HomeMy WebLinkAboutENERGY CONSERVATION PAPPERSCheck List SCANNED St. Lucie County Applications for compliance with the Florida Building Code, Energy Conservation shall Inc de: 57 This Checklist An Input report generated from the software just after completing compliance calculations without any further changes The full compliance report generated by the software that contains the project summary, complaince summary, certifications and detailed component compliance reports Boxes appropriately checked in the Miscellanous report generated by the software at the end of the compliance report 7-0r-� OF ADVANCED y� ARCHITECTURE. PLANNING LLC ; AA-26002573 r D 3 - II-Gh EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 1 of 12 PROJECT SUMMARY ShortDese: GARDENS PLAZA#3 Owner Addressl: Address2: Description: GRDENS PLAZA SUITS City: State: Zip: Type: Retail Class: Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Conditioned Area: 1165 SF Conditioned & UnConditioned Area: No of Stories: 1 Area entered from Plans Permit No: 0 Maz Tonnage If different, write in: Component LIGHTING CONTROLS EXTERNAL LIGHTINNG HYAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PORT ST. LUCIE FL 0 New Finished building 1165 SF 0 SF 0 Design Criteria Result 1,002.0 1,367.0 PASSED PASSES PASSES PASSES No Entry PASSES No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 — — — An input report of this design building must be submitted along with this EnergyGauge Summit® F181Com-2014. TAM 2014-1.0 Comp[iant Software. Effective Date: June 30, 2015 3/14/2016 Page 2 of 12 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: ' 1 ` f� Official: Date: �i �L�--gin Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Ling Designer: Reg No: MecliamcalDesigner: Reg No: CA�B�tQ1i Plumbing Designer: Reg No: () Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 3 of 12 Project: GARDENS PLAZA#3 Title: G"FNS PLAZA sum #3 Type: Retail Total Uses 1) Proposed 2) Baseline 65.10 105.20 $1,002 $1,608 ELECTRICITY(MBtu/kWh 65.10 105.20 19084 30812 $1,002 $1,608 AREA LIGHTS 6.90 34.40 2026 10071 $106 $526 MISC EQUIPMT 17.10 17.10 4998 4998 $262 $261 PUMPS & MISC 0.00 0-00 8 6 $0 $0 SPACE COOL 22.50 28.30 6597 8296 $346 $433 SPACE HEAT 0.20 0.40 72 IM7 $4 $7 VENT FANS 18.40 5383 $283 Applied: None Criteria =1367 (including any credits) =1002 requires Proposed Building cost to be at most 85% of e cost. This Proposed Building is at 62.3% 25.00 7314 $382 PASSES EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date. June 30, 2015 3/14/20I6 Page 4 of 12 Project: GARDENS PLAZA #3 Title: GRDENS PLAZA SUITE #3 Type: Retail (WEA101e: DAYTONABEACH TMY) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or 8) ENt Light 1 Main entries Yes 30.00 20.0 600 20 Tradable Surfaces: 20 (W) Allowance for Tradable:1350 (W) PASSES All External Lighting: 20 (W) Complicance check includes a excess/Base allowance of 750.00(W) Project: GARDENS PLAZA#3 Title: GRDENS PLAZA SUM #3 Type: Retail (WEA File: DAYTONABEAC$TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Mn Compli- ID (sgft) CP CP ance Pt0Zo1Sp1 25,001 Sales Area 1,165 1 1 PASSES PASSES Project: GARDENS PLAZA#3 Title: GRDENS PLAZA su #3 Type: Retail (WEAFile: DAYTONABEACH.TMY) System Report Compliance ProSyl System 1 Constant Volmne Air Cooled No. of Units Split System < 65000 Bta/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Conditioners Air Cooled 36 14.00 12.23 8.00 PASSES Split System < 65000 BbA Cooling Capacity Heatmg System Electric Furnace 27000 1.00 1.00 PASSES Air Handling System Air Handler (Supply) - 1200 0.80 0.82 PASSES -Supply