Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue FortPierce, FL. 34982 Phone:V72)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 8532 S US 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3414-501-1903-200/7 Zoning: CG APPLICATION INFORMATION Permit Number: 1511-0282 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Eugene F Santoro Business Name: Coastal Development Inc Business Addr: 8509 S Federal Hwy City / State / Zip: Port St Lucie, FI 34984 REVIEWS AND COMMENTS Review Type Status ADDRESSING ASSIGNMENT COMPLETE Comment: REVIEW COMMENTS SCANNEp St. cute count, 7 Owner(s): Palm Park Center Llc Jurisdiction: ST LUCIE COUNTY Lot#: 3 Block: 3 Stories: Automatic Sprinkler System? No Fax Number: Email: Reviewed By Date Started Date Completed Date Released Lydia Galbraith 1112312016 11/2312015 11/23/2015 DOCUMENTS MISSING PENDING Deanna Givens 12/1112015 Comment: SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICAL AND ROOF & SUB SUMMARY SHEET 2/1712016 Comment: VEG PERMIT IN DRAWER UNDER "C" COASTAL ENVIRONMENTAL REVIEW COMPLETE Ben Baicer 11/1812015 211812016 211812016 Comment: FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 1112312016 11/23/2015 11123/2016 Comment: PE REVIEW COMMENTS (2) INCOMPLETE Joe Cicio 6/31/2016 CommenYk PLS SUBMIT THE [ ORIGINAL I MANUFACTURERS ENGINEERED LAYOUTS AND CUT SHEETS FOR THE 12/10/2015 STEEL BAR JOIST SYSTEM AND BRIDGING REVIEWED AND APPROVED BY D.P. OF RECORD' NEED IN TRIPLICATE FOR REVIEW' SUBMIT SAME AS ABOVE FOR THE VULCRAFT STEEL ROOF DECKING SYSTEM "' DID NOT RECEIVE ANY INFORMATION FOR THIS `"' Comments PLS SUBMITTHE [ ORIGINAL ) MANUFACTURERS ENGINEERED LAYOUTS W/ ORIGINAL SIGNED, SEALED 12/10/2015 AND DATED CUT SHEETS FOR THE WOOD ROOF TRUSSES REVIEWED AND APPROVED BY D.P. OF RECORD' NEED IN TRIPLICATE FOR REVIEW •"" DID NOT RECEIVE •"" C Planning& Development Services 7 '`� REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34962 / Phone:(772)462.2172 Fax:(772)46?, "-3\ Co me t: T THE MANUFACTURERS ENGINEERED LAYOUTS AND WALL DETAILS FOR THE LIGHT GAUGE 12/10/2015 IfA`1 AL FRAMING SYSTEM OR DESIGN BY THIS DESIGN PROFESSIONAL INCLUSIVE OF ALL DETAILS, LATES, FASTENERS AND ACCESSORIES REVIEWED AND APPROVED BY D.P. OF RECORD' NEED IN TRIPLICATE •• DID NOT RECEIVE Cot9m/ SUBMIT AN ORIGINAL SIGNED,SEALED AND DATED SOIL TEST FOR REVIEW' SEE SHEET 16 12/10/2015 X / REQUIREMENTS' SOIL TESTING TO STATE THE LOAD BEARING VALUES DETERMINED BY THE TESTING vC FOR THE BUILDING STRUCTURE Comment: SUBMIT THE TESTED DETAILS ON PLANS FOR THE WP 1551 FILE' CANNOT LOCATE THIS SYSTEM FOR 12/1512015 THE 2 HOUR FIRE / SOUND WALL ••• FLAG ON 3B STATES SEE 1-13 FOR THE 2 HOUR WALL DETAILS •• THERE ARE NO DETAILS ON SHEET 13 • PLEASE STATE THE CORRECT SHEETS FOR DETAILS 12/15/2015 Comment: SHOW ALL REQUIRED WINDOW AND DOOR FLASHING DETAILS ON PLANS PER FBC 1405.4 AT ALL AREAS S PRESCRIBED IN THIS SECTION THAT APPLY CommeAct-COOR ALCULATE THE INCREASED LOADS ON PLANS COMPLIANT WITH FBC 1607.4 FOR FORKLIFTS AND 12/15/2016 AND SUPPORTING STRUCTURE' SHOW ON PLANS FOR THE STORAGE AND FACTORY AREAS 12/15/2015 Comment: SH THE SIZEAND REQUIRED WALL LOCATION FOR THE REQUIRED MALTESE CROSS ON PLANS' SEE F 69A-60 Comment: SHOW THE DETAILS ON PLANS FOR THE EXTERIOR PLASTER APPLICATION PER FBC 2512 • SHOW ALL 1211112015 D AILS AND TESTING REQUIREMENTS ••' SHOW A WALL DETAIL FOR THE KNEE WALLS SUPPORTING E WOOD TRUSSED ROOF 'PLANS SHOW METAL STUDS WITH STUCCO OVER WIRE LATH' SHOW ALL / ATHER BARRIERS AND REQUIRED BACKING PER FBC 2510.5 AND 2510.5.1 12/1512015 Comment: WHAT TYPE OF SOFFIT AND VENTILATION WILL BE INSTALLED IN THE RAISED TILE ROOF AREA' SHOW ETAILS ON PLANS 5/31/2016 Comment:/,K PLANS SUBMITTED MUST BE IN ORIGINAL SIGNED, SEALED AND DATED FORMAT' WE DO NOT .'/ CEPT PLAN COPIES OR DIGITAL SEALS AT THIS TIME' SEE F.S. 471.025 AND FAC 61G15-23.002 5/31/2016 Comment: EASE CORRECT THE PHONE NUMBERS AND E-MAIL CRITERIA ON THE PERMIT APPLICATION AND ANGE THE DESIGN PROFESSIONAL INFORMATION TO ADAM HART 5/31/2016 Comment: SO LINTELS ARE IDENTIFIED INCORRECTLY ON THE LINTEL PLAN CORRESPONDING TO THE LINTEL `/ C ART AND SOME OPENINGS ARE NOT SPECIFIED • PLEASE CORRECT 5131/2016 y{ Comment: KNRY ON SHEET 4 PERTAINS TO A SINGLE FAMILY DWELLING IN THE RESIDENTIAL CODE AND 1 D EPPLY TO THIS PROJECT' PLEASE CORRECT 5131/2016 Comment:. OTEB ON SHEET 16 REFERS TO THE 2010 EDITION OF THE CODE • WE ARE CURRENTLY ORCING THE 2014 CODES 5/31/2016 Comment: � MISC TES ON SHEET 16 REFERS TO THE 2007 EDITION OF THE CODE' WE ARE CURRENTLY f ENF CING THE 2014 CODES 6/3112016 Comment: SIGN PROFESSIONAL TO IDENTIFY THE RISK CATEGORY ON PLANS FOR THIS BUILDING PER FBC 604.5 5/31/2016 Comment: JmILICATE HOWTHE REQUIRED IMPACT LOAD BUILDING PROTECTION ON PLANS PER FBC 1607.9 Comment:R UCTAPPROVAL TABLE SHEET 1 ••• IF STATING PER N.O.A. INSTALLATION SUBMIT LEGIBLE N.O.A'S513112016 ]WITH THE FASTENER TABLES HIGHLIGHTED AND COVER PAGE TO BE APPROVED BY THE GN PROFESSIONAL OF RECORD 5/31/2016 Comment: TERIOR SWING DOOR INSTALLATION PRODUCT APPROVAL SHEETS MUST BE SUBMITTED IN (PLICATE ,REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD 5/31I2016 Comment: PLANS SPECIFY FL# 742.9 FOR THE OVERHEAD DOORS / PRODUCT APPROVALS SUBMITTED ARE FOR A DIFFERENT DOOR AND ARE INCOMPLETE Comment: VARIOUS PLAN SHEETS ARE SPECIFYING A FOAM ROOFING SYSTEM WITH GRAVEL AND THE PRODUCT 5/31I2016 APPROVAL TABLE [ N.O.A. # 14-0617.05 ] IS FOR A SINGLE PLY PVC SYSTEM /// PLS CORRECT ONE OR THE OTHER AND SUBMIT THE PROPER SYSTEM NUMBER FROM THE N.O.A PROPOSED' BE SURE THAT THE ETAL ROOF DECKING IS BEING ATTACHED TO THE BAR JOISTS PER THE N.O.A. CRITERIA 5/31/2016 Comment: FOUNDATION NOTES ON SHEET 16 ARE SPECIFYING A 4" SLAB AND OTHER PLAN PAGES ARE PECIFYING 6" AND 4" •• DESIGN PROFESSIONAL TO ADD THE 6" CRITERIA IN THE NOTES Comment: ARE YOU PROPOSING FL 7804 # 1 OR 2 FOR THE ENTEGRA ROOF TILE INSTALLATION • PLEASE SPECIFY 5/31/2016 A SYSTEM NUMBER THE PROPOSED INSTALLATION' FOAM OR MECHANICALLY ATTACH' NEED THE UNDERLAYMENT INSTALLATION TO MEET OR EXCEED THE REQUIRED DESIGN PRESSURES IF FOAMING THE TILE' NEED ALL DOCUMENTS IN TRIPLICATE 5/3l/2016 Comment: J CONTRACTOR TO RE -SUBMIT ALL DOCUMENTS IN TRIPLICATE WITH THE REQUIRED ORIGINAL, SIGNED, SEALED AND DATED PLANS W/ [ 2 ] PDF DISCS Comment: SHEET 3B SPECIFYS 40 AND A 30 1.5 HOUR RATED DOORS IN THE 2 HOUR WALL // DOOR AND WINDOW 5/31/2016 SCHEDULE ON SHEET 1 SPECS 20 MIN. "THERE ARE [ 2 ] DIFFERENT FIRE WALL DETAILS ON SHEET 19 ??? • PLANS SHOW 1 [ 2 1 HOUR WALL Planning & Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(7721462-6443 REVIEW COMMENTS 3 5/31/2016 Comment: COMMENTS E-MAILED AS OF THIS DATE TO OWNER AND CONTRACTOR • THERE MAYBE ADDITIONAL COMMENTS FROM THE MECHANICAL REVIEWER. WILL FORWARD 5/31/2016 Comment: CONTRACTOR TO PAY THE REQUIRED PLAN REVIEW FEES UPON RE -SUBMITTAL OF COMPLETE PACKAGE PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 12/1612016 1211512015 1211512015 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Kevin Singley 12110/2015 12/10/2015 Comment: NEED TO PROVIDE A COMPLETE MECHANICAL PLAN FOR THIS PROJECT. PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 12/11/2015 5/3112016 613112016 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Cicio 1211012016 5/31/2016 513112016 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 1112312016 12/11/2015 Comment: 3 SETS OF SIGNED AND SEALED CIVIL DRAWINGS FOR CONSTRUCTABILITY REVIEW OF OUR ENGINEERING DEP. 12/11/2015 Comment: COPY OF THE FDOT PERMIT FOR THE DRIVEWAY TO US-1 t- Ji,• Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 8532 S U S 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3414-501-1903-20017 Zoning: CG APPLICATION INFORMATION Permit Number: 1511-0282 Permit Type: BUILDING COMMERCIAL REVIEW COMMENTS SCANNED BY St. Lucie Countv Owneris): Palm Park Center Llc Jurisdiction: ST LUCIE COUNTY Lot#: 3 Block: 3 Stories: Page 1 1 Automatic Sprinkler System? No Contractor Name: Eugene F Santoro Fax Number: Business Name: Coastal Development Inc Business Addr: 8509 S Federal Hwy Email: City / State / Zip: Port St Lucie, FI 34984 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Dale Completed Date Released ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 11/23/2015 1112312015 11/23/2015 Comment: DOCUMENTS MISSING PENDING Deanna Givens Comment: A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR WATER AND /OR SEWER OR A LETTER FROM THE 11/23/2015 UTILITY SERVICES PROVIDER STATING SERVICES ARE AVAILABLE(ABILITY TO CONNECT AT THE j SUBJECT LOCATION) 12/11/2015 Comment: SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICAL AND ROOF & SUB SUMMARY SHEET ENVIRONMENTAL REVIEW INCOMPLETE Ben Balcer 1111812015 Comment: ERD STAFF FOUND ACTIVE GOPHER TORTOISE BURROWS ONSITE. APPLICANT NEEDS TO APPLY FOR A 12/10/2015 RELOCATION PERMIT THROUGH THE FLORIDA FISH AND WILDLIFE (FWC) PRIOR TO THE ISSUANCE A VEGETATION REMOVAL PERMIT. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 1112312015 11/2312015 1112312015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 12/1512015 1211512015 1211512015 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE a Kevin Singley 1211012015 12/10/2015 Comment: NEED TO PROVIDE A COMPLETE MECHANICAL PLAN FOR THIS PROJECT. Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fox:(772)462.6443 REVIEW COMMENTS PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 12/11/2015 12/11/2015 Comment: PLEASE SHOW THE LOCATION OF THE WATER HEATER WHICH IS REQUIRED PER SECTION 607.1 OF THE FLORIDA PLUMBING CODE 2014 12111/2015 Comment: PLEASE SHOW THE URINAL AS A ACCESSABLE URINAL TO MEET ADA STANDARDS PER SECTION 605 OF THE FLORIDA ACCESSABILITY CODE 2014 12111/2015 Comment: PLEASE SHOW LOCATION OF SEPERATE SHUTOFF VALVES ON THE HOSE BIBS PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2014 PLANS EXAMINER REVIEW INCOMPLETE Joe Ciclo 1211012015 Comment: PLS SUBMIT THE [ ORIGINAL ] MANUFACTURERS ENGINEERED LAYOUTS AND CUT SHEETS FOR THE 12/10/2015 STEEL BAR JOIST SYSTEM AND BRIDGING REVIEWED AND APPROVED BY D.P. OF RECORD • NEED IN TRIPLICATE FOR REVIEW • SUBMIT SAME AS ABOVE FOR THE VULCRAFT STEEL ROOF DECKING SYSTEM Comment: PLS SUBMITTHE [ ORIGINAL ] MANUFACTURERS ENGINEERED LAYOUTS W/ CUT SHEETS FOR THE 12/10/2015 METAL ROOF TRUSSES REVIEWED AND APPROVED BY D.P. OF RECORD' NEED IN TRIPLICATE FOR REVIEW Comment: SUBMIT THE MANUFACTURERS ENGINEERED LAYOUTS AND DETAILS FOR THE LIGHT GAUGE METAL 12/10/2015 FRAMING SYSTEM INCLUSIVE OF ALL DETAILS, PLATES, FASTENERS AND ACCESSORIES REVIEWED AND APPROVED BY D.P. OF RECORD • NEED IN TRIPLICATE 12/10/2015 Comment: SUBMIT AN ORIGINAL SIGNEO,SEALED AND DATED SOIL TEST FOR REVIEW • SEE SHEET 16 REQUIREMENTS Comment: SHEET 16 IS DESIGNED TO EXPIRED CODES' GOVERNING CODE IS THE 2014 FBC, 5TH EDITION • PLS 12/10/2015 CHECK THAT ALL REFERENCE STANDARDS SPECIFIED ARE PERTAINING TO THE 2014 FBC, 5TH EDITION I.E. ACI 318-99 DOES NOT EXIST IN 2014 REFERENCE STANDARDS Comment: DESIGN LOAD