Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCERECEI'D ]AN 2 0 2016 • a Planning & Development Services Department SCANNED Building & Code Regulations Division BY 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1.9%• Lucie County Certification for Design Load Compliance Project Name: Harbor Ridge Sales Center, Harbour Ridge Yacht & Country Club Project Address: 13396 Gilson Road, Palm City, FL Permit#: 151 1j—D_1 I q Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed _Partially Enclosed _Open 3. Risk Category: _I x II _III _ IV Exposure Category: x B _C _D 4. Design Wind Velocity 162 mph ASD x LRFD End Zone Width: 3'-2 ft 5. Mean Roof Height 141-4" ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 28.4 Zone 2: 33.2 Zone 3: 33.2 Zone 4: 29.2 Zone 5: 34.9 Garage: 29.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. -Design Sail Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: - I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: ����+" Mot#,,q� Wenjt �.o' * a�� ',., 5454 , Print Na v.�'a . o�� - �Gn i, de , Co.ICertlAut o ' Signature, Date, and Seal RGD CotQ;Cg,� own Rd, Suite 104, Jupiter, FL 33458 Compar ','i4inu.... . Revised 07/25/2014 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Harbour Ridge Sales Center, Harbour Ridge Yacht & Country Club Project Address: 126000 Harbour Ridge Blvd., Palm City, FL 34990 Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X 11 _III —IV Exposure Category: x B _C _D 4. Design Wind Velocity 162 mph X ASO _LRFD End Zone Width: 3'_2• ft S. Mean Roof Height 9'-8" ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 28.4 Zone 2: 33.2 Zone 3: 33.2 Zone 4: 29.2 Zone 5: 34.9 Garage: 29.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,000 PSF Soil Test Reports Submitted? X Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depi ctec�ioa� U provide adequate resistance to the design forces specified: Signature, Date, and Seal Revised 07/25/2014 RE �'�''-D JAN 2 0 2016 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 Certification for Design Load Compliance Project Name: Harbor Ridge Sales Center, Harbour Ridge Yacht & Country Club Project Address: 13396 Gilson Road, Palm City, FL Permit #: IS I I O I I Occupancy Type: Construction Type: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: X B _C _D 4. Design Wind Velocity 162 mph _ASD x LRFD End Zone Width: 3'-2" ft 5. Mean Roof Height 14'-4" ft Roof Pitch: 7 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 28.4 Zone 2: 33.2 Zone 3: 33.2 Zone 4: 29.2 Zone 5:34.9 Garage: 29.2 7. Design Loads: Floor: 250 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Went ua���''i 1 Y,''. — ert # 5454 Print Na � �:• •a LL 6;0 �'� Cert # & Co. Cert Auth. 'o W o2Q z ¢: m........,.0 _ —� • W N it F- Z Signature, Date, and Seal RGD Cor'� �� Z y F . own Rd, Suite 104, Jupiter, FL 33458 %� co COmpar ,',i,�'���i �rrjPO``�% Revised 07/25/2014