Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEREC1v,E` Planning &Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 FEB 2 3 2016 PERrdITTING Certification for Design Load Compliance St. Lucie County, FL Project Name: TREASURE COAST WHOLESALE AUCTION, LLC SCANNED Project Address: 2900INDUSTRIAL 33rd STREET BY Ount Permit Occupancy Type: BUSINESS Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 014 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV . Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD ' End Zone Width: 5.75 ft 5. Mean Roof Height 15 Roof Pitch: 1 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:"J`E"18 G Zone 2: NAEIOrSnN Zone 3: "aE"151NO Zone 4:+32zo-40.4 Zone 5:+32.21.32.a Garage: NA 7. Design Loads: Floor: 100 PSF Roof/Dead: NA PSF Roof/Live: NA Balcony: NA PSF Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: EXISTING PREENGINEERED METAL BUILDING, DESIGNATED SHEAR WALLS FOR NEW OFFICOSTORAGE ONLY 9. Is A Continuous -Load Path Provided? X Yes Not Applicable Explain Why Not: EXISTING PREENGINEERED METAL BUILDING. HOLD DOWNS FOR OFFICEISTORAGE ARE SPECIFIED. 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified/: � / /i� CHRISTOPHER C. KATHE FL PE 36820 Print Name Cert # & Co. Cert Auth. CHRISTOPHER C. KATHE, P.E, S.E. Signature, Date, and Seal 420 OSCEOLA AVENUE, JACKSCN E a'Ac Company Name &Address Revised 07/25/2014 MLL