Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONReviewed ® Furnish as Corrected Rgiented Revise and Resubmit Accop-t,>•' ( Submit Speciffed Item ltus rav t Is dnt•, Eca• >^<;:l Cor!faml,nca with the design concept ondtho 'ift%nation given in fhe Documents. Corrections or comments anode on the shop drawings during this review do not relieve the centractor horn compliance with the requirements of the plants and spgcitications. yapmval of a specific item shah not include apprt val of an assembly of which 11* item is a component. The contractor Is responsible for; dimensions to be Mfirmed and correlated at the jobsite, irformation that psrtalns solelyto the dbtication of censbaction; L'te eoordirargn of the Work with that of all other rades ; and performing a;I Work in a safe and satisfactory manner. VRA DESIGN, INC. WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. WP 1200 GENERIC GYPSUM WALLBOARD, STEEL STUDS One layer 5/8" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 3 5/8" steel studs 24" o.c. with 1" Type S drywall screws 8" o.c. at vertical joints and 12" o.c. at Floor and ceiling runners and intermediate studs. Joints staggered 24" on opposite sides. (NL136GANNED BY St. Lucie Countv 1 HOUR 40 to 44 STC FIRE I I SOUND Thickness: 4 7/8" Limiting Height: Refer to Section IV Approx. Weight: 6 psf Fire Test: FM WP-45, 6-19-68; OSU T-1770, 8-61; ULC 79T484, 79T500, 79T497, 8-12-81, ULC Design W415 Sound Test: NGC 2385, 7-28-70