HomeMy WebLinkAboutPROJECT INFORMATIONReviewed ® Furnish as Corrected
Rgiented Revise and Resubmit
Accop-t,>•' ( Submit Speciffed Item
ltus rav t Is dnt•, Eca• >^<;:l Cor!faml,nca with the design concept ondtho
'ift%nation given in fhe Documents. Corrections or comments
anode on the shop drawings during this review do not relieve the centractor
horn compliance with the requirements of the plants and spgcitications.
yapmval of a specific item shah not include apprt val of an assembly of which
11* item is a component. The contractor Is responsible for; dimensions to be
Mfirmed and correlated at the jobsite, irformation that psrtalns solelyto the
dbtication of censbaction; L'te eoordirargn of the Work with that of all other
rades ; and performing a;I Work in a safe and satisfactory manner.
VRA DESIGN, INC.
WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE
GA FILE NO. WP 1200
GENERIC
GYPSUM WALLBOARD, STEEL STUDS
One layer 5/8" type X gypsum wallboard or gypsum veneer base applied parallel or at
right angles to each side of 3 5/8" steel studs 24" o.c. with 1" Type S drywall screws 8"
o.c. at vertical joints and 12" o.c. at Floor and ceiling runners and intermediate studs.
Joints staggered 24" on opposite sides. (NL136GANNED
BY
St. Lucie Countv
1 HOUR 40 to 44 STC
FIRE I I SOUND
Thickness:
4 7/8"
Limiting Height:
Refer to Section IV
Approx. Weight:
6 psf
Fire Test:
FM WP-45, 6-19-68;
OSU T-1770, 8-61;
ULC 79T484, 79T500,
79T497, 8-12-81,
ULC Design W415
Sound Test:
NGC 2385, 7-28-70