 RE: Coastal Floor and Granite - SLC-1511-0282 Building Sewer Line Certification Mr. Cicio, File # 15-256 On behalf of the applicant, please accept this letter and the enclosed documents as a professional engineer's certification for 203 linear feet of gravity sewer running from the building to the Port St. Lucie Utility Systems Department point of service at the property line. The gravity sewer service has been constructed in substantial conformance with the approved engineering plans. All construction was observed and inspected by myself or those under my director supervision. Please see the enclosed as -built survey for your consideration. Should you have any questions or require additional information, please feel free to contact me at 772-462-2455 or by e-mail at davidbaggett(a)edc-inc.com at your convenience. Since David C. Baggett, P.E. Professional Engineer Florida Licenses No. 81375 RJK/dcb w/enclosures ai * !N0.81375 ��0 STATE OF :"�� .�� cc: Nick Elliott— Palm Park Center, LLc fil ll1I project file #15-256 \\SERVER\EDC-Shared\EDC-Fort-Pierce\15-projects\15-256(Elliott_Property-Coastal_Flooring)\SLC\Project Certification\Coastal_Floor SLC_Bldg_Sewer Line_Cert12-13-17.docc ENGINEERING DESIGN & CONSTRUCTION, INC CIVIL ENGINEERS & SURVEYORS SPECIALIZING IN LAND DEVELOPMENT 10250 SW Village Parkway, Suite 201 Part St. Lucie, FL 34987 772-462-2455 Coastal Development Corporation OUMIVI EG -�f L BY 8569 South Highway 1 ccieCOunty Port St Lucie, Florida 34952 St Lucie County Building Department RE: Permit No. 1511-0282 May 11, 2016 To Whom It May Concern: Please find enclosed the plan revisions requested from your collective review in December, 2015. As you may be aware, the original site engineer of record, Joe Friscia of Friscia Engineering expired. We were required to engage another engineer, EDC of Ft. Piercewho acquired the practice, to complete this project. Unfortunately, this necessitated starting over again to obtain the necessary FDOT permits and design drawings in the new engineer's name. Site Plans, etc.: Completed documents include the site plan, FDOT permits SFWMD permits, City of Port St. Lucie Utilities Agreement, and connection permits, and so on. We are pending the FDOT Driveway connection. These should be ready next week. The engineer told me yesterday that the local FDOT office received the documents from the Ft. Lauderdale office yesterday, and will be submitted separately. Submitted items included are: Mechanical Review Plan and Required calculation documents attached (3 sets) NOA's As necessary, and also listed on plans Plan review comments updates and an original signed and sealed soils reports. Sub List attached (3 sets):A and M Engineering Original soils report signed and sealed and two copies, ( 3 copies) ERD Staff: Environmental documents addressing the turtles and vegetation have been previously adjudicated by submission of documents from Crossroads Environmental Services Plumbing Comments: Comments completed and on plans Zoning Review: 3 Copies of the PSL utilities Agreement 3 sets of Site plans and the FDOT driveway Permit should be submitted by mid -May, when received Thank You, Gene Santoro RECEIVED MAY 11 2016 Joe Cicio From: Diana Spriggs <DSpriggs@cityofpsl.com> Sent: Thursday, December 21, 2017 2:51 PM To: Joe Cicio; David Baggett Cc: Project File; Laney Southerly; nick@coastalflooring.net; Sam Trotter, 'Gene' Subject: RE: 5112: RE: Coastal Floor Turnover documents PSLUSD is satisfied with all requirements for sewer service for this project If you have any questions, please let me know Thank you, SCANNED Diana Spriggs, P.E. BY Project Manager St. Lucie counts, City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772) 807-4452 From: David Baggett [mailto:davidbaggett@edc-inc.com] Sent: Thursday, December 21, 2017 9:59 AM To: Diana Spriggs <DSpriggs@cityofpsl.com>; Joe Cicio <cicioj@stlucieco.org> Cc: Project File <ProjectFile@cityofpsl.com>; Laney Southerly <LSoutherly@cityofpsl.com>; nick@coastaIflooring.net; Sam Trotter <sa mtrotte r@edc-i nc.com>; 'Gene' <Gene@coastaldevelopmentcorp.com> Subject: RE: 5112: RE: Coastal Floor Turnover documents Diana, barring anything unforeseen it looks like we have provided what we need for utilities. Joe Cicio at the county is leaving for vacation at the end of the week. The owner is hoping to be able to provide him with PSLUSD's clearance before then. Do you have any projection on when you would be able to provide this? Please let me know if I can assist in anyway Thank you very much 'David C. Baggett, P.E. Project Engineer rFe�rca ctsuaver Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 n 772-462-2455, ext 113 8 772-408-4208 ® davidbaggett(c edc-inc.com From: Diana Spriggs Fmailto:DSpriqqs@)cityofpsl.com] Sent: Wednesday, December 20, 2017 2:34 PM To: David Baggett Cc: Project File; Laney Southerly; nick(@coastalflooring.net; Sam Trotter; 'Gene' Subject: RE: 5112: RE: Coastal Floor Turnover documents Looks good. Thank you. From: David Baggett [mailto:davidbaggett@edc-inc.com] Sent: Wednesday, December 20, 2017 2:32 PM To: Diana Spriggs <DSpriggs@citvofpsl.com> Cc: Project File <ProiectFile@cityofpsl.com>; Laney Southerly <LSoutherly@cityofpsI=>; nick coastalflooring.net; Sam Trotter <samtrotter@edc-inccom>; 'Gene' <Gene@coasta[develop mentcorp.com> Subject: RE: 5112: RE: Coastal Floor Turnover documents Revised as requested. Thankyou David C. Baggett, P.E. Project Engineer E �!23 Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 772-462-2455, ext 113 A 772-408-4208 �R davidbaaoett(a)edc-inc.com From: Diana Spriggs[mailto:DSprygs(a)cityofpsi.com] Sent: Wednesday, December 20, 2017 2:22 PM To: David Baggett Cc: Project File; Laney Southerly; nick(dcoastalfloorina.net; Sam Trotter; 'Gene' Subject: RE: 5112: RE: Coastal Floor Turnover documents Please revise the deviation to state "approximately 23 linear feet shorter" Thank you, Diana Spriggs, P.E. Project Manager City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772) 807-4452 From: David Baggett [mailto:davidbaggett@edc-inccom] Sent: Wednesday, December 20, 2017 2:06 PM To: Diana Spriggs <DSpriggs@citvofpsl.com> Cc: Project File <ProiectFile@citvofpsl.com>; Laney Southerly <LSoutherly@citvofpsl.com>; nick@coastalflooring.net; Sam Trotter <samtrotter@edc-inc.com>; 'Gene' <Gene@coastaldevelopmentcorp.com> Subject: RE: 5112: RE: Coastal Floor Turnover documents Diana, see attached revised cert form with explanation on the shorter 6" sanitary lines. Hardcopies and disc of survey are being dropped off this afternoon. Thank you David C. Baggett, P.E. Project Engineer cxcv�eEas asuasrroaa Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 M 772-462-2455, ext 113 A 772-408-4208 � davidbaggetta?edc-inc.com From: Diana Spriggs[mailto:DSpriggsCcbcityofpsl.coml Sent: Wednesday, December 20, 2017 10:13 AM To: David Baggett Cc: Project File; Laney Southerly; nickCcbcoastalfloorino.net; Sam Trotter; 'Gene' Subject: RE: 5112: RE: Coastal Floor Turnover documents Please provide a deviation explanation on the second page of the Certification form for explanation of the change in constructed length of 6" Sanitary that we will own. Any pipe or item quantity change greater than 10% requires an explanation. As soon as this revised form is received along with a hard copy of the As-builts signed and sealed and the AutoCAD file of the as-builts we can issue the permit certification and send our clearance to Saint Lucie County. Thank you, Diana Spriggs, P.E. Project Manager City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772)807-4452 From: David Baggett [mailto:davidbaggett@edc-inc.coml Sent: Tuesday, December 19, 2017 5:56 PM To: Diana Spriggs <DSpriggs@citvofpsl.com> Cc: Project File <ProiectFile@citvofpsl.com>; Laney Southerly <LSoutherly@cityofpsl.com>; nick@coastalflooring.net; Sam Trotter <samtrotter@edc-inc.com>; 'Gene' <Gene@coastaldevelopmentcorp.com> Subject: RE: 5112: RE: Coastal Floor Turnover documents Diana, here are the remaining docs you should need. If I am missing anything please let me know. I included the checklist for file completeness even though I believe that ship has sailed. I will have the as-builts and disc with CAD/PDF send ASAP. Thanks for the patience and assistance on this one David C. Baggett, P.E. Project Engineer EfE§tS iQBURY'EYOR9 Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 ''2 772-462-2455, ext 113 A 772-408-4208 davidbaggett(c edc-inc.com From: Diana Spriggs [mailto:DSpriaas(a)cityofpsl.com] Sent: Tuesday, December 19, 2017 9:55 AM To: David Baggett Cc: Project File; Laney Southerly; nickCalcoastalfloorino.net; Sam Trotter; 'Gene' Subject: RE: 5112: RE: Coastal Floor Turnover documents The latest documents received are attached with our approval stamp on the lower right for your records. Please provide one hard copy signed and sealed of the as-builts along with the AutoCAD file. We also need the Wastewater Permit Certification form in order to put the gravity mains into service. Thank you, Diana Spriggs, P.E. Project Manager City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772)807-4452 From: David Baggett )mailto:davidbaggett@edc-inc.com] Sent: Monday, December 18, 2017 11:23 AM To: Diana Spriggs <DSpriggs@cityofpsl.com> Cc: Project File <ProiectFile@cityofpsl.com>; Laney Southerly <LSoutherly@citvofpsl.com>; nick@coastaiflooring.net; Sam Trotter <samtrotter@edc-inc.com>;'Gene' <Gene@coastaIdevelopmentcorp.com> Subject: RE: 5112: RE: Coastal Floor Turnover documents Good Morning Diana, please see attached the revised as -built survey and bill of sale. Per your request, the "Exhibit A" description for the bill of sale now matches the description on the easement documents (and owners affidavit). Sodding was completed this morning. I requested a final inspection on Friday before I left so as soon as staff can accommodate we will have that taken care of. J t 4 The FDEP cert is being mailed to your office though our turnover is not dependent on that. Please let me know if you require anything else at this time. When the as -built is approved I will have our survey division run off hardcopies for you, signed and sealed. Have a good day David C. Baggett, P.E. Project Engineer CN6Utt033 � EAINVLTOi1S Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 M 772-462-2455, ext 113 8 772-408-4208 �G davidbaooett(u)edc-inc.com From: Diana Spriggs rmailto:DSpriggs@citvofosl.coml Sent: Friday, December 15, 2017 5:21 PM To: David Baggett Cc: Project File; Laney Southerly; nicKDcoastalflooring.net; Sam Trotter Subject: RE: 5112: RE: Coastal Floor Turnover documents With so many copies going around; I was trying to just respond to the latest version. Once the legal description page of the Bill of Sale is revised, please resend so we can mark it as complete. Yes, please schedule your final inspection as soon as you are ready. The final inspection will not fail if the only thing missing is sod over the gravity since it is in an area that Will get over grown with weeds sooner than we would like. 1` Thank you, Diana Spriggs, P.E. Project Manager City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772)807-4452 From: David Baggett (mailto:davidbaggett@edc-inc.com] Sent: Friday, December 15, 2017 5:12 PM To: Diana Spriggs <DSpriggs@cityofpsl.com> Cc: Project File <ProiectFile@citvofpsl.com>; Laney Southerly <LSoutherly@citvofpsl.com>; nick@coastalflooring.net: Sam Trotter <samtrotter@edc-inccom> Subject: RE: 5112: RE: Coastal Floor Turnover documents Thanks Diana, i will have the owner look at the legal description on the Bill of Sale. I sent over a version with the correct asset list on Weds (attached) but maybe we got mixed up. Either way we will have the whole thing corrected and resent on Monday. I will have our survey correct those typo's and we will resend. I will request final inspection if we're clear to do that. Hardcopy of the FDEP cert will be mailed your way. Thankyou David C. Baggett, P.E. Project Engineer encar�t� raueivcroaa Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 19 772-462-2455, ext 113 8 772-408-4208 davidbaggett@edc-inc.com From: Diana Spriggs [mailto:DSpriggs@cityofpsl.com] Sent: Friday, December 15, 2017 5:04 PM To: David Baggett Cc: Project File; Laney Southerly; nick@coastalflooring.net Subject: 5112: RE: Coastal Floor Turnover documents Attached are the markups on the submitted documents. The documents with no further comments have our approval stamp on the lower right hand corner for your records. Please submit the original of the FDEP Clearance document so that we can have it signed by Mr. Merejo for your submittal to FDEP. Also, attached is the screen showing the Turnover documents that are still