Loading...
HomeMy WebLinkAboutREVIEW COMMENTSt .,, ,��LrfilPi- tid Planning& Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(77214626443 PROPERTY INFORMATION Address: 13400 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel #: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0404 Permit Type: COMMERCIAL RENOVATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City I State / Zip: Vero Beach, FI 32960 , REVIEWS AND COMMENTS REVIEW COMMENTS SCANNED BY St. Lucie Cou 9 p Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Type Status Reviewed By Date Started Data Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 12/8/2015 Comment: VEG PERMIT IN DRAWER UNDER (H) FOR HARBOR RIDGE YACHT & COUNTRY CLUB -A HUMPHREY 3/31/2016 Comment: VEG PERMIT IN BIN UNDER "H" ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1/2612016 1/26/2016 1/2612016 Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 1277120115 12/712015 Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW PENDING Lashahna Ingram 1112612015 Comment: PE REVIEW COMMENTS (2) COMPLETE Ed Roseberry 31812016 4/112016 41112016 Comment: PE REVIEW COMMENTS (3) INCOMPLETE Ed Roseberry 414/2016 4/4/2016 Comment: PLEASE SUBMIT 2 DIGITAL SETS OF CORRECTED PLANS. PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 1211512015 12128/2015 12128/2015 Comment: a Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, Fl- 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 2 PLANS EXAMINER MECHANICAL COMPLETE Kevin Singley '12110120'15 12/10/2015 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 1211412015 12/14/2015 Comment: PAGE LS-101 HAS THE WRONG CODE REFRENCED,WE ARE NOW USING THE 2014 CODES PLEASE CORRECT ON PLANS Comment: PLEASE INDICATE WHAT TYPE OF SEWAGE DISPOSAL SYSTEM THIS BLD WILL BE ON. FOR EXAMPLE ON SITE SEWAGE TREATMENT OR COUNTY OR CITY SEWAGE TREATMENT.YOU WILL NEED TO HAVE GREASE 12/14/2015 INTERCEPTER APPROVED BY HEALTH DEPT IF IT IS ON SITE (SECTION 1003 FL PLUMBING CODE 2010) OR UTILITY COMPANY IF CITY OR COUNTY UTILITY. Comment: PLEASE SHOW SO FOOTAGE OF ROOF AND RAINFALL RATE FOR EACH ROOF DRAIN PER CHAPTER 11 OF 12/14/2015 THE FLORIDA PLUMBING CODE 2014. Comment: PLEASE SHOW ON PLANS WHAT IS DRAINING INTO THE FLOOR SINK LOCATED BY THE DOORI ROOM 12114/2016 NUMBER 1007. YOU LIST THIS ROOM AS STORAGE. 12/14/2015 Comment: PLEASE SHOW TRAP PRIMERS ON EMERGENCY FLOOR DRAINS PER SECTION 1002.4 OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW COMPLETE Ed Roseberry 12/10/2015 3/10/2016 3110/2016 Comment: ZONING REVIEW COMPLETE Jeffrey Johnson 121312015 12/4/2015 1214/2015 Comment: Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 13400 Gilson Rd City / State I Zip: Palm City, A 34990 Parcel #: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0404 Permit Type: COMMERCIAL RENOVATION REVIEW COMMENTS SCANNED BY St. Lucie Countv 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Fax Number: 772-234-8188 Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 Email: Dtolliver@Proctorcc.Com City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Data Released DOCUMENTS MISSING PENDING Lashahnaingram 12/8/2015 Comment: VEG PERMIT IN DRAWER UNDER (H) FOR HARBOR RIDGE YACHT & COUNTRY CLUB -A HUMPHREY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 112612016 1/2612016 1/2612016 Comment: ENVIRONMENTAL REVIEW Comment: FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) 2/1/2016 Comment: 2/1/2016 Comment: 2/1/2016 Comment: 2/1/2016 Comment: APPROVED Jennifer Evans 121712015 1217/2015 PENDING PENDING Lashahna Ingram 11/2512015 INCOMPLETE Ed Roseberry 3/812016 PLEASE SUBMIT LETTER FROM THRESHOLD INSPECTOR AND STRUCTURAL INSPECTION PLAN COMPLYING WITH FBC CH. 110.8 PLEASE SUBMIT LIST OF ALL PERSONS PERFORMING INSPECTIONS WITH SPECIAL INSPECTOR, INCLUDING LICENSE NUMBERS, COMPLYING WITH FBC CH. 110.8.6 PLEASE LOCATE ON PLANS, AND SHOW OCCUPANT LOADS, FOR CLASSROOMS/VOCATIONAL ROOMS NOTED ON SHEET LS 101. PLEASE INCLUDE OCCUPANT LOADS FOR VESTIBULES, LOBBYS, ETC, IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE INCLUDE SHOP DRAWINGS FOR SHIP LADDER TO MEZZANINE. r 56% Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 2 2/1/2016 Comment: PLEASE INCLUDE PRODUCT APPROVAL AFFIDAVIT, OR PRODUCT APPROVALS, FOR ALL COMPONENTS USED IN THE STRUCTURAL ENVELOPE OF PROJECT. 2/112016 Comment: PLEASE INCLUDE 2 SETS OF TRUSS SHOP DRAWINGS FROM TRUSS MANUFACTURER. 2/1/2016 Comment: PLEASE SUBMIT 2 TRUSS MANUFACTURERS LAYOUT SHEETS, REVIEWED AND APPROVED BY DESIGN PROFESSIONAL. 319/2016 Comment: VESTIBULES ARE, BY DEFINITION IN SEVERAL DICTIONARYS, LOBBYS, AND THEREFORE HAVE AN OCCUPANCY. PLEASE SHOW CORRECT OCCUPANT LOAD FOR ALL VESTIBULES. 3110/2016 Comment: PLEASE REMOVE REFERENCES IN OCCUPANCY LOAD SECTION OF SHEET LS-101 TO CLASSROOMS, SHOPS, AND VOCATIONAL ROOMS IF NONE EXIST, AS STATED IN YOUR RESPONSE SUMMARY. 3/10/2016 Comment: PLEASE SHOW CORRECT OCCUPANT LOAD FOR BARBOR SHOP, 1056. 3/10/2016 Comment: PLEASE SHOW CORRECT OCCUPANT LOAD FOR ELECTRICAL ROOM 1077. 3/1012016 Comment: PLEASE SHOW CORRECT OCCUPANT LOAD FOR MECHANICAL ROOM 1078. 3/10/2016 Comment: PLEASE SHOW CORRECT OCCUPANT LOAD FOR MECHANICAL MEZZANINE 2001. 3/1012016 Comment: PLEASE SHOW CORRECT OCCUPANT LOAD FOR JANITOR ROOM 1012. 3/10/2016 Comment: PLEASE SHOW COMPLIANCE WITH THRESHOLD BUILDING REQUIREMENTS REFERENCED ABOVE. PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 1211512015 1212812015 12128/2015 Comment: PLANS EXAMINER MECHANICAL COMPLETE Kevin Singley 1211012015 12/10/2015 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 12/14/2015 12/1412015 Comment: PAGE LS-101 HAS THE WRONG CODE REFRENCED,WE ARE NOW USING THE 2014 CODES PLEASE Comment: 12/14/2015 12/14/2015 Comment: 12114/2015 Comment: 1211412015 Comment: PLANS EXAMINER REVIEW Comment: ZONING REVIEW Comment: CORRECT ON PLANS PLEASE INDICATE WHAT TYPE OF SEWAGE DISPOSAL SYSTEM THIS BLD WILL BE ON. FOR EXAMPLE ON SITE SEWAGE TREATMENT OR COUNTY OR CITY SEWAGE TREATMENT.YOU WILL NEED TO HAVE GREASE INTERCEPTER APPROVED BY HEALTH DEPT IF IT IS ON SITE (SECTION 1003 FL PLUMBING CODE 2010) OR UTILITY COMPANY