Loading...
HomeMy WebLinkAboutPROJECT INFORMATION 2Ri ht-Suite® Universal 2017 Short Form Job: 2900 Industrial 33rd Sir... g Date: April 8th, 2016 NEW OFFICES By: Craig C Brooks y Plan: 2900 Industrial 33rd Stre WebReps LLC. Rf�CEi4'�71) AN 2 0 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-8103280 Email: manualj@webmpshvae.com License: CAC064709 For: Treasure Coast Wholesale Auction, LLC 2900 Industrial 33rd Street, Fort Pierce, FL Htg Clg Htg Clg Outside db (OF) 42 88 Inside db (OF) 70 75 Outside RH (%) - 63 Inside RH (%) - 50 Outsidewb (OF) - 78 SCANNED Insidewb (OF) - 63 Daily range (OF) - 20 BY Design TD (OF) 28 13 Moisture diff. (gr/lb) - 61 St. Lucie County Heating Equipment Make Model Type Efficiency Heating Input Heating Output Humidifier Leaving Air Temp Actual Heating Fan Gas furnace 80 AFUE 0 MBtuh 0 MBtuh 5.3 gpd 70.0 OF 1571 cfm Equipment Location System Type Fan Motor Heat Type Fan & Motor Combined Efficiency Static Pressure Across Fan Cooling Equipment Make Model Type COP/EER/SEER Sensible Cooling Latent Cooling Total Cooling Leaving Air Temp Actual Cooling Fan NEW OFFICES PEAKCV PACKAGE 0 % 0 in H2O Split AC 0 0 MBtuh 0 MBtuh 0 MBtuh 55.0 OF 1571 cfm NAME Area ft2 Heat Loss Sensible Gain Latent Gain Htg cfm Clg cfm Time Office 1 94 1118 2125 354 96 94 Jul 1700 LST Office 2 94 733 1997 354 61 88 Jul 1700 LST Conference Room 175 1648 3353 684 139 148 Jul 1700 LST HVAC 14 183 249 70 16 11 Jul 1700 LST Office 3 142 803 2110 534 65 93 Jul 1700 LST Hall 63 193 886 251 14 39 Jul 1700 LST Entry 667 6726 11816 4258 528 523 Jul 1700 LST Computer 23 227 362 87 19 16 Jul 1700 LST Hall 2 88 270 1239 343 20 55 Jul 1700 LST Supply Clst 66 815 1152 257 70 51 Jul 1700 LST Breakroom 84 716 1504 335 60 67 Jul 1700 LST Employee Restroom 92 685 1502 351 57 66 Jul 1700 LST Ladies Restroom 155 2354 3304 1438 182 146 Jul 1700 LST e A__- onAQ 9nna AGOA OA9 Awe r..l i7nn i eT JulenJ IOG JV V JJVI 11J G-IJ IIJ JYI IIVV 1V 1 + wrightsoft' RlghtSufte® Universal 201717.0.01 RSU16998 ...ice 2900 Industrial 33 rd StmetFort Pierce.mp Calc = RTS Fmnt Door faces: SE NEW OFFICES 1937 1 19517 1 35507 1 10851 1 1571 1571 Jul 1700 LST 2016-Apr-08 13:02:49 wrightsofC RightSuite® Univemal201717.0.01 RSU16996 Page 2 ...ice 2900 Industrial 33 rd StreetFort Plerce.rup Cale = RTS Front Door faces: SE Right -Suite® Universal 2017 Load Summary Job: 2900 Industrial 33rd Str... Date: April 8th, 2016 NEW OFFICES By: Craig C Bmoks WebRepS LLC. Plan: 2900 Industrial 33rd Stre 1892 Commerce Avenue, Vera Beach, FL 32960 Phone: 800-810-3280 Email: manualj@webrepshvac.com License: CAC054709 Project• • For: Treasure Coast Wholesale Auction, LLC 2900 Industrial 33rd Street, Fort Pierce, FL ne NEW FILES, 1. DESIGN CONDITIONS at Jul 1700 LST Peak load at Jul 1700 LST Inside: 75 OF Outside: 88 OF TD: 13 OF RH: 63 % MoistDiff: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 1943 3. TRANSMISSION GAINS Sensible 8487 Walls: 2601 - - Glass: 467 - - Doors: 1490 - - Partitions: 0 - - Floors: 0 - - Ceilings: 3930 4. INTERNAL HEAT GAIN Sensible Latent 20060 3875 Occupants: 4550 3875 - - Lights: 11036 - - Motors: 0 - - Appliances: 4474 0 5. INFILTRATION: Outside air cfm: 167 2386 6976 6. SUBTOTAL: Space load Sensible Latent 32877 10851 Envelope 32877 10851 - - Less external 0 - - Redistribution 0 0 - 7. SUPPLYDI7CT 1644 - S. SUBTOTAL: Space load + supply duct 34521 - Actual cfm: 1571 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 0 0 0 10. RETURNAIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 986 - 12. TOTAL LOADS ON EQUIPMENT 35507 10851 M1? N HE4TING_L'OAD=...w.f. s a t 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 11054 Walls: 3101 - Glass: 1206 - Doors: 1154 - Partitions: 0 - Floors: 3746 - Ceilings: 1847 15. INFILTRATION: Outside air cfm: 167 5144 16. SUBTOTAL: Space load 16198 Envelope 16198 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT, 810 18. VENTILATION: Make-up air cfm: 0 0 19. HUMIDIFICATION 2023 Piping 0 20. RETURN DUCT 486 21. TOTAL HEATING LOAD ON EQUIPMENT 19517 -"��- 2016-Apr-08 13:02:49 vvr1ght501fC RightSuReS Univemal20l7l7.0.01 RSU16998 page 1 ...ice 2900 Industrial 33 rd SlreelFort Pierce.mp Calc = RTS Fmnt Doorfaces: SE Job #: 2900 Industrial 33rd Street Performed by Craig C Brooks for: Treasure Coast Wholesale Auction, LLC 2900 Industrial 33rd Street Fort Pierce, FL WebReps LLC. 1892 Commerce Avenue Vero Beach, FL 32960 Phone: 