NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Firestone Building Products Company, LLC
250 West 96'h Street F" I LE. C Oft EP
Indianapolis, IN 46260
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner, the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Firestone UltraPly TPO & TPO XR Single Ply Roof Systems over Recover Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0425.05 and consists of pages 1 through 89.
The submitted documentation was reviewed by Jorge L. Acebo.
MIANI•DADECOUNrY
,.... r
NOA No.:134212.04
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 1 of 89
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub -Category: Single Ply Roofing
Material: TPO
Deck Type: Recover
Maximum Design Pressure: See specific deck type
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Dimensions
Specifications
Product Description
UltraPly TPO
Various
TAS 131
Reinforced TPO 0.045" to
ASTM D6878
0.080" thick membrane.
UltraPly TPO XR 100
Various
TAS 131
Reinforced TPO 0.045"
ASTM D6878
membrane with 8 oz. fleece
backing)
UltmPly TPO XR 115
Various
TAS 131
Reinforced TPO 0.060"
ASTM D6878
membrane with8 oz. fleece
backing
UltraPly TPO XR 135
Various
TAS 131
Reinforced TPO.080"
ASTM D6878
membrane with 8 oz. fleece
backing.
UltraPly TPO Reinforced
Various
TAS 131
TPO curb flashing
Curb Comer
ASTM D6818
UltraPly 18" Curb
Various
TAS 131
TPO curb flashing
Flashing
ASTM D6878
UltraPly TPO
Various
TAS 131
Molded TPO for comer flashing
Inside/Outside Comer
ASTM D6878
UltraPly TPO Large Pipe
Various
TAS 131
TPO flashing for large round
Flashing
ASTM D6878
penetrations
UltraPly TPO T-Joint
Various
TAS 131
TPO flashing for T joints
Cover
ASTM D6878
UltraPly TPO Penetration
Various
TAS 131
Penetration sealing kit for
Kit
ASTM D6878
UltraPly TPO
UltraPly TPO Walkway
Various
TAS 131
TPO walkway pad
Pad
ASTM D6878
UltraPly TPO Coated
Various
TAS 131
TPO laminated to hot -dipped
Metal
ASTM D6878
galvanized steel for flashing
U1tmPly TPO Premium
Various
TAS 131
TPO walkway pad
Walkway Pad
ASTM D6878
UltraPly TPO Reinforced
Various
TAS 131
TPO flashing for round
Split Pipe Boot
ASTM D6878
penetrations V to 9" in diameter
UltraPly TPO 8"
Various
TAS 131
8" wide 60 mil TPO cover strip
Reinforced Cover Strip
ASTM D6878
NOA No.:13-1212.04
M[AMI•DADE COUMTY
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 2 of 89
0
Product
UltraPly TPO Universal
Pipe Boot
UltraPly TPO
Unsupported Flashing
UltraPly QuickSeam
R.M.A. Strip
Single -Ply QuickPrime
Primer
XR Bonding Adhesive
UltraPly Bonding
Adhesive
XR Stick Membrane
Adhesive
I.S.O. Stick
I.S.O. Twin Pack
Insulation Adhesive
I.S.O. Fix II
Single -Ply LVOC
Bonding Adhesive
Single -Ply LVOC
Bonding Adhesive 1168
Water Based Bonding
Adhesive P
Dimensions
Various
Various
10" x 100'
1 gallon, 3 gallon
5 gal. pail
5 gal. pail
5 gal. pail
5 gal &
1500 ml
1500 ml
30 lbs.
5 gal. pail
5 gal. pail
5 gal. pail
Test
Specifications
Product Description
TAS 131
TPO flashing for round
ASTM D6878
penetrations I" to 6" in diameter
TAS 131
Unreinforced TPO used for
ASTM D6878
flashing
Proprietary
Strip of UltraPly TPO with
QuickSeam Tape for anchoring
membrane to substrate.
Proprietary
Primer for TPO Flashing.
Proprietary Solvent based adhesive.
Proprietary Solvent based adhesive.
Proprietary A low-rise polyurethane, low
VOC, membrane adhesive.
Proprietary A dual component polyurethane
adhesive.
Proprietary A dual component polyurethane
adhesive.
Proprietary A single component
polyurethane adhesive.
Proprietary Solvent based bonding adhesive.
Proprietary Solvent based bonding adhesive.
Proprietary Water based bonding adhesive.
NOA No.:13-1212.04
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 3 of 89
APPROVED INSULATIONS:
Product Name
ISO 95+ GL and tapered
ISOGARD HD
ISOGARD HD Composite
DensDeck, DensDeck Prime
RESISTA and tapered
SECUROCK Gypsum -Fiber
Roof Board
SECUROCK Glass -Mat
Roof Board
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate with a coated
fiberglass facer
Polyisocyanurate with a coated
fiberglass facer composite insulation.
Silicon treated gypsum
Polyisocyanurate foam core laminated
to a coated fiberglass facer.
Rigid, gypsum -based board stock
Rigid, gypsum -based board stock
Manufacturer
(With Current NOA)
Firestone Bldg. Products
Firestone Bldg. Products
Firestone Bldg. Products
Georgia Pacific Gypsum LLC
Firestone Bldg. Products
USG Corp.
USG Corp.
NOA No.: 134212.04
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 4 of 89
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With CurrentNOA)
1.
Firestone Heavy -Duty
#15 Fastener for steel,
N/A
Firestone Bldg. Products
Wood, concrete decks.
2.
Firestone All -Purpose
#14 Fastener for steel,
N/A
Firestone Bldg. Products
Wood, concrete decks.
3.
