HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTt \,,,---veriZonwireiess
July 17, 2015
Ms. Gail Wendt
Craig & Associates
Consultant to Verizon Wireless
777 Yamato Road, Suite 600
Boca Raton, FL 33431
SCANNED
BY
St. Lucie County
CALTROP®
CALTROP Corporation
13067 Telecom Parkway
Tampa, FL 33637
(813)514-9880
Subject: Rigorous Structural Analysis Report
Carrier Designation: Verizon: 62713 — Spain Tower
CALTROP Project Number: - 130-752.43
Site Information: 6189 North US 1
Fort Pierce, St Lucie County, FL 34951
Latitude 27.546325*N, Longitude 80.36853055°W
480' Guyed Tower
Dear Ms. Wendt:
CALTROP Corporation (CALTROP) is pleased to submit this Rigorous Structural Analysis Report to
determine if the subject tower is able to support certain proposed additional loads.
It is our understanding that Verizon Wireless (Verizon) desires to install new telecommunication equipment
on the subject tower. This analysis was based on the supporting information listed in Table 3.0. Our
services were performed in accordance with the terms and conditions of the existing field services
agreement between CALTROP and Verizon. This report summarizes the results of our findings.
The purpose of this analysis is to determine the suitability,of.the aforementioned tower to support the
loading indicated in Table 2.2. This analysis has been'performed in accordance with the TIA-222-G
standard, based upon a nominal 3-second gust reference wind speed of 122 mph with no ice. Based on our
Tower: *Pass at 102.9%, Foundation: Pass at 99.2% 11
This report has been prepared for the purpose of providing a structural evaluation of the subject
telecommunications tower for the loading conditions indicated. It is intended for the exclusive use of
Verizon. The information, assumptions,.and-reeoinmendations contained in this report should not be used
by others for any purpose without express writfen authorization from CALTROP. We appreciate the
opportunity to provide our professional services to you and look forward to continuing our relationship. If
we can be of any further assistance, please do not hesitate to call. "S IJ s� s1111'r
Sincerely,
CALTROP CORPORATION
Eliezer Diaz, E.I. Michael A. Phillips, P.E';
Project Engineer Principal Engineer
Registered, Floria 1 0015843 Registered, Florida 68312
+� Rigorous Structural Analysis Report— lrerizon: 62713 — Spain Tower July 17, 2015
CALTROP Corporation
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 ANALYSIS CRITERIA
Table 2.1—Analysis Criteria
Table 2.2—Appurtenance Loading
3.0 ANALYSIS PROCEDURES
Table 3.0—Supporting Information
3.1 Analysis Methods
3.2 Analysis Assumptions & Limitations
4.0 ANALYSIS RESULTS
Table 4.1—Tower Component Results
Table 4.2—Foundation Component Results
APPENDIX A
tnxTower Output
Page 2
Rigorous Structural Analysis Report — Verizon: 62713 — Spain Tower July 17, 2015
CALTROP Corporation
1.0 INTRODUCTION
The subject tower is a 480' tall guyed tower.
2.0 ANALYSIS CRITERIA
The tower was analyzed in accordance with the criteria indicated in Table 2.1 for the proposed and
existing/reserved antennas, transmission lines, and mountings shown in Table 2.2.
Table 2.1—Analysis Criteria
4 Criteria.
I
1)escriptibnl
Building Code
2014 Florida Building Code, First Printing
Standard
TIA-222-G Structural Standards for Steel Antenna Towers and Antenna
Supporting Structures (FBC 3108.1)
Ultimate Wind Speed
158 mph, 3-Second Gust (per FBC Table 1609A)
Nominal Wind Speed
122 mph (per FBC 1609.3.1 for use with TIA-222-G)
Exposure
C
Structure Class
II (Importance Factor = 1.0)
Radial Ice Thickness
Zero Inches
Topographic Factor
1
Crest Height
Zero Feet
- ,•
Center
R
aNumber
7 , ll
Line
Carrier
Number
Antenna,
.
Feed,
i Elevafiori_•
Name
of
Mfr:
' Antenna,Model
Mount
of Feed
'Liue'Size
(feet)!
Antennas
tines*
(inches)
480
Unknown
1
Unknown
Flash Beacon
Flush
1
%
442
Unknown
1
Andrew
DB224-E
Standoff
1
7/a
441.5
Unknown
1
Unknown
10' Dipole
Leg
1
7/8
422.5
Unknown
I
Unknown
10' Dipole
Leg
-
-
410
Unknown
I
Unknown
10' Omni
Standoff
1
I%
406
Unknown
1
Unknown
10' Dipole
Leg
-
373
Unknown
1
Unknown
18' Dipole
Standoff
1
Page 3
�Y Rigorous Structural Analysis Report — Verizon: 62713 —Spain Tower July 17, 2015
CALTROP Corporation
. Center
`
Number,
'Number"
Feed
Line
Carrier ,
of.,
Antenna -
1 AntennwN fbdel
'
Mount•
of Feed
hieSize
Elevation
3
Name
Antennas
1VIfr
."
-
Lines
(inches);
i (feet.)I
( )
370.5
Unknown
1
Unknown
20' Dipole
Standoff
1
%
356
Unknown
1
Unknown
4' Omni
Standoff
1
%
350
Unknown
1
Unknown
12' Omni
Standoff
1
1%
337
Unknown
1
Unknown
12' Omni
Standoff
-
317
Unknown
1
Dielectric
R55247
Standoff
1
1%
287.5
Unknown
2
Unknown
Yagi
Leg
1
%2
242
Unknown
1
Unknown
Flash Beacon
Standoff
1
5%
226
Verizon
3
CSS
X7-665
Boom
Gate
12
6
1%
1%
226
Verizon
6
CSS
AXP19-60-2
Boom
Gate
206.5
T-Mobile
3
RFS
APXV18-
Sector
206517S
Frame
206.5
T-Mobile
6
RFS
APXI7DW-
Sector
17DWVS
Frame
206.5
T-Mobile
6
RFS
ATMAP1412D-
1A20
12
1
15%
1'/a
206.5
T-Mobile
1
Raycap
RNSNDC-7771-
PF-48
206.5
T-Mobile
3
Nokia
FRIG (RRU)
-
206.5
T-Mobile
3
Nokia
FXFB (RRU)
-
195
AT&T
6
Kathrein
800-10122
Boom
Scala
Gate
195
AT&T
3
Kathrein
800-10764
Boom
Scala
Gate
18
2(Power)
1%
%
195
AT&T
12
Kathrein
860-10025RCU
Scala
1(Fiber)
I(RET)
%
%
ATM19801712-
195
AT&T
6
RFS
0 (TMA)
195
AT&T
6
RFS
FDGW5504-3C-
3 (diplexer)
195
AT&T
6
Ericsson
RRU-11
Page 4
Rigorous Shuclural Analysis Report — Verizon: 61713 — Spain Tower
CALTROP Corporation
July 17, 1015
( Center
Number
!
' Number,
Feed6
Line
Carrier
°f`
Antenna!
AntennaaVlodel•
Mount
of Feeda
'Line. $i'ze
i Elevation;
Name
Mfr:
i (feet) _
I Antennas;
E
Lines,*
(incl es)'�
195
AT&T
1
Raycap
DC6-48-60-18-
8F
i 72.5
6
Sea!
AP18
Sector
1900f090D
Frame
172.5
Sprint
3
RFS
APXV9ERR18-
Sector
C
Frame
172.5
Sprint
9
RFS
ACU-A20-N
-
172.5
Sprint
12
Ericsson
RRU-11
-
39mm
3
Hybrid
172.5
Sprint
3
Ericsson
RRU A2
-
172.5
Sprint
3
RFS
IBC1900HG-
1(combiner)
172.5
Sprint
3
Ericsson
800 ESMR
(filter)
116.5
Unknown
1
Unknown
3' Yagi
Standoff
1
%
104.5
Unknown
1
Unknown
6' Parabolic Grid
Leg
1
'/<
Dish
97.5
Unknown
1
Unknown
6' Parabolic Grid
Leg
1
%:
Dish
Legend: Proposed Appurtenances (Bold)
Existing Appurtenances (Regular)
Future/Reserved Appurtenances (Italic)ivo
E
0 *'—
3.0 ANALYSIS PROCEDURES ALG PY
(Strikethrough)
This analysis is based on published catalog information, the supporting information listed in Table 3.0, and
appurtenance information provided by Verizon.
Table 3.0—Supporting Information
Date
-. - Description's
By..
April 3, 2014
RFDS
Verizon
February 22, 2013
Tower Modification
CALTROP Corporation
January 7, 2013
Tower Analysis
CALTROP Corporation
November 21, 2012
RFDS
Sprint
September 25, 2012
RFDS
AT&T
Page 5
Rigorous Structural Analysis Report — Yerizan: 62713 —Spain Tower July 17, 2015
CALTROP Corporation
July 23, 2012
Tower Mapping
Tower Engineering Professionals,
Inc.
June 26, 2012
RFDS
T-Mobile
June 12, 2012
Preliminary Construction Drawings
Foresite Group, Inc. [for Verizon]
April 23, 2012
Site Visit Investigation
CALTROP Corporation
April 2, 2009
Tower and Foundation Analysis
MACTEC Engineering and
Consulting, Inc.
March 26, 2009
Geotechnical Report
FDH Engineering, Inc.
March 5, 2009
Foundation Mapping
FDH Engineering, Inc.
August 23, 2002
Tower Modification Design
KCI Technologies, Inc.
May 6, 1998
Tower Design
Pirod, Inc.
Various
Miscellaneous Information
VerizonWireless
'01LE O
3.1 Analysis Methods
The tower superstructure analysis was performed with the use of tnxTower, a commercially available
software program designed for the analysis of telecommunications towers. The program was used to
create a three-dimensional mathematical model of the tower and to calculate member stresses under the
appropriate dead, live, and wind loads. Loads were computed in accordance with applicable portions of
the TIA-222-G standard. Selected output from the analysis is included in Appendix A.
A separate analysis of the tower foundation system was performed by comparing the factored reactions
from the tnxTower superstructure analysis to the foundation capacities indicated in the previous analysis
by CALTROP Corporation dated February 22, 2013.
3.2 Analysis Assumptions and Limitations
• Information in the original design drawings or in the previous analysis that could not be verified
by CALTROP personnel is assumed to be correct.
• All tower components are assumed to be in adequate condition to carry their full design capacity.
• The configuration of antennas, transmission cables, mounts and other appurtenances is assumed
to be as specified in this report.
• Limitations for antenna twist, tilt, roll, or lateral translation are not considered in this analysis,
since the effects of these factors on structural tower performance are typically negligible.
• Automatic calculations of Ka used by tnxTower for feedlines and appurtenances.
• Unbraced length factor adjusted for bracing members per TIA-222-G Table 4-5.
• Emergency/essential communication equipment is not located on the tower.
• This analysis does not consider the capacity of the antenna mounting systems.
• The foundation was constructed to support its full design loading.
• The tower modification design dated February 22, 2013 has been fully implemented.
If any of the above assumptions are not valid or have been made in error, this analysis may be affected,
and CALTROP should be allowed to review any new information to determine its effect on the structural
integrity of the tower.
Page 6
, Rigorous Structural Analysis Report— Yerizon: 62713 — Spain Tower July 17, 2015
CALTROP Corporation
4.0 ANALYSIS RESULTS
The following tables summarize analysis results for the tower superstructure and foundation system.
Table 4.1— Tower Component Results
i
4 Component
,M,ximum,Percents
Capacity Used4
Resultsi'
Leg
98.6
Pass
Diagonal
102.9
*Pass
Horizontal
14.9
Pass
Secondary Horizontal
55.3
Pass
Girt
88.2
Pass
Guy Cables
93.3
Pass
Torque Arm
19.3
Pass
*Note: Existing structural component stress ratios up to 105% are considered acceptable.
Table 4.2 — Foundation Component Results
Est:;
Percent
ComponenU
Reaction.
Capacity
Capacity.
Results
t
Used;
Mast Axial (Factored)
379 kips
456 kips
83.1
Pass
Guy Anchor Uplift (Factored)
163 kips
196 kips
83.2
Pass
Guy Anchor Shear (Service)
131 kips
132 kips
99.2
Pass
*Note: Existing structural component stress ratios up to 105% are considered acceptable.
}'s
�VY'4 x
Page 7
Rigorous Structural Analysis Report— VerLon: 62713 — Spain Tower July 17, 2015
CALTROP Corporation
APPENDIX A
Tower Input Data
The main tower is a 3x guyed tower with an overall height of 480.00 ft above the ground line.
The base of the tower is set at an elevation of 0.00 ft above the ground line.
The face width of the tower is 4.00 ft at the top and tapered at the base.
An index plate is provided at the 3 sided -tower connection.
There is a 3 sided latticed pole with a face width of 2.00 ft.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Basic wind speed of 122 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
Pressures are calculated at each section.
Stress ratio used in latticed pole member design is 1.
Safety factor used in guy design is 1.
Stress ratio used in tower member design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are
not considered.
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
Add IBC.6D+W Combination
Options
Distribute Leg Loads As Uniform
Assume Legs Pinned
Assume Rigid Index Plate
Use Clear Spans For Wind Area
Use Clear Spans For KUr
Retension Guys To Initial Tension
Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area of Appurt.
Autocalc Torque A" Areas
SR Members Have Cut Ends
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Page 8
Treat Feedline Bundles As Cylinder
Use ASCE 10 X-Brace Ly Rules
Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
Consider Feedline Torque
Include Angle Block Shear Check
Poles
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
Rigorous Structural Analysis Report— Verizon: 62713—Spain Traver
CALTROP Corporation
Wind 90
Leg
Wnd 180
I
Wind 0
Corner & Starmount Guyed Tower
Page 9
July 17. 2015
Rigorous Structural Analysis Report — yerizon: 62713 - Spain Tower
CALTROP Corporation
Wind 180
(7
Guy C
Face Guyed
3 Sided Latticed Pole Section Geometry
July 17, 2015
A
Tower
Tower Assembly
Description Section
Number
Section
Section
Elevation Database
Width
or
Length
Sections
R
It
It
L1
480.00-460.00
2.00
1
20.00
L2
460.00-440.00
2.00
1
20.00
L3
440.00-420.00
2.00
1
20.00
L4
420.00-400.00
2.00
1
20.00
3 Sided Latticed Pole Section Geometry
cont'd
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
K Brace
Horizontals
Offset
Offset
End
(t
R
Panels
in
in
Lt
480.00460.00
1.65
X Brace
No
No
1.5000
1.5000
L2
460.00-440.00
1.65
X Brace
No
Yes
1.6000
1.5000
L3
440.00420.00
1.65
X Brace
No
No
1.5000
1.5000
L4
420.00400.00
1.65
X Brace
No
No
1.5000
1.5000
Page 10
Rigorous Structural Analysis Report— Verizon: 62713—Spain Tower July 17, 2015
CALTROP Corporadon
3 Sided Latticed Pole Section Geometry cont'd
Tower
Leg
Leg
Leg
Diagonal
Diagonal
Diagonal
Elevation
Type
Size
Grade
Type
Size
Grade
It
L1 480.00-
Solid Round
1 1/2
A572-50
Solid Round
112
A36
460.00
(50 ksi)
(36 ksi)
L2 460.00-
Arbitrary Shape
2SR+Half 2XX Pipe
A572-50
Arbitrary
0.5625SR+0.75SR
A36
440.00
(50 ksi)
Shape
(36 ksi)
L3 "0.00-
Arbitrary Shape
2SR + Half 2STD Pipe
A572-50
Solid Round
9/16
A36
420.00
(50 ksi)
(36 ksi)
L4 420.00-
Solid Round
2 1/2
A572-50
Solid Round
3/4
A36
400.00
(50 ksi)
(36 ksi)
3 Sided Latticed Pole Section Geomet cont'd
Tower
Top Girt
Top Girt
Top Girt
Bottom Girt
Bottom Girt
Bottom Girt
Elevation
Type
Size
Grade
Type
Size
Grade
ft
L1 480.00-
Solid Round
3/4
A572-50
Solid Round
7/8
A572-50
460.00
(50 ksi)
(50 ksi)
L2 460.00- �.
Solid Round ..,
314
A572-50
Solid Round
7/8
A572-50
. 440.00
"
(50 ksi)
(50 ksi)
L3 440.00-
Solid Round -'
3/4
A572-60
Solid Round
7/8
A572-50
. 420.00 ', _.
`.. �-
' ' -
(50 ksi)
(50 ksi)
L4 420.00-
Solid Round
3/4
A572-50
Solid Round
7/8
A572-50
400.00
(50 ksi)
(50 ksi)
3 Sided Latticed Pole Section Geometry cont'd
Tower
No.
- Mid Girt
Mid Girt
Mid Girt
Horizontal
Horizontal Horizontal
Elevation
of
Type
Size
Grade
Type
Size Grade
Mid
it
Girls
L1 480.00-
1
Solid Round
3/4
A572-50
Solid Round
A572-50
460.00
(50 ksi)
(50 ksi)
L2 460.00-
1
Solid Round
3/4
A572-50
Solid Round
A572-50
440.00
(50 ksi)
(50 ksi)
L3 440.00-
1
Solid Round
3/4
A572-50
Solid Round
A572-50
420.00
(50 ksi)
(50 ksi)
L4 420.00-
1
Solid Round
3/4
A572-50
Solid Round
A572-50
400.00
(50 ksi)
(50 ksi)
3 Sided Latticed Pole Section Geometry cont'd
Page 11
Rigorous Structural Analysis Report- Perizon: 61713 -Spain Tower
CALTROP Corporation
July 17, 2015
Tower Secondary Secondary Horizontal Secondary Inner Bracing Inner Bracing Size Inner Bracing
Elevation Horizontal Type Size Horizontal Type Grade
Grade
It
L2 460.00- Solid Round 3/4 A572-50 Solid Round A36
440.00 (50 ksi) (36 ksi)
3 Sided Latticed Pole Section Geometry (cont'd)
Tower
Gusset
Gusset
Gusset Grade Adjust. Factor
Adjust.
Weight Mutt. Double Angle Double Angle
Elevation
Area
Thickness
At
Factor
Stitch Bolt
Stitch Bolt
(per face)
A,
Spacing
Spacing
Diagonals
Horizontals
it
ftz
in
in
in
L1480.00-
0.00
0.0000
A36 1
1
1 36.0000
36.0000
460.00
(36 ksi)
L2 460.00-
0.00
0.0000
A36 1
1
1 36.0000
36.0000
440.00
(36 ksi)
L3 440.00-
0.00
0.0000
A36 1
1
1 36.0000
36.0000
420.00
(36 ksi)
L4 420.00-
0.00
0.0000
A36 1
1
1 36.0000
36.0000
400.00
(36 ksi)
3 Sided Latticed Pole Section Geometry cont'd
K Factors'
Tower
Cale
Calc
Legs
X
K
Single
Girts
Horiz
Sec.
Inner
Elevation
K
K
Brace
Brace
Diags
Honz.
Brace
Single
Solid
Diags
Diags
Angles
Rounds
X
X
X
X
X
X
X
it
Y
Y
Y
Y
Y
Y
Y
L1480.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
460.00
0.7
0.7
0.7
0.7
0.7
0.7
1
L2 460.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
440.00
0.7
0.7
0.7
0.7
0.7
0.7
1
L3 440.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
420.00
0.7
0.7
0.7
0.7
0.7
0.7
1
L4 420.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
400.00
0.7
0.7
0.7
0.7
0.7
0.7
1
'Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the
out-0f-plane direction applied to the overall length. - e„ ,?
1 3 Sided Latticed Pole Section Geofhe`frv"� &5nt'dT I
Page 12
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
July 17, 2015
Tower
Elevation
ft
Leg
Diagonal
Top Girt
Bottom Girt
Mid
Girt
Long Horizontal
Short Horizontal
Net Width
U
Net
U
Net Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Width
Deduct
Width
Width
Width
Width
in
Deduct
in
Deduct
Deduct
Deduct
Deduct
in
in
in
in
in
L1480.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
460.00
L2 460.00-
0,0000
1
0.0000
0.75
0.0000
0.76
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
440.00
L3 440.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
420.00
L4 420.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
400.00
3 Sided Latticed Pole'Sectioii Geometry (cont'd)
Tower
Elevation
ft
Leg
Connection
Type
Leg
Bolt Size
No.
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short
Horizontal
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size
No.
in
in
in
in
in
in
in
L1480.00-
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
460.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
L2 460.00-
Flange
0.6260
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
440.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
L3 440.00-
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
420.00
A325N
A325N
A325N
A325N
A325N
A325N
A325N
L4420.00-
Flange
0.7500
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
400.00
A325N
A325N
A325N
A325N
A325N
A325N
A325N
Tower Section Geometry
Tower
Tower
Assembly Description
Section
Number
Section
Section
Elevation
Database
Width
of
Length
Sections
ft
it
It
T1
400.00-380.00
4.00
1
20.00
T2-T6
380.00-280.00
4.00
5
20.00
T7-T10
280.00-200.00
4.00
4
20.00
T11
200.00-192.50
4.00
1
7.50
T12
192.50-180.00
4.00
1
12.50
T13 .
.,160.00-160.00.'
4.00
1
20.00
T14-T20
160.00-26.00
4.00
7
20.00
T21
20.00-4.67
4.00
1
15.33
T22
4.67-0.00
4.00
1
4.67
Tower Section Geometry cont'd) . - -
Page 13
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower July 17. 2015
CALTROP Corporation
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
K Brace
Horizontals
Offset
Offset
End
/t
ff
Panels
in
in
T1
400.00-380.00
2.33
X Brace
No
No
4.0000
12.0000
T2-T6
380.00-280.00
2.33
X Brace
No
No
4.0000
12.0000
T7-T10
280.00-200.00
2.33
X Brace
No
No
4.0000
12.0000
T11
200.00-192.50
2.39
X Brace
No
Yes
4.0000
0.0000
T12
192.50-180.00
2.30
X Brace
No
Yes
0.0000
12.0000
T13
180.00-160.00
2.33
X Brace
No
No
4.0000
12.0000
T14-T20
160.00-20.00
2.33
X Brace
No
No
4.0000
12.0000
T21
20.00-4.67
2.33
X Brace
No
No
4.0000
12.0000
T22
4.67-0.00
1.11
X Brace
No
No
4.0000
12.0000
Tower Section, Geometry (cont'd)
Tower
Leg
Leg
Leg
Diagonal
Diagonal
Diagonal
Elevation
Type
Size
Grade
Type
Size
Grade
ff
T1 400.00-
Solid Round
2 1/4
A572-50
Solid Round
7/8
A36
380.00
(50 ksi)
(36 ksi)
T2-T6
Solid Round
2
A572-60
Solid Round
3/4
A36
380.00-280.00
(50 ksi)
(36 ksi)
T7-T10
Solid Round
2 1/4
A572-50
Solid Round
3/4
A36
280.00-200.00
(50 ksi)
(36 ksi)
T11 200.00-
Solid Round
2 1/4
A572-50
Solid Round
3/4
A36
192.50
(50 ksi)
(36 ksi)
T12 192.50-
Solid Round
2 1/4
A572-50
Solid Round
3/4
A36
180.00
(50 ksi)
(36 ksi)
T13 180.00-
Solid Round
2 1/2
A572-50
Solid Round
3/4
A36
160.00
(50 ksi)
(36 ksi)
T14-T20
Solid Round
2 1/2
A572-50
Solid Round
3/4
A36
160.00-20.00
(50 ksi)
(36 ksi)
T21 20.00-4.67
Solid Round
2 1/2
A572-50
Solid Round
3/4
A36
(50 ksi)
(36 ksi)
T22 4.67-0.00
Solid Round
2 1/2
A572-50
Solid Round
3/4
A. 6
(50 ksi)
(
�.".
Tower Section Geometry cont'd
Tower
Top Girt
Top Girt
Top Girt
Bottom Girt
Bottom Girt
Bottom Girt
Elevation
Type
Size
Grade
Type
Size
Grade
It
T1 400.00-
Solid Round
1
A572-50
Solid Round
1
A572-50
380.00
(50 ksi)
(50 ksi)
T2-T6
Solid Round
1
A572-50
Solid Round
1
A572-50
380.00-280.00
(50 ksi)
(50 ksi)
T7-T10
Solid Round
1
A572-50
Solid Round
1
A572-50
280.00-200.00
(50 ksi)
(50 ksi)
T11 200.00-
Solid Round
1
A572-50
Solid Round
A572-50
192.50
(50 ksi)
(50 ksi)
T12 192.50-
Solid Round
A572-50
Solid Round
1
A572-50
180.00
(50 ksi)
(50 ksi)
T13 180.00-
Solid Round
1
A572-50
Solid Round
1
A572-50
160.00
(50 ksi)
(50 ksi)
Page 14
m
rt
O O
+ O O
rri
O A++ N N O it O N.O O
O N O
< O
O+ O O N
C
O N O O N O 0RI
OO O O 0 0 0 0
O 0
O O
O O
fn V1 fn (n (n (n (n (n (n
O O
o
Z
_
O O O O O O O
H. 0
0 + + +
O
2 a 2 n 6 6 6 n- 6
O tl
m
N n
]] Am 7J ]] A .'0 ]] A
C C
n
C C C C C C C
V) M (n U)
O O O O
N
0 0 0 o
m
o
y
O
n a n n
W
y
O
1
s
N
�
m G
^D^D--D^D^D
n 41 Ut N N (P N (P fll N Ut w W (n Ut
Zm
'•
au, NGI
J V O V O V O V O V O V
d
c N F IV F N F IV F N JC N F lJ F N F N
so.N N. N
m CX
0 J n
O v v v O v O v O O O v
C=
\Y
O UDI N (Dll UI lDl1 Ut N
Q
F N F N JC N F N
d P
y m m y m m m
0 0
O O O O O O O
a a a a a a
J
M
M
2 G a
y
1Y
0 0 0 0 0 0 0 0 0
��
0 0 0 0
]
c c c c c c c c c
pS
O
O O
C C G C
m❑
�
Q
`m
w
a
ti ]
V1
N
y,
N p
m
fD
�
n D rn D rn D rn D w D x D I D I
m
C W F W F W F W F W F W T. W F W F w
f O O O O m� L. O O O O
m
0.
D^
N Ut N N N f>it N N
y7 m
v v v v V v v
m
J
F N F N F N F N
H. N.
a O
... .. w..a—a
,
m
m
N N m
n O
N O
00�
�m F
OFn
O N N
G O
+ N
j 1
Qy
O C
O OVf O
p
N W N
! p
P
o' i
� b
o O o
m
n o n
a
P
m
0
y
� b
N
w
I
a"
a'
0
R
nN NtDii Nm
j
N F N F N
n
0 0 0
0
n o n
y o
b
0 0 o
c C C
3
m
Jn a o
S
O
� o
Q
f
11 N N N N
�
v
N
O
fDli
S N F N x N
L7 �
N 3
4
n
Rigorous Structural Analysis Report - Verizon: 61713 - Spain Tower July 17, 2015
CALTROP Corporation
Tower Section Geometry (cont'd)
Tower
Gusset
Gusset
Gusset Grade Adjust. Factor
Adjust.
Weight Mult.
Double Angle
Double Angle
Elevation
Area
Thickness
At
Factor
Stitch Bolt
Stitch Bolt
(per face)
A,
Spacing
Spacing
Diagonals
Horizontals
It
fe
in
in
in
T1400.00-
0.00
0.0000
A36
1
1
1
36.0000
36.0000
380.00
(36 ksi)
T2-T6
0.00
0.0000
A36
1
1
1
36.0000
36.0000
380.00-
(36 ksi)
280.00
T7-T10
0.00
0.0000
A36
1
1
1
36.0000
36.0000
280.00-
(36 ksi)
200.00
T11200.00-
0.00
0.0000
A36
1
1
1
36.0000
36.0000
192.50
(36 ksi)
T12192.50-
0.00
0.0000
A36
1
1
1
36.0000
36.0000
180.00
(36 ksi)
T13180.00-
0.00
0.0000
A36
1
1
1
36.0000
36.0000
160.00
(36 ksi)
T14-T20
0.00
0.0000
A36
1
1
1
36.0000
36.0000
160.00-20.00
(36 ksi)
T2120.00-
0.00
0.0000
A36
1
1
1
36.0000
36.0000
4.67
(36 ksi)
T22 4.67-0.00
0.00
0.0000
A36
1
1
1
36.0000
36.0000
(36 ksi)
Tower
Elevation
ft
Calc
K
Single
Angles
Cola
K
Solid
Rounds
Legs
X
Brace
Diags
X
Y
K
Brace
Diags
X
Y
K Factors
Single Girls
Diags
X X
Y Y
Horiz.
X
Y
Sec.
Hodz.
X
Y
Inner
Brace
X
Y
T1400.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
380.00
0.7
0.7
0.7
0.7
0.7
0.7
1
T2-T6
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
380.00-
0.7
0.7
0.7
0.7
0.7
0.7
1
280.00
T7-T10
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
280.00-
0.7
0.7
0.7
0.7
0.7
0.7
1
200.00
T11200.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
192.50
0.7
0.7
0.7
0.7
0.7
0.7
1
T12192.50-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
180.00
0.7
0.7
0.7
0.7
0.7
0.7
1
T13180.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
160.00
0.7
0.7
0.7
0.7
0.7
0.7
1
T14-T20
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
160.00-
0.7
0.7
0.7
0.7
0.7
0.7
1
20.00
T2120.00-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
4.67
0.7
0.7
0.7
0.7
0.7
0.7
1
T22 4.67-
No
No
1
0.7
0.7
0.7
0.7
0.7
0.7
1
0.00
0.7
0.7
0.7
0.7
0.7
0.7
1
Page 16
Rigorous Structural Analysis Report- VerLon: 62713 - Spain Tower
CALTROP Corporation
July 17. 2015
'Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the
out -of -plane direction applied to the overall length.
Tower Sectiori Geometry (cont'd
Tower
Elevation
it
Leg
Diagonal
Top Girt
Bottom
Girt
Mid
Girt
Long Horizontal
Short Horizontal
Net Width
U
Net
U
Not Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Width
Deduct
Width
Width
Width
Width
in
Deduct
in
Deduct
Deduct
Deduct
Deduct
in
in
in
in
in
T1 400.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
380.00
T2-T6
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
380.00-
280.00
T7-T10
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
280.00-
200.00
T11 200.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
192.50
T12 192.50-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
180.00
T13 180.00-
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
160.00
T14-T20
0.0000
-1
0.0000.
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
180.00-20.o0
T21 26.00-
0:0000
1
0.0000
0:75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
4.67
T22 4.67-0.00
0.0000
1
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.75
0.0000
0.76
Tower Section Geometry cont'd
Tower
Elevation
R
Leg
Connection
Type
Leg
Bolt Size
No.
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontai
Short
Horizontal
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size
No.
in
in
in
in
in
in
in
. T1400.00-
Flange
0.6250
5
0.6250
0
0.6260
0
0.6250
0
0.6250
0
0.6260
0
0.6250
0
380.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
T2-T6
_Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
380.00-
A325X
A325N
A325N
A325N
A325N
A325N
A325N
280.00
T7-T10
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
280.00-
A325X
A325N
A325N
A325N
A325N
A325N
A325N
200.00
T11200.00-
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
192.50
A325X
A325N
A325N
A325N
A325N
A325N
A325N
T12192.50-
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
180.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
T13180.00-
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
160.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
T14-T20
Flange
0.6250
5
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
0.6250
0
160.00-20.00
A325X
A325N
A325N
A325N
A325N
A325N
A325N
Page 17
Rigorous Structural Analysis Report- yerizon: 62713-Spain Tower July 17, 2015
CALTROP Corporation
Tower Leg Leg
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontai
Short
Elevation Connection
Horizontal
it Type
Bolt Size No.
Bog Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
in
in
in
in
in
in
in
T2120.00- Flange 0.6250 5
0.6250 0
0.6250 0
0.6250 0
0.6250 0
0.6250 0
0.6250 0
4.67 A325X
A325N
A325N
A325N
A325N
A325N
A325N
T22 4.67-0.00 Flange 0.6260 5
0.6250 0
0.6250 0
0.6250 0
0.6260 0
0.6250 0
0.6250 0
A325X
A325N
A325N
A325N
A325N
A325N
A325N
Guy Data
Guy
Guy
Guy
Initial
%
Guy
Guy
L„
Anchor
Anchor
Anchor
End
Elevation
Grade
Size
Tension
Modulus
Weight
Radius
Azimuth
Elevation
Fitting
Adj.
Effic/ency
it
K
ksi
p/f
ft
it
It
%
440.125
BS
A
13/16
8.00
10%
24000
1.390
505.20
250.00
0.0000
0.00
100%
B
13/16
8.00
10%
24000
1.390
505.20
250.00
0.0000
0.00
100%
C
13/16
8.00
10%
24000
1.390
605.20
250.00
0.0000
0.00
100%
397.25
EHS
A
11/16
5.00
10%
21000
1.000
467.80
250.00
0.0000
0.00
100%
B
11/16
5.00
16%
21000
1.000
467.80
250.00
0.0000
0.00
100%
C
11/16
5.00
10%
21000
1.000
467.80
250.00
0.0000
0.00
100%
339.667
BS
A
11/16
5.80
10%
24000
0.990
420.05
250.00
0.0000
0.00
100%
B
11116
5.80
10%
24000
0.990
420.05
250.00
0.0000
0.00
100%
C
11/16
5.80
10%
24000
0.990
420.05
250.00
0.0000
0.00
100%
279.667
BS
A
3/4
6.80
10%
24000
1.180
373.29
250.00
0.0000
0.00
100%
B
314
6.80
10%
24000
1.180
373.29
250.00
0.0000
0.00
100%
C
3/4
6.80
10%
24000
1.180
373.29
250.00
0.0000
0.00
100%
219.667
BS
A
11116
5.80
10%
24000
0.990
330.80
250.00
0.0000
0.00
100%
B
11/16
5.80
10%
24000
0.990
330.80
250.00
0.0000
0.00
100%
C
11/16
5.80
10%
24000
0.990
330.80
250.00
0.0000
0.00
100%
179.667
BS
A
13/16
7.20
9%
24000
1.390
305.78
250.00
0.0000
0.00
100%
B
13/16
7.20
9%
24000
1.390
305.78
250.00
0.0000
0.00
100%
C
13116
7.20
9%
24000
1.390
305.78
250.00
0.0000
0.00
100%
137.333
BS
A
13/16
7.20
9%
24000
1.390
283.02
250.00
0.0000
0.00
100%
B
13/16
7.20
9%
24000
1.390
283.02
250.00
0.0000
0.00
100%
C
13/16
7.20
9%
24000
1.390
283.02
260.00
0.0000
0.00
100%
70.3333
BS
A
13/16
7.20
9%
24000
1.390
257.31
250.00
0.0000
0.00
100%
B
13116
7.20
9%
24000
1.390
257.31
250.00
0.0000
0.00
100%
C
13116
7.20
9%
24000
1.390
267.31
250.00
0.0000
0.00
100%
Guy
Mount
Torque -Arm
Torque -Arm Torque -Arm
Torque -Arm Torque -Arm Torque -Arm Size
Elevation
Type
Spread
Leg Angle Style
Grade Type
ft
ft
440.125
Comer
397.25
Torque Arts
8.00
30.0000 Wing
A36 Solid Round 2 114
(36 ksi)
339.667
Comer
279.667
Comer
219.667
Comer
179.667
Comer
Page 18
Rigorous Structural Analysis Report- Verizon: 61713-Spain Tower
CALTROPCorporadon
July 17. 2015
Guy Mount Torque -Arm Torque -Arm Torque -Arm Torque -Arm Torque -Arm Torque -Arm Size
Elevation Type Spread Leg Angle Style Grade Type
it
70.3333 Comer
Guy
Data cont'd
-
.
Guy
Diagonal
Diagonal
Upper Diagonal
Lower Diagonal Is
Pull -Off
Pull -Off Type
Pull -Off Size
Elevation
Grade
Type
Size
Size Strap.
Grade
ft
440.13
A572-50
Solid Round
No
A36
Solid Round
1 114
(50 ksi)
(36 ksi)
397.25
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
339.67
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
279.67
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
219.67
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
179.67
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
137.33
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
70.33
A572-50
Solid Round
No
A36
Solid Round
1 1/4
(50 ksi)
(36 ksi)
Guy
Data cont'd
Guy
Cable
Cable
Cable
Cable
Tower
Tower
Tower
Tower
Elevation
Weight
Weight
Weight
Weight
Intercept
Intercept
Intercept
Intercept
A
B
C
D
A
B
C
D
it
K
K
K
K
B
it
R
/t
440.125
0.70
0.70
0.70
21.38
21.38
21.38
-
8.0
8.0
8.0 sedpulse
sedpulse
sec/pulse
397.25
0.47
0.47
0.47
21.07
21.07
21.07
7.9
7.9
7.9 sedpulse
=
sec/pulse
sedpulse
339.667
0.42
0.42
0.42
14.65
14.65
14.65
6.6
6.6
6.6 sedpulse
sedpulse
sedpulse
279.667
0.44
0.44
0.44
11.82
11.82
11.82
5.9
5.9
5.9 sedpulse
sedpulse
sedpulse
219.667
0.33
0.33
0.33
9.18
9.18
9.18
5.2
5.2
5.2 sec/pulse
sedpulse
sedpulse
179.667
0.43
0.43
0.43
8.88
8.88
8.88
5.1
5.1
5.1 sedpulse
sedpulse
sedpulse
Page 19
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17, 2015
CA6TR0P Corporation
Guy
Cable
Cable
Cable
Cable
Tower
Tower
Tower
Tower
Elevation
Weight
Weight
Weight
Weight
Intercept
Intercept
Intercept
Intercept
A
B
C
D
A
B
C
D
It
K
K
K
K
It
It
it
It
137.333
0.39
0.39
0.39
7.64
7.64
7.64
4.8
4.8
4.8 sedpulse
sedpulse
sedpulse
70.3333
0.36
0.36
0.36
6.35
6.35
6.35
4.4
4.4
4.4 sedpulse
sec/pulse
sedpulse
Guy Data. (cont'd)
Guy
Calc
Catc K,
Kr K.
Kr
K
Kr
Elevation
K
K
R
Single
Solid
Angles
Rounds
440.125
No
No
1
1
1
1
397.25
No
No 1
1 1
1
1
1
339.667
No
No
1
1
1
1
279.667
No
No
1
1
1
1
219.667
No
No
1
1
1
1
179.667
No
No
1
1
1
1
137.333
No
No
1
1
1
1
70.3333
No
No
1
1
1
1
Guy Data cont'd)
Torque -Arm
Put/ Off
Diagonal
Guy
Bolt Size
Number
Net Width
U
Bolt Size
Number
Net Width
U
Bolt Size
Number
Net Width
U
Elevation
in
Deduct
in
Deduct
in
Deduct
R
in
in
440.125
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
5
.0
A325N
A325N
A3
397.25
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0. 'Se--
b 0 -
0. 5
A325N
A325N
A325N
339.667
1.0000
1
0.0000
1
1.0000
1
0,0000
0.75
0.6250
0
0.0000
0.75
A325N
A325N
A325N
279.667
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0.6250
0
0.0000
0.75
A325N
A325N
219.667
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0.6260
0
0.0000
0.75
A325N
A325N
179.667
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0.6250
0
0.0000
0.75
A325N
A325N
137.333
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0.6250
0
0.0000
0.75
A325N
A325N
70.3333
0.0000
0
0.0000
1
0.6250
0
0.0000
0.75
0.6250
0
0.0000
0.75
A325N
A325N
Guy Pressures
Page 20
w
R
Z
wD
W
1
I
w w J J J J
OW>OmDOw>OW>OmDOWDow>ow D
N N N N n N N N N N N N N
JJ 3
b bmw. tOd...........NNNfI�NN
+ N N N N N N w
is
pme �oo'g
uwwwwwvJVJJJJJJJJJmm WW
O'�DmtO m!O �D J V J m m m mmmmVm�Vm�mmm 0'�
NVmmmm6mL�PAVVV
mmm oommmJJ ""m 'm +m �umm 66�
p PQVmm mmmPo00NN N10 m�OO,y M
a
m mmO.V (J (J 1J m ry
N N N m m J p
OOOM.Mmfo-W. ...WV4Pi bmw+++� B
L
J V ...........
m W w w m m 0
O OOOVN (NJry000� NIJ JC i.d
Nu�.i000>'p>u umiN���wimtrv�i���IJnu�
a
N N N m N N 0
0 ........ 0 0 0 .. 0 ......... O x N'd
0
m mmmmmmmm00000000000000
mmmJ Jmmmu�n pZ:
m m�&'apmmmmm JJA�m+ Jmm"� � m NNN Vmi m 0 0 0 a
O�mmP qm mmpma pm�W NNdmmmwNAAAJV ;>
..........
m m N Ili w N N m m A A P m........... 0
N ddm ......m m�(Oilm may,N. c, m mm(1��0 tO lO lO... .