800-810-3280 manualj@webrepshvac.com Scale: 1 : 91 Page 1 RightSuAe® Universal 2017 17.0.01 RSU16998 2016-Apr-08 13:03:12 ...vial 33 rd StreetFort Pierce.rup Project Name: TC Wholesale Auction Project Title: New Project Address: 2900 Industrial 33rd Street State: FL Zip: 34946 Owner: Boa Riggins EnergyGauge Summit® v5.10 INPUT DATA REPOR Proiect Information Orientation: North Building Type: Office Building Classification: New Finished building No.of Stories: I GrossArea: 1939 SF Zones No Acronym Description Type Area Isfl Multiplier Total Area [sfl 1 TC Wholesale Offices CONDITIONED 1938.6 1 1938.6 ❑ Spaces No Acronym Description Type Depth [ft] Width Height Multi [ft] [ft] plier Total Area [sf] Total Volume [cf] 4/8/2016 EnergyGauge Summit® v5.10 1 In Zone: TC Wholesale 1 TC Wholesale Offices Office - Open Plan 44.03 44.03 9.00 1 1938.6 17447.8 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: TC Wholesale In Space: TC Wholesale I Compact Fluorescent General Lighting 17 40 680 Manual On/Off 19 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf F] Capacity [lb/cf] [h.sf.FBtu] [Btu/s£F] In Zone: TC Wholesale 1 Offices Metal 176.00 9.00 1 1584.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+R1 1Batt/5/8"Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier Isfl In Zone: TC Wholesale In Wall: TC Wholesale 1 Offices User Defined Yes 1.2500 0.82 0.76 3.00 4.00 11 132.0 Doors No Description Type Shaded? Width H (Effec) Mufti Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btulhr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] 4/8/2016 EnergyGauge Summit® v5.10 In Zone: In Wall: Roofs No Description Type Width Vt] H (Effec) Multi [ft] pher Area [sf] Tilt Cond. Heat Cap [deg] [Btu/hr. Sf. F] [Btu/sf. F] Dens. R-Value [Ib/cf] [h.sf.FBtu] In Zone: TC Wholesale 1 Offices Mtl Bldg Roof/R-19 Batt 44.03 44.03 1 1938.6 0.00 0.0492 1.34 9.49 20.3 ❑ Skylights No Description Type U SHGC Vis.Trans [Btu/hr sf F] W H (Effec) Multiplier [ft] [ft] Area Total Area [SfJ [Sf] In Zone, In Roof: Floors No Description Type Width [ft] H (Effec) Multi [ft] plier Area [sf[ Cond. Heat Cap. Dens. [Btu/hr. sf. F] [Btu/sG F] [lb/cf[ R-Value [h.sf.FBtu] In Zone: TC Wholesale 1 Offices 1 ft. soil, concrete floor, carpet and rubber pad 44.03 44.03 1 1938.6 0.2681 34.00 113.33 3.73 ❑ Systems 4/8/2016 EnergyGauge Summit® v5.10 TC Wholesale System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 59000.00 14.00 8.00 34130.00 1.00 1500.00 0.80 ❑ ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV I Hermetic Centrifugal chiller Cooling Equipment 5.0 [Tons] 1 5.90 [COP] 6.10 Water Heaters W-Heater Description CapacitlCap.Unit I/P Rt. Efficiency Loss I Electric water heater 50 [Gal] 3000 [kW] [Ef] [Bm/h] ❑ Ext-Lighting Description Category No. of Luminaires Watts per Area/Len/No. of units Luminaire [sf/ft/No] Control Type Wattage [W] 1 Ext Light 1 Uncovered Parking Areas — 1 Parking lots and Drives 750 0.00 Photo Sensor control 750.00 ❑ Piping No Type Operating Temperature [F] Insulation Conductivity [ Btu-in/h.sSF] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? 4/8/2016 EnergyGauge Summit® v5.10 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/b.sLFJ ASHULSglClrAll User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 187 Mat1187 UYP UK PLAN No BOARD,1/21N 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Matl4 Steel siding No 0.0002 0.0050 21,0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc+RII Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu} 1055 Metal siding/2x4@24"+Rl lBatt/5/8 "Gyp No No 0.09 1.07 19.38 10.9 ❑ Layer Material Material Thickness Framing No. fit] Factor 1 4 Steel siding 0.0050 0.000 ❑ 4/8/2016 EnergyGauge Summit® v5.10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sLF] [lb/cf] [h.sf.FBtu] 1055 Metal siding/2x4@24"+R11Batt/5/8"Gyp No No 0.09 1.07 19.38 10.9 ❑ Layer Material Material Thickness Framing No. N Factor 2 271 2x4@24" oc+RII Batt 0.2917 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. A Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/b.sf.F] [Btu/sLF] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 4/8/2016 EnergyGauge Summit® v5.10 6 s i F Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: This Checklist An Input report generated from the software just after completing compliance calculations without any further changes The full compliance report generated by the