Loading...
HomeMy WebLinkAboutNOAMI® DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE Gaeo Western LLC 1245 Chapman drive Waukesha, WI 5318f SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 w .miamidade.eov/oera SCANNED BY St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the A14J may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GACO WESTERN ROOF COATING SYSTEMS LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09-1109.03 and consists of pages 1 through 4. The submitted documentation was reviewed by Jorge L. Acebo. MAMMADE COUNTY ,...• 1 fOt No.:12-0426.06 Expiration Date: 05/31/17 Approval Date: 05/24/12 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Cement -Adhesive -Coatings Material: Elastomeric SCOPE: This approves GACO WESTERN ROOF COATING SYSTEMS" as a roof maintenance coatings manufactured by Gaco Western LLC, as described in this Notice of Acceptance. This product has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GWI-007-02-01 ASTM D 6083 08/14/09 Technologies Fed Spec TT-C-555B GWI-002-02-201 ASTM D 6083 01/09/07 Fed Spec TT-C-555B GWI-001-02-01 ASTM D 6694 04/10/07 Fed Spec TT-C-555B GWI-004-02-01 ASTM D 6694 05/13/08 Fed Spec TT-C-555B Underwriters Laboratories Project 04NK27341 UL 790 02/01/05 Project 07NK02171 UL 790 03/13/07 Project 08NBO1503 UL 790 02/21/08 Factory Mutual Research Corp. 3023644 4470 02/02/07 MANUFACTURING LOCATION: 1. Waukesha, WI PHYSICAL PROPERTIES OF COMPONENTS Trade names: A310OR Acrylic Top Coat Thickness: For application over spray polyurethane foam system apply a base coat at a minimum rate of 1.13 gal/l00 ft2, an intermediate coat at a minimum rate of 1.13 gal/l00 ft', and a top coat at a minimum rate of 1.13 gal/100 ft. For application of a recover coating over an existing acrylic roof apply a base coat at a minimum rate of 1 gal/l00 ft', and a top coat at a minimum rate of 1 gal/100 ft. Specifications: ASTM D 6083 Description: An acrylic white elastomeric quick set coating membrane applied to; spray polyurethane foam roof systems and a recover of any existing acrylic roof. Container Size: 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. NOA No.: 12-0426.06 Expiration Date: 05/31/17 Approval Date: 05/24/12 Page 2 of 4 H Trade names: S 1000 Top Coat Thickness: For application over spray polyurethane foam system apply a base coat at a minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1.1 gal/100 ft2. For application of a recover coating over an existing silicone roof apply a base coat at a minimum rate of 1.1 gal/100 11:1, and a top coat at a minimum rate of 1.1 gal/100 W. Specifications: ASTM D 6694 Description: A single component, air dried, silicone -based rubber elastomeric membrane coating that is brush, roller or spray -applied. To be applied to spray polyurethane foam roof systems and as a recover of any existing silicone roof coatings. Container Size: 5 and 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. Trade names: 5-2000 Solventless Silicone Basecoat/Top Coat Thickness: For all applications apply 2 coats; a base coat at a minimum rate of .75 gal/100 ft and a top coat at a minimum rate of .75 gal/100 ft2. • Spray Polyurethane Foam Roof Systems • Acrylic Coatings • Galvanized Metal Roofs (in conjunction with E5320 2 part Epoxy Primer) • Smooth Built Up Roof Systems (in conjunction with E5320 2 part Epoxy Primer) • EPDM Single Ply Roof Systems (in conjunction with E5320 2 part Epoxy Primer) • PVC Single Ply Roof Systems (in conjunction with E5320 2 part Epoxy Primer) Specifications: ASTM D 6694 Description: A single component, moisture cured, silicone -based rubber elastomeric membrane coating that is brush, roller or spray -applied to the roof covers listed above. Container Size: 5 and 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. NOA No.: 12-0426.06 Expiration Date: 05/31/17 Approval Date: 05/24/12 Page 3 of 4 Trade names: S 1600 Base Coat/Top Coat Thickness: For application over spray polyurethane foam system apply a base coat at a minimum rate of 1.1 gal/100 ft and a top coat at a minimum rate of 1 gal/100 ft. For application of a recover coating over an existing silicone roof apply a base coat at a minimum rate of I gal/100 fit, and a top coat at a minimum rate of 1 gal/100 ft. Specifications: ASTM D 6694 Description: A single component, moisture cured, silicone -based rubber elastomeric membrane coating that is brush, roller or spray -applied. To be applied to spray polyurethane foam roof systems, galvanized metal, smooth surfaced built-up (BUR) roofing, acrylic coating and any existing silicone roof coating.. Container Size: 1, 5 and 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire rating of this product. 2. GACO WESTERN ROOF COATING SYSTEM shall not be applied in inclement weather conditions. 3. GACO WESTERN ROOF COATING SYSTEM shall not be applied over asphaltic shingles, metal shingles, fiber -cement shingles, quarry slate, cement or clay roofing tile, or wood shingles or shakes. 4. The products listed herein are components of roof assemblies and are approved for use with roof assemblies that list any of the products listed herein as part of their roof assemblies Notice of Acceptance. For applications over existing single ply, smooth or granulated BUR systems. Refer applicable building code for requirements. 5. All products listed herein shall have an unannounced follow-up quality control program from an approved listing agency. Follow up test results shall be made available to Miami -Dade County Product Control upon request. 6. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. 7. Change in materials, use, or manufacture of any of the products listed herein shall be cause for termination of this Notice of Acceptance. 