needed. The only remaining test to pass in the field would be the final inspection. If you have any questions, please let us know. Thank you, Diana Spriggs, P.E. Project Manager City of Port St. Lucie, Utility Systems Dept. 121 S.W. Port St. Lucie Blvd, Building B Port St. Lucie, FL 34984 (772)807-4452 From: David Baggett imailto:davidbaggett@edc-inc.com] Sent: Wednesday, December 13, 2017 4:48 PM To: Diana Spriggs <DSpriggs@cityofpsl.com> Subject: RE: Coastal Floor Diana, per our conversation please see attached the updated survey. All the other remaining/revised items are attached as well. If I need to forward these to the project file email address let me know. i Thankyou David C. Baggett, P.E. Project Engineer E31N eN6WEEA5 zauarcraa Engineering Design & Construction, Inc. (EDC), 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 n 772-462-2455, ext 113 A 772-408-4208 ,,�R davidbaggett(Wedc-inc.com From: Diana Spriggs fmailto:DSprioas cityofosl.com] Ju U L Sent: Wednesday, December 13, 2017 1:01 PM To: David Baggett 02 0 ,2 Subject: RE: Coastal Floor We are moving my office today so I am without a phone until this afternoon some time. I will call you as soon as I can From: David Baggett[maiIto: davidbaggett@edc-inc.com] Sent: Wednesday, December 13, 2017 11:00 AM To: Diana Spriggs <DSpriggs@cityofpsl.com> Subject: Coastal Floor Good Morning Diana, I just left you a voicemail regarding Coastal Floor. I am getting ready to send you a package of the remaining items you requested. I did not want to piecemeal it. Wire trace & marker inspection passed this morning— I will include that report as well. There is one thing I wanted to go over with you beforehand so if you could call me it would be greatly appreciated. It will only take a moment. Thankyou David C. Baggett, P.E. Project Engineer 'E 3[Kq [NGU+EEAE y! 7WNYEVdiS Engineering Design & Construction, Inc, (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 n 772-462-2455, ext 113 A 772-408-4208 e49 davidbag_aettCaledc-inc.com SCANRcL Joe Cicio BY „ From: Joe Cicio Sent: Tuesday, May 31, 2016 11:37 AM To: 'gene' Cc: 'nick@coastalfloorsplus.com'; Joe Cicio Subject: Emailing - Report_FL_Review_Comments_Noncompliantjrf.pdf Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf 1/i , C.J.,G N�'V Dear St. Lucie County/Permit Applicant,w�Lv `,r_V Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, lfoaeAd X &;c & Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner Sf Lwci,, Cov wly Pla.w.',.i" a*t& Deve tor+ z tf Se rvi cev Hofer way your szrv" today ** Plza+e- covultue+Carl. Pe-ferww, Ciui,(.aUi" O fLoi&L a+ der ov�j@vtLucieco org to-PXLI"� your s+�ggevfio�y, co mvte'4„tyavtd feed4ya� Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Gam` pia Joe Cicio From: Joe Cicio Sent: Wednesday, December 16, 2015 8:09 AM To: 'gene@coastaldevelopmentcorp.com' Cc: 'Tina@coastaldevelopmentcorp.com'; Joe Cicio Subject: Review Comments for Permit Number 1511-0282 Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf SC IVIVED Dear St. Lucie County Permit Applicant, St bide- ,�� Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank You, Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner SJ- Luc i. C,&� PL&v"-_L tg a*L& Pvvedopxvt,evv(-ServUzk Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Ij A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 (772)924-3575 OFFICE - (772)924-3580 FAx December 1, 2010 Palm Center, LLC Attention: Nick Elliot 2525 SE Federal Highway Stuart, Florida 34994 SCANNED BY St. Lucie Countv Re: Geotechnical Services for Stormwater Management Planning Proposed Coastal Floors Facility, 9600 South U.S. Highway No. 1 Port St. Lucie, St. Lucie County, Florida Project No. 10-1329 Ladies and Gentlemen: A. M. Engineering and Testing, Inc. is pleased to submit this geotechnical report for the referenced project. This report describes the project, field explorations, results of testing, findings, and recominendations. The project site is an approximately 1.253 acre parcel located in Section 26, Township 36S, Range 40E. The site is on the east side of U.S. Highway No. 1 approximately 1 mile south of East Prima Vista Boulevard, Port St. Lucie, St. Lucie County, Florida. The project comprises the construction of a one-story retail building with the associated access drives and parking areas. FIELD EXPLORATIONS The subsurface conditions at the project site were explored on November 22, 2010, with one Auger boring; Hand Cone Penetrometer (HCP) readings were taken at one -foot intervals in the auger boring. Subsequently an Exfiltration (EX) test was conducted in the borehole. The auger boring was performed in general accordance with ASTM D 1452, "Practice for Soil Investigation and Sampling by Auger Borings", and the exfiltration test with the SFWMD Usual Open Hole Test procedure. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. As requested by Friscia Engineering, the boring and exfiltration test were completed at the approximate location noted on the Boring Location Plan. The Exfiltration Test Report with the log from the auger boring is attached. The depths on the boring log are below the existing ground surface at the time the boring was performed. A. M. ENGINEERING AND TESTING, INC. Geotechnical Exploration for Stormwater Management Planning 9600 South U.S. Highway No. 1, Port St. Lucie, Florida Project No. 10-1329 FINDINGS The terrain at the project site was uneven. The grade of the site was about ''/z feet below US on the west side, and then sloped downwards to the east until about 4 feet below US1 at the furthermost east portion of the site. Also, the grade of the site was about''/2 feet below US 1 on the north side, and then sloped downwards to the south until about 4 feet below US1 at the furthermost southeast portion of the site. The auger boring/exfiltration test was performed at a location that was approximately 1 foot below US 1. Vegetation included pine and oak trees. The subsurface soils observed in the borings generally consisted of fine sand to fine sand with little silt from the ground surface to a depth of 5 feet, weakly cemented organically stained sand with little to some silt from 5 to 5;% feet, and then fine sand with some silt from 53/4 to a depth of 6 feet, the bottom of the boring. Ground water was encountered 6%: feet below the existing ground surface at the boring