Loading...
HomeMy WebLinkAboutPRODUCT SUMMARYPrepared For: St Lucie County Sold To: Submittal Date: January 14, 2016 Customer P.O. Number. Customer Project Number: Job Number: Job Name: SLC - Ag Center Repl Chiller Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Air -Cooled Scroll Chris Cowling Trane 6965 Vista Parkway North, Suite 11 West Palm Beach, FL 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714 SCANNED BY SL Lucie County The attached information describes the equipment we propose furnish for this project, and is submitted for your approval. ST LUCIE COUM PLAN REVIEW BLDG• DATE EL: DATE: PLUMB: DATE: MECH.- DATE: S e/e/ J:IJOBS146144127121Submittal - SLC Ag Center Chiller Repl 1-13-16.doc Table Of Contents ProductSummary ...........................................................................................................................1 Air -Cooled Scroll (Item Al) ............................................................................................................3 TagData..................................................................................................................................................3 ProductData ................................................ :................................ .............................. ............................. 3 PerformanceData.................................................................................................................................... 4 Product Data Report-CGAM040............................................................................................................... 5 MechanicalSpecifications........................................................................................................................ 7 UnitDimensions....................................................................................................................................... 9 Weight, Clearance & Rigging Diagram................................................................................................... 15 Accessory.............................................................................................................................................. 18 FieldWiring............................................................................................................................................ 21 SLC -Ag Center. Rep[ Chiller January 14, 2016 Tag Data - Air -Cooled Scroll Q : 1 Item I Tag(s)I MY I Description Model Number Al CGAM040 1 Air -Cooled Chiller, Scroll Compressors CGAM040A2"2AXB2AlBlAlDXXAlAlA4BXAXX XA1A3A1D1X-L-X Product Data - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM040 Air -Cooled Scroll Packaged Chiller 40 nominal tons 208 volt 3 phases 60 hertz High efficiency/performance Full factory refrigerant charge (HFC-410A) With freeze protection (External T-STAT control) Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1, AHRI certified Factory installed flow switch - set point 60 cm/sec Sid cooling (42 to 651715.5 to 18C) Grooved pipe connection Insulation high humidity/low evap temp (thicker insulation option) Lanced aluminum fins with Factory CompleteCoat coating Across the line starter/direct on line Single point connection main line unit power -ancillary items require other power Terminal block conn for incoming lines (Field supplied & installed Disconnect by Others) Enclosure type UL 1995 rated for outdoor applications BACnet interface External chilled/hot water and demand limit setpnt - 2-10Vdc Programmable relays Elastomeric isolators (FId) With water strainer factory installed