IF CITY OR COUNTY UTILITY. PLEASE SHOW SQ FOOTAGE OF ROOF AND RAINFALL RATE FOR EACH ROOF DRAIN PER CHAPTER 11 OF THE FLORIDA PLUMBING CODE 2014. PLEASE SHOW ON PLANS WHAT IS DRAINING INTO THE FLOOR SINK LOCATED BY THE DOORI ROOM NUMBER 1007. YOU LIST THIS ROOM AS STORAGE. PLEASE SHOW TRAP PRIMERS ON EMERGENCY FLOOR DRAINS PER SECTION 1002.4 OF THE FLORIDA PLUMBING CODE 2014. INCOMPLETE Ed Roseberry 12/10/2015 COMPLETE Jeffrey Johnson 12/3/2015 1214/2015 12/412015 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6448 PROPERTYINFORMATION Address: 13400 Gilson Rd City I State / Zip: Palm City, FI 34990 Parcel#: 4425-701-0016-00014 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0404 Permit Type: COMMERCIAL RENOVATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State I Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS REVIEW COMMENTS SCANNED BY St. Lucie Col r 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 121812015 Comment: VEG PERMIT IN DRAWER UNDER (H) FOR HARBOR RIDGE YACHT 8 COUNTRY CLUB -A HUMPHREY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1/2612016 112612016 1/2612016 Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 121712015 12f7/2015 Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW PENDING Lashahna Ingram 11/25/2015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 1211512015 12/28/2015 1212812015 Comment: PLANS EXAMINER MECHANICAL COMPLETE Kevin Singley 12JI012015 12110/2016 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 12/14/2016 12114/2015 Comment: PAGE LS-101 HAS THE WRONG CODE REFRENCED,WE ARE NOW USING THE 2014 CODES PLEASE CORRECT ON PLANS Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS t;omment: PLEASE INDICATE WHAT TYPE OF SEWAGE DISPOSAL SYSTEM THIS BUD WILL BE ON. FOR EXAMPLE ON 12/14/2015 SITE SEWAGE TREATMENT OR COUNTY OR CITY SEWAGE TREATMENT.YOU WILL NEED TO HAVE GREASE INTERCEPTER APPROVED BY HEALTH DEPT IF IT IS ON SITE (SECTION 1003 FL PLUMBING CODE 2010) OR UTILITY COMPANY IF CITY OR COUNTY UTILITY. 12/14/2015 Comment: PLEASE SHOW SQ FOOTAGE OF ROOF AND RAINFALL RATE FOR EACH ROOF DRAIN PER CHAPTER 11 OF THE FLORIDA PLUMBING CODE 2014. 12/1412015 Comment: PLEASE SHOW ON PLANS WHAT IS DRAINING INTO THE FLOOR SINK LOCATED BY THE DOORI ROOM NUMBER 1007. YOU LIST THIS ROOM AS STORAGE. 12114/2015 Comment: PLEASE SHOW TRAP PRIMERS ON EMERGENCY FLOOR DRAINS PER SECTION 1002.4 OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW INCOMPLETE Ed Roseberry 1211012015 114/2016 Comment: PLEASE NOTE THIS REVIEW IS NOT COMPLETE, BUT IS BEING SENT AT THE REQUEST OF MIKE O'NEAL. OTHER COMMENTS ASSOCIATED WITH THIS REVIEW WILL FOLLOW SHORTLY. 211/2016 Comment: PLEASE INCLUDE ALL CURRENT CODE EDITIONS IN DESIGN CRITERIA BLOCK(S). 211/2016 Comment: PLEASE SUBMIT LETTER FROM THRESHOLD INSPECTOR AND STRUCTURAL INSPECTION PLAN COMPLYING WITH FBC CH. 110.8 2/1/2016 Comment: PLEASE SUBMIT LIST OF ALL PERSONS PERFORMING INSPECTIONS WITH SPECIAL INSPECTOR, INCLUDING LICENSE NUMBERS, COMPLYING WITH FBC CH. 110.8.6 211/2016 Comment: PLEASE SHOW ALL REQUIRED PROTECTION OF BUILDING ELEMENTS, COMPLYING WITH FBC CH. 6 AND TABLE 601, ASSOCIATED WITH TYPE III A CONSTRUCTION. 21112016 Comment: PLEASE LOCATE ON PLANS, AND SHOW OCCUPANT LOADS, FOR CLASSROOMS/VOCATIONAL ROOMS NOTED ON SHEET LS 101. 211/2016 Comment: PLEASE SHOW RATED ASSEMBLY SEPERATION AT MECHANICAL ROOM 1078. 2/1/2016 Comment: PLEASE NOTE AREAS 1080 AND 1085 IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE INCLUDE OCCUPANT LOADS FOR VESTIBULES, LOBBYS, ETC, IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE SHOW DETAIL OF REFERENCED MEZZANINE CEILING ASSEMBLY, NOTED ON SHEETS A403 AND A404 211/2016 Comment: REFERENCED SHEET A909 APPEARS TO BE MISSING. 211/2016 Comment: PLEASE INCLUDE SHOP DRAWINGS FOR SHIP LADDER TO MEZZANINE. 2/1/2016 Comment: PLEASE INCLUDE PRODUCT APPROVAL AFFIDAVIT, OR PRODUCT APPROVALS, FOR ALL COMPONENTS USED IN THE STRUCTURAL ENVELOPE OF PROJECT. 211/2016 Comment: PLEASE INCLUDE 2 SETS OF TRUSS SHOP DRAWINGS FROM TRUSS MANUFACTURER. 211/2016 Comment: PLEASE SUBMIT 2 TRUSS MANUFACTURERS LAYOUT SHEETS, REVIEWED AND APPROVED BY DESIGN PROFESSIONAL. ZONING REVIEW ' COMPLETE Jeffrey Johnson 1213/2015 1214/2015 1214/2015 Comment: V 111' w w Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 13400 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel#: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0404 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS REVIEW COMMENTS SCANNED BY St. Lucie Countv 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tvoe Status Reviewed By Date Started Date Comoleted Date Released DOCUMENTS MISSING PENDING Lashahna Ingram ' 11125/2016 Comment: NEEDS SUBS FOR ALL TRADES HVAC,PLUMBING, ELECTRICAL,& ROOFING 11125/2015 Comment: NEEDS SUB SUMMARY 1218/2015 Comment: VEG PERMIT IN DRAWER UNDER (H) FOR HARBOR RIDGE YACHT & COUNTRY CLUB -A HUMPHREY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1/2612016 1126/2016 1/26/2016 Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 121`/12015 1217/2015 Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW PENDING Lashahna Ingram 1112512016 I Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 1211512015 12128/2015 12/2812016 Comment: PLANS EXAMINER MECHANICAL COMPLETE Kevin Singlay 12/1012015 12/10/2015 Comment: it 0% w w iraicou�ti Planning & Development Services Building & Code RegulatIon Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS 2 rL NO =R INCK YLUMCINU INCOMPLETE Greg Smyth 12114/2015 12114/2015 Comment: PAGE LS-101 HAS THE WRONG CODE REFRENCED,WE ARE NOW USING THE 2014 CODES PLEASE CORRECT ON PLANS Comment: PLEASE INDICATE WHAT TYPE OF SEWAGE DISPOSAL SYSTEM THIS BUD WILL BE ON. FOR EXAMPLE ON 12/14/2015 SITE SEWAGE TREATMENT OR COUNTY OR CITY SEWAGE TREATMENT.YOU WILL NEED TO HAVE GREASE INTERCEPTER APPROVED BY HEALTH DEPT IF IT IS ON SITE (SECTION 1003 FL PLUMBING CODE 2010) OR UTILITY COMPANY IF CITY OR COUNTY UTILITY. 1211412015 Comment: PLEASE SHOW SQ FOOTAGE OF ROOF AND RAINFALL RATE FOR EACH ROOF DRAIN PER CHAPTER 11 OF THE FLORIDA PLUMBING CODE 2014. 12/14/2015 Comment: PLEASE SHOW ON PLANS WHAT IS DRAINING INTO THE FLOOR SINK LOCATED BY THE DOORI ROOM NUMBER 1007. YOU LIST THIS ROOM AS STORAGE. 1211412015 Comment: PLEASE SHOW TRAP PRIMERS ON EMERGENCY FLOOR DRAINS PER SECTION 1002.4 OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW INCOMPLETE Ed Rcseberry 12110/2015 1/4/2016 Comment: PLEASE NOTE THIS REVIEW IS NOT COMPLETE, BUT IS BEING SENT AT THE REQUEST OF MIKE O'NEAL. OTHER COMMENTS ASSOCIATED WITH THIS REVIEW WILL FOLLOW SHORTLY. 2/1/2016 Comment: PLEASE INCLUDE ALL CURRENT CODE EDITIONS IN DESIGN CRITERIA BLOCK(S). 2/1/2016 Comment: PLEASE SUBMIT LETTER FROM THRESHOLD INSPECTOR AND STRUCTURAL INSPECTION PLAN COMPLYING WITH FBC CH. 110.8 2/1/2016 Comment: PLEASE SUBMIT LIST OF ALL PERSONS PERFORMING INSPECTIONS WITH SPECIAL INSPECTOR, INCLUDING LICENSE NUMBERS, COMPLYING WITH FBC CH. 110.8.6 2111201E Comment: PLEASE SHOW ALL REQUIRED PROTECTION OF BUILDING ELEMENTS, COMPLYING WITH FBC CH. 6 AND TABLE 601, ASSOCIATED WITH TYPE III A CONSTRUCTION. 2/1/2016 Comment: PLEASE LOCATE ON PLANS, AND SHOW OCCUPANT LOADS, FOR CLASSROOMSNOCATIONAL ROOMS NOTED ON SHEET LS 101. 2/1/2016 Comment: PLEASE SHOW RATED ASSEMBLY SEPERATION AT MECHANICAL ROOM 1078. 2/1/2016 Comment: PLEASE NOTE AREAS 1080 AND 1085 IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE INCLUDE OCCUPANT LOADS FOR VESTIBULES, LOBBYS, ETC, IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE SHOW DETAIL OF REFERENCED MEZZANINE CEILING ASSEMBLY, NOTED ON SHEETS A403 AND A404 2/1/2016 Comment: REFERENCED SHEET A909 APPEARS TO BE MISSING. 2/1/2016 Comment: PLEASE INCLUDE SHOP DRAWINGS FOR SHIP LADDER TO MEZZANINE. 211/2016 Comment: PLEASE INCLUDE PRODUCT APPROVAL AFFIDAVIT, OR PRODUCT APPROVALS, FOR ALL COMPONENTS USED IN THE STRUCTURAL ENVELOPE OF PROJECT. 211/2016 Comment: PLEASE INCLUDE 2 SETS OF TRUSS SHOP DRAWINGS FROM TRUSS MANUFACTURER. 2/112016 Comment: PLEASE SUBMIT 2 TRUSS MANUFACTURERS LAYOUT SHEETS, REVIEWED AND APPROVED BY DESIGN PROFESSIONAL. ZONING REVIEW COMPLETE Jeffrey Johnson 12/312015 1214/2016 121412015 Comment: 01 w w a Planning &Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 13400 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel#: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0404 Permit Type: COMMERCIAL RENOVATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, LIc Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS SCANNED BY REVIEW COMMENTS St. Lucie Count,, Page 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Typ Status Reviewed By Date Started Date Comoleted Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11/25/2015 Comment: NEEDS SUBS FOR ALL TRADES HVAC,PLUMBING, ELECTRICAL,& ROOFING 11125/2015 Comment: NEEDS SUB SUMMARY 1218/2015 Comment: VEG PERMIT IN DRAWER UNDER (H) FOR HARBOR RIDGE YACHT & COUNTRY CLUB -A HUMPHREY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1/26/2016 1/26/2016 1/26/2016 Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 12f7/2015 1217/2015 Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW PENDING Lashahna Ingram 11/2512015 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 1211512015 12/28/2015 12/28/2015 Comment: PLANS EXAMINER MECHANICAL COMPLETE Kevin Singley 1211012015 1211012015 Comment: Planning B, Development Services REVIEW COMMENTS Building 8, Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 Page 2 III ALI^ .----- _._....... _.-. __... _..... ..........r�uc WIVU anryrn lalwul5 12/14/2015 Comment: PAGE LS-101 HAS THE WRONG CODE REFRENCED,WE ARE NOW USING THE 2014 CODES PLEASE CORRECT ON PLANS Comment: PLEASE INDICATE WHAT TYPE OF SEWAGE DISPOSAL SYSTEM THIS BLD WILL BE ON. FOR EXAMPLE ON 12/14/2016 SITE SEWAGE TREATMENT OR COUNTY OR CITY SEWAGE TREATMENT.YOU WILL NEED TO HAVE GREASE INTERCEPTER APPROVED BY HEALTH DEPT IF IT IS ON SITE (SECTION 1003 FL PLUMBING CODE 2010) OR UTILITY COMPANY IF CITY OR COUNTY UTILITY. 12/14/2015 Comment: PLEASE SHOW SQ FOOTAGE OF ROOF AND RAINFALL RATE FOR EACH ROOF DRAIN PER CHAPTER 11 OF THE FLORIDA PLUMBING CODE 2014, 1211412015 Comment: PLEASE SHOW ON PLANS WHAT IS DRAINING INTO THE FLOOR SINK LOCATED BY THE DOORI ROOM NUMBER 1007. YOU LIST THIS ROOM AS STORAGE. 12/1412015 Comment: PLEASE SHOW TRAP PRIMERS ON EMERGENCY FLOOR DRAINS PER SECTION 1002A OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW INCOMPLETE Ed Roseberry 1211012015 1/4/2016 Comment: PLEASE NOTE THIS REVIEW IS NOT COMPLETE, BUT IS BEING SENT AT THE REQUEST OF MIKE O'NEAL. OTHER COMMENTS ASSOCIATED WITH THIS REVIEW WILL FOLLOW SHORTLY. 2l1/2016 Comment: PLEASE INCLUDE ALL CURRENT CODE EDITIONS IN DESIGN CRITERIA BLOCK(S). 2t1/2016 Comment: PLEASE SUBMIT LETTER FROM THRESHOLD INSPECTOR AND STRUCTURAL INSPECTION PLAN COMPLYING WITH FBC CH. 110.8 2/1/2016 Comment: PLEASE SUBMIT LIST OF ALL PERSONS PERFORMING INSPECTIONS WITH SPECIAL INSPECTOR, INCLUDING LICENSE NUMBERS, COMPLYING WITH FBC CH. 110.8.6 2/1/2016 Comment: PLEASE SHOW ALL REQUIRED PROTECTION OF BUILDING ELEMENTS, COMPLYING WITH FBC CH. 6 AND TABLE 601, ASSOCIATED WITH TYPE III A CONSTRUCTION. 2/1/2016 Comment: PLEASE LOCATE ON PLANS, AND SHOW OCCUPANT LOADS, FOR CLASSROOMSNOCATIONAL ROOMS NOTED ON SHEET LS 101. 2/112016 Comment: PLEASE SHOW RATED ASSEMBLY SEPERATION AT MECHANICAL ROOM 1078. 2/112016 Comment: PLEASE NOTE AREAS 1080 AND 1085 IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE INCLUDE OCCUPANT LOADS FOR VESTIBULES, LOBBYS, ETC, IN OCCUPANCY LOAD SCHEDULE. 2/1/2016 Comment: PLEASE SHOW DETAIL OF REFERENCED MEZZANINE CEILING ASSEMBLY, NOTED ON SHEETS A403 AND A404 2l1/2016 Comment: REFERENCED SHEET A909 APPEARS TO BE MISSING. 2/112016 Comment: PLEASE INCLUDE SHOP DRAWINGS FOR SHIP LADDER TO MEZZANINE. 2/1/2016 Comment: PLEASE INCLUDE PRODUCT APPROVAL AFFIDAVIT, OR PRODUCT APPROVALS, FOR ALL COMPONENTS USED IN THE STRUCTURAL ENVELOPE OF PROJECT. 211/2016 Comment: PLEASE INCLUDE 2 SETS OF TRUSS SHOP DRAWINGS FROM TRUSS MANUFACTURER. 2/112016 Comment: PLEASE SUBMIT 2 TRUSS MANUFACTURERS LAYOUT SHEETS, REVIEWED AND APPROVED BY DESIGN PROFESSIONAL. ZONING REVIEW COMPLETE Jeffrey Johnson 121312015 12/4/2015 12/412015 Comment: