NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy
CertainTeed Corporation
18 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roof System over Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# No. 14-0224.04 and consists of pages 1 through 87.
The submitted documentation was reviewed by Alex Tigera.
MIAMI-DADECOUNW
c i 1
' kdsl ,.- ryE➢ ' r E :
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 1 of 87
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Concrete
Maximum Design Pressure:
-542.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
All Weather/Empire Base
39 3/S" x 65' 10' ;
ASTM D 4601,
Asphalt coated, fiberglass reinforced
Sheet
Roll weight: 701bs.
Type II
base sheet.
(2 squares)
UL Type G2
Flexiglas Base Sheet
39 3/8" x 98'9'; Roll
ASTM D 4601, Type Modified Bitumen coated fiberglass
weight: 90 lbs.
II
base sheet.
(3 squares)
UL Type G2
Flintlastic Base 20
39 3/8" x 49' 6'; Roll
ASTM D 6163,
Modified Bitumen coated fiberglass
weight: 90 lbs.
Grade S, Type I
base sheet.
(1.5 squares)
Flintglas Ply Sheet Type IV
39 %" x 1647% Roll
ASTM D 2178,
Fiberglass, asphalt impregnated ply
weight: 38 lbs.
Type IV
sheet.
(5 squares)
UL Type GI
Flintglas Premium Ply Sheet
39 318" x 1647% Roll
ASTM D 2178, Type Fiberglass, asphalt impregnated ply
Type VI
weight: 40 lbs.
VI
sheet.
(5 squares)
UL Type GI
Flintlastic STA
39 3/8" x 32' 10' ;
ASTM D 6222,
Smooth surfaced APP Modified
Roll weight: 87 lbs.
Grade S, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application.
Flintlastic GTA
39 %" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application.
Flintlastic GTA-FR
39 3/s" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application.
Flintlastic GMS
39 3/8,' x 32' 10'; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 94 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application.
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 2 of 87
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic Premium GMS
39 3/s" x 32' 10'; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 101 lbs.
Grade G, Type II
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application.
Flintlastic FR-P
39 3/g' x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
39 3/8" x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap
39 3/s" x 32' 10'; Roll
ASTM D 6162,
Granule surfaced SBS modified
weight: 103 Ibs.
Grade G, Type I
bitumen membrane with a nonwoven
(1 square)
polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic FR Cap 30
39 3/8" x 32' 10'; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 86 tbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T
39 3/8" x 32' 10'; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 1001bs.
Grade G, Type I
Bitumen membrane with fiberglass
(1 square)
mat reinforcement for torch
application.
Flintlastic Base 20 T
39 3/a" x 33'; Roll
ASTM D 6163,
Modified Bitumen, coated fiberglass
Weight: 81 Ibs.
Grade S, Type I
base sheet for torch application.
(1 square)
Flintlastic FR Cap 30 CoolStar
39 %" x 32' 10"; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 88 tbs.
Grade G, Type I
Modified Bitumen membrane with
(I square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap 30 T
39 3/g" x 32' 10"; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
CoolStar
weight: 1021bs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 3 of 87
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic GTA CoolStar
39 3/s" x 32' 10'; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GTA-FR CoolStar
39 3/e" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS CoolStar
39 %" x 32' 10'; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 97 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic Premium GMS
39 3/a" x 32' 10"; Roll
ASTM D 6164,
Granule surfaced SBS Modified
CoolStar
weight: 103 lbs.
Grade G, Type II
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P CoolStar
39 3/8' x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 103 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Premium FR-P
39 3/s" x 32' 10' ; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
CoolStar
weight: 103 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Ultra Poly SMS
39 3/a' x 32' 10'; Roll
ASTM D 6164,
Smooth surfaced SBS Modified
Base Sheet
weight: 90 lbs.
Grade S, Type I
Bitumen Membrane with non -woven
(I square)
polyester mat reinforcement for mop
applications.
Glasbase Base Sheet
36" x 98'9' ; Roll
ASTM D 4601,
Asphalt coated, fiberglass base sheet.
weight: 75 lbs.