Architectural louvered panels / hail guards Factory Start-up AND 15r year Parts & Labor warranty 2nd-5th year Full Parts Warranty —whole unit 6t'-101h year Compressor Parts Warranty Excludes: Installation, Factory Disconnect, Coatings of any kind, Equipment Storage, Extended warranty other than those listed, Anything not listed above. FLD= Furnished by Trane U.S. Inc./Instaltedby Equipment Submittal Page 3of 23 Others SLC -Ag Center.Repl Chiller - January 14 2016 Performance Data - Air -Cooled Scroll Tags CGAM040 Capacity tons 37.90 Unit power input k 45.70 Full load efficiency EER 9.9 NPLV EER 13.6 IPLV (EER) 13.6 Sound power level (dBA) 89 Sound pressure level (dBA) 63 Refrigerant R410A Refrigerant charge circuit 1 Ib 32.0 Refrigerant charge circuit 2 Ib 32.0 Oil charge circuit 1 al 1.74 Oil charge circuit 2 al 1.74 Evap entering temp F 54.00 Evap leaving temp F 44.00. Evap flow rate m 90.60 Min evap flow rate m 56.70- Min flow PD eva +strainer ft H2O 8.00 Max evap flow rate m -136.10 Max flow PD eva +strainer ft H2O 43.00 Evap fluid freeze point F 32.00 Evap press drop ft H2O 17.40 Total PD eva +strainer ft H2O 19.60 Evap fouling factor hr-s ft-de F/Btu 0.00010 Saturated evap temp circuit 1 F 35.60 Saturated evap temp circuit 2 F 35.60 Ambient air temperature F 95.00 Saturated cond temp circuit 1 F 119.80 Saturated cond terncircuit 2 F 119.70 Compressor power input k 40.60 RLA - compressor 1A A 39.10 LRA - compressor 1A A 267.00 RLA - compressor 1 B A 39.10 LRA - compressor 1 B A 267.00 RLA - compressor 2A A 39.10 LRA - compressor 2A A 267.00 RLA - compressor 26 A 39.10 LRA - compressor 2B A 267.00 Total airflow cfm 37202 Fan motor power kW 4.60 Total fan FLA A 2.20 Single point power MCA A 197.30 Single point power MOP A 225.00 Short circuit current ratio A 5000.00 Number of compressors 4 Number of circuits 2 - Capacity steps 4. Shipping weight (Ib 3666.3 Operating weight(lb) 3697.5 Length in 113.800 Width in 88.400 Heightin 84.800 FLO = Fumished by Trane U.S. Inc. /Installed by Equipment Submittal Page 4 of 23 Others ' SLC - Ag Center.Repl Chiller January 14 2016 Job Information ®r EAIir-Cooled Chiller, Scroll Compressors Tag CGAM040 Model Number CGAM 40 Quantity 1 Product Version 183 Unit nominal tonnage 40 tons Unit type High efficiency General Information Sound attenuator package Super quiet IPLV 13.6 EER Refrigerant R410A NPLV 13.6 EER Capacity 37.90 tons Sound power level 89 dBA Full load efficiency 9.9 EER Sound pressure level • 63 dBA Note: ' At 30 feet in free field. Evaporator Information Evaporator application Slid cooling Fouling factor 0.00010 hr-sq ftdeg FBtu Entering temperature 54.00 F Saturated temperature-ckt 1 35.60 F Leaving temperature 44.00 F Saturated temperatureckt 2 35.60 F Fluid flow rate 90.60 gpm Minimum flow rate 56.70 gpm Pressure drop 17.40 ft H2O Pressure drop at min flow rate 8.00 ft H2O Total PD evap+strainer 19.60 ft H2O Maximum flow rate 136.10 gpm Evap fluid type Water Pressure drop at max flow rate 43.00 ft H2O Evap fluid freeze point 32.00 F Freeze protection facto inst Ext. tstat control Condenser Information Unit application High ambient Total fan FLA 2.20 A Ambient air temperature 95.00 F Total airflow 37202 cfm Elevation 0.00 ft Fin material Complete cat Number of fans 0.00 Each Saturated temperatureckt 1 119.80 F Fan motor power 4.60 kW Saturated temperatureckt 2 119.70 F Compressor Information Number of compressors 4 RLA LRA Number of circuits 2 Compressor 39.10A 267.00A Capacity steps 4 Compressor B 39.10 A 267.00 A Total compressor power 40.60 kW Compressor D 39.10 A 267.00 A Compressor