m ONi P m m P m m m m m m 1�0 b NO (1� m m O p N N N N O
A A A W N m N m y m N m U pU A p N p L y p pp J j
NNN
W W W d m m w w 4Ji Omi T T w w Ww
W m W a
'GOj V t0 t_VD fWD V O C
W W V rn W rn rn N j
O W D O W D O W D O W D O W D O W D O W D O W D o
W W W rn rn rn OJ Ol W 0 0 0 W W W rn rn rn- 8- N N N
rn rn N OJ rn W t0 t0 (O t0 f0 (D (O lD f0 t0 t0 t0 OJ OD W O O O
rnrnrn aomm �
�
W W W W W W A A A A A A A A A A A A A A A A A
W W W rn N W O O O N N N A A rn O1 rn V V V W W
y N d
Y
N
0
V
O
M
d
N
N
D D D
< '1 '1+NO N OAO +AO �3 �O '1 -I
AW
OZ!ZIZ4T
m mMDN O�mO
m =tr,wlwD+mvDW m+ vDW +mVDfN �W+ y90
DD V° ° ' D Ky m
.i —
O O O O O O O O m m m m m m m m m m w m m m m D D D D D D D D
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
o O O O O 0 o O O O 0 0 0 0 0 0 0 O O 0 0 0 o O 0 0 0 o O O 0 i
D D D D D D D D D D D D D D D D D D D D D D D D
0 0 0 0 0 0 0 00000 0 0000 000 0 0 0 o 0 0 0 0 0 o i
N O O O O O O O V A V fWll m O W A+ W N N V V V + (p (p (O (p (O (p (p
N N N m m N Ol V W N O N V A O N O O N O N N N O) N N N N N N N
O O O O O O O p O O O O O O O O O O O O N N N O O O O O O O O l
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O t
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o a o o t
W N N N N N N +++++ + + + ++ N N N O) W W W W N N + f
O O O O O O O O O O O O O O p p O O O O O O O O O O O O N O O
O O O O O O O O O O O O O O p p O O O O O O O O O O O O O O O (
O O O O O O O O O O O O O O p p 0 O O O O O O O O O O O O O O (
O O O C
O O
N
P
.O
G
O O O O O O
O P p
'O O O
A N
OW
W A W T N +
OV + IV
N
tD
N
N
t01(
W N W
A +
N
W
N
W
N
+++++ +
++++
+++
+ +
+
71
+
+
+
+
+++++ +
o+ o
++++
0 0 0+
+++
o:-,+
i0 ut
m
io
io
i0
io
�
m ow
w oo a io
w i0
W N
W
W
W
W
(A
W++++ W
N W W N
N+ W
0 0
O O
0
O
0
O
0
O
0
O
0
O
0 0 0 0 0 O
O O O O O O
Coco
m000
O o o
O O O
+ +
+
+
+
+
+
O O
O O O +
O + +
f0 Ut
t0
t0
N
N
lD
t0
O O
O O
O
O
O
O
O
O
O
O
O
O
O O O+ - O
O O O O
O O O O
O O O O
O O O
000
0
o m
o
0
0
0
0
� ut ut ut ut
oAAo
oinC
A O)
A
A
A
A
A
N A A N
O) O O A
(n A A
O
O
O
A O
b
N
N
N
O
p
W N
A
+
N
+
+
A
N
A A
W +
+
+
N
+
+
+
N
N +
0
0
+
N O
O
O
O
N
N
O
O
O O
A O
O
O
O
O
O
O
O
O O
+ +
+
O
O
+
+
+
ppO
fWll O
O
O
O
(Vlt
N
O
O
O O
A o
0
o
O
O
O
O
O
o 0
+ + + o o O O + +
O A A W A W W A A A A
� y
S
t
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower
CALTROP Corporation
July 17, 2015
Description
Face Allow
Component
Placement
Face
Lateral
#
#
Clear
Wdth or Perimete
Weight
or
Shield
Type
Offset
Offset
Per
Spacing
Diameter r
Leg
R
in
(Frac FM
Row
in
in
pit
in
1 5/8
C
No
Ar (CaAa)
226.00 - 0.00
3.0000
0.5
2
1
1.9800
1.9800
1.04
(Verizon)
1 5/8
C
No
Ar (CaAa)
226.00 - 0.00
3.0000
0.5
6
3
1.9800
1.9800
1.04
(Verizon)
1 5/8
A
No
Ar (CaAa)
226.00 - 0.00
0.5000
-0.38
6
2
1.9800
1.9800
1.04
Feed Line/Linear Appurtenances Section Areas
Tower
Tower
Face
Aa
AF
CAAA
CAAA
Weight
Sectio
Elevation
In Face
Out Face
n
1t
ft2
It,
fe
ft
K
Lt
480.00-460.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
1.760
0.000
0.01
C
0.000
0.000
0.000
0.000
0.00
L2
460.00-440.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
1.982
0.000
0.01
C
0.000
0.000
0.000
0.000
0.00
L3
440.00-420.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
4.202
0.000
0.02
C
0.000
0.000
0.000
0.000
0.00
L4
420.00-400.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
8.180
0.000
0.04
C
0.000
0.000
0.000
0.000
0.00
T1
400.00-380.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
10.160
0.000
0.05
C
0.000
0.000
0.000
0.000
0.00
T2
380.00-360.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
12.713
0.000
0.06
C
0.000
0.000
0.000
0.000
0.00
T3
360.00-340.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
18.356
0.000
0.09
C
0.000
0.000
0.000
0.000
0.00
- T41,
-'340.00,-320.00
A
0.000
0.000
0.000
0.000
0.00
< •-
B
0.000
0.000
20.780
0.000
0.10
`
C
0.000
0.000
0.000
0.000
0.00
' T5
320.00-300.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
20.780
0.000
0.10
C
0.000
0.000
0.000
0.000
0.00
T6
300.00-280.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
21.221
0.000
0.10
C
0.000
0.000
0.000
0.000
0.00
T7
280.00-260.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
22.040
0.000
0.11
C
0.000
0.000
0.000
0.000
0.00
T8
260.00-240.00
A
0.000
0.000
0.000
0.000
0.00
B
0.000
0.000
22.216
0.000
0.11
C
0.000
0.000
0.000
0.000
0.00
T9
240.00-220.00
A
0.000
0.000
7.128
0.000
0.04
B
0.000
0.000
24.150
0.000
0.12
C
0.000
0.000
14.256
0.000
0.07
T10
220.00-200.00
A
0.000
0.000
23,760
0.000
0.12
B
0.000
0.000
24.500
0.000
0.12
Page 23
N
N
A
N
Oo V T fly A W N+ A W N+
O
N N W W W W W A A A A A
m N O N A Of Oo O N A T 00
0 0 0 0 0 0 0 0 0 0 0 o
m
O O O AO
O O O O O O O O
j
0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0
+o 00o
T�
io ao io awain oin
oowJwwmw mom
T
VI .� � UI (T m W O fDm
o.
r
+o666p66
�
N V N O N
j
n
O T W V O
W Ili V V N A A W Oo W W A
fD
3
'S
+ 0 0 0 O
O
m m W( O m w 0 N w rn
K
1
N
LLLLL6666066
C
N m W K)V 6 V N E O N fnp L
m M V V N A A W m W W A
N
y
O
{p
A O O O 00 O O O O N O
m o c O O o o c O O to c
ET,J y
' a
O O o o O o 0 0 0 0 0
ip N A
o
A O O O O N A W W (O
O
O O O O O O
y
A
a
O W> O W D O W D O W D O W D O W D O W D O W D O W D O W D O W D O W D O
a
m
�
m
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O p O O O Ov
O p O p O p p O O ............ O p O O O O ....... O O O
a
q
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
N
W
a"
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n^
0 0 0 0 0 0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o c o 0 0 0 0 o
D
y
W W W A ffaa Ol (D OD (O Oo t0 W tD W W V OJ V O M V O Oo Ili O (li W T W N
A+bo A
t0 V W O t0 t0 O V p� O V O O V rn V O A W A J Qp A V W A O W W + O W Ol O
n y
W A V Y tp W O W O O W O O W O+ W O O W A O W O O W O O OJ O V W N W W W
N
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 o
c0
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
O A IJ A 4N (J fll tP (.� <!1 tl1 Cu tlt 41 W fT fT W UI fll W N N W N (T N N tJ O CJ + O + W
�
S
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower
CALTROP Corporation
Section
Elevation
R
CPx
in
CPz
in
CPx
Ice
in
CPz
Ice
in
T9
240.00-220.00
-0.7765
0.5871
-0.7765
0.5871
T10
220.00-200.00
-2.8815
2.4405
-2.8815
2.4405
T11
200.00-192.50
-2.9746
1.5884
-2.9746
1.5884
T12
192.50-180.00
-3.5157
-0.2502
-3.5157
-0.2502
T13
180.00-160.00
-2.9448
-0.6292
-2.9448
-0.6292
T14
160.00-140.00
-2.6360
-0.8289
-2.6360
-0.8289
T15
140.00-120.00
-2.6313
-0.8274
-2.6313
-0.8274
T16
120.00-100.00
-2.6421
-0.8185
-2.6421
-0.8185
T17
100.00-80.00
-2.5990
-0.7986
-2.5990
-0.7986
T18
80.00-60.00
-2.5886
-0.7940
-2.5886
-0.7940
T19
60.00-40.00
-2.5933
-0.7955
-2.5933
-0.7955
T20
40.00-20.00
-2.5933
-0.7955
-2.5933
-0.7955
T21
20.00-4.67
-2.5921
-0.7951
-2.5921
-0.7951
T22
4.67-0.00
-1.8487
-0.5173
-1.8487
-0.5173
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
Ka
No Ice
&
Ice
L1
18
5/8
460.00 -
0.6000
0.6000
480.00
L2
18
5/8
440.00 -
0.6000
0.6000
460.00
L2
23
7/8
440.00 -
0.6000
0.6000
442.00
L3
14
718
420.00-
0.6000
0.6000
422.00
L3
18
5/8
420.00-
0.6000
0.6000
440.00
0
23
7/8
420.00-
0.6000
0.6000
440.00
L4
14
7/8
400.00-
0.6000
0.6000
420.00
` L4
16
1 518
400.00-
0.6000
0.6000
410.00
L4
18
5/8
400.00-
0.6000
0.6000
420.00
L4
23
7/8
400.00-
0.6000
0.6000
420.00
Tt
14
718
380.00-
0.6000
0.6000
400.00
T1
16
1 518
380.00-
0.6000
0.6000
400.00
T1
18
5/8
380.00-
0.6000
0.6000
400.00
T1
23
7/8
380.00-
0.6000
0.6000
400.00
T2
14
7/8
360.00-
0.6000
0.6000
380.00
T2
16
1 518
360.00-
0.6000
0.6000
380.00
T21
181
5181
360.00-
0.6000
0.6000
Page 25
July 17, 2015
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K,
Ice
380.00
T2
22
7/8
360.00-
0.6000
0.6000
370.00
T2
23
7/8
360.00-
0.6000
0.6000
380.00
T2
24
7/8
360.00-
0.6000
0.6000
373.00
T3
13
1 5/8
340.00-
0.6000
0.6000
350.00
T3
14
7/8
340.00-
0.6000
0.6000
360.00
T3
16
1 5/8
340.00-
0.6000
0.6000
360.00
T3
18
518
340.00-
0.6000
0.6000
360.00
T3
21
718
340.00-
0.6000
0.6000
356.00
T3
22
7/8
340.00-
0.6000
0.6000
360.00
T3
23
7/8
340.00-
0.6000
0.6000
360.00
T3
24
7/8
340.00-
0.6000
0.6000
360.00
T4
13
1 5/8
320.00-
0.6000
0.6000
340.00
T4
14
718
320.00-
0.6000
0.6000
340.00
T4
16
1 5/8
320.00-
0.6000
0.6000
340.00
T4
18
5/8
320.00-
0.6000
0.6000
340.00
T4
21
7/8
320.00-
0.6000
0.6000
340.00
T4
22
7/8
320.00-
0.6000
0.6000
340.00
T4
23
7/8
320.00-
0.6000
0.6000
340.00
T4
24
7/8
320.00-
0.6000
0.6000
340.00
T5
13
1 5/8
300.00-
0.6000
0.6000
320.00
T5
14
7/8
300.00-
0.6000
0.6000
320.00
T5
16
1 5/8
300.00-
0.6000
0.6000
320.00
TS
18
518
300.00-
0.6000
0.6000
320.00
T5
21
7/8
300.00-
0.6000
0.6000
320.00
T5
22
7/8
300.00-
0.6000
0.6000
320.00
T5
23
7/8
300.00-
0.6000
0.6000
320.00
T5
24
7/8
300.00-
0.6000
0.6000
320.00
T6
13
1 5/8
280.00 -
0.6000
0.6000
300.00
T6
14
7/8
280.00 -
0.6000
0.6000
Page 26
July 17. 2015
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
300.00
T6
16
1 618
280.00-
0.6000
0.6000
300.00
T6
18
6/8
280.00-
0.6000
0.6000
300.00
T6
20
LDF4-50A (112 FOAM)
280.00-
0.6000
0.6000
287.00
T6
21
7/8
280.00-
0.6000
0.6000
300.00
T6
22
7/8
280.00-
0.6000
0.6000
300.00
T6
23
7/8
280.00-
0.6000
0.6000
300.00
T6
24
718
280.00-
0.6000
0.6000
300.00
T7
13
1 5/8
260.00-
0.6000
0.6000
280.00
T7
14
7/8
260.00-
0.6000
0.6000
280.00
T7
16
1 5/8
260.00-
0.6000
0.6000
280.00
T7
18
5/8
260.00-
0.6000
0.6000
280.00
T7
20
LDF4-50A (1/2 FOAM)
260.00-
0.6000
0,6000
280.00
T7
21
7/8
260.00-
0.6000
0.6000
280.00
T7
22
7/8
260.00-
0.6000
0.6000
280.00
T7
23
7/8
260.00-
0.6000
0.6000
280.00
T7
24
718
260.00-
0.6000
0.6000
280.00
T8
13
1 5/8
240.00-
0.6000
0.6000
260.00
T8
- ,14
718
240.00-
0.6000
0.6000
260.00
T8
- _ ; 16
1 5/8
240.00-
0.6000
0.6000
260.00
T8
17
518
240.00-
0.6000
0.6000
242.00
T8
18
5/8
240.00-
0.6000
0.6000
260.00
T8
20
LDF4-60A(1/2 FOAM)
240.00-
0.6000
0.6000
260.00
T8
21
7/8
240.00-
0.6000
0.6000
260.00
T8
22
7/8
240.00-
0.6000
0.6000
260.00
T8
23
718
240.00-
0.6000
0.6000
260.00
T8
24
7/8
240.00-
0.6000
0.6000
260.00
T9
13
1 5/8
220.00 -
0.6000
0.6000
240.00
T9
14
7/8
220.00 -
0.6000
0.6000
240.00
T9
15
LDFl-50A(1/4 FOAM)
220.00-
0.6000
0.6000
Page 27
July 17. 2015
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
230.00
T9
16
1 5/8
220.00-
0.6000
0.6000
240.00
T9
17
5/8
220.00-
0.6000
0.6000
240.00
T9
18
5/8
220.00-
0.6000
0.6000
240.00
T9
20
LDF4-50A (112 FOAM)
220.00-
0.6000
0.6000
240.00
T9
21
7/8
220.00-
0.6000
0.6000
240.00
T9
22
7/8
220.00-
0.6000
0.6000
240.00
T9
23
7/8
220.00-
0.6000
0.6000
240.00
T9
24
7/8
220.00-
0.6000
0.6000
240.00
T9
32
1 5/8
220.00-
0.6000
0.6000
226.00
T9
33
1 5/8
220.00-
0.6000
0.6000
226.00
T9
34
1 518
220.00-
0.6000
0.6000
226.00
T9
35
1 5/8
220.00-
0.6000
0.6000
226.00
T10
13
1 5/8
200.00-
0.6000
0.6000
220.00
T10
14
7/8
200.00-
0.6000
0.6000
220.00
T10
15
LDFl-50A(1/4 FOAM)
200.00-
0.6000
0.6000
220.00
T10
16
1 5/8
200.00-
0.6000
0.6000
220.00
T10
17
5/8
200.00-
0.6000
0.6000
220.00
T10
18
5/8
200.00-
0.6000
0.6000
220.00
T10
20
LDF4-50A (112 FOAM)
200.00-
0.6000
0.6000
220.00
T1 O
21
7/8
200.00-
0.6000
0.6000
220.00
T10
22
7/8
200.00-
0.6000
0.6000
220.00
T10
23
7/8
200.00-
0.6000
0.6000
220.00
T10
24
7/8
200.00-
0.6000
0.6000
220.00
T10
26
1 5/8
200.00-
0.6000
0.6000
206.00
T10
27
1 5/8
200.00-
0.6000
0.6000
206.00
T10
28
1 6/8
200.00-
0.6000
0.6000
206.00
T10
29
1 518
200.00-
0.6000
0.6000
206.00
T10
30
1 5/8
200.00-
0.6000
0.6000
206.00
T10
31
1 1/4
200.00-
0.6000
0.6000
Page 28
July 17, 2015
+nr � v = ? ✓ ` t
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower
CAL TROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
206.00
T10
32
1 5/8
200.00-
0.6000
0.6000
220.00
T10
33
1 518
200.00-
0.6000
0.6000
220.00
T10
34
1 5/8
200.00-
0.6000
0.6000
220.00
T10
35
1 518
200.00-
0.6000
0.6000
220.00
T11
1
1 5/8
192.50-
0.6000
0.6000
195.00
T11
2
1 518
192.50 -
0.6000
0.6000
195.00
T11
3
1 5/8
192.50-
0.6000
0.6000
195.00
T11
4
1 5/8
192.50-
0.6000
0.6000
195.00
T11
5
1 5/8
192.50-
0.6000
0.6000
195.00
T11
6
318
192.50-
0.6000
0.6000
195.00
T11
7
3/8
192.50 -
0.6000
0.6000
195.00
T11
8
7/8
192.50-
0.6000
0.6000
195.00
T11
13
1 518
192.50-
0.6000
0.6000
200.00
T11
14
718
192.50-
0.6000
0.6000
200.00
T11
15
LOFl-50A(1/4 FOAM)
192.50-
0.6000
0.6000
200.00
T11
16
1 518
192.50-
0.6000
0.6000
200.00
T11
17
5/8
192.50-
0.6000
0.6000
200.00
T11
18
518
192.50-
0.6000
0.6000
200.00
' T11
i•• '20
•LDF4-50A(1/2 FOAM)
192.50-
0.6000
0.6000
200.00
T11
21
718
192.50-
0.6000
0.6000
200.00
T11
22
7/8
192.50-
0.6000
0.6000
200.00
T11
23
7/8
192.50-
0.6000
0.6000
200.00
T11
24
7/8
192.50-
0.6000
0.6000
200.00
T11
26
1 5/8
192.50-
0.6000
0.6000
200.00
T11
27
1 5/8
192.50-
0.6000
0.6000
200.00
T11
28
1 5/8
192.50-
0.6000
0.6000
200.00
T11
29
15/8
192.50-
0.6000
0.6000
200.00
T11
30
1 5/8
192.50-
0.6000
0.6000
200.00
T11
31
1 114
192.50-
0.6000
0.6000
Page 29
July 17, 2015
3
I
O
O
0
0
0 0
0
0 0
0
0
0
0
0
0
0 0
O
0
0
0
0
0
0
0
0
0
0 0
0
0
0
0
0 0
0
0 0
0
0
0
0
0
0
0 0
0
0
0
0
0
0
0
0
0
0
0 0
O
m
o
m
0
m
0
m
0 0
m m
0
m
o O
m m
o
m
0
m
0
m
0
m
0
m
0
m
0 0
m m
0
m
0
m
0
m
0
m
0
m
0
m
0
m
0
m
0
m
0
m
0 0
m m
Y=
0
0
0
0
0 0
0
0 0
0
0
0
0
0
0
0 0
0
0
0
0
0
0
0
0
0
0
0 0
0
0
0
0
o O
O
0 0
0
0
0
0
0
0
0 0
0
0
0
0
0
0
0
0
0
0
0 0
0
o
0
0
0
O 0
0
0 0
0
0
0
0
0
0
0 0
0
0
0
0
0
0
0
0
0
0
0
m
m
m
m
m m
m
m m
m
m
m
m
m
m
m m
m
m
m
m
m
m
m
m
m
m
m m
2
o
o o
0 o
o
o o
o
o o
o
o o
o o
o o
o o
o
o
o o
o
o
o
o
o
y
O O
O O O
O
O O O
O N O
N O N
O N O
N O N
O
N O
N O N
O
N O N
O N O N
O
N O N
O
N O
N O
N O N
O N
O N
O N
O h
O N O
C C
0 N
0 N 0
N 0 N 0
0 N O
N 0 nj
O N O
N O N
O
N O
N O 'j
O N O N
O nj O nj
O N O N
O
N O
nj O
N O N
O N
O N
O N
O N
O O
J m>
E-
O N
N m
O N O
N— N
N O N O
m N m N
G m C
m m
m O m
m
O O! O
m m
T O O)
m
O
m
m O
m
m O T
m
0 W O m
m m
O m 0 m
m m
O m 0 O1
m m
O
m
T O
m
m 0
m
W O W
m
O m
m
C m
m
O A
m
O m
m
Om 0
m m
co
m
m
m
m
m m
m
m m
m
m
w
m
m
m m
m
m
m
m
m
m
m
m
m
m a
n
i5
4-3 N
N
�5 L?s
M
c>
n
n
O
in
in
O
n
n
r
n
in
N
LL
LL
a
N
O
a
y
N
'
N
Q
0
0
0
�
G Z
J D
N
LL m
N N
N
N N
N
N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N
N
N N
3 o
F-
F
F
F-
F- F
F
F F-
F
F-
F-
F
F
F
F F
F
F
F
F
F
F
F
F
F
F
F F
U
Q
F• �
Rigorous Structural Analysis Report- 4erizon: 61713-Spain Tower
CAL7ROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
E/ev.
