Loading...
HomeMy WebLinkAboutREVIEW COMMENTSf f PROPERTY INFORMATION Address: 13396 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel #: 4425-701-0016-00014 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0414 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS REVIEW COMMENTS SCANNED BY St. Lucie County Page 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tvve Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11/25/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404-A 11/25/2015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/25/2015 Comment: NEED SUB SUMMARY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1126/2016 1/26/2016 112612016 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 12/812015 121812015 Comment: APPROVED Jennifer Evans 121712015 1217/2015 COMPLETE Lashahna Ingram 11/25/2015 11/2512015 11125/2016 INCOMPLETE William Durden 112512016 • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. • SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. REVIEW COMMENTS z PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 1217/2015 Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014 THIS JOB REQUIRES SEPARATE SEX 12/7/2015 RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE FLORIDA ACCESSABILITY CODE 2014. 12/7/2015 Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND - SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. 12/7/2015 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 12/7/2015 Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015 PLANS EXAMINER REVIEW INCOMPLETE William Durden 121712015 Comment: - SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA 12/8/2015 PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. 12/812015 Comment: - SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. 12/8/2015 Comment: - ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. 1218/2015 Comment: - ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS INCORRECT. 12/8/2015 Comment: - SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS. PLEASE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. 1218/2015 Comment: - PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: - PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12/8/2015 APPROVED BYTHE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA - ADMINISTRATIVE CODE 1218/2015 Comment: - PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. 1218/2015 Comment: - PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. 1218/2015 Comment: - PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 1218/2015 Comment: - PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. 1218/2015 Comment: - GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. 1218/2015 Comment: - ENERGY CALC CALLS OUT FOR R30 BATT INSULATION, PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. 1218/2015 Comment: - PLANS CALL OUT 518 CDX PLYWOOD ROOF SHEETING, ENERGY CALC'S CALL OUT FOR 3/4 CDX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. 1219/2015 Comment: PLEASE SUBMIT LIFE SAFTY PLANS. ZONING REVIEW INCOMPLETE Jeffrey Johnson 121312015 121312015 Comment: A BOUNDARYAND TOPOGRAPHIC SURVEY IS REQUIRED TO THAT SHOWS THE PROPOSED BUILDING IMPROVEMENT ON THE PROPERTY. THE SURVEY SHOULD SHOW ALL BUILDING SETBACKS TO/FROM 12/4/2015 PROPERTY LINES AND THE PROPOSED FINISHED FLOOR ELEVATION. PROVIDE AN ELEVATION AT THE CROWN OF THE ROAD. THE FINISH FLOOR ELEVATION MUST BE A MINIMUM OF 181, ABOVE THE CROWN OF THE ROAD (GILSON ROAD). Address: City / State / Zip: Parcel #: 13396 Gilson Rd Palm City, FI 34990 4425-701-0016-000/4 SCANNED REVIEW COMMENTS --J-By- —_-- St. Lucie County t,7 Page 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: APPLICATION INFORMATION Permit Number: 1511-0414 Stories: Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Block: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tvpe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahnaingram 11125/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404-A 11/25/2015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11125/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/25/2015 Comment: NEED SUB SUMMARY ENGINEERING DEPARTMENT PENDING Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 12/7/2015 12/712015 Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 11/2512016 11/2512015 11125/2015 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride - 12/8/2015 Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND.UNIT,LIGHT AND RECP.NEEDED AT AIR HANDLER 121812015 UNIT,EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR,WALTER PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Kevin Singley 12/7/2015 1218/2015 Comment: M0.1 NOTE 3 TYPE "L" COPPER IS NOT TO BE USED AS REFRIGERANT PIPING. CHANGE TO "ARC". Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772(462-6443 PROPERTY INFORMATION Address: 13396 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel M 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0414 F�pj er'L Oftol Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc 7 Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS e REVIEW COMMENTS SCANNED BY St. Lucie County 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Type Status Reviewed By Date Staked Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11/25/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404-A 11/2512015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/25/2015 Comment: NEED SUB SUMMARY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1126/2016 1/2612016 1/26/2016 Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 1217/2015 121712015 Comment: FIRE DEPARTMENT REVIEW PENDING Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 1112512015 11/26/2015 11/25/2015 Comment: PE REVIEW COMMENTS (2) COMPLETE William Durden 1/25/2016 21412016 2J412016 Comment: N. Planning BDevelopment Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 Page 2 PE REVIEW COMMENTS (3) INCOMPLETE William Durden 21412016 Comment: • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA 1218/2015 PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 563.482 OF THE FLORIDA STATUTES. PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 121812015 1/26/2016 1/26/2016 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 121712015 1/25/2016 1/25/2016 Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 121712015 1/27/2016 112MO16 Comment: PLANS EXAMINER REVIEW COMPLETE William Durden 1217/2015 1/25/2016 1/25/2016 Comment: ZONING REVIEW COMPLETE Jeffrey Johnson 1213/2015 1213/2015 1213/2015 Comment: --- — � - - �- �- � REVIEW COMMENTS �eAiV►VEb-"'_-.. _ BY 't- Lucie County Page I PROPERTY INFORMATION Address: 13396 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel #: 4425-701-0016-000/4 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: APPLICATION INFORMATION Permit Number: 1511-0414 Stories: Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State I Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Block: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tvpe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11/25/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404-A 11125/2015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/25/2015 Comment: NEED SUB SUMMARY ENGINEERING DEPARTMENT COMPLETE Jeffrey Johnson 1/26/2016 1/2612016 1/26/2016 Comment: ENVIRONMENTAL REVIEW Comment: FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 12/8/2015 APPROVED Jennifer Evans PENDING COMPLETE Lashahna Ingram 11/2512015 12/7/2015 1217/2015 11125/2015 11/2512015 INCOMPLETE William Durden 1125/2016 • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. REVIEW COMMENTS -- Page 2 12/8/2015 Comment: • SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. 12/8/2015 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12/8/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G1530.005 OF THE FLORIDA ADMINISTRATIVE CODE 12/812015 Comment: • PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 12/8/2015 Comment: • PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 12JS12015 1/26/2016 1/2612016 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 12/7/2015 1/2512016 1/25/2016 Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 12J712015 1/27/2016 1/27/2016 Comment: PLANS EXAMINER REVIEW COMPLETE William Durden 12/7/2015 1/2512016 112512016 Comment: ZONING REVIEW COMPLETE Jeffrey Johnson 12I312015 12/3/2015 1213/2015 Comment: Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fart Pierce, FL 34982 Phone:(772)462.2172 Fax:(772(462.6443 PROPERTYINFORMATION Address: 13396 Gilson Rd City I State / Zip: Palm City, FI 34990 Parcel#: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0414 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Lie Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS SCANNED REVIEW COMMENTS BY St. Lucie County Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tvoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11/25/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404- A 