E 39.10 A 267.00 A Electrical Information Unit voltage 208 volt 3 phases MCA MOP Unit hertz 60 hertz Single point power 197.30 A 225.00 A Short circuit Default Incoming power line connection Single point Short circuit rating 5000.00 A Starter type Across the line Unit power 45.70 kW Note: Unit power Includes: compressom, condenser fans, and control kW Certified In accordance with the AHRI Alr-Cooled Water -Chilling and Heat Pump Water -Heating Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 6501590 (I-P) and AHRI Standard 5511591 (S0. Certified units may be found in the AHRI Directory at w .anddlrectory.org. 111412016 Product Version 183 Pace 1 of FLO = Furnished by Trane U.S. Inc. / Installed by - Equipment Submittal Page 5 of 23 Others SLC - Ag Center Rapt Chiller _ January 14, 2016 Alf -Cooled Chiller, Scroll upiTipressqrs Job Information 7F Tag CGAM040 Model Number CGAM 40 Quantity 1t:- t Product Version 183 Unit nominal tonnage 40 tons -- Unit type High efficiency Physical Information Length 113.800 in Water connections 3.000In Width 88.400 in Refrigerant charge circuit 1 32.0 lb Height 84.800 in Refrigerant charge circuit 2 32.0 lb Operating weight 3697.51b Oil charge circuit 1 1.74 gal Shipping weight 3666.31b Oil charge circuit 2 1.74 gal nTCrTla9On Tor L=U hTCjecis ASHRAE 90.113SA compliance ASHRAE all to 2010 IPLV 13.6 EER Refrigerant charge circuit 1 32.0 lb Rated capacity (AHRI) 37.90 tons Refrigerant charge circuit 2 32.0 lb - Note: This product meets the minimum efficiency requirements of ASHRAE Standard 90.1 and CANSICSA.C743 for all versions (which are based on AHRI standard rating conditions) and, therefore, also meets the LEED "Minimum Energy Perfornancee prerequisite in the Energy and Atmosphere section. The LEED Green Building Rating System TM. developed by the U.S. Green Building Council, provides independent, third -party verification that a building project meets green 111412016 ProductVersion 183 Paae 2 of 2 FLD = Furnished by Trans U.S. Inc. /Installed by Equipment Submittal Page 6 of 23 Others SLC -Ag Center Rapt Chiller January 14, 2016 Mechanical Specifications - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM040 General Units are constructed of a galvanized steel frame with galvanized steel panels and access doors. Component surfaces are finished with a powder -coated paint. All paint meets the requirement for outdoor equipment of the U.S. Navy and other Federal Government Agencies. This paint finish is durable enough to withstand a 1000-consecutive-hour salt spray application in accordance with standard ASTMB117. Each unit ships with full operating charges of refrigerant and oil. Compressor and Motor The unit is equipped with four hermetic, direct -drive, 3600 rpm 60 Hz suction gas-cooled scroll compressors. The simple design has only three major moving parts and a completely enclosed compression chamber which leads to increased efficiency. Overload protection is internal to the compressors. The compressor includes: centrifugal oil pump, oil level sight glass and oil charging valve. Each compressor will have compressor heaters installed and properly sized to minimize the amount of liquid refrigerant present in the oil sump during off cycles. Unit -Mounted Starter The control panel is designed per UL 1995. The starter is in an across -the -line configuration, factory -mounted and fully pre -wired to the compressor motor and control panel. Typically, Trane scroll compressors are up to full speed in one second when started across -the -line. A factory -installed, factory -wired 820 VA control power