Loading...
HomeMy WebLinkAboutPRESSURE CALCULATIONSederal g TESTING INC. 250 SW 13th Ave Poi Phone 954-784-2941 800-848-1919 Fax 954-784-7875 SCANNED DATE: 4/4/16 BY Order No.: 16-1108 CLIENT: Atlas Roofing St. Lucie County ADDRESS: 851 South Deerfield Avenue: Deerfield Beach FL 33441 PROJECT: Wynne Building Coro Flat Concrete Deck ADDRESS: 8000 South U.S. Hwy 1: Port St Lucie, FL ASCE 7-10 DESIGN PRESSURE CALL. R XR ALL PROPOSED WORK In Accordance with Chapter 30, Past®RE SUBJECT TO AW CORRECTIONS 0 REQUIRED By FIELD INSPECTORS THATI Proiect Information: Flat Concrete Deck .MAY 9fe NECESSA.t.Y IN ORDER TO. COMPLY WITH ALL APPLICABLE CODES A Height = 10' Exposure: C Ultimate Wii'fdspe&&-V; i� 170 mph - ' -- Length = 40' Category: II Basic Windspeed: Vd =132 mph Width = 28' Slope: < 7° K� = 0.85 Parapet Wall: < 3' I..v� Design Calculations: Velocity Pressure: q = 0.00256*[(0.85)(1.0)(1.0)(132)j »wit V = 37.9 psf 1►`� 11ZtJST BE KPT E p 6ii NO }:iMECTION NVML BE MADE. Width of Pressure Coefficient: 0.1(28) = 2.8' 0.4(10') = 4.0' ) use: 3'0" Effective Wind Tributary Area: <10t For parapet height 3 feet or larger, zone three (3) can be treated as zone two (2) (ASCE 7-10). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 n"n ph y Design Pressures: Zone 1 Field: Pl = 37.9*(-1.0 - 0.18) = 44.7 psf f a Zone 2 Perimeter: P2 = 37.9*(-1.8 - 0.18) = -75.1 psf Zone 3 Comers: P3 = 37.9*(-2.8 - 0.18) = -113.0 psf JOB �1N 1413W) ® MIAMF� ®i -de `+ Construction Material American Concrete Da Florida Department Enpineerinp Council Institute County of Transportation Page 2 4/4/16 Flat Concrete Deck Wynne Building Corp. 8000 S US 1 Port St Lucie, FL Attachment Requirements: Based on RAS-117 and N.O.A. 914-0529.032; fastening option with top layer of insulation minimum of/z" thick High Density Wood Fiberboard applied in hot asphalt with a maximum design pressure of -227 psf; pages 20 and 21 of 87. The system is approved with hot mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. Notes: c- Comers and perimeter area dimension shall not be less than a = 3'0" All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2014 edition. Wind load calculations based on ASCE7-10 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Sincerely, Keith LeBlanc, R& My G Federal Engineering & Testing, Inc. ,Florida Reg. No, 59394 Certificate of Authorization #5471 Miami -Dade County Certification #11-0407.01