HomeMy WebLinkAboutNOASCANNED BY St. Lucie County MI® MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy CertainTeed Corporation 18 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roof System over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# No. 14-0224.04 and consists of pages 1 through 87. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADECOUNW c i 1 ' kdsl ,.- ryE➢ ' r E : NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 1 of 87 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Concrete Maximum Design Pressure: -542.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 39 3/S" x 65' 10' ; ASTM D 4601, Asphalt coated, fiberglass reinforced Sheet Roll weight: 701bs. Type II base sheet. (2 squares) UL Type G2 Flexiglas Base Sheet 39 3/8" x 98'9'; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet. (3 squares) UL Type G2 Flintlastic Base 20 39 3/8" x 49' 6'; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintglas Ply Sheet Type IV 39 %" x 1647% Roll ASTM D 2178, Fiberglass, asphalt impregnated ply weight: 38 lbs. Type IV sheet. (5 squares) UL Type GI Flintglas Premium Ply Sheet 39 318" x 1647% Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply Type VI weight: 40 lbs. VI sheet. (5 squares) UL Type GI Flintlastic STA 39 3/8" x 32' 10' ; ASTM D 6222, Smooth surfaced APP Modified Roll weight: 87 lbs. Grade S, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for torch application. Flintlastic GTA 39 %" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/s" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/8,' x 32' 10'; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 2 of 87 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic Premium GMS 39 3/s" x 32' 10'; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 101 lbs. Grade G, Type II Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Flintlastic FR-P 39 3/g' x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39 3/8" x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Flintlastic FR Dual Cap 39 3/s" x 32' 10'; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 Ibs. Grade G, Type I bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. Flintlastic FR Cap 30 39 3/8" x 32' 10'; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 86 tbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Flintlastic FR Cap 30 T 39 3/8" x 32' 10'; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 1001bs. Grade G, Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic Base 20 T 39 3/a" x 33'; Roll ASTM D 6163, Modified Bitumen, coated fiberglass Weight: 81 Ibs. Grade S, Type I base sheet for torch application. (1 square) Flintlastic FR Cap 30 CoolStar 39 %" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 88 tbs. Grade G, Type I Modified Bitumen membrane with (I square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic FR Cap 30 T 39 3/g" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS CoolStar weight: 1021bs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 3 of 87 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic GTA CoolStar 39 3/s" x 32' 10'; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GTA-FR CoolStar 39 3/e" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS CoolStar 39 %" x 32' 10'; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 97 lbs. Grade G, Type I Bitumen membrane with non -woven (I square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium GMS 39 3/a" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified CoolStar weight: 103 lbs. Grade G, Type II Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic FR-P CoolStar 39 3/8' x 32' 10'; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium FR-P 39 3/s" x 32' 10' ; Roll ASTM D 6164, Fire resistant, granule surfaced SBS CoolStar weight: 103 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic Ultra Poly SMS 39 3/a' x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. Grade S, Type I Bitumen Membrane with non -woven (I square) polyester mat reinforcement for mop applications. Glasbase Base Sheet 36" x 98'9' ; Roll ASTM D 4601, Asphalt coated, fiberglass base sheet. weight: 75 lbs. Type II (3 squares) UL Type G2 NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 4 of 87 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic Poly SMS Base 39 3/8" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type II base sheet. (2 squares) UL Type G2 Yosemite Venting Base Sheet 39 3/8" x 32' 10' ; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897, buffer sheet. (I square) Type II UL G3 Flintlastic APP Base T 39 3/s" x 65' 4"; Roll ASTM D6509 Modified Bitumen coated fiberglass weight: 100 lbs. base sheet. (2 squares) Flintlastic Ultra Glass SA 39 3/8" x 33' 11' ; Roll ASTM D 1970 Self -adhering, fiberglass reinforced, weight: 73 lbs. SBS modified bitumen base/ply sheet. (1 square) Black DiamondTM Base Sheet 36" x 687'; Roll ASTM D 1970 Self -adhering fiberglass reinforced weight: 78 lbs. modified bitumen base sheet (2 squares) Flintlastic SA PlyBase 39 3/s" x 64' 6"; Roll ASTM D 1970 Self -adhering, fiberglass reinforced, weight: 86 lbs. SBS modified bitumen base/ply sheet. (2 squares) F1intBond Brush 5 gallon pails ASTM D3019 Cold applied, SBS polymer modified asphalt adhesive. APPROVED INSULATIONS: Product Name FlintBoard ISO FlintBoard ISO Cold FlintBoarde ISO FlintBoardH ISO Cold ACFoam-II High Density Wood Fiberboard Perlite Insulation H-Shield H-Shield-CG DensDeck, DensDeck Prime ENRGY 3, ENRGY 3 25 PSI FescoBoard MIAMMADECOUNrY Im TABLE2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Polyisocyanurate foam insulation Expanded mineral fiber insulation Manufacturer (With Current NOA) CertainTeed Corp. CertainTeed Corp. CertainTeed Corp. CertainTeed Corp. Atlas Roofing Corporation Generic Generic Hunter Panels LLC Hunter Panels LLC Georgia Pacific Gypsum LLC Johns Manville Corp. Johns Manville Corp. NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 5 of 87 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) SECUROCK Gypsum -Fiber Roof Board Gypsum insulation USG Corp. DuraBoard Expanded mineral fiber insulation Johns Manville Corp. Structodek High Density Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard, Inc. Insulation Georgia-Pacific High Density Roof Wood fiber insulation board Georgia-Pacific Wood Products, Fiberboard LLC ISO 95+ GL Polyisocyanurate Insulation Firestone Building Products Company, LLC APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast 14 Insulation fastener for wood, various SFS Intec, Inc. steel and concrete decks 2. Dekfast 15 HS Insulation fastener for wood, various SFS Intec, Inc. steel and concrete decks 3. Dekfast DekSpike Insulation fastener for concrete various SFS Intec, Inc. decks 4. Dekfast Galvalume Steel Galvalume hex stress plate. 2 '/s" x 3 '/d' SFS Intec, Inc. Hex Plate 5. Dekfast Dekflat Round Polypropylene locking plate. 3" x 3 ''/d' SFS Inter, Inc. Lock Plate 6. OMG #14 Roofgrip Insulation fastener various OMG, Inc. 7. ASAP RoofGrip Pre- Pre -assembled Insulation various OMG, Inc. Assembled System fastener and plate 8. OMG 3 in. Round Metal Galvalume AZ50 steel plate 3" round OMG, Inc. Plates 9. Dekfast System ES #14 Pre -assembled Insulation various SFS Intec, Inc. Plastic fastener and plate 10. Trufast #14 HD Fastener Insulation fastener for wood and various Altenloh, Brinck & Co. U.S., steel decks Inc. 11. Trufast 3" Metal Insulation Galvalume AZ50 steel plate 3" round Altenloh, Brinck & Co. U.S., Plate Inc. 12. Trufast 2.4" Barbed Metal Galvalume AZ50 steel plate 2.4" round Altenloh, Brinck & Co. U.S., Seam Plates Inc. 13. FlintFast #14 Insulation and membrane Various CertainTeed Corp. fastener NOA No.: 14-0529.03 MUIMFDAD' COUNTY Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 6 of 87 APPROVED FASTENERS: TABLE3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 14. FlintFast 3" Insulation Galvalume AZ50 steel plate 3" round CertainTeed Corp. Plate 15. Trufast #15 EHD Fastener Coated carbon steel screw Various Altenloh, Brinck & Co. U.S., Inc. 16. Trufast 2" Metal Seam Galvalume steel stress plate 2" round Altenloh, Brinck & Co. U.S., Plate Inc. 17. Dekfast Galvalume Steel Steel, Galvalume AZ50 stress 3" round SFS Intec, Inc. 3" Round plate for use with all Dekfast fasteners 18. OMG 3" Galvalume Steel Galvalume coated steel plate for 3" round OMG, Inc. Plate use with approved fasteners screw. 19. 3 in. Ribbed Galvalume Round Galvalume plated steel 3" round OMG, Inc. Plate stress plate with reinforcing ribs for use with OMG fasteners. 20. AccuTrac Plate Galvalume steel plate for use 3" square OMG, Inc. with Standard Roofgrip and Standard Hex Head fasteners. 21. AccuTrac Flat Bottom A2-SS aluminized steel plate for 3" square OMG, Inc. use with #12 Roofgrip, #14 Roofgrip and #15 Roofgrip. 22. Flat Bottom Metal Plate A2-SS aluminized steel plate for 3" square OMG, Inc. use with #12, #14 or #15 Roofgrip. 