Loading...
HomeMy WebLinkAboutCREEK TECHNICAL PAPPERSCREEK TECHNICAL SERVICES, LLC SCANNED (APPROVED ASSEMBLIES( BY IINSTALLATIONI; INOMENCLATUREI `St' Lucie County Johns Manville Corporation SBS Modified Roofing Systems APPENDIX B Mechanically Fastened Ll htwelghEConcrete Assemblies over Concrete Deck New or Existin ) System Vapor LWIC Base Sheet or Base Sheet or Insulation Ply Sheet Cap Sheet MDP No. Barrier Insulation Attachment s Min. 414 psi Celcore MF with Min. 1.8-inch Twin-Loc Nails and OPTIONAL CA SBS BUR Ply, CA SBS Cap; LC-M-13 OPTIONAL HS Rheology DynaFast 180 S Straight Line Batten Bar spaced 6- HA SBS BUR Ply; or HA SBS Cap; -im.5 SBS TA VB Admixture inch o.c. within the 4-inch wide heat TA SBS Ply or SBS Cap (Lim. 7) and Celcore S-1 welded side laps Min. 4-inch side laps) -i (Min. 4-Inch side laps) Min. 414 psi Min. 1.7-inch JM LWC CR Base -60 OPTIONAL Celcore MF with Fastener installed 12-inch o.c. in 4 (Lim. LC-M-14 SBS TA VB HS Rheology MA Base 2 Inch side laps, 12-inch o.c. in two (2) TA SBS Ply TA SBS Cap Non Non - Admixture Admixture and equally spaced, staggered rows in the HVHZ) Celcore S-1 field Min. 200 psi PermaPly 28 Min. 1.7-inch LWC Base Sheet Fastener installed 7-inch o.c. in 3-inch OPTIONAL _ SBS SBS Cap or -60 LC-M-15 _ go HA SBS BUR Ply it Meadcrete side laps, 7-inch o.c. in two (2) equally or TA SBS Ply TA SBS Cap (Lim. 7) spaced. staggered rows in the field Min. 475 psi DynaFast 180 HW, Min. 1.8-inch Twin-Loc Nails and OPTIONAL LC-M-16 OPTIONAL Celcore MF with DynaFast 180 S or Straight Line Batten Bar spaced 6- TA SBS Ply TA SBS Cap -60 SBS TA VB HS Rheology DynaFast 250 HW inch o.c. within the 4-inch wide heat (Min. flinch side laps) (Min. 4-inch side laps) (Lim. 7) Admixture welded side laps OPTIONAL Min. 400 psi DynaFast 180 HW, Ali Purpose Fasteners and High Load OPTIONAL TA SBS Cap LC-M-17 SBS TA VB Elastizell with or DynaFast 250 Plates spaced 12-Inch o.c. within min. TA SBS Ply 4-inch side laps) (-60 Lim. (LIm. 7) Zell -Crete Fibers HW 5-inch heat welded side laps Min. 4-inch side laps)(Min. OPTIONAL CA SBS Cap; OPTIONAL Min. 400 psi All Purpose Fasteners and High Load CA SBS BUR Ply, HA SBS Cap; LC-M-18 SBS TA VB Elastizell with DynaFast 180 S Plates spaced 12-inch o.c. within min. HA SBS BUR Ply; or or TA SBS Cap (-60 (Lim. 7) Lim. Zell -Crete Fibers 5-inch heat welded side laps TA SBS Ply (Min. 4-inch side laps) Min. 4-inch side laps Min. 475 psi Min. 1.8-inch Twin-Loc Nails and OPTIONAL CA SBS BUR Ply, CA SBS Cap; LC-M-19 OPTIONAL Celcore MF with DynaFast 180 S Straight Line Batten Bar spaced 6- HA SBS BUR Ply; or HA SBS Cap; -60 SBS TA VB HS Rheology inch o.c. within the 4-inch wide heat TA SBS Ply or TA SBS Cap (Lim. 7) Admixture welded side laps Min. 4-inch side laps) (Min. 4-Inch side laps) Min. 375 psi Min. 1.7-inch JM LWC Base Fastener CA SBS BUR Ply" CA SBS Cap or LC-M-20 OPTIONAL Celcore MF with PermaPly 28 Installed 6-inch o.c. in 4-inch side laps, in HA SBS BUR Ply; or HA SBS Cap -60 (Lim. 7) SBS HS Rheology 6-Inch o.c. three (3) equally TA SBS Ply TA SBS Cap Admixture spaced. staggered rows In the field TF-IfiaN Dgove Min. 400 psi PermaPly 28, Min. 1.7-inch JM LWC CR Base LC-M-21 with GlasBase Plus, Fastener installed 7-inch o.c. In 4-inch HA SBS BUR Pl,• or HA SBS Cap or -75 AElastizell Zell -Crete Fibers DynaBase, or sitle laps, 7-inch o.c. in two (2) equally TA SBS Ply TA SBS Cap (Lim. 7) Ventsulation Felt spaced, staggered rows in the field JMC14001.2 quality; product I0011FI IC1101a •ovided for Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or ; throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other not specifically addressed herein. i •,-�"�" CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Certficat1 ofAuthorization29824 No. Drive 17520 Edinburgh Drive Edinburgh Tampa, FL 33647 (813) 480-3421 2014 FLORIDA BUILDING CODE Manufacturer: JOHNS MANVILLE CORPORATION Issued November 1, 2015 P.O. Box 5108 Denver, CO 80217 (303)978-2478 www.im.com Manufacturing Plants: Southgate, CA Oklahoma City, OK Macon, GA Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Modified Bitumen Roof System Code Sections: 1504.3.1, 1504.6, 1504.7, 1507.2.9.2, 1507.6.5, 1507.10.2, 1507.11.2, 1515.1.1, 1515.1.4, 1515.2.4, 1523.1.1, 1523.6.2 Properties: Wind Resistance, Physical Properties, Impact Resistance PRODUCT DESCRIPTION 1J Products Specification Description D naBase ASTM D 6163 A glass reinforced SBS modified bitumen base sheet. naBase HW ASTM D 6163 A glass reinforced SBS modified bitumen base sheet for heat welded applications. D naBase PR ASTM D 6164 A polyester reinforced SBS modified bitumen base sheet. D naBase XT - ASTM D 6163 A glass reinforced SBS modified bitumen base or inner ply sheet. DynaFast 180 HW ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use In heat weld applications. DynaFast 180 S ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet. DynaFast 250 HIN ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. DynaGlas ASTM D 6163 A glass reinforced SBS modified bitumen membrane surfaced with granules. DynaGlas 30 FR ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. DynaGlas FR ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. DynaGlas FR CR ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating. DynaGlas FR CR G ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with reflective roofing granules. DynaGlas FR XT ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. DynaGrip Base SD/SA ASTM D 4601 Self -adhering, Type II asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built-up roofing. DynaKap FR T1 ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with granules. DynaKap FR T1 CR G ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with reflective roofing granules. DynaKap FR T1 HW CR G ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with reflective roofing granules for use in heat weld applications. DynaKap T1 ASTM D 6162 A composite reinforced SBS modified bitumen membrane surfaced with granules. Dynal-astic 180 ASTM D 6164 j A polyester reinforced SBS modified bitumen membrane surfaced with granules. Dynal-astic 180 FR ASTM D 6164 1 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules. JM14001.2 FL17013-112 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Johns Manville Corporation SBS Modified Roofing Systems Products Specification Description DynaLastic 180 FIR CR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules and a reflective while coating. DynaLastic 180 FIR CR G ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with reflective roofing granules. D nal-astic 180 S ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet. DynaLastic 250 FIR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules. DynaLastic 250 FIR CR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating. FIR CR G ASTM D 6164 A fire resistant. reinforced SBS modified bitumen membrane surfaced with reflective roofing granules S ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner I sheet. FIRASTM D 6162 Afire resistant, composite reinforced SBS modified bitumen membrane surfaced ffFRHW with rarules. FIR ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with ranules and a reflective white coating. ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with granules for use in heat weld applications. DynaMax FIR HW CR ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating for use in heat weld applications.. DynaMax FIR Plus ASTM D 6162 A fire resistant, composite reinforced SBS modified bitumen membrane surfaced with qranules. DynaMax S ASTM D 6162 A composite reinforced SBS modified bitumen base or inner ply sheet. DynaPly T1 ASTM D 6162 A composite reinforced SBS modified bitumen base or inner ply sheet. DynaWeld 180 S ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. DynaWeld 250 S ASTM D 6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. DynaWeld Base ASTM D 6163 A glass reinforced SBS modified bitumen base sheet for heat welded applications. DynaWeld Cap 180 FIR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with itranules for use in heat weld applications. DynaWeld Cap 180 FIR CR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating for use in heal weld applications. DynaWeld Cap 250 ASTM D 6164 A polyester reinforced SBSmodified bitumen membrane surfaced with granules for use in heal weld applications. DynaWeld Cap 250 FIR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules for use in heat weld applications. DynaWeld Cap 250 FIR CR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced with granules and a reflective while coating for use in heat weld applications. DynaWeld Cap 250 FIR CR ASTM D 6164 A fire resistant, polyester reinforced SBS modified bitumen membrane surfaced G with reflective granules for use in heat weld applications. DynaWeld Cap FIR ASTM D 6163 Afire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules for use in heat weld applications. DynaWeld Cap FIR CR ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with- ranules and a reflective white coating for use in heal weld applications. DynaWeld Cap FIR CR G ASTM D 6163 Afire resistant, glass reinforced SBS modified bitumen membrane surfaced with reflective roofing granules for use in heat weld applications. DynaWeld Cap FIR XT ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with ranules for use in heat weld applications. GlasBase Plus ASTM D 4601 Type II asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built-up roofing. GlasKap ASTM D 3909 A