FL14645-R2
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Produa Manufacturer
Metal Sales Manufacturing Corporation
Address/Phone/Emad
545 South 3rd Street, Suite 'DO
Louisville, KY 40202
(812) 218-7342
dstertnere3meialsales. us.com•
Autnorr:eo Signature
David Stermer
d5te,,me1#nhetalsale5.us.tom
Technical Representative
Address/Phone/Email
(s
Lam,
Quality Assurance Representative
fCnitjl�'-^GW�'®p6WLA,iry
Adtlress/Phone/Email
Category Roofing
Suocategary Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Sala Sockelingam
the Evaluation Report
Florida License
PE-62240
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Yoosef Uvi, P.E.
- Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and year (of Standard)
Equivalence of Product Standards
Certified By
sections from the Code
EL.19.�L^�'l� Cijl_CRit�{tl'Q!S{: A£P^..LCI:2:P.txii
Standard
Year
FM 4470
1992
TAS 125
2003
UL 1897
1998
UL 1897
2004
UL 580
1994
UL 580
2006
Florida Licensed Professional Engineer or Architect
Til?Si�`r_ 5Z Fsvts. T.r�°°"nt�+)`i.:^ty.:9lfi `IA-P if
https:,7www. tloridabui lding.org/pri pr_app_dti.aspx?param=wGEVXQwtDgsw8Z VNfe8A... 3122/2016
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 571' EDITION (2014)
FLORIDA PRODUCT APPROVAL
FL 14645.3-R2
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 8554300
Fax: (502)855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106 ,
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C2010-3
Date: 3.27.15
���•,,p` SOCKAt//V .
No 62240
:�. STATE OF :�41
�O,CC� �4 O R 1 O M,�
3c 2 S
FL 14645.3-R2
C2010-3
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c.
(Mnimum) in the plywood field and @ 4" o.c. at edges
New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 112:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 41.6 psf @fastener spacing f 3 . .
(Factor of Safety = 2) 74.8 ps (, astener pacing of 1 " o..
196.75 ps fastener spacing of 8" o.c�uUn
Fastener Pattem:
Type: 49-16 or 410-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends o across Panel v t
At intermediate iit 2" ac. acros panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
FL 14645.3-R2
C2010-3
3.27.15
Page 3 of 3
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests 41 & 2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc. — West Palm Beach, FL
(Formerly Hurricane Test Laboratory, LLC)
Project No. 0103-0712-09, Reporting Date 9/1/09
ANEL
EXISTING SHINGLES SEE DETAIL 2 o SEE DETAIL 7 NEW URED ON MENi FASTENER AT PANE FLAT SV-CRIMP
(REQUIRED ONLY FOR REWIRED FOR PANEL
(OPTIONAL) (PANEL OVERLAP) NEW CONSTRUCTION) ENDS ONLY.
J
NEW UNDERIAYMENT-
a1
NEW
CONSTRUCTION)
EXISTING SHINGLES
(OPTIONAL)
EXISTING UNDERLAYMENT
(OPTIONAL)
NEW UNDERLAYMENT -
(REOUIRED ONLY FOR
NEW CONSTRUCTION)
EXISTING SHINGLES
(OPTIONAL)
EXISTING UNDERLAYMENT
(OPTIONAL)
L-�
EXISTING UNDERLAYMENT
(OPTIONAL)
`MINIMUM ATTACHMENT:
Ed X 2.5' LONG BING SHANK NAIL
OR ge v 2' LONG WOOD SCREWS
SPACED 0 6' O.C. IN THE FIELD k
MIN. 2X_ W00D RAFTER/JOIST/
4' O.C. AT PLYWOOD EDGES
TRUSS AT MAX. 24- O.C.
TYPICAL PANEL
INSTALLATION CTION
#9-16 OR #10-14 WOODSCREWS
`4S7TS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
5V-CRIMP
MIN 26 GA
=am,F�
�T
DETAIL 1 19/32' THICK (MIN.)
/9-16 OR 110-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36' O.C.
DETAIL 2
5V-CRIMP
MIN 26 GA
(MIN.)
PANEL FASTENER PER
PRESSURE TABLE ON
ALLOWABLE UPLIFT PRESSURE
FASTENER
SPACING
(IN)
PRESSURE
(PSF)
36
41.6
6
48
B
196.75
GENERAL NOTES+
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLA 2. ROODPANUELS NG CODE ( SHALL BE MIN. 26 GA. (t - 0.0169'). EFFECTIVE COVERING
WIDTH OF PANEL a 24�.
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING h STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REOUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING A THE FLORIDA
BUILDING CODE. IF A DIFFERENCE. OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING @ THE CODE, THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/fRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBIURY OF OTHERS.