Please accept this letter and the revised sheets as my review and response to
comments. Please note that all of these same comments and responses can be found on
sheet C 1 of the permitted set.
Plans examiner review: Ed Rosebery :
PLEASE CORRECT PLANS TO SHOW PROPER OCCUPANCY CLASSIFICATION A-3, AMUSEMENT ARCADE,PER FBC
303.4
R> THE TITLE PAGE OCCUPANCY CLASSIFICATION HAS BEEN MODIFIED
PLEASE CLARIFY KITCHEN INSTALLATION IN PROJECT BLOCK, SHEETAO.I, OR REMOVE.
R> THE NOTE'KITCHEN INSTALLATION' WAS MODIFIED PREVIOUSLY AND
THE OWNER WAS GIVEN REVISED PLANS. A NEW SET WILL BE PRINTED
WITH THE REVISIONS. ALL SHEETS
PLEASE CORRECT DOOR SWING AT BATH I SO IT DOES NOT BLOCK REQUIRED EXIT ACCESS/EXIT DOOR..
R> DOOR SWING REVERSED TO CLOSE WHEN OCCUPANTS ARE TRAVELING
TOWARD THE EXIT DOOR. 3/Al
R> THE COST ASSOCIATED WITH RELOCATING THE DOOR AND THEN
RELOCATING THE FIXTURES SO THAT YOU DO NOT ENTER THE ROOM AT
THE TOILET ARE DISPROPORTIONATE TO THE LEVEL OF WORK BEING
PERFORMED.
PLEASE REMOVE ALL NOTES FROM GENERAL NOTES SHEETS THAT DO NOT PERTAIN TO THIS PROJECT.
R> GN I AND GN2 HAS BEEN REDACTED AT THE REQUEST OF THE
MUNICIPALITY REVIEWER BUT DOES NOT LIMIT THE CONTRACTOR FROM
HAVING REVIEWED THE ORIGINALLY SUBMITTED MATERIALS.
PLEASE PROVIDE. CERTIFICATION OF EXIST TWO HOUR TENANT SEPERATION WALLS.
R> HOLES WERE CUT INTO THE EXISTING WALLS AND INDEED THERE ARE
(2) LAYERS OF 5/8" TYPE X GYPSUM BOARD CONSISTENT WITH A 2HR
,LL.
22062 CONCHA AVE., BOCA RATON, FL. 33428 PH: 772.408.6963 CELL: 561.441.8126
ARCHITECTURE ROBERTS. LEWIS P.A. AR91402
jo
r�9
BUILDINGIDEAS
PLUMBING GREG SMYTH 11-12-15
PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 THIS IS NOT AN A-2 OCCUPANCY,IT IS AA-3 .PLEASE
CORRECT ON PLANS.
R> THE TITLE PAGE HAS BEEN MODIFIED AS WELL AS THE PLUMBING
CALCULATION
THIS IS A CHANGE OF OCCUPANCY TYPE.THEREFORE THIS JOB MUST MEET THE CURRENT CODE WHICH
REQUIRES HOT WATER TO THE LAVATORIES AND SERVICE SINK PER SECTION 607.1 OF THE FLORIDA PLUMBING
CODE 2014
R> A4.0 INSTA HOT WATER HEATERS HAVE BEEN ADDED TO THE PLAN
SUPPLYING EACH OF THE SINKS WITH HOT WATER
PAGE A02 REFRENCES A KITCHEN INSTALLATION PLEASE EXPLAIN AS YOU WILL NEED GREASE TRAP OUTSIDE
FOR ANY SINKS IN KITCHEN
R> THERE IS NO KITCHEN OR FOOD SERVICE ON THIS PROJECT. THE
GENERIC NOTE FOR KITCHEN SINK FIXTURE UNIT CALCULATIONS HAS
BEEN REMOVED FROM A0.2
WHEN YOU CHANGE THE SWING OF THE RESTROOM DOOR,REFRENCED BY OUR STRUCTURAL PLAN EXAMINER
KEEP IN MIND THIS DOOR CANNOT SWING INTO CLEAR FLOOR SPACE FOR ANY PLUMBING FIXTURE.PER
SECTION 603.2.3 OF THE FLORIDAACCESSABILITY CODE 2014
R> THIS WAS NOTED AND REVIEWED WITH ED ROSENBERG. THE DOOR
SWING HAS BEEN REVERSED SO THAT PANIC TRAFFIC WILL CLOSE THE
DOOR IF OPEN. THE DOOR HAS BEEN MOVED AS FAR AS POSSIBLE WITHIN
THE EXISTING WALL SO THAT IT DOES NOT OPEN ONTO THE WATER
CLOSET. THE EXPENSE OF RELOCATING THE PLUMBING FIXTURES WITHIN
THIS RESTROOM IS DISPROPORTIONATE TO THE SCOPE OF WORK FOR THIS
PROJECT.
22062 CONCHA AVE., BOCA RATON, FL. 33428 PH: 772.408.6963 CELL: 561.441.8126
ARCHITECTURE ROBERTS. LEWIS P.A. AR91402