Ka
No Ice
K.
Ice
192.50
T12
32
1 5/8
180.00-
0.6000
0.6000
192.50
T12
33
1 5/8
180.00-
0.6000
0.6000
192.50
T12
34
1 518
180.00-
0.6000.
0.6000
192.50
T12
35
1 5/8
180.00-
0.6000
0.6000
192.50
T13
1
1 5/8
160.00-
0.6000
0.6000
180.00
T13
2
1 518
160.00-
0.6000
0.6000
180.00
T13
3
1 5/8
160.00-
0.6000
0.6000
180.00
T13
4
1 5/8
160.00-
0.6000
0.6000
180.00
T13
5
1 5/8
160.00-
0.6000
0.6000
180.00
T13
6
318
160.00-
0.6000
0.6000
180.00
T13
7
318
160.00-
0.6000
0.6000
180.00
T13
8
7/8
160.00-
0.6000
0.6000
180.00
T13
10
1 5/8
160.00-
0.6000
0.6000
172.50
T13
11
1 5/8
160.00-
0.6000
0.6000
172.50
T13
12
39mm Hybrid (1.5351n)
160.00-
0.6000
0.6000
172.50
T13
13
1 518
160.00-
0.6000
0.6000
180.00
T13
14
7/8
160.00-
0.6000
0.6000
180.00
T13
15
LDFi-50A (114 FOAM)
160.00-
0.6000
0.6000
180.00
T13
16
1 5/8
160.00-
0.6000
0.6000
180.00
T13
17
518
160.00-
0.6000
0.6000
180.00
T13
18
5/8
160.00-
0.6000
0.6000
180.00
T13
20
LDF4-50A (1/2 FOAM)
160.00-
0.6000
0.6000
180.00
T13
21
7/8
160.00-
0.6000
0.6000
180.00
T13
22
7/8
160.00-
0.6000
0.6000
180.00
T13
23
7/8
160.00-
0.6000
0.6000
180.00
T13
24
7/8
160.00-
0.6000
0.6000
180.00
T13
26
1 5/8
160.00-
0.6000
0.6000
180.00
T13
27
1 5/8
160.00-
0.6000
0.6000
180.00
T13
28
1518
160.00-
0.6000
0.6000
Page 31
July 17, 2015
Rigorous Structural Analysis Report- Verizon:62713-Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
Ka
Ice
180.00
T13
29
1 5/8
160.00-
0.6000
0.6000
180.00
T13
30
1 518
160.00-
0.6000
0.6000
180.00
T13
31
1 1/4
160.00-
0.6000
0.6000
180.00
T13
32
1 518
160.00-
0.6000
0.6000
180.00
T13
33
1 518
160.00-
0.6000
0.6000
180.00
T13
34
1 518
160.00-
0.6000
0.6000
180.00
T13
35
1 518
160.00-
0.6000
0.6000
180.00
T14
1
1 5/8
140.00-
0.6000
0.6000
160.00
T14
2
1 5/8
140.00-
0.6000
0.6000
160.00
T14
3
1 518
140.00-
0.6000
0.6000
160.00
T14
4
1 5/8
140.00-
0.6000
0.6000
160.00
T14
5
1 5/8
140.00-
0.6000
0.6000
160.00
T14
6
3/8
140.00-
0.6000
0.6000
160.00
T14
7
3/8
140.00-
0.6000
0.6000
160.00
T14
8
7/8
140.00-
0.6000
0.6000
160.00
T14
10
1 5/8
140.00-
0.6000
0.6000
160.00
T14
11
1 518
140.00-
0.6000
0.6000
160.00
T14
12
39mm Hybrid (1.5351n)
140.00-
0.6000
0.6000
160.00
T14
13
1 5/8
140.00-
0.6000
0.6000
160.00
T14
14
7/8
140.00-
0.6000
0.6000
160.00
T14
15
LOFl-50A (1/4 FOAM)
140.00-
0.6000
0.6000
160.00
T14
16
1 5/8
140.00-
0.6000
0.6000
160.00
T14
17
5/8
140.00-
0.6000
0.6000
160.00
T14
18
5/8
140.00-
0.6000
0.6000
160.00
T14
20
LDF4-50A(1/2 FOAM)
140.00-
0.6000
0.6000
160.00
T14
21
718
140.00-
0.6000
0.6000
160.00
T14
22
7/8
140.00-
0.6000
0.6000
160.00
T14
23
7/8
140.00-
0.6000
0.6000
160.00
T14
24
7/8
140.00-1
0.60001
0.6000
Page 32
July 17, 2015
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Descdption
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
160.00
T14
26
1 5/8
140.00-
0.6000
0.6000
160.00
T14
27
1 5/8
140.00-
0.6000
0.6000
160.00
T14
28
1 518
140.00-
0.6000
0.6000
160.00
T14
29
1 5/8
140.00-
0.6000
0.6000
160.00
T14
30
1 518
140.00-
0.6000
0.6000
160.00
T14
31
1 114
140.00-
0.6000
0.6000
160.00
T14
32
1 5/8
140.00-
0.6000
0.6000
160.00
T14
33
1 5/8
140.00-
0.6000
0.6000
160.00
T14
34
1 5/8
140.00-
0.6000
0.6000
160.00
T14
35
1 518
140.00-
0.6000
0.6000
160.00
T15
1
1 518
120.00 -
0.6000
0.6000
140.00
T15
2
1 5/8
120.00 -
0.6000
0.6000
140.00
T15
3
1 5/8
120.00 -
0.6000
0.6000
140.00
T15
4
1 5/8
120.00 -
0.6000
0.6000
140.00
T15
5
1 5/8
120.00 -
0.6000
0.6000
140.00
T16
6
3/8
120.00 -
0.6000
0.6000
140.00
T15
7
3/8
120.00 -
0.6000
0.6000
140.00
T15
8
718
120.00 -
0.6000
0.6000
140.00
T15
10
1 518
120.00 -
0.6000
0.6000
•
''
140.00
T15
' ', 11
1 5/8
120.00 -
0.6000
0.6000
140.00
T15
12
39mm Hybrid (1.535in)
120.00 -
0.6000
0.6000
140.00
T15
13
1 5/8
120.00 -
0.6000
0.6000
140.00
T15
14
7/8
120.00 -
0.6000
0.6000
140.00
T15
15
LDF1-50A (1/4 FOAM)
120.00 -
0.6000
0.6000
140.00
T15
16
15/8
120.00-
0.6000
0.6000
140.00
T15
17
5/8
120.00 -
0.6000
0.6000
140.00
T15
18
5/8
120.00 -
0.6000
0.6000
140.00
T15
20
LDF4-50A (1/2 FOAM)
120.00 -
0.6000
0.6000
140.00
T15
21
7/8
120.00 -
0.6000
0.6000
Page 33
July 17. 2015
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
140.00
T15
22
7/8
120.00-
0.6000
0.6000
140.00
T15
23
7/8
120.00-
0.6000
0.6000
140.00
T15
24
7/8
120.00-
0.6000
0.6000
140.00
T15
26
1 518
120.00-
0.6000
0.6000
140.00
T15
27
1 518
120.00-
0.6000
0.6000
140.00
T15
28
1 5/8
120.00-
0.6000
0.6000
140.00
T15
29
1 5/8
120.00-
0.6000
0.6000
140.00
T15
30
1 5/8
120.00-
0.6000
0.6000
140.00
T15
31
11/4
120.00-
0.6000
0.6000
140.00
T15
32
1 5/8
120.00-
0.6000
0.6000
140.00
T15
33
1 5/8
120.00-
0.6000
0.6000
140.00
T15
34
1 518
120.00-
0.6000
0.6000
140.00
T15
35
1 518
120.00-
0.6000
0.6000
140.00
T16
1
1 6/8
100.00-
0.6000
0.6000
120.00
T16
2
1 5/8
100.00-
0.6000
0.6000
120.00
T16
3
1 5/8
100.00-
0.6000
0.6000
120.00
T16
4
1 5/8
100.00-
0.6000
0.6000
120.00
T16
5
1 5/8
100.00-
0.6000
0.6000
120.00
T16
6
3/8
100.00-
0.6000
0.6000
120.00
T16
7
3/8
100.00-
0.6000
0.6000
120.00
T16
8
7/8
100.00-
0.6000
0.6000
120.00
T16
9
LDF2-50A (3/8 FOAM)
100.00-
0.6000
0.6000
116.00
T16
10
1 518
100.00-
0.6000
0.6000
120.00
T16
11
1 5/8
100.00-
0.6000
0.6000
120.00
T16
12
39mm Hybrid (1.535in)
100.00-
0.6000
0.6000
120.00
T16
13
1 5/8
100.00-
0.6000
0.6000
120.00
T16
14
7/8
100.00-
0.6000
0.6000
120.00
T16
15
LDFl-50A(1/4 FOAM)
100.00-
0.6000
0.6000
120.00
T16
16
1 5/8
100.00-
0.6000
0.6000
Page 34
July 17, 2015
Rigorous Structural Analysis Report- Verizon: 62713 -Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
Ka
No Ice
K.
Ice
120.00
T16
17
5/8
100.00-
0.6000
0.6000
120.00
T16
18
5/8
100.00-
0.6000
0.6000
120.00
T16
19
LDF1-50A(1/4 FOAM)
100.00-
0.6000
0.6000
104.00
T16
20
LDF4-50A(1/2 FOAM)
100.00-
0.6000
0.6000
120.00
T16
21
7/8
100.00-
0.6000
0.6000
120.00
T16
22
7/8
100.00-
0.6000
0.6000
120.00
T16
23
718
100.00-
0.6000
0.6000
120.00
T16
24
7/8
100.00-
0.6000
0.6000
120.00
T16
26
1 5/8
100.00-
0.6000
0.6000
120.00
T16
27
1518
100.00-
0.6000
0.6000
120.00
T16
28
1 518
100.00-
0.6000
0.6000
120.00
T16
29
1 5/8
100.00-
0.6000
0.6000
120.00
T16
30
1 5/8
100.00-
0.6000
0.6000
120.00
T16
31
11/4
100.00-
0.6000
0.6000
120.00
T16
32
1 5/8
100.00-
0.6000
0.6000
120.00
T16
33
1 5/8
100.00-
0.6000
0.6000
120.00
T16
34
1 518
100.00-
0.6000
0.6000
120.00
T16
35
1 518
100.00-
0.6000
0.6000
'+
120.00
' T17
1
1 5/8
80.00 -
0.6000
0.6000
100.00
' T17
2
1 518
80.00 -
0.6000
0.6000
100.00
T17
3
1 5/8
80.00 -
0.6000
0.6000
100.00
T17
4
1 5/8
80.00 -
0.6000
0.6000
100.00
T17
5
1 5/8
80.00 -
0.6000
0.6000
100.00
T17
6
3/8
80.00 -
0.6000
0.6000
100.00
T17
7
3/8
80.00 -
0.6000
0.6000
100.00
T17
8
7/8
80.00 -
0.6000
0.6000
100.00
T17
9
LDF2-50A (3/8 FOAM)
80.00 -
0.6000
0.6000
100.00
T17
10
1 5/8
80.00 -
0.6000
0.6000
100.00
T17
11
1 5/8
80.00 -
0.6000
0.6000
Page 35
July 17, 2015
Rigorous Structural Analysis Report- Perizon: 62713-Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Descripdon
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
100.00
T17
12
39mm Hybrid (1.535h)
80.00-
0.6000
0.6000
100.00
T17
13
1 518
80.00-
0.6000
0.6000
100.00
T17
14
7/8
80.00-
0.6000
0.6000
100.00
T17
15
LDF1-50A(1/4 FOAM)
80.00-
0.6000
0.6000
100.00
T17
16
1 5/8
80.00-
0.6000
0.6000
100.00
T17
17
518
80.00-
0.6000
0.6000
100.00
T17
18
5/8
80.00-
0.6000
0.6000
100.00
T17
19
LDFl-50A (1/4 FOAM)
80.00-
0.6000
0.6000
100.00
T17
20
LDF4-50A (112 FOAM)
80.00-
0.6000
0.6000
100.00
T17
21
7/8
80.00-
0.6000
0.6000
100.00
T17
22
7/8
80.00-
0.6000
0.6000
100.00
T17
23
7/8
80.00-
0.6000
0.6000
100.00
T17
24
7/8
80.00-
0.6000
0.6000
100.00
T17
25
LDF4-50A (1/2 FOAM)
80.00-
0.6000
0.6000
97.00
T17
26
1 518
80.00-
0.6000
0.6000
100.00
T17
27
1 5/8
80.00-
0.6000
0.6000
100.00
T17
28
1 518
80.00-
0.6000
0.6000
100.00
T17
29
1 518
80.00-
0.6000
0.6000
100.00
T17
30
1 5/8
80.00-
0.6000
0.6000
100.00
T17
31
11/4
80.00-
0.6000
0.6000
100.00
T17
32
1 5/8
80.00-
0.6000
0.6000
100.00
T17
33
1 5/8
80.00-
0.6000
0.6000
100.00
T17
34
1 5/8
80.00-
0.6000
0.6000
100.00
T17
35
1 5/8
80.00-
0.6000
0.6000
100.00
T18
1
1 5/8
60.00 -
0.6000
0.6000
80.00
T18
2
1 5/8
60.00 -
0.6000
0.6000
80.00
T18
3
1 518
60.00 -
0.6000
0.6000
80.00
T18
4
1 5/8
60.00 -
0.6000
0.6000
80.00
T18
5
1 518
60.00 -
0.6000
0.6000
Page 36
July 17. 2015
1 1 �
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporadon
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
80.00
T18
6
3/8
60.00-
0.6000
0.6000
80.00
T18
7
318
60.00-
0.6000
0.6000
80.00
T18
8
7/8
60.00-
0.6000
0.6000
80.00
T18
9
LDF2-50A (3/8 FOAM)
60.00-
0.6000
0.6000
80.00
T18
10
15/8
60.00-
0.6000
0.6000
80.00
T18
11
1 5/8
60.00-
0.6000
0.6000
80.00
T18
12
39mm Hybrid (1.535in)
60.00-
0.6000
0.6000
80.00
T18
13
1 5/8
60.00-
0.6000
0.6000
80.00
T18
14
7/8
60.00-
0.6000
0.6000
80.00
T18
15
LDFI-50A (1/4 FOAM)
60.00-
0.6000
0.6000
80.00
T18
16
1 518
60.00-
0.6000
0.6000
80.00
T18
17
5/8
60.00-
0.6000
0.6000
80.00
T18
18
5/8
60.00-
0.6000
0.6000
80.00
T18
19
LDFl-50A (1/4 FOAM)
60.00-
0.6000
0.6000
80.00
T18
20
LDF4-50A (1/2 FOAM)
60.00-
0.6000
0.6000
80.00
T18
21
7/8
60.00-
0.6000
0.6000
80.00
T18
22
7/8
60.00-
0.6000
0.6000
80.00
T18
23
7/8
60.00-
0.6000
0.6000
80.00
T18
24
718
60.00-
0.6000
0.6000
80.00
T18.
25',
LDF4-50A(1/2 F0AM)
60.00-
0.6000
0.6000
80.00
T18
26
1 618
60.00-
0.6000
0.6000
80.00
T18
27
1 5/8
60.00-
0.6000
0.6000
80.00
T18
28
1518
60.00-
0.6000
0.6000
80.00
T18
29
1 5/8
60.00-
0.6000
0.6000
80.00
T18
30
15/8
60.00-
0.6000
0.6000
80.00
T18
31
11/4
60.00-
0.6000
0.6000
80.00
T18
32
1 5/8
60.00-
0.6000
0.6000
80.00
T18
33
1 5/8
60.00 -
0.6000
0.6000
80.00
T18
34
15/8
60.00--
0.6000
0.6000
Page 37
July 17. 2015
Rigorous Structural Analysis Report- Perizon: 62713 -Spain Traver
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
K.
Ice
80.00
T18
35
1 5/8
60.00-
0.6000
0.6000
80.00
T19
1
1 518
40.00-
0.6000
0.6000
60.00
T19
2
1 518
40.00-
0.6000
0.6000
60.00
T19
3
1 5/8
40.00-
0.6000
0.6000
60.00
T19
4
1 518
40.00-
0.6000
0.6000
60.00
T19
5
1 5/8
40.00-
0.6000
0.6000
60.00
T19
6
318
40.00-
0.6000
0.6000
60.00
T19
7
318
40.00-
0.6000
0.6000
60.00
T19
8
7/8
40.00-
0.6000
0.6000
60.00
T19
9
LDF2-50A (318 FOAM)
40.00-
0.6000
0.6000
60.00
T19
10
1 5/8
40.00-
0.6000
0.6000
60.00
T19
11
1 518
40.00-
0.6000
0.6000
60.00
T19
12
39mm Hybrid (1.535in)
40.00-
0.6000
0.6000
60.00
T19
13
1 518
40.00-
0.6000
0.6000
60.00
T19
14
718
40.00-
0.6000
0.6000
60.00
T19
15
LDF1-50A(114 FOAM)
40.00-
0.6000
0.6000
60.00
T19
16
1 5/8
40.00-
0.6000
0.6000
60.00
T19
17
518
40.00-
0.6000
0.6000
60.00
T19
18
518
40.00-
0.6000
0.6000
60.00
T19
19
LDFl-50A(1/4 FOAM)
40.00-
0.6000
0.6000
60.00
T19
20
LDF4-50A (1/2 FOAM)
40.00-
0.6000
0.6000
60.00
T19
21
7/8
40.00-
0.6000
0.6000
60.00
T19
22
718
40.00-
0.6000
0.6000
60.00
T19
23
718
40.00-
0.6000
0.6000
60.00
T19
24
7/8
40.00-
0.6000
0.6000
60.00
T19
25
LDF4-50A (1/2 FOAM)
40.00-
0.6000
0.6000
60.00
T19
26
1 5/8
40.00-
0.6000
0.6000
60.00
T19
27
1 5/8
40.00-
0.6000
0.6000
60.00
T19
28
1 518
40.00-
0.6000
0.6000
Page 38
July 17, 2015
1 � _
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Bev.
Ke
No Ice
Ka
Ice
60.00
T19
29
1 5/8
40.00-
0.6000
0.6000
60.00
T19
30
1 5/8
40.00-
0.6000
0.6000
60.00
T19
31
11/4
40.00-
0.6000
0.6000
60.00
T19
32
15/8
40.00-
0.6000
0.6000
60.00
T19
33
1 5/8
40.00-
0.6000
0.6000
60.00
T19
34
1 5/8
40.00-
0.6000
0.6000
60.00
T19
35
1 5/8
40.00-
0.6000
0.6000
60.00
T20
1
1 5/8
20.00-
0.6000
0.6000
40.00
T20
2
1 518
20.00-
0.6000
0.6000
40.00
T20
3
1 518
20.00-
0.6000
0.6000
40.00
T20
4
1 518
20.00-
0.6000
0.6000
40.00
T20
5
1 518
20.00 -
0.6000
0.6000
40.00
T20
6
3/8
20.00-
0.6000
0.6000
40.00
T20
7
318
20.00-
0.6000
0.6000
40.00
T20
8
718
20.00-
0.6000
0.6000
40.00
T20
9
LDF2-50A (318 FOAM)
20.00-
0.6000
0.6000
40.00
T20
10
1 5/8
20.00-
0.6000
0.6000
40.00
T20
11
1 518
20.00 -
0.6000
0.6000
40.00
_ T20
_ 12
:39mm Hybrid (1.535in)
20.00-
0.6000
0.6000
40.00
1 T20
13
`• 1 5/8
20.00-
0.6000
0.6000
40.00
T20
14
7/8
20.00-
0.6000
0.6000
40.00
T20
15
LDFl-50A(1/4 FOAM)
20.00-
0.6000
0.6000
40.00
T20
16
1 518
20.00-
0.6000
0.6000
40.00
T20
17
518
20.00-
0.6000
0.6000
40.00
T20
18
518
20.00-
0.6000
0.6000
40.00
T20
19
LDFl-50A(114 FOAM)
20.00-
0.6000
0.6000
40.00
T20
20
LDF4-50A (1/2 FOAM)
20.00-
0.6000
0.6000
40.00
T20
21
7/8
20.00-
0.6000
0.6000
40.00
T20
22
7/8
20.00-
0.6000
0.6000
Page 39
July 17, 2015
Rigorous Structural Analysis Report - Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
KU
Ice
40.00
T20
23
7/8
20.00 -
0.6000
0.6000
40.00
T20
24
7/8
20.00 -
0.6000
0.6000
40.00
T20
25
LDF4-50A (1/2 FOAM)
20.00 -
0.6000
0.6000
40.00
T20
26
1 518
20.00 -
0.6000
0.6000
40.00
T20
27
1 5/8
20.00 -
0.6000
0.6000
40.00
T20
28
1 518
20.00 -
0.6000
0.6000
40.00
T20
29
1 5/8
20.00 -
0.6000
0.6000
40.00
T20
30
1 518
20.00 -
0.6000
0.6000
40.00
T20
31
1 1/4
20.00 -
0.6000
0.6000
40.00
T20
32
1 518
20.00 -
0.6000
0.6000
40.00
T20
33
1 518
20.00 -
0.6000
0.6000
40.00
T20
34
1 518
20.00 -
0.6000
0.6000
40.00
T20
35
1 518
20.00 -
0.6000
0.6000
40.00
T21
1
1 518
4.67 - 20.00
0.6000
0.6000
T21
2
1 518
4.67 - 20.00
0.6000
0.6000
T21
3
1 518
4.67 - 20.00
0.6000
0.6000
T21
4
1 518
4.67 - 20.00
0.6000
0.6000
T21
5
1 518
4.67 - 20.00
0.6000
0.6000
T21
6
318
4.67 - 20.00
0.6000
0.6000
T21
7
318
4.67 - 20.00
0.6000
0.6000
T21
8
7/8
4.67 - 20.00
0.6000
0.6000
T21
9
LDF2-50A (3/8 FOAM)
4.67 - 20.00
0.6000
0.6000
T21
10
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
11
1 518
4.67 - 20.00
0.6000
0.6000
T21
12
39mm HybHd(1.5351n)
4.67-20.00
0.6000
0.6000
T21
13
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
14
7/8
4.67 - 20.00
0.6000
0.6000
T21
15
LDFl-50A(1/4 FOAM)
4.67-20.00
0.6000
0.6000
T21
16
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
17
5/8
4.67 - 20.00
0.6000
0.6000
T21
18
5/8
4.67 - 20.00
0.6000
0.6000
T21
19
LDFl-50A(1/4 FOAM)
4.67-20.00
0.6000
0.6000
T21
20
LDF4-50A(1/2 FOAM)
4.67-20.00
0.6000
0.6000
T21
21
718
4.67 - 20.00
0.6000
0.6000
T21
22
7/8
4.67 - 20.00
0.6000
0.6000
T21
23
7/8
4.67 - 20.00
0.6000
0.6000
T21
24
7/8
4.67 - 20.00
0.6000
0.6000
T21
25
LDF4-50A(112 FOAM)
4.67-20.00
0.6000
0.6000
T21
26
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
27
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
28
1 518
4.67 - 20.00
0.6000
0.6000
T21
29
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
30
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
31
1 1/4
4.67 - 20.001
0.60001
0.6000
Page 40
July 17, 2015
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower
CALTROP Corporation
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment
Elev.