transformer provides all unit control power (120 Vac secondary) and Trane CH530 module power (24 Vac secondary). Power line connection type is standard with a terminal block. Power Connection Power connections include main three-phase power and two separate 115V, 20 amp customer provided single phase power connections are required to power the heaters (if used for freeze protection) as well as the programmable relays. Short circuit current rating of 5 kA is provided. Evaporator Braze plate evaporator is made of stainless steel with copper as the braze material. It is designed to withstand a refrigerant side working pressure of 430 psig (29.6 bars) and a waterside working pressure of 150 psig (10.5 bars). Evaporator is tested at 1.1 times maximum allowable refrigerant side working pressure and 1.5 times maximum allowable water side working pressure. It has one water pass. A water strainer and a flow switch are factory installed. Immersion heaters protect the evaporator to an ambient of -20OF (-290C). All evaporators have grooved pipe connections. Note: An additional 115V, 20 amp field provided single phase power connection is required to power the heaters (if used for freeze protection). Condenser Air-cooled condenser coils have aluminum fins mechanically bonded to internally -finned copper tubes. Completely assembled coils are then dipped and baked in an electro-mechanically bonded flexible epoxy coating. Coating covers all condenser coil surfaces with uniform coating to protect against corrosion with negligible performance loss. Coil with coating successfully passed 5,000 hour salt spray test. The condenser coil has an integral subcooling circuit. The maximum allowable working pressure of the condenser is 650 psig (44.8 bars). Condensers are factory proof and leak tested at 715 psig (49.3 bars). Direct -drive vertical discharge condenser fans are balanced and individually protected. Three-phase condenser fan motors with permanently lubricated ball bearings and external thermal overload protection are provided. The unit starts and operates from 32.0 F to 125.0 F. Refrigerant Circuits The unit has dual refrigerant circuits. Each refrigerant circuit has Trane scroll compressors piped in parallel with a FLD= Furnished by Trane U.S. Inc./instaliedby Equipment Submittal Page 7 of 23 Others SLC -Ag Center Repl Chiller January 14 2016 passive oil management system. A passive oil management system maintains proper oil levels within compressors and has no moving parts. Each refrigerant circuit includes filter drier, electronic expansion valve, liquid line and discharge service valves. Capacity modulation is achieved by turning compressors on and off. The unit has four capacity stages. Unit Controls The microprocessor -based control panel is factory -installed and factory -tested. The control system is powered by a pre -wired control power transformer, and will turn on and off compressors to meet the load. Microprocessor -based chilled water reset based on return water is standard. The unit comes with a factory installed flow switch. The Trane CH530 microprocessor automatically acts to prevent unit shutdown due to abnormal operating conditions associated with low evaporator refrigerant temperature and high condensing temperature. If an abnormal operating condition continues and the protective limit is reached, the machine will shut down. The panel includes machine protection for the following conditions: low evaporator refrigerant temperature and pressure, high condenser refrigerant pressure, critical sensor or detection circuit faults, lost communication between modules, phase loss, phase reversal, over temperature protection, external and local emergency stop, and loss of evaporator water flow. When a fault is detected, the control system conducts more than 100 diagnostic checks and displays results. The display will identify the fault, indicate date, time, and operating mode at time of occurrence, and provide type of reset required and a help message. Data contained in available reports includes: water and air temperatures, refrigerant pressures and temperatures, flow switch status, EXV position, and compressor starts and run-time. All necessary settings and setpoints are programmed into the microprocessor -based controller via the operator interface. The controller is capable of receiving signals simultaneously from a variety of control sources, in any combination, and priority order of control sources can be programmed. Communications BACNet Interface allows the user to easily interface using BACNet MS/TP via a single twisted -pair wiring to a factory -installed and tested communication board. External Chilled Water and Demand Limit Setpoint Controls, sensors, and safeties allow reset of chilled water temperature, based on temperature signal, during periods of low outdoor air temperature (chilled water reset based on return chilled water temperature is standard). The demand limit setpoint is communicated to a factory -installed and tested communication board through a 2-10 Vdc or 4-20 MA signal. Programmable Relays Predefined, factory -installed, programmable relays allow the user to select four relay outputs. Available outputs are: Alarm -Latching, Alarm -Auto Reset, General Alarm, Warning, Chiller Limit Mode, Compressor Running, and Tracer Control. Note: An additional 115V, 20 amp field provided power connection is required to power the programmable relays. Architectural Louvered Panels Louvered panels cover the complete condensing coil and service area beneath the condenser. Isolators Molded elastomeric isolators, sized to reduce vibration transmission to the supporting structure when the unit is installed, ship with the chiller. FLD = Furnished by Trans U.S. Inc. /Installed by Equipment Submittal Page 8 of 23 Others INLET/OUTLET WATER p CONNECTION SIZE BRAZE PLATE WATER VOLUME/STORAGE Ills 3" (80mm) 2.4 GAL (9.1 LITERS) TOP VIEW ISOMETRIC VIEW FRONT VIEW RIGHT SIDE VIEW BACK VIEW SLC - Ag Center Repl Chiller January 14 2016 Unit Dimensions - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM040 FLO = Fumished by Trane U.S. Inc. /Installed by Equipment Submittal Page 10 of 23 Others SLC- M Center Rep[ Chiller January 14 2016 Unit Dimensions - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM040 i a! 3 U 0 QLU J ; W M Q LU o. W J � W Z tY W OW C,fO wz mw zx w2 ❑— Z❑ O� FLO= Furnished by Thane U.S. Inc./Installedby Equipment Submittal Page if of23 Others SLC -Ag Center Repl Chiller January 14 2016 Unit Dimensions - Air -Cooled Scroll Item: Al My: 1 Tag(s): CGAM040 LU H Z O of Lt- FLO = Fumished by Trene U.S. Inc. /Installed by Equipment Submittal Page 12 of 23 Others SLC - Ag Center Rep] Chiller January 14 2016 Unit Dimensions - Air -Cooled Scroll Item: Al My: 1 Tag(s): CGAM040 O FLD= Fumishedby Tirane U.S. Inc. llnstalledby Equipment Submittal Page 13 of 23 Others SLC - Ag Center Repl Chiller January14 2016 Unit Dimensions - Air -Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM040 LU U F- H W 2 O U FLD = Furnished by Tmne U.S. Inc. /Installed by Equipment Submittal Page 14 of 23 Others UNIT CENTER OF GRAVITY LIFTING WEIGHTS SHIPPING W1 N/2 W3 W4 WEIGHT 3666.3 lb 1113.7m 1133.1 lb 660.0lb 671AIb FRONT VIEW CONTROLPANELEND SIDE VIEW 0 y UNIT CLEARANCE THE CONDENSER anu ELECTRIC CODE ARTICLE 110MORE access panel. MORE CLEARANCE MAY BE NEEDED FOR AIRFLOW DEPENDING UPON THE INSTALLATION. FOR OBSTRUCTIONS OR MULTIPLE UNITS, REFER TO THE CLOSE SPACING BULLETIN. TOP VIEW 3 D A LIFTING A UNIT WITH EQUAL LENGTH STRAPS WILL NOT PRODUCE A LEVEL UNIT DURING THE LIFT BECAUSE THE CG WILL NOT BE AT THE MIDPOINT BETWEEN THE BASE LIFTING HOLES. THE FOLLOWING ADJUSTMENTS MUST BE MADE TO PRODUCE A LEVEL LIFT: - SINGLE SPREADER BAR LIFTING METHOD IF THE UNIT CG IS CLOSER TO THE CONTROL PANEL, THE STRAPS ON THE CONTROL PANEL SIDE OF THE SPREADER BAR MUST BE ADJUSTED TO BE SHORTER THAN THOSE ON THE OPPOSITE SIDE OF THE SPREADER BAR, ALLOWING THE SPREADER BAR TO MOVE TOWARD THE CONTROL PANEL AND OVER THE UNIT CG. SEVERAL ADJUSTMENTS OF THE STRAP LENGTH MAY BE REQUIRED TO PRODUCE A LEVEL UNIT DURING LIFT. - H-TYPE SPREADER BAR LIFTING METHOD IF THE STRAPS FROM THE H BAR TO THE UNIT BASEARE THE SAME LENGTH, THE CRANE LIFTING POINT ON THE CENTER WEB OF THE H BAR MUST BE ADJUSTED TO PRODUCE A LEVEL UNIT LIFT. 0 WARNING IMPROPER LIFTING AND MOVING! USE SPREADER BAR AS SHOWN IN DIAGRAM. REFER TO INSTALLATION MANUAL OR NAMEPLATE FOR UNIT WEIGHT. REFER TO INSTALLATION INSTRUCTIONS LOCATED INSIDE CONTROL PANEL FOR FURTHER RIGGING INFORMATION. OTHER LIFTING ARRANGEMENTS COULD RESULT IN DEATH, SERIOUS INJURY OR EQUIPMENT DAMAGE. UNIT RIGGING ISOMETRIC VIEW CUSTOMER WIRE SELECTION TABLE POWER WIRE CONNECTION TO TERMINAL BLOCK 0X1) UNIT UNIT CIR I& 2(SINGLE POINT POWER) SIZE EFF VOLTAGE LUG WIRE SIZE RANGE (PER PHASE) 040 HIGH 2W (1 MAXconducter per phase) 4 AWG-500 MCM 32 6" 00 75 In' FRONT VIEW BOTTOM VIEW SHORT CIRCUIT RATING I sw. ISOMETRIC VIEW TION SLC • Ag Center Rep[ Chiller January 14 2016 Accessory - Air -Cooled Scroll Item: Al City: 1 Tag(s): CGAM040 MOUNTING LOCATIONS & UNIT POINT LOAD WEIGHTS TOTALOPERATING SIZE WEIGHT 1 1 2 3 4 1 5 6 040 1151.3ID 1036.216 610S 10 811.2 ID I N/A N/A 3697.51b MOUNTING HOLE DIAMETER 9/16" DIMENSIONS ARE REFERENCED FROM THE END AND SIDE OF THE UNIT BASE TOP VIEW FLO = Fumished by Trans U.S. Inc. /Installed by Equipment Submittal Page 19 of 23 Others UNIT MOUNTING LOCATIONS AND ISOLATOR NUMBER SIZE 1 2 3 4 6 6 pop RDP-0 RDP-0 ROP4 RDP4 MA MA BRICK RED BRICKRED BRICK RED BRICK RED I RDP-3 ISOLATORS 1/2" DIA 2 7/� J 2 1/2" 9116" DIA 2 HOLES 11181, 77 L F114" T 3 SEE ISOLATOR POINT LOADS FOR DETAILED INFORMATION ON ISOLATOR LOCATIONS. RDP-4 ISOLATORS 9/16"DIA 2 HOLES /2" DIA 3" 2 3/3 3/8" T CONTROLPANEL PAGE OF r." WARNING HAZARDOUS VOLTAGE DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCKOUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STOREDVOLTAGE. UNITSWITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY. w:E,s I YqV� UNRI9 FRCfOpYyyfPrrERR�6N0.Yly r1 Emxx�w�a'nloaxwllUlB Mi OR IM }{U SVVHi6 �H2 aA SPV®6 3BA EE 'NO H1 aww� �� �H2 H1 H2 HI H1 H]]fw� a IKET-M [D A B u Lf USE COPPER CONDUCTORS ONLY) UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO THE ABOVE COULD RESULT IN EQUIPMENT DAMAGE. CONTROLPANEL PAGE20F2 ID WARNING HAZARDOUS VOLTAGEI AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE TRATALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE. REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DD THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY. USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO 00 THE ABOVE COULD RESULT IN EQUIPMENT DAMAGE. TY Hf N`=' SLC - Ao Center Reol Chiller January 14.2016 Field Wiring - Air -Cooled Scroll Item: Al My: 1 Tag(s): CGAM040 1D SINGLE SOURCE POWER IS PROM DED AS STANDARD ON THESE PRODUCTS, FIELD CONNECTIONS ARE MADE TO 1X1, OR 102. FOR VOLTAGES 20W/6011Z, 220V/50HZ, 38W/WHZ 460V/60HZ, WIRE 26A SHALL BE CONNECTED TO H2. FOR VOLTAGES 23WXOHZ&575V/60HZ, WIRE 26A SHALL SE CONNECT TO H3. 400VI50HZ UNIT IS FACTORY WIRED WITH 26A CONNECTED TO H3 - RECONNECT WIRE 26A TO H2 FOR 380VI50HZ,ORH4FOR415V/SDHZ. WISONLYAVAILASLEWITH 400VISONZ PANELS. FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP (PTYP=NONE). THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY (PTYP=DHHP). ® CUSTOMER SUPPLIED POWER 115/6011 OR 22N50I1 TO POWER RELAYS. MAX. FUSE SIZE IS 20 AMPS. GROUND ALL CUSTOMER SUPPLIED POWER SUPPLIES AS REQUIRED BY APPLICABLE CODES. GREEN GROUND SCREWS ARE PROVIDED IN UNIT CONTROL PANEL 5� WIRED TO NEXT UNIT. u AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22PW14216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (BAS) COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. © WIRED TO TRACER OR OTHER TRANE REMOTE DEVICE. 22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22P0014216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (BAS) COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. ]� WIRED TO CUSTOMER CHILLED WATER SET POINT 2-1W OR 4-20m 6D WIRED TO CUSTOMER EXTERNAL DEMAND LIMIT 240V OR 42Om WIRED TO CUSTOMER 2-10V OR 42Om %CAPACITY ANNUNICIATOR. 10 WIRED TO TRACER OR OTHER REMOTE DEVICE. 11. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC ELECTRICAL CONNECTION INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. 12 ALL UNIT POWER WIRING MUST BE 6W VOLT COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF 90 DEGREE C. REFER TO UNIT NAMEPLATE FOR MINIMUM CIRCUIT AMPACITY AND MAXIMUM OVERCURRENT PROTECTION DEVICE. PROVIDE AN EQUIPMENT GROUND IN ACCORDANCE WITH APPLICABLE ELECTRIC CODES. REFER TO WIRE RANGE TABLE FOR LUG SIZES. 11 ALL FIELD WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND LOCAL REQUIREMENTS. 14. ALL CUSTOMER CONTROL CIRCUIT WRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM INSULATION RATING OF WO VOLTS. EXCEPT AS NOTED, ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG OR DIN RAIL MOUNTED SPRING FORCE TERMINALS. 15 UNIT PROVIDED DRY CONTACTS FOR THE CONDENSER/CHILLED WATER PUMP CONTROL RELAYS ARE RATED FOR 7.2 AMPS RESISTIVE, 2.88 AMPS PILOT DUTY, OR j HP, T2 FLAAT 120 VOLTS 60 HZ, CONTACTS ARE RATED FOR 5 AMPS GENERAL PURPOSE DUTY 240 VOLTS. 18 CUSTOMER SUPPLIED CONTACTS FOR ALL LOW VOLTAGE CONNECTIONS MUST BE COMPATABLE WITH DRY CIRCUIT 24 VOLTS DC FOR A 12 mA RESISTIVE LOAD. SILVER OR GOLD PLATED CONTACTS RECOMMENDED. 1T FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP. THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY. CUSTOMER SUPPLIED POWER 115V, 601-1; 1PH. 10 CUSTOMER SUPPLIED 3 PHASE POWER. 18 OPTIONAL FI ELD ASSIGNED PROGRAMMABLE RELAYS(STAT=PRLY). CLASS 1 FIELD WIRED MODULE, RELAY AT 120V: 7.2A RESISTIVE 21BA PILOT DUTY, 12 HPT.2FLA; AT240VAC: 5 AMPS GENERAL PURPOSE. E0> WIRED TO CUSTOMER O-10 VDC PUMP SPEED SIGNAL. 21 > WHENFACTORYPRONDED PUMPISNOTSEUECTED. CUSTOMERMUSTSUPPLYSUITABUE PU IP SYSTEM. REPERTD PMP MANUFACTURER FOR WIRING REQUIREMENTS. ME CONTACTS FORAUTO STOPANOEMERGENCY STOP SWITCHES AREJLMPEREDAT THE FACTCWW JUMPERS W2 &MM ENABLE UMTOPEMnON.IF REMOTE CONTROL IS DESI RED, RDAOV EDTHEJUMPER8MDOOMECTWTHE DESIRED CONTROL a RCUR. 23 1AMM MODULE USED WHEN (COMM - LC6. 24 1M1, BACNETINTERFACE MOWLE f6E0 WHEN (COMM= BCNn. FLD = Furnished by Tmne U.S. Inc. /Installed by Equipment Submittal Page 23 of 23 Others