Type II
(3 squares)
UL Type G2
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 4 of 87
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic Poly SMS Base
39 3/8" x 64' 3"; Roll
ASTM D 4601,
Modified Bitumen coated polyester
Sheet
weight: 90 lbs.
Grade S, Type II
base sheet.
(2 squares)
UL Type G2
Yosemite Venting Base Sheet
39 3/8" x 32' 10' ; Roll
ASTM D 3909
Mineral Surfaced fiberglass reinforced
weight: 85 lbs.
ASTM D 4897,
buffer sheet.
(I square)
Type II
UL G3
Flintlastic APP Base T
39 3/s" x 65' 4"; Roll
ASTM D6509
Modified Bitumen coated fiberglass
weight: 100 lbs.
base sheet.
(2 squares)
Flintlastic Ultra Glass SA
39 3/8" x 33' 11' ; Roll
ASTM D 1970
Self -adhering, fiberglass reinforced,
weight: 73 lbs.
SBS modified bitumen base/ply sheet.
(1 square)
Black DiamondTM Base Sheet
36" x 687'; Roll
ASTM D 1970
Self -adhering fiberglass reinforced
weight: 78 lbs.
modified bitumen base sheet
(2 squares)
Flintlastic SA PlyBase
39 3/s" x 64' 6"; Roll
ASTM D 1970
Self -adhering, fiberglass reinforced,
weight: 86 lbs.
SBS modified bitumen base/ply sheet.
(2 squares)
F1intBond Brush
5 gallon pails
ASTM D3019
Cold applied, SBS polymer modified
asphalt adhesive.
APPROVED INSULATIONS:
Product Name
FlintBoard ISO
FlintBoard ISO Cold
FlintBoarde ISO
FlintBoardH ISO Cold
ACFoam-II
High Density Wood Fiberboard
Perlite Insulation
H-Shield
H-Shield-CG
DensDeck, DensDeck Prime
ENRGY 3, ENRGY 3 25 PSI
FescoBoard
MIAMMADECOUNrY
Im
TABLE2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Wood fiber insulation board
Perlite insulation board
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Water resistant gypsum board
Polyisocyanurate foam insulation
Expanded mineral fiber insulation
Manufacturer
(With Current NOA)
CertainTeed Corp.
CertainTeed Corp.
CertainTeed Corp.
CertainTeed Corp.
Atlas Roofing Corporation
Generic
Generic
Hunter Panels LLC
Hunter Panels LLC
Georgia Pacific Gypsum LLC
Johns Manville Corp.
Johns Manville Corp.
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 5 of 87
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description
Manufacturer
(With Current NOA)
SECUROCK Gypsum -Fiber Roof Board
Gypsum insulation
USG Corp.
DuraBoard
Expanded mineral fiber insulation
Johns Manville Corp.
Structodek High Density Fiberboard Roof Wood fiber insulation board
Blue Ridge Fiberboard, Inc.
Insulation
Georgia-Pacific High Density Roof
Wood fiber insulation board
Georgia-Pacific
Wood Products,
Fiberboard
LLC
ISO 95+ GL
Polyisocyanurate Insulation
Firestone Building Products
Company, LLC
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number Name
Description
Dimensions
(With Current NOA)
1. Dekfast 14
Insulation fastener for wood,
various
SFS Intec, Inc.
steel and concrete decks
2. Dekfast 15 HS
Insulation fastener for wood,
various
SFS Intec, Inc.
steel and concrete decks
3. Dekfast DekSpike
Insulation fastener for concrete
various
SFS Intec, Inc.
decks
4. Dekfast Galvalume Steel
Galvalume hex stress plate.
2 '/s" x 3 '/d'
SFS Intec, Inc.
Hex Plate
5. Dekfast Dekflat Round
Polypropylene locking plate.
3" x 3 ''/d'
SFS Inter, Inc.
Lock Plate
6. OMG #14 Roofgrip
Insulation fastener
various
OMG, Inc.
7. ASAP RoofGrip Pre-
Pre -assembled Insulation
various
OMG, Inc.
Assembled System
fastener and plate
8. OMG 3 in. Round Metal
Galvalume AZ50 steel plate
3" round
OMG, Inc.
Plates
9. Dekfast System ES #14
Pre -assembled Insulation
various
SFS Intec, Inc.
Plastic
fastener and plate
10. Trufast #14 HD Fastener
Insulation fastener for wood and
various
Altenloh, Brinck & Co. U.S.,
steel decks
Inc.
11. Trufast 3" Metal Insulation
Galvalume AZ50 steel plate
3" round
Altenloh, Brinck & Co. U.S.,
Plate
Inc.
12. Trufast 2.4" Barbed Metal
Galvalume AZ50 steel plate
2.4" round
Altenloh, Brinck & Co. U.S.,
Seam Plates
Inc.
13. FlintFast #14
Insulation and membrane
Various
CertainTeed Corp.
fastener
NOA No.: 14-0529.03
MUIMFDAD' COUNTY
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 6 of 87
APPROVED FASTENERS:
TABLE3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
14.
FlintFast 3" Insulation
Galvalume AZ50 steel plate
3" round
CertainTeed Corp.
Plate
15.
Trufast #15 EHD Fastener
Coated carbon steel screw
Various
Altenloh, Brinck & Co. U.S.,
Inc.
16.
Trufast 2" Metal Seam
Galvalume steel stress plate
2" round
Altenloh, Brinck & Co. U.S.,
Plate
Inc.
17.
Dekfast Galvalume Steel
Steel, Galvalume AZ50 stress
3" round
SFS Intec, Inc.
3" Round
plate for use with all Dekfast
fasteners
18.
OMG 3" Galvalume Steel
Galvalume coated steel plate for
3" round
OMG, Inc.
Plate
use with approved fasteners
screw.
19.
3 in. Ribbed Galvalume
Round Galvalume plated steel
3" round
OMG, Inc.
Plate
stress plate with reinforcing ribs
for use with OMG fasteners.
20.
AccuTrac Plate
Galvalume steel plate for use
3" square
OMG, Inc.
with Standard Roofgrip and
Standard Hex Head fasteners.
21.
AccuTrac Flat Bottom
A2-SS aluminized steel plate for
3" square
OMG, Inc.
use with #12 Roofgrip, #14
Roofgrip and #15 Roofgrip.
22.
Flat Bottom Metal Plate
A2-SS aluminized steel plate for
3" square
OMG, Inc.
use with #12, #14 or #15
Roofgrip.
23.
Trufast 3" Recessed Metal
Galvalume steel stress plate for
3" round
Altenloh, Brinck & Co. U.S.,
Insulation Plate
use with Trufast fasteners
Inc.
24.
Trufast 3" TL Insulation
Galvalume steel stress plate for
3" round
Altenloh, Brinck & Co. U.S.,
Plate
use with Trufast TL fasteners
Inc.
25.
Dekfast Dekflat Round
Polypropylene round stress plat
3" diameter
SFS Intec, Inc.
Plastic Lock Plate
with a recessed hole for use with
#12, #14 and 915 Dekfast
fasteners
MUIMMADE COUNTY
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 7 of 87
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
System Number Manufacturer Application
1. Generic Gravel applied at 400 Ibs/sq., adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
Ibs/sq.
3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 8 of 87
EVIDENCE SUBMITTED:
Test Agency/Identifier
Name
Report
Date
Factory Mutual Research Corp.
FM 4470
J.I.3Y8AI.AM
03/23/96
FM 4470
J.I. OD3A3.AM
04/04/97
FM 4470
J.I.2DOAO.AM
12/23/98
FM 4470
J.I. 1D7A4.AM
11/09/98
FM 4470
3023458
07/18/06
FM 4470
3024177
07/18/06
FM 4470
3031350
09/27/07
FM 4470
3046104
08/13/13
FM 4470
3039046
06/15/10
FM 4470
3048520
09/19/13
FM 4470
3024311
11/01/06
Underwriters Laboratories, Inc.
UL 790
R11656
01/11/13
United States Testing Company
ASTM D 5147
97457-4
06/03/88
ASTM D 5147
97-457-2R
12/02/87
Momentum Technologies, Inc.
ASTM D 4601
AX31G813
09/05/08
ASTM D6164
AX31G8F
06/05/09
ASTMD6222
AX31G8G
06/05/09
ASTM D 3909/ D 4897
AX31G8C
09/05/08
TrinitylERD
TAS 114(J)
93504.06.01-1
06/05/O1
TAS 117 (B)
3503.10.06
10/10/06
TAS 117 (B)
06490.04.07-R1
06/27/07
TAS 114 (H)
Letter
04/05/06
TAS 114
3533.01.06
01/06/06
TAS 114
3521.07.04
07/29/04
TAS 117 (B)/ ASTM D 6862
C8500SC.11.07
11/30/07
TAS 114
C8370.08.08
08/19/08
ASTM Physical Properties
C10080.09.08-R4
03/25/10
ASTM 136164/134798
C31410.01.11-2
01/10/11
ASTM D4601
C40050.09.12-1
09/28/12
ASTM D1970
C40050.09.12-2
09/28/12
ASTM 135147/134798
C31410.10.10-R1
11/01/12
ASTM D5147/D4798
C31410.01.11-1-RI
11/01/12
ASTM D4798
C31410.01.11-2A-Rl
02/21/13
ASTM D4798
C31410.12.13
12/05/13
ASTM D6222
C40050.12.13-R1
12/31/13
TAS 117 B
C35500.02.11
02/09/11
TAS 117 & TAS 114
C30560.03.10
03/18/10
TAS 117 & TAS 114
C30560.06.10
06/10/10
ASTMD1876
C35460.05.11
06/16/11
ASTM D1876, TAS 114 (H),
C42110.08.12
08/13/12
TAS 117 (B)
FM4474/TAS 114
C31420.08.10
09/21/10
NOA No.: 14-0529.03
MIAM4DAD; COUNrY
Expiration
Date: 05/19/18
Approval Date: 09/24/15
Page 9 of 87
EVIDENCE SUBMITTED:
Test Aaency/Identi£ter
PRI Construction Materials
Technologies LLC
Name
Report
Date
FM 4474/TAS 114
C37820.07.12
07/24/12
ASTM D1876, TAS 114 (H),
C45620.03.14
03/27/14
FM 4474
ASTM D1876, TAS 114 (H),
C47320.03.14-R1
04/O1/15
FM 4474
ASTM D6163
CTC-032-02-01
01/22/08
ASTM D6163
CTC-066-02-01
08/09/11
ASTM D6222
CTC-070-02-01
08/09/11
ASTM D6164/D4798
CTC-093-02-01
08/09/11
ASTM D2178
CTC-122-02-01
03/13/12
ASTM D2178
CTC-123-02-01
03/13/12
ASTM D4601
CTC-127-02-01
03/13/12
ASTM D6163
CTC-128-02-01
06/11/12
ASTM D6163
CTC-129-02-01
06/11/12
ASTM D6164
CTC-132-02-01
06/11/12
ASTM D6164
CTC-162-02-01
05/09/13
ASTM D6164
CTC-161-02-01
05/09/13
ASTM D6162
CTC-183-02-01
10/02/13
ASTM D6164
CTC-190-02-01
12/02/13
ASTM D6509
CTC-116-02-01
04/04/12
ASTM D1970
CTC-199-02-01
01/22/14
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 10 of 87
Membrane Type: SBS Modified
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(4): One or more layers of insulation adhered with approved asphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
ACFoam-II, FlintBoard ISO, H-Shield, FlintBoardn ISO
Minimum 0.5" thick N/A N/A
Note: Concrete deck shall be unprimed. Insulation shall be adhered with OMG OlyBond 500 Adhesive or
OlyBond 500 Green in % in. ribbons spaced 12 in o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Too Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
ACFoam-III, FlintBoard ISO Cold, H-Shield CG, FlintBoarda ISO Cold
Minimum 1.5" thick N/A N/A
Note: Insulation shall be adhered with OMG OlyBond 500 Adhesive or OlyBond 500 Green in % in. wide beads
spaced 12 in o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation
listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation
installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with
the polyisocyanurate side facing down. Maximum total insulation thickness is 12 in.