software that contains the project summary, complaince summary, certifications and detailed component compliance reports Boxes appropriately checked in the Miscellanous report generated by the software at the end of the compliance report EnergyGauge Summit® FlafGom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 1 of 12 PROJECT SUMMARY Short Desc: TC Wholesale Auction Description: New Project Owner. Boa Riggins Addressl: 2900 Industrial 33rd Street City: Fort Pierce Address2: State: FL Zip: 34946 Type: Office Class: New Finished building Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Conditioned Area: 1939 SF Conditioned & UnConditioned Area: 1939 SF No of Stories: 1 Area entered from Plans 1937 SF Permit No: 0 Max Tonnage 5 If different, write in: Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 1,138.0 1,290.0 PASSED PASSES PASSES PASSES PASSES PASSES No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 — — — An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 2 of 12 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code c C. Prepared By: MCraig C Brooks Building Official: Date: 2/112016 Date: I certify that this building is in compliance with the FLodda Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (`) that the system design is in compliance with the Florida Energy Efficiency Code Architect Reg No: Electrical Designer. Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer. Reg No: (`) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 3 of 12 Project: TC Wholesale Auction Title: New Project Type: Office Building End Uses 1) Proposed 2) Baseline Total 72.90 97.20 $1,138 $1,518 ELECTRICITY(MBtulkWhl$) 72.90 97.20 21349 28478 $1,138 $1,518 AREA LIGHTS 7.10 20.30 2083 5937 $Ill $316 MISC EQUIPMT 29.10 29.10 8521 8521 $454 $454 PUMPS & MISC 0.10 0.10 26 26 $1 $1 SPACE COOL 18.60 22.40 5458 6570 $291 $350 SPACE HEAT 1.40 1.60 396 474 $21 $25 VENT FANS 16.60 23.70 4865 6950 $259 $370 Credits Applied: None PASSES Passing Criteria =1290 Design (including any credits) =1138 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 75% EnergyGauge Summ * FlaICom-2014. TAM 2014-1.0 Compliant Software. Effective Dale: June 30, 2015 2/11/2016 Page 4 of 12 Project: TC Wholesale Auction Title: New Project Type: Office (WEA Fite: DAYTONABEACH.TMY) External Lighting Compliance Description Category Tradable? Allowance AmorLength ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light I Uncovered Parking Areas — Yes 0.15 750 Parking lots and Drives Tradable Surfaces: 750 (W) Allowance for Tradable: 750 (W) PASSES All External Lighting: 750 (W) Complicance check includes a excess/Base allowance of 750.00(W) Project: TC Wholesale Auction Title: New Project Type: Office (WEA File. DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP once TC Wholesale 16 Office -Open Plan 1,939 19 1 PASSES PASSES Project: TC WholesaleAuction Title: New Project Type: Office (WEA File: DAYTONABEACILTMY) System Report Compliance TC System 1 Constant Volume Air Cooled No. of Units Wholesale Split System <65000 Btu/hr 1 Component Category Capacity Design Eft Design IPLV Comp - Elf Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 59000 14.00 12.23 8.00 PASSES Split System <65000 Btu/b Cooling Capacity Heating System Electric Furnace 34130 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1500 0.80 0.82 PASSES System -Supply Constant Volume PASSES EnergyGauge Summit® FlalCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 5 of 12 Plant Compliance Description Installed Size Design Min Design No Eff Eff IPLY Min Category Comp IPLY liance Hermetic Centrifugal 1 5 5.900 5.547 6.100 chiller 5.901 Water Chilling Packages PASSES (Elec), Water Cooled (centrifugal), 0 to 300 tons PASSES Project: TC Wholesale Auction Title: New Project Type: Office (WEA File: DAYTONABEACH.TMY) Water Heater Compliance D Description Type Design Min Category Eff Eff Design Max Comp Loss Loss fiance Water Heater 1 Electric water heater > 12 [kW] 241.5C PASSES PASSES Piping System Compliance Category Pipe Din Is Operating Ins Cond [inches] Runout? Temp [Btu-in/hr IF] SF.F1 Ins Req Ins Compliance Thick [in] Thick [in] None EnergyGauge Summit® FWGom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 6 of 12 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes N/A Ex Air Leakage C402.4.1,C402.4.2 Envelope The building envelope contains a continuous air U U u barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air harrier penetrations are sealed in an approved manner. Air Leakage C402.4.3,C402.4.4 Envelope Factory -built fenestration and doom are labeled ❑ ❑ ❑ as meeting air leakage requirements. Air Leakage 0402A.7 Envelope Vestibules are installed on all building entrances. Doors have self -closing devices. Air Leakage C402.4.1.1 Envelope All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather shipped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. Air Leakage C402.4.6 Envelope I*atherseals installed on all loading dock cargo doors. Air Leakage C402.4.8 Envelope Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaim housing. Fenestrafion C303.1.3 Envelope Fenestration products rated in accordance with ❑ ❑ ❑ NFRC. Fenestration C303.1.3 Envelope Fenestration products are certified as to performance labels or certificates provided. Fenestration C402.2.7 Envelope Urs -factor of opaque doom associated with the building thermal envelope meets requirements. Insulation C303.2 Envelope Below -grade wall insulation installed per manufacturers instructions. Insulation C303.2 Envelope Slab edge insulation installed per manufacturers instructions. Insulation C402.2.6 Envelope Slab edge insulation depWength. Slab insulation ❑ ❑ ❑ extending away from building is covered by pavement or>= 10 inches of soil. Insulation C403.2.7,C408.2.8,C4i Envelope Exterior insulation protected against damage, ❑ ❑ ❑ sunlight, moisture, wind, landscaping and equipment maintenance activities. Insulation C402.4.2.1 Envelope Roof R-value. For some ceiling systems, ❑ ❑ ❑ verification may need to occur during Framing Inspection. Insulation C303.2 Envelope Roof insulation installed per manufacturers ❑ ❑ ❑ instructions. Blown or poured loose -fill insulation is installed only where the roof slope is <=3 in 12. Insulation C402.2.1 Envelope Skylight curbs are insulated to the level of roofs ❑ with insulation above deck or R-5. Insulation C402.2.1.1 Envelope High-albedo roofs satisfy one of the following: 3-yearaged solar reflectance>= 0.55 and thermal emittance>=0.75, 3-yearagedsolarreflectance index>=64.0, initial year solar reflectance >= 0.70 and thermal emittance>= 0.75, or initial year solar Insulation C303.2 Envelope Above -grade wall insulation installed per ❑ ❑ manufacturers instructions. Insulation C303.2 Envelope Floor insulation installed per manufacturers instructors. Insulation C303.1 Envelope Building envelope insulation is labeled with ❑ El R-value or insulation certificate providing R-value and other relevant data. EnergyGauge Summit® FWCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 7 of 12 Insulation C303.2.1 Envelope Exterior insulation is protected! from damage with - a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Insulation C402.2.1 Envelope Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Controls C4052.4 Exterior Lighting Automatic lighting controls for exterior lighting installed. Wattage C405.6 Exterior Lighting Exterior grounds lighting over 100 W provides >60 ❑ 0 ❑ Im/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Wattage C405.6.2 Exterior Lighting Exterior lighting power is consistent with what is ❑ ❑ shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Controls C4052.21 Interior Lighting Automatic cols to shut off all building lighting ntro ❑ ❑ ❑ installed in all buildings. Controls C405.2.1.1 Interior Lighting Independent lighting controls installed per ❑ ❑ 11 approved lighting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.1.2 Interior Lighting Lighting controls installed to uniformly reduce the El ❑ ❑ lighting load by at least 50%. Controls C4052.2.3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting. Controls C405.2.3 Interior Lighting Sleeping units have at least one master switch at the main entry door that controls wired luminaires and sreceptacles. Controls C405.2.2.2 Interior Lighting Occupancypancy sensors installed in required spaces. ❑ El ❑ Controls C405.2.2.3 Interior Lighting Primary sidelighted areas are equipped with ❑ ❑ required lighting controls. Controls C405.2.2.3 Interior Lighting Enclosed spaces with daylight area under ❑ skylights and rooftop monitors are equipped with required lighting controls. Controls C405.2.3 Interior Lighting Separate lighting control devices for specific uses ❑ ❑ ❑ installed per approved lighting plans. Controls C405.3 Interior Lighting Fluorescent luminaires within odd numbered lamp configurations that are with 10 feet center to center (if recess mounted) or are within 1 foot edge to edge (if pendant or surface mounted) shall be tandem wired. Wattage C405.4 Interior Lighting Exit signs do not exceed 5 watts per face. ❑ ❑ Wattage C405.2.3 Interior Lighting Additional interior lighting power allowed for ❑ ❑ special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage C405.5.2 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. HVAC C403.2.4.5 Mechanical Freeze protection and snowlice melting system sensors for future connection to controls. HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. El El 11 Air Leakage C402.4.5.1 Envelope Stair and elevator shaft vents have motorized dampers that automatically dose. Air Leakage C402.4.5.2 Envelope Outdoor air and exhaust systems have motorized ❑ dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. HVAC C403.2.5.1 Mechanical Demand control ventilation provided for spaces 0 El El >500 fit and >25 people/l000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow>3,000 cfm. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 8 of 12 HVAC C403.2.8.1 Mechanical Piping Insulation exposed to weather is protected from damage (due to sun, moisture, wind, eta). HVAC C403.2.7 Mechanical HVAC ducts and plenums Insulated. Where ducts ❑ or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC C403.2.8 Mechanical Thermally ineffective panel surfaces of sensible ❑ ❑ ❑ heating panels have insulation >= R-3.5. HVAC C403.2.7 Mechanical Ducts and plenums sealed based on static pressure and location. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. HVAC C403.2.6 Mechanical Exhaust air energy recovery on systems meeting Table C403.2.6 HVAC C403.2.11 Mechanical Unendosed spaces that are heated use only radiant heat HVAC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by ❑ El a thermostat control. HVAC C403.2.4.2 Mechanical Thermostatic controls have a 5 °F deadband. HVAC C403.2A.2 Mechanical Temperature controls have setpomt overlap ❑ El ❑ restrictions. HVAC C403.2A.3 Mechanical Each zone equipped with setback controls using 1:1 El El automatic time dock or programmable control system. HVAC C403.2.4.3 Mechanical Automatic Controls: Setback to 55°F(heat)and ❑ ❑ 85°F (cool); 7-day dock, 2-hour occupant override, o backup SYSTEM —SPECIFIC C404.3 Mechanical ure n Temperature controls installed on service water ❑ ❑ ❑ heating systems (110 °F for dwelling units and lavatories in public restrooms and 90 °F for other occupancies.) SYSTEM_SPECIFIC C404.4 Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM —SPECIFIC C404.2 Mechanical Heat traps installed on non -circulating storage water tanks. SYSTEM —SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM —SPECIFIC C403.4.2 Mechanical VAV fan >= 7.5 hp are driven by mechanical or electrical variable speed drive, or driven by vane -axial with variable speed blades, or operate with motor demand <=30 % design kW at 50 design flow - calculations required SYSTEM —SPECIFIC C403.2.8 Mechanical HVAC piping insulation thickness. Where piping 0 El is installed in or under a slab, verification may need to occur during Foundation Inspection. SYSTEM —SPECIFIC C403.27.1.3 Mechanical Ductwork operating>3 in. water column requires 1-1 El El air leakage testing. SYSTEM —SPECIFIC C403.3.1,C403.3.1.1 Mechanical Air economizers provided where required, meet 11 ❑ the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air dudng operation. SYSTEM —SPECIFIC C403.3.1,C403.4.1 Mechanical Water economizers provided where required, meet the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM —SPECIFIC C403.4.1A Mechanical Economizer operation will not increase heating energy use during normal operation. SYSTEM —SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and El cooling and sequence heating and cooling to each zone. SYSTEM —SPECIFIC C403.4.3.1 Mechanical Three -pipe hydronic systems using a common 11 El El return for hot and chilled water are not used. EnergyGauge Summit® FlalGom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 9 of 12 SYSTEM -SPECIFIC C403.4.3.2 Mechanical Two -pipe hydronic systems using a common 1__I U ❑ distribution system have controls to allow a deadband >=15 °F, allow operation in one mode for at least 4 him before changeover, and have rest controls to limit