Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SCANNED ® Building & Code Regulations Division BY • 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462Ek5L e COUn ty Certification for Design Load Compliance Project Name: Harbour Ridge LifeStyle Center, Harbour Ridge Yacht & Country Club Project Address: 12600 Harbour Ridge Blvd., Palm city, FL 34990 Permit#: Occupancy Type: COmmefcialConstructionType: INSTRUCTIONS FOR USE• • This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official- Contactthe # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with.20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): __I_Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B C C _D 4. Design Wind Velocity 162 .mph _ASD X LRFD End Zone Width: 9 ft 5. Mean Roof Height 18 ft Roof Pitch: 7 .12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 47.4 Zone 2: 55.4 Zone 3: 55A Zone 4: 48.8 Zone 5: 58.2 Garage: 58.2 7. Design Loads: Floor: 250 PSF Roof/Dead: � PSF Roof/Live: 20 Balcony: -EA_PSF Dock: N/A PSF Deck: PI/A PSF Stairs: 100 .PSF Fence: N/A PSF Railings: 50 PLF PSF 8. Were Shear Walls Considered. For Structure? -X__Yes _Not Applicable -ExplainWhyNot: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of tilnpjy�,codes currently adopted and enforced by St. Lucie County. I also certify that structural elemer% 6h thei4ans provide adequate resistance to the design forces specified: �� �fi s•••• •••••• A ti un Oil A %411%. 5454 Cent It & Co. Cert Auth. Signature, Date, and Seal Revised 07/25/2014 ^3 REC '70 3 201016 Planning & Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Harbor Ridge Life Style Center, Harbour Ridge Yacht & Country Club ProjectAddreess: 13400 Gilson Road, Palm City, FL Permit#: �✓I Occupancy Type: Commercial Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III —IV Exposure Category: B X C _D 4. Design Wind Velocity 162 mph _ASD X LRFD End Zone Width: 9 ft 5. Mean Roof Height 19 ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 47.4 Zone 2: 55.4 Zone 3: 55.4 Zone 4: 48.8 Zone 5: 58.2 Garage: 58.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: 100 PSF Fence: n/a PSF Railings: 50 Of PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: `0.a1tt't'slit, a", o W..�.,� 5454 22 �� PrNa e Cert # & Co. Cart Auth. r7 0 0 0•_ m o:¢2 °"'^^ mmm .�...�,...•,..-.-.-..-�..�w...� `- z U, F- Oy Signature, Date, ana Seai RGD Con Z cC awn Rd, Suite 104, Jupiter, FL 33458 Compan �'.,e ''•..... •QF���` 11111111101 Revised 07/25/2014 RECEIVED ' 20 2616 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Harbor Ridge Life Style Center, Harbour Ridge Yacht & Country Club Project Address: 13400 Gilson Road, Palm City, FL Permit#: IS/1—MOH Occupancy Type: Commercial Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III —IV Exposure Category: _B X C D 4. Design Wind Velocity 162 mph _ASD X LRFD End Zone Width: 9 ft 5. Mean Roof Height 19 ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 47.4 Zone 2: 55.4 Zone 3: 55.4 Zone 4: 48.8 Zone 5: 58.2 Garage: 58.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: Na PSF Dock: n/a PSF Deck: n/a PSF Stairs: 100 PSF Fence: n/a PSF Railings: 50 plf PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Ut/enf ,��is Hai 0,��� 5454 ' Print ......���. Signature, Date, ana Seal RGD Can W C, 'yam roCO�: Compan ""111 Iu11111" Revised 07/25/2014 Cert # & Co. Cent Auth. )wn Rd, Suite 104, Jupiter, FL 33458 RECEI`.':D JAN ' M6 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Harbor Ridge Life Style Center, Harbour Ridge Yacht & Country Club Pro)ectAddress:13400 Gilson Road, Palm City, FL Permit#: 1es0— 0Gfoq Occupancy Type: Commercial Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: B X C D 4. Design Wind Velocity 162 mph ASD X LRFD End Zone Width: 9 ft 5. Mean Roof Height 19 ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 47.4 Zone 2: 55.4 Zone 3: 55.4 Zone 4: 48.8 Zone 5: 58.2 Garage: 58.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: 100 PSF Fence: n/a PSF Railings: 50 Of PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not 10. -Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Signature, Date, ano beai Wenji �.•° ..... 5454 Print Na LL 6•.2,'._ Cert # & Co..Cert Auth. 0 0 W � F o Fa Z ul RGD Con Compan -li,�� "* iwn Rd, Suite 104, Jupiter, FL 33458 Revised 07J25/2014 Planning & Development Services Department Building& Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: Harbour Ridge LlfeStyle Center,. Harbour Ridge Yacht & Country Club Project Address: 12600 Harbour Ridge Blvd., Palm city, FL 34990 Permit#: Occupancy Type: Commercial construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contactthe # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Cade Fifth Edition with 20 14 Supplements using ASCE 7-10 2_ Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X 11 _III _ IV . Exposure Category: _B C C _D 4. Design Wind Velocity 162 mph _ASD X LRFD End Zone Width: 9 ft 5. Mean Roof Height 1 B ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 47.4 Zone 2: 55.4 Zone 3: 55,4 Zone 4: 48.8 Zones: 58.2 Garage: 58.2 7. Design Loads: Floor. 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: WA PSF Dock: N/A PSF Deck: N/A PSF Stairs: 1 00 PSF Fence: N/A PSF Railings: 50 PLF pSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? —X—Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT• I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions ,+tkg®j�qcodes currently adopted and enforced by St. Lucie County. I also certify that structural elemer jWo}o A them vans provide adequate resistance to the design forces specified: a�:•'i N S Ems' . �L 41 $ 5454 Cert # & Co. Cert Auth. Signature, Date, and Seal Revised 07/25/2014 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: Harbour Ridge LifeStyle Center, Harbour Ridge Yacht & Country Club Project Address: 12600 Harbour Ridge Blvd., Palm city, FL 34990 Permit#: Occupancy Type: Commercialconstruction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ` Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contactthe # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 supplements using ASCE 7-10 2. Structure Designed as (check one): -X_Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _IV Exposure Category.• _B C C _D 4. Design Wind Velocity t 62 mph _Aso X LRFD End Zone Width: 9 ft S. Mean Roof Height tB ft Roof Pitch: 7 :12 Parapet n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on losqft @ 15'MRH, clearly label on all plan openings): Zone 1: 47-4 Zone 2: 55.4 Zone 3: 55,4 Zone 4: 48.8 Zones: 58.2 Garage: 58.2 7. Design Loads: Floor. 250 PSF Roof/Dead: � PSF Roof/Live: 20 Balcony: wA PSF Dock: N/A PSF Deck: N/A PSF Stairs: 100 PSF Fence: N/A PSF Railings: 50 PLIF SF S. Were Shear Walls Considered For Structure? -X—Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? ? Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions �*JkO t#WN,,� des currently adopted and enforced by St. Lucie County. I also certify that structural elemer �h thesbj�ans provide adequate resistance to the design forces specified; �J?i��'� ......... N S E •• un 5454 inn me _ Cert # & Co. Cert Auth. ,r .Lu� Signature, Date, and Seal ��� y�7� {raQfl,$1�61�•�neers Revised 07/25/2ol4