NOTICE OF ACCEPTANCE
Gaeo Western LLC
1245 Chapman drive
Waukesha, WI 5318f
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
w .miamidade.eov/oera
SCANNED
BY
St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA
- Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the A14J may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it
is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:: GACO WESTERN ROOF COATING SYSTEMS
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 09-1109.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Jorge L. Acebo.
MAMMADE COUNTY
,...• 1
fOt No.:12-0426.06
Expiration Date: 05/31/17
Approval Date: 05/24/12
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Cement -Adhesive -Coatings
Material: Elastomeric
SCOPE:
This approves GACO WESTERN ROOF COATING SYSTEMS" as a roof maintenance coatings
manufactured by Gaco Western LLC, as described in this Notice of Acceptance. This product has been
designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the
Florida Building Code.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials
GWI-007-02-01
ASTM D 6083
08/14/09
Technologies
Fed Spec TT-C-555B
GWI-002-02-201
ASTM D 6083
01/09/07
Fed Spec TT-C-555B
GWI-001-02-01
ASTM D 6694
04/10/07
Fed Spec TT-C-555B
GWI-004-02-01
ASTM D 6694
05/13/08
Fed Spec TT-C-555B
Underwriters Laboratories
Project 04NK27341
UL 790
02/01/05
Project 07NK02171
UL 790
03/13/07
Project 08NBO1503
UL 790
02/21/08
Factory Mutual Research Corp.
3023644
4470
02/02/07
MANUFACTURING LOCATION:
1. Waukesha, WI
PHYSICAL PROPERTIES OF COMPONENTS
Trade names:
A310OR Acrylic Top Coat
Thickness:
For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.13 gal/l00 ft2, an intermediate coat at a minimum rate of 1.13
gal/l00 ft', and a top coat at a minimum rate of 1.13 gal/100 ft.
For application of a recover coating over an existing acrylic roof apply a base
coat at a minimum rate of 1 gal/l00 ft', and a top coat at a minimum rate of
1 gal/100 ft.
Specifications:
ASTM D 6083
Description:
An acrylic white elastomeric quick set coating membrane applied to; spray
polyurethane foam roof systems and a recover of any existing acrylic roof.
Container Size:
5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 12-0426.06
Expiration Date: 05/31/17
Approval Date: 05/24/12
Page 2 of 4
H
Trade names:
S 1000 Top Coat
Thickness:
For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1.1 gal/100
ft2.
For application of a recover coating over an existing silicone roof apply a base
coat at a minimum rate of 1.1 gal/100 11:1, and a top coat at a minimum rate of
1.1 gal/100 W.
Specifications:
ASTM D 6694
Description:
A single component, air dried, silicone -based rubber elastomeric membrane
coating that is brush, roller or spray -applied. To be applied to spray polyurethane
foam roof systems and as a recover of any existing silicone roof coatings.
Container Size:
5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
Trade names: 5-2000 Solventless Silicone Basecoat/Top Coat
Thickness: For all applications apply 2 coats; a base coat at a minimum rate of .75 gal/100 ft
and a top coat at a minimum rate of .75 gal/100 ft2.
• Spray Polyurethane Foam Roof Systems
• Acrylic Coatings
• Galvanized Metal Roofs (in conjunction with E5320 2 part Epoxy Primer)
• Smooth Built Up Roof Systems (in conjunction with E5320 2 part Epoxy Primer)
• EPDM Single Ply Roof Systems (in conjunction with E5320 2 part Epoxy Primer)
• PVC Single Ply Roof Systems (in conjunction with E5320 2 part Epoxy Primer)
Specifications: ASTM D 6694
Description: A single component, moisture cured, silicone -based rubber elastomeric
membrane coating that is brush, roller or spray -applied to the roof covers listed
above.
Container Size: 5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 12-0426.06
Expiration Date: 05/31/17
Approval Date: 05/24/12
Page 3 of 4
Trade names: S 1600 Base Coat/Top Coat
Thickness: For application over spray polyurethane foam system apply a base coat at a
minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1 gal/100 ft.
For application of a recover coating over an existing silicone roof apply a base
coat at a minimum rate of I gal/100 fit, and a top coat at a minimum rate of
1 gal/100 ft.
Specifications: ASTM D 6694
Description: A single component, moisture cured, silicone -based rubber elastomeric
membrane coating that is brush, roller or spray -applied. To be applied to spray
polyurethane foam roof systems, galvanized metal, smooth surfaced built-up
(BUR) roofing, acrylic coating and any existing silicone roof coating..
Container Size: 1, 5 and 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. GACO WESTERN ROOF COATING SYSTEM shall not be applied in inclement weather
conditions.
3. GACO WESTERN ROOF COATING SYSTEM shall not be applied over asphaltic shingles,
metal shingles, fiber -cement shingles, quarry slate, cement or clay roofing tile, or wood shingles
or shakes.
4. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list any of the products listed herein as part of their roof assemblies Notice of
Acceptance. For applications over existing single ply, smooth or granulated BUR systems. Refer
applicable building code for requirements.
5. All products listed herein shall have an unannounced follow-up quality control program from an
approved listing agency. Follow up test results shall be made available to Miami -Dade County
Product Control upon request.
6. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear
the imprint or identifiable marking of the manufacturer's name or logo and following statement:
"Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control
Seal as shown below.
7. Change in materials, use, or manufacture of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
8. GACO WESTERN ROOF COATING SYSTEM shall only be applied by a factory trained and
certified applicators.
9. GACO WESTERN ROOF COATING SYSTEM shay be applied in accordance with
manufacturer's published application instructions.
END OF THIS ACCEPTANCE
NOA No.: 12-0426.06
Expiration Date: 05/31/17
Approval Date: 05/24/12
Page 4 of 4
0MDE
sie
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208
AFFAIRS (PERA) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/oera
Gaco Western LLC
1245 Chapman drive
Waukesha, WI 53186
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami —Dade County PERA —
Product Control Section to be used in Miami —Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product
Control Section (In Miami —Dade County) and/or the AHJ (in areas other than Miami —Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami —Dade
County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GACO WESTERN Polyfoam 273 over Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and
following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 08-0613.01 and consists of pages 1 through 4.
The submitted documentation was reviewed by Jorge L. Acebo.
PM1
A / 1,2
IVJ a 04 6.04
MIAM4DADE COUNTY 1 aH n Date: OS/31/17
,..., , Approval Date: 05/24/12
((( Page 1 of 4
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub -Category: Spray Applied Polyurethane Roof System
Materials: Polyurethane
Deck Type Concrete
Maximum Design Pressure - 435 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test Specifications
Product Description
Polyfoam 273
N/A
TAS 110
Polyurethane spray applied foam that
utilizes an HFC blowing agent intended
for roofing applications.
A3100R Acrylic Top
28 mil
ASTM D6083
An acrylic white elastomeric quick set
Coat
thickness
coating for application over spray
polyurethane foam roof systems.
S 1000 Top Coat
2.2 gallons per
ASTM D 6694
A white, gray or tan silicone -based
100/ft.Z
elastomeric coating for application over
spray polyurethane foam roof systems.
S 2000 Base Coat/Top 1.5 gallons per ASTM D 6694 A single component, solventless,
Coat 100/ft? moisture cured, silicone -based rubber
elastomeric coating for application over
spray polyurethane foam roof systems.
E5320 Epoxy Emulsion N/A proprietary Two component epoxy emulsion general
Primer purpose primer for spray applied
polyurethane foam to various substrates.
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test
Product
Product Dimensions Specifications
Description Manufacturer
Any Miami -Dade N/A As Required by
Roof coating for Generic.
County Approved
Miami -Dade
application over (with current PCA)
Roof Coating
County PCA
polyurethane spray
applied foam.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Reuort
Date
PRI Construction Materials
GWI-003-02-01
TAS 110
01/09/07
Technologies, LLC
GWI-002-02-201
ASTM D 6083/Fed Spec TT-C-555B
01/09/07
GWI-001-02-01
ASTM D 6694/Fed Spec TT-C-555B
04/10/07
GWI-004-02-01
ASTM D 6694/Fed Spec TT-C-555B
05/13/08
Underwriters Laboratories
Project 07NK02171
UL 790
03/13/07
Project 04NK27341
UL 790
02/01/05
Project 08NBO1503
UL 790
02/21/08
Factory Mutual
3023644
4470
02/02/07
NOA No.: 12-0426.04
MAMMADECouNTY Expiration Date: 05/31/17
,..., , Approval Date: 05/24/12
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 3: Concrete
Deck Description: 2500 psi structural concrete or concrete plank
System Type A: Sprayed polyurethane foam covered with an Approved Miami -Dade County roof
coating.
All General and System Limitations apply.
Deck Requirements: Concrete decks shall be in compliance with the Florida Building Code and
Roofing Application Standard RAS 109.
Surface
Preparation: Deck shall be primed in accordance with Gaco Western LLC recommendations,
and shall be free of loose dirt, grease, oil or other contaminants prior to priming
or foam application. Remove loose dirt or debris by use of compressed air,
vacuum or brooming. No washing shall be permitted. Oil, grease, release agents
or other contaminants shall be removed with proper cleaning solutions.
Primers shall be applied in accordance with their manufacturer's instructions.
All primers must be thoroughly dry and cured prior to foam application.
All joint openings in concrete decks that exceed 1/4 inch shall be grouted or
caulked.
Polyurethane Foam
Application: The polyurethane foam shall be applied uniformly over the entire surface at the
specified thickness in compliance with the requirements set forth Roofing
Application Standard RAS 109. The sprayed polyurethane foam shall be
feathered at the edges to produce a smooth transition.
Protective Coating
Application: Shall apply a Miami -Dade County approved roof coating with a current NOA
applied in accordance with the guidelines listed in the NOA.
Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars,
grease or other materials that will impair adhesion of the protective coverings.
Any damage or defects to the polyurethane foam surface shall be repaired prior
to the coating application. The coating shall be applied the same day as the foam
when possible. If more than 72 hours elapse prior to the application of the
coatings, the polyurethane foam shall be inspected for UV degradation.
Maximum Design
Pressure: -435 psf.
NOA No.: 12-0426.04
Expiration Date: 05/31/17
Approval Date: 05/24/12
Page 3 of 4
TABLE I
AMBIENT HUMIDITY APPLICATION LIMITS
SPRAYED POLYURETHANE FOAM
110
Gaeo Western LLC
Air Temp/ Humidity/ Dew Point Guideline
100
90
80
70
60
s0
40
30
Dew point and relative humidity forgiven dry bulb temperature.
45
67
40.5
50
70
45.5
55
72
50.5
60
75
55.5
4Airl
45
50
55
60
65
70
75
80
85
90
95
100
♦ Hui
67
70
72
75
78
80
78
75
70
64
58
50
f Deg
40.5
45.5
50.5
55.5
60.5
65.5
70
73.5
77
79.5
82
83
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product
i
2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the
dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall
monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log
shall be maintained at the job site and accessible to The Building Official.
3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in
accordance with Technical Roofing Solutions, Inc. published literature.
4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains
shall be a composite part of the roof system and shall be compatible with the foam and coating.
5. All attachment and sizing of perimeter Hailers, metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS 1 I I and the wind load requirements of applicable
building code.
6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
END OF THIS ACCEPTANCE
NOA No.: 12-0426.04
Expiration Date: 05/31/17
Approval Date: OS/24/12