Constant Volume i PASSES EnergyGauge Summit® Fla/Com 2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 5 of 12 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: GARDENS PLAZA#3 Title: GRDENS PLAZA SDTTE #3 Type: Retafl (WEAFile- DAYTONABEACH.TMY) Water Heater Compliance Description Type Category Design Min Design Man Comp Eff Eff Loss Loss liance Water Heater 3 Electric water heater 412 [kW] 0.95 0.90 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance ['aches] Runout? Temp [Btu-bOw Thick [a] Thick [in] [F] .SF3] None EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 6 of 12 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Section Yes N/A Ex barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an Air Leakage CA024.3,C4024.4 Envelope approved manner. Factory -built fenestration and doors are labeled as 13613 meeting air leakage requirements. Air Leakage C402 4-7 Envelope Vestibules are installed on all butdng entrances. 0 [a ❑ Doors have self -closing devices. Air Leakage C402.4.1.1 Envelope All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped With moisture vapor -permeable wrapping material to minimize air Air Leakage C402.4.6 Envelope leakage. Weetherseals Installed on at loading dock cargo doors Air Leakage C402.4.8 Envelope Recessed luminaires in thermal envelope to limit E3 0 Infiltration and be IC rated and labeled. Seal Fenestration C303.1.3 Envelope between irderior finish and luminaire housing. Fenestration products rated in accordance with NFRC.El Fenestration 0303.1.3 Envelope Fenestration products are certified as to performance labels or certificates provided. Fenestration C402.2.7 Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. Insulation C3032 Envelope Below -grade wall insulation installed per manufacturers Instructions. Insulation C303.2 Envelope Slab edge insulation installed per manufacturers Instructions. Insulation C4022.6 Envelope Slab edge insuation depthfiength. Slab Insulation 13 ff E3 extending away from bulldog Is covered by Insulation 04032.7,040828,C Envelope pavement or>=10Inches ofsou7. Exterior insulation protected against damage, 0El sunlight moisture, wind, landscaping and Insulation C402.42.1 Envelope equipment maintennance activities. Roof R-value. Forsome ceiling systems, 00" verification may need to occur during Framing Inspection. Insulation C3032 Envelope Roof Insulation Installed per manufacturers 11 Instructions. Blown or poured loose -fill insulation is Insulation C4022.1 Envelope Installed onlywhere the roofslope is e=3 to 12. Skylight curbs are insulated to the level of roofs 11 �j '171 with insulation above deck or R.S. Insulation C:4022.1.1 Envelope High-albedo roofs satisfy one of the following: !� 3-yearaged solar reflectance >= 0.55 and thermal emitance r- 0.75. 3-year--aged solar reflectance Index — 64.0, initial year solar reflectance � 0.70 Insulation C3032 Envelope and thermal emitartce r- 0.75, or initial year solar Above -grade wall Insulation installed per 00 0 manufacturers instructions. Insulation C3032 Envelope Floor insulation installed per manufacturers ©` instructions. Insulation C303.1 Envelope Building envelope Insulation is labeled with R-value 13 Ia El or insulation certificate providing R-value and other Insulation C3032.1 Envelope relevant data. Fxtedor insulation is protected from damage with a If El Protective material. Verification for exposed foundation Insulation may need to occur during Foundation Inspection r.nergy'�auge aummman rlarcom=21114. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 7 of 12 Insulation 04022.1 Envelope Insulation Intended tomeettheroof Insulation ❑ ❑ ❑ requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant Controls C405.2.4 Exterior Lighting Automatic lighting if insulation Is Icontmled �fo exxtteerior lighting ❑ � ❑ installed. Wattage C405.6 Exterior Lighting Exterior grounds lighting over 100 W provides ❑ �j ❑ ImM! unless on motion sensor or fbdure is exempt Wattage 0405.6.2 Exterior lighting from scope of code orfrom external LPD. Exterior righting power is consistent with what is ❑ d ❑ shown on the approved Fighting plans, - demonstrating proposed watts are less than or Controls C40522.1 Interior Lighting owed watts. Automatic g al to controshut off all bulding righting ❑ Ej ❑ Installed in all buildings. Controls 04052.1.1 Interior Lighting Independent lighting controls Installed per approved ❑ /� ❑ lighting plans and all manual controls readily Controls 04052.12 Interior Lighting accessible and ible to occupants. Lighting controls install d to uniformly reduce the ❑ 1:1 ❑ fighting load by at least 50%. Controls C40522.3 Interior Lighting Daylight zones provided with Individual controls that ❑ ❑j ❑ control the lights Independent of general area Controls 04052.3 Interior Lighting lighting. Sleeping units have at least one master switch at El ❑' the main entry door that controls wired luminaires Conrols 0405222 Interior Lighting and Occupancy switched essensors installed in required spaces. Controls C40522.3 Interior Lighting Primary siderigtded areas are equipped with ❑ ❑ required righting controls. Controls C40522.3 Interior Lighting Enclosed spaces with daylight area under skylights ❑ ❑ and rooftop monitors are equipped with required Controls C4052.3 Interior Lighting lighting controls. Separate Fighting control devices for specific uses ❑ installed per approved lighting plans. Controls C405.3 Interior Lighting Fluorescent luminaires within odd numbered lamp ❑ 7� ❑ configurations that are with 10 feet center to center (if recess mounded) or are within 1 foot edge to edge (if pendant or surface mounted) shall be Watage C405.4 Interior Lighting tandem wired. Fait signs do not exceed 5 watts per face. ❑ [2 ❑ Wattage C4052.3 Interior Lighting Additional Interior fighting power allowed for special ❑ — functions per the approved lighting plans and is automatically controlled and separated from Wattage C405.52 Interior Lighting general lighting. Interior installed lamp and fodure lighting power is ❑ 130 ❑ consistentwlh what is shown on the approved Fighting plans, demonstrating proposed watts are HVAC C4032.4.5 Mechanical less than or equal to allowed watts. Freeze protection and snowfice melting system ❑ ❑ sensors for future connection to controls. HVAC C4032.3 Mechanical HVAC equipment efficiency verified. ❑ ❑— ❑ Air Leakage C402.4.5.1 Envelope Stair and elevatorshattvems have motorized ❑ ❑ dampers that automatically dose. Air Leakage 0402.4.52 Envelope Outdoor air and exhaust systems have motorized ❑ E ❑ dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity HVAC C4032.5.1 Mechanical dampers where allowed. Demand control ventilation provided for spaces ❑ Ef ❑ >500 V2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or HVAC 04032.8.1 Mechanical design axflow>3,000 cim. Piping Insulation exposed to weather is protected ❑ ❑ from damage (due to sun, moisture, wind, etc.). EnergyGauge Summit® Fle/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 8 of 12 HVAC C403.2.7 Mechanical HVAC ducts and plenums Insulated. Where ducts 0 [a 0 or plenums are Installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC 0403.2.8 Mechanical Thermally ineffective panel surfaces of sensible Inheating 13 panels have insulation>= R3.5. HVAC C4032.7 Mechanical Duals and plenums sealed based on static pressure and location. HVAC C40822.1 Mechanical Air outlets and zone terminal devices have means 0El El for air balancing. HVAC C4032.6 Mechanical Exhaust air energy recovery on systems meeting [aTable El C4032.6 HVAC C4032.11 Mechanical Unencimed spaces that are heated use only 11 El radiant heal HVAC C4032.4.1 Mechanical Heating and cooling to each zone is controlled by a L"J thermostat control. HVAC 04032.42 Mechanical Thermostatic controls have a 5 °F deadband. 0' HVAC C403.242 Mechanical Temperature controls have setpoint overlap restrictions. HVAC C4032.4.3 Mechanical Each zone equipped with setback controls using ElEj El automatic time clock or programmable control HVAC C40324.3 Mechanical system. Automatic Controls: Setback to 65°F (heat) and 85°F (coot); 7-day clock, 2-hour occupant override, SYSTEM SPECIFIC C404.3 Mechanical 10-hour backup Temperature controls installed on service water El El heating systems (110 OF for dwelling units and lavatories in public restreoms and 90 °F for other SYSTEM SPECIFIC 0404.4 Mechanical occupancies.) Automatic time switches installed to automatically switch off the recirculating hot-water system or heat SYSTEM SPECIFIC C4042 Mechanical Heattraps installed on non -circulating storage 13 water tanks. SYSTEM SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 In. by 42 in. 13 �i 13 labeled for replacement only as per Footnote b to SYSTEM —SPECIFIC C4o3,42 Mechanical Table C403.2.3(3), VAV fan >= 7.5 hp are driven by mechanical or 0 electrical variable speed drive, or driven by vane-aXial with variable speed blades, or operate with motor demand G30% design kW at 50% SYSTEM SPECIFIC C4032.8 Mechanical design low -oalcWations required HVAC piping insulation thickness. Where piping is El 13 El u Installed in or under a slab, verification may need to SYSTEM SPECIFIC C4032,7.1.3 Mechanical occur during Foundation Inspection. Ductwork operating>3 in. water column requires �� air leakage testing. SYSTEM —SPECIFIC 0403.3.1,C403.3,1.1 Mechanical Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-GmRshut-off, Integrated economizer control, and provide a means to refleve SYSTEM —SPECIFIC C403.3.1,C403.4.1 Mechanical excess outside air during operation. Water economizers provided where required, meet the requirements for design capacity, maximum SYSTEM —SPECIFIC C403AAA Mechanical pressure drop and integrated economizer control. Economizer operation Will not increase heating �- El energy use during normal operation. SYSTEM SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and cooling and sequence heating and cooling to each SYSTEM SPECIFlC C403.4,3.1 Mechanical zone. Three -pipe hydronic systems using a common d 13 return for hot and chilled water are not used. EnergyGauge Summit® FlafCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2o16 Page 9 of 12 SYSTEM SPECIFIC 0403.4.32 Mechanical Two -pipe hydronic systems using a common ❑ distribution system have controls to allow a deadband r_15 OF, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to Omit heating and cooling supply temperature to <=30 OF. SYSTEM -SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to a ❑ m ❑ common water loop meet heat rejection and heat add'fion requ-vements. SYSTEM SPECIFIC C408222 Mechanical HVAC hydronic heating and cooling colls have ❑ nj' ❑ means to balance and have pressure test TY' connections. SYSTEM SPECIFIC C403.2.10.1 Mechanical HVAC fan systems at design conditions do not ❑ ❑ exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM SPECIFIC C4032.102 Mechanical M/AC fan motors not larger than allowable limits. ❑ ❑ SYSTEM,SPECIFIC C403.42 Mechanical VAV fan motors >=-7,5 hp to be driven by variable ❑ ff ❑ speed drive, have a vane aDdal fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM_SPECIFIC C403A2.1 Mechanical VAV fans have static pressure sensors positioned ❑ E/ ❑ so setpoint r_1/3 total design pressure. SYSTEM -SPECIFIC 0403.42.2 Mechanical Reset static pressure setpolat for DDC controlled ❑ f7 ❑ VAV boxes reporting to central controller based on the most pressure. SYSTEM -SPECIFIC C403.4.5.4 Mechanical Mezoneultiple zoonene HVAVAC systems have supply air ❑ d ❑ temperature reset controls. SYSTEM SPECIFIC 0403.4.3.4 Mechanical Hydronic systems greaterthan 300,000 Btuflr ❑ [5 ❑ designed for variable fluid flow. SYSTEM -SPECIFIC C403.4.3.5 Mechanical Reduce flow In pumping systems >10 hp to multiple ❑ ❑ chillers or boi erswhen others are shut down. ;a SYSTEM SPECIFIC C403.4.3.4 Mechanical Temperature reset by representative building loads ❑ ❑j ❑ In pumping systems for duller and boller systems >300,000 Stu/h. SYSTEM -SPECIFIC C403.4.3.3.3 Mechanical Two -position automatic valve Interlocked to shut off ❑ d ❑ water flow when hydronic heat pump with pumping Pa hp is off. SYSTEM -SPECIFIC C403.4.4 Mechanical systems ss with mntorsr-7,5 hp associated with ❑ ❑ heat rejection equpmentto have capability to operate at 213 of full -speed and auto speed controls to control the leaving fluld temperature or condensing temp/pressure of heat rejection device. SYSTEM -SPECIFIC C403.4.6 Mechanical Condenser heat recovery system that can heat ❑ d ❑ water to 85 OF or provide 60% of peak heat rejection is installed for preheating of service hot water in 2417 facility, water cooled systems reject >6 MMBtu, SHW load>=1 MMBhr. r SYSTEM_SPECIFIC C403.4.7 Mechanical Hot gas bypass limited to: r--240 kBbA-50% >240 kStulh-25% SYSTEM -SPECIFIC 04042 Mechanical Service water heating equipment meets efficiency ❑ ❑ requirements. SYSTEM -SPECIFIC C4032.42 Mechanical Healing and cooling to each zone Is cordrofied by a ❑ ❑' ❑ thermostat control. Minimum one humidity control device per installed humldificallon/dehumidification system.❑ SPECIFIC C4032.4.3.3 Mechanical Systems include optimustart controls. �{ LJ ElSYSTEM SYSTEM SPECIFIC 04032.4.1.1 Mechanical Heat pump controls prevent supplemental electric ❑ ❑' ❑ resistance heat from coming on when not needed. SYSTEM -SPECIFIC C404.3 Mechanical Public lavatory faucet water temperature —110"F. ❑ ❑a ❑ SYSTEM SPECIFIC C404.5 Mechanical An piping in c'acularmg system insulated ❑ ❑' ❑ SYSTEM -SPECIFIC 0404.5 Mechanical First 8 ft of outlet piping Is insulated ❑ ❑ ❑ EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 10 of 12 C404.5 SYSTEM —SPECIFIC ' C404.6 SYSTEM SPECIFIC C404.7.1 SYSTEM SPECIFIC C40433 SYSTEM SPECIFIC C404.72 SYSTEM —SPECIFIC 04032.3 Testing C408232 MandatoryAdditonall C406 Insulation C4022.8 or extemally heated piping insulated Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank Mechanical Pool heaters are equipped with onfoff switch and no continuously burning pilot fight Mechanical vapor retardant pool covers are provided for heated pools and permanently installed spas. Mechanical Time switches are installed on at pool heaters and PUMPS. Mechanical Centrifugal fan open-ckcuut cooling towers having combined rated capacity >= 1100 gpm meets minimum efficiency requirement x382 gpm/hp. Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Project Efficient HUAC performance, efficient Gghling system, or on -site supply of renewable energy consistent wth what is shown the approved plans. Project Bottom surface of floor sfirclures incorporating radiant heating Insulated to>=R3.5. ■ I ■ ■ G ■ ■ 0 ■ ❑ 0 ❑ ❑ a❑ ❑ M ❑ ❑ 0-❑ ❑ ff❑ with which compliance can be determined forthe building envelope and document where exceptions to the standard are darned. Plan Review C1032 Exterior Ughting Plans, specifications, and/or calculations provide all ❑ ❑ ❑ Information with which compliance can be determined for the exterior lighting and electrical systems and equipment and documentwhere exceptions to the standard are claimed. information Plan Review C1032 Interior Lighting provided shoul Plans, specifications, and/or calculations provide all ❑ ❑ ❑ Information with which compliance can be determined forthe interior lighting and electrical systems and equipment and document where exosptionsto the standard are clammed. Information Plan Review C1032 Mechanical provided shoul Plans, spedficatiors, and/or calculations provide all ❑ ❑ ❑ Information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per Plan Review 01032 Mechanical acceptable engineering st Plans, specifications, and/or calculators provide all ❑ ❑ ❑ Information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are clammed. Hot water system s¢ed Plan Review 0406 Project per manufact Plans, spadfications, andfor calculations provide all ❑ ❑ ❑ Information with which compliance can be detertnmed forthe additional energy efficiency Plan Review C402.322 Envelope package sopt Skylights In office, storage, automotive service, El ❑ ❑ manufacturing, non -refrigerated warehouse, retail store, and dfsfributionfsorting area have a measured haze value > 90 percent unless designed to exclude directsunlight. Post Construction C408.3 Exterior Lighting Ughting systems have been tested to ensure U V U proper calibration, adjustment, programming, and operation. C4082.5.1 Interior Lighting Furnished as -built drawings for electric power 0011 systems wifhin 30 days of system acceptance. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date. June 30, 2015 3/14/2016 Page 11 of 12 Post Construction C303.3,04082.5.2 Interior Lighting Furnished O&M Instructions for systems and equipment to the building owner or designated representative. Post Construction C408.3 Intedor Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Post Construction C4082.5.1 Mechanical Furnished HVAC as-bullt drawings submitted within ❑ El 90 days of system acceptance. Post Construction C303.3,C4082.52 Mechanical Furnished O&M manuals for HVAC systems within 0 ❑ 90 days of system acceptance. Post Cohsbuctlon C4082-5.3 Mechanical An air andfor hydronic system balancing report is provided for HVAC systems. Post Construction 04082.1 Mechanical Commissioning plan developed by registered El El ❑ design professional or approved agency. Post Construction C4082.4 Mechanical Preliminary commissioning report completed and certified by registered design professional or approved agency. Post Construction C4082.5A Mechanical Final commissioning report due to building owner 0 within 90 days of receipt of cerlificate of occupancy. Post Construction C4082.3.1 Mechanical WAG equipment has been tested to ensure proper operation. Post Construction C4082.3.3 Mechanical Economizers have been tested to ensure proper ❑ ❑ operation. - EnergyGauge Sumrr M Fla1Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/14/2016 Page 12 of 12 Right -Suite@ Universal 2015 Short Form Job: - W rightsoft® Date: Jan 12, 2016 Entire Building By: QUICK CALCS, INC. 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone; 772-466-6799 Fax. 772-466-6796 Emil: QUICKCALCS@,AOL.COM For. GARDEN PALZA SUITE#3, PORT ST. LUCIE, FL Htg CIg Htg CIg Outside db (°F) 42 84 Inside db (°F) 70 75 Outside RH N - 71 Inside RH (%) - 50 Outsidewb (OF) - 77 Insidewb (°F) - 63 Daily range (OF) - 15 Design TD (°F) 28 9 Moisture dill. (gr/lb) - 61 Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan Elec strip 100 EFF 10.0 kW 34.1 MBtuh 4.5 gpd 95.7 OF 1207 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Cooling Equipment Make Trane Model 4TTR3036E1/TEM3AOC42S4 Type Split AC COP / EER / SEER 14.0 Sensible Cooling 25.3 MBtuh Latent Cooling 10.9 MBtuh Total Cooling 36.2 MBtuh Leaving Air Temp 55.0 OF Actual Cooling Fan 1207 cfm Entire Building PEAKCV PACKAGE 0 % 0 in H2O NAME Area ft2 Heat Loss Sensible Gain Latent Gain Htg cfm Clg cfm Time SUITE #3 1165 20470 24547 11904 1207 1207 Jul 1200 LDT Entire Building 1165 20470 24547 11904 1207 1207 Jul 1200 LDT WCI I7tSOfC° 2016-Feb10:08:04 9 RlghtSulteGil Unlveml 201515.0.19 RSU08101 Page 1 C:1Usem%Quick CalmIDmc ras\GARDEN PLAZA.rup Calc =CLTD Front Door faces: N wrightSoftRight-Suite® Universal 2016 Load Summary Job: Date: Jan 12, 2016 SUITE 93 By: QUICK CALCS, INC. 317 ST.. LUCIE LN., Fr.. PIERCE, FL 34M Phone: 772-466-6799 Fu: 772-466-6796 Emil: QUICKCALCS@AOLCOM For. GARDEN PALZA SUITE#3, PORT ST. LUCIE, FL ,'Zone:' _SUITE_#3 .-`_.COOLING.LOAD-... 1. DESIGN CONDITIONS at Jul 1200 LOT Peak load at Jul 1200 LDT Inside: 75 OF Outside: 84 OF TD: 9 OF RH: 71 % MoistDiff: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 10206 3. TRANSMISSION GAINS Sensible 2257 Walls: 892 - - Glass: 1120 - - Doors: 52 - - Partitions: 0 - - Floors: 0 - - Ceilings: 193 - - 4. INTERNAL HEAT GAIN Sensible Latent 6338 2200 Occupants: 2750 2200 - - Lights: 3588 - Motors: 0 - Appliances: 0 0 - - 5. INFILTRATION- Outside air cfm: 10 101 418 6. SUBTOTAL: Space load Sensible Latent 18902 2618 Envelope 18902 2618 - - Less wdemal 0 - Redistribution 0 0 - 7. SUPPLYDUCT 2096 8. SUBTOTAL: Space load + supply duct 20999 Actual cfm: 1207 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 9" 2235 9286 10. RETURNAIRLOAD: Lighting + plenum (net) 0 - 11. RETURNDUCT 1313 - 12. TOTAL LOADS ON EQUIPMENT 24547 11904 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 7905 Walls: 2317 - Glass: 4181 - Doors: 194 - Partitions: 0 - Floors: 1109 - Ceilings: 105 - 15. INFILTRATION: Outside air cfm: 79 2444 16. SUBTOTAL: Spaceload 10349 Envelope 10349 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 1315 18. VENTILATION: Make-up air cfm: 222 6841 19. HUMIDIFICATION 1638 Piping 0 20. RETURN DUCT 327 21. TOTAL HEATING LOAD ON EQUIPMENT 20470 wrightsoft, 2016-Feb-24 10:08:04 RlghtSuite® Universal 2015 15.0.19 RSU W101 Page 1 C:\Users:\Quick Cales\Doc"rds\GARDENPLAZA.rup CaIc=CLTD FruMDoorfaees: N Project Name: GARDENS PLAZA #3 Project Title: GRDENS PLAZA SUITE 93 Address: State: FL Zip: 0 Owner: EnergyGauge Summit® v5.10 Pro*ect Information Orientation: North Building Type: Retail Building Classification: New Finished building No.ofStories: ] GrossArea: 1165 SF Zones No Acronym Description Type Area [st] Multiplier Total Area [sf] 1 PrOZol Zone 1 CONDITIONED 1165.2 1 1165.2 ❑ Spaces No Acronym Description Type Depth IN Width Height Multi IN [ft] plier Total Area [sf] Total Volume [cf] 3/14/2016 EnergyGauge Summit® v5.10 1 In Zone: PrOZol I Pr0ZolSvl ZOOSpl Sales Area 35.31 33.00 10.20 1 1165.2 11885.4 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 15 25 375 Manual On/Off 1 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value' [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sEF/Btu] [Btu/sEF] In Zone: Pr0Zo1 1 PrOZolWal Stucco, 8" Block, 33.00 10.20 1 336.6 West 0.1110 7.751 41.32 9.0 ❑ R-4.1, 1/2" Gyp. Brd. 2 PrOZOlWa2 Stucco, 8" Block, 33.00 10.20 1 336.6 East 0.1110 7.751 41.32 9.0 ❑ R-4.1, 1/2" Gyp, Brd. Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: PrOZol In Wall: EAST 1 PrOZol Wa2Wil User Defined No 0.9000 0.50 0.40 3.00 7.00 6 126.0 ❑ 3/14/2016 EnergyGauge Summit® v5.10 2 Doors No Description Type Shaded? Width H (Effec) Multi IN [ft] plier Area [sf] Cond. Dens. Heat Cap. [Btu/hr. sf F] Vb/cf] [Btu/sf F] R-Value [b.sf.FBtu] In Zone: PrOZol In Wall: WEST 1 PrOZOlWalDrl Solid core flush (2.25) No 3.00 8,00 1 24.0 0.3504 0.00 0.00 2.85 ❑ Roofs No Description Type Width H (Effec) Multi Area [ft] IN plier [sf] Tilt [deg] Cond. Heat Cap Dens. [Btu/hr. SE F] [Btu/sf. F] Rb/cf] R-Value [h.sf.F/Btu] In Zone: PrOZol 1 PrOZolRfl Mtl Deck, Bar joist, R 19 rigid insulation 30.86 34.00 1 1049.2 0.00 0.0525 0.94 5.30 19.1 ❑ Skylights No Description Type U SHGC Vis.Trans [Btu/hr sf F] W [ft] H (Effec) Multiplier Area [R] [Sfl Total Area M In Z!tof:— Floors No Description Type Width H (Effec) Multi Area IN [ft] plier [sf] Cond. Heat Cap. Dens. R-Value [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol. 3/14/2016 EnergyGauge Summit® v5.10 3 1 PrOZo1F11 I ft. soil, concre[e floor, carpet and rubber pad 30.86 34.00 1 1049.2 0.2681 34.00 113.33 3.73 Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 36.20 14.00 8.00 27000.00 1.00 1200.00 0.80 ❑ ❑ ❑ Plant Equipment Category Size Inst.No Ef. . IPLV Li Water Heaters W-Heater Description Capacit3Cap.Unit I/PRt. Efficiency Loss 1 Electric water heater 50 [Gal] [kW] 0.9500 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] 1 Ext Light 1 Main entries 1 20 20.00 Photo Sensor control 20.00 ❑ 3/14/2016 EnergyGauge Summit® v5.10 4 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F1 [ Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULDb1TntM User Defined 2 0.9000 0.5000 0.4000 ❑ tl-Oth frm Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHea Mat No Acronym Description Used [h.sf.FBtu] [ft] [Btu/mug [lb/cf] t 0 BOARD,1/2IN 178 Mat1178 CARPETW/RUBBERPAD Yes 1.2300 ❑ 265 Matl265 Soil, 1 ft No 2.0000 1.0000 0.5000 100,00 0.2000 0 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,81N,HOLLOW 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ Il Matll1 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAGI/21N 1001 ApLbN1atl001 R 19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 3/14/2016 EnergyGauge Summit® v5.10 5 Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.]F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1045 Mtl Deck, Bar joist, R-19 rigid insulation No No 0.05 0.94 5.30 19.1 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 248 ROOF GRAVEL OR SLAGl/2IN 0.0417 0.000 ❑ 2 1001 R 19 Generic Insulation 0.4147 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sf.F[ [Ib/cf] [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [Ib/cf] [h.sf.F/Btu] 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush (2.25") 0.000 ❑ 3/14/2016 EnergyGauge Summit® v5.10 6 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sf.F] [Ib/cfJ [h.sLFBtu] 1060 Stucco, 8" Block, R 4.1, 1/2" Gyp. Brd. No No 0.11 7.75 41.32 9.0 ❑ Layer Material Material No. 1 123 CONC BLOCK MW,8IN,HOLLOW 2 187 GYP OR PLAS BOARD,1/21N 3 267 0.75" stucco 4 11 2 in. Insulation Thickness Framing IN Factor 0.6667 0.000 ❑ 0.0417 0.000 ❑ 0.0625 0.000 ❑ 0.1670 0.000 ❑ 3/14/2016 EnergyGauge Summit® v5.10 7