PRODUCT SUMMARY
TAAAFF Submittal Prepared For: Date., April 24, 2015 Airstron COPY SCANNED Customer P.O. Nt b BY Customer Projectct b Sold To: St. Lucie County Job Number: Job Name: Meadowwood CC - Repl Chiller Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Air -Cooled Scroll The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Chris Cowling Trane 6965 Vista Parkway North, Suite 11 West Palm Beach, Fl- 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714 ST. LUCIE COUAR BLDG: DATE.• ELEC: DATE: PLUMB: DATE: MECH: DATE: _4- b% 1WOBSWa33515VASubmittal - Chiller- Meadowwood CC 4-24-15.doc Table Of Contents ProductSummary .......................................................................................................................... I Air -Cooled Scroll (item Al) ........................................................................................................... 3 TagData ................................................................................................................................................... 3 ProductData ............................................................................................................................................ 3 PerformanceData .................................................................................................................................... 4 Mechanical Specifications ........................................................................................................................ 5 UnitDimensions ....................................................................................................................................... 7 Weight, Clearance & Rigging Diagram ................................................................................................... 13 Accessory............................................ .................................................................................................. 16 FieldWiring ............................................................................................................................................ 20 Meadow ood CC - Rapt Chiller April 24, 2015 Tag Data - Air -Cooled Scroll l3 : 1 Item I Tag(s) Description Model Number Al 119ton PP 1 1 Air -Cooled Chiller, Scroll Compressors CGAM110A2"2AXB2A1B1A1AXXA1A1A3XXX8B XA1A3X1DiX-L-X Product Data - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP Air -Cooled Scroll Packaged Chiller 110 nominal tons 208 volt 3 phases 60 hertz High efficiency/performance Full factory refrigerant charge (HFC-410A) With freeze protection (External T-STAT control) Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2010 AHRI certified Factory installed flow switch - set point 60 cm/sec Phase reversal protection Std cooling (42 to 65F/5.5 to 18C) Grooved pipe connection Insulation high humidity/low evap temp Performance based on water High ambient (lip to 125F/up to 52C) Lanced aluminum fins Across the line starter/direct on line Single point connection main line unit power -ancillary items require other power Terminal block conn for incoming lines Enclosure type UL 1995 rated for outdoor applications Time of the day scheduling Dual high head pump Pump flow ctri by var speed drive Default A short circuit rating Elastomeric isolators With water strainer factory installed Super quiet Factory Start-up and 1st year Parts & Labor warranty Year 2-5 parts warranty whole unit FLD = Furnished by Trane U.S. Inc. l Installed by Equipment Submittal Page 3 of22 Others Meadowwood CC - Repl Chiller April 24, 2015 Performance Data - Air -Cooled Scroll Tags 110 ton PP Capacity tons 105.70 Unit power input kW 127.70 Full load efficiency EER 9.9 NPLV EER 15.1 IPLV (EER) 15.1 Sound power level (dBA) 95 Sound pressurelevel (dBA) 68 Refrigerant R410A Refrigerant charge circuit 1(lb) 91.5 Refrigerant charge circuit 2 Ib 91.5 Oil charge circuit 1 al 3.67 Oil charge circuit 2 al 3.67 Evap entering tern F 54.00" Evap leaving ternF 44.00** Evap flow rate m 252.80 Min evap flow rate m 156.50 Min flow PD eva +strainer ft H2O 7.90 Max evap flow rate m 375.70 Max flow PD eva +strainer ft H2O 44.40 Evap fluid freeze point F 32.00 Evap press drop ft H2O 12.10 Total PD eva +strainer ft H2O 16.40 Evap fouling factor hr-s ft-de F/Btu 0.00010 Saturated evap temp circuit 1 F 38.40 Saturated evap temp circuit 2 F 38.40 Ambient air temperature F 95.00** Saturated cond ternp circuit 1 F 125.30 Saturated cond ternp circuit 2 F 125.30 Compressor power input k 118.10 RLA - compressor 1A A 91.30 LRA - compressor 1A A 560.00 RLA - compressor 1 B A 109.50 LRA - compressor 1 B A 680.00 RLA - compressor 2A A 109.50 LRA - compressor 2A A 680.00 RLA - compressor 28 A 91.30 LRA - compressor 26 A 560.00 Total airflow cfm 71963 Number of fans 8 Fan motor power k 9.30 Total fan FLA A 51.80 Pump size k 7.60 Pump nominal current A 28.00 Expansion tank volume al 6.30 Avail head pressure at water connection ft H2O 71.29 Total PD um +eva +strainer ft H2O 20.50 Single point power MCA A 515.70 Single point power MOP A 600.00 Short circuit current ratio A 5000.00 Number of compressors 4 Number of circuits 2 Capacity steps 4 Shipping weight(lb) 7627.5 Operating weight (lb)8005.4 **Performance is at AHRI Conditions - 44/54 ✓3< 95 Ambient FLO = Furnished by Trans, U.S. Inc. I Installed by Equipment Submittal Page 4 of 22 Others 1 •. �. .. - � � Meadowwood CC - Rep[ Chiller April 24 2015 Mechanical Specifications - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP General ' Units are constructed of a galvanized steel frame with galvanized steel panels and access doors. Component surfaces are finished with a powder -coated paint. All paint meets the requirement for outdoor equipment of the U.S. Navy and other Federal Government Agencies. This paint finish is durable enough to withstand a 1000-consecutive-hour salt spray application in accordance with standard ASTMB117. Each unit ships with full operating charges of refrigerant and oil. Compressor and Motor The unit is equipped with four hermetic, direct -drive, 3600 rpm 60 Hz suction gas-cooled scroll compressors. The simple design has only three major moving parts and a completely enclosed compression chamber which leads to increased efficiency. Overload protection is internal to the compressors. The compressor includes: centrifugal oil pump, oil level sight glass and oil charging valve. Each compressor will have compressor heaters installed and properly sized to minimize the amount of liquid refrigerant present in the oil sump during off cycles. Unit -Mounted Starter The control panel is designed per UL 1995. The starter is in an across -the -line configuration, factory -mounted and fully pre -wired to the compressor motor and control panel. Typically, Trans scroll compressors are up to full speed in one second when started across -the -line. A factory -installed, factory -wired 820 VA control power transformer provides all unit control power (120 Vac secondary) and Trane CH530 module power (24 Vac secondary). Power line connection type is standard with a terminal block. Power Connection Power connections include main three-phase power and one separate 115V, 20 amp customer provided single phase power connection is required to power the heaters (if used for freeze