HomeMy WebLinkAboutWELDER QUALIFICATION TEST RECORD*000000
Cj .3 C'O"OPY
Welders Name Noe Huerta Dale . 05 / 03 / 16
Welding Procedure Specification No. P7
-001- Social Security Number xxx-xx-7985
SCANNED Actual Values Used in Qualification Range
Process/Type [Table 4.12, Item (1)] BY SMAW Qualification SMAW
Current/Polarity St. Lucie CoUr&ElecUode+ All
Position [Table 4.12, Item (3)]
Weld Progression [Table 4.12, Item (5)]
Backing (Yes or No) [Table 4.12, Item (6)]
Material / Spec
Base Metal [Table 4.12, Item (4)]
Thickness (Plate)
Groove
Fillet (ram Q fE 0
Thickness (PipeI
L� �''�l�
Groovee
Fillet SEP - 2 K7-
Diameter (Pipe)
Filler Metal (Table 4.12, Item 12
Spec No. A5.1
Class
F-No. F nn
YIIS-1i�t7791Ifii:�
.125 - -750 CJP Groove welds
All F #s [ Table 4.12-4.13 ]
Visual Weld Appearance: (Clause 4.9)
Guided Bend Test: (Clause 4.31.5)
1. ®Pass OFail 3G
Type Position
Result
Face 3G
Root 3G
Pass
Pass
2. ®Pass OFail 4G
Macroetch Test Results: (Subclause 6.3.7.3)
1. OPass OFail
Face 413
Pass
2. OPass OFail
Root 4G
Pass
Fillet Weitl Test: (Subclause 6.3.7.4)
Inspected by Walter W. Posten Jr. CWI# 1508075
1.0 Pass OFail
Test No. 0002
Date 04/30/16
2.13 Pass OFail
RADIOGRAPHIC TEST RESULTS
Film Identification
Results
Remarks Film Identification
Results
Remarks
Interpreted By Test No.
Organization Date
We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and
tested in accordance with the requirements of AWS D1.1:2010, Structural Welding Code —Steel.
QUALIFICATION RESULTS
The Welder/Operator identified above ®DOES 0 DOES NOT meet the performance qualifications specrfied in the
AWS DI A: 2010 code for the variables stated.
Date tested 04/30/16
Tested by: Precision Weld Technologies
13501 Okeechobee Rd
Fort Pierce, FL 34945
772-462-7742
Signed By:yL� 4�9 .
Waiter W. Posten Jr. CWI# 15080751
Stamp:
Won pasba.9r
CAM 15=731
QC1 EXP.6/1/2818