8. GACO WESTERN ROOF COATING SYSTEM shall only be applied by a factory trained and certified applicators. 9. GACO WESTERN ROOF COATING SYSTEM shay be applied in accordance with manufacturer's published application instructions. END OF THIS ACCEPTANCE NOA No.: 12-0426.06 Expiration Date: 05/31/17 Approval Date: 05/24/12 Page 4 of 4 0MDE sie MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/oera Gaco Western LLC 1245 Chapman drive Waukesha, WI 53186 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County PERA — Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GACO WESTERN Polyfoam 273 over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 08-0613.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Jorge L. Acebo. PM1 A / 1,2 IVJ a 04 6.04 MIAM4DADE COUNTY 1 aH n Date: OS/31/17 ,..., , Approval Date: 05/24/12 ((( Page 1 of 4 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Spray Applied Polyurethane Roof System Materials: Polyurethane Deck Type Concrete Maximum Design Pressure - 435 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specifications Product Description Polyfoam 273 N/A TAS 110 Polyurethane spray applied foam that utilizes an HFC blowing agent intended for roofing applications. A3100R Acrylic Top 28 mil ASTM D6083 An acrylic white elastomeric quick set Coat thickness coating for application over spray polyurethane foam roof systems. S 1000 Top Coat 2.2 gallons per ASTM D 6694 A white, gray or tan silicone -based 100/ft.Z elastomeric coating for application over spray polyurethane foam roof systems. S 2000 Base Coat/Top 1.5 gallons per ASTM D 6694 A single component, solventless, Coat 100/ft? moisture cured, silicone -based rubber elastomeric coating for application over spray polyurethane foam roof systems. E5320 Epoxy Emulsion N/A proprietary Two component epoxy emulsion general Primer purpose primer for spray applied polyurethane foam to various substrates. TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Dimensions Specifications Description Manufacturer Any Miami -Dade N/A As Required by Roof coating for Generic. County Approved Miami -Dade application over (with current PCA) Roof Coating County PCA polyurethane spray applied foam. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Reuort Date PRI Construction Materials GWI-003-02-01 TAS 110 01/09/07 Technologies, LLC GWI-002-02-201 ASTM D 6083/Fed Spec TT-C-555B 01/09/07 GWI-001-02-01 ASTM D 6694/Fed Spec TT-C-555B 04/10/07 GWI-004-02-01 ASTM D 6694/Fed Spec TT-C-555B 05/13/08 Underwriters Laboratories Project 07NK02171 UL 790 03/13/07 Project 04NK27341 UL 790 02/01/05 Project 08NBO1503 UL 790 02/21/08 Factory Mutual 3023644 4470 02/02/07 NOA No.: 12-0426.04 MAMMADECouNTY Expiration Date: 05/31/17 ,..., , Approval Date: 05/24/12 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 3: Concrete Deck Description: 2500 psi structural concrete or concrete plank System Type A: Sprayed polyurethane foam covered with an Approved Miami -Dade County roof coating. All General and System Limitations apply. Deck Requirements: Concrete decks shall be in compliance with the Florida Building Code and Roofing Application Standard RAS 109. Surface Preparation: Deck shall be primed in accordance with Gaco Western LLC recommendations, and shall be free of loose dirt, grease, oil or other contaminants prior to priming or foam application. Remove loose dirt or debris by use of compressed air, vacuum or brooming. No washing shall be permitted. Oil, grease, release agents or other contaminants shall be removed with proper cleaning solutions. Primers shall be applied in accordance with their manufacturer's instructions. All primers must be thoroughly dry and cured prior to foam application. All joint openings in concrete decks that exceed 1/4 inch shall be grouted or caulked. Polyurethane Foam Application: The polyurethane foam shall be applied uniformly over the entire surface at the specified thickness in compliance with the requirements set forth Roofing Application Standard RAS 109. The sprayed polyurethane foam shall be feathered at the edges to produce a smooth transition. Protective Coating Application: Shall apply a Miami -Dade County approved roof coating with a current NOA applied in accordance with the guidelines listed in the NOA. Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other materials that will impair adhesion of the protective coverings. Any damage or defects to the polyurethane foam surface shall be repaired prior to the coating application. The coating shall be applied the same day as the foam when possible. If more than 72 hours elapse prior to the application of the coatings, the polyurethane foam shall be inspected for UV degradation. Maximum Design Pressure: -435 psf. NOA No.: 12-0426.04 Expiration Date: 05/31/17 Approval Date: 05/24/12 Page 3 of 4 TABLE I AMBIENT HUMIDITY APPLICATION LIMITS SPRAYED POLYURETHANE FOAM 110 Gaeo Western LLC Air Temp/ Humidity/ Dew Point Guideline 100 90 80 70 60 s0 40 30 Dew point and relative humidity forgiven dry bulb temperature. 45 67 40.5 50 70 45.5 55 72 50.5 60 75 55.5 4Airl 45 50 55 60 65 70 75 80 85 90 95 100 ♦ Hui 67 70 72 75 78 80 78 75 70 64 58 50 f Deg 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 77 79.5 82 83 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product i 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Technical Roofing Solutions, Inc. published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter Hailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 1 I I and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). END OF THIS ACCEPTANCE NOA No.: 12-0426.04 Expiration Date: 05/31/17 Approval Date: OS/24/12 Page 4 of 4