mineral surfaced, asphalt coated, fiberglass cap sheet. GlasKap CR ASTM D 3909 A white mineral surfaced, white acrylic coated, fiberglass cap sheet. GlasPly IV ASTM D 2178 Type IV asphalt impregnated glass felt for use in conventional and modified bitumen built-up roofing. GlasPly Premier ASTM D 2178 Type VI asphalt impregnated glass felt for use in conventional and modified bitumen built-u roofin . PennaPly 28 ASTM D 4601 Type II asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built-up roofing. Ventsulation Felt ASTM D 4897 Heavy duty fiber glass base sheet impregnated and coated on both sides with asphalt with or without fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in asphaltic coating. JM14001.2 FL17013-R2 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CR E E K fC f� TECHNICAL SERVICES, LLC REFERENCES Johns Manville Corporation SBS Modified Roofing Systems iuk Report No. Standards (Year) Atlantic & Caribbean Roof Consulting, LLC (TST4671) ACRC 06-003 TAS 114 (1995') Atlantic & Caribbean Roof Consulting, LLC (TST4671) ACRC 06-005 TAS 114 (J) (1995) Atlantic & Caribbean Roof Consulting, LLC (TST4671) ACRC 06-009 TAS 114 (D) (1995 ) Atlantic & Caribbean Roof Consulting, LLC (TST4671) ACRC 07-014 TAS 114 (1995') Atlantic & Caribbean Roof Consulting, LLC (TST4671) ACRC 14-035 TAS 114 (1995) IRT-ARGON (TST5296) 02-011 TAS 114 (J) (1995) IRT-ARCON (TST5296) 02-026 TAS 114 (J) (1995) FM Approvals (TST1867) OW6A2.AM FM 4470 (1992) FM Approvals (TST1867) OXOA9.AM FM 4470 (1992) FM Approvals (TST1867) OX7A4.AM FM 4470 (1992) FM Approvals (TST1867) OZ8A9.AM FM 4470 (1992) FM Approvals (TST1867) 107A4.AM FM 4470 (1992) FM Approvals (TST1867) 3000949 FM 4470 (1992) FM Approvals (TST1867) 3001457 FM 4470 (1992) FM Approvals (TST1867) 3001482 FM 4470 (1992) FM Approvals (TST1867) 3001629 FM 4470 (1992) FM Approvals (TST1867) 3006346 FM 4470 (1992) FM Approvals (TST1867) 3007148 FM 4470 (1992) FM Approvals (TST1867) 3009499 FM 4470 (1992) FM Approvals (TST18" - 3011248 FM 4470 (1992) FM Approvals (TST1867) 3012064 FM 4470 (1992) FM Approvals (TST1867) 3012974 FM 4470 (1992) FM Approvals (TST1867) 3014090 FM 4470 (1992) FM Approvals (TST1867) 3020600 FM 4470 (1992) FM Approvals (TST1867) 3020703 FM 4470 (1992) FM Approvals CTST1867) 3026130 FM 4470 (1992) FM Approvals (TST1867) 3026151 FM 4470 (1992) FM Approvals (TST1867) 3036559 FM 4470 (1992) FM Approvals (TST1867) 3037222 FM 4470 (1992) FM Approvals (TST1867) 3037540 FM 4470 (1992) FM Approvals (TST1867) 3040986 FM 4470 (1992) FM Approvals (TST1867) 3043824 FM 4470 (1992) FM Approvals (TST1867) 3046174 FM 4470 (1992) FM Approvals (TST1867) 3D4A4.AM FM 4470 (1992) FM Approvals (TST1867) 3054150 FM 4470 (1992) PRI Construction Materials Technologies (TST5878) JMC-065-02-01 ASTM D 6163 (2000(2008)) PRI Construction Materials Technologies (TST5878) JMC-066-02-01 ASTM D 6163 (2000(2008)) PRI Construction Materials Technologies (TST5878) JMC-070.02-01 ASTM D 2178 (2004) PRI Construction Materials Technologies (TST5878) JMC-071-02-01 ASTM D 2178 (2004) PRI Construction Materials Technologies (TST5878) JMC-072-02-01 ASTM D 4601 (2004) PRI Construction Materials Technologies (TST5878) JMC-074-02-01 ASTM D 4897 (2001) PRI Construction Materials Technologies (TST5878) JMC-075-02-04.2 TAS 110 (2000); ASTM D 6164 (2005el); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) JMC-078-02-01 TAS 110 (2000); ASTM D 6298 (2005el); ASTM G155 (2005a) PRI Construction Materials Technologies (TST5878) JMC-081-02-01.02 TAS 117 (B & C) (1995) PRI Construction Materials Technologies (TST5878) JMC-091-02-01 ASTM D 4601 (2004) PRI Construction Materials Technologies (TST5878) JMC-093-02-01 ASTM D 4601 (2004) PRI Construction Materials Technologies (TST5878) JMC-096-02-01 TAS 117 (A & B) (1995) PRI Construction Materials Technologies (TST5878) JMC-105-02-01 TAS 110 (2000); ASTM D 6162 (200OA(2008)); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) JMC-106-02-01 ASTM D 6164 (2005el) PRI Construction Materials Technologies (TST5878) JMC-107-02-01 Rev 4 ASTM D 903 (1998(2010)); ASTM D 1876 (2008); ASTM D 5147 (2011a); TAS 117(A & B) (1995); TAS 114(C) (1995) PRI Construction Materials Technologies (TST5878) JMC-107-02-01 Rev 5 ASTM D 5147 (2011 a); ASTM D 4073; TAS 117(A & B) (1995); ASTM D 903 (1998(2010)); ASTM D 1876 (2008); TAS 114 (1995) PRI Construction Materials Technologies (TST5878) JMC-108-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-113-02-01 ASTM D 6164 (2005el) PRI Construction Materials Technologies (TST5878) JMC-114-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-11 B-02-02 FM 4474 (C) (2004); TAS 114 (C) (1995) PRI Construction Materials Technologies (TST5878) JMC-131-02-01 FM 4474 (B) (2004); TAS 114 (D) (1995) PRI Construction Materials Technologies (TST5878) JMC-132-02-01 FM 4474 (B) (2004); TAS 114 (D) (1995) JM14001.2 FL17013-R2 - Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-0. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. a C CREEK II Johns Manville Corporation G E K SBS Modified Roofing Systems TECHNICAL SERVICES, LLC ED& Report No. Standards (Year) PRI Construction Materials Technologies (TST5878) JMC-141-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-168-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-171-02-01 ASTM D 6163 (2000(2008)) PRI Construction Materials Technologies (TST5878) JMC-171-02-02 ASTM D 6163 (2000(2008)) PRI Construction Materials Technologies (TST5878) JMC-171-02-03 ASTM D 6164 (2005el) PRI Construction Materials Technologies (TST5878) JMC-171-02-04 ASTM D 6163 (2000(2008)); TAS 110 (2000); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) JMC-171-02-07 ASTM D6164 (2005e1); TAS 110 (2000); ASTM G 155 (2005a) PRI Construction Materials Technologies (TST5878) JMC-171-02-10 ASTM D 6162 (2000A(2008)) PRI Construction Materials Technologies (TST5878) JMC-171-02-11 ASTM D 6164 (2005el) PRI Construction Materials Technologies (TST5878) JMC-222-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-222-02-02A UL 1897 (2004) PRI Construction Materials Technologies (TST5878) JMC-222-02-02 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-225-02-01 FM 4474 (B) (2004) PRI Construction Materials Technologies (TST5878) JMC-234-02-01 ASTM D 6162 (2000A(2008)); ASTM D 5147 (2011 a); TAS 110 (2000) PRI Construction Materials Technologies (TST5878) JMC-234-02-02 ASTM D 6163 (2000(2008)); ASTM D 5147 (2011a); TAS 110 (2000) PRI Construction Materials Technologies (TST5878) JMC-234-02-03 ASTM D 6163 (2000(2008)); TAS 110 (2000) PRI Construction Materials Technologies (TST5878) JMC-234-02-05 ASTM D 6164 (2005el); TAS 110 (2000) PRI Construction Materials Technologies (TST5878) JMC-222-02-04 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMG-227-02-01 FM 4474 (D) (2004); TAS 114 (J) (1995) PRI Construction Materials Technologies (TST5878) JMC-234-02-06 FM 4474 (D) (2004); TAS 114 (J) (1995) TrinitylERD (TST6049) 00257.03.05-1 ASTM D 6162 (2000A(2008)); ASTM D 6163 (2000(2008)); .ASTM D 6164 (2005el); ASTM D 629812005ell) Trinity]ERD (TST6049) 02843.02.05-10 TAS 114 (1995 ) Trinity]ERD (TST6049) 02843.02.07 TAS 114 (1995) TrinityjERD (TST6049) 10390A-10.97-1 TAS 114 (1995) TrinityjERD (TST6049) 10390A-12.97-1 TAS 114 (19951) TrinityjERD (TST6049) 10391.01.03 TAS 114 (1995') TrinitylERD (TST6049) 4251.08.96-1 TAS 114 (1995') TdnityjERD (TST6049) J13700.05.10-1-R1 ASTM D 6163 (2000(2008)), ASTM G 155 (2005a) TrinitylERD (TST6049) J13700.05.10-1-R2 ASTM D 6164 (2005el); ASTM G 155 (2005a) Tdnity[ERD (TST6049) J17040.11.09 ASTM D 6164 (2005el) Tr nity(ERD (TST6049) J34190.03.11 TAS 114 (J) (19951) TrinitylERD (TST6049) J45020.07.13 TAS 114 (1995) Trinity)ERD (TST6049) J5260.03.07 TAS 114 (J) (1995) TrinityjERD (TST6049) J6990.12.07 ASTM D 6162 (2000A(2008)); ASTM D 6164 (2005el) TrinitylERD (TST6049) J7670.06.08 ASTM D 3909 (1997b(2004)) t Determined to be equivalent to FM 4470 (1992) and FM 4474 (2004). JM14001.2 FL17013-R2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attdbutes that are not specifically addressed herein. 1 CREEK Johns Manville Corporation SBS Modified Roofing Systems A TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4. 4. In the HVHZ, fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F') of 275 Ibf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 Ibf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified assembly. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall be submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and comer roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Outside the HVHZ, commonly used standards include RAS 117, FM LPDS 1-29, or ANSI/SPRI WD-1. 8. Reroofing applications shall be examined in accordance with FBC Section 1510 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened systems, a field withdrawal resistance test (TAS 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the system. For adhered systems; a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the assembly is not permitted, the MDP for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. JM14001.2 FL17013-R2 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT Johns Manville Corporation SBS Modified Roofing Systems The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. 10. ENSF.�s� No 74021 - 2015.11.0 * * * 1 19:04:57 �9 STATE OF :•�/�-05r00r 1c4 O R t P �j\� ` Florida da Regishary R. tration n P.E. 74021 .-.Slllll NAm 0o Organization No. ANE9541 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor vrill acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(4 pages) 2) APPENDIX B —Nomenclature and Approved Assemblies (26 pages) JM14001.2 FL17013-R2 1' F This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Johns Manville Corporation CREEK [APPROVED ASSEMBLIESI SBS Modified Roofing Systems TECHNICAL SERVICES, LLC [NOMENCLATUREI APPENDIX A INSTALLATION Note - Refer to the APPRovEo ASSEMBLIES section of this report within Appendix a for specific installation details of a selected assembly. Unless otherwise specified in this report the followma installation details shall be met for the named Droducts: Component Product Installation Detail #14 fasteners; Min. 3/4-Inch penetration through the top rib JM All Purpose Fastener of the steel deck or wood deck; Min. 1-inch penetration into concrete deck JM APB Plates 2-inch diameter, Galvalume steel plate with reinforcing ribs and barbs JM High Load Plates 2 3/84nch diameter, Galvalume steel plate with eyehooks JM High Load Fastener #15 fastener, Min. 3/4-inch penetration through the top rib of the steel deck or wood deck JM High Load LH Fastener Large Head #15 fastener, Min. 3/4-inch penetration through the lop rib of the steel deck or wood deck JM Lightweight Concrete (LWC) Base Min. 1.7-inch shank; Pre -Assembled with 2.7-inch Fastener galvalume coated steel plate. Full embedment of shank into substrate JM Metal Membrane Batten Membrane anchors and metal strips Min. 2-inch embedment into gypsum or cementitious wood JM Polymer Auger Fastener fiber decks Fastening Systems JM Polymer Auger Plate 3" Fotr use with Polymer Auger Fastener, 34nch round plate JM Polymer Membrane Batten Membrane anchors and plastic strips JM Structural Concrete Fasteners Hammer -in fasteners; Min. 14nch penetration into concrete deck JM UltraFast Fastener #12 Hex Head #12 fastener, Min. 3/4-inch penetration through the top rib of the steel deck or wood deck JM UltraFast 3" Round Metal Plate 3-inch diameter round; Galvalume steel plate JM UltraFast Plastic Plate 3-inch diameter round; High Density Polyolefin plate JM UltraFast Metal Plate (Square) 3-inch square; Galvalume steel plate Min. 1.4-inch shank; Pre -Assembled with 2.7-inch JM UIVaLok galvalume coated steel plate. Full embedment of shank into substrate Trufast Deep Well Batten Bar Galvalume steel membrane batten with recessed holes Trufasl Straight Line Batten Bar Galvalume steel membrane batten for use with Twin-Loc Nail without integrated plate Trufasl Twin-Loc Nail Min. 1.4-inch shank; Base sheet fastener with and without integrated 2.7-inch diameter plate. JM Two -Part Urethane Insulation Ribbon adhered in 314 to 1-inch wide beads Adhesive Insulation Adhesives JM Roofing System Urethane Adhesive Ribbon adhered in 1/2 to 3/4-inch wide beads ASTM D 312, Type IV Asphalt Fully adhered within the EVT range at a rate of 2040 Ibs1100 ft JM MBR Bonding Adhesive Fully adhered at a rate of 1.5-2.0 gaV100 ft2 JM MBR Cold Application Adhesive Membrane ADCO Millennium Hurricane Force 1-Part Fully adhered at a rate of 2.0-2.5 gall100 IF Adhesives Membrane Adhesive ADCO Millennium Hurricane Force Ribbon adhered in 1-inch wide beads Membrane Adhesive Georgia-Pacific DensDeck Min. 1/4-inch thick; Adhered boards shall be a maximum 4- Georgia-Pacific DensDeck Prime ft x 4-ft JM ENRGY 3 and tapered JM ENRGY 3 AGF and tapered Insulation/Cover Min. 1/24nch thick; Min. 20 psi; Adhered boards shall be a Boards maximum 4-ft x 4-11 JM ENRGY 3 CGF and tapered JM ENRGY 3 FR and tapered rJM IJM Invinsa Roof Board Min. 1/4-inch thick; Adhered boards shall be a maximum 4- 1 1 ft x 4-ft JM14001 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Johns Manville Corporation CREEK rAPPROVED ASSEMBLIESI SBS Modified Roofing Systems TECHNICAL SERVICES, LLC [NOMENCLATUREI APPENDIX A Component Product Installation Detail JM Invinsa FR Roof Board Min. 1/4-inch thick; Adhered boards shall be a maximum 4- ft x 4-ft JM DuraBoard Min. 1/2-inch thick; Adhered boards shall be a maximum 4- It x 4-ft JM Retro-Fit Board JM RetoPlus Roof Board JM Fesco Board Min. 3/4-inch thick; Adhered boards shall be a maximum 4- ftx4-ft JM SECUROCK Gypsum -Fiber Roof Board Min. 114-inch thick; Adhered boards shall be a maximum 4- It x 4-ft JM SECUROCK Glass -Mat Roof Board JM DuraFoam Min. 1.5-inch thick; Adhered boards shall be a maximum 4- ft x 4-ft JM FescoFoam Base/Ply Sheets I DynaBase Min. 3-inch vide side -laps; Min. 6-inch end laps; Side -laps shall be installed perpendicular to the direction of the steel deck ribs and parallel to the direction of the wood trusses for mechanically attached systems DynaBase HW DynaBase PR DynaBase XT DynaFast 180 HW DynaFast 180 S DynaFast 250 HW Dynal-astic 180 S Dynal-astic 250 S DynaMax S aPly Tt DynaWeld 180 S DynaWeld 250 S DynaWeld Base