location. The water level was allowed to stabilize about one hour before measurements. USGS TOPOGRAPHICAL AND USDA SOIL SURVEY INFORMATION We reviewed the USGS 7.5-minute series quadrangle topographic map of the area, entitled Ankona. Revisions to this map were based on aerial photographs taken in 1983. The USGS map showed the project site is located on a broad area with an elevation of approximately 15 feet NGVD. Ponds are shown in the surrounding areas. The North Fork St. Lucie River runs approximately 2,500 feet west of the site. Extensive canal systems are shown west of The North Fork St. Lucie River. The site is shown on sheet number 33 of the Soil Survey of the St. Lucie County Area, Florida, issued by the U.S. Dept. of Agriculture in March 1980. According to the Soil Survey one soil type occurs within the project site, Waveland fine sand (50j. The Soil Survey describes Waveland fine sand as poorly drained, nearly level soil on broad flatwoods areas. The soil profile consists of fine sand to fine sand with little silt from the ground surface to a depth of 23/4 feet, fine sand with little to some silt to a depth of 5'/x feet and fine sand with little silt to a depth of 63/4 feet. With unimproved drainage, the water table is within a depth of 10 inches for 1 to 4 months and within a depth of 40 inches for 6 months or more during most years. It is perched above the subsoil early in the summer rainy season and after periods of heavy rainfall in other seasons. The water table recedes to a depth of more than 40 inches during extended dry seasons. Permeability is rapid in the surface and subsurface layers, very slow to slow in the subsoil, and moderate to rapid in the substratum. The high water table is perched and is at the ground surface to 1 foot below the ground surface. `A A. M. ENGINEERING AND TESTING, INC. Geotechnical Exploration for Stormwater Management Planning 9600 South U.S. Highway No. 1, Port St. Lucie, Florida Project No. 10-1329 It should be noted that the Soil Survey generally extends to a maximum depth of 80 inches (approximately 6% feet) below ground surface and is not indicative of deeper soil conditions. SOUTH FLORIDA WATER MANAGEMENT DISTRICT RAINFALL INFORMATION According to the SFWMD web site the rainfall in Martin and St. Lucie Counties during the 30 days prior to November 22, 2010, was 38 percent of the normal. During the 30 days prior to October 22, 2010 the rainfall was 52 percent of normal and during the 30 days prior to September 22, 2010 it was 60 percent of normal. The 2010 rainfall up to November 22, 2010 was 83 percent of normal. The 2009 rainfall was 79 percent of normal. DISCUSSION AND CONCLUSIONS The subsurface soils encountered in the auger boring correspond somewhat with the information presented in the Soil Survey. The Soil Survey does not mention the weakly cemented organically stained sand layer. The SFWMD data indicate the current water levels are below normal. Based on the above data and the results of our field exploration, we estimate that the average wet season high water table level is 3 feet below the ground surface at the boring/exfiltration test location. The auger boring/exfiltration test was performed at a location that was approximately 1 foot below the top of US1. However, should rainfall intensity and duration or total rainfall quantities exceed the normally anticipated rainfall quantities, the groundwater level may exceed our estimate of the average wet season high groundwater level. It should be noted for drainage system design that the soil layer described as weakly cemented sand with little to some silt has low permeability. The Soil Survey gives the coefficient of permeability for this material as less than 0.4 feet per day (1.4 x 104 cm/sec). Based on our experience the coefficient of permeability ranges from 0.01 to 0.1 feet per day (10A to 10-5 cm/sec). "Perching" of the ground water can be expected. LIMITATIONS This report is for the exclusive use of our client in the design and construction of the previously described project. The right to rely on this report may not be assigned without written permission of A. M. Engineering and Testing, Inc. This report has been prepared in accordance with generally accepted geotechnical engineering practices in the State of Florida. No other warranty, expressed or implied, is made. Our recommendations are based on the project information furnished to us, the results of our field explorations and our past experience. They do not reflect variations in subsurface conditions that may exist in unexplored areas of the site. The nature and extent of such variations may not become evident until further explorations are made or construction is underway. Should such 3 A. M. ENGINEERING AND TESTING, INC. Geotechnical Exploration for Stormwater Management Planning 9600 South U.S. Highway No. 1, Port St. Lucie, Florida Project No. 10-1329 variations be observed, we recommend that A. M. Engineering and Testing, Inc. be requested to observe the actual site conditions and re-evaluate our recommendations, if necessary. Environmental concerns, including (but not limited to) the possibility that hazardous materials or petroleum contaminated soils or groundwater may be present on the project site, were not included in the scope of work. Furthermore, our explorations did not include determination or delineation of "wetland" areas. GPS readings at a specific location are subject to some variability due to the satellite coverage and local conditions. An accuracy of approximately 20 feet is commonplace. A. M. Engineering and Testing, Inc. has appreciated the opportunity to assist you with this phase of your project. If you have any questions regarding this report or need any further information, please call us. Respectfully submitted, A. M. ENGINEERING AND TESTING, INC. �,;� onald W: Moler, P.E.