K.
No Ice
Ka
Ice
T21
32
1 518
4.67 - 20.00
0.6000
0.6000
T21
33
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
34
1 5/8
4.67 - 20.00
0.6000
0.6000
T21
35
1 5/8
4.67 - 20.00
0.6000
0.6000
T22
1
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
2
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
3
1 518
0.00 - 4.67
0.6000
0.6000
T22
4
1 518
0.00 - 4.67
0.6000
0.6000
T22
5
1 518
0.00 - 4.67
0.6000
0.6000
T22
6
3/8
0.00 - 4.67
0.6000
0.6000
T22
7
318
0.00 - 4.67
0.6000
0.6000
T22
8
7/8
0.00 - 4.67
0.6000
0.6000
T22
9
LDF2-50A (3/8 FOAM)
0.00 - 4.67
0.6000
0.6000
T22
10
1 518
0.00 - 4.67
0.6000
0.6000
T22
11
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
12
39mm Hybrid(1.535in)
0.00-4.67
0.6000
0.6000
T22
13
1 518
0.00 - 4.67
0.6000
0.6000
T22
14
7/8
0.00 - 4.67
0.6000
0.6000
T22
15
LDF1-50A(114 FOAM)
0.00-4.67
0.6000
0.6000
T22
16
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
17
5/8
0.00 - 4.67
0.6000
0.6000
T22
18
5/8
0.00 - 4.67
0.6000
0.6000
T22
19
LDFl-50A(1/4 FOAM)
0.00-4.67
0.6000
0.6000
T22
20
LDF4-50A (1/2 FOAM)
0.00 - 4.67
0.6000
0.6000
T22
21
7/8
0.00 - 4.67
` 0.6000
0.6000
T22
22
718
0.00 - 4.67
0.6000
0.6000
T22
23
7/8
0.00 - 4.67
0.6000
0.6000
T22
24
7/8
0.00 - 4.67
0.6000
0.6000
T22
25
LDF4-50A (1/2 FOAM)
0.00 - 4.67
0,6000
0.6000
T22
26
1 518
0.00 - 4.67
0.6000
0.6000
T22
27
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
28
1 518
0.00 - 4.67
0.6000
0.6000
T22
29
1 518
0.00 - 4.67
0.6000
0.6000
T22
30
1 5/8
0.00 - 4.67
0.6000
0.6000
T22
31
_ 1 1/4
0.00 - 4.67
0.6000
0.6000
T22
32
1 518
0.00 - 4.67
0.6000
0.6000
T22
33
" 1 518
0.00 - 4.67
0.6000
0.6000
T22
34
1 5/8
0.00 - 4.67
0.6000
0.6000
' T22
35
1 5/8
0.00 - 4.67
0.6000
0.6000
Discrete` Tower Loads -
July 17, 2015
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
weight
or
Type
Horz
Adjustmen
Front
Side
Leg
Lateral
t
Vert
ft
ft
Rr
/t2
K
ft
°
ft
Flash Beacon Lighting
C
None
0.0000
480.00 No Ice
2.70
2.70
0.05
DB224-E
C
From Leg
3.00
0.0000
442.00 No Ice
4.50
4.50
0.04
0.00
Page 41
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower July 17, 2015
CALTROP Corporation
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustmen
Front
Side
Leg
Lateral
t
Vert
it
ft
ftz
ftz
K
It
it
0.00
Standoff 2'
C
None
0.0000
442.00
No Ice
0.30
0.30
0.01
Dipole 10'
A
From Leg
1.00
0.0000
441-.50
No Ice
11.11
5.00
0.03
0.00
0.00
Standoff 1'
A
None
0.0000
441.50
No Ice
0.13
0.13
0.01
Dipole 10'
C
From Leg
1.00
0.0000
422.50
No Ice
11.11
5.00
0.03
0.00
0.00
Standoff 1'
C
None
0.0000
422.50
No Ice
0.13
0.13
0.01
Omni 10' by 3"
B
From Leg
6.00
0.0000
410.00
No Ice
2.00
2.00
0.04
0.00
0.00
Standoff 5'
B
None
0.0000
410.00
No Ice
0.79
0.79
0.02
Dipole 10'
A
From Leg
1.00
0.0000
406.00
No Ice
11.11
5.00
0.03
0.00
0.00
Standoff 1'
A
None
0.0000
406.00
No Ice
0.13
0.13
0.01
8-Bay Dipole
B
From Leg
2.00
0.0000
373.00
No Ice
5.40
5.40
0.08
0.00
0.00
Standoff 2'
B
None
0.0000
373.00
No Ice
0.30
0.30
0.01
4-Bay Dipole
C
From Leg
2.00
0.0000
370.50
No Ice
4.00
4.00
0.05
0.00
0.00
Standoff 2'
C
None
0.0000
370.50
No Ice
0.30
0.30
0.01
Omni 4' by 1.5" w/Pipe
C
From Leg
5.00
0.0000
356.00
No Ice
0.60
0.60
0.02
Mount
0.00
Standoff 5'
C
None
0.00
0.0000
356.00
No Ice
L
9
2
Omni 12' by 3"
A
From Leg
1.00
0.0000
350.00
No IceHOF60
3
0.00
0.00
Standoff V
A
None
0.0000
350.00
No Ice
0.13
0.13
0.01
Omni 12' by 4"
A
From Leg
1.00
0.0000
337.00
No Ice
4.80
4.80
0.08
0.00
0.00
Standoff 1'
A
None
0.0000
337.00
No Ice
0.13
0.13
0.01
R55247
B
From Leg
2.00
0.0000
317.00
No Ice
16.88
16.88
0.20
0.00
0.00
Standoff 2'
B
None
0.0000
317.00
No Ice
0.30
0.30
0.01
Flash Beacon Lighting
B
None
0.0000
242.00
No Ice
2.70
2.70
0.06
(2) 6' Yagi
B
None
0.0000
287.50
No Ice
1.50
1.50
0.03
(2) AXP 19-60-2
A
From Face
3.00
0.0000
226.00
No Ice
4.86
3.40
0.02
(Verizon)
0.00
0.00
(2) AXP 19-60-2
B
From Face
3.00
0.0000
226.00
No Ice
4.86
3.40
0.02
(Verizon)
0.00
0.00
(2) AXP 19-60-2
C
From Face
3.00
0.0000
226.00
No Ice
4.86
3.40
0.02
(Verizon)
0.00
0.00
X7-665
A
From Face
3.00
0.0000
226.00
No Ice
8.75
6.71
0.06
Page 42
Rigorous Structural Analysis Report- Verizon: 61713 - Spain Tower July 17. 2015
CALTROP Corporation
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustmen
Front
Side
Leg
Lateral
t
Vert
It
it
fe
ta
K
It
It
(Verizon)
0.00
0.00
X7-665
B
From Face
3.00
0.0000
226.00
No Ice
8.75
6.71
0.06
(Verizon)
0.00
0.00
X7-665
C
From Face
3.00
0.0000
226.00
No Ice
8.75
6.71
0.06
(Verizon)
0.00
0.00
Rohn 6'x10' Boom Gate (3)
A
From Leg
0.00
0.0000
226.00
No Ice
47.40
47.40
1.62
(Verizon)
0.00
0.00
APXV18-206517S-C-A20
A
From Face
5.00
0.0000
206.50
Noire
5.64
4.94
0.06
w/ Pipe
0.00
(T-Mobile)
0.00
APXV18-206517S-C-A20
B
From Face
5.00
0.0000
206.50
No Ice
5.64
4.94
0.06
w/ Pipe
0.00
(T-Mobile)
0.00
APXV18-206517S-C-A20
C
From Face
5.00
0.0000
206.50
No Ica
5.64
4.94
0.06
w/ Pipe
0.00
(T-Mobile)
0.00
(2)APXI7DWV-17DWV-S-
A
From Face
5.00
0.0000
206.50
No Ice
9.68
5.00
0.05
E-A20
0.00
(T-Mobile)
0.00
(2)APXI7DWV-17DWV-S-
B
From Face
5.00
0.0000
206.50
No Ice
9.68
5.00
0.05
E-A20
0.00
(T-Mobile)
0.00
(2)APXI7DWV-17DWV-S-
C
From Face
5.00
0.0000
206.50
Noire
9.68
6.00
0.05
E-A20
0.00
(T-Mobile)
0.00
FRIG (RF Module) •`
A,
From Face
2.00
0.0000
206.50
No Ice
2.98
1.02
0.05
,,(T-Mobile)
0.00
0.00
FRIG (RF Module)
B
From Face
2.00
0.0000
206.50
No Ice
2.98
1.02
0.05
(T-Mobile)
0.00
0.00
FRIG (RF Module)
C
From Face
2.00
0.0000
206.50
No Ice
2.98
1.02
0.05
(T-Mobile)
0.00
0.00
FXxx (RF Module)
A
From Face
2.00
0.0000
206.50
No Ice
4.17
1.12
0.06
(T-Mobile)
0.00
0.00
FXxx (RF Module)
B
From Face
2.00
0.0000
206.50
No Ice
4.17
1.12
0.06
(T-Mobile)
0.00
0.00
FXxx (RF Module)
C
From Face
2.00
0.0000
206.50
No Ice
4.17
1.12
0.06
(T-Mobile)
0.00
0.00
(2) ATMAP1412D-tA20
A
From Face
5.00
0.0000
206.50
Noire
1.17
0.47
0.01
(TMA)
0.00
(T-Mobile)
0.00
(2) ATMAP1412D-1A20
B
From Face
5.00
0.0000
206.50
No Ice
1.17
0.47
0.01
(TMA)
0.00
(T-Mobile)
0.00
(2) ATMAP1412D-1A20
C
From Face
5.00
0.0000
206.50
No Ice
1.17
0.47
0.01
Page 43
Rigorous Structural Analysis Report-
VerCon: 62713-Spain Tower
July 17, 2015
CALTROP Corporation
Description Face
Offset Offsets: Azimuth Placement
CAAA
CAAA Weight
or
Type Horz Adjustmen
Front
Side
Leg
Lateral t
Vert
ft ft
fit
ft' K
ft o
ft
Pis'
ryrypp
go N�
o
(TMA)
0.00
(T-Mobile)
0.00
ASU9338TYP0l
C
From Face
2.00
0.0000
206.50
No Ice
2.96
1.II8
2
(RNSNDC-7771-PF-48)
0.00
(COVP High)
0.00
(T-Mobile)
Standoff Sector Mount 13'
A
From Leg
0.00
0.0000
206.50
No Ice
12.65
12.65
0.25
(T-Mobile)
0.00
0.00
Standoff Sector Mount 13'
B
From Leg
0.00
0.0000
206.50
No Ice
12.65
12.65
0.25
(T-Mobile)
0.00
0.00
Standoff Sector Mount 13'
C
From Leg
0.00
0.0000
206.50
No Ice
12.65
12.66
0.25
(T-Mobile)
0.00
0.00
(2) 800-10122 (AP14/17-
A
From Face
5.00
0.0000
195.00
No Ice
7.61
4.92
0.06
880/1940/088D/ADT/XXP)
0.00
(AT&T)
0.00
(2) 800-10122 (AP14/17-
B
From Face
5.00
0.0000
195.00
No Ice
7.61
4.92
0.06
880/1940/088D/ADT/XXP)
0.00
(AT&T)
0.00
(2) 800-10122 (AP14/17-
C
From Face
5.00
0.0000
195.00
No Ice
7.61
4.92
0.06
880/19401088D/ADT/XXP)
0.00
(AT&T)
0.00
800-10764
A
From Face
5.00
0.0000
195.00
No Ice
5.99
3.17
0.05
(AT&T)
0.00
0.00
800-10764
B
From Face
5.00
0.0000
195.00
No Ice
5.99
3.17
0.05
(AT&T)
0.00
0.00
800-10764
C
From Face
5.00
0.0000
195.00
No Ice
5.99
3.17
0.05
(AT&T)
0.00
0.00
(2) ATM19801712-0 (TMA)
A
From Face
5.00
0.0000
195.00
No Ice
1.12
0.58
0.02
(AT&T)
0.00
0.00
(2) ATM19801712-0 (TMA)
B
From Face
5.00
0.0000
195.00
No Ice
1.12
0.58
0.02
(AT&T)
0.00
0.00
(2) ATM19801712-0 (TMA)
C
From Face
5.00
0.0000
195.00
No Ice
1.12
0.58
0.02
(AT&T)
0.00
0.00
(2) FDGW5504/3C-3
A
From Face
5.00
0.0000
195.00
No Ice
0.39
0.08
0.00
(diplexer)
0.00
(AT&T)
0.00
(2) FDGW5504/3C-3
B
From Face
5.00
0.0000
195.00
No Ice
0.39
0.08
0.00
(diplexer)
0.00
(AT&T)
0.00
(2) FDGW5504/3C-3
C
From Face
5.00
0.0000
195.00
No Ice
0.39
0.08
0.00
(diplexer)
0.00
(AT&T)
0.00
(4)860 10025
A
From Face
5.00
0.0000
195.00
No Ice
0.16
0.14
0.00
(AT&T)
0.00
0.00
Page 44
Rigorous Structurat Analysis Report - Perizon: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
t
Vert
it
R
fie
fie
K
R
ft
(4) 860 10025
_ B
From Face
5.00
0.0000
195.00
No Ice
0.16
0.14
0.00
(AT&T),
0.00
0.00
(4) 860 10025
C
From Face
6.00
0.0000
195.00
No Ice
0.16
0.14
0.00
(AT&T)
0.00
0.00
RRUS-11 (2, stacked)
A
From Face
2.00
0.0000
195.00
No Ice
2.94
3.04
0.11
(AT&T)
0.00
0.00
RRUS-11 (2, stacked)
B
From Face
2.00
0.0000
195.00
No Ice
2.94
3.04
0.11
(AT&T)
0.00
0.00
RRUS-11 (2, stacked)
C
From Face
2.00
0.0000
195.00
No Ice
2.94
3.04
0.11
(AT&T)
0.00
0.00
Raycap DC6-48-60-18-8F
C
From Face
2.00
0.0000
195.00
No Ice
1.47
1.47
0.02
(AT&T)
0.00
0.00
Rohn 6'x15' Boom Gate (3)
A
None
0.0000
195.00
No Ice
53.20
53.20
1.79
(AT&T)
(2) AP18-1900/090D
A
From Leg
4.00
0.0000
172.50
No Ice
5.30
3.69
0.04
w/Mount Pipe
0.00
(Sprint)
0.00
(2) AP18-1900/090D
B
From Leg
4.00
0.0000
172.50
No Ice
5.30
3.69
0.04
w/Mount Pipe
0.00
(Sprint)
0.00
(2) AP18-1900/090D
C
From Leg
4.00
0.0000
172.50
No Ice
5.30
3.69
0.04
w/Mount Pipe
0.00
(Sprint)
0.00
APXV9ERR18-C
A
From Leg
4.00
0.0000
172.50
No Ice
8.26
5.28
0.06
(Sprint)
0.00
0.00
APXV9ERR18-C
B
From Leg
4.00
0.0000
172.50
No Ice
8.26
5.28
0.06
(Sprint)
0.00
0.00
APXV9ERR18-C
C
From Leg
4.00
0.0000
172.50
No Ice
8.26
5.28
0.06
(Sprint)
0.00
0.00
(3) ACU-A20-N (RET)
A
From Leg
4.00
0.0000
172.50
No Ice
0.08
0.14
0.00
(Sprint)
0.00
0.00
(3) ACU-A20-N (RET)
B
From Leg
4.00
0.0000
172.50
No Ice
0.08
0.14
0.00
(Sprint)
0.00
0.00
(3) ACU-A20-N (RET)
C
From Leg
4.00
0.0000
172.50
No Ice
0.08
0.14
0.00
(Sprint)
0.00
0.00
(2) RRUS-11 (2, stacked)
A
From Leg
4.00
0.0000
172.50
No Ice
2.94
3.04
0.11
(Sprint)
0.00
0.00
(2) RRUS-11 (2, stacked)
B
From Leg
4.00
0.0000
172.60
No Ice
2.94
3.04
0.11
(Sprint)
0.00
0.00
(2) RRUS-11 (2, stacked)
C
From Leg
4.00
0.0000
172.50
No Ice
2.94
3.04
0.11
Page 45
Rigorous Structural Analysis Report- Verizan: 62713-Spain Tower July 17. 2015
CALTROP Corporation
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustmen
Front
Side
Leg
Lateral
t
Vert
it
it
ftr
ft2
K
ft
ft
(Sprint)
0.00
0.00
RRUS-A2 Module (side)
A
From Leg
4.00
0.0000
172.50
No Ice
0.50
1.87
0.02
(Sprint)
0.00
0.00
RRUS-A2 Module (side)
B
From Leg
4.00
0.0000
172.50
No Ice
0.50
1.87
0.02
(Sprint)
0.00
0.00
RRUS-A2 Module (side)
C
From Leg
4.00
0.0000
172.50
No Ice
0.50
1.87
0.02
(Sprint)
0.00
0.00
IBC1900HG-1 (Combiner)
A
From Leg
4.00
0.0000
172.50
No Ice
1.38
0.41
0.02
(Sprint)
0.00
0.00
IBC1900HG-1 (Combiner)
B
From Leg
4.00
0.0000
172.50
No Ice
1.38
0.41
0.02
(Sprint)
0.00
0.00
IBC1900HG-1 (Combiner)
C
From Leg
4.00
0.0000
172.50
No Ice
1.38
0.41
0.02
(Sprint)
0.00
0.00
800 SMR Filter
A
From Leg
4.00
0.0000
172.50
No Ice
0.30
0.84
0.02
(Sprint)
0.00
0.00
800 SMR Filter
B
From Leg
4.00
0.0000
172.60
No Ice
0.30
0.84
0.02
(Sprint)
0.00
0.00
800 SMR Filter
C
From Leg
4.00
0.0000
172.50
No Ice
0.30
0.84
0.02
(Sprint)
0.00
0.00
Valmont 13' Standoff A None
Frame (3)
(Sprint)
3' Yagi C From Leg
Standoff 2' C From Leg
b)(rAIrNi YP�.Tr1•�R7['2t�-'S�4r)�S�4riNN:
2.00 0.0000 116.50 No Ice 0.60 0.60 0.02
0.00
0.00
0.00 0.0000 116.50 No Ice 0.30 0.30 0.01
0.00
Dishes
Description Face
Dish
Offset
Offsets:
Azimuth 3 dB
Elevation Outside
Aperture
Weight
or
Type
Type
Horz
Adjustment Beam
Diameter
Area
Leg
Lateral
Width
Vert
ft
it ft
It,
K
GP6F-21A B
Grid
From
0.00
0.0000
104.50 6.00
No Ice 28.30
0.20
Leg
0.00
0.00
Page 46
Rigorous Structural Analysis Report- Verizon: 61713-Spain Tower
CALTROP Corporation
July 17. 2015
Description Face
Dish
Offset
Offsets:
Azimuth 3 dB
Elevation Outside
Aperture
Weight
or
Type
Type
Horz
Adjustment Beam
Diameter
Area
Leg
Lateral
Width
Vert
ft
°
ft ft
ft2
K
GP6F-21A B
Grid
From
0.00
0.0000
97.50 6.00 No Ice
28.30
0.20
Leg
0.00
Force Totals Does not include forces on guys)
Load
Case
Vertical
Forces
K
Sum of
Forces
X
K
Sum of
Forces
Z
K
Sum of
Torques
kip-ft
Leg Weight
20.10
Bracing Weight
10.75
Total Member Self -Weight
30.86
Guy Weight
11.99
_
Total Weight
68.59
Wind 0 deg - No Ice
-0.03
-85.20
-7.09
Wind 30 deg- No Ice
44.59
-77.26
-9.57
Wind 60 deg - No Ice
76.87
44.42
-7.37
Wind 90 deg - No Ice
87.77
0.03
-3.53
Wind 120 deg - No Ice
74.36
43.07
0.46
Wind 160 deg - No Ice
43.63
75.75
4.52
Wind 180 deg - No Ice
0.08
84.63
7.14
Wind 210 deg - No Ice
-44.41
77.36
9.57
Wind 240 deg - No Ice
-77.33
44.75
7.33
Wind 270 deg - No Ice
-87.77
0.04
3.39
Wind 300 deg - No Ice
-73.74
-42.71
-0.47
Wind 330 deg - No Ice
43.58
-75.78
-4.38
Total Weight
68.59
-0.01
-20.61
-1.72
Wind 0 deg - Service
Wind 30 deg - Service
10.78
-18.69
-2.31
Wind 60 deg - Service
18.59
-10.74
-1.78
Wind 90 deg - Service
21.23
0.01
-0.85
Wind 120 deg - Service
17.99
10.42
0.11
Wind 150 deg - Service
10.55
18.32
1.09
Wind 180 deg*- Service
0.02
20.47
1.73
Wind 210 deg - Service
-10.74
18.71
2.31
Wind 240 deg - Service
-18.70
10.82
1.77
Wintl270 deg - Service•
-21.23
0.01
0.82
Wind 300 deg -'Service
-17.84
-10.33
-0.11
Wind 330 deg -Service
-10.54
-18.33
-1.06
Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg - No Ice+1.0 Guy
3 1.2 Dead+1.6 Wind 30 deg - No Ice+1.0 Guy
Page 47
Rigoroar Structural Analysis Report- Verizon: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Comb. Description
No.
4 1.2 Dead+1.6 Wind 60 deg - No Ice+1.0 Guy
5 1.2 Dead+1.6 Wind 90 deg - No Ice+1.0 Guy
6 1.2 Dead+1.6 Wind 120 deg - No Ice+1.0 Guy
7 1.2 Dead+1.6 Wind 150 deg -No Ice+1.0 Guy
8 1.2 Dead+1.6 Wind 180 deg - No Ice+1.0 Guy
9 1.2 Dead+1.6 Wind 210 deg -No Ice+1.0 Guy
10 1.2 Dead+1.6 Wind 240 deg -No Ice+1.0 Guy
11 1.2 Dead+1.6 Wind 270 deg -No Ice+1.0 Guy
12 1.2 Dead+1.6 Wind 300 deg -No Ice+1.0 Guy
13 1.2 Dead+1.6 Wind 330 deg - No Ice+1.0 Guy
14 Dead+Wind 0deg -Service+Guy
15 Dead+Wind 30 deg - Service+Guy
16 Dead+Wind 60 deg - Service+Guy
17 Dead+Wind 90 deg - Service+Guy
18 Dead+Wind 120 deg - Service+Guy
19 Dead+Wind 150 deg - Service+Guy
20 Dead+Wind 180 deg - Service+Guy
21 Dead+Wind 210 deg - Service+Guy
22 Dead+Wind 240 deg -Service+Guy (lC()PY
23 Dead+Wind 270 deg - Service+Guy
24 Dead+Wind 300 deg - Service+Guy
25 Dead+Wind 330 deg - Service+Guy
Maximum Reactions.
Location
Condition
Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Mast
Max. Vert
2
379.46
-0.07
3.28
Max. H.
12
332.24
5.30
3.09
Max. H.
3
362.57
-3.42
3.31
Max. M.
1
0.00
-0.05
-0.02
Max. M.
1
0.00
-0.05
-0.02
Max. Torsion
3
4.82
-3.42
3.31
Min. Vert
1
182.00
-0.05
-0.02
Min. H.
4
332.30
-5.44
3.15
Min. H.
8
332.60
-0.02
-6.25
Min. M.
1
0.00
-0.05
-0.02
Min. M.
1
0.00
-0.05
-0.02
Min. Torsion
8
-6.09
-0.02
-6.25
Guy C @ 250 ft
Max. Vert
10
-18.24
-8.02
4.63
Elev 0 It
Azimuth 240 deg
Max. H.
10
-18.24
-8.02
4.63
Max. H.
3
-163.62
-169.43
102.62
Min. Vert
4
-164.22
-168.25
97.17
Min. Hx
5
-163.19
-174.04
95.73
Min. H.
10
-18.24
-8.02
4.63
Guy B @ 250 ft
Max. Vert
6
-18.33
8.06
4.65
Elev 0 ft
Azimuth 120 deg
Max. H.
11
-163.20
174.11
95.77
Max. H.
13
-163.60
170.20
103.03
Min. Vert
12
-164.09
168.59
97.34
Min. H.
6
-18.33
8.06
4.65
Min. H.
6
-18.33
8.06
4.65
Page 48
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17, 2015
CALTROP Corporation
Location
Condition
Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Guy A @ 250 ft
Max. Vert
2
-18.13
-0.00
-9.19
Elev 0 ft
Azimuth 0 deg
Max. H.
11
-94.30
8.37
-107.43
Max. H.
2
-18.13
-0.00
-9.19
Min. Vert
8
-164.66
0.02
-194.61
Min. H.
5
-93.94
-8.37
-107.44
Min. Hz
7
-163.70
-4.11
-198.94
Tower Mast Reaction Summary.
Torque
Load
Vertical
Shea,
Shea,
Overturning
Overturning
Combination
Moment, M,
Moment, M.
• K
K
K
kip -It
kip-ft
kip-ft
Dead Only
• • 182.00
0.05
0.02
0.00
0.00
-0.00
1.2 Dead+1.6 Wind 0 deg -
., _.� 379.46
0.07
-3.28
0.00
0.00
-4.34
No Ice+1•.0 Guy ' '
1.2 Dead+1.6 Wind 30 deg -
362.57
3.42
-3.31
0.00
0.00
-4.82
No Ice+1.0 Guy
1.2 Dead+1.6 Wind 60 deg -
332.30
5.44
-3.15
0.00
0.00
-4.20
No Ice+1.0 Guy
1.2 Dead+1.6 Wind 90 deg -
361.94
4.55
-1.28
0.00
0.00
-1.79
No Ice+1.0 Guy
1.2 Dead+1.6 Wind 120 deg
378.56
2.86
1.63
0.00
0.00
1.10
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 150 deg
362.32
1.17
4.54
0.00
0.00
3.84
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 180 deg
332.60
0.02
6.25
0.00
0.00
5.09
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 210 deg
362.32
-1.14
4.59
0.00
0.00
4.81
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 240 deg
378.77
-2.80
1.68
0.00
0.00
3.54
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 270 deg
362.21
-4.41
-1.25
0.00
0.00
1.75
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 300 deg
332.24
-5.30
-3.09
0.00
0.00
-1.25
- No Ice+1.0 Guy
1.2 Dead+1.6 Wind 330 deg
362.83
-3.27
-3.21
0.00
0.00
-3.79
- No Ice+1.0 Guy
Dead+Wind 0 deg -
186.60
0.06
-1.27
0.00
0.00
-0.98
Service+Guy
Dead+Wind 30 deg -
186.44
0.69
-1.11
0.00
0.00
-1.06
Service+Guy
Dead+Wind 60 deg -
186.38
1.15
-0.62
0.00
0.00
-0.84
Service+Guy
Dead+Wind 90 deg -
186.48
1.35
0.02
0.00
0.00
-0.43
Service+Guy
Dead+Wind 120 deg -
186.65
1.16
0.66
0.00
0.00
0.22
Service+Guy
Dead+Wind 150 deg -
186.48
0.71
1.13
0.00
0.00
0.83
Service+Guy
Dead+Wind 180 deg -
186.39
0.05
1.29
0.00
0.00
0.99
Service+Guy
Dead+Wind 210 deg -
186.46
-0.60
1.13
0.00
0.00
1.06
Page 49
Rigorous Structural Analysis Report- Vernon: 62713- Spain Tower July 17, 2015
CAL TROP Corporation
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment, M, Moment, M.
Dead+Wind 240 deg -
186.63
-1.06
0.66
0.00
0.00
0.83
Service+Guy
Dead+Wind 270 deg -
186.48
-1.24
0.03
0.00
0.00
0.41
Service+Guy
Dead+Wind 300 deg -
186.40
-1.04
-0.62
0.00
0.00
-0.22
Service+Guy
Dead+Wind 330 deg -
186.46
-0.58
-1.11
0.00
0.00
-0.82
Service+Guy
Solution Summary
Sum of Applied Forces
Sum of Reactions
Load
PX
PY
PZ
PX
PY
PZ
% Error
Comb.
K
K
K
K
K
K
1
0.00
-68.58
0.00
0.00
68.58
0.00
0.002%
2
-0.04
-81.26
-175.47
0.04
81.26
175.46
0.005%
3
87.40
-79.90
-151.44
-87.41
79.90
151.43
0.005%
4
150.86
-78.55
-87.16
-150.86
78.55
87.15
0.004%
5
176.12
-79.90
0.04
-175.12
79.90
-0.04
0.005%
6
151.99
-81.26
87.97
-151.98
81.26
-87.96
0.006%
7
87.60
-79.90
152.01
-87.59
79.90
-152.01
0.005%
8
0.13
-78.55
174.55
-0.14
78.55
-174.56
0.004%
9
-87.13
-79.90
151.60
87.12
79.90
-151.60
0.005%
10
-151.61
-81.26
87.70
151.60
81.26
-87.69
0.006%
11
-175.12
-79.90
0.06
175.12
79.90
-0.05
0.005%
12
-151.00
-78.55
-87.40
151.01
78.55
87.39
0.004%
13
-87.51
-79.90
-152.06
87.51
79.90
152.05
0.006%
14
-0.01
-68.79
-26.53
0.01
68.79
26.53
0.002%
15
13.21
-68.58
-22.89
-13.21
68.58
22.89
0.001%
16
22.81
-68.38
-13.18
-22.80
68.38
13.18
0.001%
17
26.47
-68.58
0.01
-26.47
68.58
-0.01 0.001%
18
22.98
-68.79
13.30
-22.98
68.79
-13.30 0.002%
19
13.24
-68.58
22.98
-13.24
68.58
-22.98 0.001%
20
0.02
-68.38
26.39
-0.02
68.38
-26.39 0.001%
21
-13.17
-68.58
22.92
13.17
68.58
-22.92 0.001%
22
-22.92
-68.79
13.26
22.92
68.79
-13.26 0.002%
23
-26.47
-68.58
0.01
26.47
6688.58
-0.01 0.001%
25
-13.23
-68.58
-22.99
13.23
145
r A 0 ",
Non -Linear Convergence Results
Load
Converged?
Number
Displacement
Force
Combination
of Cycles
Tolerance
Tolerance
1
Yes
10
0.00000001
0.00003912
2
Yes
66
0.00009084
0.00005643
3
Yes
65
0.00009122
0.00004917
4
Yes
38
0.00009720
0.00004111
5
Yes
64
0.00009383
0.00004937
6
Yes
65
0.00009568
0.00005837
7
Yes
64
0.00009694
0.00005121
Page 50
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17, 2015
CALTROP Corporation
8
Yes
29
0.00009081
0.00003725
9
Yes
64
0.00009975
0.00005334
10
Yes
65
0.00009770
0.00006014
11
Yes
64
0.00009439
0.00005007
12
Yes
33
0.00009268
0.00003994
13
Yes
64
0.00009853
0.00005290
14
Yes
18
0.00000001
0.00001410
15
Yes
27
0.00000001
0.00001631
16
Yes
28
0.00000001
0.00001702
17
Yes
27
0.00000001
0.00001638
18
Yes
18
0.00000001
0.00001656
19
Yes
27
0.00000001
0.00001739
20
Yes
28
0.00000001
0.00001763
21
Yes
27
0.00000001
0.00001733
22
Yes
18
0.00000001
0.00001650
23
Yes
.26
0.00000001
0.00001954
24
Yes
28
0.00000001
0.00001667
25
Yes
26
0.00000001
0.00001956
Bolt Design
Data
Section
Elevation
Component
Bolt
Bolt Size
Number
Maximum
Allowable
Ratio
Allowable
Criteria
No.
Type
Grade
Of
Load per
Load
Load
Ratio
ft
in
Bolts
Bolt
K
Allowable
K
L1
480
Latticed Pole
A325X
0.6250
5
0.00
20.71
0.000 ✓
1
Bolt Tension
Leg
L2
460
Latticed Pole
A325X
0.6250
5
1.82
20.71
0.088 ✓
1
Bolt Tension
Leg
1-3
440
Latticed Pole
A325N
0.6250
5
3.45
20.71
0.166 ✓
1
Bolt Tension
Leg
T1
400
Leg
A325X
0.6250
5
4.04
20.71
0.195 ✓
1
Bolt Tension
T2
380
Leg
A325X
0.6250
5
4.37
20.71
0.211 ✓
1
Bolt Tension
T3
360
Leg
A325X
0.6250
5
4.70
20.71
0.227 ✓
1
Bolt Tension
T4
340
Leg
A325X
0.6250
5
5.85
20.71
0.282 ✓
1
Bolt Tension
Top Guy Pull-
A325N
1.0000
1
7.22
31.81
0.227 ✓
1
Bolt Shear
Off@339.667
T5
320
Leg
A325X
0.6250
5
6.74
20.71
0277 ✓
1
Bolt Tension
T6
_ 300
Leg
A325X
0.6250
5
6.29
20.71
0.304 ✓
1
Bolt Tension
T7.
,- , 280
Leg
A325X
0.6250
5
7.53
20.71
0.364 ✓
1
Bolt Tension
T8-
.260
Leg _ _
A325X
0.6250
5
5.57
20.71
0.269 ✓
1
Bolt Tension
T9
240
Leg
A325X
0.6250
5
4.67
20.71
0.226 ✓
1
Bolt Tension
T10
220
Leg
A325X
0.6250
5
4.83
20.71
0.233 ✓
1
Bolt Tension
Ttt
200
Leg
A325X
0.6250
5
7.29
20.71
0.352 ✓
1
Bolt Tension
T12
192.5
Leg
A325X
0.6250
5
6.62
20.71
0.320 ✓
1
Bolt Tension
T13
180
Leg
A325X
0.6250
5
6.14
20.71
0.297 //
1
Bolt Tension
T14
160
Leg
A325X
0.6250
5
7.72
20.71
0.373 ✓
1
Bolt Tension
T15
140
Leg
A325X
0.6250
5
7.40
20.71
0.357 ✓
1
Bolt Tension
T16
120
Leg
A325X
0.6250
5
10.00
20.71
0.483 ✓
1
Bolt Tension
T17
100
Leg
A325X
0.6250
5
11.70
20.71
0.565 ✓
1
Bolt Tension
Page 51
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower July 17, 2015
CALTROP Corporation
Section
Elevation
Component
Bolt
Bolt Size
Number
Maximum
Allowable
Ratio
Allowable
Criteria
No.
Type
Grade
Of
Loadper
Load
Load
Ratio
ft
in
Bolts
Bolt
K
Allowable
K
T18
80
Leg
A325X
0.6250
5
9.51
20.71
0.459 ✓
1
Bolt Tension
T19
60
Leg
A325X
0.6250
5
10.08
20.71
0.487 ✓
1
Bolt Tension
T20
40
Leg
A325X
0.6250
5
12.36
20.71
0597 ✓
1
Bolt Tension
T21
20
Leg
A325X
0.6250
5
11.61
20.71
0.560 ✓
1
Bolt Tension
T22
4.66667
Leg
A325X
0.6250
5
8.70
9.97
1
Bolt Tension
0.872 :/
Guy
Design Data
9 N...d
a j
S&j
NEVIGMV
:coon
Elevation
Size
Initial
Breaking
Actual
Allowable
Required
Actual
No.
Tension
Load
T.
4 L
S.F.
S.F.
ft
K
K
K
K
L2
440.13 (A)
13/16 BS
8.00
80.00
33.15
48.00
1.000
1.448
(1587)
440.13 (B)
13116 BS
8.00
80.00
32.63
48.00
1.000
1.471 ✓
(1586)
440.13 (C)
13116 BS
8.00
80.00
32.87
48.00
1.000
1.460 ✓
(1585)
T1
397.25 (A)
11/16 EHS
5.00
50.00
20.07
30.00
1.000
1.495 ✓
(1600)
397.25 (A)
11/16 EHS
5.00
50.00
19.98
30.00
1.000
1.501 ✓
(1601)
397.25 (B)
11/16 EHS
5.00
50.00
19.74
30.00
1.000
1.520 ✓
(1594)
397.25 (B)
11/16 EHS
5.00
50.00
19.89
30.00
1.000
1.508 ✓
(1595)
397.25 (C)
11/16 EHS
5.00
50.00
19.98
30.00
1.000
1.502 ✓
(1588)
397.25 (C)
11116 EHS
5.00
60.00
19.90
30.00
1.000
1.507 ✓
(1589)
T4
339.67 (A)
11/16 8S
5.80
58.00
21.56
34.80
1.000
1.614 ✓
(1608)
339.67 (B)
11/16 BS
5.80
58.00
21.50
34.80
1.000
1.619 ✓
(1607)
339.67 (C)
11/16 BS
5.80
58.00
21.56
34.80
1.000
1.615 ✓
(1606)
T7
279.67 (A)
3/4 BS
6.80
68.00
25.70
40.80
1.000
1.587 ✓
(1611)
279.67 (B)
314 BS
6.80
68.00
25.78
40.80
1.000
1.582 ✓
(1610)
279.67 (C)
314 BS
6.80
68.00
25.74
40.80
1.000
1.585 ✓
(1609)
T10
219.67 (A)
11116 BS
5.80
58.00
26.73
34.80
1.000
1.302 ✓
(1614)
219.67 (B)
11/16 BS
5.80
58.00
26.75
34.80
1.000
1.301 ✓
(1613)
219.67 (C)
11/16 BS
5.80
58.00
26.69
34.80
1.000
1.304 ✓
(1612)
T13
179.67 (A)
13/16 BS
7.20
80.00
41.21
48.00
1.000
✓
(1617)
1.165
179.67 (B) 13/16 BS 7.20 80.00 41.21 48.00 1.000 1.165 ✓
Page 52
Rigorous Structural Analysis Report- Verizon.: 62713 - Spain Tower
CALTROP Corporation
July 17. 2015
Section Elevation Size Initial Breaking Actual Allowable Required Actual
No. Tension Load T. mT S.F. S.F.
ft K K K K
179.67 (C)
13/16
BS
7.20
80.00
41.14
48.00
1.000
1/
(1615)
1.167
T15 137.33 (A)
13/16
BS
7.20
80.00
44.77
48.00
1.000
9/
(1623)
1 072
137.33 (B)
13/16
BS
7.20
80.00
44.76
48.00
1.000
(1622)
1.072
137.33 (C)
13/16
BS
7.20
80.00
44.75
48.00
1.000
1/
(1618)
1.073
T18 70.33 (A)
13/16
BS
7.20
80.00
41.05
48.00
1.000
V
(1629)
1.169
70.33 (B)
13/16
B& -
7.20
80.00
41.06
48.00
1.000
V(1628)-
'.
1.169
'. 70.33 (C)
13/16
BS
. 7.20
80.00
41.05
48.00
1.000
' (1624)
-
1.169
Compression Checks
Leg
Design
Data (Compression)
Section
Elevation
Size
L
L„
K11r
A
Mast
P.
mp„
Ratio
No.
Stability
P.
It
ft
/t
inz
Index
K
K
TpT
L1
480 - 460
1 112
20.00
1.65
52.7
1.7672
0.98
-9.54
63.83
0.149
K=1.00
L2
460 - 440
2SR + Half 2XX
20.00
1.65
35.5
4.2400
0.85
-51.69
148.21
0.349'
Pipe
K=1.00
L3
440-420
2SR+Half 2STD
20.00
1.65
37.3
3.6700
0.98
-61.25
146.33
0.419'
Pipe
K=1.00
L4
420-400
21/2
20.00
1.65
31.6
4.9087
0.98
-100.97
202.09
0.500'
K=1.00
V
Tt
400-380
21/4
20.00
2.33
49.8
3.9761
1.00
-70.22
149.27
0.470'
K=1.00
V
T2
380 - 360
2
20.00
2.33
56.0
3.1416
1.00
-69.44
112.40
0.618'
K=1.00
V
T3
360 - 340
2
20.00
2.33
56.0
3.1416
1.00
-85.58
112.40
0.761 '
K=1.00
V
T4
340 - 320
2
20.00
2.33
56.0
3.1416
1.00
-90.26
112.40
0.803,
K=1.00
V
T5
320 -300
2
20.00
2.33
56.0
3.1416
1.00
-92.87
112.40
0.826 '
K=1.00
t/
T6
300 -280
2
20.00
2.33
56.0
3.1416
1.00
-110.83
112.40
0.986,
K=1.00
V
T7
280 - 260
2 114
20.00
2.33
49.8
3.9761
1.00
-113.10
149.27
0.758'
K=1.00
V
T8
260-240
21/4
20.00
2.33
49.8
3.9761
1.00
-83.58
149.27
0.560'
K=1.00
V
T9
240 - 220
2 114
20.00
2.33
49.8
3.9761
1.00
-74.34
149.27
0.498'
Page 53
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Section
Elevation
Size
L
L.
KUr
A
Mast
P.
pP„
Ratio
No.
Stability
P.
/t
R
R
in2
Index
K
K
mp„
K=1.00
T10
220 - 200
2 114
20.00
2.33
49.8
3.9761
1.00
-109.98
149.27
0.737'
K=1.00
6/
Ttt
200-192.6
21/4
7.60
2.39
61.0
3.9761
1.00
-109.31
147.98
0.739'
K=1.00
V
T12
192.5 - 180
2 1/4
12.50
2.30
49.1
3.9761
1.00
-99.36
150.04
0.6621
K=1.00
V
T13
180-160
21/2
20.00
2.33
44.8
4.9087
1.00
-116.78
190.74
0.612'
K=1.00
6/
T14
160 - 140
21/2
20.00
2.33
44.8
4.9087
1.00
-115.80
190.74
0.607 '
K=1.00
V
T15
140 - 120
21/2
20.00
2.33
44.8
4.9087
1.00
-144.76
190.74
0.769 '
K=1.00
V
T16
120 - 100
21/2
20.00
2.33
44.8
4.9087
1.00
-176.15
190.74
0.9231
K=1.00
I/
T17
100-80
21/2
20.00
2.33
44.8
4.9087
1.00
-175.47
190.74
0.920'
K=1.00
V
T18
80-60
21/2
20.00
2.33
44.8
4.9087
1.00
-147.58
190.74
0.774'
K=1.00
V
T19
60-40
2112
20.00
2.33
44.8
4.9087
1.00
-183.54
190.74
0.962'
K=1.00
V
T20
40 - 20
2 112
20.00
2.33
44.8
4.9087
1.00
-187.47
190.74
0.983'
K=1.00
6/
T21
20-4.66667
21/2
15.33
2.33
44.8
4.9087
1.00
-174.09
190.74
0.913'
K=1.00
V
T22
4.66667-0
21/2
5.21
1.24
23.8
4.9087
0.95
-153.66
200.51
0.766'
K=1.00
V
P � if �P, controls I L P Y
Diagonal Design Data (Compression)
Section
Elevation
Size
L
L
K11r
A
P„
�P„
Ratio
No.
P
R
tt
R
0
K
K
W.
L1
480 -460
112
2.59
1.21
81.6
0.1963
-0.63
4.48
0.141
K=0.70
V
L2
460-440
0.5625SR + 0.75SR
2.59
1.16
57.5
0.6800
-2.68
18.51
0.145'
K=0.70
V
L3
440 - 420
9116
2.59
1.18
70.4
0.2485
-1.64
6.20
0.264'
K=0.70
`/
L4
420 -400
3/4
2.59
1.16
52.0
0.4418
-2.75
12.42
0.222 '
K=0.70
V
T1
400-380
7/8
4.63
2.21
84.7
0.6013
-1.24
13.35
0.093'
K=0.70
(/
T2
380 - 360
3/4
4.63
2.22
99.4
0.4418
-1.44
8.61
0.169'
K=0.70
V
T3
360 - 340
3/4
4.63
2.22
99.4
0.4418
-2.48
8.51
0.292 '
K=0.70
Page 54
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Section Elevation Size L L„ KUr A P. Wn Ratio
No. P.
ft ft it ins K K hP-
T4
340 - 320
314
4.63
2.22
99.4
0.4418
-0.85
8.51
0.100'
K=0.70
`/
T5
320 - 300
314
4.63
2.22
99.4
0.4418
-2.20
8.51
0.258'
K=0.70
V
T6
300 - 280
3/4
4.63
2.22
99.4
0.4418
-3.07
8.51
0.361 '
K=0.70
t/
T7
280 - 260
314
4.63
2.21
98.9
0.4418
-3.72
8.56
0.436'
K=0.70
V
T8
260 -240
3/4
4.63
2.21
98.9
0.4418
-3.65
8.56
0.427 '
K=0.70
V
T9
240 - 220
3/4
4.63
2.21
98.9
0.4418
-4.12
8.56
0.481 '
K=0.70
V
T10
220-200
314
4.63
2.21
98.9
0.4418
-4.39
8.56
0.513'
K=0.70
V
T11
200 - 192.5
3/4
4.66
2.22
99.5
0.4418
-4.33
8.50
0.510 '
K=0.70
V
T12
192.5 - 180
3/4
4.61
2.20
98.5
0.4418
-8.81
8.59
1.026'
K=0.70
x
4.9-3 (1.03 CR) - 1017
T13
180 - 160
314
4.63
2.19
98.3
0.4418
-5.36
8.60
0.623'
K=0.70
6/
T14
160 - 140
314
4.63
2.19
98.3
0.4418
-7.18
8.60
0.835'
K=0.70
t/
T15
140 - 120
3/4
4.63
2.19
98.3
0.4418
-7.41
8.60
0.861 '
K=0.70
V
T16
120 - 100
3/4
4.63
2.19
98.3
0.4418
-6.37
8.60
0.740'
K=0.70
V
T17
100 - 80
314
4.63
2.19
98.3
0.4418
-7.33
8.60
0.852 '
K=0.70
T18 ••
80-60
3/41,
4.63
2.19
98.3
0.4418
-7.82
8.60
0.909'
T19
60 - 40
3/4
4.63
2.19
98.3
0.4418
-6.75
8.60
0.784'
K=0.70
V
T20
40 - 20
3/4
4.63
2.19
98.3
0.4418
-5.34
8.60
0.621 '
K=0.70
`/
T21
20 - 4.66667
3/4
4.63
2.19
98.3
0.4418
-8.85
8.60
1.029'
K=0.70
�(
4.9-3 (1.03 CR) - 1526
T22
4.66667 - 0
3/4
1.76
1.06
47.4
0.4418
-5.94
12.72
0.467 '
K=0.70
V
Secondary Horizontal Design Data (Compression)
Section Elevation Size L L. KI/r A P. rpP„ Ratio
No. P.
ft It ft in' K K AP -
Page 55
Rigorous Structural Analysis Report- Verizon: 61713 - Spain Tower July 17, 2015
CALTROP Corporation
Section
Elevation
Size
L
L„
KI/r
A
P.
¢P„
Ratio
No.
P
/t
It
R
inz
K
K
p.
L2
460 - 440
3/4
2.00
1.80
80.5
0.4418
-0.90
12.38
0.072
K=0.70
`/
T11
200 - 192.5
3/4
4.00
3.81
170.8
0.4418
-1.89
3.42
0.5531
K=0.70
6/
Top Girt Design Data
Compression
Section
Elevation
Size
L
L„
KI1r
A
P„
�P„
Ratio
No.
P
R
It
R
in'
K
K
WP
Ll
480 - 460
3/4
2.00
1.88
84.0
0.4418
-0.04
11.87
0.003
K=0.70
V
L2
460 - 440
3/4
2.00
1.80
80.5
0.4418
-0.01
12.38
0.001 '
K=0.70
V
T2
380- 360
1
4.00
3.83
128.8
0.7854
-0.03
10.70
0.0021
K=0.70
6/
T3
360 - 340
1
4.00
3.83
128.8
0.7854
-0.28
10.70
0.026 '
K=0.70
V
TS
320 - 300
1
4.00
3.83
128.8
0.7854
-0.02
10.70
0.002 '
K=0.70
6/
T6
300 - 280
1
4.00
3.83
128.8
0.7854
-0.61
10.70
0.057 '
K=0.70
T8
260 -240
1
4.00
3.81
128.1
0.7854
-1.01
10.81
0.094 '
K=0.70
`/
T9
240 -220
1
4.00
3.81
128.1
0.7854
-0.35
10.81
0.032 '
K=0.70
`/
T11
200 - 192.5
1
4.00
3.81
128.1
0.7854
-0.14
10.81
0.0131
K=0.70
V
T14
160 - 140
1
4.00
3.79
127.4
0.7854
-0.32
10.93
0.029'
K=0.70
V
T15
140 - 120
1
4.00
3.79
127.4
0.7854
-1.43
10.93
0.130 '
K=0.70
V
T16
120 -100
1
4.00
3.79
127.4
0.7854
-1.61
10.93
0.147'
K=0.70
T17
100 - 80
1
4.00
3.79
127.4
0.7854
-0.07
10.93
0.007'
K=0.70
V
T18
80-60
1
4.00
3.79
127.4
0.7854
-2.34
10.93
0.214'
K=0.70
V
T19
60 - 40
1
4.00
3.79
127.4
0.7854
-1.67
10.93
0.163 '
K=0.70
V
T21
20 - 4.66667
1
4.00
3.79
127.4
0.7854
-1.07
10.93
0.098'
K=0.70
V
1 P. I �P cOntrols
Page 56
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower July 17, 2015
CALTROP Corporation
Bottom Girt Design Data
Compression
Section
Elevation
Size
L
L„
KI/r
A
P.
OP„
Ratio
No.
P�
R
it
R
inr
K
K
Tp�
Ll
480 -460
7/8
2.00
1.88
72.0
0.6013
-0.14
18.52
0.007
K=0.70
V
L3
440 - 420
"' 7/8
2.00
1.82
69.9
0.6013
-0.17
18.93
0.009'
•
' '
K=0.70
L4
420; 400
7/8
2.00
1.79
68.8
0.6013
-0.36
19.14
0.019,
K=0.70
`/
T1
400-380
1
4.00
3.81
128.1
0.7854
-0.04
10.81
0.004'
K=0.70
V
T2
380- 360
1
4.00
3.83
128.8
0.7854
-0.44
10.70
0.041'
K=0.70
`/
T3
360 - 340
1
4.00
3.83
128.8
0.7854
-0.98
10.70
0.092'
K=0.70
`/
T5
320 -300
1
4.00
3.83
128.8
0.7854
-0.63
10.70
0.059 '
K=0.70
T6
300- 280
1
4.00
3.83
128.8
0.7854
-0.86
10.70
0.080 '
K=0.70
`/
T7
280 -260
1
4.00
3.81
128.1
0.7854
-0.64
10.81
0.059 '
K=0.70
T8
260 - 240
1
4.00
3.81
128.1
0.7854
-0.11
10.81
0.010'
K=0.70
V
T9
240- 220
1
4.00
3.81
128.1
0.7854
-0.47
10.81
0.044 '
K=0.70
`/
T12
192.5- 180
1
4.00
3.81
128.1
0.7854
-1.32
10.81
0.122 '
K=0.70
T14
160 - 140
1
4.00
3.79
127.4
0.7854
-2.57
10.93
0.235 '
K=0.70
V
T15
140 -120
1
4.00
3.79
127.4
0.7854
-1.94
10.93
0.177 '
K=0.70
I/
T17
100 - 80
1
4.00
3.79
127.4
0.7854
-2.12
10.93
0.194'
K=0.70
V
T18
80 - 60
1
4.00
3.79
127.4
0.7864
-2.26
10.93
0.206'
K=0.70
V
T19
60-40
1
4.00
3.79
127.4
0.7864
-0.37
10.93
0.034'
K=0.70
T20
40 - 20
1
4.00
3.79
127.4
0.7854
-0.97
10.93
0.089'
K=0.70
V
1 P. / �P„ controls
Mid Girt Design Data
Compression
Section Elevation Size L L„
KI/r A P.
¢p„
Ratio
No.
P.
R R tt
inz K
K
�P
Lt 480 - 460 3/4 2.00 1.88
84.0 0.4418 -0.02
11.87
0.002
K=0.70
Page 57
Rigorous Structural Analysis Report- Verson: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Section
Elevation
Size
L
L„
Kl/r
A
P.
opr
Ratio
No.
P.
it
it
ft
in'
K
K
TP7
L2
460 - 440
3/4
2.00
1.80
80.5
0.4418
-0.23
12.38
0.018
K=0.70
V
L3
440 - 420
314
2.00
1.82
81.6
0.4418
-0.05
12.22
0.004'
K=0.70
V
L4
420 - 400
3/4
2.00
1.79
80.3
0.4418
-0.27
12.41
0.022 '
K=0.70
V
1 P„ /op. controls
Top
Guy Pull -Off Design
Data (Compression)
Section
Elevation
Size L
L„ Mr A
P.
op
Ratio
No.
P.
ft
it
it in2
K
K
�P
T1
400 - 380
1 1/4 4.00
3.81 146.4 1.2272
-0.98
12.94
0.076
K=1.00
T13
180 - 160
1 1/4 4.00
3.79 146.6 1.2272
-1.50
13.08
0.115 '
K=1.00
V
1 P„ / oP„ controls
Bottom Des
Section
Elevation
Size
L
L„
KUr
A
P.
oP„
Ratio
No.
P.
it
it
ft
inr
K
K
oPn
T1
400 -380
2 1/4
4.59
4.48
95.6
3.9761
-16.21
79.61
0.191
(1592)
K=1.00
V
T1
400 - 380
2 1/4
4.59
4.48
95.6
3.9761
-15.17
79.61
0.191 '
(1693)
K=1.00
V
T1
400-380
21/4
4.69
4.48
95.6
3.9761
-16.03
79.61
0.189'
(1598)
K=1.00
V
T1
400 - 380
2 1/4
4.69
4.48
95.6
3.9761
-16.19
79.61
0.191 '
(1599)
K=1.00
II/
T1
400 - 380
2 114
4.59
4.48
95.6
3.9761
-15.21
79.61
0.191 '
(1604)
K=1.00
V
T1
400 - 380
2 1/4
4.59
4.48
95.6
3.9761
-15.34
79.61
0.193 '
(1605)
K=1.00
V
1 P. / op. controls
Tension Checks
Page 58
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17. 2015
CALTROP Corporation
Leg Design Data
Tension
Section
Elevation
Size L L„
KI1r
A
P.
+P„
Ratio
No.
P.
ft
ft It
id
K
K
�Pn
Ll
480 -460
1 1/2 20.00 0.13
4.0
1.7672
9.09
79.52
0.114
✓
L2
460-440
2SR+Half 2XX Pipe 20.00 1.65
35.5
4.2400
38.75
190.80
0.203'
✓
L3
"0-420
2SR+Half 2STD Pipe 20.00 1.65
37.3
3.6700
12.52
165.15
0.076'
✓
L4
420-400
21/2 20.00 0.13
2.4
4.9087
29.44
220.89
0.133'
✓
T1
400-380
21/4 20.00 0.33
7.1
3.9761
5.87
178.92
0.033'
1 P„ / mP„ controls
Dia oval Design
Data Tension
Section
Elevation
Size
L
L.
Kilt
A
P.
OP„
Ratio
No.
P.
If
If
ft
ins
K
K
TP7
•' L1 .,
.� 480' 460 ',
11/2i
2.59
1.21
116.6
0.1963
0.63
6.36
0.099
L2
460-440
-0.5625SR+0.75SR
2.59
1.16
82.1
0.6800
2.90
22.03
0.132'
✓
L3
440-420
9/16
2.59
1.18
100.6
0.2485
1.12
8.05
0.138'
✓
L4
420 - 400
3/4
2.59
1.16
74.3
0.4418
2.01
14.31
0.141 '
✓
T1
400 - 380
7/8
4.63
2.21
121.1
0.6013
0.94
19.48
0.048'
✓
T2
380 - 360
3/4
4.63
2.22
142.0
0.4418
1.12
14.31
0.078'
✓
T3
360 - 340
3/4
4.63
2.22
142.0
0.4418
2.18
14.31
0.152'
✓
T4
340 -320
3/4
4.63
2.22
142.0
0.4418
0.77
14.31
0.054 '
✓
T5
320 -300
314
4.63
2.22
142.0
0.4418
2.14
14.31
0.150 '
✓
T6
300 - 280
3/4
4.63
2.22
142.0
0.4418
2.97
14.31
0.208'
✓
T7
280 - 260
3/4
4.63
2.21
141.2
0.4418
3.27
14.31
0.228'
✓
T8
260 - 240
3/4
4.63
2.21
141.2
0.4418
3.13
14.31
0.219'
✓
T9
240 - 220
3/4
4.63
2.21
141.2
0.4418
3.66
14.31
0.256'
✓
T10
220- 200
3/4
4.63
2.21
141.2
0.4418
4.16
14.31
0.290 '
Page 59
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower July 17, 2015
CALTROP Corporation
Section
Elevation
Size
L
L„
Mr
A
P.
rVP„
Ratio
No.
P.
R
it
/t
in°
K
K
Wp
T11
200 - 192.5
3/4
4.66
2.22
142.1
0.4418
2.91
14.31
0.203
T12
192.5 -180
3/4
4.61
2.20
140.7
0.4418
6.56
14.31
0.458 '
4.9-3 (1.02 CR) -1018
T13
180- 160
314
4.63
2.19
140.5
0.4418
5.17
14.31
0.361'
T14
160 - 140
3/4
4.63
2.19
140.5
0.4418
6.41
14.31
0.448'
T16
140 - 120
3/4
4.63
2.19
140.5
0.4418
7.77
14.31
0.5431
T16
120- 100
3/4
4.63
2.19
140.5
0.4418
5.34
14.31
0.373 '
T17
100 - 80
3/4
4.63
2.19
140.5
0.4418
6.29
14.31
0.439 '
T18
80- 60
3/4
4.63
2.19
140.5
0.4418
6.98
14.31
0.487 '
T19
60- 40
3/4
4.63
2.19
140.5
0.4418
5.70
14.31
0.398 '
T20
40- 20
3/4
4.63
2.19
140.5
0.4418
4.10
14.31
0.286 '
T21
20 - 4.66667
3/4
4.63
2.19
140.5
0.4418
7.22
14.31
0.504'
4.9-3 (1.03 CR) -1527
T22
4.66667 - 0
3/4
3.43
1.84
117.5
0.4418
4.56
14.31
0.318'
Horizontal Design Data Tension
Section Elevation Size L L„ KUr A
P.
rbP„
Ratio
No.
P
it R R in'
K
K
gyp„
T12 192.5 -180 3/4 4.00 3.81 244.0 0.4418
2.97
19.88
0.149
1 P u / �P„ contrOls
Secondary
Horizontal Design Data Tension
Section
Elevation
Size
L L„ KUr A P.
�Pr
Ratio
No.
P
it
It It in° K
K
spa
L2
460 - 440
314
2.00 1.80 115.0 0.4418 0.90
19.88
0.045
T11
200 - 192.5
314
4.00 3.81 244.0 0.4418 1.89
19.88
0.095 '
Page 60
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower
CALTROP Corporation
July 17. 2015
Section Elevation Size L L Or A P. Ratio
No. P.
it R /t inz K K OP„
1 P„ / oP„ controls
Top Girt Design Data Tension
Section
Elevation
Size
L
Lv
Mr
A
P.
�P„
Ratio
No.
P.
/t
It
R
in2
K
K
TP„
L1
480 -460
3/4
2.00
1.88
120.0
0.4418
0.04
19.88
0.002
✓
L2
460 - 440
3/4
2.00
1.80
115.0
0.4418
0.02
19.88
0.0011
✓
L3
440-420
3/4
2.00
1.82
116.5
0.4418
1.42
19.88
0.072'
✓
L4
420 - 400
3/4
2.00
1.79
114.7
0.4418
0.25
19.88
0.013'
✓
T2
380 - 360
1
4.00
3.83
184.0
0.7854
0.35
35.34
0.010'
T3
360 - 340
1
4.00
3.83
184.0
0.7854
0.58
35.34
0.016'
T5
320 - 300
1
4.00
3.83
184.0
0.7854
0.28
35.34
0.008'
✓
T6
300 -280
1
4.00
3.83
184.0
0.7854
0.77
36.34
0.022 '
-'
T8
260.240
.. 1 ?
4.00
3.81
183.0
0.7854
1.17
35.34
0.033'
T9
240 - 220
1
4.00
3.81
183.0
0.7854
0.56
35.34
0.016'
✓
T11
200 - 192.5
1
4.00
3.81
183.0
0.7854
0.83
35.34
0.023'
✓
T14
160 - 140
1
4.00
3.79
182.0
0.7854
1.08
35.34
0.031 '
✓
T15
140 - 120
1
4.00
3.79
182.0
0.7854
2.36
35.34
0.067'
✓
T16
120 - 100
1
4.00
3.79
182.0
0.7854
2.53
35.34
0.071 '
✓
T17
100 - 80
1
4.00
3.79
182.0
0.7854
1.09
35.34
0.031 '
✓
T18
80 - 60
1
4.00
3.79
182.0
0.7854
3.58
35.34
0.101 '
✓
T19
60 - 40
1
4.00
3.79
182.0
0.7854
2.99
35.34
0.085'
✓
T20
40 - 20
1
4.00
3.79
182.0
0.7864
0.85
35.34
0.024'
✓
T21
20 - 4.66667
1
4.00
3.79
182.0
0.7854
2.65
35.34
0.075'
✓
T22
4.66667 - 0
1
3.71
3.51
168.3
0.7854
31.16
35.34
0.882 '
Page 61
Rigorous Structural Analysis Report- Verizon: 62713-Spain Tower July 17, 2015
CALTROP Corporation
Section Elevation Size L L Mr A P. QP„ Ratio
No. P.
R H R in' K K mP„
1 P„ /�P„controls
Bottom Girt Design Data Tension
Section
Elevation
Size
L
L
K11r
A
P.
rbP
Ratio
No.
P
it
/t
/t
inz
K
K
�Pn
L1
480 - 460
718
2.00
1.88
102.9
0.6013
0.14
27.06
0.005
L3
440 - 420
7/8
2.00
1.82
99.9
0.6013
0.33
27.06
0.012 '
L4
420 - 400
718
2.00
1.79
98.3
0.6013
0.53
27.06
0.020'
T1
400 -380
1
4.00
3.81
183.0
0.7854
0.31
35.34
0.009 '
T2
380- 360
1
4.00
3.83
184.0
0.7854
0.59
35.34
0.017 '
T3
360- 340
1
4.00
3.83
184.0
0.7854
1.25
35.34
0.035 '
T4
340 - 320
1
4.00
3.83
184.0
0.7854
0.26
35.34
0.007'
TS
320 - 300
1
4.00
3.83
184.0
0. � �.
PO4�y
T6
300-280
1
4.00
3.83
184.0
0. 54
T7
280 - 260
1
4.00
3.81
183.0
0.7854
1.44
35.34
0.041 '
T8
260 - 240
1
4.00
3.81
183.0
0.7854
0.94
35.34
0.026'
T9
240- 220
1
4.00
3.81
183.0
0.7854
1.66
35.34
0.044'
T10
220-200
1
4.00
3.81
183.0
0.7854
0.78
35.34
0.022'
T12
192.5 -180
1
4.00
3.81
183.0
0.7854
4.01
35.34
0.113 '
T13
180 - 160
1
4.00
3.79
182.0
0.7854
0.96
35.34
0.027 '
T14
160 - 140
1
4.00
3.79
182.0
0.7854
3.56
35.34
0.101'
T15
140 - 120
1
4.00
3.79
182.0
0.7854
3.13
35.34
0.089'
T16
120 - 100
1
4.00
3.79
182.0
0.7854
0.58
35.34
0.016 '
T17
100 - 80
1
4.00
3.79
182.0
0.7854
3.07
36.34
0.087 '
T18
80- 60
1
4.00
3.79
182.0
0.7864
3.19
35.34
0.090,
Page 62
Rigorous Structurat Analysis Report- Verizon: 627/3 - Spain Tower July 17, 2015
CALTROP Corporation
Section Elevation Size L L„ KI/r A P„ Ratio
No. P
inz K K �P
T19
60-40 1
4.00
3.79
182.0
0.7854
1.13
35.34
0.032'
T20
40 - 20 1
4.00
3.79
182.0
0.7854
1.69
35.34
0.048'
T21
20 - 4.66667 1
4.00
3.79
182.0
0.7854
10.86
35.34
0.307'
T22
4.66667 - 0 1
0.86
0.65
31.1
0.7854
5.01
36.34
0.142'
I P„ / �P„ controls
_.....__ .. r_ __.Mid.Girt Desi n,Data, Tension _.._.
Section
Elevation
Size
L
L„
MY
A
P.
¢P„
Ratio
No.
P.
ft
It
ft
inz
K
K
WP
L1
480 - 460
3/4
2.00
1.88
120.0
0.4418
0.03
19.88
0.001
L2
460 - 440
314
2.00
1.80
115.0
0.4418
0.26
19.88
0.013'
L3
440 - 420
3/4
2.00
1.82
116.5
0.4418
0.47
19.88
0.023'
L4
420 - 400
3/4
2.00
1.79
114.7
0.4418
0.63
19.88
0.032'
T1
, 400 ,380
1 ,.
4.00
3.81
183.0
0.7854
0.45
35.34
0.013'
T2
380 - 360
1
4.00
3.83
184.0
0.7854
0.40
36.34
0.011 '
✓
T3
360 - 340
1
4.00
3.83
184.0
0.7854
0.44
35.34
0.012 '
✓
T4
340 -320
1
4.00
3.83
184.0
0.7854
0.50
35.34
0.014 '
✓
T5
320 -300
1
4.00
3.83
184.0
0.7854
0.52
35.34
0.015 '
✓
T6
300 - 280
1
4.00
3.83
184.0
0.7854
0.59
35.34
0.017'
✓
T7
280 - 260
1
4.00
3.81
183.0
0.7854
0.66
35.34
0.019'
✓
T8
260 - 240
1
4.00
3.81
183.0
0.7854
0.57
35.34
0.016'
✓
T9
240 - 220
1
4.00
3.81
183.0
0.7854
0.62
35.34
0.018 '
✓
T10
220-200
1
4.00
3.81
183.0
0.7854
0.91
35.34
0.026'
1 P„ / �P„ controls
Page 63
J
Rigorous Structural Analysis Report- Verizon: 62713 - Spain Tower July 17, 2015
CAL TROP Corporation
Top Guy
Pull -Off Design
Data
Tension
Section
Elevation
Size
L
L„
KI1r
A
P.
Ratio
No.
P.
R
/t
It
ins
K
K
TPT
L2
460 - 440
1 1/4
2.00
1.80
69.0
1.2272
6.02
39.76
0.151
Tt
400 - 380
1 114
4.00
3.81
146.4
1.2272
1.20
39.76
0.030'
I✓
T4
340 - 320
1 114
4.00
3.83
147.2
1.2272
7.22
39.76
0.182 '
T7
280-260
11/4
4.00
3.81
146.4
1.2272
8.93
39.76
0.225'
I✓
T10
220-200
11/4
4.00
3.81
146.4
1.2272
10.69
39.76
0.269'
T13
180 -160
1 114
4.00
3.79
145.6
1.2272
19.29
39.76
0.485'
T15
140 -120
1 1/4
4.00
3.79
145.6
1.2272
17.44
39.76
0.439'
T18
80-60
11/4
4.00
3.79
145.6
1.2272
18.88
39.76
0.475'
1 P. / �P„ Controls
Torque -Arm Top Design Data.. .
Section Elevation Size L L„ KI1r � fi �,�,I,P„ „��R�ia
No. a �^'"
T1
400-380
21/4
4.67
4.56
97.4"
3.578T- -�W84�
'4g8.82
(M31'
(1590)
`/
T1
400 - 380
2 114
4.67
4.56
97.4
3.9761
16.89
128.82
0.131 '
(1591)
V
Tt
400-380
21/4
4.67
4.56
97.4
3.9761
17.08
128.82
0.133'
(1596)
V
T1
400-380
21/4
4.67
4.56
97.4
3.9761
17.09
128.82
0.133'
(1597)
V
T1
400-380
21/4
4.67
4.56
97.4
3.9761
16.95
128.82
0.132'
(1602)
V
T1
400-380
21/4
4.67
4.56
97.4
3.9761
16.99
128.82
0.132'
(1603)
1/
1 P„ / ¢P„ controls
Section Capacity Table
Page 64
Rigorous Structural Analysis Report- Yerizon: 62713 - Spain Tower July 17, 2015
CALTROP Corporation
Section
Elevation
Component
Size
Critical
P
oP�
%
Pass
No.
R
Type
Element
K
K
Capacity
Fail
Lt
480 - 460
Latticed Pole Leg
1 112
3
-9.54
63.83
14.9
Pass
L2
460 - 440
Latticed Pole Leg
2SR + Half 2XX Pipe
87
-51.69
148.21
34.9
Pass
L3
440 - 420
Latticed Pole Leg
2SR + Half 2STD Pipe
207
-61.25
146.33
41.9
Pass
L4
420 - 400
Latticed Pole Leg
21/2
291
-100.97
202.09
50.0
Pass
L1
480-460
Latticed Pole
1/2
16
-0.63
4.48
14.1
Pass
Diagonal
L2
460-440
Latticed Pole
0.5625SR+0,75SR
101
-2.68
1&51
14.5
Pass
Diagonal
L3
440 - 420
Latticed Pole
9/16
221
-1.64
6.20
26.4
Pass
Diagonal
L4
420 - 400
Latticed Pole
3/4
305
-2.75
12.42
22.2
Pass
Diagonal
L2
460 - 440
Latticed Pole
3/4
104
-0.90
12.38
7.2
Pass
Secondary
Horizontal
L1
480 - 460
Latticed Pole Top
314
4
-0.04
11.87
0.3
Pass
Girt
L2
460 - 440
Latticed Pole Top
3/4
90
-0.01
12.38
0.1
Pass
Girt
L3
440 - 420
Latticed Pole Top
3/4
208
1.42
19.88
7.2
Pass
Girt
L4
420 - 400
Latticed Pole Top
3/4
292
0.25
19.88
1.3
Pass
Girt
L1
480-460
Latticed Pole
7/8
7
-0.14
18.52
0.7
Pass
Bottom Girt
L3
440 - 420
Latticed Pole
718
212
0.33
27.06
1.2
Pass
Bottom Girt
L4
420 - 400
Latticed Pole
7/8
295
0.53
27.06
2.0
Pass
Bottom Girt
L1
480 - 460
Latticed Pole Mid
314
12
-0.02
11.87
0.2
Pass
Girt
L2
460 - 440
Latticed Pole _Mid
3/4
94
-0.23
12.38
1.8
Pass
Girt
0.,
:440-420.
Latticed. Pole Mid
3/4
214
0.47
19.88
2.3
Pass
-
Girt d '.
L4
'420-_400
Latticed:Pole Mid
3/4
300
0.63
19.88
3.2
Pass
Girt
T1
400 - 380
Leg
2 1/4
375
-70.22
149.27
47.0
Pass
T2
380 - 360
Leg
2
435
-69.44
112.40
61.8
Pass
T3
360 - 340
Leg
2
495
-85.58
112.40
76.1
Pass
T4
340 - 320
Leg
2
555
-90.26
112.40
80.3
Pass
T5
320 - 300
Leg
2
615
-92.87
112.40
82.6
Pass
T6
300 - 280
Leg
2
675
-110.83
112.40
98.6
Pass
T7
280 - 260
Leg
2 114
735
-113.10
149.27
75.8
Pass
T8
260 - 240
Leg
2 114
795
-83.58
149.27
56.0
Pass
T9
240 - 220
Leg
2 114
855
-74.34
149.27
49.8
Pass
T10
220 - 200
Leg
2 114
915
-109.98
149.27
73.7
Pass
T11
200 - 192.6
Leg
2 1/4
975
-109.31
147.98
73.9
Pass
T12
192.5 - 180
Leg
2 1/4
1008
-99.36
150.04
66.2
Pass
T13
180 - 160
Leg
21/2
1058
-116.78
190.74
61.2
Pass
T14
160-140
Leg
21/2
1115
-115.80
190.74
60.7
Pass
T15
140 - 120
Leg
21/2
1172
-144.76
190.74
75.9
Pass
T16
120 - 100
Leg
21/2
1229
-176.15
190.74
92.3
Pass
T17
100 - 80
Leg
2 112
1286
-175.47
190.74
92.0
Pass
T18
80-60
Leg
21/2
1343
-147.68
190.74
77.4
Pass
T19
60-40
Leg
21/2
1400
-183.54
190.74
96.2
Pass
T20
40 - 20
Leg
21/2
1467
-187.47
190.74
98.3
Pass
T21
20 - 4.66667
Leg
21/2
1514
-174.09
190.74
91.3
Pass
Page 65
N N N N 0 0 N N 0 N N N X 22 N N N N N .x N N N
@ @ @ @ @ @ — @ @ @
0. aaao.aaaaaa.a LLaaamm mm LLaaa
Ur m a M m N O m- N n- M OCR M H - o N m Q- rn n m M
@ tC N fG O> O H 6 6 (V 00 N N C) 6� N O N N N fG 4 N � n ^m N N MQQQ Nm� mmm nmrnnm� Q uI
U m
Y
Y
N
0
W
m m mmm O m O O O O O O O O O N m N
M N N iN.6 N h to N m N m mmmmmmmmm nmQ
� m .6 m m m m m m m m m m m m m m m m m c� M
Q Q m N O n N M N O 7 rn M m m n M N m Q In Q n m
N Q Q m n f0 M M m M 7Q M M m n M m m pr m
N O N T T T v C V T N 1r n m Ir n 9 hC? h N-
O m m M n n O N n r0 n O N N m m rn N fn0 Nm m
m
��
m Q Q v a Q a Q Q Q Q Q Q a Q Q Q Q Q a v g v e
N N N N N N N N N N N f/1 N rll rll (A y N N N Ni N N N N N N N N NIl
N N N N N N N N N N N N Vl 1/ Vl N
@ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @
a 0.
11�3
O m m n - .-. O n- V M Q m N m- N n m O m m Q N" n N r m
1N C N M IV ti "i N N m 2 6 0 6 G N <O N fV V N"- N
Q o Q o Q M M Q M M Q M Q Q o o Q o o Q Q Q M M Q
M n M I,:m M rn m M m m M m M M n n M n n m M m M m M m m M
m C N o m C IA 0 0 Y) O O N O to N G O H C O O N O UI O N G C In
lA m m
M N-N r0 O M m p Q (D p M m pp O 7 m N O m mQ n M rn N q m
O Oi C Ql�l, 8 Qp� N O O O O O O p O p 0 N p
m 10 n m � 1n M O n M n m m O m m Q M O m N
Q Q�om�.- M QQv�mmn nmrn ��
m m m m m m m m !0 m m !0 m m N N m N N N m NW-@Z- Y CCCC CYY CY r C C C C C C C C 0r C Y C C
U(7
a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (7 (7 (7 (7 (9 (7 o E E E E E E E E E E E E E E E
m m m m m m m m m m m m mmmmmmmmm m N N¢ c n n n¢ n¢¢¢¢ n n n n n o 0 0 0 0 0 0 0 0 0 0 0 0 0 0
A m m A m m A m m g m m m A m A m m m m w-F 0.. o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0� z 9 29 19 29 a�� 29� r
0000000000000'00'00'0'0'o'oo=N=9PF-F-99121299129�99�00o0o0000000000
m m m m m m m m m m m m m m m
G n M M M M M N N N Om m Q N m Gn M M M O tO 0N NC N 0 N m V N O OSD O N O
NN f0 Q N m n M M M M M N N N N N
� O mo lOD V N O W (Op < N O N W t00 C N�� tOD C� fm0 N O W t00 N O t00 C O tOO ' N�� t00 a a N O� t00 O N O N N V N N m fOD � N
�-
N � N
N M Q N m n m m O � N M Q H m n m rn 0 � N N •- N M h m m m '- ^ 1(J fO n m m 0 .- N � N M Q r(1 m n m rn O N M Q N m
F I-HFf HHf HF. F. F. F. F.F F. F. F.FHFN- IN-F-F- Hf Hf HHf-f HHFHHHHHF-F-F-F-F-F F-H F'FHHI-/-F
A Gr � ��fN
�m �V
cn
t` o
m� m
W-Imi AW O
m m w O O tp
N
A + + N N W A A ++ N N W�A 'A' ++ N N W A A ++ N N W A A N N N N W W W W w A p 0
O W A m N N A O m m
o O O O o o O
m
O
o O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O rn A 0 0 0 0
q
O O O O O O O O 0 0 0 0 0 0 0 G
j
3 q
0 0 0 O O O O O O O O O O O O O O O O O O O O O O O O W
O
V
o
m m WG
r(mP7.��e0o0o0o0o0o0oOo
.�.(4m2ij
riDP�
a
0n�(l-a-pnG0 Gapp000000
) ) ,n@ a¢ann.am
0Ql
(wPi(DVeij iD��D�rDP 0W
n0(0 0oo
@(VwQi(mgi ncPo nWP (DP�(y�(DP7aaan
Itican3
O
o G)GnLG7G)W WCCmC Of0
m
ry
�.
W W m W
W W V V V V' N' T' W W V
V V V m N W W V V M V m"
N
V
a"
N + + + + t\ t\t W -_ W .. (\ W W W W W S W` W .. (J +++++ -••+ ++++++++
A A A A A A A
N
f
A A A A A m O m m m m m m m m m W m m m m m m moo
0
i
m m m O t0 V m W O m m m m m m m m m m m m m m m m 888 m m m m
m
V V N A m m N O m m m m N m W O V m m f0 W V A+ m 0 V N W W W W m N m O m tD
n
O m A fJ m W N l0 N G V m V m b m 0 V N V V in m m 0 V N V V fn O+ O m m m m m m> A A O tp N
f0 m A O t0 m m m A (D A m m V m m+ m m 0 O N V m t0 N O A A O m+
T
W m V+ W O m V m' m N N m N
N W w w W W W + W A A A W A w W A A A A W A W W A A A A w A W W A W W w w W W W W w w W W++++
m fO N N t0 t0 t0 N O m m m A A O W m m m A 0 A O m m m m A 0 A O m m m m m m m m w m m 0 0 0 0
a
m m m m m m A m O O O O O O O O O O O O O O O O O O O O O O O O A A A A A A A A A 'A 'A A Iml W W W N
N
A A A N N N+ V + m tD m V m m m m m tD m V m m m m m p m V m m m m N+. ++ ++
W V W m m N V m m (l� W 41 m W m m N W 41 m w m N m W VI m W m tp
n
r
N V m t' m A
A
V
v
�
O
U
V V V
N N N N N N
N N tNll (NIl rN/1 N N N N N N N N N N N 41 N N r/I N N N N N N N N N N
�y
(N/� N N N N N N N f/I N 41 N N
w
Rigorous Structural Analysis Report— Verizon: 62713 - Spain Tower
CALTROP Corporation
July 17. 2015
Section Elevation Component size Critical P op, % Pass
No R Type Element K K Capacity Fail
T1 400-380 Torque Arts 21/4 1605 -15.34 79.61 19.3 Pass
Bottom@397.25
i
b.r. b.h •:rr
Page 68
Summary
Latticed
50.0
Pass
Pole Leg
(L4)
Latticed
26.4
Pass
Pole
Diagonal
(L3)
Latticed
7.2
Pass
Pole
Secondary
Horizontal
(L2)
Latticed
7.2
Pass
Pole Top
Girt (L3)
Latticed
2.0
Pass
Pole
Bottom Girt
(L4)
Latticed
3.2
Pass
Pole Mid
Girt (L4)
Leg (T6)
98.6
Pass
Diagonal
102.9
Fail x
(T21)
Horizontal
14.9
Pass
(T12)
Secondary
55.3
Pass
n oral
1)
Girt
88.2
Pass
22)
Bottom Girt
30.7
Pass
(T21)
Mid Girt
2.6
Pass
(T1o)
Guy A
93.3
Pass
(T15)
Guy B
93.3
Pass
(T15)
Guy C
93.2
Pass
(T15)
Top Guy
48.5
Pass
Pull -Off
(T13)
Torque
13.3
Pass
Ann Top
(Tt)
Torque
19.3
Pass
Ann
Bottom
(T1)
Bolt
87.2
Pass
Checks
RATING =
102.9
Acceptable
c
m
N
N
2
-
N p
w
N N
w
N
�
Jp
N
N
'
F
N
Z
F
N
2
a
p
4 N
N N
N
Z
a
2
`
p
N
c
E
2y
d
i
F
a
rc
"
u
o
LL
p
w
-
z
z
®
o
e
N
6
i
C
N
5
4
�.,
z
p
6 z
N
i
-
rc
N
z
i
p
N
K
Z
5
x
d
9G4
si£
R-250.00 R
SIZE
F Fu
� xw
rIA-222-G Standard.
ALL REACTIONS ARE FACTORED
CALTROP Corporation
3400 Lakeside Drive, Suite 525
Miramar, FL 33027
Phone:(954)874-7879
FAX: 954 8747868
: 62713 -Spain Tower
P-J-': 130-752.43
cI'°"L Vedzon o'a`'°' °r Michael A. Phillips, P
APod:
coae: TIA-22243 °a'a 07/17/15
s�Ia: NTS
P.M:I
Dx N.-r-1