Firestone Pre -Assembled
#14 w/insulation plate for
N/A
Firestone Bldg. Products
Fastener & plate
steel, Wood, concrete
decks.
4.
Pre -Assembled Heavy
#15 w/insulation plate for
N/A
Firestone Bldg. Products
Duty Fastener & Plate
steel, Wood, concrete
decks.
5.
Firestone Heavy Duty Plus
Insulation and membrane
Various
Firestone Bldg. Products
fastener.
6.
Concrete Drive
Structural concrete
Various
Firestone Bldg. Products
fastener.
7.
Purlin Fasteners
#12 purlin fastener.
Various
Firestone Bldg. Products
8.
Insulation Fastening Plate
Galvalume insulation
3" diameter
Firestone Bldg. Products
plate.
9.
Firestone HD Plus Seam
Galvalume insulation
2%"
Firestone Bldg. Products
Plate
plate.
diameter
10.
Firestone HD Seam Plates
AZ55 or AZ50 galvalume
2-3/8"
Firestone Bldg. Products
insulation plate.
diameter
11.
Coiled Metal Batten Bar
Galvalume AZ55 batten
220' long, 1"
Firestone Bldg. Products
strip.
wide
12.
UltraPly TPO InvisiWeld
High-performance TPO
3" diameter
Firestone Bldg. Products
Plates
membrane fastening
system.
13.
Metal Batten Bar
Galvalume AZ55 batten
10' long, 1"
Firestone Bldg. Products
bar.
wide
14.
Firestone Polymer Batten
Polymer batten
250' long,
Firestone Bldg. Products
Strip
3/4" wide
15.
Firestone Coiled Metal
Galvalume AZ55 batten
220' long, 1"
Firestone Bldg. Products
Batten Strip
strip.
wide
NOA No.:13-1212.04
MIAMI•DADECOUNW Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 5 of 89
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Description
Date
Underwriters Laboratories Inc.
R9516
UL 790
10/29/13
Factory Mutual Research
3032272
FM 4470
05/22/09
Corporation
3036642
FM 4470
10/09/09
3030650
FM 4470
07/10/09
3035560
FM 4470
01/11/10
3019991
FM 4470
09/20/05
3017120
FM 4470
04/30/04
3038546
FM 4470
12/17/10
3039133
FM 4470
04/07/11
3036747
FM 4470
02/12/10
3040535
FM 4470
10/05/10
3035017
FM 4470
04/15/09
3038191
FM 4470
08/04/11
3036256
FM 4470
04/27/09
3038546
FM 4470
12/17/10
3038770
FM 4470
08/04/11
3041939
FM 4470
08/14/12
3047398
FM 4470
08/15/13
3047700
FM 4470
08/16/13
3050274
FM 4470
10/01/13
TrinitylERD
F8300.07.08
TAS 131/ ASTM D6878
07/30/08
F8300.11.08-R3
TAS 13l/ ASTM D6878
02/25/11
F45600.09.13-R1
TAS 131/ASTM D6878
12/30/13
PRI Construction Materials
FBP-054-02-05, RI
FM 4474/TAS 114 D
02/07/13
Technologies, LLC
FBP-069-02-01, RI
FM 4474/TAS 114 J
02/07/13
FBP-070-02-01, RI
FM 4474/TAS 114 J
02/07/13
FBP-085-02-01
TAS 114 J
10/04/12
FBP-086-02-01
TAS 114 J
10/04/12
FBP-044-02-01, R5
TAS 114 H, J
02/04/14
FBP-045-02-01
TAS 131/ASTM D6878
06/26/14
FBP-094-02-01
TAS 131/ASTM D6878
11/20/13
FBP-120-02-01
TAS 114 J
07/23/13
FBP-122-02-01, RI
TAS 114 J
02/04/14
FBP-125-02-01
TAS 114 C
07/23/13
FBP-148-02-01
TAS 114 J
12/18/13
FBP-149-02-01
TAS 114 J
12/18/13
FBP-153-02-01
TAS 114 J
12/18/13
FBP-154-02-02
TAS 114 J
12/18/13
NOA No.: 13-1212.04
Expiration Date: 02/03/20
Approval Date: O1/29/15
Page 6 of 89
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 71: Recover, Insulated
Deck Description: Min. 22 ga. steel deck with supports spaced maximum 6 ft. o.c. *The deck
shall record a Minimum Characteristic Resistance Force (MCRF) of 360 lbf.
when tested with Firestone Heavy -Duty fasteners installed through to the deck
in accordance with TAS 105.
System Type C(28): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA
Minimum''V2" thick I with 12 1:4 fe
DensDeck, SECUROCK Gypsum -Fiber Roof Board
Minimum ''/d' thick 1 with 12 1:4 fe
ISOGARD HD Composite
Minimum 1%11 thick 1 with 12 1:4 ft'
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: UltraPly TPO is bonded to the U1traPly TPO InvisiWeld Plates using a RhinoBond
Portable Bonding Tool and weighted RhinoBond Cooling Clamps. The minimum
6" wide roof cover side laps are sealed with a minimum 1.5" wide heat weld on
the outside edge of the lap.
Maximum Design
Pressure: -45 psf. (See General Limitation #7)
NOA No.:13-1212.04
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 52 of 89
RECOVER SYSTEM LIMITATIONS:
1. All System Limitations and General Limitations shall apply. See specific deck type Notice of
Acceptance for deck type System Limitations.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically
attached using the fastening pattern of the top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (n value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 ibf. Insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said
revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared,
signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant (When this limitation is specifically referred within this NOA, General
Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.:134212.04
Expiration Date: 02/03/20
Approval Date: 01/29/15
Page 89 of 89