11125/2015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/2512015 Comment: NEED SUB SUMMARY 12/2I2015 Comment: NEW SIGNATURE PAGE WITH MR TOLLIVER'S SIGNATURE ON BOTH SIDES. ENGINEERING DEPARTMENT PENDING Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 1217/2015 12/7/2015 Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 11/2512016 11/25/2015 11/25/2016 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 12/8/2015 Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND.UNIT,LIGHT AND RECP.NEEDED AT AIR HANDLER 12/8/2015 UNIT,EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR,WALTER PRIDE SR. Vic, �%rf/io. �asrn� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 349BZ Phone:(772)462.2172 Fax:(772)4625443 REVIEW COMMENTS ru�na oniunmorc mecrwn�cAL inwmrLe i t Kevin Singley 1217/2015 12/8/2015 Comment: MOA NOTE 3 TYPE "L' COPPER IS NOT TO BE USED AS REFRIGERANT PIPING. CHANGE TO "ARC". PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 1217/20115 Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014 THIS JOB REQUIRES SEPARATE SEX 12/7/2015 RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE FLORIDA ACCESSABILITY CODE 2014. 1217/2015 Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. 12l712015 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 12/712015 Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015 PLANS EXAMINER REVIEW INCOMPLETE William Durden 12I7/2015 Comment: • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA 1218/2015 PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. 12/8/2015 Comment: • SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. 12/8I2015 Comment: - ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. 12/8/2015 Comment: • ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS INCORRECT. 12/8/2015 Comment: - SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS, PLEASE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. 1218/2015 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12/8/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 121812015 Comment: • PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. 12/812015 Comment: • PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. 12/8/2015 Comment: • PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 12/8/2015 Comment: • PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. 12/8/2015 Comment: • GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. 12I0/2015 Comment: • ENERGY CALC CALLS OUT FOR R30 BATT INSULATION, PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. 1202015 Comment: • PLANS CALL OUT 518 COX PLYWOOD ROOF SHEETING, ENERGY CALC'S CALL OUT FOR 314 COX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. 121g12015 Comment: PLEASE SUBMIT LIFE SAFTY PLANS. ZONING REVIEW INCOMPLETE Jeffrey Johnson 121312015 1213/2015 Comment: A BOUNDARY AND TOPOGRAPHIC SURVEY IS REQUIRED TO THAT SHOWS THE PROPOSED BUILDING IMPROVEMENT ON THE PROPERTY. THE SURVEY SHOULD SHOW ALL BUILDING SETBACKS TO/FROM 1214/2015 PROPERTY LINES AND THE PROPOSED FINISHED FLOOR ELEVATION. PROVIDE AN ELEVATION AT THE CROWN OF THE ROAD. THE FINISH FLOOR ELEVATION MUST BE A MINIMUM OF 18" ABOVE THE CROWN OF THE ROAD (GILSON ROAD). Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(7'72)462.2172 Fax:(772)462-6443 REVIEW COMMENTS SCANN+ BY St. Lucie r 1 Address: 13396 Gilson Rd Owner(s): Harbour Ridge Country Club Inc City I State / Zip: Palm City, FI 34990 Parcel #: 4425-701-0016-600/4 Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: Block: APPLICATION INFORMATION Permit Number: 1511-0414 Stories: Automatic Sprinkler System? No Permit Type: BUILDING COMMERCIAL .Q CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Fax Number: 772-234-8188 Business Name: Proctor Construction Company, Uc Business Addr: 2050 Us Hwy 1, Ste 200 Email: Dtolliver@Proctorcc.Com City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS Review Typg Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11125/2015 Comment: NEEDS NOC Comment: NO VEG PERMIT UNDER THIS PERMIT PER DANA IN ERD FEES ATTACHED TO PERMIT 1511-0404- A 11/25/2015 HUMPHREY NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/2512015 Comment: NEED SUB SUMMARY ENGINEERING DEPARTMENT PENDING Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 12/8/2015 1218I2015 Comment: APPROVED Jennifer Evans 1217/2015 1217/2015 COMPLETE Lashahna Ingram 1112512015 11/2512015 11/2512015 INCOMPLETE William Durden 1/25/2016 • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. • SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. 