- Senior Geotechmcal Engineer Florida Registration No. 60675 Attachments: Boring Location Plan Exfiltration Test Report (1) Key to Soil Classification Copies: Client (2) Friscia Engineering (1) ocio erlihan Staff Engineer ILServer-amelComparrylCO.D. JobslPalm Park Center, LLCICoastal Floors Facility, PSLIIO-1329 - Stormwater Report.doc N Ehrcd*1FAdam L. Hart, PE 1952 NW 21 ,t Terrace Stuart, FL 34994 772-215-8521 HRCD-COASTAL-06132016 SCANNED BY St. Luce County June 13th, 2016 Re: Coastal Floors New Building Permit To whom it may concern, Please refer to the attached submittal comments to the Drawing Review Comments Issued on the project above. Comment #1: 12/10/2015 Comment: PLS SUBMIT THE [ ORIGINAL j MANUFACTURERS ENGINEERED LAYOUTS AND CUT SHEETS FOR THE STEEL BAR JOIST SYSTEM AND BRIDGING REVIEWED AND APPROVED BY D.P. OF RECORD * NEED IN TRIPLICATE FOR REVIEW SUBMIT SAME AS ABOVE FOR THE VULCRAFT STEEL ROOF DECKING SYSTEM ENGINEER RESPONSE: Provided by Contractor/Owner Comment #2: 12/10/2015 Comment: PLS SUBMIT THE [ ORIGINAL j MANUFACTURERS ENGINEERED LAYOUTS W/ CUT SHEETS FOR THE METAL ROOF TRUSSES REVIEWED AND APPROVED BY D.P. OF RECORD * NEED IN TRIPLICATE FOR REVIEW * ENGINEER RESPONSE: Provided by Contractor/Owner Comment #3: 12/10/2015 Comment: SUBMIT THE MANUFACTURERS ENGINEERED LAYOUTS AND DETAILS FOR THE LIGHT GAUGE METAL FRAMING SYSTEM INCLUSIVE OF ALL DETAILS, PLATES, FASTENERS AND ACCESSORIES REVIEWED AND APPROVED BY D.P. OF / RECORD * NEED IN TRIPLICATE ENGINEER RESPONSE: Please refer to the attached metal framing documentation & new details on Revised Sheet 19 & revised Framing Note 14 on Sheet 16. All light gauge metal I , framing is non-structural and shall be installed per the manufacturers recommendations. Since the Florida Building Codes do not yet align with the International Building Codes, Note 14 on Sheet 16 has been updated to reference the Interr:s'entialprojects. to l Building Codes Section R603 for II non -load bearing applications on commercial and /J,J Comment #4: / IJA 12/15/2015 Comment: SUBMIT THE TESTED DETAILS ON PLANS FOR THE WP 1551 FILE CANNOT LOCATE THIS SYSTEM FOR THE 2 HOUR FIRE / SOUND WALL *** FLAG ON 3B STATES SEE 1-13 FOR THE 2 HOUR WALL DETAILS ** THERE ARE NO DETAILS ON SHEET 13 * PLEASE STATE THE CORRECT SHEETS FOR DETAILS ENGINEER RESPONSE: Please refer to the correct typos on sheet 3B — Sheet 19 contains the requested sections. HRCD-COASTAIl06132016 Comment #5: 12/15/2016 Comment: SHOW ALL REQUIRED WINDOW AND DOOR FLASHING DETAILS ON PLANS PER FBC 1405.4 AT ALL AREAS AS PRESCRIBED IN THIS SECTION THAT APPLY ENGINEER RESPONSE: Please refer to revised sheet 7 Window & Door buck details with flashing called out per FBC 1405.4, and added new details. Comment #6: 12/15/2015 Comment: CALCULATE THE INCREASED LOADS ON PLANS COMPLIANT WITH FBC 1607.4 FOR FORKLIFTS AND MOVABLE EQUIPMENT WHEEL LOADS AND AS STATED IN 1607.7.4.1 FOR IMPACT AND FATIGUE ON THE FLOOR AND SUPPORTING STRUCTURE * SHOW ON PLANS FOR THE STORAGE AND FACTORY AREAS ENGINEER RESPONSE: The design loads per information gathered from the client are as follows for the warehouse areas: Forklift Gross Weight:4800 Ibs (Existing Equipment) Gross Weight of Forklift Load: 1000 Ibs maximum Total Maximum Weight: 5800 Ibs < 10,000 Ibs Design Loads in these areas are less than 10,000Ibs maximum. Per FBC 1607.7, it is not required to comply with 1607.7.1-1607.7.5. Refer to added Note 11 on sheet 2. Plaques will be placed in the warehouse with signage that states: "Maximum gross weight of any vehicle with load shall not exceed 10,000 Ibs (4536 kg)" 1607.7 Heavy vehicle loads. Floors and other surfaces that are intended to support vehicle loads greater than a 10.000 pound (4536 kg) gross vehicle weight rating shall comply with Sections 1607.7.1 through 1607.7.5. 1607.7.1 Loads. Where any structure does not restrict access for vehicles that exceed a 10,000-pound (4536 kg) gross vehicle weight rating, those portions of the structure subject to such loads shall be designed using the vehicular live loads, including consideration of impact and fatigue, in accordance with the codes and specifications required by the jurisdiction having authority for the design and construction of the roadways and bridges in the same location of the structure. Comment #7: 12/15/2015 Comment: SHOW THE SIZE AND REQUIRED WALL LOCATION FOR THE REQUIRED MALTESE CROSS ON PLANS * SEE FAC 69A-60 ENGINEER RESPONSE: Refer to revised Sheet 4. Maltese will be installed within 24" to the left of the entry door, and at 60" AFF per FAC 69A-60. Comment #8: SHOW THE DETAILS ON PLANS FOR THE EXTERIOR PLASTER APPLICATION PER FBC 2512 * SHOW ALL DETAILS AND TESTING REQUIREMENTS *** SHOW A WALL DETAIL FOR THE KNEE WALLS SUPPORTING THE WOOD TRUSSED ROOF * PLANS SHOW METAL STUDS WITH STUCCO OVER WIRE LATH * SHOW ALL WEATHER BARRIERS AND REQUIRED BACKING PER FBC 2510.5 AND 2510.5.1 ENGINEER RESPONSE: Refer to revised Sheets 9, 10, and 11. Comment #9: 12/1512015 Comment: WHAT TYPE OF SOFFIT AND VENTILATION WILL BE INSTALLED IN THE RAISED TILE ROOF AREA * SHOW DETAILS ON PLANS 14RCD-COASTAL-06132016 ENGINEER RESPONSE: Per the note on Sheets 9 & 10, All Soffits shall be wire lathe & stucco. The roof structure will be insulated with Icyene therefore no venting is required. Comment #10: ALL PLANS SUBMITTED MUST BE IN ORIGINAL SIGNED, SEALED AND DATED FORMAT WE DO NOT ACCEPT PLAN COPIES OR DIGITAL SEALS AT THIS TIME * SEE F.S. 471.025 AND FAC 61G15-23.002 ENGINEER RESPONSE: Please refer to the attached revised drawings signed in Blue Ink per your request to evidence an overlapping signature per F.A.C. All drawings and seals are in compliance with F.S. 471.025 & F.A.C. The drawings submitted contain what is classified as a "Wet' seal. As defined by FAC 61 G15-23.002 (1)(a), A Wet Seal is defined as any seal physically applied to a printed document capable of leaving a permanent ink representation or any other form of opaque permanent impression on the printed document that complies with subsection 61G15-23.002(2), F.A.C. Digital Seals are defined by F.A.C. 61G15-23.004, and are not the same as the "Wet" seal provided on these drawings. Comment #11: 5/31/2016 Comment: PLEASE CORRECT THE PHONE NUMBERS AND E-MAIL CRITERIA ON THE PERMIT APPLICATION AND CHANGE THE DESIGN PROFESSIONAL INFORMATION TO ADAM HART ENGINEER RESPONSE: Provided by the Contractor/Owner Comment #12: 5/31/2016 Comment: SOME LINTELS ARE IDENTIFIED INCORRECTLY ON THE LINTEL PLAN CORRESPONDING TO THE LINTELCHART AND SOME OPENINGS ARE NOT SPECIFIED PLEASE CORRECT ENGINEER RESPONSE: Referto revised Sheet 5. A note was provided defining lentils that are not labeled on the drawing, but additional clarification has been added for guidance on engineering design intent. Comment #13: 5/31/2016 Comment: WIND CHART ON SHEET 4 PERTAINS