GlasBase Plus GlasPly IV GlasPly Premier PennaPly 28 Ventsulation Felt DynaGrip Base SD/SA Min. 3 5/8-inch side -laps; Self -adhered Cap Sheets DynaGlas Min. 3-inch side -laps; Min. 6-Inch end -laps; DynaGlas 30 FR DynaGlas FR DynaGlas FR CR DynaGlas FR CR G DynaGlas FR XT DynaKap FR T1 DynaKap FR T1 CR G DynaKap FR TI HW CR G DynaKap TI DynaLastic 180 DynaLastic 180 FR Dynal-astic 180 FR CR Dynal-astic 180 FR CR G Dynal-astic 250 FR Dynal-astic 250 FR CR naLastic 250 FR CR G DynaMax FR DynaMax FR CR DynaMax FR HW DynaMax FR HW CR DynaMax FR Plus DynaWeld Cap 180 FR JM14001.2 FL17013-R2 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Johns Manville Corporation CREEK rAPPROVED ASSEMBLIESI SBS Modified Roofing Systems TECHNICAL SERVICES, LLC MOMENCLATUREI APPENDIX A Component Product Installation Detail DynaWeld Cap 180 FR CR DynaWeld Cap 250 DynaWeld Cap 250 FIR DynaWeld Cap 250 FIR CR DynaWeld Cap 250 FIR CR G DynaWeld Cap FIR DynaWeld Cap FIR CR DynaWeld Cap FIR CR G DynaWeld Cap FIR XT GlasKap GlasKap CR Celcore MF Slurry coat min. 1/8-inch thick; 1-inch thick EPS board (1 ibs/ft ); Min. 2-inch thick top coat; Celcore PVA curing compound applied at rate of 300 ft /gal Celcore MF with HS Rheology Admixture Cellular Lightweight Concrete Celcore 8-1 Steel deck is treated by applying a continuous film with a broom prior to placement of the Celcore lightweight concrete Meadcrete Slurry coat min. 1/8-inch thick; Min. 1-inch thick EPS board (1 Ibs/ft'); Min. 2-inch top coat; Elastizell COncrecel Cellular Lightweight Concrete Insulation/Cover Board Fastening Patterns 3 Spaces @ 24" 6" —1.1 iz* f— 4— 11 1f T + + I + + I + + + f + + .I + + 1 +f ( + 6,. + + + j + + , + + �� 12" t ��-36"—►� 6 per 4-ftx 8-ft board (Max.4.0-f? contributory area per fastener) 16 per 4-ftx 8-ft board (Max.2.0-e contributory area per fastener) + + + + + ( ( s- f + + + + + + + + IW +-+-+-+ -+ _ + . + + + + f—►11r1�— 18 per 4-ft x 8-ft board (Max. 1.78-ftcontributory area per fastener) 22 per 4-ft x 8-ft board (Max. 1.45-1`tz contributory area per fastener) JM14001.2 FL17013-R2 q P This evaluation report is provided for State of Florida product approval under Rule 61 G 3. ur s I oti K Technical Services, LLC of any product changes or quality assurance changes throughout the dura i i s valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 1 � 6 + + + + + + + + 18"= —►( 6"1 16" 4- 24 per4-ft x 8-ft board (Max. 1.33-fig contributory area per Johns Manville Corporation SBS Modified Roofing Systems APPENDIX A l r 7 Spaces @ 12" _r _ rd —ter !+ + + t t + + 3 Sp cep + + + + + + + t �12" + + + + + + t T24 32 per 4-ft x 8-ft board 1.0-fe contributory area per fastener) JM14001.2 FL17013-R2 Page 4 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Johns Manville Corporation CREEK rAPPROVED ASSEMBLIESI SBS Modified Roofing Systems TECHNICAL SERVICES, LLC rINSTALLATIONI; rNOMENCLATUREI APPENDIX B NOMENCLATURE The fallowing naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report. Refer to the nomenclature below when deciphering the allowable products for use in the selected assembly. Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report. Name Definition 2-Part UTA JM Two Part Urethane Insulation Adhesive AP Fasteners & Plates All Purpose Fastener and UltraFast 3" Round Metal Plate or UltraFast Square Recessed Metal Plate APB Fasteners & Plates JM APB Plates and JM High Load Fasteners As Tested Information provided to thereport user based on the as tested condition of the roofs stem CA SBS BUR Ply One or more plies of GlasBase Plus, PermaPly 28, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly Tt fully bonded in MBR Cold Application Adhesive DynaGlas, DynaGlas 30 FR, DynaGlas FR, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas FR XT, DynaLastic l80, DynaLastic l80 FR, DynaLastic CA SBS Cap 180 FR CR, DynaLastic 180 FR CR G, DynaLastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G, DynaKap T1, DynaKap T1 FR. DynaKap FR T1 CR G, DynaMax FR, DynaMax FR CR, or DynaMax FR Plus fully bonded in MBR Cold Application Adhesive CA SBS Ply One or more plies of DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 fully bonded in MBR Cold Application Adhesive One layer of any of the following products: -Georgia-Pacific DensDeck -Georgia-Pacific DensDeck Pdme Cover Board JM Invinsa Roof Board -JM Invinsa FR Roof Board JM SECUROCK Glass -Mat Roof Board -JM SECUROCK Gypsum -Fiber Roof Board All decks shall be designed by others in accordance with FBC requirements. As Tested deck construction details are described as follows: Concrete Deck Min. f. = 2,500 psi at 28 days Min. 22 ga, (Fr, = 33 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC; 0.5% Vented for LWIC applications only. The fallowing nomenclature is used