HomeMy WebLinkAboutREVIEW COMMENTSPlanning 8 Development Services
Building .8: Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(7721462.6443
PROPERTYINFORMATION
SCANNED
BY
REVIEW COMMENTS St Luce COunty
Address: 10993 Us Hwy 1 Owner(s): '
Mondo Properties Lk;
City / State I Zip: Port St. Lucie, FI 34952 1?
Parcel #: 3414-501-0210-400/9 Jurisdiction: SAINT LUCIE COUNTY
Zoning: CG Lot#: 10 Block: 3
APPLICATION INFORMATION
Permit Number: 1602-0161 ,Stories: Automatic Sprinkler System? No
Permit Type: COMMERCIAL RENOVATION
Contractor Name: Michael J Miranda Fax Number. 772-334-0804
Business Name: Group One Construction 8 Dev Inc
Business Addr. 10302 S Federal Hwy Ste 164 Email: mikemiranda3074@/\o1.Co
City / State / Zip: Port St Lucie, FI 34952
REVIEWS AND COMMENTS
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Deanna Givens 219/2016
2/92016
Comment:
NOTICE OF COMMENCEMENT
2192016
Comment
ELECTICAL SUB AGREEMENT
2I2016
Comment
PLUMBING SUB AGREEMENT '
2/912016
Comment:
HVAC SUB AGREEMENT
2/92016
Comment
SUB SUMMARY
V122016
Comment
3RD SET OF PLANS.
FIRE DEPARTMENT REVIEW
PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE Deanna Givens 2/9/2016 2192016 2/92016
Comment
PE REVIEW COMMENTS (2)
INCOMPLETE Joe Clete 3/162016
2/22/2016
Commend:
— SECOND PLAN REVIEW — FEES DUE UPON RE -SUBMITTAL • PERMIT APPLICATION DESCRIPTION NOT
CLEAR AS TO THE TOTAL SCOPE OF WORK TO BE PERFORMED
Comment
DUCT LAYOUT IS SHOWING 1049 S.F./Al IS SHOWING 1049 S.F. / NEED THE CORRECT SQUARE FOOTAGE
2IW2016
ON PLANS AND ENERGY CALCS AS TENANT SPACE 3 APPEARS TO BE INCREASING " DUCT LAYOUTS
STILL STATE THE INCORRECT SQ FOOTAGE FOR THIS SPACE"
3/162016
Comment:
SUBMIT A FULL COPY OF THE CONSTRUCTION CONTRACT FOR ALL WORK/ VALUATION INCORRECT
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772(462-2172 Fax:(772[462.6443
REVIEW COMMENTS
2
Comment THE UP -STAIR RESIDENTIAL LIVING SPACE AND ELECTRIC WORK REQUIRES SEPARATE PERMITS 1
3/16/2016 PLEASE REMOVE ALL INDICATIONS FOR THIS FROM PROJECT DESCRIPTION ON COV PAGE ` NOTE
STATES THAT STAIRWAY IS TO BE C.M.0 ENCLOSED PER DETAIL / NOT SHOWN ON PLANS
3/16/2016 Comment RESTROOM DETAIL ON A-2 IS NOT COMPLIANT WITH 2O12 ACCESSIBILITY CODE • SEE PUSH / PULL
MANUEVERING CLEARANCES 404.2A.1 FLA ACCESSIBILITY CODE -
3/162016 Comment SHOW THE REQUIRED TOILET AND BATHROOM REQUIREMENTS ON PLANS PER FBC 1210 [ 1210.2.21
3/16/2016 Comment [ 21 REVISED PDF DISCS WILL BE REQUIRED UPON PLAN REVIEW COMPLETION AND PRIOR TO FIRE
DEPT SUBMITTAL
PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 2292016
Comment FULL SET OF ELECTRICAL PLANS NEEDED,TO SHOW ALL LIGHTING,RECP.PER CODE,SERVICE SIZE AND
302016
METERS,ONLY 4 METER NOW WITH 5 BUILD OUTS,1 RES. ABOVE,SHOULD HAVE HOUSE METER AND
ELECTRICAL CIRCUITS,SHOW A.C.CIRCUITS,TOTAL ELECTRICAL LOAD CALS.WALT PRIDE SR.
