Loading...
HomeMy WebLinkAboutPLANSENGINEERING REVIEW.• BOAT LIFT MOUNTING BRACKETS AND SPECIFIED MOUNTING HARDWARE COMPLY WITH WIND LOAD REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE, PER ASCE 7, AND PER DESIGN LOAD REQUIREMENTS OF THE 2010 ALUMINUM ASSOCIATION'S DESIGN MANUAL. MOUNTING BRACKETS INSTALLED PER HI-77DE INS7RUC77ONS, WILL EXCEED UL77MATE DESIGN WIND SPEED OF 170 Mf (EXPOSURE CATEGORY C OR D) TO BE REMOVED FROM BOAT TO A MAJOR WIND EVENT. PILINGS PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB -SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 2014. ALL PILINGS TO BE 10" MINIMUM DIAMETER 2.5 C.C.A PRESSURE TREATED WOOD, PRE -STRESSED CONCRETE OR COMPARABLE EQUIVALENT. SEAWALL . THE CONTRACTOR SHALL VERIFY SEAWALL CAPACITIES TO COMPLY W I T H F B C 2 0 1 4. NOTE TO EXAMINER, THIS CER77RED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY.• ROGER BABER P.E. NO. 43855 MCR PROFESSIONAL ENGINEERING C.A. NO. 26967 8528 SW KANSAS AVE. STUART, FL 3 PILING MOUNTING MINIMUM (2) 5/8- DIA THREADED ROD PER MOUNT REQUIRED FOR MOUN77NG ALTERNATE SEAWALL MOUNTING MINIMUM (2) 5/6' DIA ANCHORS REQUIRED FOR MOUN77NG