protection). Short circuit current rating of 5 kA is provided. Evaporator Braze plate evaporator is made of stainless steel with copper as the braze material. It is designed to withstand a refrigerant side working pressure of 430 psig (29.6 bars) and a waterside working pressure of 150 psig (10.5 bars). Evaporator is tested at 1.1 times maximum allowable refrigerant side working pressure and 1.5 times maximum allowable water side working pressure. It has one water pass. A water strainer and a flow switch are factory installed. Immersion heaters protect the evaporator to an ambient of -20OF (-290C). All evaporators have grooved pipe connections. Note: An additional 115V, 20 amp field provided single phase power connection is required to power the heaters (if used for freeze protection). Condenser Air-cooled condenser coils have lanced aluminum fins mechanically bonded to internally -finned copper tubing. The condenser coil has an integral subcooling circuit. The maximum allowable working pressure of the condenser is 650 psig (44.8 bars). Condensers are factory proof and leak tested at 715 psig (49.3 bars). Direct -drive vertical discharge condenser fans are balanced and individually protected. Three-phase condenser fan motors with permanently lubricated ball bearings and external thermal overload protection are provided. The unit starts and operates from 32.0 F to 125.0 F. Refrigerant Circuits The unit has dual refrigerant circuits. Each refrigerant circuit has Trane scroll compressors piped in parallel with a passive oil management system. A passive oil management system maintains proper oil levels within compressors and has no moving parts. Each refrigerant circuit includes filter drier, electronic expansion valve, liquid line and discharge service valves. Capacity modulation is achieved by turning compressors on and off. The unit has four capacity stages. FLD = Furnished by Trans U.S. Inc. I Installed by Equipment submittal Page 5 of 22 Others Meadowwood CC - Repl Chiller April 24, 2015 Ugit Controls The microprocessor -based control panel is factory -installed and factory -tested. The control system is powered by a pre -wired control power transformer, and will turn on and off compressors to meet the load. Microprocessor -based chilled water reset based on return water is standard. The unit comes with a factory installed flow switch. The Trane CH530 microprocessor automatically acts to prevent unit shutdown due to abnormal operating conditions associated with low evaporator refrigerant temperature and high condensing temperature. If an abnormal operating condition continues and the protective limit is reached, the machine will shut down. The panel includes machine protection for the following conditions: low evaporator refrigerant temperature and pressure, high condenser refrigerant pressure, critical sensor or detection circuit faults, lost communication between modules, phase loss, phase reversal, over temperature protection, external and local emergency stop, and loss of evaporator water flow. When a fault is detected, the control system conducts more than 100 diagnostic checks and displays results. The display will identify the fault, indicate date, time, and operating mode at time of occurrence, and provide type of reset required and a help message. Data contained in available reports includes: water and air temperatures, refrigerant pressures and temperatures, flow switch status, EXV position, and compressor starts and run-time. All necessary settings and setpoints are programmed into the microprocessor -based controller via the operator interface. The controller is capable of receiving signals simultaneously from a variety of control sources, in any Combination, and priority order of control sources can be programmed. Communications Time of day scheduling capabilities are available for scheduling single chiller applications through Trane CH530 panel (without the need for building automation system - BAS). This feature allows the user to set up to ten events in a seven day time period. Pump Pump package includes: two pumps, expansion vessel, drainage valve, shut-off valve at entering and leaving connections. The pump package is single point power integrated into the chiller unit power with a separate factory wired control panel and separate power for freeze protection. The control of the pump is integrated into the chiller controller. The CH530 displays evaporator pump starts and run-times. Freeze protection down to an ambient of -29°C (-20°F) is included as standard. The cold parts of the pump package will be insulated. Designed with one redundant pump, it is controlled to operate both pumps through a lead/lag and failure/recovery functionality. The pump offering can be for applications that have short water loops, de -coupled systems or for applications where the integrated chiller pump could serve the entire loop volume. A variable speed drive is installed in an additional panel to control the pump. The inverter is adjusted upon start up to balance the system flow and head requirements. The purpose is to save on wasted pump energy caused by a traditional balancing valve. Isolators Molded elastomeric isolators, sized to reduce vibration transmission to the supporting structure when the unit is installed, ship with the chiller. FLD = Fumished by Trane U.S. Inc. I Installed by Equipment Submittal Page 6 of 22 Others o INLET/OUTLET WATER o CONNECTION SIZE � n BRAZE PLATE WATER VOLUMEISTORAGE 4" (100mm) 11.5 GAL (43.5 LITERS) TOP VIEW ISOMETRIC VIEW FRONT VIEW RIGHT SIDE VIEW BACK VIEW Meadowwood CC - Repl Chiller April 24 2015 Unit Dimensions - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP NO >m v Z O F U �N UrW U JV i0 EI-] Cal N \W W a ' V`! IL FLD = Furnished by Trene U.S. Inc. I Installed by Equipment Submittal Page 8 of 22 Others "NA YIAIG 01E/1 �w t 0 0 z UW th 7� Ll O O COMPRESSORS COMPRESSORS PUMP 1En S' TOP VIEW CONDENSER, CONTROL PANEL AND VSD (WHEN ORDERED) REMOVED FOR CLARITY OUTLET WATER /CONNECTION INLET WATER �CONNECTION O S m UNIT FRONT VIEW LOUVERED PANELS NOT SHOWN OVER CONTROL PANEL FOR CLARITY Meadowwood CC - Repi Chiller April 24, 2015 Unit Dimensions - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP FLD =Furnished by Trene U.S. Inc. I Installed by Equipment Submittal Page 11 pt22 Others Meadowwood CC - Repl Chiller April 24 2015 Unit Dimensions - Air -Cooled Scroll Item: A7 Qty: 1 Tag(s): 110 ton PP it Zg 0U W W _Fit 0 i ~O U_ Zz Wa LU a O Wo ll�U j R 08 FLO = Furnished by Trans U.S. Inc. I Installed by Equipment Submittal Page 12 of 22 Others UNIT CENTER OF GRAVITY LIFTING WEIGHTS W1 W2 W3 W4 SHIPPING WEIGHT 1352.71b 1458.6 lb 2273.6 lb 2451.5 lb 7627.5 Q1 FRONT VIEW CONTROL PANEL END CG OD ❑O W 1- NEAR SIDE W2-FAR SIDE 80.909 In W3 - NEAR SIDE W4-FAR SIDE SIDE VIEW C� 30 I UNIT CLEARANCE NO OBSTRUCTIONS ABOVE THE CONDENSER NO OBSTRUCTIONS RECOMMENDED. Area Required for unit operation, maintenance, and access panel. MORE CLEARANCE MAY BE NEEDED FOR AIRFLOW DEPENDING UPON THE INSTALLATION. r — — — = 39 3/8" IF 471 L _ FOR OBSTRUCTIONS OR MULTIPLE UNITS, REFER TO THE CLOSE SPACING BULLETIN. TOP VIEW 39 318" LIFTING A UNIT WITH EQUAL LENGTH STRAPS WILL NOT PRODUCE A LEVEL UNIT DURING THE LIFT BECAUSE THE CG WILL NOT BE AT THE MIDPOINT BETWEEN THE BASE LIFTING HOLES. THE FOLLOWING ADJUSTMENTS MUST BE MADE TO PRODUCE A LEVEL LIFT: - SINGLE SPREADER BAR LIFTING METHOD IF THE UNIT CG IS CLOSER TO THE CONTROL PANEL, THE STRAPS ON THE CONTROL PANEL SIDE OF THE SPREADER BAR MUST BE ADJUSTED TO BE SHORTER THAN THOSE ON THE OPPOSITE SIDE OF THE SPREADER BAR, ALLOWING THE SPREADER BAR TO MOVE TOWARD THE CONTROL PANEL AND OVER THE UNIT CG. SEVERAL ADJUSTMENTS OF THE STRAP LENGTH MAY BE REQUIRED TO PRODUCE A LEVEL UNIT DURING LIFT. - H-TYPE SPREADER BAR LIFTING METHOD IF THE STRAPS FROM THE H BAR TO THE UNIT BASE ARE THE SAME LENGTH, THE CRANE LIFTING POINT ON THE CENTER WEB OF THE H BAR MUST BE ADJUSTED TO PRODUCE A LEVEL UNIT LIFT. 0 WARNING IMPROPER LIFTING AND MOVINGI USE SPREADER BAR AS SHOWN IN DIAGRAM. REFER TO INSTALLATION MANUAL OR NAMEPLATE FOR UNIT WEIGHT. REFER TO INSTALLATION INSTRUCTIONS LOCATED INSIDE CONTROL PANEL FOR FURTHER RIGGING INFORMATION. OTHER LIFTING ARRANGEMENTS COULD RESULT IN DEATH, SERIOUS INJURY OR EQUIPMENT DAMAGE. UNIT RIGGING ISOMETRIC VIEW O O 7 s zi CUSTOMER WIRE SELECTION TABLE POWER WIRE CONNECTION TO TERMINAL BLOCK (1X1) UNIT UNIT VOLTAGE CIR1& 2(SINGLE POINT POWER) SIZE EFF LUG WIRE SIZE RANGE (PER PHASE) (1.2 MAX conductors per phase) 110 HIGH 200 4 AWG-500 MCM LEFT END VIEW 1,7 61USTABATA SHORT CIRCUIT RATING 1 ; ISOMETRIC VIEW RIGHT END VIEW Meadowwood CC - Repl Chiller April 24, 2015 Accessory - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP MOUNTING LOCATIONS 8 UNIT SIZE POINT LOAD WEIGHTS TOTAL OPERATING WEIGHT 1 2 3 4 5 6 7 8 110 1305A Ib 1732.7 133B.81b 1188.5Ib 1005.7 1 1221.11b NIA WA 8005A Ib MOUNTING HOLE DIAMETER 9116" DIMENSIONS ARE REFERENCED FROM THE END AND SIDE OF THE UNIT BASE TOP VIEW FLD = Furnished by Trane U.S. Inc. I Installed by Equipment Submittal Page 17 of 22 Others O m UNIT MOUNTING LOCATIONS AND ISOLATOR NUMBER SIZE 1 2 3 4 5 6 7 8 110 RDP4 RDP-4 RDP-4 RDP 4 RDP 4 RDP4 WA WA LIME LIME LIME LIME LIME LIME RDP-3 ISOLATORS 331 O 4 1!B' { 512' — 1/2" DIA 2 71F 9116" DIA 2 HOLES — 1/4' 12• DIA 2 3/4' 2 4 6 6 1 3 5 7 SEE ISOLATOR POINT LOADS FOR DETAILED INFORMATION ON ISOLATOR LOCATIONS. RDP-4 ISOLATORS 9/16' DIA 2 HOLES 3' 15 6' r 316" —'III{IL 3 Customer: TRANE 130 !II 120 110 �i ! L I^ I Head 100 � !1 ii I 90 HIM MMI l i;,III a 80 Z 9 r� c 60. J f ° m 50 _ Ii `f I = 40 30 i I ' 20 10 I 0 1III 0 50 100 150 SO 200 250 Flow (Usgpm) NPSH Pump sin: Power 300 350 400 Effy 80% Project: E-Curve : E-2859 70% Series: 4392 60% Size: 3x3x6 (80-150) T Impeller: 5.512 In Comments: _ 1 50% 40% Rated Conditions 30% Flow: N/A Usgpm Head: N/A it 20% Speed : 3500 rpm Motor: 10 hp 10% 0% 450 CD m aW 0 Z �n 0 O f A N O. � 0 V 9 O m CONTROLPANEL PAGE 7 OF 2 WARNING HAZARDOUS VOLTAGEI DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCKOUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STOREDVOLTAGE. UNITSWITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY. ,mu - xfiF ]BW 00MZ x6q RA 6MV WXZ MR i14 IM xxw]nxx x]W ]oHC ]�H2 Hf H2 H1 Hf H3 H1 H3AtNH4 1% IN .-P [j> A B C u u u USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO THE ABOVE COULD RESULT IN EQUIPMENT DAMAGE. 0 m a WARNING AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STOREDVOLTAGE. UNITSWITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY. USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO THE ABOVE COULD RESULT IN EQUIPMENT DAMAGE. Chiller iI(i67 Field Wiring - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): 110 ton PP 1D SINGLE SOURCE POWER IS PROVIDED AS STANDARD ON THESE PRODUCTS. FIELD CONNECTONS ARE MADE TO 1X1, OR IC2 2D FOR VOLTAGES 200V160HZ. 220W5JF .3 W60H7,4WV/60HZ, WIRE 28A SHALLBECONNECTEDTOH2. FORVOLTAGE82WV/60HZ&57SWWK7 WIRE 26A SHALL BE CONNECTTO H3. 4WW50HZ UNIT IS FACTORY WIRED WITH 26ACONNECTED TO H3-RECONNECT W IRE 26A TO H2 FOR 3WV/S0HZ.ORMFOR4ISW6)HZ. H4ISONLYAVMLABLEWIn1 4WV/50HZ PANELS. FD FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP (PTYP=NONE). THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY (PT11P--DHHP). ® CUSTOMER SUPPLED POWER 115/SOn OR 220150/1 TO POWER RELAYS. MAX FUSE SIZE IS 20 AMPS. GROUND ALL CUSTOMER SUPPLIED POWER SUPPLIES AS REQUIRED BYAPPLICABLE CODES GREEN GROUND SCREWS ARE PROVIDED IN UNIT CONTROL PANEL ID WIRED TO NEXT UNIT. 22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LFVP0014216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 45D) FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (BAS) COMMUNICATION INSTALLATION UTERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. © WIRED TO TRACER OR OTHER TRANE REMOTE DEVICE r2 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22PM14216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 45M FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (SAS) COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. WIRED TO CUSTOMER CHILLED WATER SET POINT 2-10V OR 4-21m © WIREDTO CUSTOMER EXTERNAL DEMAND UMIT 2-10V OR 420mA 9LD WIREDTOCUSTOMER2-10VOR4-2 %CAPACITY ANNUNIGATOR. 10 WIRED TO TRACER OR OTHER REMOTE DEVICE 11. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC ELECTRICAL CONNECTION INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. 4 ALL UNIT POWERWIRING MUST BE 60D VOLT COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF SO DEGREE C. REFER TO UNIT NAMEPLATE FOR MINIMUM CRCUIT AMPACITY AND MAXIMUM OVERCURRENT PROTECTION DEVICE. PROVIDE AN EQUIPMENT GROUND IN ACCORDANCE WITH APPUCABLE ELECTRIC CODES. REFER TO WIRE RANGE TABLE FOR LUG SOTS. 13, ALL FIELD WIRING MUST BE IN ACCORDANCE WNH NATIONAL ELECTRIC CODE AND LOCAL REQUIREMENTS. 14. ALLCUSTOMERCONTROLGRCUITWIRINGWWBECOPPERCONOUOTORS ONLY AND HAVEA MINIMUM INSULATION RATING OF 3M VOLTS. EXCEPT AS NOTED, ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG OR DIN RAIL MOUNTED SPRING FORCE TERMINALS. 15 UNIT PROVIDED DRY CONTACTS FOR THE CONDENSER/CHILLED WATER PUMP CONTROL RELAYS ARE RATED FOR 7.2 AMPS RESISTIVE, 2.88 AMPS PILOT DUTY,OR 4HP.72FLAAT120VOLMWHZ,CONTACTSARERATEDFOR6 AMPS GENERAL PURPOSE OLTTY 240 VOLTS 16 CUSTOMER SUPPLIED CONTACTS FOR ALL LOW VOLTAGE CONNECTIONS MUST BE COMPATABLE WITH DRY CIRCUIT 24 VOLTS DC FOR A 12 m RESISTIVE LOAD. SILVER OR GOLD PLATED CONTACTS RECOMMENDED. 17 FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP. THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY. CUSTOMER SUPPLIED POWER IISV. 6014;1PK H> CUSTOMERSUPFUED3PHASEPOWER. ff> OPTIONAL FIELD ASSIGNED PROGRAMMABLE RELAYS (STAT=PRLY). CLASS 1 FIELD WIRED MODULE. RELAY AT 120V: 7.2A RESISTIVE 288A PILOT DUTY. 12 HP7.2FLA;AT240VAC:5AMPSGENERALPURP S. 20 WIREDTO CUSTOMER CIOVDCPUMPSPEED SIGNAL 21 WHETIFACTORYMOV&IEDPUMPISNOTSELECTEOC OMERMU3 MS LYSUITABLE PUMP SY6TEM. REFERTO PUMP MANUFACTURER FOR WIRING REQUIREMEMB. ® THE CONTACTS FORAUTO STOP AND EMERGENCYSTOPSWITCHESAREJUMPERED AT THEFACTORYSYJUMPER&W2&W3TOENABLEUN90P MON.IFREMOTECONTROL IS DESIRED. REMOVED THE JUMPERS MID CONNECTTO THE DESIRED CONTROL CIRCUIT. ® IA15. LG MODULEUSED WHEN (COMM = ICI). D 1MI. BAMETINLFRFACE MODULE USED WHEN (COMM - BCNIJ FLD = Fumished by Trane U.S. Inc. I Installed by Equipment Submittal Page 22 of 22 Others n� �.4 f � �.• a �'f r • A n , ♦ A ' x � • er_ � ... .. a •�: �♦ h ..'•h r 'fit»... i1. , ., • , {Y S _ t . i,y ni n, a . R 3 r •� b s I gypp,, ty' W- �y OE a } ,