Comment
THE MAIN ELECTRICAL SERVICE NEEDS TO BE UPDATED,UNDER SIZED,METERS HAVE BEEN ADDED
OVER PASS 20 YEARS,THE SINGLE FAMILY WOULD BE MIM.OF 100 AMPS MAIN SERVICE,EACH OF THE 7
RETAIL WOULD REQUIRE 100 AMP MIM.SERVICE,THERE ARE 7 ADDRESS PLUS RES.PLUS A HOUSE
3/21/2016
SERVICE WOULD BE REQUIRED FOR COMMON AREA LIGHTING,ADDRESS ARE:10981-10983-1098540987-
10993-10997-10999-PLUS RES.NEED TO HAVE TOTAL LOADS PER N.E.CODE,INCLUDING,CNOUIT AND WIRE
SIZES TO ALL PANELS,PANEL BRANCH FEEDER SIZES,AC.FEEDER SIZES,NOTE ALL ELECTRICAL MAIN
FEEDERS TO BE IN CONDUIT,NO S.E.CABLE TO RES.EST SERVICE SIZE 800 AMP SINGLE PHASE 120.240
VOIT WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
COMPLETE Cad Peterson 2242016 2124/2016 2124/2016
Comment
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 22312016'
2232016 Comment
PLEASE CLARIFY WHAT THE JOB DESCRIPTION IS.
223/2016 Comment
PLEASE SHOW OCCUPANT LOADS DID NOT SEE ANY ON A -2
2232016 Comment
THERE ARE 4 SEPARATE UNITS ON THESE PLANS, IF WORK IS TO BE DONE IN ALL OF THEM SEPARATE
PERMITS ARE REQUIRED.
2232016 Comment
IF THERE IS A SINGLE FAMILY RESIDENCE ON SECOND FLOOR YOU WILL NEED THE REQUIRED
PLUMBING FIXTURES PER TABLE 403.1 FL PLUMBING CODE 2014
2232D16 Comment
IF THIS IS A BUILD OUT THEN DRINKING FOUNTAINS AND SERVICE SINKS MAYBE REQUIRED PER TABLE
403.1 FL PLUMBING CODE 2014
3/172016 Comment
STILL NO OCCUPANT COUNT, NOT ON A71
3/172016 Comment:
PLEASE SHOW ALL PLUMBING FIXTURES PER CHAPTER 4 OF THE FLORIDA PLUMBING CODE 2014.
3/17/2016 Comment
2ND REVIEW STOPPED AT THIS POINT UNTIL ALL COMMENTS PRIOR AND CURRENT ARE ADDRESSED.
PLANS EXAMINER REVIEW
COMPLETE Joe Clete 2222016 3/162016 3/162016
Comment:
ZONING REVIEW
PENDING Lydia Galbraith 21122016
2/162016 Comment
IS THE INTERIOR BUILD OUT FOR TENANT ONLY? IF NOT, A SEPARATE APPLICATION FOR EACH
TENANT WILL BE REQUIRED.
2/162016 Comment
PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE
PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
Planning & Development Services
Building & Code. Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982.
Phone:(772)4622172 Fox:(772)462-6443
Address: 10993 Us Hwy 1
City / State / Zip: Port St. Lucie, FI 34952
Parcel#: 3414-501-6210400/9
REVIEW COMMENTS
SCANNED
BY
St. Lucie County
1
Owner(s):
Mondo Properties Llc
Jurisdiction: SAINT LUCIE COUNTY
Zoning: , CG Lot#: 10
APPLICATION INFORMATION
Permit Number: 1602-0161 Stories:
Permit Type: COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name:
Michael J Miranda
Business Name:
Group One Construction & Dev Inc
Business Addr:
10302 S Federal Hwy Ste 164
City / State / Zip:
Port St Lucie, FI 34952
REVIEWS AND COMMENTS
Review Type
DOCUMENTS MISSING
2/9/2016
Comment:
2/9/2016
Comment:
219/2016
Comment:
2/9/2016
Comment:
2/9/2016
Comment:
2112/2016
Comment:
FIRE DEPARTMENT REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
Block: 3
Automatic Sprinkler System? No
Fax Number: 772-334-0804
Status Reviewed By Date Started
PENDING Deanna Givens 21912016
NOTICE OF COMMENCEMENT
ELECTICAL SUB AGREEMENT
PLUMBING SUB AGREEMENT
HVAC SUB AGREEMENT
SUBSUMMARY
3RD SET OF PLANS.
PENDING Tony Jerger
COMPLETE Deanna Givens 2/9/2016
Email: Mikemiranda3074@AoI.Co
m
Date Completed Date Released
21912016 2/9/2016
PLANS EXAMINER ELECTRIC INCOMPLETE Waiter Pride 2/2912016
Comment: FULL SET OF ELECTRICAL PLANS NEEOED,TO SHOW ALL LIGHTING,RECP.PER CODE,SERVICE SIZE AND
3/2/2016 METERS,ONLY 4 METER NOW WITH 5 BUILD OUTS) RES. ABOVE,SHOULD HAVE HOUSE METER AND
ELECTRICAL CIRCUITS,SHOW A.C.CIRCUITS,TOTAL ELECTRICAL LOAD CALS.WALT PRIDE SR.
PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 2/24/2016 2/24/2016 2124/2016
Comment:
.i�. �sra1E (/Oss�tZGZ `S�M�
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462-2172 Fax:(7M)4624443
REVIEW COMMENTS
2
PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 2/2312016
2/23/2016 Comment: PLEASE CLARIFY WHAT THE JOB DESCRIPTION IS.
2/23/2016
Comment:
PLEASE SHOW OCCUPANT LOADS DID NOT SEE ANY ON A -2
Comment:
THERE ARE 4 SEPARATEUNITSON THESE PLANS, IF WORK IS TO BE DONE IN ALL OF THEM SEPARATE
2/2312016
PERMITS ARE REQUIRED.
Comment:
IF THERE IS A SINGLE FAMILY RESIDENCE ON SECOND FLOOR YOU WILL NEED THE REQUIRED
2/2312016
PLUMBING FIXTURES PER TABLE 403.1 FL PLUMBING CODE 2014
Comment:
IF THIS IS A BUILD OUT THEN DRINKING FOUNTAINS AND SERVICE SINKS MAY BE REQUIRED PER TABLE
2/2312016
403.1 FL PLUMBING CODE 2014
PLANS EXAMINER
REVIEW
INCOMPLETE Joe Cicio 2122/2016
2/22/2016
Comment:
PERMIT APPLICATION DESCRIPTION NOT CLEAR AS TO THE TOTAL SCOPE OF WORK TO BE PERFORMED
2/22/2016
Comment:
PLANS ARE NOT CLEAR AS TO THE SCOPE OF WORK TO BE PERFORMED • ANY WORK IN TENANT SPACE
#2 REQUIRES A SEPARATE PERMIT • PLANS SHOW THIS AS WORK AREA
2/22/2016
Comment:
THE i/Ai DETAIL SHOWN ON SHEET Al IS NOT IDENTIFIED ON THE FLOOR PLANS???
2/2212016
Comment:
DUCT LAYOUT IS SHOWING 1049 S.F./ Al IS SHOWING 1049 S.F. / NEED THE CORRECT SQUARE FOOTAGE
ON PLANS AND ENERGY CALCS AS TENANT SPACE 3 APPEARS TO BE INCREASING
2/22/2016
Comment:
IDENTIFY ON PLANS WHERE THE 36" DOOR CUT IS GOING • DETAIL ON Al
Comment:
CALC DESIGNER TO USE THE CORRECT CONSTRUCTION MATERIALS PERTINENT TO THIS JOB • MODIFY
2/22/2016
THE SQUARE FOOTAGE • ROOF IS NOT A METAL BUILDING ROOF • IDENTIFY THE HOT WATER HEATER'
USE THE CORRECT DESIGN CRITERIA [ NOT DAYTONA BEACH ] • ARCHITECT TO SIGN AND SEAL THE
ENERGY GAUGE MANDATORY CHECKLIST IN TRIPLICATE
ZONING REVIEW
PENDING Lydia Galbraith 211212016
2/1612016
Comment:
IS THE INTERIOR BUILD OUT FOR TENANT 3 ONLY? IF NOT, A SEPARATE APPLICATION FOR EACH
TENANT WILL BE REQUIRED.
2/1612016
Comment:
PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE
PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(772)462.6443
REVIEW COMMENTS OUANNED
BY
�t Lucie County
Page 2
Comment: THE UP -STAIR RESIDENTIAL LIVING SPACE AND ELECTRIC WORK REQUIRES SEPARATE PERMITS /
3/16/2016 PLEASE REMOVE ALL INDICATIONS FORTHIS FROM PROJECT DESCRIPTION ON COV PAGE' NOTE
STATES THAT STAIRWAY IS TO BE C.M.0 ENCLOSED PER DETAIL / NOT SHOWN ON PLANS
3/16/2016 Comment: RESTROOM DETAIL ON A-2 IS NOT COMPLIANT WITH 2O12 ACCESSIBILITY CODE • SEE PUSH I PULL
MANUEVERING CLEARANCES 404.2.4.1 FLA ACCESSIBILITY CODE'
3/16/2016 Comment: SHOW THE REQUIRED TOILET AND BATHROOM REQUIREMENTS ON PLANS PER FBC 1210 [1210.2.2 ]
3/16/2016 Comment: [ 21 REVISED PDF DISCS WILL BE REQUIRED UPON PLAN REVIEW COMPLETION AND PRIOR TO FIRE
DEPT SUBMITTAL
PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 2/2912016
Comment:
FULL SET OF ELECTRICAL PLANS NEEDED,TO SHOW ALL LIGHTING,RECP.PER CODE,SERVICE SIZE AND
3/2/2016
METERS,ONLY 4 METER NOW WITH 5 BUILD OUTS,1 RES. ABOVE,SHOULD HAVE HOUSE METER AND
ELECTRICAL CIRCUITS,SHOW A.C.CIRCUITS,TOTAL ELECTRICAL LOAD CALS.WALT PRIDE SR.
Comment:
THE MAIN ELECTRICAL SERVICE NEEDS TO BE UPDATED,UNDER SIZED,METERS HAVE BEEN ADDED
OVER PASS 20 YEARS,THE SINGLE FAMILY WOULD BE MIM.OF 100 AMPS MAIN SERVICE,EACH OF THE 7
RETAIL WOULD REQUIRE 100 AMP MIM.SERVICE,THERE ARE 7 ADDRESS PLUS RES.PLUS A HOUSE
3/21/2016
SERVICE WOULD BE REQUIRED FOR COMMON AREA LIGHTING,ADDRESS ARE:10981-10983-10985-10987-
10993-10997-10999-PLUS RES.NEED TO HAVE TOTAL LOADS PER N.E.CODE,INCLUDING,CNDUIT AND WIRE
SIZES TO ALL PANELS,PANEL BRANCH FEEDER SIZES,A.C.FEEDER SIZES,NOTE ALL ELECTRICAL MAIN
FEEDERS TO BE IN CONDUIT,NO S.E.CABLE TO RES.EST SERVICE SIZE 800 AMP SINGLE PHASE 120-240
VOIT WALT PRIDE SR.
PLANS EXAMINER
MECHANICAL
COMPLETE Carl Peterson 2124/2016 2/2412016 212412016
Comment:
PLANS EXAMINER
PLUMBING
INCOMPLETE Greg Smyth 2123/2016
2/23/2016
Comment:
PLEASE CLARIFY WHATTHE JOB DESCRIPTION IS.
2/23/2016
Comment:
PLEASE SHOW OCCUPANT LOADS DID NOT SEE ANY ON A -2
2/23/2016
Comment:
THERE ARE 4 SEPARATE UNITS ON THESE PLANS, IF WORK IS TO BE DONE IN ALL OF THEM SEPARATE
PERMITS ARE REQUIRED.
212312016
Comment:
IF THERE IS A SINGLE FAMILY RESIDENCE ON SECOND FLOOR YOU WILL NEED THE REQUIRED
PLUMBING FIXTURES PER TABLE 403.1 FL PLUMBING CODE 2014
212312016
Comment:
IF THIS IS A BUILD OUT THEN DRINKING FOUNTAINS AND SERVICE SINKS MAY BE REQUIRED PER TABLE
403.1 FL PLUMBING CODE 2014
3/17/2016
Comment:
STILL NO OCCUPANT COUNT, NOT ON A-1
3/1712016
Comment:
PLEASE SHOW ALL PLUMBING FIXTURES PER CHAPTER 4 OF THE FLORIDA PLUMBING CODE 2014.
3/17/2016
Comment:
2ND REVIEW STOPPED AT THIS POINT UNTIL ALL COMMENTS PRIOR AND CURRENT ARE ADDRESSED.
PLANS EXAMINER REVIEW COMPLETE Joe Cicio 2/2212016 3/1612016 3116/2016
Comment:
ZONING REVIEW PENDING Lydia Galbraith 2/1212016
2/16/2016 Comment: IS THE INTERIOR BUILD OUT FOR TENANT 3 ONLY? IF NOT, A SEPARATE APPLICATION FOR EACH
TENANT WILL BE REQUIRED.
2/16/2016 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE
PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.