TO A SINGLE FAMILY DWELLING IN THE RESIDENTIAL CODE AND DOES NOT APPLY TO THIS PROJECT PLEASE CORRECT ENGINEER RESPONSE: Referto revised Sheet 4. All designed performed to ASCE 7-10 & 2014 FBC. Comment #14: 5/31/2016 Comment: MASONRY NOTES ON SHEET 16 REFERS TO THE 2010 EDITION OF THE CODE *WE ARE CURRENTLY ENFORCING THE 2014 CODES ENGINEER RESPONSE: Referto revised Sheet 16—typos have been corrected. Comment #15: 5/31/2016 Comment: MISC NOTES ON SHEET 16 REFERS TO THE 2007 EDITION OF THE CODE * WE ARE CURRENTLY ENFORCING THE 2014 CODES HRCD-COASTAL-06132016 ENGINEER RESPONSE: Refertb revised Sheet 16 —typos have been corrected Comment #16: 5/31/2016 Comment: DESIGN PROFESSIONAL TO IDENTIFY THE RISK CATEGORY ON PLANS FOR THIS BUILDING PER FBC 1604.5 ENGINEER RESPONSE: Referto Sheet 4 — Risk Category defined as II in Wind Load Chart. Comment #17: 5/31/2016 Comment: SHOW THE REQUIRED IMPACT LOAD BUILDING PROTECTION ON PLANS PER FBC 1607.9 ENGINEER RESPONSE: Referto Sheet 4 & Response to Comment #6 above Comment #18: 5/31/2016 Comment: PRODUCT APPROVAL TABLE SHEET 1 *** IF STATING PER N.O.A. INSTALLATION SUBMIT LEGIBLE N.O.A'S [TRIPLICATE ] WITH THE FASTENER TABLES HIGHLIGHTED AND COVER PAGE TO BE APPROVED BY THE DESIGN PROFESSIONAL OF RECORD ENGINEER RESPONSE: Provided by Contractor. Comment #19: 5/31/2016 Comment: EXTERIOR SWING DOOR INSTALLATION PRODUCT APPROVAL SHEETS MUST BE SUBMITTED IN TRIPLICATE, REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD ENGINEER RESPONSE: Provided by Contractor. Comment #20: 5/31/2016 Comment: PLANS SPECIFY FL# 742.9 FOR THE OVERHEAD DOORS / PRODUCT APPROVALS SUBMITTED ARE FOR A DIFFERENT DOOR AND ARE INCOMPLETE ENGINEER RESPONSE: Provided by Contractor. Comment #21: 5/31/2016 Comment: VARIOUS PLAN SHEETS ARE SPECIFYING A FOAM ROOFING SYSTEM WITH GRAVEL AND THE PRODUCT APPROVAL TABLE [ N.O.A. # 14-0617.05 ] IS FOR A SINGLE PLY PVC SYSTEM /// PLS CORRECT ONE OR THE OTHER AND SUBMIT THE PROPER SYSTEM NUMBER FROM THE N.O.A PROPOSED * BE SURE THAT THE METAL ROOF DECKING IS BEING ATTACHED TO THE BAR JOISTS PER THE N.O.A. CRITERIA ENGINEER RESPONSE: Refer to revised Sheets 7-12 for requested change to roofing system call out. Comment #22: 5/31/2016 Comment: FOUNDATION NOTES ON SHEET 16 ARE SPECIFYING A 4" SLAB AND OTHER PLAN PAGES ARE SPECIFYING 6" AND 4" ** DESIGN PROFESSIONAL TO ADD THE 6" CRITERIA IN THE NOTES ENGINEER RESPONSE: Refer to revised Sheet 16 Notes. Note revised to say 4"— 6" since both thickness are being called out on the drawings. Comment #23: El HRCD-COASTAG06132016 5/31/2016 Comment: ARE YOU PROPOSING FL 7804 # 1 OR 2 FOR THE ENTEGRA ROOF TILE INSTALLATION * PLEASE SPECIFY A SYSTEM NUMBER THE PROPOSED INSTALLATION * FOAM OR MECHANICALLY ATTACH * NEED THE UNDERLAYMENT INSTALLATION TO MEET OR EXCEED THE REQUIRED DESIGN PRESSURES IF FOAMING THE TILE * NEED ALL DOCUMENTS IN TRIPLICATE ENGINEER RESPONSE: Provided by Contractor. FL7804.1 is being submitted as the proposed roofing system, mechanically fastened. Comment #24: 5/31/2016 Comment: CONTRACTOR TO RE -SUBMIT ALL DOCUMENTS IN TRIPLICATE WITH THE REQUIRED ORIGINAL, SIGNED, SEALED AND DATED PLANS W/ [2 ] PDF DISCS ENGINEER RESPONSE: Referto attached requested documents. Comment #25: 5/31/2016 Comment: SHEET 3B SPECIFYS 40 AND A 30 1.5 HOUR RATED DOORS IN THE 2 HOUR WALL H DOOR AND WINDOW SCHEDULE ON SHEET 1 SPECS 20 MIN. ** THERE ARE [ 21 DIFFERENT FIRE WALL DETAILS ON SHEET 19??? * PLANS SHOW 1 [ 2 ] HOUR WALL ENGINEER RESPONSE: Referto REVISED SHEET 1 AND 3B. Doors in schedule updated to be 90 minute doors per code. If you have any questions, feel free to contact me at your earliest convenience. Respectfully Submitted By, 6/13/2016 Adam L. Hart, P.E. License # 63079 1952 NW 2151 Terrace, Stuart, FL 34994 772-215-8521 °Opp L. * : No 6633 HRCD-COASTAG06132016-PA Adam L. Hart, PE 1952 NW 21*Terrace yJJ Stuart,FL 34994 772-21515-8521 June 13th, 2016 Re: Coastal Floors New Building Permit To whom it may concern The attached product approvals have been reviewed and approved for use on this building Please refer to the following list below. Product Approval Records: Roofing Systems: Hip Roof: Entegra Concrete Roof Tile, Mechanically fastened per FL 7804.1 Flat Roof: Duro-last Single Ply Roofing System installed per NOA 14-0617.05 Window Systems: PGT Industries Fixed Glass SS-3500 Aluminum Store Front System installed per NOA 15- 0612.08 Exterior Store Front Door Systems: PGT Industries Fixed Glass SS-3550 Aluminum Store Front System installed per NOA 15- 0612.09 Exterior Door Systems: Ingersoll Rand SZ-Series Commercial Hollow Metal Door installed per FL13884.1 Garage Door Systems: Overhead Door Model 610/611 installed per FL742.9. If you have any questions, feel free to contact me at your earliest convenience Respectfully Submitted By, 6/13/2016 Adam L. Hart, P.E. License # 63079 1952 NW 21" Terrace, Stuart, FL 34994 772-215-8521 ,,pM'� rH,q����i, * No 63079 ir ST TE F December 21, 2017 ST. LUCIE COUNTY BOARD OF COUNTY Via; Email and mail SCANNED COMMISSIONERS David C. Baggett, P.E. BY St. Engineering Design and Construction Inc. Lucie Count, CHRIS DZADOVSKY 10250 SW Village Parkway, Suite 201 CHAIRMAN Port St Lucie, FL349S7 DISTRICT 1 Reference: Coastal Floor and Granite-US1 TOD MOWERY St. Lucie County Stormwater Permit VICE-CHAIRMAN As -Built and Engineer's Certification DISTRICT 2. Dear Mr. Baggett, LINDA BARTZ DISTRICT 3 St. Lucie County has received thews -built plans dated December 15, 2017 and the engineer's letter of certification forthe above named project. Based an staff review of the FRANNIE HUTCHINSON as -built plans and a site inspection, it has been determined that additional effort is DISTRICT 4 necessary, in order to comply with St. Lucie County standards. Please refer to the comments below and provide the requested supplemental information to complete the project. Per the Land Development Code Chapter 11.03, please submit two (2) copies of CATHY TOWNSEND signed and sealed as -built, two (2) copies of signed and sealed. engineer's certifications, DISTRICT 5 and all geotechnical test results with your resubmittal. HOWARD N. TIPTON Certification Letter Comments: COUNTY ADMINISTRATOR 1. The Engineer's letter of certification must specifically identify substantial deviations from the approved plan. For example, SD#2 top elevation changed from 15.33to 16.54, DAN MCINTYRE MES invert elevation changed from12.53 to 11.49. These changes are beyond generally COUNTY ATTORNEY accepted tolerances. Please review the project in Its entirety and. state any such deviations on your resubmittal. MAILING ADDRESS 2300 VIRGINIA AVENUE Geotechnical Report Comments: FORT PIERCE, FL 34982 PHONE 1. 'No density test results or proctor tests were submitted with the certification package. (772) 462-251 t Please submit all available test results for stormwater pipe and stormwater structures in accordance with Florida Department of Transportation Standards. TDD (772) 462.1428 As -Built Plan Comments: FAX 1. The plans must depict critical pavement spot elevations, changes in grade or slope, the (772) 462-2363 top of bank along the periphery of project, roof drain -box elevations, toe of slope and sufficient elevations for all accessible routes to demonstrate compliance with all applicable E-MAIL thottakara- a-stlucieco.otg regulations. 2. Please label the Swale top of bank and the of slope or use different line types for each ± WESSITE feature. WWW,STLUCIECO.GOV e��e��@@ pN {pp{,mm�� 1 ` �+ ST. -iLUCE tl 10IT KSO December 21, 2017 Page 2 of 2 Field Review `Commehtsi- 1. Roof drains discharging along the southern portion of the project appear to convey runoff directly beyond theproperty. Demonstrate that all stormwater runoff is contained within the project boundary, in accordancewith-thepermitted activity. 2. All disturbed areas must be stabilized. Many areas of work remained in a bare condition as a result of contractor activity. 3. Ruts from activity:along the NE corner of the property shall be re -graded and,sodded. 4. A material stockpile, near the SE corner of the site existed during the final inspection. This material must be removed and the area regraded and 'sodded 'to design intent. All remaining construction debris must be: removed from the site. S. It appears that the concrete pad placed at the SW corner of the building is not reflected on the as -built plans. Demonstrate that the as -built plans and permitted plans reflect actual site conditions. Also demonstrate that this additionalimpervious area is included in site stormwater calculations. ,6. All silt fence shall be removed from the project. 7. A Notice of Termination (NOT) form 62-621.300(6) shall must be filed with FDEP„with a copy provided to this office. Advisory comments 1. Remove sedimentation from drainage structures and pipes. 2. It was noted that the truncated domes at the parking lot crosswalk were not installed as per plan. Please review.and.provide comment. All inconsistencies with St..Lucie County standards shall be corrected prior to final certification of the project by St. Lucie County. Our_findings are not to be considered all-inclusive and we encourageyou to make an independent review of the work in its entirety. We would appreciate your assistance in addressing these matters. Pleasemakean independent review and'advise us as to the corrective actions to betaken. If there are any questions please feel free to call meat (772) 462-2511 or email me atThottakarab@stlucieco.ore. Sincerely, Baby Thottakara, PE jo2�i// 0)/� Water Quality Division Civil Engineer Cc email only: Don west, PE— Public Works Director Kim.GrAmu, PE —County Engineer Patrick Dayan,PE— Worer Quality Manager (email) Rod Reed; PLS—County Surveyor Gdy Boisclair— Regulatory Professional, SFNMD Monica Graziant— Building and Code Manager 11Boccfs02�slwutS\CMPD%grottp\R&BNCOMMOMWater Quality\Development RevicMStormeater Permits Approvals)l I • Coastal floor.. and Granite 201112081Response to. cent -Coastal Floor and Granitc.doex STo LUCIE \IVOj KS Joe Cicio From: Sent: To: Subject: Attachments: See below and attached. Thank you David C. Baggett, P.E. Project Engineer • ENGWCCPS ZSURVETbGs David Baggett <davidbaggett@edc-inc.com> Friday, January 12, 2018 3:13 PM Joe Cicio FW: COASTAL FLOORING & GRANITE SLC Response to Coastal Floor Granite_20171221.pdf Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 S 772-462-2455, ext 113 A 772-408-4208 qsI3 davidbaggett0edc-inc.com From: Edmund Bas [mailto:base@stlucieco.org] Sent: Friday, December 29, 2017 11:52 AM To: David Baggett Cc: Kimberly Graham; Baby Thottakara; Joe Cicio Subject: COASTAL FLOORING & GRANITE David, SCAIVIVEL) St. LuBY Cie Counn` ,We have reviewed the certification package you provided and inspected the site for the above development. We share the same comments provided by the County's Water Quality Division dated December 22, 2017 as attached. Please address these comments and provide a copy of the revised package to the Engineering Division for review. Should you have any questions, please do not hesitate to ask. Thanks, Edmund S. Bas, P.E. Assistant County Engineer !•►BEST, plates DLiUCAUc"#mr St. Lucie County Engineering Division 2300 Virginia Ave., Rm. 229 Fort Pierce, FL 34982 Direct: (772) 462-2184 • Main: (772) 462-1rui + Fax: (772) 462-2362 Email: basec@stiucieco.org • Website: www.stiucieco.org Please Note: Florida has very broad public records laws. Mostwritten communications to or from County officials regarding County business are public records -available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Joe Cicio From: David Baggett <davidbaggett@edc-inc.com> Sent: Friday, January 12, 2018 2:36 PM To: Joe Cicio Cc: nick@coastalflooring.net;'Gene' Subject: FW: Coastal Floor and Granite-US1 Attachments: Coastal Floor and Granite Acceptance SLC WQD_20180112.pdf Joe, please see attached acceptance letter from WQD. Please let us know if you need anything else. Thank you David C. Baggett, P.E. Project Engineer r EammC SLnh'EYat Engineering Design & Construction, Inc. (EDC) 10250 SW Village Parkway, Suite 201 Port St. Lucie, FL 34987 M 772-462-2455, ext 113 A 772-408-4208 � davidbaggettcbedc-inc.com From: Baby Thottakara [mailto:Thottakarab@stlucieco.org] Sent: Friday, January 12, 2018 2:22 PM To: David Baggett; Lydia Galbraith Cc: Don West; Kimberly Graham; 'Boisclair, Guy'; Patrick Dayah; Rod Reed Subject: Coastal Floor and Granite-US1 David, Lydia Please see the attached. Thanks Baby Thottakara, P.E. Civil Engineer 2010 & 2047 "towtit St. Lucie County Water Quality Division 3071 Oleander Avenue Fort Pierce, FL 34982 Direct: (772) 462-2097 • Main: (772) 462-2511 • Fax: (772) 462-2363 Email: thottakarab(lstlucieco.ora • Website: www.stlucieco.ora SCANNED BY St. Lucie Count, Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Sr. LUCIE COUI\TI'Y BOARD OF COUNTY COMMISSIONERS FRANNIE HUTCHINSON CHAIR DISTRICT 4 F LINDA BARTZ VICE -CHAIR DISTRICT 3 CHRIS DZADOVSKY DISTRICT 1 CATHY TOWNSEND DISTRICT 5' HOWARD N. TIPTON COUNTY ADMINISTRATOR DAN MCINTYRE COUNTY ATTORNEY MAILING ADDRESS 2300 VIRGINIA AVENUE t,FORT PIERCE, FL 34982 PHONE (772) 462-251 1 TDD (772) 462-1428 FAX (772) 462-2363 E-MAIL THOTTAKARAB@STCUCIECO.ORG WEBSITE W W W.STLUCI ECO.GO V STATER QUALITY DIVISION January 12, 2018 Via: Email and mail David C. Baggett, P.E. Engineering Design and Construction Inc. 10250 SW Village Parkway, Suite 201 Port St Lucie, FL 34987 Reference: Coastal Floor and Granite-US1 St. Lucie County Stormwater Permit As -Built and Engineer's Certification Dear Mr. Baggett, BY - St Cucie County JAN 12 RECD 1,5/ St. Lucie County has received the resubmission of as-built,plans dated J.muaq- 11, 2018 aurd the cngineer's leper of cerdlication for'the above maned project. 1iaserl oil stair review or tile as -built plans, as built drainage calculations vita site inspection, it has been determined that the proiccl is in substantial compliance with St. Lucie County standards with relercncc to Stornuvater Mvngernent. Your submission of responses to Ilse comments, Field corrections and density test results are acceptable. St. Lucie County's Water QuAly Division lids no additional comments and X'0 objection to the issuance of Ilse Certificate or OCCupaucy. If tlicr e are any questions please Feel free to Call tnc at (772) 462-2097 or email nu at 77tcxtalc,imb@slluciceo.oi-L. laSi rely, ��/���i�i`.�- / y T takara, PE Water Quality Division — Civil Engineer Cc email only: Dan West,P.E.-Director, Public\Yorks Kimberly Graham, P.E—County Engineer Patrick.Dayan, P.E. — Water Quality Division Manager Rod Reed, PlS—County Surveyor Selena Grilrett, P.E.—Civil Engineer Guy Boisclair—SFWMD \\Boccr502\slcour$\CMPD\gmtip\R&B\COMMON\1Vater.QualityADevelopntenl RevieMStomniater Permits Approvals\I (- Coastal Floor and Gunite_20111208\Coastal Floor and Granite: Acceptance SLC WQD_20180112,doCK ST. LUCIE ` 11,10I= ifS, January 12, 2018 ST. LUCIE COUNTY Via: Email and mail BOARD OF COUNTY COIVMSSIOI\TERS David C.Baggett, P.E. Engineering Design and Construction Inc. FRANNIE HUTCHINSON 10250 SW Village Parkway, Suite 201 CHAIR Port St Lucie, FL34987 DISTRICT 4 Reference: Coastal Floor and Granite-US1 p' LINDA BARTZ. St. Lucie County Storm Water Permit DISTRICT DISTRICT 3 3 As -Built and Engineer's Certification Dear Mr. Baggett, CHRIS DZADOVSKY DISTRICT 1 St. Lucie County has received theresubmission of as -built Plans dated January 11, 2018 and the engineer's letter of certification for the above named project. 'I3ased onstalf reviewof the as -built plans, as built (Imillage calndations and a site inspection, it has been determined that CATHYTOWNSEND (he project is in substantial compliance \rith St. Lucie County standards vith reference to DISTRICT B- S(GI'llwralel' iN'Ia11age1nC11(. YOIn' Sllbinlssl011 Of 1'CSpOnSCs (O II1C COI17I11CIlls, field t'Orl'eCt10i15 and density test results are accepulble. HOWARD N. TIPTON COUNTY ADMINISTRATOR `^ $t. LLICIC CGwnty's Water' llfihtl' 1)1\751011 haS no a(1(IltlOnal ('011llllellts and NO Ol)ICCtloll to the issuance Of [lie Certificate Of Occupancy. If bhcre are any questions Please feel flee to call nlc at (772) 4(i22097 or email nie ;It'1'llotlakarabns(IuciecO.OI DAN MCINTYRE COUNTY ATTORNEY t $I rely, ('�`�, 1 lay MAILING ADDRESS T takara, PE P2300 VIRGINIA AVENUE Water Quality Division —Civil Engineer FORT PIERCE, FL 34982 Cc entail only: PHONE (772) 462-251 1 Dun %Vest,.P.E.=Director, Public Works Kimberly Graham,RE— County Engineer Panick.Dayan, P.E. — Water Quality Division Manager Rod Reed, PLS— Cdunty Surveyor Selena Gritfeu;.P.E,—Civil Engineer TDD Guy Boisclait—SFWtviD (772) 462-1428' FAX (772) 462-2363 E-MAIL THOTTAKARAB@STLUCIECO.ORG VVEBSITE \\Boecfs02vslcout$kCMPD\gronp112&B\COMMON\\Voter Quality1Development Revieic\Stomlualer Peradis Approvals\t t- WWW.STLUCIECO.GOV Coastal Floor and Granite20111208\Costal Floor and Granite Acceptailce SLC WQD-20180t12.docs ST. LUCIE ` VOHK Lydia Galbraith From: Lydia Galbraith Sent: To: Thursday, March 29, 2012 4:29 PM Robin Meyer SCANNED Cc: Mark Satterlee; Paula Bushby; Michael Brillhart StBY . Lucie cie Count%, Subject: Impact fees, Coastal Floor and Granite Attachments: DOC1112-0186impactfees.pdf Tracking: Recipient Read Robin Meyer Read: 4/3/2012 8:09 AM Mark Satterlee Read: 3/29/2012 5:38 PM Paula Bushby Read: 3/30/2012 7:17 AM Michael Brillhart Read: 3/29/2012 4:35 PM Robin, The contractor is complaining about the Impact Fees. According to his opinion we should charge the Impact Fees based on two uses, storage and retail. He also feels that it is not clear what we have deducted from the impact fees for the buildings that previously were demolished. The Site Plan is our leading document. The Site plan is totally based on Carpet store/retail. The calculation of the parking was based on the total sf of building. We didn't make a difference between storage and retail. Also the Impact Fees were based on retail for the total sf. of building. The Property Appraisers office informed us that in 1991 the property had two buildings with a total of 2,544 sf. The original buildings were demolished and taken of the tax roll in 1992. For the calculation of the Road Impact fees we subtract 2,544 sf. The other Impact Fees were not in effect at the date of demolition so we were not able to subtract anything from the other Impact Fees. At 1/30/12 the contractor was informed about the calculation of the Impact fees. We let him know that if they had paperwork that showed a different sf. of buildings to bring it in so we could review it. The contractor didn't respond to that. See attached Impact Fee calculation sheet. The question is now, did we calculate the Impact Fees correct, or do we need to base it on retail and storage? Our Impact Fee schedule doesn't provide an Impact Fee for storage. We do have an Impact Fee for Warehousing but that is not a permitted use in Commercial General Zoning. Please advise. Thanks, L_ddta g catbratth Planning Technician Planning and Development Services Phone: (772) 462-1555 Fax: (772)462-6448