heating and cooling supply temperature to —30 -F. SYSTEM -SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to common water loop meet heat rejection and heat addition requirements. SYSTEM -SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. SYSTEM -SPECIFIC C403.2.10.1 Mechanical HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM -SPECIFIC C403.2.10.2 Mechanical HVAC fan motors not larger than allowable limits. SYSTEM -SPECIFIC C403.4.2 Mechanical VAV fan motors>=7.5 hp to be driven by variable speed drive, have a vane -axial fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM -SPECIFIC C403.4.2.1 Mechanical VAV fans have static pressure sensors positioned so setpoint <=1/3 total design pressure. SYSTEM -SPECIFIC C403.4.2.2 Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM -SPECIFIC C403.4.5A Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM -SPECIFIC C403.4.3.4 Mechanical Hydronic systems greater than 300,000 BtWh designed for variable fluid flow. SYSTEM -SPECIFIC C403.4.3.5 Mechanical Reduce flow in pumping systems >10 hp to multiple chillers or boilers when others are shut down. SYSTEM -SPECIFIC C403A.3.4 Mechanical Temperature reset by representative building 1:1 El El loads in pumping systems for chiller and boiler systems Btu/h. SYSTEM -SPECIFIC C403.4.3.3.3 Mechanical Two-posNon automatic valve interlocked to shut wo-pos>on auto ❑ ❑ ❑ off water flow when hydronic heat pump with pumping system>70 hp Is off. SYSTEM -SPECIFIC C403.4.4 Mechanical Fan systems with motors>=7.5 hp associated El ❑ ❑ with heat rejection equipment to have capability to operate at 213 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM -SPECIFIC C403.4.6 Mechanical Condenser heat recovery system that can heat ❑ water to 85 °F or provide 60°% of peak heat rejection is installed for preheating of service hot water in 24/7 facility, water cooled systems reject >6 MMBtu, SHW load >=1 MMBtu. C403.4.7 Mechanical Hot gas bypass limited to: El 1-1 El <=240 kBtu/h - 50% >240 k8lu/h-25% SYSTEM -SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency requirements - SYSTEM -SPECIFIC C403.2A2 Mechanical Heating and cooling to each zone is controlled by ❑ a thermostat control. Minimum one humidity control device per installed humidificationtdehumidification system. SYSTEM -SPECIFIC C403.2A.3.3 Mechanical Systems include optimum start controls. ❑ ❑ El SYSTEM -SPECIFIC C403.2.4.1.1 Mechanical Heal pump controls prevent supplemental electric El ❑ ❑ resistance heat from coming on when not needed. SYSTEM -SPECIFIC C404.3 Mechanical Public lavatory faucet water temperature —110°F. El El 0 SYSTEM -SPECIFIC C404.5 Mechanical All piping in circulating system insulated ❑ SYSTEM -SPECIFIC C404.5 Mechanical First 8 ft of outlet piping is insulated El El ❑ EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 10 of 12 SYSTEM —SPECIFIC SYSTEM_ SPECIFIC SYSTEM —SPECIFIC SYSTEM —SPECIFIC SYSTEM —SPECIFIC SYSTEM —SPECIFIC Testing C404.5 C404.6 C404.7.1 C404.7.3 C404.7.2 r403.2.3 C408.2.3.2 MandatoryAdditional Ell C406 Insulation C402.2.8 Plan Review - C103.2 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 Plan Review 0406 Plan Review C4023.22 Post Construction C408.2.5.1 Mechanical All heat traced or externally heated piping insulated Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank Mechanical Pool heaters are equipped with ontoff switch and no continuously burning pilot light Mechanical Vapor retardant pool covers are provided for heated pools and permanently installed spas. Mechanical Time switches are installed on all pool heaters and pumps. Mechanical Centrifugal fan openrircuit cooling towers having combined rated capacity>= 1100 gpm meets minimum efficiency requirement: >=38.2 gpnVhp. Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Project Efficient HVAC performance, efficient lighting system, or on -site supply of renewable energy consistent with what is shown the approved plans. Project Bottom surface of floor structures incorporating radiant heating insulated to >=R-3.5. Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Exterior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shout Interior Lighting Plans, specifications. and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shout Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering st Mechanical Plans, specifications, and/or calculations provide all Infomhation with which compliance can be determined for the service water heating systems andequipmentand documentwhereexrxptions to the standard are claimed. Hot water system sized per manufact Project Plans, specincaflons, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Envelope Skylights in office, storage, automotive service, manufacturing, non -refrigerated warehouse, retail store, and distribution/soring area have a measured haze value> 90 percent unless designed to exclude direct sunlight Exterior Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Interior Lighting Furnished as -built drawings for electric power systems within 30 days of system acceptance. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ �Ni EnergyGauge Summit®Fla/Cbm-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/1112016 Page 11 of 12 Post Construction C303.3,C408.2.5.2 Interior Lighfing Furnished O&M instructions for systems and equipment to the building owner or designated Post Construction 0408.3 Interior Lighting representative. Lighting systems have been tested to ensure El ❑ ❑ propercelibmtion, adjustment, programming, and Post Construction C408.2.5.7 Mechanical operation. Famished HVAC as -built drawings submitted ❑ ❑ ❑ within 90 days of system acceptance. Post Construction C303.3,C408.2.5.2 Mechanical Famished O&M manuals for HVAC systems ❑ ❑ ❑ within 90 days of system acceptance. Post Construction C408.2.5.3 Mechanical An air and/or hydronic system balancing report is ❑ ❑ ❑ provided for HVAC systems. Post Construction C408.2.1 Mechanical Commissioning plan developed by registered ❑ ❑ ❑ design professional or approved agency. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and ❑ ❑ ❑ certified by registered design professional or Post Construction C408.2.5.4 Mechanical approved agency. Final commissioning report due to building owner El ❑ ❑ Within 90 days of receipt of certificate of Post Construction C406.2.3.1 Mechanical occupancy.❑ HVAC equipment has been tested to ensure ❑ ❑ proper operation. Post Construction C408.2.3.3 Mechanical Economizers have been tested to ensure proper ❑ ❑ ❑ operation. EnergyGauge SummirM Fis/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 2/11/2016 Page 12 of 12 - Duct System Details Job: April8Industrial33rd Street Y Date: April th, 2616 NEW OFFICES By: Craig C Brooks WebREPS WebReps LLC. Plan: 2900 Industrial 33rd stre 1-800-810-3280 1892 Commerce Aenue, Vero Beach, FL 32960 Phone: 800-8103280 Email: manuall@mbrepshv c.eom License: CAC054709 Calculation method: EqualFric Equipment pressure losses ( in H2O ): Duct system losses ( in H2O ): Total fan pressure ( in H2O ): Fan air flow( cfm ): Supply FR ( in/100ft ): 0.100 Heating 0.230 SCANNED 0.183 BY 0.413 St. Lucie County 1600 Supply Branch Details Return FR ( in/100ft ): 0.100 Cooling 0.230 0.160 0.390 1600 Duct Name HtgLoad HtgAVF Dsn AVF Veloc Wdth Length F.Loss Tot.Loss (Btuh) (cfm) (cfm) (fpm) (in) (ft) (in H2O) (in H2O) Parent Trunk Name ClgLoad ClgAVF Shape Matl Hght S.Loss Aj+Vav Cum.Loss (Btuh) (cfm) (in) (in H2O) (in H2O) (in H2O) Breakroom . 1039 47 c 110 560 6 9.5 0.011 0.027 st11 2363 107 Rect VinlFlx 0.016 0 0.125 Computer 401 18 h 40 460 4 9.5 0.007 0.025 st9 735 33 Rect VinlFlx 0.0.18 0 0.112 Conference Room 1448 66 c 158 593 7 16.0 0.012 0.037 st6 3407 155 Rect VinlFlx 0.025 0 0.103 Employee Restroom 637 29 c 81 597 5 6.0 0.012 0.026 st12 1749 80 Rect VinlFIX 0.014 0 0.131 Entry 2784 127 c 283 518 10 4.5 0.011 0.015 st8 6079 276 Rect VinlFlx 0.003 0 0.100 Entry -A 2784 127 c 283 518 10 5.5 0.011 0.015 st7 6079 276 Rect VInIFIX 0.004 0 0.088 Ladies Restroom 1894 86 h 190 544 8 3.0 0.004 0.007 st13 3313 151 Rect VinlFlx 0.003 0 0.128 Mens Restroom 2507 114 h 251 569 9 3.0 0.005 0.008 st14 3799 173 Rect VinlFlx 0.003 0 0.140 Office 1 1030 47 c 107 543 6 9.0 0.003 0.017 2293 104 Rect VinlFlx 0.014 0 0.017 Office 2 645 29 c 99 506 6 7.5 0.009 0.019 st4 2135 97 Rect VinlFlx 0.010 0 0.040 Office 3 783 36 c 114 580 6 10.9 0.004 0.023 2449 111 Rect VinlFlx 0.019 0 0.023 Wrightsoft° RightSuiteO Unhereal 201717.0.03 RSU169M ...ice 29M lndushial 33 rd SheetFad Pimce.rup Calc = RTS Front Doorfacec: SE 201&Apr-21 12:04:04 Page 1 F�-k Duct System Summary Job: 2900 Industrial 33rd Street NEW OFFICES Date: By: April 8th, 2016 Craig C Brooks WebREPS WebReps LLC. pan: 2 00Industrial 33rd Stre 1-800-810-3280 1892 Commerce Annue, Vero Beach, FL 32960 Phone: B00-Bl"280 Email: mamm1j@Mbrepslnac.com License: CAC054709 Calculation method: EqualFric Supply FR ( in/100ft ): 0.100 Return FR ( in/10Oft ):0.100 Heating Cooling Equipment pressure losses ( in H2O ): 0.230 0.230 Duct system losses ( in H2O ): 0.183 0.160 Total fan pressure ( in H2O ): 0.413 0.390 Fan air flow ( cfm ): 1600 1600 Supply Name Htg Load (Btuh) Clg Load (Btuh) Design AVF (cfm) Veloc (fpm) Shape Duct Size (in) Duct Mall Cumm. Loss (in H2O) Breakroom 1039 2363 c 110 560 Round 6 VinlFlx 0.125 Computer 401 735 h 40 460 Round 4 VinIFIX 0.112 Conference Room 1448 3407 c 158 593 Round 7 VinlFlx 0.103 Employee Restroom 637 1749 c 81 597 Round 5 VinlFlx 0.131 Entry 2784 6079 c 283 518 Round 10 VinlFlx 0.100 Entry -A 2784 6079 c 283 518 Round 10 Vin1Flx 0.088 Ladies Restroom 1894 3313 h 190 544 Round 8 VinlFlx 0.128 Mens Restroom 2507 3799 h 251 569 Round 9 VinlFlx 0.140 Office 1 1030 2293 c 107 543 Round 6 VinlFlx 0.017 Office 2 645 2135 c 99 506 Round 6 VinlFlx 0.040 Office 3 783 2449 c 114 580 Round 6 VinlFlx 0.023 Name Htg Load (Btuh) Clg Load (Btuh) Design AVF (cfm) Veloc (fpm) Shape Duct Size (in) Duct Matl Pres Loss (in H2O) st1 14139 29658 h 1418 681 Rect 25 x 12 RectFbg 0.001 st2 14139 29658 h 1418 681 Rect 25 x 12 RectFbg 0.001 stl2 5038 8861 h 505 606 Rect 10 x 12 RectFbg 0.007 st11 6077 11224 h 610 610 Rect 12 x 12 RectFbg 0.002 st7 12045 24117 h 1208 690 Rect 21 x 12 RectFbg 0.006 st6 13493 27524 h 1353 677 Rect 24 x 12 RectFbg 0.003 st5 13493 27524 h 1353 677 Rect 24 x 12 RectFbg 0.002 st4 14139 29658 h 1418 681 Rect 25 x 12 RectFbg 0.004 st3 14139 29658 h 1418 681 Rect 25 x 12 RectFbg 0.002 st8 9262 18038 h 929 697 Rect 16 x 12 RectFbg 0.013 st9 6478 11959 h 650 557 Rect 14 x 12 RectFbg 0.003 st10 6077 11224 h 610 610 Rect 12 x 12 RectFbg 0.004 stl3 4401 7111 h 441 662 Rect 8 x 12 RectFbg 0.015 st14 2607 3799 h 251 503 Rect 6 x 12 RectFbg 0.012 LIJ 2016-Aar-21 12:04:04 wrightsOft' RighlSuile® Uniwma1201717.0.03 RSU16998 Page 1 ...ice 2900 industrial 33 rd StreetFW Pieme.mp Calc = RTS Front Door faces: SE Htg Clg Design Veloc Shape Duct Duct Cumm. Name Load Load AVF Size Matt Loss (Btuh) (Btuh) (cfm) (fpm) (in) (in H2O) rbi 15952 34400 1 c 1600 686 Rect 28 x 12 VinlFlx 0.043 2016-Apr21 12:04:04 wrightsofr RightSuOe® Uniwmgl201717.0.03 RSU16998 Page 2 ...Ice 2900 industrial 33 rd Stro tFortPime.mP Calc = RTS Front Dow faces: SE Supply Trunk ;Details Duct Name HtgLoad HtgAVF Dsn AVF Veloc Wdth Length F.Loss Tot.Loss (Btuh) (cfm) (cfm) (fpm) (in) (ft) (in H2O) (in H2O) Parent Trunk Name ClgLoad ClgAVF Shape Mat[ Hght Sloss Aj+Vav Cum.Loss (Btuh) (cfm) (in) (in H2O) (in H2O) (in H2O) st1 14139 643 h 1418 681 25 1.0 0.014 0.014 29658 1348 Rect RectFbg 12 0.001 0 st2 14139 643 h 1418 681 25 1.5 0 0.001 st1 29658 1348 Rect RectFbg 1 12 0.001 0 st12 5038 229 h 505 606 10 7.5 0.000 0.007 st11 8861 403 Rect RectFbg 12 0.007 0 st11 6077 276 h 610 610 12 2.5 0.005 0.007 st10 11224 510 Rect RectFbg 12 0.002 0 st7 12045 548 h 1208 690 21 8.0 0.001 0.007 st6 24117 1096 Rect RectFbg 12 0.006 0 SW 13493 613 h 1353 677 24 4.5 0.039 0.043 st5 27524 1251 Rect RectFbg 12 0.003 0 st5 13493 613 h 1353 677 24 2.5 0.000 0.002 st4 27524 1251 Rect RectFbg 12 0.002 0 st4 14139 643 h 1418 681 25 6.0 0 0.004 st3 29658 1348 Rect RectFbg 12 0.004 0 st3 14139 643 h 1418 681 25 2.5 0 0.002 st2 29658 1348 Rect RectFbg 12 0.002 0 st8 9262 421 h 929 697 16 14.0 0.000 0.012 st7 18038 820 Rect RectFbg 12 0.013 0 SO 6478 294 h 650 557 14 5.0 -0.001 0.002 st8 11959 544 Rect RectFbg 12 0.003 0 st10 6077 276 h 610 610 12 4.5 0.001 0.004 st9 11224 510 Rect RectFbg 12 0.004 0 st13 4401 200 h 441 662 18 11.5 0.001 0.016 st12 7111 323 Rect RectFbg 12 0.015 0 sit 2507 114 h 251 503 6 12.5 -0.001 0.011 st13 3799 173 Rect RectFbg 1 12 0.012 0 2016-Apr-21 12:04:04 wrightSOft• RlghtSuite®Uniwma12017 17.0.03 RSU16998 Page 2 ...Ice 29DO Industrial 33 rd StreetFort Pierce.tup Cale = RTS Fmrd Dwrfaces: SE Return Branch Details Duct Name HtgLoad HtgAVF Dsn AVF Veloc Wdth Length F.Loss Tot.Loss (Btuh) (cfm) (cfm) (fpm) (in) (ft) (in H2O) (in H2O) Parent Trunk Name ClgLoad CIgAVF Shape Matl Hght S.Loss Aj+Vav Cum.Loss . (Btuh) (cfm) (in) (in H2O) (in H2O) (in H2O) rb1 15952 725 c 1600 686 28 1.0 0.043 0.043 34400 1564 Rect VinIFIx 12 0.001 0 0.043 2016Apr-21 12:04:04 wrightsoft• RightSuge® Unix rsa12017 17.0.03 RSU16998 Page 3 ...Ice 2900 ]ndustriat 33 rd Str tFott Pi e.mp Calc = RTS Front D= faces: SE