23. Trufast 3" Recessed Metal Galvalume steel stress plate for 3" round Altenloh, Brinck & Co. U.S., Insulation Plate use with Trufast fasteners Inc. 24. Trufast 3" TL Insulation Galvalume steel stress plate for 3" round Altenloh, Brinck & Co. U.S., Plate use with Trufast TL fasteners Inc. 25. Dekfast Dekflat Round Polypropylene round stress plat 3" diameter SFS Intec, Inc. Plastic Lock Plate with a recessed hole for use with #12, #14 and 915 Dekfast fasteners MUIMMADE COUNTY NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 7 of 87 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 400 Ibs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 Ibs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 8 of 87 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Factory Mutual Research Corp. FM 4470 J.I.3Y8AI.AM 03/23/96 FM 4470 J.I. OD3A3.AM 04/04/97 FM 4470 J.I.2DOAO.AM 12/23/98 FM 4470 J.I. 1D7A4.AM 11/09/98 FM 4470 3023458 07/18/06 FM 4470 3024177 07/18/06 FM 4470 3031350 09/27/07 FM 4470 3046104 08/13/13 FM 4470 3039046 06/15/10 FM 4470 3048520 09/19/13 FM 4470 3024311 11/01/06 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 Momentum Technologies, Inc. ASTM D 4601 AX31G813 09/05/08 ASTM D6164 AX31G8F 06/05/09 ASTMD6222 AX31G8G 06/05/09 ASTM D 3909/ D 4897 AX31G8C 09/05/08 TrinitylERD TAS 114(J) 93504.06.01-1 06/05/O1 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 114 (H) Letter 04/05/06 TAS 114 3533.01.06 01/06/06 TAS 114 3521.07.04 07/29/04 TAS 117 (B)/ ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C10080.09.08-R4 03/25/10 ASTM 136164/134798 C31410.01.11-2 01/10/11 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM 135147/134798 C31410.10.10-R1 11/01/12 ASTM D5147/D4798 C31410.01.11-1-RI 11/01/12 ASTM D4798 C31410.01.11-2A-Rl 02/21/13 ASTM D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13-R1 12/31/13 TAS 117 B C35500.02.11 02/09/11 TAS 117 & TAS 114 C30560.03.10 03/18/10 TAS 117 & TAS 114 C30560.06.10 06/10/10 ASTMD1876 C35460.05.11 06/16/11 ASTM D1876, TAS 114 (H), C42110.08.12 08/13/12 TAS 117 (B) FM4474/TAS 114 C31420.08.10 09/21/10 NOA No.: 14-0529.03 MIAM4DAD; COUNrY Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 9 of 87 EVIDENCE SUBMITTED: Test Aaency/Identi£ter PRI Construction Materials Technologies LLC Name Report Date FM 4474/TAS 114 C37820.07.12 07/24/12 ASTM D1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 ASTM D1876, TAS 114 (H), C47320.03.14-R1 04/O1/15 FM 4474 ASTM D6163 CTC-032-02-01 01/22/08 ASTM D6163 CTC-066-02-01 08/09/11 ASTM D6222 CTC-070-02-01 08/09/11 ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-162-02-01 05/09/13 ASTM D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D6509 CTC-116-02-01 04/04/12 ASTM D1970 CTC-199-02-01 01/22/14 NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 10 of 87 Membrane Type: SBS Modified Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(4): One or more layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-II, FlintBoard ISO, H-Shield, FlintBoardn ISO Minimum 0.5" thick N/A N/A Note: Concrete deck shall be unprimed. Insulation shall be adhered with OMG OlyBond 500 Adhesive or OlyBond 500 Green in % in. ribbons spaced 12 in o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Too Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' ACFoam-III, FlintBoard ISO Cold, H-Shield CG, FlintBoarda ISO Cold Minimum 1.5" thick N/A N/A Note: Insulation shall be adhered with OMG OlyBond 500 Adhesive or OlyBond 500 Green in % in. wide beads spaced 12 in o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Maximum total insulation thickness is 12 in. Base Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet or Flintlastic Base 20 adhered using F1intBond Brush at 1.0 gal/sq. Ply Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet or (Optional) Flintlastic Base 20 adhered using FlintBond Brush at 1.0 gal/sq. Membrane: One ply of Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered using F1intBond Brush at 1.0 gal/sq. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -75 psf (With Flintlastic Base 20) (See General Limitation #9) Pressure: -82.5 psf (With any other base sheet listed) (See General Limitation #9) NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 15 of 87 CONCRETE DECK SYSTEM LIMITATIONS: If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-0529.03 Expiration Date: 05/19/18 Approval Date: 09/24/15 Page 87 of 87 TGFU.R11656 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems CERTAINTEED CORP R11656 ROOFING PRODUCTS GROUP 20 MOORES RD MALVERN, PA 19355 USA "1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or 'DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or 1/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC 'DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" are to offset a minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. 