COMPLIANCE SHEETS ARE INCOMPLETE • OCCUPANCY TYPES ARE B,M,S-2 AND F-2 • D.P. 12/10/2015 TO FILL IN RISK CATEGORY, ZONE 4,5 AND GARAGE OPENING PRESSURES, END ZONE CALCULATED WIDTH • NEED ORIGINALS IN TRIPLICATE 12/10/2015 Comment: SHEET 16 SPECIFYS [ 2 ] DIFFERENT CONCRETE STRENGTHS • PLS CLARIFY • IDENTIFY THE PSI FOR ALL HORIZONTAL AND VERTICAL WALL GROUT' SHEET 2 SPECIFYS 2500 P.S.I. ?? Comment: OCCUPANT LOADS ARE BASED ON A WHOLE NUMBER COUNT' PLS CORRECT THE SHEET 1 TABLES W/ 12/10/2015 PLUMBING TABLE' OCCUPANCIES ON SHEET 3 SHOULD BE SHOWROOM AS M / AND / OFFICE AS GROUP B 12/10/2015 Comment: SUBMIT TRIPLICATE, ORIGINAL COMMERCIAL ENERGY CALCULATIONS WITH TRIPLICATE MANUAL N EQUIPMENT SIZING CALCULATIONS FOR REVIEW 12/10/2015 Comment: SUBMIT A MASONRY DESIGN METHOD CHART ON PLANS PER FBC 2103 • INCLUDE ALL REFERENCE STANDARDS AND TESTING CRITERIA FOR PROPOSED MATERIALS 12/1012015 Comment: ENGINEER TO DESIGN THE CANVAS CANOPYS ON PLANS' SEE FBC 3105 • SUBMIT THE FABRIC SPECIFICATIONS FOR THE CANVAS Comment: SEE FBC 1004.6 FOR MULTIPLE OCCUPANCIES IN A BUILDING • ENGINEER TO DESIGN LIFE SAFETY PLANS ACCORDINGLY AND TO F.F.P.C. LIFE SAFETY' DO NOT USE DIAGONAL LINES •• DESIGN 12/10/2015 PROFESSIONAL HAS ALL EGRESS TO A SIDE DOOR MARKED ADA •• ADA MUST EXIT AT THE FRONT OF THE BUILDING WITHIN THE SAME AREA AS THE ACCESSIBLE PARKING • SHOW ALL CORRECT TRAVEL DISTANCES ON PLANS FROM ALL OCCUPANCIES 12/15/2015 Comment: SHOW ALL EGRESS SIZING AND CAPACITIES ON PLANS' FBC 1005 Comment: DESIGN PROFESSIONAL TO SHOW AN INTERIOR FINISHES TABLE ON PLANS PER FBC CHAPTER [8 ] 12/15/2015 SHOW ALL WALLAND CEILING FINISH CLASSIFICATIONS PER TABLE 803.9 W/ ALL SDI AND FLAME SPREAD FOR ALL FINISHES 803.1.1 • SHOW INTERIOR FLOOR FINISHES ON PLANS FBC 804 • SHOW ALL DETAILS AND TESTING REQUIREMENTS PER FBC 808 FOR THE ACOUSTICAL TILE CEILINGS ON PLANS 12/15/2015 Comment: SHOW THE FLAME SPREAD AND SDI FOR ALL INSULATION ON PLANS PER FBC 720 12115/2015 Comment: DESIGN PROFESSIONAL TO INCLUDE A GYPSUM BOARD, PLASTER AND ACCESSORY TABLE ON PLANS PER FBC CHAPTER 25 WITH ALL TESTING STANDARDS PER FBC TABLE 2506.2 12115/2016 Comment: SUBMIT THE TESTED DETAILS ON PLANS FOR THE WP 1551 FILE • CANNOT LOCATE THIS SYSTEM FOR THE 2 HOUR FIRE / SOUND WALL 1211512015 Comment: NOTE #3 SHEET [ 2 ] DOES NOT APPLY M1612015 Comment: SHOW THE TOILET AND BATHROOM REQUIREMENTS FINISH REQUIREMENTS ON PLANS PER FBC 1210 12/15/2015 Comment: SHOW ALL REQUIRED WINDOW AND DOOR FLASHING DETAILS ON PLANS PER FBC 1405.4 AT ALL AREAS AS PRESCRIBED IN THIS SECTION THAT APPLY M Planning S, Development Services Building S, Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL U982 Phone:V72)462.2172 Fax:(772)462.6443 REVIEW COMMENTS Comment: PRODUCT REVIEW AFFIDAVITS ARE INCOMPLETE • DESIGN PROFESSIONAL TO COMPLETE ALL AREAS INCLUDING THE OPENING D.P. AND METHODS OF ATTACHMENT • INCLUDE THE CORRECT PRODUCT APPROVAL NUMBERS FOR ALL CLADDING AS PERTINENT TO THIS BUILDING' STORE FRONT WINDOWS, 12115/2015 STORE FRONT DOORS, TRANSOMS, FOAM ROOF COVERINGS, OVERHEAD DOORS, TILE ROOFING COVERING DETAILS, SOLID SWING DOORS, RATED DOORS, ETC' NEED [ 31 PRODUCT REVIEW AFFIDAVITS S.S.D BY THE DESIGN PROFESSIONAL W/ PRODUCT APPROVALS AFFIXED " SEE FBC 1609.1.2.1 FOR THE LOUVER REQUIREMENTS AND SUBMIT MANUFACTURERS SPECIFICATIONS FOR REVIEW Comment: CALCULATE THE INCREASED LOADS ON PLANS COMPLIANT WITH FBC 1607.4 FOR FORKLIFTS AND 12/15/2015 MOVABLE EQUIPMENT WHEEL LOADS AND AS STATED IN 1607.7.4.1 FOR IMPACT AND FATIGUE ON THE FLOOR AND SUPPORTING STRUCTURE' SHOW ON PLANS FOR THE STORAGE AND FACTORY AREAS Comment: IF MECHANICAL EQUIPMENT WILL BE LOCATED ON THE ROOF SYSTEM SHOW DETAILS FOR THE 12115/2015 PERMANENT LADDER, CATWALKS AND GUARDRAILS PER FBCM 306.5' SHOW THE MECHANICAL STANDS, ATTACHMENTS AND EQUIUPMENT TIE DOWNS PER FBCM 301.15 Comment: SHOW THE SIZING CALCULATIONS ON THE PLANS FOR THE ROOF SCUPPERS IN ACCORDANCE WITH 12JI512015 THE 2014 PLUMBING CODES TABLE 1105.7 AND SHOW WHERE THE ROOF WATER WILL BE DISCHARGED TO 12/15/2015 Comment: SHOW THE SIZE AND REQUIRED WALL LOCATION FOR THE REQUIRED MALTESE CROSS ON PLANS. SEE FAC 69A-60 12/15/2015 Comment: SHOW THE DETAILS ON PLANS FOR THE EXTERIOR PLASTER APPLICATION PER FBC 2512 • SHOW ALL DETAILS AND TESTING REQUIREMENTS 12/15/2015 Comment: MUST MAINTAIN A MIN OF 36" WALK CLEARANCE AROUND THE BRIDGE SAW 12/15/2015 Comment: WHAT TYPE OF SOFFIT AND VENTILATION WILL BE INSTALLED IN THE RAISED TILE ROOF AREA' SHOW DETAILS ON PLANS Comment: CANNOT COMPLETE REVIEWS AT THIS TIME AS MUCH INFORMATION AND DOCUMENTATION IS MISSING 12115/2015 FROM THE ENGINEERS PLANS' PLEASE GO OVER ALL REQUIRED COMMENTS AND DOCS PRIOR TO RE - SUBMITTAL' WILL NEED [ 31 SETS OF ORIGINAL PLANS W/ [ 21 DISCS 12116/2015 Comment: COMMENTS E-MAILED TO CONTRACTOR AND OWNER AS OF THIS DATE ZONING REVIEW INCOMPLETE Lydia Galbraith 1112312015 12111/2015 Comment: 3 SETS OF SIGNED AND SEALED CIVIL DRAWINGS FOR CONSTRUCTABILITY REVIEW OF OUR ENGINEERING DEP. 12/11/2015 Comment: COPY OF THE FDOT PERMIT FOR THE DRIVEWAY TO US-1 rd Nq "- Planning& Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:)772)462-2172 Fax:)772)462.6"3 Page 2 Comment: PLEASE BE AWARE THAT WE WERE NOTABLE TO COMPLETE THE ZONING REVIEW DUE TO THE SITE PLAN EXTENSION NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE REVIEW 11/2312015 PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE AT THAT TIME. SCANNED BY St. Lucie Count, y-ti� 61-al ,-M6 alopi,"A-&-e , RECEIVED DEC / 3 2015