3?��Oe4�1 c Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6"3 REVIEW COMMENTS 3 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA 12/8/2015 BUILDING CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12/812015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G1530.005 OF THE FLORIDA ADMINISTRATIVE CODE Comment: • PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING 12/812016 COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 121812015 Comment: • PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 1218/2015 Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND.UNIT,LIGHT AND RECP.NEEDED AT AIR HANDLER 1218/2016 UNIT,EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR,WALTER PRIDE SR. PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 1217/2015 1/2612016 1/25/2016 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Comment: 12I712015 1217/2015 Comment: 121712015 Comment: Greg Smyth 1217/2015 PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014 THIS JOB REQUIRES SEPARATE SEX RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE FLORIDA ACCESSABILITY CODE 2014. PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 12/712016 Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015 PLANS EXAMINER REVIEW COMPLETE William Durden 1217/2015 1/2512016 112512016 Comment: ZONING REVIEW INCOMPLETE Jeffrey Johnson 121312015 12/3/2015 Comment: A BOUNDARYAND TOPOGRAPHIC SURVEY IS REQUIRED TO THAT SHOWS THE PROPOSED BUILDING IMPROVEMENT ON THE PROPERTY. THE SURVEY SHOULD SHOW ALL BUILDING SETBACKS TO/FROM 12/4/2015 PROPERTY LINES AND THE PROPOSED FINISHED FLOOR ELEVATION. PROVIDE AN ELEVATION AT THE CROWN OF THE ROAD. THE FINISH FLOOR ELEVATION MUST BE A MINIMUM OF 18" ABOVE THE CROWN OF THE ROAD (GILSON ROAD). I Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)4624172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 13396 Gilson Rd City / State / Zip: Palm City, FI 34990 Parcel #: 4425-701-0016-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 1511-0414 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Donald L Tolliver Business Name: Proctor Construction Company, Llc Business Addr: 2050 Us Hwy 1, Ste 200 City / State / Zip: Vero Beach, FI 32960 REVIEWS AND COMMENTS SCANNED REVIEW COMMENTS BY St. Lucie County 1 Owner(s): Harbour Ridge Country Club Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-234-8188 Email: Dtolliver@Proctorcc.Com Review Tyg_e Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 11125/2015 Comment: NEEDS NOC 11/25/2015 Comment: NEEDS VEG REMOVAL PERMIT 11/25/2015 Comment: NEEDS ALL SUBS AGREEEMENTS 11/2512015 Comment: NEED SUB SUMMARY 1212/2016 Comment: NEW SIGNATURE PAGE WITH MR TOLLIVER'S SIGNATURE ON BOTH SIDES. ENGINEERING DEPARTMENT PENDING Comment: ENVIRONMENTAL REVIEW APPROVED Jennifer Evans 12f7/2015 12012015 Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 11/2512015 11/25/2015 11/25/2015 Comment: PLANS EXAMINER ELECTRIC PENDING Walter Pride Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Kevin Singley 12f7/2015 12/8/2015 Comment: MOA NOTE 3 TYPE "L" COPPER IS NOT TO BE USED AS REFRIGERANT PIPING. CHANGE TO "ARC". O Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)4624M REVIEW COMMENTS 2 --_.__--- _....._... __... _..... ........... �..,� wreu amym 7ZI7/2015 Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014 THIS JOB REQUIRES SEPARATE SEX 1217/2015 RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE FLORIDA ACCESSABILITY CODE 2014. 121712015 Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. 1277/2015 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 1217/2015 Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015 PLANS EXAMINER REVIEW INCOMPLETE William Durden 1217/2015 Comment: • SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA 12/8/2015 PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. 1218/2015 Comment: • SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. 12/812015 Comment: • ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. 1218/2015 Comment: • ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS INCORRECT. 12/8/2015 Comment: • SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS. PLEASE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. 1218/2015 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 1218/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G1530.005 OF THE FLORIDA ADMINISTRATIVE CODE 121812015 Comment: • PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. 12/8/2015 Comment: • PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. 12/8/2015 Comment: • PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 1218/2015 Comment: • PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE SO.O. 1218/2015 Comment: • GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. 12/812015 Comment: • ENERGY CALC CALLS OUT FOR R30 BATT INSULATION, PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. 12/8/2015 Comment: • PLANS CALL OUT 5/8 COX PLYWOOD ROOF SHEETING, ENERGY CALC'S CALL OUT FOR 3/4 COX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. ZONING REVIEW INCOMPLETE Jeffrey Johnson 12/312015 12/3/2015 Comment: A BOUNDARY AND TOPOGRAPHIC SURVEY IS REQUIRED TO THAT SHOWS THE PROPOSED BUILDING 1214/2015 IMPROVEMENT ON THE PROPERTY. THE SURVEY SHOULD SHOW ALL BUILDING SETBACKS TO/FROM PROPERTY LINES AND THE PROPOSED FINISHED FLOOR ELEVATION. PROVIDE AN ELEVATION AT THE CROWN OF THE ROAD. THE FINISH FLOOR ELEVATION MUST BEA MINIMUM OF 18. ABOVE THE CROWN OF THE ROAD (GILSON ROAD). w; Plarinlnysoeveioproentserylces: REVIEW COMMENTS :Building &Code. Regulation Dlvlslim 2300 VIrgINa Avenue, Fort Pierce, FL., 34982 , Phone.*ff72(462.2172 Fa%:(772)4676447 Page 2 121812016 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12/8/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 12/8/2015 Comment: • PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 LFORIDA ENERGY CODE. 12/8/2015 Comment: • PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE 50.0. PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 12/8/2015 1/26/2016 1/2612016 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 1217/2015 1/25/2016 1/25/2016 Comment: PLANS EXAMINER PLUMBIF(_ G,gj"y;,COMP.LETE".aI' _' - Gieg:Sinytti L1y712015 1Y27/20i6"s--1/2712016 Comment: PLANS EXAMINER REVIEW COMPLETE William Durden 1217/2015 1/25/2016 1/2512016 Comment: ZONING REVIEW COMPLETE Jeffrey Johnson 1213/2015 1213/2015 121312015 Comment: r i 0 2016 SCANNED BY St. Lucie County -� January 8, 2016 PEACOCK + LEWIS Saint Lucie County Architects and Planners, LLC Planning & Development Services Lk. # AAC 000020 Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 1293 US Highway one Re: Harbor Ridge Sales Center (14-106) Permit # 1511-0414 North Palm Beach, FL 33408 Pursuant to the planning comments regarding the proposed renovations at Harbor Ridge T: 5 61.6 2 6.9 7 0 4 Sales Center located at 13396 Gilson Road, Palm City, I am writing to clarify the issues raised F: 561.626.9719 in the responses received. REVIEW and COMMENTS: 1610 Trade Center Way Suite #5 Naples, Fl, 34109 Plans Examiner Electric T: 239.631.2332 1. Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND. UNIT, LIGHT F: 239.300.6402 AND RECP. NEEDED AT AIR HANDLER UNIT, EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR, WALTER PRIDE SR. Response: WP receptacle has been added at condensing unit. Light and Architecture receptacle have been added at AHU. Both exit signs have been added. See revised E0.1. Planning Plans Examiner Mechanical I.Comment: MO.1 NOTE 3 TYPE "L" COPPER IS NOT TO BE USED AS Interior Design REFRIGEERANT PIPING. CHANGE TO "ARC' Response: General note #23 was revised to now specify ACR type copper Programming tubing for the refrigerant lines. Graphic Design 2. Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014, THIS JOB REQUIRES SEPARATE SEX RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE Project Delivery FLORIDA ACCESSABILITY CODE 2014.2 Response: Per section 403.2 of the Florida plumbing code 2014, exception 2. Separate facilities are not required in a structure with an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air Member A I A conditioned occupancy of 1,282 GSR The occupant load of the building is 13 people. www.peacockandIewis.com 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 2 - Janu ,,3, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 3. Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. Response: Per table 403.1 drinking fountains are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 4. Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014. Response: Per table 403.1 service sinks are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 5. Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015. Response: Separate shutoff valve for wall hydrant is located in cabinet beneath sink. Please refer to View 1 "Domestic Water Floor Plan" on sheet P1.1. Shutoff valve is labeled on plan as isolation valve. Plans Examiner Review 1. Comment: SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. Response: Shall comply 2. Comment: SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE. PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. Response: Shall comply 3. Comment: ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. Response: Shall provide additional copy 14-106 Hubor Ridge Sales Center Permit Response 01.08.16 Page 3 - jam ,8, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 4. Comment: ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS INCORRECT. Response: Updated certificate attached. 5. Comment: SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS. PLEAE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. Response: Shall comply 6. Comment: PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Response: To be provided by truss manufacturer 7. Comment: PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15- 30.005 OF THE FLORIDA ADMINISTRATIVE CODE. Response: To be provided by truss manufacturer 8. Comment: PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. Response: See A-701 for window details. 9. Comment: PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. Response: See wall types and partition schedule for interior wall finishes, painted gyp bd. Floor finishes, by others to meet class 'A'. Carpet typical, porcelain tile at restrooms. 10. Comment: PLEAE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 FLORIDA ENERGY CODE. Response: General contractor to submit product data to comply. 11. Comment: PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. Response: General contractor to submit soils report for review. 12. Comment: GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. Response: The two glazed doors are included on page 4 of the input data report in the window section. They are included in the window section because the door is more than 50% glazed. 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 4 - jam, `8, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 13. Comment: ENERGY CALC CALLS OUT FOR R30 BATT INSULATION. PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. Response: Wall sections 1,2,3,4,5 and 6/A-301 show R-30 top chord insulation. 14. Comment: PLEASE CALL OUT 5/8 CDX PLYWOOD ROOF SHEETING. ENERGY CALC'S CALL OUT FOR 3/4 CDX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. Response: Will comply 15. Comment: PLEASE SUBMIT LIFE SAFTY PLANS. Response: Life Safety plans attached for review. 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 r -I PEACOCK + LEWIS Architects and Planners, LLC Lic. # AAC 000020 1295 US Highway One North Palm Beach, FL 33408 T: 561.626.9704 F: 561.626.9719 SCANNED BY St. Lucie County 8, 2016 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Re: Harbor Ridge Sales Center (14-106) Permit # 1511-0414 RECEP"D JAN 2 0 2016 Pursuant to the planning comments regarding the proposed renovations at Harbor Ridge Sales Center located at 13396 Gilson Road, Palm City, I am writing to clarify the issues raised in the responses received. REVIEW and COMMENTS: 1610 Trade Center Way Suite #5 Naples, FL 34109 Plans Examiner Electric T: 239.631.2332 1. Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND. UNIT, LIGHT F: 239.300.6402 AND RECP. NEEDED AT AIR HANDLER UNIT, EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR, WALTER PRIDE SR. Response: WP receptacle has been added at condensing unit. Light and Architecture receptacle have been added at AHU. Both exit signs have been added. See revised E0.1. Planning Plans Examiner Mechanical 1. Comment: MO.1 NOTE 3 TYPE "LP COPPER IS NOT TO BE USED AS Interior Design REFRIGEERANT PIPING. CHANGE TO "ARC" Response: General note #23 was revised to now specify ACR type copper Programming tubing for the refrigerant lines. Graphic Design 2. Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014, THIS JOB REQUIRES SEPARATE SEX RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE Project Delivery FLORIDA ACCESSABILITY CODE 2014.2 Response: Per section 403.2 of the Florida plumbing code 2014, exception 2. Separate facilities are not required in a structure with an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air Member A I A conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. www.peacockandlewis.com 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 2 - Janu , . �3, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 3. Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. Response: Per table 403.1 drinking fountains are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 4. Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014. Response: Per table 403.1 service sinks are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 5. Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015. Response: Separate shutoff valve for wall hydrant is located in cabinet beneath sink. Please refer to View 1 "Domestic Water Floor Plan" on sheet P1.1. Shutoff valve is labeled on plan as isolation valve. Plans Examiner Review 1. Comment: SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. Response: Shall comply 2. Comment: SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE. PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. Response: Shall comply 3. Comment: ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. Response: Shall provide additional copy 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 3 - Jant., , 8, 2016 + Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 4. Comment: ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS INCORRECT. Response: Updated certificate attached. 5. Comment: SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS. PLEAE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. Response: Shall comply 6. Comment: PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Response: To be provided by truss manufacturer 7. Comment: PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15- 30.005 OF THE FLORIDA ADMINISTRATIVE CODE. Response: To be provided by truss manufacturer 8. Comment: PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. Response: See A-701 for window details. 9. Comment: PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. Response: See wall types and partition schedule for interior wall finishes, painted gyp bd. Floor finishes, by others to meet class 'A'. Carpet typical, porcelain We at restrooms. 10. Comment: PLEAE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 FLORIDA ENERGY CODE. Response: General contractor to submit product data to comply. 11. Comment: PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE 50.0. Response: General contractor to submit soils report for review. 12. Comment: GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. Response: The two glazed doors are included on page 4 of the input data report in the window section. They are included in the window section because the door is more than 50% glazed. 14-106 Harbor Ridge Sales Center Pemut Response 01.08.16 Page 4 - Jam'_ )8, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 13. Comment: ENERGY CALC CALLS OUT FOR R30 BATT INSULATION. PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. Response: Wall sections 1,2,3,4,5 and 6/A-301 show R-30 top chord insulation. 14. Comment: PLEASE CALL OUT 5/8 CDX PLYWOOD ROOF SHEETING. ENERGY CALC'S CALL OUT FOR 1/4 CDX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. Response: Will comply 15. Comment: PLEASE SUBMIT LIFE SAFTY PLANS. Response: Life Safety plans attached for review. 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 PEACOCK + LEWIS Architects and Planners, LLC Lic. # AAC 000020 1295 US Highway One North Palm Beach, FL 33408 T: 561.626.9704 F: 561.626.9719 1610 Trade Center Way Suite #5 Naples, FL 34109 T: 239.631.2332 F: 239.300.6402 Architecture Planning Interior Design Programming Graphic Design Project Delivery Member AIA RLCci.' .0 JAN 202016 8, 2016 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Re: Harbor Ridge Sales Center (14-106) Permit # 1511-0414 SCANNED BY St. Lucie County Pursuant to the planning comments regarding the proposed renovations at Harbor Ridge Sales Center located at 13396 Gilson Road, Palm City, I am writing to clarify the issues raised in the responses received. REVIEW and COMMENTS: Plans Examiner Electric 1. Comment: WEATHER PROOF RECP. NEEDED AT A.C.COND. UNIT, LIGHT AND RECP. NEEDED AT AIR HANDLER UNIT, EXIT SIGN NEEDED AT BACK DOOR AND DOOR LEADING TO OFFICE AT BACK DOOR, WALTER PRIDE SR. Response: WP receptacle has been added at condensing unit. Light and receptacle have been added at AHU. Both exit signs have been added. See revised E0.1. Plans Examiner Mechanical 1. Comment: MO.1 NOTE 3 TYPE " L' COPPER IS NOT TO BE USED AS REFRIGEERANT PIPING. CHANGE TO "ARC' Response: General note #23 was revised to now specify ACR type copper tubing for the refrigerant lines. 2. Comment: PER SECTION 403.2 OF THE FLORIDA PLUMBING CODE 2014, THIS JOB REQUIRES SEPARATE SEX RESTROOMS WHICH MUST MEET THE ADA REQUIREMENTS OF SECTION 213 OF THE FLORIDA ACCESSABILITY CODE 2014.2 Response: Per section 403.2 of the Florida plumbing code 2014, exception 2. Separate facilities are not required in a structure with an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. www.peacockandIewis.com 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 2 - jam '8, 2016 Harbor Ridge z>aies Center Permit Responses Peacock + Lewis No.14-106 3. Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014 AND SECTION 211 OF THE 2014 FLORIDA ACCESSABILITY CODE. Response: Per table 403.1 drinking fountains are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 4. Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014. Response: Per table 403.1 service sinks are not required for an occupant load of 15 or fewer. The Code analysis sheet incorrectly identifies the occupant load based on the total building area (including covered entries. The occupant load shall be based on the air conditioned occupancy of 1,282 GSF. The occupant load of the building is 13 people. 5. Comment: PLEASE SHOW SEPARATE SHUTOFF VALVE FOR WALL HYDRANT PER SECTION 606.2 OF THE FLORIDA PLUMBING CODE 2015. Response: Separate shutoff valve for wall hydrant is located in cabinet beneath sink. Please refer to View 1 "Domestic Water Floor Plan" on sheet P1.1. Shutoff valve is labeled on plan as isolation valve. Plans Examiner Review 1. Comment: SUBMIT THE PRODUCT APPROVAL, OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.482 OF THE FLORIDA STATUTES. Response: Shall comply 2. Comment: SUBMITTED PLANS DO NOT HAVE ORIGINAL SIGNATURE. PLEASE SUBMIT PLANS WITH ORIGINAL SIGNATURES. CHAPTER 107 OF THE 2014 FLORIDA BUILDING CODE. Response: Shall comply 3. Comment: ONLY ONE CERTIFICATE FOR DESIGN LOAD COMPLIANCE WAS SUBMITTED. Response: Shall provide additional copy 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 3 - jam' '8, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 4. Comment: ADDRESS ON CERTIFICATE FOR DESIGN LOAD COMPLLANCE IS INCORRECT. Response: Updated certificate attached. 5. Comment: SUBMIT 3 SETS OF PLANS AND 2 ELECTRONIC SETS OF DOCUMENTS. PLEAE SEE ST. LUCIE COUNTY COMMERCIAL BUILDING PERMIT CHECKLIST. Response: Shall comply 6. Comment: PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Response: To be provided by truss manufacturer 7. Comment: PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15- 30.005 OF THE FLORIDA ADMINISTRATIVE CODE. Response: To be provided by truss manufacturer 8. Comment: PLEASE FURNISH WINDOW FLASHING DETAIL ON PLANS PER CHAPTER 1405.4 OF THE FLORIDA BUILDING CODE. Response: See A-701 for window details. 9. Comment: PLEASE PUT ON PLANS SMOKE DEVELOPMENT AND FLAME SPREAD FOR INTERIOR FINISHES. SEE CHAPTER 803 OF THE 2014 FLORIDA BUILDING CODE. Response: See wall types and partition schedule for interior wall finishes, painted gyp bd. Floor finishes, by others to meet class 'A'. Carpet typical, porcelain We at restrooms. 10. Comment: PLEAE SUBMIT THE ENERGY PERFORMANCE SHEETS FOR ALL GLAZED OPENINGS SHOWING COMPLIANCE WITH CHAPTER 402 OF THE 2014 FLORIDA ENERGY CODE. Response: General contractor to submit product data to comply. 11. Comment: PLEASE SUBMIT SOIL REPORT. SEE CONSTRUCTION NOTES ON PAGE S0.0. Response: General contractor to submit soils report for review. 12. Comment: GLAZED DOORS ARE NOT ON THE ENERGY CALC'S. Response: The two glazed doors are included on page 4 of the input data report in the window section. They are included in the window section because the door is more than 50% glazed. 14-106 Harbor Ridge Sales Center Permit Response 01.08.16 Page 4 - Jani _ 8, 2016 Harbor Ridge Sales Center Permit Responses Peacock + Lewis No.14-106 13. Comment: ENERGY CALC CALLS OUT FOR R30 BATT INSULATION. PLANS CALL OUT R30 SPRAY INSULATION. PLEASE CORRECT. Response: Wall sections 1,2,3,4,5 and 6/A-301 show R-30 top chord insulation. 14. Comment: PLEASE CALL OUT 5/8 CDX PLYWOOD ROOF SHEETING. ENERGY CALC'S CALL OUT FOR 3/4 CDX ROOF SHEETING UNDER ROOF SECTION OF THE ENERGY CALC'S. PLEASE CORRECT. Response: Will comply 15. Comment: PLEASE SUBMIT LIFE SAFTY PLANS. Response: Life Safety plans attached for review. 14-106 Huber Ridge Sales Center Permit Response 01.08.16