Loading...
HomeMy WebLinkAboutFIRE DISTRICT PAPPERSSAINT LUCIE COUNTY FIRE DISTRICT �i�gju!46�� PLAN REVIEW FORM 5160 N.W. Milner Drive 6L ANNED ,� '.� Port Saint Lucie, FL 34983 BY x � x.r Telephone: 772-621-3322 fit. LUCI@ CQUnq,� Fax: 772-621-3604 `3 Web Address: www.slcfd.com Building Dept. SLC FMO Permit# B-16-100 Project Name Lexington Shoppes BLDG Permit# 1601-0237 Address 6829/6831 South Federal Hwy City PSL Contractor Jhamtec Construction Inc Address 739 NW 101 Terrace City Coral Springs State FL Zip 33071 Telephone (954)445-6020 Architect/Engineer Dan Stuart Telephone (772)979-3380 Occupancy Type Assembly Construction Type A3 Square Feet 3190 Occupant Load 269 per plans Number of Stories Access Box Required Access Key Switch AFS Permit F FA Permit FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD Is required. The File format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all Inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 5. Failed Inspections require payment of fee prior to rescheduling of further Inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. 8. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC systemis that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. - See General Notes Above and Required Revisions Below 1. Panic hardware is required on all exit doors. Rear doors cannot be fixed closed unless the door is equipped with panic hardware. 2. Portable fire extinguishers from a licensed contractor is required. 3. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 4. Field inspections may require revisions. Page 1❑ of ] Reviewed by TonyJerger Date 04-18-16 ST.1LUCIIlE COUNTY FIRE IDIISTRIC �V�F cOUIUTy�ID\ FIRE PREVENTION BUREAU �; Telephone: (772) 621-3322 1 Office of the Fire Marshal i+ tJ (772) 621-3604 N t�•_ j�SANT FIRE WALLS PENETRATIONS HVAC/DAMPERS SMOKE -TEST SPRINKLERS UNDERGROUND HYDRO SPRINKLERS ABOVEGROUND HYDRO SPRINKLER FINAL FIXED FIRE SUPPRESSION SYSTEMS FIRE ALARM FINAL BUILDING FINAL MISC. INSPECTIONS "Our Family Serving }ours" 516010 W. Milner Drive, Port S4. Lucie, Florida 34983-3392 Telephone: (772) 621-3400 0 Fax:'(772) 62A-3500 W W W.s�M SAINT LUCIE COUNTY FIRE DISTRICT W= AM AM ZiliIIIII, PLAN REVIEW FORM 3 QFt S160 N.W. Milner Drive ,�; Port Saint Lucie, FL 34983 xFILt 6U13y x; Telephone: 772-621-3322 ,9E'�I,\ Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. r Project Name Address SLC FMOPermit# B-16-274rev BLDG Permit # 1601-0237 Lexington Shoppes 6829/6831 South Federal Hwy City PSL Contractor Jhamtec Construction Inc Address 739 NW 101 Terrace City Coral Springs State FL Zip 33071 Telephone (954)445-6020 Architect/Engineer Dan Stuart Telephone (772) 979-3380 Occupancy Type Assembly Construction Type A3 I Square Feet 3190 Occupant Load 269 per plans Number of Stories Access Box RegUifed Access Key Switch AFS Permit I I FA Permit I FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be.pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. �0 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. S. Failed inspections require payment of fee priorto rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. S. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 dm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. Dee uenerdi murLub muuvu drlu neq Urreu neV151un5 Deruw Page of 11-1 Reviewed by TonyJerger Date 10-31-16