Base Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet or
Flintlastic Base 20 adhered using F1intBond Brush at 1.0 gal/sq.
Ply Sheet: One ply of Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet or
(Optional) Flintlastic Base 20 adhered using FlintBond Brush at 1.0 gal/sq.
Membrane: One ply of Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30 or Flintlastic FR
Cap 30 CoolStar adhered using F1intBond Brush at 1.0 gal/sq.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -75 psf (With Flintlastic Base 20) (See General Limitation #9)
Pressure: -82.5 psf (With any other base sheet listed) (See General Limitation #9)
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 15 of 87
CONCRETE DECK SYSTEM LIMITATIONS:
If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field
withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density.
All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing
Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken
from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard
RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0529.03
Expiration Date: 05/19/18
Approval Date: 09/24/15
Page 87 of 87
TGFU.R11656
Roofing Systems
Page Bottom
Roofing Systems
See General Information for Roofing Systems
CERTAINTEED CORP R11656
ROOFING PRODUCTS GROUP
20 MOORES RD
MALVERN, PA 19355 USA
"1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC
"DensDeck® Roofboard" or 'DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm
Roofboard" or 1/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board"
(Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any
existing noncombustible deck Classification. When this is done, the resulting roofing system is
acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt
joints in the gypsum board and Georgia-Pacific Gypsum LLC 'DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" are to offset a
minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it
must be placed below the overlayment board. 1/4-in. thick (minimum) United Sates Gypsum Co.
"SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass -Mat Roof Board" (Type
SGMRX) are limited to a maximum 3:12 slope when used over a combustible roof deck in a
system with any UL Classified insulation except polystyrene."
Any UL Classified insulation may be used underneath 1/2-in. thick (minimum) gypsum board or
1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC 'DensDeck® Roofboard" or 'DensDeck®
Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" or Y4-in. thick (minimum) United
States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat
Roof Board" (Type SGMRX) in any existing noncombustible deck Classification.
Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class
A, B or C roof constructions indicated below.
Type G1 "Flintglas Ply Sheet" Type 4 or "Flintglas Premium Ply Sheet' Type 6 are suitable
alternates for Type 15 organic felt; Type G2 "Glasbase Base Sheet' is a suitable alternate for
Type 15 and Type 30 base sheets; Type G3 "Flintglas MS Cap" is a suitable alternate for Type
30 Cap Sheets. "Flex-I-Glas", "Premium Flex-I-Glas" or "Flintlastic Base 20 Sheet" is a suitable
alternate for the Type G2 glass base and the Type 15 "All-Weather/Empire base sheet".
Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place; ply
and cap sheets are hot mopped in place.
Two plies Type G1 may be utilized in place of one ply Type G2.
"Flintlastic Ultra Glass SA" is a suitable alternate for Type G2 "Glasbase Base Sheet".
"Black Diamond Base Sheet" is a suitable alternate for Type G2 "Glass Base Sheet".
"Flintlastic SA Nailbase" or "Flintlastic SA Plybase" are suitable alternates for Type G2 base
sheets in Roofing Systems (TGFU) that limit cover applications to self -adhering ply/base sheets
or membranes.
EPS insulation followed by'/z-in. thick cover board may be utilized in any of the following
systems.
The "YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible
deck roof systems and, where indicated, in combustible roof deck systems.
"Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA".
Flintlastic APP Base T is a suitable alternate for any Type G2 base sheet.
"Flintlastic Ultra Poly SMS" may be used in lieu of "Poly SMS Base" in all application
Classifications.
