HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEREC1v,E`
Planning &Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 FEB 2 3 2016
PERrdITTING
Certification for Design Load Compliance St. Lucie County, FL
Project Name: TREASURE COAST WHOLESALE AUCTION, LLC SCANNED
Project Address: 2900INDUSTRIAL 33rd STREET BY
Ount
Permit Occupancy Type: BUSINESS Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 014 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV . Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph X ASD _LRFD ' End Zone Width: 5.75 ft
5. Mean Roof Height 15
Roof Pitch: 1 :12 Parapet: 0 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:"J`E"18 G Zone 2: NAEIOrSnN Zone 3: "aE"151NO Zone 4:+32zo-40.4 Zone 5:+32.21.32.a Garage: NA
7. Design Loads: Floor: 100 PSF Roof/Dead: NA PSF Roof/Live: NA Balcony: NA PSF
Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
EXISTING PREENGINEERED METAL BUILDING, DESIGNATED SHEAR WALLS FOR NEW OFFICOSTORAGE ONLY
9. Is A Continuous -Load Path Provided? X Yes Not Applicable Explain Why Not:
EXISTING PREENGINEERED METAL BUILDING. HOLD DOWNS FOR OFFICEISTORAGE ARE SPECIFIED.
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified/: �
/ /i� CHRISTOPHER C. KATHE FL PE 36820
Print Name Cert # & Co. Cert Auth.
CHRISTOPHER C. KATHE, P.E, S.E.
Signature, Date, and Seal 420 OSCEOLA AVENUE, JACKSCN E a'Ac
Company Name &Address
Revised 07/25/2014 MLL