HomeMy WebLinkAboutPLANS 1SCOPE OF WORK: DESIGNED PER:
PVSTRUCTURAL PLAN ASCE7
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED
WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY My
SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.
ENGINEER
0
V
Q U
W
F- W
Z Q.
LD TD
w
� N
G (�
z 3
0 3
E
7
r
W PULL INSTALLATION PLAN
THIS'PAPEW PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAWNG JURISDICTION
AM BUILDING DEPARTMENT)AND INSTALLERS. USERS ME ENCOURAGED TO ACCESS W (ELECTRONIC VERSION) OF THIS PLAN.
ACTME HYPERUNXS ON W PROVIDE EASYACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDYTHE
FILM AND OEM (ORIGINAL EQUIPMENT MANUFACTURER) DETAILS AT MAGNIFICATIONS OF MEWER CHOICE UP TO 6400%. IF
CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL OEM SHALL PREVAIL
1. THIS PLAN IS FOR SINGLE FAMILY RESIDENUAL PROJECTS ONLY. MULTI -FAMILY & COMMERCIAUINDUSTRIAL PROJECTS
REQUIRE SITE-SPECI RC PLANS
2. THIS PLAN SHALL BE USED SOLELY FOR PROJECTS IN AREAS WHERE WINDSPEED IS Wit 170-MPH OR LESS.INSTAIIATIONS
IN HIGHER WIND AREAS SHALL REQUIRE SITE -SPECIFIC ENGINEERING.
3. SEE EVEREST RAIL SELECTION CHART FOR ROOF ATTACHMENT SPACING.
THIS PLAN OFFERS TWO INSTAUATION METHODS:
I. FRAMING
2. SHEETING
MINIMUM FASTENERS @ EACH ROOF ATTACHMENT SHALL BE STAINLESS STEEL AS FOLLOWS:
• FRAMING -SINGLE 5/16 DIAMETER LAG INTO CENTER OFFRAMING WITH}INCH THREAD EMBEDMENT.
• SHEETING- FOUR# 12 SMS(SHEET METALSCREW) 2-INCH LONG
FDSHINGS:
• FRAMING -SEE DRAWING &PHOTO IMAGES.ACCEPTABIEALTERNATE FIASHINGS INCLUDE 9-INCH BYS-INCH 28-GAUGE
(MINIMUM) ALUMINUM SHEET.
• SHEETING ATTACHMENT ISSEIFFUISHING. SEE htt :// lelman e.com/Solaar33//PPCCM-0MS%20PV%205TRUCTUML IN
EOR(ENGINEER OF RECORD) PREFERS EMAILCAMMU�IA; ALLE G-AWIMANPE.g
lead
Root Dope 7 - 27 0e
Roof Slope 27-45 Degrees
Rol Spans - Zme 1, 4p 3
flan Spona
- Sme 1,
hP B
Sla. (Pa0
M 4 (mph)
v 6'
8'
4'
6'
8'
0
10
110
OR 48-S -
LORI/
fOF=RGfiOOFATTCHIMTSPAC&
ROOF='R<30{t&SLOPE<300EL0.'IS
P22N�4'{M3
rf
- --
-CR 48-S
2'
NR�
TD7as
3a
- U80
/I
--
130
CR 80
SUDPEN30GUE
NGT
T.10
V TB
no
170
w1a
CR 48
ON
Sl�
al
20
'
TQVLiT��.3f.
o Ta
'T44Ls
a
a
s
sso
01 Q
30
110
mau,,jaw
Ai rr>
IDR'I
13oNOISLAMomal
no
170
40
110
130
no
-
170
50
110
XEY
485
48
80
KEY
485
48
80
_ - _
130'
ISO
170
amsw=emmP+�..vwme. m,ww,we�m�pm�eaaaimw%+mwwmann�.
- EVERESTTM RAIL SELECTION CHART.
OS sruz: x/A
� Y
UNIVERSAL MIDDLE CLAMP SET UNIVERSAL END CLAMP SET
EVEREST CLAMPS ARE UL 2703 LISTED AS PROVIDING ALL REQUIRED
BONDING/GROUNDING OF PV MODULES TO EVEREST RAILS.
0EVERESTTM CLAMPING SYSTEMS CLAMPING SYSTEMS.
� SfdIL X/A
ANY FSEC CERTIFIED PV
MODULE, LANDSCAPE OR TYP. RIDGE PM PER ASCE)
PORTRAR
PZ3
PZ3
-e
— - - - - - -
e o
PZ
2
a
ROOF
•�
o
e.
(ROOF
.•.
d
PZ2
L'PZ3
PZ2 P 3Jj
YP.EAVE
RooFvaDTH
(-'
ALLEN GE U AN
16502 MNNA RD.
LU Z, FLORIDA 33M9
A
PH.813 9091956
Allen@GezelmMPE.m
Yn)M.GezelmanPE=m
PE 59180
IseyAHELE4S9"L.SFEI�
' 15
�---rvDimemmm
B
EVERESTPVRAIL
02
TyPICPL RNLd MOVMINGSYSTEM.
03
F,,, T ROOFWINOPMSSUREZONEGPERMC4014(S'EDRION) _(if! ' Z
s4D: x/A
waz:xrs
1 LOIY
DRAFTSMAN:
EFROP9wsuuAr reuovroua suwmalsRamweuowEeuwwxsxwm
ALPERICELI
APPLICABLE CODE:
=NgwFFEMHD6
HE ERB EYOM noowu�oEomlmhEmxmrunoswemAcronv n art ewcM Enlrroe
M1NNYVNDTFHISPRPMLlm.E4Tc111EIIMGERY9ITNN WYNOi W0.GECM1YMgGiEWIENMLgIMEM
8 Pe celi@maiLustedu
FBC EDITION) FLORIDA BUILDING CODE
SLT2wNASD 15n9 MPH, FERR, EXPOSURE D, MID
w� GPROPEmr.awsRAcmRREswxsmlErovEM PrvMEswowreurosxmMewwsrauiwxawmvro
2014 (5TM
SGLFLY
APPROVED SEALANT
RFAOYFORSENANT
REAOYFORWRNL
eM FOUND ALUMABLE RDIFAC TESTED
aMETALROOFATTAGHMET
swe xrs
TILER SINGLE-0LYGHEERNG ATTACIIMFM BHINGLE FRAMINGAITAGIQIEM
07 —_:.A. 11 u•,.. rVA
J"xlo
FENDER
WASHER
18 5S HIX NUT \
�MIPQAMP SET WST.
PV MODULE ROOF
TILE
PV RA .
FLASHING
COMPOSITION SHINGLE
ROOF FRAMING
A"x 6.5S HANGE6IGAN N ED
(MIN. 2.5"EMBED) BY
't Lucie County
ROOF MOUNTING DETAILCOMMSRION SHIN-
09 FLASHING, RAIL.& SHEETING APPEAWWCE MAY VARY.
..,•: xrs
xj HEX HEAD BOLT
RMSEBOLT
ROOF STANDOFF
� �—MLN.4 k12X2'SMS-SS
St.
WATER PROOFING WITH SONOUSTIC
NP-1 OR EQUAL POLYURETHANE MILK
10 SHEETING ATTACHMENT
sr.., xrs
re
D
S-5!
CLAMP
LIER:
SYBTEMSLLF
CBLVO5Ort111E
7).lSP4..
TRA
CLAMP
ACE
CLAMP
APPROVED STAND W G SEAM CLMlPS
12 v WA