WIND UPLIFT PRESSURE CALCULATIONS
Building "N'- South Tower
4160 N Hwy A-1-A
Ft. Pierce, FL - 34949
Structural Concrete
Low Slope
11
D
Enclosed
170 mph
Report No.:
Ale
�,� VN\J
Mean Roof Height
Roof Area (Approx.)
Roof Width
Perimeter Width
Parapet Height
Corner Zones
0.0 Slope H 12.0
q� = 0.00256 K� Kt Kd V2
qz Kz Krt
96.019 1.519 1.005
Kd V
0.85 170
0
Slope Angle°
ATRT-DP-16.009
140.0 Feet
19721 Sq.Ft.
100.0 Feet
10.0 Feet
1.0 Feet
10' x 10' Each
0.00
= q. (GCP - GCP,)
GCP
GCP;
-1.40
0.18 Field
-2.30
0.18 Perimeter
-3.20
0.18 Corner
Field
P1 UK.
-151.71 psf
P1 asd
-91.03 psf
Perimeter
P2Ut.
-238.13 psf
P2asd
-142.88 psf
Corner
P3 UK.
-324.55 psf
P3 asd
-194.73 psf
System Design Pressures
Field
P,
-91.03 psf
Perimeter
P2
-142.88 psf
Corner
P3
-194.73 psf
1 (#.05 —0,),?9
ST. LU TE COUNTY RUIZn1.NG DIVISION
REVIER'ED FOR C,9.1 LL4ti
DAI L I Ep 3Y (�
DATE
PLANS `D P1 IIT MU� KEPT ON JOB
OR NO INSPECTION NVILL BE INIADE.
THESE PLANS AND ALL PROPOSED WO;K
Proposed System ARE SUBJECT TO ANY CORRECTIONS
Product Approval REQUIRED BY FIELD INSPECTORS THAT
System Design Pressure
Max. Calculated Uplift Pressure-194.73psf . MAY BENECESSARY INORDEdTO:'
COMPLY WITH ALL APPLICABLE CODES.
These calculations have been done in accordance with ASCE 740, based on the information' provided by the
contractor. Any Miami -Dade County approved roof system over indicated deck with a system design pressure
greater than 194.73 psf may be used on the subject roof. The roof system must be installed in accordance
with the Florida Building Code and the roof system manufacturer's recommendations.
Sincerely
Fore sicN Engineering Consultants; Inc.
5 ,L)Ito
R. N. Sailappan, P.E. I
Principal Engineer
Florida Registration No. 46696