1/4-in. thick (minimum) United Sates Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible roof deck in a system with any UL Classified insulation except polystyrene." Any UL Classified insulation may be used underneath 1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC 'DensDeck® Roofboard" or 'DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or Y4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) in any existing noncombustible deck Classification. Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A, B or C roof constructions indicated below. Type G1 "Flintglas Ply Sheet" Type 4 or "Flintglas Premium Ply Sheet' Type 6 are suitable alternates for Type 15 organic felt; Type G2 "Glasbase Base Sheet' is a suitable alternate for Type 15 and Type 30 base sheets; Type G3 "Flintglas MS Cap" is a suitable alternate for Type 30 Cap Sheets. "Flex-I-Glas", "Premium Flex-I-Glas" or "Flintlastic Base 20 Sheet" is a suitable alternate for the Type G2 glass base and the Type 15 "All-Weather/Empire base sheet". Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place; ply and cap sheets are hot mopped in place. Two plies Type G1 may be utilized in place of one ply Type G2. "Flintlastic Ultra Glass SA" is a suitable alternate for Type G2 "Glasbase Base Sheet". "Black Diamond Base Sheet" is a suitable alternate for Type G2 "Glass Base Sheet". "Flintlastic SA Nailbase" or "Flintlastic SA Plybase" are suitable alternates for Type G2 base sheets in Roofing Systems (TGFU) that limit cover applications to self -adhering ply/base sheets or membranes. EPS insulation followed by'/z-in. thick cover board may be utilized in any of the following systems. The "YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible deck roof systems and, where indicated, in combustible roof deck systems. "Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA". Flintlastic APP Base T is a suitable alternate for any Type G2 base sheet. "Flintlastic Ultra Poly SMS" may be used in lieu of "Poly SMS Base" in all application Classifications. References to Type G2 base sheets includes "Channel -Vent GB". "F1intBoard Iso", "FlintBoard Iso Cold", "F1intBoard Iso-T" or "F1intBoard Iso Plus", may be used wherever polyisocyanurate insulation is specified. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. "FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate insulation is specified. "FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF" are acceptable alternatives to "FlintBoardH ISO", "FlintBoardH ISO WF" and "FlintBoardH ISO Cold", respectively, provided they do not exceed the indicated incline or thickness of the system. Any UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", "FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO DD" insulation on non-combustible decks provided a minimum 1-in. thick layer of "FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO DD" polyisocyanurate insulation is used. Max incline shall be in accordance with Classification established for the insulation/membrane roofing system, but cannot exceed 1:12. For Combustible Roof Decks - Class A: 1. A minimum 3-in. layer or a minimum two layers of 1.5-in. of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. 2. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed over a minimum 1 layer of Carlisle "FR Base Sheet 1S" or GAF "VersaShield FB-1S" over a combustible roof deck. The insulation is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. For Combustible Roof Decks - Class B: 1. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold", or a minimum 2-in. thick layer of Atlas "AC Foam III" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum thickness layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. Unless otherwise indicated the following membranes are acceptable alternates for the following membranes tabulated below, limited to 1/2-in. incline: Membrane Acceptable Alternate Flintglas MS Cap Flintglas MS Cap CoolStar Flintlastic GMS Premium Flintlastic Premium GMS CoolStar Flintlastic GTS Flintlastic GTS CoolStar Flintlastic Premium FR-P Flintlastic FR-Dual Cap, Flintlastic Premium FR-P CoolStar or Flintlastic FR-Dual Cap CoolStar Flintlastic FR Cap 30 T Flintlastic FR Cap 30 T CoolStar Flintlastic GTA Flintlastic GTA CoolStar Flintlastic GMS Flintlastic GMS CoolStar Flintlastic SA P- Cap FR Flintlastic SA Cap FR CoolStar Flintlastic GTA-FR Flintlastic GTA-FR CoolStar Flintlastic FR-P Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar Flintlastic FR-Cap 30 Flintlastic FR Cap 30 CoolStar ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT 11. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened. Base Sheet: — Type G2 "Flintlastic Base 20", mechanically fastened or adhered with hot roofing asphalt. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt.