HomeMy WebLinkAboutINSULATION PAPPERSRECEIVED MAR 0:72016 SCANNED
SCANNED BY
BY Rentsed 6-I-06
St. Lucie County 't Lucie County
IIL CLASS A. B, C
SYSTEM: MECNANCiALLY ATTACHED
MEMBRANE: UltraPly TPO, UltraPly Platinum, RellexEON, ReflexEON Platinum
CONSTRUCTION: NEW, RETROFIT OR TEAR -OFF
Max Class Deck Insulation Assembly Remarks ULltem
Slope No.
3 A C,NC Deck I A,MA,69
Insulation: (opt) Firestone ISO 95+GL, any thickness
Coverboard: min. 1;4" DenwDeck, D-D Prime, IND DuraGuard
Membrane: Membrane: UltraPly TPO (45,60 or 80 mil), UltraPly
Platinum (80 mild ReflexEON (60 or 80 mil),
ReflexEONPlatinum (80 mil), mechanically attached
1-314 A NC Dark 1,2 A,MA,68
C(2) Insulation: (opt) Firestone ISO 95+ GL, any thickness
Coveiboard: nrin. UP' Firestone FberTop B, C, E or S
Membrane: Membrane: UltmPly TPO (45, 60 or 30 mil), UhraPly
Platinum (80 mil), ReflexEON (60 or 80 mil),
ReflexEON Platinum (80 mil), mechanically attached
lit A NC Deck: 1,2 A,MA,67
C(2) Insulation: Firestone ISO 95+G1., any thickness
Membrane: Membrane: UltmPly TPO (45, 60 or 80 mrl), U1tmPly
Platinum (80 mil), RcflexEON (60 or 80 mil),
ReflexEON Platinum (90 milj meebanically.attached
W A C - Deck: A,MA,75
SlipSheeC two ormomlayersofAtlas'T'R50"
Membrane: Membrane: UltraPly TPO (45,60 or 80 mil), UltraPly
Platinum (80 mil), ReflexEON (60 or 80 mil),
ReflexEON Platinum (80 mil), mechanically attached
I A C Deck: A,MA,88
Slip Sheet: two layers "VersaShield Underlayment" or
"VersaShield FB 2S"
Membrane: Membrane: UltmPly TPO (45, 60 or SO mil), UltraPly
Platinum (90 mil), ReflexEON (60 or 80 mil),
RellexEON Platinum (80 mil), mechanically attached
1/2 A C Deck: A,MA,89
Slip Sheet: two layers "VersaShield Underlayment" or
"VersaShield FB"2S"
Insulation: Firestone ISO 95+GL, any thickness
Mcmbmae: Membrane: 1.111r0P1y TPO (45,60 or 80 mil), UltmPly
Platinum (80 mil), ReflexEON (60 or 80 mil),
ReflexEON Platinum (00 mii), mechanically attached
FILE"' COPY
1) LS.0.FIX,LS.0.Spmy,LS.0. Twin Pack orhot asplstltmaytx used to attach insulation to deck andror inwlatiunminsuletimorcoverboards
and mamlain the above rating AtrxT Consult Pitustone't'srhnim]for acceptable combinations for Waamntypmposm
2) UL CIM111eadan on be maintained, at the slope indicated, overa combtutible deck by inaarpamtlag Sri" gypsomboard or 5:"Georgia-Paoifse
"Dcns.Dwk" dim dyoa Iheoombush'ble dmL-
"Tha above stated assendslles rinn, not be suitable fwa Firestone Red Shield Wananty. Cemmi Firestone Rooting Solutions Depathurnt, prior to
InstaOwlon, for appmral of=mablyfawmmntypurposee a
.L
Re%ised 64-06
UL CLASS A, B, C
SYSTEM: MECBANCLILLY ATTACID7D
MEMBRANE: UltraPly TPO, UltraPly Platinum, ReflaxEON, ReilexEON Platinum
CONSTRUCTION: NEW, RETROIT r OR TEAR -OFF
Alex Class Deck Insulation Assembly Remarks
Slope
U2 A C Deck:
Slip Sheet: two layers "VcrsaShieW FE-IS"
Insulation'. (opt)FirestoneJSO95+GI, any thickness
Membrane: Membrane; UltroPly TPO (45, 60 or 80 mil), U1tmPly
Platinum (80 mill), ReflaxBON (60 or 80 mil),
ReflexEON Platinum (80 mil), mechanically attached
I B C Dcck:
Base Sbect: one or more plies of Firestone MB Base M
Insulation:
a) min. 1.5' Firestone ISO 95+GL
b)min. 1"FiberTop BAB or S
c) min.1/2" FiberTop B,C,E or S over
min. 1" Firestone ISO 95+ GL
Membrane: Membrane: UitraPly TPO (45, 60 or 80 mi), UltraPly
Platinum (80 mil), RcflcxEON (60 or 80 mil),
ReflcxEON Platinum (80 mil), mechanically attached
B C Deck:
Insulation:
a) min. 1.5" FiberTop BCE or S
b) min.1/2" FibetTop B,C,E or S over
min. 1.5"Firestone ISO 95+01,
Membrane: Membrane: UltraPly TPO (45,60 or 80 mil), UltraPly
Platinum (80 mil), ReilexEON (60 or 80 mil),
ReflcaEON Platinum (80 col), mechanically attached
U2 B C Deck:
Slip Sheet: one or more layers of Atlas'FR 50"
Membrane: Membrane: UlimPlyTPO (45, 60 or SOmil), IlltraPly
Platinum (90 mil), RcllexEON (60 or 80 roil),
Renex)ION PIatinum (80 mil), mechanically attached
B C Deck:
Slip Shed: two layers "VersaShield Undcrlaymem" or
"VersaShield FB-2S", Preliminary attachment
Membrane: Membrane: UltmPly TPO (45, 60 or 80 mil), U1tmPly
Platinum (80 mil), ReflexEON (60 or 80 mil),
ReflexEON Platinum (90 miD, mechanically attached
UL Item
No.
A,MA,90
B,MA,06
B,AMO,
B,MA,05
B,MA,15
1) IS.O.FIX,I.SOSpmy,ISA. 71avin pack orhot aspball may be used to attach insulation to deck and'or insulation m insulation wcoverhoank
and nwimoin tho above mtingehonn. Conmlt Firestone TecludealroraccgMblemmbinatimsrwwotmntypurposes.
2) UL ClasslDsolon can be maintained, attheslope indimled. over a combustible deck by incorporating W'gpmmbwrd or!" GewgimPacifrc
"Ikns-Deck" directly on theeombusiNt deck.
w1he above stated assemblies may not be suitable foraFuestone Red Shield Warranty. Contact Firestonexoofmg Solutions Dep. mamt, priorta
installation, for approval ofasserovy fur Warranty pumses."
ti
Revised54•06
UL CLASS A, B, C
SYSTEM: MECHANCIALLY ATTACHED
MEMBRANE: UltraPly TPO, UltraPly Platinum, RellexLON, RcRexEON Platinum
CONSTRUCTION: RECOVER
Max Class Deck Insulation Assembly Remarks ULItem
Slope No.
1 ABC C Existing Roof System. Class A, B, or C BUR (smooth surface or cap MR, 01
sheet), to retain Existing Classification, cover with:
Slip Sheer. Atlas "FR IO" or "FR 11", one toyer
Membrane. Membrane: UitmPly TPO (45,60 or 80 teal), U1traPty
Platinum (80 mil), ReflexBON (60 or 80 mil),
ReflexEON Platinum (80 tail), mechanically attached
I ABC C Existing Roof System Class A, B, or C BUR (smooth surface or cap MR,02
sheet), to retain Existing Classification, cover with:
Slip Sheet: "VemaShield Underlaymcnt", one layer
Membrane: Membrane. UltraPly TPO (45, 60 or g0 rm`I), UltmPly
Platinum (80 mil), RcflexEON (60 or 80 mil),
ReflexBON Platinum (80 mil), mechanically attached
'I'he above stated assemblies may not be suitable faro Firestone Red Shield Wevmty.Cantact Fireaerc Roofing Solutions Depamnent, priorto
iastailatimforappeavai ofamenably fir warranty ympas .`
10