HomeMy WebLinkAboutFIRE DISTRICT PAPPERSSAINT LUCIE COUNTY FIRE DISTRICT
�i�gju!46�� PLAN REVIEW FORM
5160 N.W. Milner Drive 6L ANNED
,� '.� Port Saint Lucie, FL 34983 BY
x � x.r Telephone: 772-621-3322 fit. LUCI@ CQUnq,�
Fax: 772-621-3604 `3
Web Address: www.slcfd.com
Building Dept. SLC FMO Permit# B-16-100
Project Name Lexington Shoppes BLDG Permit# 1601-0237
Address 6829/6831 South Federal Hwy City PSL
Contractor Jhamtec Construction Inc
Address 739 NW 101 Terrace City Coral Springs
State FL Zip 33071 Telephone (954)445-6020
Architect/Engineer Dan Stuart Telephone (772)979-3380
Occupancy Type Assembly Construction Type A3 Square Feet 3190
Occupant Load 269 per plans Number of Stories Access Box Required Access Key Switch
AFS Permit F
FA Permit FFP Permit
General Notes
1. An electronic copy of the construction documents submitted on a CD Is required. The File format shall be .pdf only.
2. All revisions, including the electronic copy must be received prior to permitting.
3. The Fire Marshal requires 24 hour notice on all Inspections.
4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
5. Failed Inspections require payment of fee prior to rescheduling of further Inspections.
6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans.
7. Fire alarm panels shall be located indoors within air conditioned space.
8. Plans and construction are subject to corrections in the field to maintain code compliance.
9. Automatic fan shutdown is required for HVAC systemis that exceed 2,000 cfm design capacity.
10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit.
THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY. -
See General Notes Above and Required Revisions Below
1. Panic hardware is required on all exit doors. Rear doors cannot be fixed closed unless the door is equipped with panic hardware.
2. Portable fire extinguishers from a licensed contractor is required.
3. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity.
4. Field inspections may require revisions.
Page 1❑ of ] Reviewed by TonyJerger Date 04-18-16
ST.1LUCIIlE COUNTY FIRE IDIISTRIC �V�F cOUIUTy�ID\
FIRE PREVENTION BUREAU �; Telephone: (772) 621-3322
1
Office of the Fire Marshal i+ tJ (772) 621-3604
N t�•_ j�SANT
FIRE WALLS
PENETRATIONS
HVAC/DAMPERS SMOKE -TEST SPRINKLERS UNDERGROUND HYDRO
SPRINKLERS ABOVEGROUND HYDRO
SPRINKLER FINAL
FIXED FIRE SUPPRESSION SYSTEMS
FIRE ALARM FINAL
BUILDING FINAL MISC. INSPECTIONS
"Our Family Serving }ours"
516010 W. Milner Drive, Port S4. Lucie, Florida 34983-3392
Telephone: (772) 621-3400 0 Fax:'(772) 62A-3500
W W W.s�M
SAINT LUCIE COUNTY FIRE DISTRICT W= AM AM ZiliIIIII,
PLAN REVIEW FORM
3 QFt S160 N.W. Milner Drive
,�; Port Saint Lucie, FL 34983
xFILt 6U13y
x; Telephone: 772-621-3322
,9E'�I,\ Fax: 772-621-3604
Web Address: www.slcfd.com
Building Dept.
r Project Name
Address
SLC
FMOPermit# B-16-274rev
BLDG Permit # 1601-0237
Lexington Shoppes
6829/6831 South Federal Hwy
City
PSL
Contractor Jhamtec Construction Inc
Address 739 NW 101 Terrace City Coral Springs
State FL Zip 33071 Telephone (954)445-6020
Architect/Engineer Dan Stuart Telephone (772) 979-3380
Occupancy Type Assembly Construction Type A3 I Square Feet 3190
Occupant Load 269 per plans Number of Stories Access Box RegUifed Access Key Switch
AFS Permit I I FA Permit I FFP Permit
General Notes
1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be.pdf only.
2. All revisions, including the electronic copy must be received prior to permitting.
�0 3. The Fire Marshal requires 24 hour notice on all inspections.
4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
S. Failed inspections require payment of fee priorto rescheduling of further inspections.
6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans.
7. Fire alarm panels shall be located indoors within air conditioned space.
S. Plans and construction are subject to corrections in the field to maintain code compliance.
9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 dm design capacity.
10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit.
THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
Dee uenerdi murLub muuvu drlu neq Urreu neV151un5 Deruw
Page of 11-1 Reviewed by TonyJerger Date 10-31-16