References to Type G2 base sheets includes "Channel -Vent GB".
"F1intBoard Iso", "FlintBoard Iso Cold", "F1intBoard Iso-T" or "F1intBoard Iso Plus", may be
used wherever polyisocyanurate insulation is specified.
Uniform thickness or tapered insulation may be used in the following systems provided they do
not exceed the indicated incline or thickness.
"FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F",
"FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate
insulation is specified.
"FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF" are acceptable
alternatives to "FlintBoardH ISO", "FlintBoardH ISO WF" and "FlintBoardH ISO Cold",
respectively, provided they do not exceed the indicated incline or thickness of the system.
Any UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH
ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF",
"FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO
DD" insulation on non-combustible decks provided a minimum 1-in. thick layer of "FlintBoardH
ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH
ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or
"FlintBoardH ISO DD" polyisocyanurate insulation is used. Max incline shall be in accordance
with Classification established for the insulation/membrane roofing system, but cannot exceed
1:12.
For Combustible Roof Decks - Class A:
1. A minimum 3-in. layer or a minimum two layers of 1.5-in. of "FlintBoardH ISO Cold" or
"FlintBoardH ISO T Cold" is placed directly over a combustible roof deck and is covered with
any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a
Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or
extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum
total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be
loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor
barrier (non-UL classified) may also be used below the insulation. All insulation joints must be
staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints
directly below. The maximum incline shall be in accordance with the Classification established
for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12.
2. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed
over a minimum 1 layer of Carlisle "FR Base Sheet 1S" or GAF "VersaShield FB-1S" over a
combustible roof deck. The insulation is covered with any UL Classified roofing membrane used
in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative,
any UL Classified insulation (except expanded or extruded polystyrene), any combination, any
thickness, may be used below the 1.9-in. minimum total thickness of "FlintBoardH ISO Cold" or
"FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and
plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be
used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the
butt joints of the roof deck or from the insulation joints directly below. The maximum incline
shall be in accordance with the Classification established for the membrane/insulation roofing
assembly, however the incline cannot exceed 1/2:12.
For Combustible Roof Decks - Class B:
1. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold", or a
minimum 2-in. thick layer of Atlas "AC Foam III" is placed directly over a combustible roof
deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing
assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation
(except expanded or extruded polystyrene), any combination, any thickness, may be used below
the 1.9-in. minimum thickness layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold".
The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or
cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All
insulation joints must be staggered a minimum of 6-in. from the deck joints or from the
insulation joints directly below. The maximum incline shall be in accordance with the
Classification established for the membrane/insulation roofing assembly, however the incline
cannot exceed 1/2:12.
Unless otherwise indicated the following membranes are acceptable alternates for the following
membranes tabulated below, limited to 1/2-in. incline:
Membrane
Acceptable Alternate
Flintglas MS Cap
Flintglas MS Cap CoolStar
Flintlastic GMS
Premium
Flintlastic Premium GMS CoolStar
Flintlastic GTS
Flintlastic GTS CoolStar
Flintlastic Premium
FR-P
Flintlastic FR-Dual Cap, Flintlastic Premium FR-P CoolStar or
Flintlastic FR-Dual Cap CoolStar
Flintlastic FR Cap
30 T
Flintlastic FR Cap 30 T CoolStar
Flintlastic GTA
Flintlastic GTA CoolStar
Flintlastic GMS
Flintlastic GMS CoolStar
Flintlastic SA P-
Cap FR
Flintlastic SA Cap FR CoolStar
Flintlastic GTA-FR
Flintlastic GTA-FR CoolStar
Flintlastic FR-P
Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar
Flintlastic FR-Cap
30
Flintlastic FR Cap 30 CoolStar
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
11. Deck: NC Incline: 1/2
Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any
combination, any thickness, mechanically fastened.
Base Sheet: — Type G2 "Flintlastic Base 20", mechanically fastened or adhered with hot
roofing asphalt.
Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual
Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt.