Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSRECENT 0 MAR 0 7 2016 DATE: 2/24116 p� ENGINEERING & INC. Phone: (866) 781-6889 •Fax: (866)'784-8550 www.floiridaengineeringandtesting.com 250 S.W.13t6 Avcnue Pompano Beach, FL 33069 JOB ORDER #: 16-629 CLIENT: CP Rankin Inc. ADDRESS: 4359 County Line Road Chalfont, PA 18914 PROJECT: Advanced Auto Parts # 9507 22 Ga. Steel Insulated Roof Deck ADDRESS: 353E Prima Vista Blvd. Port Saint Lucie, FL FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: ALF Height = 20' Max. Exposure: C Basic/lAtimat t Pphy Length= 104' Category: II Nominal Wind Speed: V�d=V it*40.6 Width = 63' Slope: < 7' (asd = allowable strength design) Parapet Wall: < 3' Commercial KZ = 0.90, Kzt =1.0, Kd ST. LUCIE COII{EIY CONCEALED FASTENERS OR ATTACHIX M A Z Design Calculations: ARETHERSPONSIBUNOFTHE , Velocity Pressure: q = 0.00256*KzK�tKdV2COMMCTOR OFRECORD' Velocity Pressure (,dt): q=0.00256(0.90)(1.0)(0.85)(170)z] = 56.60 psf Velocity Pressure (mod): q=0.00256(0.90)(1.0)(0.85)(170*40.6)21= 33.96 psf Width of Pressure Coefficient: 0.1(63') = 6.3' 0.4(20') = 8.(' ) use: 6'6" Effective Wind Area: <1 Oft For parapet height three feet (T) or larger, zone three (3) shall be treated as External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 BLDG: ELEC: DATE: DATE. MECH: DATE. Internal Pressure Coefficient: 1) GCP; = 0.18 THESE PLANS AND All PROPM'WRK ARE GUN C1' PO MY CMEC31Or'SI REG1U43ED Flk� IR�CYOAS ifl9i MAM RECGBMW IN ORDER TO a ` OOMPLYTurd ALL Ar"'Pi Qrra7ily �{� A�►� Assurance 4 Page 2, 2/24/16, Job Order # 16-629 • CP Rankin, Inc. Advanced Auto Parts # 9507 - 22 Ga. Steel Insulated Roof Deck 353 E. Prima Vista Blvd.; Port Saint Lucie, FL: Design Pressures Based on Vasa: 1) Field P1 = 33.96*[(-1.0) — (0.18)] = -40.1 psf 2) Perimeter P2 = 33.96*[(-1.8) — (0.18)] = -67.2 psf 3) Corners P3 = 33.96* [(-2.8) — (0.18)] = -101.2 psf Attachment Requirements Per RAS-117: FLO A Based on the requirements of Notice of Acceptance # 13-1212.04 pg 52 of 89, System Type C(28), with a maximum design pressure-45psf, the following are our recommended patterns for fastening minimum 0.5" thick ISO 95+ GL, RESISTA, ISOGARD HD insulation layer to the minimum 22 ga. steel deck with supports spaced maximum 6 ft. o.c. (with a MCRF of 3601bf) with approved Firestone Heavy -Duty # 15 fasteners and UltraPly TPO InvisiWeld Plates: Fasteners Per Board(Minimum) Insulation Board Field Perimeter Corners 4' x 4' 4 6 9 4'x8' 8 12 18 Notes: Corners and perimeter area dimension shall not be less than a = 66" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications Sincerely, -ILE { ,. .a P P.E.Mark A. Mesiaho, Florida Engineering & Testing, Inc. Florida Reg. No. 48202 Certificate of Authorization No. 6923