to further describe the As Tested condition: F<#> Number <#> #12-24 HWH self -drilling screws or equivalent fastener at each flute used to secure the deck to the structural supports; Min. 1/4-inch penetration G<#> Min. Grade <#> of Steel Deck Deck Detail Steel Deck L<#> Max. span of <#> ft P Min. 5/8-Inch diameter puddle welds at each flute used to secure the deck to the structural supports S<#I> 1/4 "-14 HWH x7/8" self -drilling screws or equivalent fastener secured <#>-inch o.c. along the panel side laps W 3/4-inch O.D. flat washer used with indicated fastener The following nomenclature is used to further describe the As Tested condition: T<#> Min. <#>-Inch thickness of the plywood Wood Deck L<#> Max. span of <#> inches JMC14001.2 FL17013-R2 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. _ Johns Manville Corporation CREEK (APPROVED ASSEMBLIES SBS Modified Roofing Systems TECHNICAL SERVICES, LLC rINSTALLATIONI; jNOMENCLATUREj APPENDIX B Name Definition 10d-<#1>/<#2> 10d ring shank nails; Secured <#1>-inch o.c. at all intermediate supports and <#2> -o.c. at the perimeter of each board 6d-<01>/<#2> 8d ring shank nails; Secured <#1>-inch o.c. at all Intermediate supports and <#2> -o.c. at the perimeter of each board #8-<#1>/<#25 #8 x 2-Inch wood screws; Secured 41>-Inch o.c. at all intermediate supports and <#2> -o.c. at the perimeter of each board #12-<#1>/<#2> #12-3" Olympic STC screws; Secured <#1>-Inch o.c. at all intermediate supports and <92> -o.c. at the perimeter of each board DensDeck Min. 1/4-inch Georgia-Pacific DensDeck DensDeck Prime Min. 1144nch Georgia-Pacific DensDeck Prime E3 JM ENRGY 3, JM ENRGY 3 AGF, or JM ENRGY 3 CGF. JM ENRGY 3 FR permitted to be used ins stems as loose fill layer only. HA SBS BUR Base One ply of PermaPly 28, DynaBase, DynaBase XT, or GlasBase Plus fully banded in ASTM D 312, Type IV Asphalt HA SBS BUR Base 2 One ply of PermaPly 28, GlasPly IV, GlasPly Premier, DynaBase, DynaBase XT, DynaPly Tt or GlasBase Plus fully bonded in ASTM D 312, Type IV Asphalt HA SBS BUR Ply One or more plies of GlasPly IV, GlasPly Premier, GlasBase Plus, PermaPly 28, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 fully bonded in ASTM D 312, Type IV Asphalt One or more plies of DynaGlas, DynaGlas 30 FR, DynaGlas FR, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas FR XT, DynaLastic 180, HA SBS Cap DynaLastic 180 FR, DynaLastic 180 FR CR, DynaLastic 180 FR CR G. DynaLastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G. DynaKap T1, DynaKap T1 Fit, DynaKap FR T1 CR G, DynaMax FR, DynaMax FR CR, or DynaMax FR Plus fully bonded in ASTM D 312, Type IV Asphalt HA SBS Ply One ply of DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 fully bonded in ASTM D 312. Type IV Asphalt HL Fasteners 8 Plates JM High Load Fasteners and JM High Load Plates INVINSA JM Invinsa or JM Invinsa FR Roof Board One of more layers in any combination of. -JM DuraBoard -JM DuraFoam -JM ENRGY 3 -JM ENRGY 3 AGF -JM ENRGY 3 CGF -JM ENRGY 3 FR Insulation -JM Fesco Board -JM FescoFoam -JM Invinsa Roof Board -JM Invinsa FR Roof Board, JM Retro-Fit Board ' -JM RetroPlus Roof Board JM SECUROCK Glass -Mat Roof Board JM SECUROCK Gypsum -Fiber Roof Board LWIC Poured -in -place Cellular Lightweight Concrete with encapsulated insulation board MA Base One ply of PermaPly 28, GlasBase Plus, Ventsulation Felt, DynaBase, DynaBase XT, DynaBase PR, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaMax S. or DynaPly T1 mechanically attached as prescribed per the approved assembly JMC14001.2 FL17013-R2 Page 2 of 26 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC [APPROVED ASSEMBLIES I'INSTALLATIONI; rNOMENCLATURE1 Johns Manville Corporation SBS Modified Roofing Systems APPENDIX B Name Definition MA Base 2 One ply of DynaBase, DynaBase XT, DynaBase PR, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S. DynaMax S, or DynaPly T1 mechanically attached as prescribedper the approved assembly MA Base 3 One ply of GlasBase Plus, Ventsulalion Felt, DynaBase, DynaBase XT, DynaBase PR, DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaMax S, or DynaPly T1 mechanically attached as prescribed per the approved assembly MBR BA SBS BUR Base One ply of PermaPly 28, DynaBase, DynaBase XT, or GlasBase Plus fully bonded In MBR Bonding Adhesive MBR BA SBS BUR Ply One or more plies of GlasBase Plus, PermaPly 28, Dynal-astic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, D naMax S, or D naPI T1 full bonded in MBR BondingAdhesive One or more plies of DynaGlas, DynaGlas 30 FR, DynaGlas FR, DynaGlas FR CR, DynaGlas FR CR G, DynaGlas FR XT, DynaLastic 180, MBR BA SBS Cap DynaLastic 180 FR, DynaLastic 180 FR CR, DynaLastic 180 FR CR G, DynaLastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G, DynaKap T1, D naKap T1 FR, DynaKap FR T1 CR G, DynaMax FR, DynaMax FR CR, or DynaMax FR Plus fully bonded in MBR Bonding Adhesive MBR BA SBS Ply One or more plies of Dynalastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 fully bonded in MBR Bonding Adhesive MBR RA SBS Ply One or more plies of DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 fully bonded in ADCO Millennium Hurricane Force Membrane Adhesive MCRF Minimum Characteristic Resistance Force as determined by TAS 105 for the named fastener in the selected assembly MDP Maximum Design Pressure Preliminarily Secured Fastened at minimum rate of five (5) fasteners per 4-ft x 8-fit board or four 4 fasteners per 4-fix 4-ft board RA SBS Ply One or more plies of DynaLastic 180 S, DynaFast 180 S, DynaLastic 250 S, DynaBase, DynaBase XT, DynaBase PR, DynaMax S, or DynaPly T1 ribbon adhered In ADCO Millennium Hurricane Force Membrane Adhesive Where assemblies are used to recover an existing roof, the existing roof shall consist of only one layer of roofing, i.e. recovering a previously recovered Recover roof is not permitted. Recover roofing shall be conducted in compliance with FBC Section 1510 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened roof assemblies, i.e. systems x-M-#, the insulation layer is optional, or any INSULATION board or slip sheet may be used as separation layer prior to installing the approved roof assembly. RSUA JM Roofing System Urethane Adhesive SBS TA VB One ply DynaBase HW torched adhered over concrete deck prepared with ASTM D 41 primer SC Fasteners & Plates JM Structural Concrete Fastener and UltraFast 3" Round Metal Plate or UltraFast Square Recessed Metal Plate SECUROCK Min. 1/4-inch JM •SECUROCK Gypsum -Fiber Roof Board DynaWeld Cap FR, DynaWeld Cap FR CR, DynaWeld Cap FR CR G, DynaWeld Cap FR XT, DynaWeld Cap 180 FR, DynaWeld Cap 180 FR CR, TA SBS Cap DynaWeld Cap 250, DynaWeld Cap 250 FR, DynaWeld Cap 250 FR CR, DynaWeld 250 Cap FR CR G, DynaKap FR Tt HW CR G, or DynaMax FR HW, or DynaMax FR HW CR fully bonded by torch adhering TA SBS Ply One or more plies of DynaWeld Base, DynaBase HW, DynaWeld 180 S, DynaFast 180 HW, DynaWeld 250 S, DynaFast 250 HW fully bonded by torch adhering OF Fasteners & Plates UltraFast Fastener with UltraFast 3" Round Metal Plate or UltraFast Square Recessed Metal Plate JMC14001.2 FL17013-R2 Page 3 of 26 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED ASSEMBLIES ]APPROVED ASSEMBLIES] fINSTALLATIONi; [NOMENCLATURE'I Johns Manville Corporation SBS Modified Roofing Systems APPENDIX B The following notes shall be observed when using the assembly tables below. 1. MDPs were calculated using a 2:1 margin of safety per FBC Section 1504.9 and 1523.4. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on -center (0 C.) spacing given is the maximum allowable attachment spacing for the rated system. 5. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. JMC14001.2 Assembly System Numbers and Definitions ' C-A# Assemblies with All Layers Adhered over Concrete Deck New or Existing) C-AM-# Assemblies with Adhered Membranes over Insulated Concrete Deck New, Existing, or Recover) C-M-# Mechanically Fastened Assemblies over Concrete Deck New, Existing, or Recover) CW-A# Assemblies with All Layers Adhered over Cementitious Wood Fiber Deck New or Existin CW-AM-# Assemblies vdth Adhered Membranes over Insulated Cementitious Wood Fiber Deck New, Existing or Recover) CW-M-# Mechanically Fastened Assemblies over Cementitious Wood Fiber Deck New, Existing, or Recover) G-A-# Assemblies with All Layers Adhered over Poured Gypsum Deck New or Existing) G-AM-# Assemblies with Adhered Membranes over Insulated Poured Gypsum Deck New, Existing or Recove G-M-# Mechanically Fastened Assemblies over Poured Gypsum Decic New, Existing, or Recover) LC -A-# Lightweight Concrete Assemblies with All Layers Adhered over Concrete Deck New or Existing) LC-M# Mechanically Fastened Lightweight Concrete Assemblies over Concrete Deck New or Existing) LS-M# Mechanically Fastened Lightweight Concrete Assemblies over Steel Deck New or Existing) R-M# Mechanically Fastened Assemblies over Recoverwith Adhered Membranes S-AM# Assemblies with Adhered Membranes over Insulated Steel Deck New, Existing, or Recove S80-AM# Assemblies with Adhered Membranes over Insulated over Grade 80 Steel Deck New, Existing. or Recover) S-M# Mechanically Fastened Assemblies over Steel Deck New, Existing, or Recover) S80-M# Mechanically Fastened Assemblies over Grade 80 Steel Deck New, Existing, or Recover) W-AM# Assemblies with Adhered Membranes over Insulated Wood Deck New, Existing, or Recover) W-M# I Mechanically Fastened Assemblies over Wood Deck New, Existing, or Recover) FL17013-R2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.