NOTICE OF ACCEPTANCE
Durapax LLC
400 Old Reading Pike, Suite 304
Pottstown, PA 19464
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
www.miamidade.gov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Durapax Coal Tar Systems over Concrete.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur, after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an.
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at 4qs1,1 e d' >pi I
This NOA renews and revises NOA No. 08-0610.03 and consists' ug 5. ,The submitted documentation was reviewed by Jorge L. Acebo. -�f
MIAMMADECOUNTY
NOA No.: 13-1022.08
Expiration Date: 01/15/19
Approval Date: 12/19/13
Page 1 of 5
ROOFING SYSTEM APPROVAL
Cateeorv:
Roofing
Sub -Category:
Built -Up Roofing
Material:
Fiberglass/Asphalt
Deck Type:
Concrete
Maximum Design Pressure:
-285 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Durapax Glass Fiber
324sq. ft.
ASTM D 4601
Asphalt coated, glass fiber mat for use as
Base Sheet
Type II
a base sheet in built-up roof systems
Durapax Organic Base
216 sq. Ft.
ASTM D 2626
Asphalt saturated and coated #43 organic
Sheet
felt base sheet for use in modified
bitumen and conventional built-up roof
systems.
Durapax TC Glass
540 sq. ft.; roll
ASTM D 4990
Glass fiber coal tar coated ply sheet for
Fiber Felt
use in conventional built-up roof systems.
Durapax Tarred Felt
432 sq. ft.; roll
ASTM D 227
Organic fiber sheet saturated with coal tar
weight: 60 lbs.
for use in coal tar built-up roof systems.
Durapax Coal Tar
ASTM D 450
Coal tar adhesive used in modified and
Roofing Pitch
Type I
conventional built-up roofing
applications.
Durapax Tar Roof
5 gallon pails
Proprietary
Refined coal tar pitch, aromatic solvents,
Resaturant
non -asbestos fibers and fillers, and wet
adhesion surfactants designed to
rejuvenate coal tar pitch roofing systems.
APPROVED INSULATIONS:
Product Name
TABLE 2
Product Description Manufacturer
(With Current NOA)
ENRGY 3 Polyisocyanurate foam insulation Johns Manville
Georgia-Pacific High Density Roof Wood fiber insulation board Georgia-Pacific Wood
Fiberboard Products, LLC
APPROVED FASTENERS: I L
TABLE 3 F
Fastener Manufacturer
Number Product Descriptions Dimensions (With current NOA)
1. N/A N/A N/A N/A
NOA No.: 13-1022.08
MIAMMMECOUNTY Expiration Date: 01/15/19
Approval Date: 12/19/13
Page 2 of 5
EVIDENCE SUBMITTED:
Test Agency
Factory Mutual Research Corporation
Atlantic and Caribbean Roofing Consulting LLC
PRI Construction Materials Technologies LLC
Test Identifier
Description
Date
3029063
Class 4470
5/22/07
ACRC 07-067
TAS-114-D
11/12/07
DRPX-001-02-01REV
ASTM D 450
9/25/08
DRPX-002-02-OIREV
ASTM D 4990
9/25/08
DRPX-003-02-OIREV
ASTM D 227
9/25/08
DRPX-004-02-OIREV
ASTM D 4601
9/25/08
DRPX-006-02-OIREV
ASTM D 2626
11/07/08
NOA No.: 13-1022.08
Expiration Date: O1/15/19
Approval Date: 12/19/13
Page 3 of 5
APPROVED ASSEMBLIES:
Deck Type 4I: Concrete, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A: All layers of insulation adhered with approved asphalt or coal tar pitch to primed
deck. Roof membranes are subsequently fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/fe
ENRGY 3
Minimum 1.5" thick N/A
N/A
One or more layers of any of the following insulations:
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft2
Georgia-Pacific High Density Roof Fiberboard
Minimum I/z" thick N/A
N/A
Concrete deck shall be primed with ASTM.D 41 asphalt primer and allowed to dry prior to
application of base insulation. All insulation shall be adhered in full mopping of approved hot
asphalt or coal tar pitch within the EVT range and at a rate of 20-40 Ibs/100 fe. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer
only shall be used only as base layers with a second layer of approved top layer insulation installed
as the final membrane substrate. Composite insulation panels may be used as a top layer placed
with the polyisocyanurate side facing down.
14* Base Sheet:
Durapax Organic Base Sheet or Durapax Glass Fiber Base Sheet in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
�
lbs./sq.
8Ply Sheet:
Two or more plies of Durapax Tarred Felt, Durapax TC Glass Fiber felt or
Durapax TC Premium Glass Fiber Felt adhered in a full mopping of hot Durapax
Coal Tar Roofing Pitch applied at not less than 20 lbs./sq.
Cap Sheet:
None
Surfacing:
Flood Coat of hot Durapax Coal Tar Roofing Pitch at an application rate of 70
lbs./sq.; plus gravel or slag at application rates of 400 and 300 lbs./ sq.,
respectively, in accordance with ASTM DI863. Or any other Miami Dade
approved coating options.
Maximum Design
Pressure:
-285 psf; (See General Limitation #9.)
� F�y
FILE "
NOA No.: 13-1022.08
Expiration Date: 01/15/19
Approval Date: 12/19/13
Page 4 of 5
CONCRETE SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field
withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density.
All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing
Application Standard RAS 117, calculations shall be signed and sealed by a Florida Registered Engineer,
Architect, or Registered Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener
spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not be
applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform
with Roofing Application Standard RAS 1 I 1 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended comers and comers).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not be
applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with t 111a ldi e
Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE