HomeMy WebLinkAboutPRODUCT APPROVALFlorida Bui�ing code online
t
12/28/15, 11:51 AM
SCANNED ,LJI_ -��
B1
St. Lucie CountyM1 ' (I ;b
.X = s-
FA
EMS Home I lag In I User Registration Hot Topic Submit Surcharge I Slats a Facts I Publications I FBC Staff i BCIS Site Map I Links I Search
l Product Approval
it USER: Public User
EaxiUst ggtg=l Menu > Product ar Application Search > Application List > Application Detail
FL *
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL6964-R4
Revision
2014
Approved
RECEIV=D
JAN 1 1 2016
PERNUTTING
St. Lucie County, FL
DBCI
4645 Timber Ridge Rd.
Douglasville, GA 30135
(800) 542-0501 Ext 3026
braya@dbci.com
Bray Allen
braya@dbci.com
Bray Allen
4645 Timber Ridge Rd.
Douglasville, GA 30135
(770) 942-0501 Ext 3026
braya@dbci.com
Joe Hurst
DBCI
PO Box 1767
Douglasville, GA 30133
(770) 942-0501
joeh@dbci.com
Exterior Doors
Roll -Up Exterior Door Assemblies
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
John E. Scates
PE-51737
PFS Corporation
12/31/2016
Kurt Dietrich PE
Validation Checklist - Hardcopy Received
http://www.floridabuilding.org/pr/pr App otl.aspx?param=wGEVXQwtDgtShOtEf2Hnxgk6QT9FllofKx[Zfmu4dKs%3d Page 1 of 3
Florida Building Code Online
12128/15, 11:51 AM
Referenced Standard and Year (of Standard) Standard Year
ASTM E330 2002
DASMA 108 2005
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
04/30/2015
O5101/2015
05/09/2015
O6/23/2015
FL #
Model, Number or Name
Description
6964.1
Series 2500/2400
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II Series2500 B-2500-08-001 reel s.Ddf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +11.5/-13.4
Evaluation Reports
Other: Pressure varies by width from +39.6/-46.2 at 3' wide
FL6964 R4 AE Eval Rapt 2500 s.Ddf
to +11.5/-13.4 at 12' wide. See drawings.
Created by Independent Third Party: Yes
6964.2
Series 5000
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II Series5000 B-5000-08-001 revl s.Ddf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +28/-32
Evaluation Reports
Other: Pressure varies by width from +43.7/-50.0 at 10' wide
FL6964 R4 AE Eval Rent 5000 3000 s.pd
to +19.7/-22.6 at 20' wide. See drawings.
Created by Independent Third Party: Yes
6964.3
Series 650
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II Series650 B-400-005-074.02 revl s.Ddf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +13.9/-15.1
Evaluation Reports
Other: Pressure varies by width from +35.3/-38.4 at 3' wide
FL6964 R4 AE Eval Reot 650 690 s.Ddf
to +13.9/-15.1 at 8'-8" wide. See drawings.
Created by Independent Third Party: Yes
6964.4
Series 690
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II Series690 B-300-130-0001 rev4 s.Ddf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +28.2/-32.9
Evaluation Reports
Other: Pressure varies by width from +64.2/-75.0 at 4' wide
to +28.2/-32.9 at 10' wide. See drawings.
FL6964 R4 AE Eva[ Rapt 650 690 s.odf
Created by Independent Third Party: Yes
6964.5
Series K2500/K2400
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL6964 R4 II SeriesK2500 B-K2500-14-00015 Ddf
Verified By: John E. Scates P.E. FL 51737
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +11.5/-13.4
Evaluation Reports
http://www.floridabuilding.org/pr/pr_app dtl.aspx7param=WGEVXQwtDgtShGtEf2Hnxgk6QT9FllofKxiZfmu4dKs%3d Page 2 of 3
Florida Building Code Online
a 4
12128/15, 11:51 AM
Other: Pressure varies by width from +39.6/-46.2 at 3' wide
FL6954 R4 AE Eval Reot 2500 s.odf
to +11.5/-13.4 at 12' wide. See drawings
Created by Independent Third Party: Yes
6964.E
Series K3000
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II SeriesK3000 B-K3000-14-0001 s.odf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +28.0/-32.0
Evaluation Reports
Other: Pressure varies by width from +40.8/-46.7 at 8' wide
FL6964 R4 AE Eval Reot 5000 3000 s.odf
to +17.3/-19.8 at 16' wide. See drawings.
Created by Independent Third Party: Yes
6964.7
Series K5000
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 11 SeriesK5000 B-1<5000-14-0001 L2df
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +28.0/-32.0
Evaluation Reports
Other: Pressure varies by width from +43.7/-50.0 at 10' wide
FL6964 R4 AE Eval Reot 5000 3000 s.odf
to +19.7/-22.6 at 20' wide. See drawings.
Created by Independent Third Party: Yes
6964.8
Series K650
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 II Ser[esK650 B-K650-14-0001 s odf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +13.9/-15.1
Evaluation Reports
Other: Pressure varies by width from +35.3/-38.4 at 3' wide
FL6964 R4 AE Eva[ Reot 650 690 s.pd
to +13.9/-15.1 at 8'-8" wide. See drawings.
Created by Independent Third Party: Yes
6964.9
Series K690
Roll -up Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6964 R4 11 SeriesK690 B-K690-14-0001 s.odf
Verified By: John E. Scates P.E. FL 51737
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +28.2/-32.9
Evaluation Reports
Other: Pressure varies by width from +64.2/-75.0 at 4' wide
FL6964 R4 AE Eval Rept 650 690 s.odf
to +28.2/-32.9 at 10' wide. See drawings.
Created by Independent Third Party: Yes
Back FPetfl
Contact Uc :: 1940 North Mortme Street Tallahame= FL 3 399 Phone: 850-487-1824
The State of Florida is an AA/EC-0 employer. Coowiaht 2007-2013 State of Florida.:: Privaa Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public rekcrds. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S.,
please dick bvt€-
Product Approval Accepts:
® WNF M
SCCuritvatr ic.4'
http://www.floridabuilding.org/prIpr app dtl.aspx7paraM-WGEVXQwtDgtShGtEf2Hnxgk6QT9FIlofKxlZfmu4dKs%3d Page 3 of 3
Florida Building Code Online
12128115, 11:51 AM
lie"nu dfidenily ReguliiehLly.:
t, Pt°oessic�n Reulafiia
U
'' Product Approval
sfrl 01.USER: Public User
Product Menu > Product or Awlicetion Search > Application List
Search Criteria
Code Version
2014
FL#
ALL
Application Type
ALL
Product Manufacturer
DBCI
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Other
ALL
Search Results - AODHIC21 011S
Fla
Tvoe
Manufacturer
Validated By
Status
FL6964-R4
Revision
DBCI
Kurt Dietrich PE
Approved
History
Category: Exterior Doors
(704) 875-8610
Subcategory: Roll -Up Exterior Door Assemblies
-nppmvea oy warn. Hpprovais oy work snap as reweweo ano mnneo oy me rw anoror cne rnmmrsson n necessary.
....a ...,a. u... ....
The State of Florida is an AA/EEO employer. [_po vriaht 2007-2013 State of Florida" :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publio-r ds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided maybe used for official communicetion with the licensee. However email addresses are public record. If you do rot wish le supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please dick b9rg.
product Approval Accepts:
®®m m
creilitSArFE
http://www.floridabuilding.org/pr/pr..appjst.aspx Page 1 of 1